Loading...
Report (2) t1/4-1&CZ622 "Do / 70 OFFICE /` OO 72•Jo @rrielDRECE1\153 o22 GIIDING SIDN g30 SUBMITTAL Project Curtis Wright Date Thursday, September 2, 2021 �... . Table Of Contents Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM 48SS036 3 Unit Report 4 Certified Drawing 5 Performance Summary 6 Unit Feature Sheet 9 Spec Sheet 10 48SS060 11 Unit Report 12 Certified Drawing 13 Performance Summary 14 Unit Feature Sheet 17 Spec Sheet 18 48TJ06 19 Unit Report 20 Certified Drawing 21 Performance Summary 24 Unit Feature Sheet 27 Spec Sheet 28 48SS048 29 Unit Report 30 Certified Drawing 31 Performance Summary 32 Unit Feature Sheet 35 Spec Sheet 36 Packaged Rooftop Builder 1.61 Page 2 of 36 48SS036 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM 48SS036 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.61 Page 3 of 36 Unit Report For 48SS036 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Unit Parameters Dimensions (ft. in.)&Weight(lb.)*** Unit Model: 48VL-C360606 Unit Length: 4'0.1875" Unit Size: 36(3.0 Tons) Unit Width. 2'8.625" Volts-Phase-Hertz. 460-3-60 Unit Height 4'3.75" Heating Type' Gas *`* Weights and Dimensions are approximate.Weight does not include roof Duct Cfg. Vertical Supply/Vertical Return curbs,unit packaging,field installed accessories or factory 60,000 BtUh installed options. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate Standard Unit product data catalog. Total Operating Weight 349 lb Warranty Information 1 year warranty on parts 5 year warranty on compressor 5 year warranty on heat exchanger No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48VL-C360606 Rooftop Unit 10 Base Unit Packaged Rooftop Builder 1.61 Page 4 of 36 Certified Drawing for 48SS036 Project: Curtis Wright 12/16/2021. Prepared By: 02:47PM vN1T ELECTRICAL UNIT 6T. UNIT OUGHT I414. CENTER OF 4444ITt I6t44 CBARACTERISTICS LS E6 •4" 3 i 2 444LE-1412241040/444734 218/230-1-60 344 138.4 13-314 1111 22-11/16 521.4 15.5/16 361.0 15-1111t 31e.5 4e(L/-/R/C10104044{013/ 208/230-1-40 136 152.4 45-1/4 1142 22-13/16 5/4,4 75-Slit 304./ 15-13/16 001.E -+ 9-15I16 4f_27 1/16 '.+ 1-15/1t^-- 4641(-161C3110t0/040313/5/4/0 254/230-1-60,208/210-3-40,460-3-60 341 158.0 51-3/4 1315 22-13/16 5/9.4 ES-5/14 381.1 16-5/0 422.3 C252.41 1541.71 [252.41 3-t21t-44 [WE0 REEGNT WIG I67.31 all 7tlLTA6[ •1• '>• 'i' '4' 161311 1 gEs * 24 2M1231 45.4 22.0 14.8 1f.6 91.2 11.4 717.4 44.1 ' 70 21ef171 $0.1 22.1 47.1 31.}1/0.6 43.1 1+7.{ 1.5 36 24e/230/460 52.4 23 t 61.8 31.1 114 7 47 5 122.2 55 4 ,TE]A4L 4 Y 1 A A ETUAN i OPTIONAL /11 15-15136 1 I 4NENIlG AIR [414.87 01ENI01; • 41 II 7 O R 3-3/1} iBORHi CLEARNESS Tb C:403/S16LE NAIL NICHES(RNA OU10006 COIL ]r T•E E6t S1 TCA OF 3011 14[355.61 -� DUCT 510E OF LIMIT. ..... ... 2 154.81 '_ ---- SIDE OPOOSIIE DUCTS. ..... . .... .. 14 1155.61 - F . 46TTO0 OF UNIT I/2 112.21 �- - FLANNEL.. 36 1114.41 .+4,446- -� I. - 1-1Etit Al MG I®DFD 08AMI� • Tr LICHEE[44] C7 I 4ET.EEA'24(1S,POKER(*103 SIDE. .. .... 12 C1444.31 // \ UNIT A40 06GR004DE0 SURFACES.Pd1R E6T1i S[OE 36 1274.01 (AOOOR COIL- \--GuiMOA COIL ONIT DED SHRIKES. OR C00C4ETE 01LL5.MO OTIE4 TOP VIEW 6*036115 SOAFAC16.PO6ER E4TR•sleE 42[1064 41 R7im CLIN S=POI 0ONSO1 NO SWAM INCHES I441 EPAP COIL A:CCSS SIDE ... 36 1914.01 PC*EN E4TR`5I3E 42 C1944.e1 IESCEPT FOR NEC REOII4EMERT5I UNIT TOP .. ., 40 02'9 21 SIDE 02P051TE OOCTS. . 36 I9t1 01 DUCT IA4EL...._.... ... ... 12 1114.11. 44I4I4U4 DISTM CES:EF 46Ii IS PLACED LESS 7I146 12 I214,41 IRON BALL 41 2-Ill 41 1 S3STE4,TIEN S1STE4 PERF0R644CE 4474E COWRON15E0 E'93`] [N.T1 1 r C1143 61 �+-4.1/2 f1t4.31 I!I 9I4ERSI06S I4[I ARE I4 w limillo - T _ 1 / KCE65IMEL IIIIIIII"IIII I"""""""""'i �I' UNI / e 016.43 119.6Y: �II'IIII""II _-mt'uuuu""'i� 0• 1 1 4 Te i/e'[22.21 OIA fplE •A r C72e7 CO4T90L EBTA7 -- E 1 - tl 15.7/e riri [1072] 3-Sq \'{ .2• 11-13/1f 7S-S 16 17 it- -0= /� [l2.t]• t •! - •I 1. _.1\ _1 [3i�1R1 I ISO4.1] f34t.f]1b-3ttt I'II �_ r--10' Elm 7] C�=�, (I Illmimii R56.61 �`1i 3.1/4 if larr 12-15/16 ROOMS \-OLORE7 4-13/16-+ 3/t6 /AEL 66• - 444EL 1122.2] G.11 13T5.41 iF2'[ttil B,P T 3-1/16 32-514 0-1/+{ 2-I/11 GAS MAY [61.31 eTe.i ^ P171.01 ti I-Il/I 1250)e1 (040 31 [250•81 5/4•[p1A11 A•PLT 1[46.07 A 7/6•122 21 DEEP LEFT SEE VIEW FRONT VIEW RIGHT SIDE VIEW REAR VEIN 48VL500404 _ Packaged Rooftop Builder 1.61 Page 5 of 36 Performance Summary For 48SS036 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Part Number:48VL-C360606 ARI SEER- 14.00 Base Unit Dimensions Unit Length: 48.2 in Unit Width• 32.6 in Unit Height 51.8 in Total Operating Weight 349 lb Unit Unit Voltage-Phase-Hertz. 460-3-60 Air Discharge- Vertical Fan Drive Type• Direct Actual Airflow. 1207 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB• 80.0 F Evaporator Entering Air WB• 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB• 59.9 F Evaporator Leaving Air WB• 57.9 F Evaporator Leaving Air Enthalpy: 24.99 BTU/lb Net Cooling Capacity 35.02 MBH Net Sensible Capacity: 26.21 MBH Total Unit Power Input 3.05 kW Coil Bypass Factor 0.054 Heating Performance Heating Airflow: 1207 CFM Entering Air Temp:. 70.0 F Leaving Air Temp• 106.8 F Gas Heating Input Capacity: 60.0 MBH Gas Heating Output Capacity 48.0 MBH Temperature Rise- 36.8 F AFUE(%)• 80.0 Supply Fan External Static Pressure. 0.50 in wg Options/Accessories Static Pressure Wet Coil- 0.10 in wg Total Application Static(ESP + Unit Opts/Acc.)• 0.60 in wg Fan RPM: 1000 Fan Power 0.66 BHP Fan Motor Size, hp• 3/4 NOTE: Med-High Motor Speed, Vert Selection includes construction throwaway filter into the base fan curve.This filter is not MERV Rated. Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor RLA: 5.8 Compressor LRA• 38 Outdoor Fan FLA(ea): 0.53 Indoor Fan Motor FLA. 3.2 Power Supply MCA: 11 Power Supply MOCP(Fuse or HACR)• 15 Packaged Rooftop Builder 1.61 Page 6 of 36 Performance Summary For 48SS036 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating: 72.0 db Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 74.5 250 Hz NA NA 71.7 500 Hz NA NA 68.9 1000 Hz NA NA 68.0 2000 Hz NA NA 62.6 4000 Hz NA NA 57.9 8000 Hz NA NA 52.5 Advanced Acoustics - :.-- 0 a 1 S Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 0.0 74.5 71.7 68.9 68.0 62.6 57.9 52.5 77.8 Lw B - 58.4 63.1 65.7 68.0 63.8 58.9 51.4 72.1 LwA 26.2 C 0.0 42.1 39.3 36.5 35.6 30.2 25.5 20.1 45.4 Lp D - 26.0 30.7 33.3 35.6 31.4 26.5 19.0 39.7 LpA 26.2 Legend A Sound Power Levels at Units Acoustic Center, Lw B A-Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.61 Page 7 of 36 Performance Summary For 48SS036 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.61 Page 8 of 36 Unit Feature Sheet for 48SS036 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM There is no Certified Drawing available for this tag Packaged Rooftop Builder 1.61 Page 9 of 36 Spec Sheet for 48SS036 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Packaged Rooftop Builder 1.61 Page 10 of 36 48SS060 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM 48SS060 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.61 Page 11 of 36 Unit Report For 48SS060 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Unit Parameters Dimensions (ft. in.)&Weight(lb.)*** Unit Model: 48VL-C600906 Unit Length. 4'0.1875" Unit Size: 60(5 Tons) Unit Width: 3'8.125" Volts-Phase-Hertz: 460-3-60 Unit Height- 4'6.75" Heating Type:. Gas "" Weights and Dimensions are approximate.Weight does not include roof Duct Cfg:_ . Vertical Supply/Vertical Return curbs,unit packaging,field installed accessories or factory installed options. Approximate dimensions are provided primarily for 90,000 BtUh shipping purposes.For exact dimensions and weights,refer to appropriate Standard Unit product data catalog. Total Operating Weight: ..... 455 lb Warranty Information 1 year warranty on parts 5 year warranty on compressor 5 year warranty on heat exchanger No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48VL-C600906 Rooftop Unit 2 Base Unit Packaged Rooftop Builder 1.61 Page 12 of 36 Certified Drawing for 48SS060 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM 13-15/t5 r- -++ •3-15,1i +- UOIT ELECTRICAL Olt Or. III HEIGHT IR/OO CENTER Of C.AYIT1 IRJW tHARALTC1I57ICS LE 66 •A• S 1 2 [331.C] (951 01 10YLF-l.)C4216401010123/5/410 200/236-1-60.200/230-3-60.416-3-60 .13 101.0 44.344 1131 22-1)/16 $14.1 16 4S0.3 11.1/6 433.0 3-1,14-+ 13-1/16 16YL(-,O)C16/D401115/1301C3/S/620 2044230-'-60,106/130-3-60.1i0-3-40 436 191.0 52.344 1340 22.13114 5T1.a II 151,2 17.316 441.3 162 31 [311 51 1311(-18>04010/0/11511301(3/S7610 264/230-!-65.2041230-3-60.410-3-60 455 264.0 34-3/4 13/1 22-13416 5/9.4 II 131.2 17•S/0 441.1 2-t31ti-1 0 RETURN it. SUPPLI C11 11 y]T PCLTA6E COMO fE[64TS LIM .0. .1. •2• •3• ii 0-"'�"-"---- +i 12 2D4/t10r41/ WO26-1 II 6 17.3 !23.1 31.2 111.1165. OPTIMA. , OPTICOAL 44 144,2y,160 6i.i 21.1 47.1 65.1 !it. 39.1 '51.7 H.5 .ETGR. ...PLY 60 244/130/A60 61.7 1`1•r0 41.1 !36,S WI !51.3 12.2 15-••..' • ! Aili OPIt1.6// 0PE.1R0 ' 11i 4,1 r • tM ROAM 6LLMYm 10�41i MIL' [4C115 1YYI TUP or WIT 11 C95-41 MT SIDE OF U411 . ,.2 [30.II 10 tl 510E 0610SITE S.KTS. .11[955 61 m 1. { 1 - - Ir 46TrON 6 017 ._ 1/2 112 11 - ii FLUE P61EL _ 30 Cilt.11 1 \ 1 i - -_ +} 16 1�7.A OlNI711R •• {! t_ __c......�___ 1 4.13116 42 1S$4] 1 �y . _ 4E3UEEY J3IT5.Wt06 E6TRT 4IM 34[(Y6/-07 �y1 1/T3.0] UBIT A60 U6640140E0 SU4FACES,PO4E0 EMI S10E..36 C414.01 � , ,• UOIT 00 MCI OR COOKIE DALLS A.0 0111. _ al`` 6O1060ED S49F.CES.Mel DOH SIDE... ...II 11066.41 CLAIM!M MM US 7E NOM 1.000.COILS --037000.COIL Er3P.C01L 4CCE15 SIDE.. ..31 I(3111 II TOP VIM POE.GTR*SIDE. : 2....111 tE10EP7 F07.EC IE06IEE9T5, .RIT RP ...40 11211.21 SIDE O'11051TE WKTS. - - 66 E9u01 DUCT MEL. , 11 12 CM al. 1111 14IRIW.O151450 S IF UIIIT IS PLACED LESS 7RA.12 C301.41 EN 11O'S/!6 4-1/2 7EA331044410E NATO!OO40U[(ED. 11090.61 C50.611 r [1193 61 E11/.11 OI4ERSI0AS 11..ORE 11* LICTRICAL IiiiHIIIIIIIIII 'IHIIHIIIHIIIIIII *Cass11/4'128.61 01A.I. IIOIOHIHIIIIIS i _ uIHIIIIHIIOIIH IllIDIlIUlUIl •IUUIIIHI000I 7/4•I22.2I DIA HDL� IIIIIIIIMEM••........- I .111111IIIII01111 'A• 1 pi"; C00TROA EODLE • I. • 71-710 I I/D3 T] OSCT I l OPE.LG 141u 121 J333J3 17-5/6 1111 _ [672.1J [11J.71 12•I/0 -0 = ` F• O• TO- 3a.4 1not� O cy ripe/)1 Ec ...._�J'i ORAL.OUTLET 601011E110' 104C6 8-4/16 3/4•[54.110,1,7 12-13/16 ..EL •0. P.EL .41.11 FP Eli II LP i,t4 1174•I22.21 DEEP I324.61 SAS EOM.J•1:!6 2-1214 (4.41 3-331 13-534 11.1/0 C93.'1 16-3114 E52.31 I41,31 1314,13 11122.41 11221.01 1-13n6 13-716 !7-v4 LEFT SCE VIEW FRONT VIEW 146.03 MI 1352.43REAR VIEW 1352 Al L.�I SIG •i.00 •600 I 48VL50040151GR - n L Packaged Rooftop Builder 1.61 Page 13 of 36 Performance Summary For 48SS060 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Part Number:48VL-C600906 ARI SEER: 14.00 Base Unit Dimensions Unit Length- 48.2 in Unit Width: 44.1 in Unit Height: 54.8 in Total Operating Weight 455 lb Unit Unit Voltage-Phase-Hertz: 460-3-60 Air Discharge' Vertical Fan Drive Type- Direct Actual Airflow: 2002 CFM Site Altitude* 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WE 67.0 F Entering Air Enthalpy:.. 31.44 BTU/lb Evaporator Leaving Air DB- 60.7 F Evaporator Leaving Air WB- 58.1 F Evaporator Leaving Air Enthalpy• 25.12 BTU/lb Net Cooling Capacity- 56.96 MBH Net Sensible Capacity: 41.70 MBH Total Unit Power Input 4.96 kW Coil Bypass Factor 0.230 Heating Performance Heating Airflow: 2002 CFM Entering Air Temp- 70.0 F Leaving Air Temp: 103.8 F Gas Heating Input Capacity: 90.0 MBH Gas Heating Output Capacity: 73.0 MBH Temperature Rise- 33.8 F AFUE(%)• 80.4 Supply Fan External Static Pressure: 0.50 in wg Options/Accessories Static Pressure Wet Coil- 0.10 in wg Total Application Static(ESP+ Unit Opts/Acc.). 0.60 in wg Fan RPM- 1040 Fan Power: 0.80 BHP Fan Motor Size, hp* 1 NOTE Med-High Motor Speed, Vert Selection includes construction throwaway filter into the base fan curve.This filter is not MERV Rated. Electrical Data Minimum Voltage- 414 Maximum Voltage- 506 Compressor RLA• 7.1 Compressor LRA- 52 Outdoor Fan FLA(ea): 0.53 Indoor Fan Motor FLA 4 Power Supply MCA- 13 4 Power Supply MOCP(Fuse or HACR). 20 Packaged Rooftop Builder 1.61 Page 14 of 36 s Performance Summary For 48SS060 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating: 72.0 db Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 81.3 250 Hz NA NA 72.6 500 Hz NA NA 68.2 1000 Hz NA NA 65.4 2000 Hz NA NA 62.9 4000 Hz NA NA 59.0 8000 Hz NA NA 54.4 Advanced Acoustics 0 Lik � CO , �� 4 S Advanced Accoustics Parameters 1. Unit height above ground* 30.0 ft 2. Horizontal distance from unit to receiver. 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 0.0 81.3 72.6 68.2 65.4 62.9 59.0 54.4 82.2 Lw B - 65.2 64.0 65.0 65.4 64.1 60.0 53.3 72.1 LwA 26.2 C 0.0 48.9 40.2 35.8 33.0 30.5 26.6 22.0 49.8 Lp D - 32.8 31.6 32.6 33.0 31.7 27.6 20.9 39.7 LpA 26.2 Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.61 Page 15 of 36 Performance Summary For 48SS060 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.61 Page 16 of 36 —^— ^R^^ Ifsrsa>iayswadslxawkiisalYrWadltatiHdiNti/fltiliM 4efSYfd tYUliW/1FiElf13DIWt IlWW a.fda Unit Feature Sheet for 48SS060 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM There is no Certified Drawing available for this tag Packaged Rooftop Builder 1.61 Page 17 of 36 Spec Sheet for 48SS060 Project: Curtis Wright 12/16/2021 • Prepared By: 02:47PM Packaged Rooftop Builder 1.61 Page 18 of 36 48TJ06 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM 48TJ06 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.61 Page 19 of 36 Unit Report For 48TJ06 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Unit Parameters Dimensions (ft. in.) &Weight(lb.)*** Unit Mode: 46FCDA06A2A6-OA0A0 Unit Length: 6'2.375" Unit Size: 06(5 Tons) Unit Width: 3' 10.625" Volts-Phase-Hertz: 460-3-60 Unit Height: 2' ".37 " Heating Type. Gas *** Total Operating Weight: 556 lb Duct Cfg. Vertical Supply/Vertical Return Low Heat ***Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are Standard One Stage Cooling Models provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size. 1/2 Condensate Drain Line Size. 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity: 2 Return Air Filter Size. 16 x 25 x 2 Selection includes construction throwaway filter into the base fan curve.This filter is not MERV Rated. Unit Configuration Direct Drive-EcoBlue-Medium Static Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48FCDA06A2A6-0A0A0 Rooftop Unit 2 Base Unit Direct Drive- EcoBlue-Medium Static None Packaged Rooftop Builder 1.61 Page 20 of 36 Certified Drawing for 48TJ06 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM `/ INIS DOCUMENT TA THE 1NOPERIY OF ETC CLIMATE.(CAIROL3 SIBMISSIDN DF 1.............TS NOTES: UNIT J K \� &SECURIT[OIIifI1ID ECLIUtREDBEPD�ISCLE[DISCUS FD�ITT� '"NDT[OF ETE PART PERFORMANCE D1 1. DIMENSIONS AIN IX INCHES. DIMENSIONS 33 3/8 18 5/8 dA•+N1'R+.MM/..WITHOUT WRITTEN CONSENT. ACCEPTANCE OF CONTRMT. IN[ 1 ARE IN MILLIMETERS. 48FCR.04 [Sail U721 2.fp CENTER OF GRAVITY 18FU405 3[83 47] 7]3/8 1/[3T7!8 CONNECTION SIZES 33-3/8 A 1 3/8' [351 DIA FIELD POWER SUPPLY HOLE 48FCR.06 33 3/8 14 7/8 18481 3. DIRECTION OF AIR FLOW [847] [377] B 2' [50]DIA POWER SUPPLY KNOCKOUT 46FC4R07 41 3/8 18 5/8 32-1/8 i C 1 3/4' [51]DIA GAUGE ACCESS PLUG 4. �� ALL VIEW DRAWN USING 3RD ANGLE [1051] [472] '� [817] ' ECONOMIZER HOOD ❑ [OPTIONAL/ D 7/8" [221 DIA FIELD CONTROL WIRING HOLE 16 • • [407] E 3/4"-14 APT CONDENSATE DRAIN 25-5/8 [652] E 1/2,14 APT GAS CONNECTION RETURN AIR G 2 1/2 ' [641 DIA POWER SUPPLY KNOCK-OUT 7.1 • /���\[ ♦ THRU-THE-OASE CHART ` ����� �1•C— (2111 THESE HOLES REQUIRED 01 FOR USE ., // /•,—> (2T77 RETURN CRBTMRO(1BA00, 009A00 •11ll#4.. L71���,�0111L AIR (I��j,��j�� IMPF/�, 1/I, THREADED WIRE flE0'D HOLE `1"\ / } CONDUIT SIZE USE SIZES ( \\\\\�\\`- ��/ W 1/2' 115V 7/8' [22.21 44-1/8 \�� % 1/ 3/4' 24V 7/8" [22.21 [1120.91 L �.; Y J E ALT. _ [748129-1/2 Y POWER 1-1/8" L28.6] CONDENSATE 11'3/4 Zr (D09A00) 1/2' FPT GAS 1-1/8" [28.6] • Z DRAIN OPENING [4511 SUPPLY FOR"THRU-THE-BASEPAN"FACTORY OPTION. IN BASEPAN AIR 26-5/8 FITTINGS FDA ONLY X. Y. d Z ARE PROVIDED t [6T51 SUPPLY 1 q.112 } AIR [008A007 PROVIDES 3/4'FPT THOU CURB [3697 12-1/2 11-1/2 - SEE TARS THE % _A FLANGE d FITTING. 4 [31�1 12931 BASE CHART ••�. . Y 1 .. 6 1 10-1/8- 2%23-3/4 3-1/4 _6-1/4 [256] [6037 [81] (158] 1 1Hoop [18,3 8 K 2%25 [635] [4661 2%11 14-5/8 118] TAP 1l 8] E STD. CONDENSATE 10-1/8 1 LECTRICAL DRAIN 12751 i' (251 DISCONNECT• _ • • j LOCATION "' `—� o�{ FILTER CONDENSER �l A,B,G OPTIONAL CONTROL BOX COIL ( FACTORY ACCESS PANEL '25-3/d 7-3/8 INSTALLED INDOOR BLOWER :16 3] I. [411] I DISCONNECT ACCESS PANEL RETUR OPTIONAL .��1 ' j t —SUPPLY AIR I AIR ;� __7 INSTALLED FACTORY l J • CONVENIENCE J .,'%[ I OUTLET ill F 'C. /—HANDLE 11-7I8III 1iF / [302] .� �[53914 .JOI 11 // p E �f] I,', O I,—J OUTSIDE 9-1/2 j 1491J AIR HANDLE 5-3/4 1111111 6 3/8 7 5-3/4 3-3/1 I.. 46-5/8 8-3/8 (146] 11617 [1711 [1461 1951 I11861 30-1/8 — [2141 [1661 26-1/8 [6821 LEFT I18897 [786] BAROMETRIC RELIEF FRONT SUPPLY FLOP f AIR RETURN RIGHT AIR ITC CLASSIFICATION SHEET DATE SUPERCEDES 48FC 04-07 SINGLE PACKAGE ELECTRICAL REV U.S. ECC N:NSfl 1 OF 3 09/07118 06/22/18 COOLING WITH GAS HEAT 48TC003093 A e Packaged Rooftop Builder 1.61 Page 21 of 36 i r Certified Drawing for 48TJ06 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM /���/ I"I DOCUMFNr IS THE PAOPERr,Or OTC CLIIIITE,CONTNOLS s M9s LOX W THESE DRAN'Nfid OR IA%ONENis {.(iT"164�Y� E4URITr AND[E 4CL[V[N[U UPOY iNE[NPREsd COXDSr1011 N puK'E OB STD. UNIT CORNEA CORNEA CORNER CORNER THAT TxE CONTENTS RILL WI BE DISCLOSED OR USED ACCEPTANCE ESE CONTRMT. UNIT WEIGHT• WEIGHT(A] WEIGHT l8) WEIGHT(CI WEIGHT ID) - C.G. HEIGHT O�N�•*•N••••r WITHOUT NUTTER CONSENT. LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. K Y 2 413FC••04 482 219 113 51 116 53 128 58 125 57 37 5/8[956] 24 9/16[6241 18 1/4[4641 48FC•405 543 246 138 63 133 60 133 60 138 63 36 1/2 1927] 23 3/8 [594] 18 [457] 48FC••06 556 252 142 64 136 62 136 62 142 64 36 1/2 19271 23 3/8 [594] 18 [457] 48F0•07 607 275 162 73 152 69 141 64 151 68 36 1914] 22 1/2 [572] 19 3/8[4921 •STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. t I BACK R12 1/2 WITH ECONOMIZER BACK 1318] \ 1— - , , WITHOUT i CORNER A ECONOMIZER ECONOMIZER HOOD CORNER B OPTIONAL DOOR \ (MIZIRNHO) SWING . -GI LLLLLI1 II' //���� \\\\\\\\�A RIGHT ---I Si CORNER D �� m•-.... / CORNER C LEFT u �' I X u-5/B TOP [1896] FRONT 1 I I �`T NOTES: ��( 1. FOR ALL MINIMUM CLEARANCES LOCAL CODES OR JURISDICTIONS MAY PREVAIL. III Z SERVK:E WRH CLEARANCE SERVICE WITN6 OPERATW4G i i t __ 1 SURFACE CONDUCTIVE BARRIER iOACOADl1CTIVE BARRER CLEARANCE I��7�1� ���7�i� FRONT 48 [1219mm] 36 [914mm] 18 [451mm1 LEFT 46 [1219mm] 42 [1067mm] 18 [457mm] FRONT BACK 48 [1219mm] 42 [1067mm1 18 [457mm] BACK W/H000 36 [914mm] 36 [914mm1 18 [457mm] RIGHT 36 1914mm] 36 [914mm] 18 [457mm] TOP 72 [1829mm] 72 [1829mm] 72 [1829mm] 1 ITC CLASSIFICATION SHEET DATE SUPERCEDES 48FC 04-07 SINGLE PACKAGE ELECTRICAL REV U.S. ECCN:NSR 2 OF 3 09/07/18 06/22/18 COOLING WITH GAS HEAT 48TC003093 A Packaged Rooftop Builder 1.61 Page 22 of 36 Certified Drawing for 48TJ06 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM \c iDI3 DOCUMENT IS THE PNOYENTY OE UTC CLIMATE,CONTROLS SUBMISSION OE 1HESE DRAWINGS OR DCCUNERTE l.fiiN/iGN 1 TI/[iY AMO IS DEL[VCREO UPON CLO CYPRESS DIDITION S NOT CONSTITUTE PART PEREORNANCE OR THAT THE CONTENTS MILL NOT BE DISCLOSED OR USED ACCEPTANCE OE CONTRACT. ..................WITHOUT WRITTEN CONSENT. 71-1/8 [1805.3] (INSIDE THE BASE RAIL A SKIRT) I1 e 1� ,cur .� ,:m. lV �' �\ ' , \ [104645] C)X (INSIDE THE BASE RAILS) � 1 Iv '2-1/4 41 2% [461 `. �� INSIDE BASERAIL DIMENSIONS 111' u6] 41100 211[4818 BOTTOM ,40 \TmEntttEnEm JW_+8 21 1-3/8 21 1 3-1/4 [361 [251 [821 -2X 3/4 3-7/8 f- [18] DETAIL C [991 TYP 4 PLCS FILTER ACCESS PANEL COMP. CONDENSER • • CONTROL BOB INDOOR BLOWER (TOOL-LESS) ACCESS COIL ACCESS PANEL ACCESS PANEL , PANEL • , O • INDOOR COILIII e • ACCESS PANEL • SEE DETAIL C® r I47 � y .' � }4OO I 11 I r r'l T� f I - i lI I I 1 � U `k I - 7 I �-�iI .�. I I JJJ b.�BACK LEFT [ .0 59-3/82 ] 0] ..--2-3/8 • [61.51787] TIP CURB FRONT WIDTH ITC CLASSIFICATION SHEET DATE SUPERCEDES 48FC 04-07 SINGLE PACKAGE ELECTRICAL REA U.S. ECCN.NSR 3 OF 3 09/07/18 06/22/18 COOLING WITH GAS HEAT 48T0003093 A Packaged Rooftop Builder 1.61 Page 23 of 36 Performance Summary For 48TJ06 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Part Number:48FCDA06A2A6-0A0A0 ARI SEER: 14.00 Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.6 in Unit Height: 33.4 in Operating Weight Base Unit Weight: 556 lb Total Operating Weight: 556 lb Unit Unit Voltage-Phase-Hertz: 460-3-60 Air Discharge: Vertical Fan Drive Type: Vane Axial Actual Airflow: 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB. 59.3 F Evaporator Leaving Air WB: 57.7 F Evaporator Leaving Air Enthalpy 24.85 BTU/Ib Gross Cooling Capacity 59.31 MBH Gross Sensible Capacity 44.73 MBH Compressor Power Input 4.14 kW Coil Bypass Factor' 0.163 Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 95.0 F Gas Heating Input Capacity: 67.0 MBH Gas Heating Output Capacity 54.0 MBH Temperature Rise: 25.0 F Thermal Efficiency(%): 81.0 Supply Fan External Static Pressure. 0.70 in wg Fan RPM: 2192 Fan Power: 1.13 BHP NOTE: Selected IFM RPM Range: 1478-2390 Selection includes construction throwaway filter into the base fan curve.This filter is not MERV Rated. Electrical Data Voltage Range: _ 414-506 Compressor#1 RLA: 7.8 Compressor#1 LRA: 52 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 1.9 Combustion Fan Motor FLA(ea)* 0.25 Power Supply MCA' 13 Power Supply MOCP(Fuse or HACR): 20 Disconnect Size FLA. 12 Packaged Rooftop Builder 1.61 Page 24 of 36 Performance Summary For 48TJ06 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Disconnect Size LRA: 57 Electrical Convenience Outlet: None Outdoor Fan [Qty/FLA(ea)]: 1 /0.8 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 93.6 90.3 85.6 125 Hz 85.1 80.9 84.7 250 Hz 79.1 72.8 80.5 500 Hz 75.3 67.8 76.0 1000 Hz 72.3 69.6 72.4 2000 Hz 69.7 61.0 68.0 4000 Hz 65.4 54.2 62.8 8000 Hz 61.0 48.2 59.3 A-Weighted 78.8 73.5 79.0 Advanced Acoustics 141 .44 Ai • Advanced Accoustics Parameters 1. Unit height above ground' 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver:...0.0 ft 6. Horizontal distance from unit to obstruction' 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 Lp D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.61 Page 25 of 36 Performance Summary For 48TJ06 . Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 24 �18 JT : \ CO 12 J____-M N cn - siBFP CS 1503F144 _ NN 9300FPN \ ,II� 06 _1100RPM ,•0: • 900RFTVto: \'. 03 �----- T .:. \. CO I I I I I I _ I 1 A CO 02 04 06 09 10 12 14 16 18 20 22 24 26 28 a) Airflow(CFM-thousands) RPM=2192 BHP=1.13 MaximumRPM=2836 MaximumBHP=5.00 SC-SystemCurveRP-RatedPoint Packaged Rooftop Builder 1.61 Page 26 of 36 Unit Feature Sheet for 48TJ06 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Carrier CI) WeatherMaker -48FC PACKAGED ROOFTOPGASHEATING/ELECTRICCOOLING UNrrS- 14 SEER 3,4,5 TONS,15IEER 6 Ton STANDARDFEATURESINCLUDE: 'rN 0 Puron(R-410A)HFCrefrigerant 0 MeetsorexceedsASHRAE90.1energyefficiencylevels 0 Saoloarpressorswihintemallinebreakandouerbadprotedion VIVI* Single-stagecodirgcapadty04-06mule6,TwoStageon07n WA, 0 SEER'sto14.0,IEERsto15.0 #'. 0 Acu efrigerantmeteringsystemon04-06models,TXVon07 sizenwckls f+ui ti 0 Exdusiw m pannaordanoewith ASHRAEStandard62,slopingdesign,sideorcenterdrain n" 0 Standardcodi ngoperationupto115°F(46°C)anddawrto40°F(4°C) downto25°F(-4°C)Othwinterstartkit. 0 Pre-paintedexteriorpanelsarxlprinrer-coatedinterbrpandstestedto 500hourssaltsprayproteclion 0 Fullyinsulatedcabinet 0 NEWDirectDtive-EcoBlueTechtulujyIndoorfansystemucPs ASH:RIE VaneAxialfandesigrandelectronicallyamrnuhatedmotor PurOn 0 NewUnitControlBoardwilhinWitivequidcfanspeedadjustrnent 0 ExdusivelGCsolid-statecontrolforon-boarddiagnosticswithLED COMPLIANT errorcodedesig nation bumercontrol logic 9 Irducedc}aftgasheatmndustiondesign 0 Redonda tgasvalveswitlwptotwost°yesotheating 0 Lowpressureandhighpressureswdchprotected. MAINTENANCEFEATURES: 0 P T.sparrelswilheasygriphandles VEA1HEFIM614313EFES Innovativeeasystarting,ro-strOcrewsonurrtaooesspands eleCUiC 0 Two-inchdispcuableretumairfiltersandTool-lessfilteraacessdoor 0 Newurtoontrdboardtofadlitatesimolesafetydreuittr ubleshooting cooinguislhetsciarew'redEndchargschnetharon ardsimpdedcontrdboxarrangement (R-410)refiigerantlheuritsarefaclaylestedinbdh I¢ili ym awing r utIbb.3f�e INSTALLATiONFEATURES: 6tn ,p 0 ThruthebottamPYczceb IA c 0 Singlepdntgasardelectricoonnections 0 FullperimeterbasPrailwithbuilt-inriggingadaptersandforksbts 0 Reldconvertiblefromverticaltohorizontalairfbw STANDARDWARRANTY: 0 10-yearh atexdianger-1`-yearstainlesssteeloption 0 AFP� 0 3-tearSystemVu 0 1-yearparts n. CERTIFIED_ 0 Manyoptionalupgradesalsoavailable Use of the Candled OPTIONS INCLUDE BUTARE NOTLIMrrEDTO: C (2) US M Mark inaka,ea a • IntelligentSy°tem Vucumrruricatingoontro6 manufacturer's p rwon vm iegroBarnFore� aron • RTUCpenMulti-Pritu iDDCContols • ScpplyandRetumAirSmokeDetectors,highstaticmotos or certification for ndordua' Louveredoordensercoil uards products,go to • 9 m renory.org • Dsoom ectavitehandoonverrenceoutletoptions • Staim>fessSteelheatexdtangeroption • Corrosbnresistantcoilcoating. • MERV-8RetumAirFilters • PatentedHumiti-MiZer '''adapVwedehumricifi,atiarsystem. • Hingedarrpsspanels • Integraledemrarnizersystem.LowardUltaLowL.eavemsions • PhaseMonitorRotection • CondensateOverlimPrntedion For aoomplete listofoptions and accessories refertothe Product Data Catalogforthisunit. Packaged Rooftop Builder 1.61 Page 27 of 36 Spec Sheet for 48TJ06 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Packaged Rooftop Builder 1.61 Page 28 of 36 48SS048 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM 48SS048 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.61 Page 29 of 36 Unit Report For 48SS048 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Unit Parameters Dimensions (ft. in.) &Weight(lb.) *** Unit Model: 48VL-C480906 Unit Length. 4'0.1875" Unit Size: 48(4 Tons) Unit Width: 3'8.125" Volts-Phase-Hertz: 460-3-60 Unit Height. 4'4.75" Heating Type' Gas *** Weights and Dimensions are approximate.Weight does not include roof Duct Cfg: Vertical Supply/Vertical Return curbs,unit packaging,field installed accessories or factory installed options. Approximate dimensions are provided primarily for 90,000 Btuh shipping purposes.For exact dimensions and weights,refer to appropriate Standard Unit product data catalog. Total Operating Weight:____ 438 lb Warranty Information 1 year warranty on parts 5 year warranty on compressor 5 year warranty on heat exchanger No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48VL-C480906 Rooftop Unit 1 Base Unit Packaged Rooftop Builder 1.61 Page 30 of 36 Certified Drawing for 48SS048 Project: Curtis Wright 12/16/202.1 Prepared By: 02:47PM 13-15f16 .}-151f6 WIT ELECTRICAL UNIT R. OBIT HEWINIHA CENTER Of 4RAYITI I91101 CHARACTERISTICS LB KG 'A' X 7 2 1354 03 [331 el 4171.1 J1761210801080113f5/610 206/230-!-60,201/230-3-10.160-3-60 413 IICO 44-314 1137 27.13711 319.4 t0 157.E 17-176 135.4 3-r:•6 016 iv 31 it (341 I4YL1-/17C/1/0107115/130113/51610 206J230-+-60.208/230-3-60,160-3-60 431 M4432-314 1 310 22.13/11 371.4 11 451,2 11-3J1 441.3 .31 NVL(-111C1040901l11f+301t 315/i 10 E06/230-1-60,201e231-3-60.110-3-10 655 I04.0 51-3/1 1311 22.1 3/11 319.1 t/ IS1.2 17-$26.117.7 2-C111 11 3/it1 4 RETURN i SUPPLY IN W]T PCLTAOL CO/ICR 1E[GIIT5 L/1G 1 S - -- = r ap�1 42 201,2301144 62.0 29.1 02.1 PiPi123./ $6.7 s11.t 63.6 1 OPTICaLL OPEIOIAL Ilk18 12301160 it? MI /1.4 33.1 131.4 59.E •31.3 615 A]gORN u#OLT 60 1011E 1pf1{0 11.1 3'.1 9'.0 41.7 13{.5 67.1 15f.3 7I.2 I5.75714[10,el 1 ;A'[NING O/E131G III • t II - >w 41 11 1��, w I�Maws TO 07R/Rd SOL [5CIES POI �1 10,OF WIT 14 C351.11 081000R COIL 3-31t8 MT SIDE OF ®ODCTS.. .14 C35R5.i1 [1,.01 I 10TT01 CF WIT ,f2 C12./I }f 11 FLOE PNBEL . .34 LIUA 11 'r• J.= �. RC IRA N11010s.. _ [ORES 101 lir ,4 ==ter--_ --�.i, 6-13111 0ETBEE6&NITS PO4E6 C17t1 SIDE 47 I10K 81 I1i3.0) OMIT AIO UIIGRODORED SOaiACES,PLS 4 E10RY SIDE.36 LfI1.01 D1IrAID9La101G' I(Ill525 011E1 SKAT�WE0 SURFKES,WI Wet SIDE. _.A2 0666.61 MOOD WM=Ka WA=PO Mal MIEI500W COILS . 0001 COIL free COIL 1[CE55 SIDE. li [f7iy01i TOP VIEW10ER EBTAr SIE. . 11[la6t 61 OEICEPT FOR KCEWIENEITS` UNIT TOP ....Al 1121121 SIDE OPPOSITE WS, 16 [114 61 DUCT PAIEL. . 17 Oat MP 3111IR11 O ISTNrEs'IF 4BI1 IS PLACED LE55 TIAN 12[181.al 1100 DAL SISTEP,11E4 SISTER 42-15/14 17 1-1f1 PERFORBR9CE 1AT1E C0MP101I5E3. 11010.61 ESa.el 11113.11 [114 3] DIBEISI015 IB II ARE 11 w L[CTIICAL IlIllOIllIllIll _ _ IIHUIIIIIIIIIII! ACCI-rid.[25.61 31A R SS PA.EL _ _ IIIIIIIIIIIIIIIII IIllOIl101101Ill! 1IUIIIIIIIIIII .........________. . 1lUlIllUIllIllIll 4.J// ill'[22COIIl01A E11T1Y IlIlIlIlIlIOlIHI IIIIIIIIIIIIIIIIIIII- I {E123.d1 1/-t211 [112 f] !t-T11 LOW II { ` 1, ®I =�` (1 ] 12-118 I ` B 1 403 21 OPE BIN OOPL IIIII 11311 I !tea♦MI •1 6.-6111 -0 AL I• •O• TO• • Ymmi 0 [1H.1 01411 OUTLET- {OIMICS �OLOIER 5•fil{ Re110.111,P.T 11-15J11 BAEL .1" PANEL (111,31 \---I 2'C11 11 B,P.1 1 UV[UM HP 1321.67 OAS EOM lni 3-11116 2-1/16-.- (1.111 3-3/3 i3-S78 4I-1/d [93.71 41-2e.6 [52.41 MA 37 11122./1 11224.01 [i4.17 1-1 3 /16--t- RIGHT SIDE VIEW 13-Y11 ,a-I,{ LEFT •E• �w �w In 01 1152.43 �� VIEW (352 u FRONT 48VL500405 - D Packaged Rooftop Builder 1.61 Page 31 of 36 Performance Summary For 48SS048 • Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Part Number:48VL-C480906 ARI SEER. 14.00 Base Unit Dimensions Unit Length: 48.2 in Unit Width:_____ _ 44.1 in Unit Height: 52.8 in Total Operating Weight: 438 lb Unit Unit Voltage-Phase-Hertz. 460-3-60 Air Discharge. Vertical Fan Drive Type. Direct Actual Airflow. 1688 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB- 67.0 F Entering Air Enthalpy:. 31.44 BTU/lb Evaporator Leaving Air DB. 60.6 F Evaporator Leaving Air WB. 58.4 F Evaporator Leaving Air Enthalpy- 25.32 BTU/lb Net Cooling Capacity. 46.47 MBH Net Sensible Capacity: 35.45 MBH Total Unit Power Input 4.04 kW Coil Bypass Factor- 0.056 Heating Performance Heating Airflow. 1688 CFM Entering Air Temp. 70.0 F Leaving Air Temp. 110.0 F Gas Heating Input Capacity. 90.0 MBH Gas Heating Output Capacity. 73.0 MBH Temperature Rise' 40.0 F AFUE(%): 80.4 Supply Fan External Static Pressure. 0.50 in wg Options/Accessories Static Pressure Wet Coil. 0.10 in wg Total Application Static(ESP+ Unit Opts/Acc.)- 0.60 in wg Fan RPM:_ _ 1075 Fan Power 0.50 BHP Fan Motor Size, hp. 1 NOTE. Medium Motor Speed, Vert Selection includes construction throwaway filter into the base fan curve.This filter is not MERV Rated. Electrical Data Minimum Voltage. 414 Maximum Voltage: 506 Compressor RLA- 6.2 Compressor LRA- 41 Outdoor Fan FLA(ea): 0.53 Indoor Fan Motor FLA. 4 Power Supply MCA: 12.3 Power Supply MOCP(Fuse or HACR). 15 Packaged Rooftop Builder 1.61 Page 32 of 36 ar Performance Summary For 48SS048 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating• 72.0 db Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 75.4 250 Hz NA NA 70.7 500 Hz NA NA 68.9 1000 Hz NA NA 67.4 2000 Hz NA NA 62.6 4000 Hz NA NA 59.9 8000 Hz NA NA 56.7 Advanced Acoustics 011 11 p • SIAN Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 0.0 75.4 70.7 68.9 67.4 62.6 59.9 56.7 78.0 Lw B - 59.3 62.1 65.7 67.4 63.8 60.9 55.6 72.0 LwA 26.2 C 0.0 43.0 38.3 36.5 35.0 30.2 27.5 24.3 45.6 Lp D - 26.9 29.7 33.3 35.0 31.4 28.5 23.2 39.6 LpA 26.2 Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.61 Page 33 of 36 Performance Summary For 48SS048 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.61 Page 34 of 36 Unit Feature Sheet for 48SS048 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM There is no Certified Drawing available for this tag Packaged Rooftop Builder 1.61 Page 35 of 36 Spec Sheet for 48SS048 Project: Curtis Wright 12/16/2021 Prepared By: 02:47PM Packaged Rooftop Builder 1.61 Page 36 of 36 ::x.uurram t -+>euearuGrviei+.yG.anee..mfuiuGuexscaa. tmteutGttnH ,..eeG4rN . .a ..ae:eta naWtHN3.t48MNilNd4lfNktiandtitl{ z w.dx..rr ,...., e ,..a,.. r a:raaameGyrsa.riseriseiAttdki{3NNdNix#rtrNaaefrH#.mx.4LaPrG G+wtif.aexrn» ilGnawmxxiumrxrtrea.... Crystal Distribution,Inc. 17560 Tyler Street NW Elk River, MN 55330 Phone:763.391.7790 CUSTOM CURB ADAPTERS Toll Free: 1.888.234.7001 CDI QUOTE #1837523 Date: 12/08/2021 Customer: Paul Luvaas (AIREFCO) Job Tag: curtis Customer PO: CURBS Line Quantity CDI Part # Description Tag A 1 1-4025-4021 Curb Adapter 1 Old Model:48SS036 New Model:48VLC36 Top Brace; Insulated Condenser Panel (where required); Fully Insulated (1" Duct Liner R Value 3.85) B 1 1-4025-4023 Curb Adapter 2 Old Model:48SS060 New Model:48VLC60 Top Brace; Insulated Condenser Panel (where required); Fully Insulated (1" Duct Liner R Value 3.85) C 1 1-4025-4023 Curb Adapter 3 Old Model:48SS048 New Model:48VLE48 Top Brace; Insulated Condenser Panel (where required); Fully Insulated (1" Duct Liner R Value 3.85) Thank you for choosing CDI, Josh Eastman OPTIONS: DIMENSIONED AND TOLERENCED PER ANSI Y14.5M-1982 REVISIONS MATERIAL: 18ga. GALV STEEL REV. ECO# DESCRIPTION DATE APPROVED INSULATED PANELS (WHERE REQUIRED) Attn: 1 INITIAL DRAWING 1" 1-1I2LB DUCT INSULATION (R VALUE 3.85) GASKET PROVIDED WITH CURB 1 1/2"ADDED TO EXISTING CURB O.D. Tag: • Approval: —RETURN00,....„.:„ , INSULATED .=3313/16" - COVER #„ ::, 12 1/4" �—2 1/4"21/4" - -a-11/141 EXISTING CURB LAYOUT ' _ SUPPLY— UPPLY -a- 13 1/2" 17 5/8" -w- 11 1/2" =- , -0- f 2 1/4" ,, I _ IL. L 2 1/4" 7.1 INSULATED COVER 18 5/16" RETURN SUPPLY 7 41" 46 1/16" 45" 30� J 1 5/8" I J II � 1 II I L I 5" 12"1 i I I 5" - — - 46 1/2" 42 1/2" THIS DRAWING&THE INFORMATION CONTAINED APPROVALS DATE TITLEIFILE NAME CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE THEREIN IS THE CONFIDENTIAL,PROPRIETARY OSWN - INFORMATION OF CRYSTAL DISTRIBUTION INC., 12/13/2019 1-4025-4021 LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION &MAY TROUT BE USED OR REPRODUCED G„EaK'' — WITHOUT THE APPROVAL OF CRYSTAL DISTRIBUTION,INC CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. ALL RIGHTS RESERVED DIMENSIONS ARE AS FOLLOWS:1.00in[25.40mm] *VERIFY EXISTING CURB APPROXIMATE ECO a: REV. *VERIFY SUPPLY AND RETOURN OPENINGS lRO ANG E �M �` w COnt d S Com CURB WEIGHT(LBS.) OPERATIONAL HEIGHT OF CDI ADAPTER IS 3 LESS THAN OVERALL CURB HEIGHT *NOTE ANY CHANGES PROECTION / ; t col 50.66 1 SHOWN. *CALL WITH ANY QUESTIONS or *FAX BACK IF DRAWING IS OK AS IS 1:... ..r7. 1-888-234-7001 SCALE: 1:15 SHEET: 1 OF 6 S:\CURBS CURB ADAPTERS\STOCK CURBS HEM\1-4025-4021-HEM\ OPTIONS: DIMENSIONED AND TOLERENCED PER ANSI Y14.5M-1982 REVISIONS MATERIAL: 18ga. GALV STEEL REV. ECO# DESCRIPTION DATE APPROVED INSULATED PANELS (WHERE REQUIRED) Attn: 1 INITIAL DRAWING 11/07/2008 . 1" 1-1/2LB DUCT INSULATION (R VALUE 3.85) 2 REMOVE TOP OUTER FLANGE 10/20/2011 GKF GASKET PROVIDED WITH CURB Tag: • 3 TOP BRACES ADJUST FROM 1 3/4 FLANGE TO 2 1/4"FOR 7/25/2014 CKK CARRIER DIMENTIONS 1 1/2"ADDED TO EXISTING CURB O.D. Approval: 4 UPDATED TO HEM STYLE 5/17/2021 ZLS INSULATED RETURN 2 1/4"i F 1 1/4" 2 1/4" COVER (TYP) �,� SUPPLY 17 5/8" 29" i 13 1/2" --N— 11 1/2" f — — i f 2 1/4" INSULATED 2 }4" COVER 18 5/16" RETURN SUPPLY // Z. 41" I 46 1/16" 42 3/16" 145" I I ir 1 7 5" 1 1 ` 14" 1 1 II 46 1/2" 1 (- 42 1/2" THIS DRAWING&THE INFORMATION CONTAINED APPROVALS DATE TITLE/FILE NAME: CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE THEREIN IS THE NFORMATIONOF CONFIDENTIAL, CRYSTALDISTRBOPRIETAR UTIION INC., °RAWNi zschelienberger 5/17/2021 LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION WIE USED OR RERODUCED TIHO T HAY OBE APPROVAL OF CRYSTAL DISTRIBUTION,INC. CHECKED 1-4025-4023 CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. ALL RIGHTS RESERVED DIMENSIONS ARE AS FOLLOWS:1.00 in[25.40 mm] "VERIFY EXISTING CURB D 011A APPROXIMATE ECO#: REV: 3" VERIFY SUPPLY AND RETOURN OPENINGS ,RO ANGLE "�"'+�` www.cdacu bso m CURB WEIGHT(LBS.] OPERATIONAL HEIGHT OF CDI ADAPTER IS LESS THAN OVERALL CURB HEIGHT NOTE ANY CHANGES pftOJECTION ; �� 52.55 1 SHOWN. *CALL WITH ANY QUESTIONS or "FAX BACK IF DRAWING IS OK AS IS ,,,.,., .,,.�i. .. 1-888-234-7001 SCALE: 1:15 I SHEET: 1 OF 9 S:\PRODUCTION\TURRET\STOCK CURBS\1-4025-4023\ OPTIONS: DIMENSIONED AND TOLERENCED PER ANSI Y14.5M-1982 REVISIONS MATERIAL: 18ga. GALV STEEL REV. ECO# DESCRIPTION DATE APPROVED INSULATED PANELS (WHERE REQUIRED) Attn: 1 INITIAL DRAWING 11/07/2008 . 1" 1-1/2LB DUCT INSULATION (R VALUE 3.85) 2 REMOVE TOP OUTER FLANGE 10/20/2011 GKF GASKET PROVIDED WITH CURB Tag: ' 3 TOP BRACES ADJUST FROM 1 3/4 FLANGE TO 2 1/4"FOR 7/25/2014 CKK 1 1/2"ADDED TO EXISTING CURB O.D. CARRIER DIMENTIONs Approval: 4 UPDATED TO HEM STYLE 5/17/2021 ZLS INSULATED RETURN 2 1/4" -.-- 1 1/4" 2 1/4" COVER 1-"-(TYP) / 7 �,/�' SUPPLY 1 rI 17 5/8" 29" -� 131/2" -*— 4 --1.- 11 1/2" -..— • - - i i �-2 1/4" INSULATED 21/4" COVER 18 5/16" RETURN SUPPLY ✓! 1 41" 46 1/16" 42 3/16" il L''' 45" t s� I 5" 1 I I I 14" I , 1 'I , 5„ 1— 46 1/2" t 42 1/2" THIS DRAWING&THE INFORMATION CONTAINED APPROVALS DATE TITLE/FILE NAME CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE THEREIN IS THE NOPRIETARY FORMATIONOFCCRYS CONFIDENTIAL, TALDIISTRIBUTION INC., DRAWN: ischelienbor9Er 5/17/2021 LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION &MAY NOT BE USED OR REPRODUCED �NECEEO 1-4025-4023 WITHOUT THE APPROVAL OF CRYSTAL DISTRIBUTION,INC. CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. ALL RIGHTS RESERVED DIMENSIONS ARE AS FOLLOWS:1.00 in[25.40mm] *VERIFY EXISTING CURB �,it% APPROXIMATE EGO n: *VERIFY SUPPLY AND RETURN OPENINGS RDANCLF i♦�# � www.cdicu COITtaCt S @ m CURB WEIGHT(LBS.) REV: OPERATIONAL HEIGHT OF CDI ADAPTER IS 3" LESS THAN OVERALL CURB HEIGHT *NOTE ANY CHANGES oRDIE�T,oN jr * t col SHOWN. *CALL WITH ANY QUESTIONS ,� -„ or *FAX BACK IF DRAWING IS OK AS IS *Ea*Ea li }.,. .,� .', 1-888-234-7001 5 .55 SCALE: 1:15 SHEET: 1 OF 9 S:\PRODUCTION\TURRET\STOCK CURBS\1-4025-4023\