Report (3) 51
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
M t 4 c0 , am the general contractor or the owner-builder
at the following address:
Site Address: ( ceie 5 2rvo dattitig ger/or 1r
City: N iK,D
Permit#: -j'51-20 2,1 - 0-0 0 1 6
Subdivision/Lot#: R ovit 5 I Du?u=,( Pieji M/'
and/or /
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: Gd / - Date: 1 3 I 2-2-
eneral Con or or Owner-der--
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, T 4 jL.r M ur41Q,C , am the general contractor or the owner-builder
at the following address:
Site Address: I L tA 5 sru,ktv/Ali C1a rwr
City: .T� �(L D
Permit#: HI 2 d 2 l _ (1 8
Subdivision/Lot#: 120 A_e k 15 I
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code (ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
V The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
Joints lapped 12"at seams and
ending up the foundation walls 12".
Signature: / Date: /3 / Z Z-
General Contrac or Owner-Builder
I:1Building\Form\RES-MoistureBarrier.doc 09/13/2016
f
I
Form 640S 2017
Completion Certification—Site Inspection
New Homes Program—Single Family 1 t
of Oregon
To be completed by Verifier
CLEAResult is a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment Information
Incentive Payee Company Name: (Taylor Morrison Inc Portland Division I Is this payment redirected?: 'No
Builder or Company: Taylor Morrison Inc Portland Division Redirect to Name:
Verifier Payee Company Name: Performance Insulation and Energy Redirect Payee Com
Affordable Housing No
Solar Ready Builder Incentive: ISolar ReadyVerifier Inc
Site Information
Development RT 4 Eastndye II Innovate Lot errs � Axis ID:
��ktyi 44 IREM/Rafe®ID:
Address: j446 \\k0
Street Line 2 Multi-Family No City: Tigard State: OR Zip: 97224
Total conditioned area(sq.ft.): 1,228 House Volume: I 10.683 Housing Type: Townhouse inside
Number of Stories 11 Number of Bedrooms: 3
Foundation Type: Crawlspace
Electric Provider (Portland General Electric Gas Provider: NW Natural Gas
Solar installed Solar Installer Name/Company:
Blue shaded fields are required for EPS sheet
Verification Type Actual Model Equipment Details&Notes
Slab Perimeter Insulation R- 0.0 Slab Under Insulation
1 Insulation Framed Floor R- 30.0 Secondary Framed Floor R- 59.0
Above Grade Wall Insulation R- 23.0 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R-
Windows Windows U- 0.3 SHGC.I0.3 Total window area, 1420
Cooling Air Conditioning SEER: 0 Model#:
Primary Heating System Details AFUE: 95 Brand Lennox
Type: Gas Furnace HSPF: Model#: ML196UH070XE48B-51
Heating Fuel: Gas SEER:
Primary Heat
Source Comment: COP:
Location: Garage or op Outdoor Unit(for heat pumps)
ECM: No Model#: I
AHRI Certificate:4805339 #of Systems I1
Gallons: I Brand: BradfordWhite
Water Heater Type Heat Pump EF: I Model#: RE250T6-1NCWW
Water Heating Fuel Electric Location: !Garage or op AHRI Certificate:9952297
Ducts and Duct Location Unconditioned %ducts inside. Aigia1 ATo Duct Leakage(CFM)@ 50Pa:
Testing
Infiltration Air Changes per Hour(ACH)@ 50Pa: 4.03
Ventilation Ventilation Type HRV/ERV Model:
Supply Side-Air Cycler Airflow measured or why untestable? 'Roof Termination
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: i,di 2 o z I , d Do ri es Jurisdiction:
Site Address: L.462c A/ /A`i Oa 74 c7-- sr.
Subdivision/Lot#: /o � I S
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: jidleZ/)..----- Date: l 3/l z
Owner/Gen alQf Con• . • • ui•s•".•ed Agent
Print Name: jefo 77-- � G iL JuiV&3?
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
1:1Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08