Plans . . GENERAL NOTES o c o 0 0 0 A. THIS PROJECT CONSISTS OF THE INSTALLATION OF THE NEW PENDENT FIRE SPRINKLERS TO 1710 - _ CONFORM TO THE NEW WALL AND CEILING LAYOUT FOR TENANT IMPROVEMENT. I ❑ i I B. COSCO FIRE PROTECTION WORK TO BEGIN AT THE EXISTING OVERHEAD SYSTEM UTILIZING EITHER kiECEIVED J- _-U_Ia -E- -- MECHANICAL-T'SOR EXISTING 1"OUTLETS. FEB1 --� __ -- -�-- C. ALL SPRINKLERS,HANGERS AND PIPING TO BE DESIGNED AND INSTALLED PER NFPA 13(2016 E 2 2022 -______ 7 -� r�- - - - 1 0 EDITION). OF TIGARD I -• - - 1 BUILDING DIVISION - - 1 D. ALL NEW FIRE PROTECTION PIPING IS 1"SCH-40 BLACK STEEL PIPE. -i_-- E. NEW PENDENT SPRINKLERS SPACING LIMITED TO 225sqft. `r-- I L I 1 l-- Q9 —121t F. ALL ELECTRICAL CONNECTIONS AND WORK IS BY OTHERS. -=_ -� - I II— ~:ILL, ^Cii G.ALL MATERIAL TO BE I.A.W.THE REQUIREMENTS OF NFPA 13(2016 EDITION)FOR FIRE SPRINKLER 0011 = i'�' USE. - --H. PIPING TO PENDENT SPRINKLERS SHALL BE ACCOMPLISHED BY USE OF THE VICFLEX®BRANDC - o 41111 FLEXIBLE SPRINKLER DROP. VICFLEX DROP CRITERIA:48"MODEL AH2-HYDRAULIC EQ.LENGTH 431 4tou - 7,,OF:21ft,MAX 4 90"BENDS(MINIMUM 3"BEND RADIUS AS PER UL GUIDELINES). I 1®1 ��� ---- -- __ ����% I. PENDENT SPRINKLERS INSTALLED WITHIN ACOUSTICAL CEILINGS SHALL BE LOCATED IN THE CENTER OR QUARTER-POINT OF THE TILE. o ADD TWO (2) NEW PENDENT • SPRINKLERS IN NEW OFFICE v' VICFLEX DROP FROM SIDE OUTLET WITH 1"SCR 40 PRIMARY ARMOVER d DROP SPRINKLER BRANCHLINE OR MAIN PIPING 1 1' � VICFLEX DROP FROM BOTTOM VICFLEX DROP OUTLET WITH 1"SCH.40 ' FROM BOTTOM ! 1 PRIMARY DROP 0 0OUTLET rat es' '"_, • VICFLEX CEILING C. BASIC CEILING 1' DEVICE BRACKET,TYP. e? ` CITY OF TIGARD • En A Approved ti` Contitionaily Approved r t l e For only the work as described in: ACOUSTIC OR GYP BOARD PERMIT NO. F( .Z C/22-Oo2_ CEILING SYSTEM (� See Letter to: Follow [ I ._ PENDENT SPRINKLER TYP BASIC CEILING Attach DEVICE Job Asir •Soo I SN/f WJ i KEP- sr PLAN VIEW TYPICAL VICFLEX SPRINKLER DROP CONNECTION BY: Date:01/O9/22_ SCAT F• NTS %4'= 1'-0" REV DATE DESCRIPTION Sprinkler Legend SHEET NAME Symbol Manufacturer SIN Model Quantity_K-Factor Type Size Response Finish Temperature TENANT IMPROVEMENT COSCO VIMnq VKIN Model 2 Sr PendentType Standard Chrome 16eF •M •• Total•2 ♦••••••♦ FIRE SPRINKLER PLAN • ••••••• '••••' Fire Protection PROJECT MARKET CRAFT Fire Protection and Life Safety Specialists Portland & Vancouver Office PROJECT 8001 SW HUNZIKER STREET NUMBER 2201-306 •' 4 2501 SE Columbia Way, Suite 100 TIGARD, OREGON 97223 « 2a ''« DESIGNER DATE D.FLUIT 02.02.22 +`�`„,. . Vancouver, Washington 98661 GENERAL CONTRACTOR slu Goya SIMoss www.coscofire.com YORKE&CURTIS INC. License No: SHEET WA #COSCOFPI 1ONN 4480 SW 101stAVE, BEAVERTON, OREGON 97005 OR #67508 I OF I FP-1