Report (/' .�zrz,rs>463 RECEIVED //2 / 72 /kJ O C T 2 5 2021 TRANE' Submittal CITY OF TIGARD BUILDING DIVISION Prepared For: Date: October 05, 2021 All Bidders Job Name: McD 18011 Tigard, OR Trane U.S. Inc. is pleased to provide the following submittal for your review and approval. Product Summary Qty Product 2 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop (Y4C) 1 Adapter curbs Lauri Frankowski The attached information describes the equipment we propose to Trane U.S. Inc. furnish for this project,and is submitted for your approval. 7100 South Madison Willowbrook, IL 60527 Product performance and submittal data is valid fora period of 6 months from the date of submittal generation.If six months or Office Phone: (630) 734-3200 more has elapsed between submittal generation and equipment release, the product performance and submittal data will need to be verified.It is the customer's responsibility to obtain such verification. Table of Contents Product Summary 1 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop (Y4C) (Item Al) 3 Tag Data 3 Product Data 3 Performance Data 3 Mechanical Specifications 4 • Dimensional Drawings 8 Weight, Clearance & Rigging 12 Accessory 14 Adapter curbs (Item B1) 16 Tag Data 16 Product Data 16 McD 18011 Tigard,OR October 05,2021 Tag Data -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop (Y4C) (Qty: 2) Item Tag(s) Qty Description Model Number Al Y4C-1, 2 3-10 Ton R-410A PKGD Unitary YHC092F3RHA""P0C1A1B000A00000010 Y4C-1-1 Gas/Electri 00000000 Product Data - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop (Y4C) Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 DX cooling, gas heat High efficiency Convertible configuration 7.5 Ton Dual compressor 208-230/60/3 Microprocessor controls High gas heat Low Leak Econ-comp enthalpy 0-100%/BR 3p Hinged panels/2 in pleated filters MERV 8 Standard condenser coil w/hail guard Through the base electrical Non-fused disconnect Powered convenience outlet Return air smoke detector Human Interface Year 6-10 heat exchanger warranty Performance Data -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop (Y4C) Tags Y4C-1, Y4C-1-1 Airflow Application Downflow Cooling Entering DB (F) 80.00, Cooling Entering WB (F) 67.00 Ambient Temp (F) 95.00 Heating EAT(F) 70.00 Run Acoustics Yes McD 18011 Tigard,OR October 05,2021 Mechanical Specifications -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8", foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Two-Inch Pleated Filters 2" pleated media filters shall be available on all models. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 7%-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8%ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 7%to 8%(high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined McD 18011 Tigard,OR October 05,2021 tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual-sloped, removable and reversible condensate drain pan with through-the- base condensate drain is standard. Tool-less Hail Guards Tool-less, hail protection quality coil guards are available for condenser coil protection. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions(Gas/Electric Only). Hinged Access Doors Sheet metal hinges are available on the Filter/Evaporator, Supply Fan/Heat, and the Compressor/Control Access Doors. • Powered or Unpowered Convenience Outlet This is a GFCI, 120v/15amp, 2 plug, convenience outlet, either powered or unpowered. When the convenience outlet is powered, a service receptacle disconnect will be available. The convenience outlet is powered from the line side of the disconnect or circuit breaker, and therefore will not be affected by the position of the disconnect or circuit breaker. This option can only be ordered when the Through the Base Electrical with either the Disconnect Switch or Circuit Breaker option is ordered. Plenum Fan The following unit shall be equipped with a direct drive plenum fan design (all 10 tons and 7.5-8.5 ton high efficiency units). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. McD 18011 Tigard,OR October 05,2021 • Through the Base Electrical Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid-tight conduit and an external field-installed disconnect switch. Through the Base Electrical with Disconnect Switch This 3-pole, molded case, disconnect switch with provisions for through the base electrical connections are available. The disconnect switch will be installed in the unit in a water tight enclosure with access through a swinging door. Wiring will be provided from the switch to the unit high voltage terminal block. The switch will be UL/CSA agency recognized. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit overcurrent protection. Supply and/or Return Air Smoke Detector Smoke detector shall be factory installed photoelectric smoke detector mounted in the return air section (with or without the economizer or motorized damper option), AND/OR in the supply air fan compartment. The detector will be wired for continuous power whenever the unit is energized. Upon detection of smoke, the detector will shut down all unit operations. Local codes may dictate the location of detectors. Note: Due to the shipping position of the economizer or motorized damper, the return air smoke detector will not be completely factory installed. The wiring harness for the detector will be routed and tied off in the fan compartment for shipping. The smoke detector and barometric damper hood will also be installed in a shipping position in the fan compartment. Supply, Return, and Plenum Air Smoke Detector With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. In order for the supply air smoke detector or return air smoke detector to properly sense smoke in the supply air stream or the return air stream, the air velocity entering the smoke detector unit must be between 500-4000 feet per minute. Equipment covered in this manual will develop an airflow velocity that falls within these limits over the entire airflow range specified in the evaporator fan performance table. Supply and/or Return Smoke Detectors may not be used with the Plenum Smoke Detector. ***ATTENTION*** For installation in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com. Sequence of Operation (if applied in a SINGLE-ZONE CONSTANT-VOLUME SYSTEM or a CHANGEOVER BYPASS SYSTEM) B. SINGLE-ZONE CONSTANT-VOLUME SYSTEM 1. OCCUPIED HEAT/COOL: The RTU shall operate the supply fan continuously and modulate (or cycle) compressors, modulate (or stage) heat, and/or enable airside economizing to maintain zone temperature at setpoint. The OA damper shall open to bring in the required amount of ventilation. 2. MORNING WARM-UP/PRE-COOL: The RTU shall operate the supply fan and modulate (or cycle)compressors or modulate (or stage) heat to raise/lower zone temperature to its occupied setpoint. The OA damper shall remain closed, unless economizing. D. CHANGEOVER BYPASS SYSTEM 1. OCCUPIED HEAT/COOL: Each VAV terminal shall use pressure-independent control, with airflow measurement, to vary primary airflow to maintain zone temperature at its occupied setpoint. The RTU shall modulate the bypass damper to maintain duct static pressure at setpoint and modulate (or cycle) compressors, modulate (or stage) heat, and/or enable airside economizing based on current zone cooling/heating demands. The OA damper shall open to bring in the required amount of ventilation. II 2. MORNING WARM-UP/PRE-COOL: Each VAV terminal unit shall vary primary airflow to raise/lower zone temperature to its occupied setpoint. The RTU shall modulate the bypass damper to maintain duct static pressure at setpoint and modulate (or cycle) compressors or McD 18011 Tigard,OR October 05,2021 modulate(or stage) heat based on current zone cooling/heating demands. The OA damper shall remain closed, unless economizing. 3. COOLING/HEATING CHANGEOVER LOGIC: The System Controller shall determine the overall system cooling/heating mode based on "voting" from each zone. When the majority of zones require cooling, the RTU shall operate in cooling mode and any zone that requires heating shall reduce primary airflow to minimum. When the majority of zones require heating, the RTU shall operate in heating mode and any zone that requires cooling shall reduce primary airflow to minimum. tygl 7 1 McD 18011 Tigard,OR October 05,2021 Dimensional Drawings -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 ram'\, 7-TOP PANEL EVAPORATOR e~\���\ \\. SECTION• ACCESS PANEL �� �\ CONDENSER FAN CONDENSATE DRAIN(ALT) �\. vA. , • 3'4"-14 NPT DIA.HOLE \, ////j.. 1� ' \ •: 1 "-CONDENSER COIL 41.4 \`\ 27 518" UNIT CONTROL WIRE 7,8"DIA.HOLE �\ SERVICE GAUGE PORT ACCESS 1 3%8"DIA.HOLE 47 718" NIT POWER WIRE 1i2"NPT GAS CONNECTION (80MBH&120116H) / 314"NPT GAS CONNECTION (150:18H.240MBH&25OMBH) -/ CONTROL AND COMPRESSOR ACCESS PANEL PACKAGED GAS!ELECTRICAL THROUGH THE ISOMETRIC VIEW BASE CONDENSATE 4 1:8" 27 5/8"--.- EINIMINIIHMMINMal NOTES1.THRU-THE-BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS2.VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATIONe r---[---1 . 01" % 321B"RETURN I - 17 112" 9 718" - 17 1 r2" - �--3 5'8" PLAN VIEW UNIT DIMENSION DRAWING 1 - 46 7/8" RETURN HORIZONTAL 32 1/4" AIR FLOW 23 7/8" SUPPLY " I 24 1/2" ', • 9 5/8" 55/8II' 4 3/4" tr �IL���� II- 19 114" 4 9 318" - 16 314" 3 7/8" 4 1i4" - " CONDENSATE M 5 5.43" 88 5/8" 7 5/8" - PACKAGED GAS I ELECTRICAL 53 1/4" DIMENSION DRAWING i McD 18011 Tigard,OR October 05,2021 Dimensional Drawings -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 l'itikr-1 A\ K1/4. ,.,_-,,..,.--..--....... .0.1.r: et4 at . � I RETURN 314"-14 DIA HOLE CONDENSATE DRAIN tt t 27 5,8" 4 3f4" ISOMETRIC-PACKAGED COOLING McD 18011 Tigard,OR October 05,2021 Dimensional Drawings -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 ," --,---- '''TNst, , ,,,,,,,,,) fitiMA) � � ,___1 PANEL ON ACCESS SIDE � \.L_} CONDENSER COIL SIDE CONDENSER COIL SIDE t------) __ ——' THROUGH THE BASE ELECTRICAL /" 3 / (SEE NOTE 1 AND 2) 2 t4 Co THROUGHTHE BASE !4" J 3 3 CONDENSATE 5 7/8" - 5 517 NOTES `✓ 1.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD. PANEL VERIFY OPTION IN PRODUCT DATA IN THIS DOCUMENT. ACCESS SIDE 2.VERIFY WEIGHT,CONNECTION,OPTION CONFIGURATION AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION THRU THE BASE ELECTRICAL PLAN t ISO VIEW DRAWING McD 18011 Tigard,OR October 05,2021 Dimensional Drawings -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 ELECTRICAL/GENERAL DATA GENERAL a'4�xel HEATING PERFORMANCE Model. YHC092F Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 187-253 MCA: NIA Unit Primary Voltage: 208 Heating Model: High lint Secondary Voltage 230 MFS: N/A Heating Input(BTU): 200,000/140,000 Use Hertz. 60 FACB: N/A Heating Output(BTU)' 160,000 112,000 Unit Phase: 3 No.Burners: 4 No.Stages 2 EER 12.6 Standard Motor Field Installed Oversized Motor Gas Inlet Pressure MCA: -42.0 MCA NIA Natural Gas ,tin/Max): 41/2"t14" MFS: 50.0 MFS: N/A LP(Mil/Max) 11"/14" MCB: 50.0 MCB: N/A Gas Pipe Connection Size: 3%4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number. 1 Number: Number: NIA Horsepower 2.75 Horsepower Horsepower N/A Motor Speed(RPM): — Motor Speed(RPM): Motor Speed(RPM): WA Phase 3 Phase Phase NIA Full Load Amps: 7.3 Full Load Amps: Full Load Amps: NIA Locked RotorAmps: _- Locked Rotor Amps: Locked Rotor Amps' N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 2 Number 1 Horsepower. 4.1/2.4 Horsepower. 0.75 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 15.910.0 Phase: 1 " Locked Rotor Amps: — Full Load Amps: 4.0 POWER EXHAUST ACCESSORY (3,7) FILTERS REFRIGERANT (2) (Field Instated Power Exhaust) Type R-410 Phase: N;A Type. Throwaway Horsepower: N/A Furnished' Yes Factory Charge Motor Speed(RPM): N/A Number 4 Cccut 01 5.5 b Full Load Amps' N/A Recommended 20"x25"x2" Circuit#2 4.2 t) Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.Fora mom precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. 7.Installation of this power exhaust kit wit effect unit level MCA and could affect MOP sizing having a direct impact on existing field wiring and unit protection devices.The change in MCAAd OP is the sole responsiliity of the field installing party.Trane will not issue new nameplates as a result of this power exhaust accessory instatation.FLA of the power exhaust kit option must be added to the MCA of the unit for budding supply conductor sizing determination.. McD 18011 Tigard,OR October 05,2021 Weight, Clearance & Rigging -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 91.01b MOTORIZED OUTSIDE AIR DAMPER `-t , MANUAL OUTSIDE AIR DAMPER �(^' ' ��"/`"u, BAROMETRIC RELIEF OVERSIZED MOTOR x1` \ BELT DRIVE MOTOR ///!lli7l •,,�111 POWER EXHAUST VrII�1 • j THROUGHT THE BASE ELECTRICAUGAS(FLOPS) 13.0Ib i - ,� �jl/f UNIT MOUNTED CIRCUIT BREAKER(HOPS) �� UNIT MOUNTED DISCONNECT(FLOPS) 5.0lb POWERED CONVENIENCE OUTLET(FLOPS) 38.0 lb � ' C/ HINGED DOORS(FLOPS) 12_0lb (� HAIL GUARD 20.0 lb �^/ SMOKE DETECTOR.SUPPLY I RETURN 7.0 lb PACKAGED GAS/ELECTRICAL NO VAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET t._J 340.0lb © 249.0Ib (E)LENGHT (F)WIDTH • 1124.0 lb 1026.01b © I 233.0 lb 0 204.0 lb 41" 23" NOTE: 1 Ah weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3 The actual weight are listed on the unit nameplate. 4. Refer to unt nameplate and installation guide for weights before scheduling transportation and installation of unit. \\\\ 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated of+r-f 0°.o of the nameplate weight. Verify weight,connection,and all dimension with installer documents before intonation. 7 Corner weights are given for information only. 8. Net'Shipping weight of optional accessories should be added to unt weight when ordering factory or field .40,iuoieopN'k."•s,.. installed accessories. a. (,_vr: U�/1 5 --,,,,,,,,..s. 4,-,A, .,:,,k,,,.,4,, ,„ ., tli ...,,,..4:.,, E � A•'�' „...t14 F PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY McD 18011 Tigard,OR October 05,2021 ' Weight, Clearance & Rigging -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 36" CLEARANCE 48" SUPPLY RETURN DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE t. ROOF OPENING I i UNIT OUTLINE 46" 53 1/4" I I ILL 46" 88518" PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING McD 18011 Tigard,OR October 05,2021 Accessory -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 ) i 1 1 ----"------' 1 1 ‘‘',<,,,, / / l / / \ \ i / r \ / v- -\-----21 ems• )4 5i8 SWING DIAMETER-HINGED DOOR(S)OPTION ACCESSORY - McD 18011 Tigard,OR October 05,2021 Accessory -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 2 Tag(s): Y4C-1, Y4C-1-1 \ 1111 c I /4 I `ECONOMIZER HOOD 0000 0 0 IN BAROMETRIC RELIEF HOOD 1 ECONOMIZER HOOD T' -S-4. ._._.---- ----]- 36 V2" ` If 00 1 1 (----1 00 11 118" - 27 7/8" - LOW LEAK ECONOMIZER HOOD ACCESSORY �1WW>f/t/if/4llYlHIRfNXSNLtFtfllfiHYTJJfsfftiSlFNr�e�. McD 18011 Tigard,OR October 05,2021 Tag Data -Adapter curbs (Qty: 1) Item Tag(s) Qty B1 MAT-1-1 1 Product Data -Adapter curbs Item: B1 Qty: 1 Tag(s): MAT-1-1