Loading...
Report t o coo cg$ tk P vieC2C22-oo c e s GP #1 MODEL: 48TCDD12A2A5-0A0G0 RECEIVED Product Data MAR 03 2022 Carrier WeatherMakero CITY OFTIGARD BUILDING DIVISION Turn to the experts Single Packaged Rooftop Gas Heat/Electric Cooling 6 to 15 Nominal Tons WeatherMaker p4 I W ?.,. T q gt I xz41:4t: t i lr 48TC 07,08,09, 12, 14, 16 with Puron®(R-410A)Refrigerant ©2020 Carrier Form 48TC-7-16-03PD Rev.A GP #1 MODEL: 48TCDD12A2A5-0A0G0 Model number nomenclature (arri r MODEL NUMBER NOMENCLATURE Position: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Example: 4 8 T C D D 0 8 A 1 A 5 - O A O G 0 Unit Heat Type Packaging Compliance 48-Gas Heat Packaged Rooftop 0= Standard 1 = LTL Model Series-WeatherMakef TC-Standard Efficiency Electrical Options Non USA Models—No SAW Included Heat Options A=None D= Low Heat C=Non-Fused Disconnect E= Medium Heat D=Thru-The-Base Connections F= High Heat F=Non-Fused Disconnect and S= Low Heat w/Stainless Steel Exchanger Thru-The-Base Connections Standard USA Models—SAV included R= Medium Heat w/Stainless Steel Exchanger G=2-Speed Indoor Fan(VFD)Controller T = High Heat w/Stainless Steel Exchanger J =2-Speed Fan Controller(VFD)and Non-Fused Disconnect Rettig.Systems Options K=2-Speed Fan Controller(VFD)and A= One Stage Cooling Models(Size 07 Only) Thn3-The-Base Connections B= One Stage Cooling Models with M=2-Speed Fan Controller(VFD) Humidi-MiZer5(Size 07 Only) with Non-Fused Disconnect and D= Two Stage Cooling Models 08-16 Thru-The-Base Connections E= Two Stage Cooling Models 08-16 with Al/Cu condenser Coils and with Humidi-MiZer Service Options M= Single Circuit,Two Stage Cooling Models 0= None (Sizes 08,09,12 Only) 1 = Unpowered Convenience Outlet 2= Powered Convenience Outlet CooNng Tons 3= Hinged Panels 07=6 tons 12=10 tons 4= Hinged Panels and 08=7.5 tons 14=12.5 tons Unpowered Convenience Outlet 09=8.5 tons 16=15 tons 5= Hinged Panels and Powered Convenience Outlet Sensor Options A= None Intake/Exhaust Options B= RA Smoke Detector A= None C= SA Smoke Detector B= Temperature Economizer w/Barometric Relief D= RA+SA Smoke Detector F= Enthalpy Economizer w/Barometric Relief E= CO, K= 2-Position Damper F= RA Smoke Detector and CO, U= Temperature Ultra Low Leak Economizer G= SA Smoke Detector and CO, w/Barometric Relief H= RA+SA Smoke Detector and CO2 W= Enthalpy Ultra Low Leak Economizer J = Condensate Overflow Switch(electro-mechanical controls only) w/Barometric Relief K= Condensate Overflow Switch and RA Smoke Detectors L= Condensate Overflow Switch and RA and SA Smoke Detectors Base Unit Controls 0= Electro-mechanical Controls can be used with W7212 Indoor Fan Options EconoMi$er5 IV(Non-Fault Detection and Diagnostic) 1 = Belt Drive,Standard Static Option 1 = PremierLinkT"Controller 2= Belt Drive,Medium Static Option 2= RTU Open Multi-Protocol Controller 3= Belt Drive,High Static Option' 6= Electro-mechanical w/2-Speed Fan and W7220 C= High Static Option with High Efficiency Motor(Size 16 Only) Economizer Controller Controls.Can be used with W7220 EconoMi$er X(w/Fault Detection and Diagnostic) Coll Options-RTPF(Outdoor-Indoor-Hall Guard) A= Al/Cu-Al/Cu Design Revision B= Precoat Al/Cu-Al/Cu - = Factory Design Revision C= E-coat Al/Cu-Al/Cu D= E-coat Al/Cu-E-coat Al/Cu Voltage E= Cu/Cu-Al/Cu 1 = 575/3/60 F= Cu/Cu-Cu/Cu 5= 208-230/3 M= Al/Cu-Al/Cu-Louvered Hall Guard 6=460/3/60 N= Precoat Al/Cu-Al/Cu-Louvered Hail Guard P= E-coat Al/Cu-Al/Cu-Louvered Hail Guard Q= E-coat Al/Cu-E-coat Al/Cu-Louvered Hail Guard R= Cu/Cu-Al/Cu-Louvered Hail Guard 'Not available for 48TC*M08 units. S= Cu/Cu-Cu/Cu-Louvered Hail Guard NOTE:Not all possible options are displayed,see the current Coil Options-Novation®(Outdoor-Indoor-Hail Guard) 48TC 6 to 15 Ton Price Pages for more details. G=AI/AI-Al/Cu H= AI/AI-Cu/Cu J = Al/Al-E-coat AVCu K= E-coat AVAI-Al/Cu L= E-coat AI/AI-E-coatAl/Cu T= AI/AI-Al/Cu-Louvered Hail Guard U= Al/AI-Cu/Cu-Louvered Hail Guard V= AVAI-E-coat AVCu-Louvered Hail Guard W= E-coat AVAI-AVCu-Louvered Hail Guard X= E-coat AVAI-E-coat Al/Cu-Louvered Hail Guard rail" .. CERTIFIED- .,.,w.anriuiracxarr.or° ASHRAE 4 - Unitary Large AC c s ususAMA Standard 3a01360 ereC 13 COMPLIANT Intertek puron 3 GP #1 MODEL: 48TCDD12A2A5-0A0G0 AHRI capacity ratings (Carrie AHRI COOLING RATINGS NOM. NET COOLING TOTAL IEER WITH IEER WITH 48TC COOLING REFRIGERANT SINGLE SPEED 2-SPEED CAPACITY CAPACITY POWER EER UNIT STAGES CIRCUITS (TONS) (MBH) (KW) MOTOR FAN INDOOR FAN MOTOR MOTOR A07 1 1 6.0 70.0 6.4 11.00 11.2 12.7 008 2 2 7.5 83.0 7.5 11.00 11.7 12.8 D09 2 2 8.5 99.0 9.0 11.00 11.7 12.8 e.e.....÷► D12 2 2 10.4 114.0 10.3 11.00 11.8 12.8 D14 2 2 12.5 140.0 12.9 10.80 11.0 12.2 D16 2 2 15.0 174.0 16.1 10.80 11.5 12.4 M08* 2 1 7.5 88.0 8.0 11.00 12.7 N/A M09 2 1 8.5 97.0 8.8 11.00 12.7 N/A M12 2 1 10.0 117.0 10.6 11.00 12.7 N/A LEGEND NOTES: 1. Rated and certified under AHRI Standard 340/360,as appropriate. AHRI - Air-Conditioning, Heating and Refrigeration Institute Test 2. Ratings are based on: Standard Cooling Standard:80°F(27°C)db,67°F(19`C)wb indoor. ASHRAE-American Society of Heating,Refrigerating and Air-Condi- IEER Standard:A measure that expresses cooling part load EER tioning Engineers efficiency for commercial unitary air conditioning and heat pump EER -Energy Efficiency Ratio equipment on the basis of weighted operation at various load IEER -Integrated Energy Efficiency Ratio capacities. IECC1 -International Energy Conservation Code 3. The 48TC*D rooftops meets the DOE-2018 (Department of N/A -Not Applicable Energy),ASHRAE 90.1-2016 and IECC1-2015 minimum efficiency requirements when equipped with the SAVTM (staged air volume) 'High static fan is not available on M08 units. option. 4. The 48TC'M rooftops meet the DOE-2018 minimum efficiency Gus requirement without the SAV option. U c ti.�i CERTIFIED,.0 L us nr www,ahridirectory.org Intertek Unitary Large AC AHRI Standard 340/360 CeNhcfl n aopan nnly when the cemykte syetem N listed meth ANNI. 1. IECC is a registered trademark of International Code Council,Inc 4 „ie44444tmk....N 1.4.44NN41.4.4 A4t1/iRN6FlNNRdb 4" `s ' ..... '- •, • ,. GP #1 MODEL: 48TCDD12A2A5-0AOG0 C Carrier , HEATING RATING TABLE -NATURAL GAS AND PROPANE 48TC AUSS HEAT EXCHANGER TEMP RISE THERMAL EFFICIENCY UNITS GAS HEAT INPUT/OUTPUT INPUT/OUTPUT (DEG F) (%) STAGE 1 (MBH) STAGE 2(MBH) LOW - 72/59 15- 55 82% 07 MED - 115/93 25- 65 81% HIGH 120/96 150/120 35- 80 80% LOW - 125/103 20- 50 82% 08 MED 120/98 180/148 35- 65 82% HIGH 180/147 224/184 45- 75 82% LOW - 125/103 20- 50 82% 09 MED 120/98 180/148 30- 65 82% HIGH 180/147 224/184 40- 75 82% LOW 120/98 180/148 25- 65 82% -,,."., 12 MED 180/147 224/184 30- 65 82% HIGH 200/160 250/205 35- 70 80% LOW 120/98 180/148 20- 65 82% 14 MED 180/147 224/184 25- 65 82% HIGH 200/160 250/205 25- 70 80% LOW 144/118 180/146 15- 55 81% 16 MED 192/156 240/195 20- 60 81% HIGH 280/224 350/280 35- 65 80% NOTES: 1. Heat ratings are for natural gas heat exchangers operated at or below 2000 ft (610 m). For information on propane or altitudes above 2000 ft (610 m), see the Application Data section of this book.Accessory Propane/High Altitude kits are also available. 2. The input rating for altitudes above 2000 ft(610 m)must be derated by 4%for each 1000 ft(305 m)above sea level. SOUND PERFORMANCE 48TC COOLING OUTDOOR SOUND(dB)AT 60 Hz UNIT STAGES A-Weighted 63 125 250 500 1000 2000 4000 8000 A07 1 78 88.8 81.8 76.9 74.4 73.3 69.8 66.3 62.7 M08 2 82 90.1 82.6 81.0 79.4 77.0 73.0 70.4 66.7 D08 2 82 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 M09 2 83 91.2 86.4 81.9 81.0 78.3 73.9 71.4 67.3 009 2 82 88.6 85.0 81.6 79.5 77.4 74.1 71.0 66.3 M12 2 82 88.6 85.0 81.6 79.5 77.4 74.1 71.0 66.3 D12 2 82 89.0 83.1 80.5 78.5 75.5 71.6 69.6 69.3 D14 2 87 87.0 85.2 84.6 84.9 82.2 78.4 75.3 72.9 D16 2 87 87.0 85.2 84.6 84.9 82.2 78.4 75.3 72.9 LEGEND pressure depends on specific environmental factors which nor- dB-Decibel mally do not match individual applications. Sound power values are independent of the environment and therefore more accurate. NOTES: 3. A-weighted sound ratings filter out very high and very low fre- t. Outdoor sound data is measured in accordance with AHRI fre- quencies,to better approximate the response of"average" human ear, A-weighted measurements for Carrier units are taken in standard 270. 2. Measurements are expressed in terms of sound power. Do not accordance with AHRI standard 270. compare these values to sound pressure values because sound 5 N v ND 3 CD M NOTES: UNITED P.0.POE KM 1H13 IO0wR.I IS INS Pwrdl•a 1K.lt.COMOIN ION (410 UNIT OUTDOOR 3 A N TEC NNOLOG IFS 31.K.5[.II AM Is allrt.t9 W0.iK latt33 CdRl lld 1xr11K 3MOOS MU1rtaall/YIYS YINI I[HdMKIOI SM 1. DIMENSIONS ARE IN INCHES.DIMENSIONS COIL TYPE Ilifr Cdnn3.IIL Oi Nt HiCla[P d dd ntxdl t 41,. IN 1 1 ARE IN MILLIMETERS. /t Ill 33 3!1 15 718 CARRIER lull [drd3nd3 Rlnn<d3d1. Kt[nA.[[a[dnK3. 2- CENTER OF GRAVIT} 187E-MOB RTPF I10181 18371 11031 0 IBTC NOB RTPF 19 3/8 36 1/8 27 7/B CONNECTION SIZES 112511 1925] 11081 A 1 3/8'1351 DIA FIELD POWER SUPPLY HOLE 3.y DIRECTION OF AIR FLOW - IBIC-Nlt RTPF/8 3/8 36 i/B 15 7/8 40-3/8 1/2531 19251 14031 11028] B 2 1/2.1641 DIA POWER SUPPLY NNOCNWT /1 1/4 33 3// 15 7/8 IBIC-DOB RTPF - -- - -- C 1 3/1.1571 DIA GAUGE ACCESS PLOD Irn 110181 1837] 11031 481C-D09 RTPF 49 3/8 36 3/8 15 7/8 I D 1/8.1221 DIA FIELD CONTROL MIRING HOLE 112531 19251 11031 �� 19 3/8 36 31B 15 T/8 ECONOMIZER MOW IO-3/1 f 3/1•-11 MPT CONDENSATE DRAIN 181f-D12 RTPF 112531 19251 11031 tOP/IONAl1 15271 F 7/2'11 NPT GAS CONNECTION 3/1•-14 NPT GAS CONNECTION 41 1/1 33 311 13 18it-DOB NCNx 110181 18511 1584.21 G 2'1511 DIA POWER SUPPLY KNOCK-NOT 0 49 3/8 36 311 I8TC-D12 MCX9 112531 19t5/B l271.11 '1� . - I. .- . - N tl THRU-THE-BASE CHART (FIELD 1NST) _ RTPF-RWND i/BE.PLATE FIN ICOPPER/ALUMI �6 MCMI-NOVATION IALUM/ALUMI ( THESE HOLES REWIRED FOR USE WITH SCOT KITS: IA • (((('+//��A 192518 1121]B CRBTMP RODAA01:GAS TNRU BASEPANri �� p•,L RETURN All 1 RETURN \'\\ ��/ ,. - AIR THREADED WIRE REO'D HOLE A CONDUIT SIZE USE SIZES IMAX.) FILTER ACCESS PANEL ` ■ 1/2' ACC. 7/8'122.21 Q (TOOT-LESS) / Y • 112' 21V i/8.122.2100 ���q ram- DRAIN CONDENSATE •OPf N7NG i 11/1'lDOt.0011 POWER 1 3//•111.11 1..6 CONDENSER COIL •-Illl/� \ t8-3// 1 / \\ !� IN BASE I7311 37-5/8 /03/8 Z• 1804]3/1'fPT GAS 1 3/I.11/.11 N INDOOR COIL SUPPLT 19551 110t71 UL 5\m//I Pl[N1 I - SEE TNRU AIR ACCESS PANEL I \\\\W. %///,BRM, SUPPLYP • 30021 PROVIDES 3/1'OFPIGS TNRU CUIB C ixf BASE • FLANGE d FITTING. HOLE SIZE: 1'150.81 �,�\�:vi 2 CHART 16 1 \U/ 14R95 u,n ii55I 1z»7 p _ THRU-THE-BASE CHART (FLOP) �7L1 FOR'TNRU•THE-BASEPAN'FACTORY OPTION, �(>() I IA --- L FITTINGS FOR ONLY N.T.E.2 ARE PROVIDED... 0 6 1/1 FOR BELOW LISTED MODELS. A FIELD rXi BACK 4\ • SUPPLIED 1/2'ADAPTER IS REWIRED �rri •�I 1 `FLUE 17591 8C7■EEN BASE PAN FITTING AND GAS VALVE: .ICn 175118 /TOOT Ig0D 18311 IB7CO.s•08.09 13501 TOP —25.1/2— 0 At 16471 It N 111611-11 1321/ 131118 r�.M • v n[crAlcu CONTROL eox DiscoxxfcT f s70 CONDENSER 111 LOCATION • ACCESS PANEL COMDEM6ATE FILTER 0 COIL DRAIN v 28 3/B'FT�r ® INDOOR BLOWER 1720] 3 OPTIONAL) ACCESS SUPPLY A7R y OPTIONALFACTOAF ^�^[fAC7ONY211/6 INSTAtI[D �i11111W1IFT OUTSIDEYJINSTALLED OISCONNFC7 CONVFNIEMCEI� 11091 - FAROL[ - I35318- t6AIRWil[1I I16591rn HANDLE( 6-SIB —_� i►R_I 03 8�= =i� 11681 toO i i u `1"1 : OOpL i/6/ _ - ^I 3.3/1 � 6.1/4 7 `J 1951 59_1/2 2-SIB' 8-3/8 11601 11171 5 3/1 /-318 175101 167] 31 12111 37-1/8 11161 4 11131 v TyP19101 19621 LEFT WIDTH 88-1/8 110051 BAROMETRIC 122381 SUPPLY Ak RETURN RELIEF FRONT AIR 4 RIGHT AIR FLOW D N MET MU WI.. 48TC 08-12 SINGLE ZONE ELECTRICAL 48TM500985 t. D 1 Or 2 10-01-10 11-24-08 COOLING WITH GAS HEAT F O �, 0 UNITED •0.105 Iwt IS NDCMNNI Is IIN MMI[RiN a Cwtl[N CpNNAIId fMNlfsid a 1M5[d INGS a law[if TECHNOLOGIES sSA0(00 n Aw I5 a1M1[NTO N0 1M 00HTss COON uAr 1N[ w[5 wI Cd511lKi[•A11 Nt ONw1[[ON STD.UNIT CORNER CORNER CORNER CORNER CARRIER 152n COI[N75 nu N01 ec Rlu[d[R d e5[D wlKd1 uNN1[N nfc[nAM[a cdn•cl. UNIT OUTDOOR WEIGHT••• WEIGHT(A) WEIGHT/111 WEIGHT/CI WEIGHT ID) C.G. cOwa.11d's w11m COMP. COIL TYPE LBS. KG. LBS. KG. LBS. KG. 18S. KG. LBS. KG. K 7 2 18TC-1108 RIPE 780 351 178 81 158 72 209 95 236 101 11 1/2 110541 33 7/8 18601 20 1/2 15211 •••STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING TOR OTHER OPTIONS AND ACCESSORIES.REFER TO THE PRODUCT DATA CATALOG. 48TC-9109 RIPE 920 418 212 96 183 83 2/3 110 282_ 128 10 7/8 110381 3/18611 23 1/8 15871 4811-1412 Ri PF 930 122 216 98 196 89 217 112 272 123.5 42 110671 33 1/8 18411 24 1/1 16161 18TC-008 RIPE 835 379 161 1/.5 170 77.2 255 115.8 246 111.7 11 7/8 111401 35 5/8 19051 19 3/8 11921 48TC-D09 RIPE 930 422 228 103.5 187 85 232 105.3 283 128.5 39 3/I 110101 32 7/8 18351 18 5/8 14731 4/4104. 181C•012 RIPE 940 127 231 104.9 189 85.8 234 106,2 286 129.8 39 3/I 110101 33 18381 18 1/2 14701 18TC•008 *CHI 805 365.5 160 72.6 153 69.5 240 109 260 118 13 110921 36 3/8 19211 20 3/8 1517.71 481C-012 MCHK 895 106.3 185 81 176 79.9 260 118 271 121.1 12 7/8 110891 35 1/2 19021 22 7/8 15811 RTPF -ROUND TUBE.PLATE FIN/COPPER/ALUM/ CORNER A CORNER B MCNK'*OVATION(ALUM/ALUNI IlElllll 4kimi ',.. L IEn. . I �I 0 ^ . �� C IJ �(/ii��/.0/ 4 __ I1 1 50.T11 KNN. i� —=s C_ I rr1 e - CORNER C CA C 3 TOP Z It o E v ' z rn • 0 h oo C) 2 • C . v © o v no-0 `� - `E�' : : oo t D FRONT N D MET • RAT[ SWIM 5 48TC 08-12 SINGLE ZONE ELECTRICAL [' 4 48TM500985 N 2 OF 10-01-10 11-24-08 COOLING WITH GAS HEAT F 0 > 0 0 Cii N / CA _