Specifications anrrr.r..rr P202L4300S7 Y.Z,Zg AU OFFICE COPY RECEIVED BAR 2 2022 CITY OF TIGARD fv BUILDING DIVISION FIRefirtoi4 Oki STRUCTURAL CALCULATIONS for Voluntary Seismic Strengthening PacTrust Busines Center- Building 0 7228 SW Durham Road Tigard, Oregon for Pacific Realty Associates, LP 15350 SW Sequoia Parkway, Suite 300 Portland, Oregon 97224 by MHP, Inc. Structural Engineers -€ Long Beach, California O PR pe,_ <2r z, x d February 9, 2022 ,111r MHP JN: 17-0192-00 At. , r e c �.... .. ........ .,..r ,...e...,�......... IVHJ III Tkiif TURAt. fNC.iNFPof CALCULATION SHEET MilSUBJECT. Voluntary Seismic Strengthening DATE: Feb-22 JOB NO: 17-0192 NIA. ���r�uRe� c�ua,niFva< 7228 SW Durham Road BY: SHEET: Table of Contents Section Page No. GENERAL Scope of Work 1.1 USGS Ground Motion Data 1.2- 1.3 STRUCTURE DESIGN: Wall Anchorage N-S 2.1 Hilti Anchor Check 2.2-2.6 Wall Anchorage E-W 2.7 Hilti Anchor Check 2.8-2.12 N-S Subdiaphragm Analysis 3.1 E-W Subdiaphragm Analysis 3.2 CALCULATION SHEET rtll..I SUBJECT: Voluntary Seismic Strengthening DATE; Feb-22 JOB NO: 17-0192 c ::r TIN A! cvcivcc:p� 7228 SW Durham Road BY; SHEET; 1.1 Scope of Work This project is a voluntary seismic strengthening of the wall anchorage systems to reduce the potential for structural damage in an earthquake.The retrofit wall anchorage systems are designed to meet the Basic Performance Objective of Existing Buildings(BPOE)per the requirements of ASCE 41-17 Seismic Evaluation and Retrofit of Existing Buildings. The BPOE is defined as a Life Safety performance level during a BSE-1E seismic event [the BSE-1E is defined as an earthquake hazard with a probability of exceedance of 20 percent in a 50-year exposure period—alternately defined as having an average return period of 225-years]and a a Collapse prevention performance level during a BSE-2E seismic event[the BSE-2E is defined as an earthquake hazard with a probability of exceedance of 5 percent in a 50- year exposure period—alternately defined as having an average return period of 975-years] • 2/9/22,7:50 AM ATC Hazards by Location 1.2 alt 'Hazards by Location Search Information Address: 7228 SW Durham Rd,Tigard,OR 97224,USA 170 ft and W Coordinates: 45.39802359999999,-122.751954 Hillsbr3 t,' a oave Elevation: 170 ft Timestamp: 2022-02-09T15:50:20.160Z a t ) h l r rl d��ir, ielr€, f. Hazard Type: Seismic 1.. Reference Document: ASCE41-17 Go gle Map data 02022 Google Site Class: D-default Custom Probability: Horizontal Response Spectrum -Hazard Level BSE-2N Sa(g) 1.00 0.80 0.60 0.40 0.20 0.00 0 5 10 15 Period(s) Hazard Level BSE-2N Name Value Description SsUH 0.96 Factored uniform-hazard spectral acceleration(2%probability of exceedance in 50 years) CRs 0.886 Coefficient of risk(0.2s) SsRT 0.85 Probabilistic risk-targeted ground motion(0.2s) SsD 1.5 Factored deterministic acceleration value(0.2s) Ss 0.85 MCER ground motion(period=0.2s) Fa 1.2 Site amplification factor at 0.2s Sxs 1.02 Site modified spectral response(0.2s) 4 BSE-2N Si UH 0.45 Factored uniform-hazard spectral acceleration(2%probability of exceedance in 50 years) CR1 0.866 Coefficient of risk(1.0s) S1RT 0.39 Probabilistic risk-targeted ground motion(1.0s) Si D 0.6 Factored deterministic acceleration value(1.0s) Si 0.39 MCER ground motion(period=l.0s) F� 1.91 Site amplification factor at 1.0s Sxt 0.744 Site modified spectral response(1.0s) Hazard Level BSE-1 N Name Value Description Sxs 0.68 Site modified spectral response(0.2s) 4 BSE-1 N Sxt 0.496 Site modified spectral response(1.0s) Hazard Level BSE-2E https://hazards.atcouncil.org/#/seismic?lat=45.39802359999999&Ing=-122.751954&address=7228 SW Durham Rd%2C Tigard%2C OR 97224%2C U... 1/2 2/9/22,7:50 AM ATC Hazards by Location 1.3 Name Value Description Ss 0.609 MCER ground motion(period=0.2s) Fa 1.313 Site amplification factor at 0.2s SXS 0.799 Site modified spectral response(0.2s) 4 -- ---- BSE-2E Si 0.276 MCER ground motion(period=1.0s) Fv 2.049 Site amplification factor at 1.0s Ski 0.565 Site modified spectral response(1.0s) Hazard Level BSE-1 E Name Value Description Ss 0.233 MCER ground motion(period=0.2s) Fa 1.6 Site amplification factor at 0.2s SX8 0.372 Site modified spectral response(0.2s) 4 BSE-1 E Si 0.085 MCER ground motion(period=1.0s) Fv 2.4 Site amplification factor at 1.0s SX1 0.204 Site modified spectral response(1.0s) TL Data Name Value Description TL 16 Long-period transition period(s) The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process.Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are provided by the U.S.Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct,ATC and its sponsors and contributors assume no responsibility or liability for its accuracy.The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy,suitability and applicability by engineers or other licensed professionals.ATC does not intend that the use of this information replace the sound judgment of such competent professionals,having experience and knowledge in the field of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use.Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. LIFE SAFETY Sxs (BSE-1 E) = 0.372 Sxs (minimum) = 0.75*Sxs (BSE-1 N) = 0.75*0.68 = 0.510 + GOVERNS COLLAPSE PREVENTION Sxs (BSE-2E) = 0.799 4 -- GOVERNS Sxs (minimum) = 0.75*Sxs (BSE-1N) = 0.75*1.02 = 0.765 https://hazards.atcouncil.org/#/seismic?lat=45.39802359999999&Ing=-122.751954&address=7228 SW Durham Rd%2C Tigard%2C OR 97224%2C U... 2/2 , CALCULATION SHEET SUBJECT. 7228 SW Durham Road DATE: Feb-22 foe Ho: 17-0192 ;TRIJCT27RAi. ENf.,24=sec Wall Anchorage N-S BY: SHEET: 2.1 Wall Anchorage N-S Basic Performance Objective of Existing Buildings(BPOE)per ASCE41-17 dwap= 6.5 in wwa1l= 150 pcf htr,b= 15.001 ft —1 Wo= 1219 plf hp= 2.5 ft Lf= 275 ft (Minimum Diaphragm Length) / ka=1+Lf/100= 3.75 (ASCE 41-17,Eq.7-11) ♦ ..I use ka= 2 (ka max=2) Fo.roof za= 24.75 ft (Height of Anchorage) _0. kh=1/3(1+2*(za/hn))= 1 (ASCE 41-17,Eq.7-12) BSE-1E hazard level(Life Safety) —* Sxs= 0.51 g (See Attached USGS Report) X= 1.30 (ASCE 41-17,Tbl 7-1) hp= 24.8 ft Fp=0.4 Sos kakh X Wp= 646 plf (ASCE 41-17,Eq.7-9) —p Fp,min=0.2 ka X Wp= 634 plf (ASCE 41-17,Eq.7-10) BSE-2E hazard level(Collapse Prevention) —0. Sas= 0.80 g (See Attached USGS Report) X= 0.90 (ASCE 41-17,Tbl 7-1) Fp=0.4 Sps kakh X Wp= 701 plf (ASCE 41-17,Eq.7-9) _-p Fp,min=0.2 ka X Wp= 439 plf (ASCE 41-17,Eq.7-10) Fp,„= 701 plf n Anchor spacing(s)= 7 ft (Max Effective) QUF=(Fp max*s)= 4908 lbf (ASCE 41-17,Eq.7-35) Holdown (Member t): HDUS-SDS2.5(3") Number of Holdowns: 1 Kf= 3.32 (Strength Conversion Factor-NDS 2015 TBL 11.3.1&N1) FHoldown= 1 x 5645 lbf= 5645 lbf (Simpson Strong Tie) Qci=0.85*(Fholdown/1.6)*Kf = 9956 Ibf Q« > QUF O.K. (ASCE 41-13,Eq. 7-37) DCR= 0.49 (Demand Capactiy Ratio) Use: HDUS-SD52.5 at 7 ft O.C. Anchor Embedment: QuF=(F0 max*s)= 4908 Ibf 4)= 1 (Ultimate Strength) Anchor Diameter= 5/8 in Steel Strength(Nsa)= 13110 lbf (Profis) Min Embedment= 5 in (Profis) Bond Strength(0.75*Nag)= 7047 lbf (Profis) Breakout Strength(0.75*Ncbg)= 6030 lbf <---QcI (Profis) QCL > QUF O.K. 5/8"Dia.with HIT-RE 500 V3 Epoxy DCR= 0.81 Use: Min Embedment 5" (See attached Profis Calcualtion for Threaded Rod in Concrete) EMIR 2.2 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 1 Address: Specifier: Phone I Fax: I E-Mail: Design: Concrete-Feb 8,2022 Date: 2/8/2022 Fastening point: Specifier's comments: Wall Anchor - N/S 1 Input data moon � - - Anchor type and diameter: HIT-RE 500 V3+HAS-V-36(ASTM F1554 Gr.36)5/8 Item number: 2198024 HAS-V-36 5/8"x6"(element)/2123401 HIT-RE 500 V3(adhesive) Effective embedment depth: hef,act=5.000 in.(het,limit=-in.) Material: ASTM F1554 Grade 36 Evaluation Service Report: ESR-3814 Issued I Valid: 3/1/2021 11/1/2023 Proof: Design Method ACI 318-19/Chem Stand-off installation: Profile: Base material: cracked concrete,2500,fc'=2,500 psi;h=6.500 in.,Temp.short/long:32/32°F Installation: hammer drilled hole,Installation condition:Dry Reinforcement: tension: not present,shear:not present;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Geometry[in.]&Loading[Ib,in.lb] 4 44 Design loads Sustained loads 4 6."—b ) \ X \ Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 1 2.3 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 2 Address: Specifier: Phone I Fax: I E-Mail: Design: Concrete-Feb 8,2022 Date: 2/8/2022 Fastening point: 1.1 Design results Case Description Forces[Ib]/Moments[in.lb] Seismic Max. Util.Anchor[%] 1 Combination 1 N=4,908;Vx=0;Vy=0; no 94 Mx=0;My=0;Mz=0; 2 Load case/Resulting anchor forces Anchor reactions[Ib] Tension force: (+Tension,-Compression) Anchor Tension force Shear force Shear force x Shear force y 1 4,908 0 0 0 max.concrete compressive strain: -[°%a] max.concrete compressive stress: -[psi] resulting tension force in(x/y)=(0.000/0.000): 0[lb] resulting compression force in(x/y)=(0.000/0.000): 0[Ib] 3 Tension load Load Nun[Ib] Capacity+ N„[Ib] Utilization(3N=Nua/. N„ Status Steel Strength* 4,908 9,832 50 OK Bond Strength** 4,908 6,108 81 OK Sustained Tension Load Bond Strength* N/A N/A N/A N/A Concrete Breakout Failure** 4,908 5,226 94 OK *highest loaded anchor **anchor group(anchors in tension) Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 2 1411111( 2.4 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 3 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete-Feb 8,2022 Date: 2/8/2022 Fastening point: 3.1 Steel Strength Nsa =ESR value refer to ICC-ES ESR-3814 Nsa >Nua ACI 318-19 Table 17.5.2 Variables Ase,N[in.2] futa[psi] 0.23 58,000 Calculations Nsa[lb] 13,110 Results Nsa[lb] steel • Nsa[lb] Nua[lb] 13,110 -0.7 0 9,832 4,908 1.0 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 3 IM' 2.5 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 4 Address: Specifier: Phone I Fax: I E-Mail: Design: Concrete-Feb 8,2022 Date: 2/8/2022 Fastening point: 3.2 Bond Strength Na = (AN Aa) N U1 ed,Na 'cp,Na Nba ACI 318-19 Eq. (17.6.5.1a) ao Na >Nua ACI 318-19 Table 17.5.2 ANa see ACI 318-19,Section 17.6.5.1,Fig. R 17.6.5.1(b) ANao =(2 CNa)2 ACI 318-19 Eq.(17.6.5.1.2a) CNa =10 da ;armor ACI 318-19 Eq.(17.6.5.1.2b) 1100 tired,Na =0.7+0.3 (Cayin) <1.0 ACI 318-19 Eq. (17.6.5.4.1b) CNa 4'cp,Na =MAX(Ca�min CNa) <1.0 ACI 318-19 Eq. (17.6.5.5.1b) Cac Cac Nba =X a•Tk,c•f<•da• her ACI 318-19 Eq. (17.6.5.2.1) Variables 1 1 k,c,uncr[psi] da[in.] hef[In.] ca,min[in.] overhead T k,c[psi] 2,210 0.625 5.000 6.000 1.000 1,260 cac[in.] a 11.692 1.000 Calculations cNa[in.] AN.[in.2] ANao[in.2] 'I'ed,Na 8.819 261.37 311.09 0.904 Vr cp,Na Nba[Ib] 1.000 12,370 Results Na[lb] 4)bond 4) Na[Ib] Nua[Ib] 9,396 —84 58— 6,108 4,908 1.0 0.75*Na = 0.75*9,396# = 7,047# Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 4 111411611111111r1'',° 2.6 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 5 Address: Specifier: Phone I Fax: I E-Mail: Design: Concrete-Feb 8,2022 Date: 2/8/2022 Fastening point: 3.3 Concrete Breakout Failure A Ncb = (ANco) lh ed,N 'c,N t1cp,N Nb ACI 318-19 Eq.(17.6.2.1 a) Nab >Nua ACI 318-19 Table 17.5.2 ANC see ACI 318-19,Section 17.6.2.1, Fig.R 17.6.2.1(b) ANco =9 her ACI 318-19 Eq.(17.6.2.1.4) tlf ed,N =0.7+0.3 (Ca,min/ <1.0 ACI 318-19 Eq.(17.6.2.4.1 b) 1.5het t(r cpN =MAX(CaJmin 1.5he,1 1.0 ACI 318-19 Eq.(17.6.2.6.1b) Ali: Cac f Nb =kc X.a Vfc he.5 ACI 318-19 Eq.(17.6.2.2.1) Variables 1 het[in.] Ca,min[in.] tV c,N Cac[in.] kc A a fa[psi] 5.000 6.000 1.000 11.692 17 1.000 2,500 Calculations ANC[in.2] ANcO[in.2] 41 ed,N t"Jcp,N Nb[Ib] _ 202.50 225.00 0.940 1.000 9,503 Results Nth[Ib] concrete 41 Ncb[Ib] Nua[Ib] 8,040 "15'e0 5,226 4,908 1.0 0.75*Ncbg = 0.75*8,040# = 6,030# Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 5 CA Mill a SUBJECT 72285W Durham Road Date: Feb-22 foe No:LCULATION SHEET 17-0192 <TAI,Tc,u,:: -ua:ucra` Wall Anchorage E-W BY: SHEET: 2.7 Wall Anchorage E-W Basic Performance Objective of Existing Buildings(BPOE)per ASCE41-17 dwall= 6.5 in wwa11= 150 pcf htrib= 12.4 ft Wp= 1008 plf hp= 0 ft Lf= 100 ft (Minimum Diaphragm Length) ,4—_ ka=1+Lf/100= 2 (ASCE 41-17,Eq.7-11) • use ka= 2 (ka max=2) Fo,roof za= 24.8 ft (Height of Anchorage) kh=1/3(1+2*(za/hn))= 1 (ASCE 41-17,Eq.7-12) BSE-1E hazard level(Life Safety) S0,= 0.51 g (See Attached USGS Report) X= 1.30 (ASCE 41-17,Tbl 7-1) fin= 24.8 ft Fp=0.4 Sps kakh X Wp= 534 plf (ASCE 41-17,Eq.7-9) Fp.min=0.2 ka X Wp= 524 plf (ASCE 41-17,Eq.7-10) BSE-2E hazard level(Collapse Prevention) S%5= 0.80 g (See Attached USGS Report) X= 0.90 (ASCE 41-17,Tbl 7-1) Fp=0.4 SEA kakh X Wp= 580 plf (ASCE 41-17,Eq.7-9) Fp,min=0.2 ka X Wp= 363 plf (ASCE 41-17,Eq.7-10) • Fp max= 580 plf A Anchor spacing(s)= 8 ft Quf=(Fp max*s) = 4637 Ibf (ASCE 41-17,Eq.7-35) Holdown (Member t): HDU2-SDS2.5(3") Number of Holdowns: 2 Kf= 3.32 (Strength Conversion Factor-NDS 2015 TBL 11.3.1&N1) FHoldown= 2 x 3075 lbf= 6150 lbf (Simpson Strong Tie) Clot=0.85*(Fhomown/1.6)*Kf= 10847 Ibf Q. > QUr O.K. (ASCE 41-13,Eq. 7-37) DCR= 0.43 (Demand Capactiy Ratio) Use: HDU2-SDS2.5 EA Side at 8 ft O.C. Anchor Embedment: Qur=(Fp max*s)= 4637 Ibf 0= 1 (Ultimate Strength) Anchor Diameter= 5/8 in Steel Strength(Nsa)= 13110 lbf (Profis) Min Embedment= 5 in (Profis) Bond Strength(0.75*Nag)= 9095 Ibf (Profis) Breakout Strength(0.75*Ncbg)= 8090 lbf <---QcI (Profis) QCL > Quf O.K. 5/8"Dia.with HIT-RE 500 V3 Epoxy DCR= 0.57 Use: Min Embedment 5" (See attached Profis Calcualtion for Threaded Rod in Concrete) � oir rs 2.8 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 1 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete-Feb 8, 2022 Date: 2/8/2022 Fastening point: Specifier's comments: Wall Anchor- E/W 1 Input data 410,041 Anchor type and diameter: HIT-RE 500 V3+HAS-V-36(ASTM F1554 Gr.36)5/8 Item number: 2198025 HAS-V-36 5/8"x8"(element)/2123401 HIT-RE 500 V3(adhesive) Effective embedment depth: hef,act=5.000 in.(hef,limit=-in.) Material: ASTM F1554 Grade 36 Evaluation Service Report: ESR-3814 Issued I Valid: 3/1/2021 11/1/2023 Proof: Design Method ACI 318-19/Chem Stand-off installation: eb=0.000 in. (no stand-off);t=0.500 in. Anchor platen: Ix x ly x t=9.125 in.x 4.000 in.x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete,2500,fb'=2,500 psi;h=6.500 in.,Temp. short/long:32/32°F Installation: hammer drilled hole,Installation condition:Dry Reinforcement: tension: not present,shear:not present;no supplemental splitting reinforcement present edge reinforcement: none or<No.4 bar R-The anchor calculation is based on a rigid anchor plate assumption. Geometry[in.]&Loading[lb,in.lb] 4 44,Design loads Sustained loads kiNN Aitfth as 400 z • • Y O X Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 1 2.9 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 2 Address: Specifier: Phone I Fax: I E-Mail: Design: Concrete-Feb 8,2022 Date: 2/8/2022 Fastening point: 1.1 Design results Case Description Forces[Ib]/Moments[in.lb] Seismic Max. Util.Anchor[%] 1 Combination 1 N=4,637;Vx=0;Vy=0; no 67 Mx=0;My=0;MZ=0; 2 Load case/Resulting anchor forces Anchor reactions[Ib] Tension force:(+Tension,-Compression) • Anchor Tension force Shear force Shear force x Shear force y y 1 2,319 0 0 0 2 2,319 0 0 0 02 O Ec1 Tension max.concrete compressive strain: -[%o] max.concrete compressive stress: -[psi] resulting tension force in(x/y)=(0.000/0.000): 4,637[Ib] resulting compression force in(x/y)=(0.000/0.000): 0[lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load N.[Ib] Capacity+ N„[Ib] Utilization 13N=N„a/+ N„ Status Steel Strength* 2,319 9,832 24 OK Bond Strength** 4,637 7,882 59 OK Sustained Tension Load Bond Strength* N/A N/A N/A N/A Concrete Breakout Failure** 4,637 7,011 67 OK *highest loaded anchor **anchor group(anchors in tension) Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 2 2.10 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 3 Address: Specifier: Phone I Fax: I E-Mail: Design: Concrete-Feb 8,2022 Date: 2/8/2022 Fastening point: 3.1 Steel Strength Nsa =ESR value refer to ICC-ES ESR-3814 Nsa >Nua ACI 318-19 Table 17.5.2 Variables Aso lin.z] futa[psi] 0.23 58,000 Calculations Nsa[Ib] 13,110 Results Nsa[Ib] 4i steel $ Nsa[Ib] Nua[Ib] 13,110 9,832 2,319 1.0 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 3 s ..... w, 2,11 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 4 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete-Feb 8,2022 Date: 2/8/2022 Fastening point: 3.2 Bond Strength Nag = (ANop) lil ect,Na ec2,Na� ed,NaW I cp,Na Nba ACI 318-19 Eq. (17.6.5.1b) 4) Nag >Nua ACI 318-19 Table 17.5.2 ANa see ACI 318-19, Section 17.6.5.1, Fig. R 17.6.5.1(b) ANao =(2 CNa)2 ACI 318-19 Eq. (17.6.5.1.2a) Chia =10 da V Z 100 uncr ACI 318-19 Eq. (17.6.5.1.2b) 1 ec,Na = (1 + eN/ <1.0 ACI 318-19 Eq. (17.6.5.3.1) cNa t'ed,Na =0.7+0.3 (Cy) <1.0 ACI 318-19 Eq.(17.6.5.4.1 b) CNa • 14/cp,Na =MAX(Ca-1L CNa) 1.0 ACI 318-19 Eq.(17.6.5.5.1b) Cac Cac Nba =X a• tk,c• n •da• her ACI 318-19 Eq.(17.6.5.2.1) Variables f 7 7 k,c,uncr[psi] da[in.] he,[in.] Ca,min[in•] aoverhead tk,c[Psi] 2,210 0.625 5.000 6.000 1.000 1,260 ec1 N[in.] earl[in.] Cac[in.] a 0.000 0.000 11.692 1.000 Calculations CNa[in] ANa[in.2] ANao[in.2] LV ed,Na 8.819 337.32 311.09 0.904 111 ec1,Na wec2,Na cp,Na Nba[Ib] 1.000 1.000 1.000 12,370 Results A Na4[Ib] w bond 4) Nau[Ib] N.[Ib] 12,127 '0'9e9'— 7,882 4,637 1.0 0.75*Nag = 0.75*12,127# = 9,095# Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 4 2.12 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 5 Address: Specifier: Phone I Fax: I E-Mail: Design: Concrete-Feb 8,2022 Date: 2/8/2022 Fastening point: 3.3 Concrete Breakout Failure Ncbg = (A`O) Vf ec,N Wed,N tvc,N ivcp,N Nb ACI 318-19 Eq.(17.6.2.1b) Ncbg >N.a ACI 318-19 Table 17.5.2 ANc see ACI 318-19,Section 17.6.2.1, Fig.R 17.6.2.1(b) ANco =9 het ACI 318-19 Eq.(17.6.2.1.4) 1 t�ec,N = (1 +2e) <1.0 ACI 318-19 Eq.(17.6.2.3.1) 3het yi ed,N =0.7+0.3 (Ca,mint) <1.0 ACI 318-19 Eq.(17.6.2.4.1 b) 1.5h cp,N =MAX(Cayin 1.5het) <1.0 ACI 318-19 Eq.(17.6.2.6.1 b) �Cac Cac Nb =kc Vfc het5 ACI 318-19 Eq.(17.6.2.2.1) Variables hef[in.] ecl,N[in.] ec2 N[in.] ca,min[in.] w c,N 5.000 0.000 0.000 6.000 1.000 Cac[in.] kc X a tc[psi] 11.692 17 1.000 2,500 Calculations AN,[in.2] Awn[in.2] ecl,N tltec2,N tved,N tvcp,N Nb[Ib] 271.69 225.00 1.000 1.000 0.940 1.000 9,503 Results Ncbg[Ib] concrete 4) Ncbg[Ib] N.[lb] 10,787 0.050 7,011 4,637 1.0 0.75*Nag = 0.75*10,787# = 8,090# Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 5 CALCULATION SHEET Mil a SUBJECT: 7228 SW Durham Road DATE: Feb-22 JOB NO: 17-0192 ��:�.T„� E �ntr,,N�FE< N-S Subdiaphragm Analysis BY: SHEET: 3.1 N-S Subdiaphragm Analysis Fp max= 701 plf Continuity Tie Spacing(s)= 25 ft Subdiaphragm Depth(d)= 12 ft Aspect Ratio(s/d)= 2.083 OK (3.0 max) Our=(Fpmax*S/2)/d= 730 plf (ASCE 41-17,Eq.7-35) Existing Plwyood Thickness and Nailing Pattern(Boundary&Cont.Edges/Other Edges/Field): 19/32"Ply w/10d @ 4/6/12(2x) Nominal Unit Shear Capacity(v)= 850 plf (NDS Table 4.2A) Cd= 1 (Duration Factor) QCL=v/Cd= 850 plf Use: 12 ft long x 25 ft wide subdiaphragm QCL > QUF O.K. DCR= 0.859 Continuity Tie Fpmax= 701 plf Continuity Tie Spacing(s)= 25 ft (effective spacing) QDE=(Fp max#s)= 17530 lbf Continuity Tie Force CHECK(E)HCCTA HINGE CONNECTION Tallow=14,850#(ASD FORCE LEVEL PER SIMPSON CATALOGUE) Kf=3.32(STRENGTH CONVERSION FACTOR-NDS 2015 TBL 11.3.1 &N1) Qcl=0.85*(Tallow/1.6)*Kf=26,191#(DCR:0.67) (E)HCCTA OK CALCULATION SHEET IdIuu1 SUBJECT: 7228 SW Durham Road DATE: Feb-22 JOB NO. 17-0192 ,aurr JH J ENC E-W Subdiaphragm Analysis BY: SHEET: 3.2 E-W Subdiaphragm Analysis Fp max= 580 plf Continuity Tie Spacing(s)= 24 ft Subdiaphragm Depth(d)= 25 ft Aspect Ratio(s/d)= 0.96 OK (3.0 max) Our=(FD ax*s/2)/d= 278 plf (ASCE 41-17,Eq.7-35) Existing Plwyood Thickness and Nailing Pattern(Boundary&Cont.Edges/Other Edges/Field): 19/32"Ply w/l0d @ 4/6/12(2x) Nominal Unit Shear Capacity(v)= 850 plf (NDS Table 4.2A) Cd= 1 (Duration Factor) QCL=v/Cd= 850 plf Use: 25 ft long x 24 ft wide subdiaphragm QCL > QUF O.K. DCR= 0.327 Continuity Tie Fp max= 580 plf Continuity Tie Spacing(s)= 20 ft (effective spacing) Our=(Fpmax*s) = 11592 lbf Continuity Tie Force USE SIMPSON CMST12 STRAP Tallow=9,215#(ASD FORCE LEVEL PER SIMPSON CATALOGUE) TLrfd-13,850#w/phi=0.90(PER SIMPSON) Qcl= 13,850#/0.90= 15,389#(DCR:0.75) CMST12 STRAP OK