Loading...
PFI2021-00448 IICITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT ■ , COMMUNITY DEVELOPMENT Permit#: PFI2021-00448 Date Issued: 01/03/2022 T I G A R.0 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: SEG867 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Ziply Fiber-W0897104 Project Description: SEG 867/Access HH on SW Johnson to splice fiber.Access HH on SW Tigard st hand trench 20'place 4"conduit and access MH SE corner of SW Tigard+SW Grant to splice Class of Work: FEES Type 1 -Utilities(gas, electric,data) Description Date Amount PFI Permit Fee 12/23/2021 $300.00 Owner: Total $300.00 REQUIRED INSPECTIONS Call 503-639-4175 for the IVR inspection request line or visit the City of PHONE: Tigard website at www.tigard-or.qov to schedule inspections online. Contractor: PHONE: Applicant: MICHELLE ROSE BOISE, ID 83713 PHONE: 2085764031 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: U ce,.,'ebti Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PFI2021-00448 Tvoe: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code,and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes,etc. shall be reinstalled or replaced,with like kind of material.Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept.of Transportation, FHWA, current edition,American Traffic Safety Services Association[ATSSA],and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices,flag persons, etc.,shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic,at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services:503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140 (Tri-Met)and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules,contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads,ditches,etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector,<Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance,and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22- DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may,at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing,of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements,shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other City of Tigard pH#: PFI2021-00448 ENGINEERING DEPARTMENT riGARD Public Facilities Improvement (PFI) Permit PROJECT INFORMATION TYPE OF WORK Project name: W0897104 ❑ TYPE 1—Franchise Utility Work Brief description of project: Access HH on SW Johnson to splice fiber, Performed by NWN,PGE, or utility agency Access HH on SW Tigard st hand trench 20' place 4"conduit, and ❑ TYPE2—ROWSidewaik/Driveway/Sewer Work performed for the purpose of. access MH SE corner of SW Tigard+SW Grant to splice SEG 867 • sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and Location (address if available): 9806 SW Tigard St main line tap 0 TYPE 3—Full Scale Development Work Tigard, OR 97223 performed with land use approval which includes any of the following • Subdivisions or Partitions APPLICANT INFORMATION • Street widening Name: Ziply Fiber- Michelle Rose • Mainline installation for sanitary sewer, storm sewer, Tigard water, and Tigard Mailing address: 6074 N Discovery Way Ste. 125 water service area City/State: Boise, ID Zip: 83713 ❑ TYPE a—small Cell Technology Phone: 208 576-4031 0 TYPE 5—Tigard Triangle Email: permitting@mountainitd.com Phone: NOTE: Type 1 and 2 applications may be emailed to rowpermitsCtigard-or.gov. Contact name: Phone: Email: CONTRACTOR INFORMATION ❑ Same as applicant Name: NorthSky Communication CCB Number: Mailing address: 11818 SE Mill Plain Blvd Ste 410 City/State: Vancouver, WA Zip: 98684 Phone: 503-975-6272 Email: pfrazier@northskycomm.com ENGINEER INFORMATION Name: Russ Wells Mailing address: 4155 SW Cedar Hills Blvd City/State: Beaverton. OR Zip: 97005 Phone: 503-643-1001 Email: russell.wells@ziply.com ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ n/a (within the public right-of-way) Is work related to a LAND USE DECISION? ❑Yes DI No Case number: City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee" and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I,the applicant,certify that: • To the best of my knowledge, all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. Gu - /6:14 Michelle Rose 12/17/2021 Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY Case No: PFI2021-00448 Permit fee: 5°n-6)42 Received by: NT Date: 12/20/21 Approved by: �s—P�/ .�J Date: "2/21 /Z6 Z/ Notified by: Date: _1141,1110/1 City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7% (less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR STAFF USE ONLY FOR STAFF USE ONLY TYPE 4: SMALL WIRELESS FACILITY TYPE 1—3:DETAILED SUBMITTAL CHECKLIST REQUIREMENTS Does applicant have a right-of-way license? 0 Yes 0 No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal LI Dimensions considered?(check all that apply): 0 Small Cell 0 Macro ❑ Street Name Flow many install sites are proposed as part of this permit ❑ Site ddress application? TYPE 3-Must provide 4 sets of plans (sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: 0 Public Right-of-Way 0 Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes (City,Water,Sewer,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineer's Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval City of Tigard • 13125 SW I Iall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 3 of 4 9 II- .. y- Edge ofPavement �-- Ditch —I.'Streetlight 1 _ •�•�•�•—•—•—._r�•_ III'14to f ' lia�v Daa4' _•r..�.„,, ® 7-C 1 r n.. �� o D 1 • T"YriOTZ rd-Ter7FMiTie" I I 1 g` I Existing House 1 ~' E1 j Existing 1 �I V-1 Driveway I-I 3I I y 0I CI w I • /I 3I a°O i • 61 I 1 Existing Shop I cA Sas Powerpole I 1 = I co I o Q �`■ la 95' i o • I ( ) I Firs Hydrant(F H) • I I I iI Scale: 'I"=30' I I I I I j TYPE 1 AND TYPE 2: MINIUM SKETCH REQUIREMENTS (Put N/A if nin applicahlc) North arrow Property lines&dimensions Existing utilities locations (sewer,storm,water) Street&street names All existing structures Proposed work Existing curb or edge of pavement Utility& street light poles Existing S/W or D/W apron Slope of property Trees City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www tigard-or.gov • 503-718-2421 • Page 4 of 4 1 a I 1 0 ro 8 U S x 8 8 8 N o� 8 I Single Flagger Operation „ I a o N for Low Volumes (Optional) c a ti r (ADT c 400) (n'� 41 '. rn 8 o g "1'o RAWER BE O O I. -r i PREPARED ONE LANE fC w' �, 1 •se t•.>,c t. TO STOP ROAD 8 O g E •1 i 4. 1 ,.. 1 AHEADOf R. A �'. 1 ROAD lail g E r:i § nva . . . . e 6_47 ppO N ur , WORK l , l We: n®.w.e.\� y M N y GOWWO Opq � T ® lYOY'I. , . F.--A- a s -� f k _. 7 mile -n Max. a • •• •• r• •• • — — — to • • z, • 110. to ea f0 LC_Jf66 \ Suffer / Protection Vehicle ROAD / / \\ wi TMA(both Optional) WORK See Chapter 4 0 AHEAD 0) BE • ONE LANE PREPARED t,9 ROAD TO STOP Two Flagger Operation 3 a m of (Optional) m O al AnpA-Z'auel-e, \ �J CUSTOMER: \ ORDER ISSUED' DUE: -` ADDRESS' SERVICE TYPE: 4.. ASSHiMlENl: y ..... TEST: dB 9 kHz ,111� Al - SPECIAL NOTES: UNITS/ACCT CODES \ 3 .__ _ REVISIONS .4 1 ZIP! / METRO E 9806 TIGARD ST PROJECT 5904207419 CD - EatCCC DIRK1E.ARI OWN DAIfl TI Rw1E LMEILS Remainmain„we SOLE I:X15.2 1 DSTRt:- vI OF 5 • 51351-W0897104-5504207-479 METRO E 9806 SW TIGARD ST - TIGARD OR Ziply Fiber Contacts now Dr/]s/2D21 Engineer Order.855R3393376 RUSS WELLS Cirtun lD ARNTyr22O]O//Nw c/ service:3031.5oeo MATERIALS 503-312-7330 Customer End User:Tmmpk Inspector: Address:;uesw Tlprd sy Portland,OR TOM WATSON Eada^de:TOO/5335] 6 PORT TENNNAL 50'TAM,' o uste w3yc3 12 FLAT FIBER oR 37Y 503-998-2588 LCON: Desired rue omr a/]s/n 4'CONOUIT. R NS: LION: 202' ROBYN RUSSEL LITE SUEM MO.615TMNi SItt TFl RO=<]5235Y133 111 erd SPLICIN /P5 Pade., •516I158603AlaAR.C34 DAV C CARNLEY came=2188194• DAVID CARNLEY DU.111WOWT.Copper Tlen.l,wR,amn,D.,3-31 971-940-9000 count ripper Term:x/A For:= FibeI WA Cara:CLLI C TGRDCRXA UNITS UNITS/ACCT CODES ail CODE I:E] SPUCE FIBER UG 1 1OUI6 a..eon rrdlwu IPReaemeWOnep.r:RED IIRWIRR-FQeR]ATDm R1aa,55 Rawl. SPLICE UG1m2 THAN 48.8 PLACING Pn30tA osnwmtkk.050 4207-47ee RE A R TEST COSTING PLACING I4 EC'R�12 On 842,E respond with KO Ott WTATG4—FleMirN6EgYrsarliT REARRANGE FJ051lIG CLOSURE NON—READY ACCESS.J PLACING MSPECIDR�2 S058 oF/Naae respond with KO Dee ASAP: SPLICING.12 ]el.Awo: SPLICE F 2421.201 TGROOlxate .•9806 Hard-HA,at Ow St,PmxtW,oR SPLICE FIBERR ISNAL LESao THAN N—R PwneMelmMe con uit RwrertM twmmer'sbmA'an.RoreTemR from lire Hand-Molem Ryb55Tand Continue the Rme/M1entlremTtResMe0t0m pWbRIR REARRANGE EXISTING CLOSURE Ndl—READY ACCESS-1 Race a C.5.Plattltr a conduit In Iardrtnle. Pulls fiber er Orel,n,lhe the WOclteoeghd-Role the new tend jt 55.56m Fwthe 60w NE nninaLrmYul. PLACID 2422IStS 201 CO Loot.trrompaml NOMA EammWR the nea mmrnm gmuOOOO rmelemw.5 RACED 51 ED COUNT 1TR2122. Lit mere Rewne.Nde amNlnlmNMr Run xamsxa5]o sw3omem N.Rican.ganellwlreeeerwnF¢af.ss3 aTolmotM Inc RACE PULTECOm CABLE Moe awrom WOEbcm]fAbReomu PLACE/PULL FlBER GABLE N lL)OIAT.XI2 Tee Nit,an tuMPOFextra:100.51.0-IUA,11-12 5,55. Nate NIDaM rum.apserv¢e on irleai,gla-Im00s,5s. Sam-F: Fiber-Feeder assignment 1:3011A70 TGROMM SOW Bar RN e01-19-12. FIND-DMrlbNlm assignment:Nlda],5555 Nw�aw.� •e+eY^MO x :.roes t...Q y ' f v,a.a.hMe%Orsr •. 1 was O,. REVISIONS • N _ GEKERAL CONSTRUCTOR ROTES MANY FACl1TIE5 ANO CABLES ME GUTTED FOR CLEARITY.ALWAYS UTILIZE ALL PERSONAL 'u PPE MONDE APPROVED TRAFFIC CONTRA PLAN.ALWAYS GET LOCATES BEFORE MIT AND ALL DIGGING.ATIENTIDI HIGH VOLTAGE OVER HEAD POKER ALONG MS ENTIRE WON( WA.ANY CHANGES OR ADOITONS NEED TO BE PEE—APPROVED BY TIE LOCAL ENGINEM.FOLLOW ALL LOCAL AND FEDERAL SAFETY LAWS.UTILIZE ALL IESTNG AND •.i/ SAFETY EOUP.CLEAN UP ANT WORK WAS BEFORE LEASTIG TO TE NEXT LOCATOR. ENSUE GRADE AND GROUND IS REPAIRED.ENSURE THAT ALL REQUITED PERMITS ME O .. WIRED AND GI HAND ziply Fiber METRO E 9806 TIGARD ST TNOJECT Nu R 5504207-479 `Flml .AM OIRDTGVO .PAIN N.T. 04Tt lA®L RT15 stir RIBINIMLOE9Td TR 1212011 FICHE— RE PDC OW— WAIL LINA TMEEIRLL— GRG i aF 5 '/ (PLACE RED STRAPS AT HUB) © /7(FC2041,670 TO H4005,55) 936 06.2020 / 500241 C210283551 144—FlBER 144 , PORTLAND GENERAL ELECTRIC R / TGRDORXA H4005,1-66+ / , XD,67-72+ TGRDORXA H4005,73-132+ X0,133-144 `.\ /a DeR:0709/7075 Order:PSR 3393374 \ a CroatID I/117N/1 1m 10//NWFV ` SeMce:1RMB ElA \ / Customer Gal User;Transpak` Address:9 SWlVedSt,Portland,OR• 0 / Exchanger TGRD/51351/ Access HH to � owcao eVeta r smesired Due Dale:6/19/21 splice / LOON: ` SITE CON a STUART SII.R l SITE TEL NO=4157 312222 a. as a /... SITE EMAIL=STUAgr.91M15@TRANSIn6.COM q, der' Carrier 2ply Retail 'As . DSATY:2180190-Copper der 1-4,389',Fiber Tler 1•514' 0.-. . /4 '.1R Ea611n6 Copper Term:N/A 9 am TGRDORXA H4005 t (PLACE RED STRAPS AT HUB) Count: N/A FDH CABINET 48/432 �A �l\� // FC2041,670 TO H4005,55) Fiber Count: UNITS/ACCTCODES IN:TGRDORXA FC2041,849-854+ v ( au CODE 1:T6RDDRKA XD,1-32+ �\ 504 10.2006 CW CODE 2: XD.222-437+ TA/ 144 eea.erwn Famhles Reserve•'ter JUNI PER PER•F¢n61,670 to x m aao5,SS Pel. TGRDORXA H4005,1-66+ OSP Work Oren:OSP WO Required TGRDORXA FC2041.655-662 X0,67-72+ varasset ne,el:6504207-470/W0897104—Fielding R Engheenng OUT:TGRDORXA H4005,1-432 /' N. TGRDORXA H4005,73-132+ OSP please respond with an ECD Date ASAP: `� X0,133-144 N1a, (PLACE RED STRAPS AT HI /� T�tethe Hana65WTprdro St,tortae cuss Locate the Hand-Hole at[M Front d the customary location_0mrefrrentD ham the Hatl-Mole to (FC2041.670 TO H4005, • Ped4557 and continue the Bore/Trench along the side or the building to Ped-11545.Place a conduit In 1404 06.20 7 the trench. Place a 6-poll Terminal In the NaN.Hale and Splice IseW5,55-56 to PMY16 PonY2 of the terminal. 144—Fl � BER 1 \ � MR.Fiber Drop from the MPDEtnmugh the new conduit to Fortelorthe new terminal. TGRDORXA / Locate e Nerd-Hole adjacent to Fiber nub H a 4aa5 9910 SW Johnson St.Heat-up additional Feeder � XD.25-96+ � Count FC2041,663-670 imo the Hub. TGRDORXA FC2041,649-696 / ` Place a Red Juniper from=041,67DW NamssS. \ Test Fibers ham MPDE back to TGRDORYA FDF 002-19-22. /' Place DID and turn-up service on FC7041,67I-64005,5S. `� Bruno eg Fiber-Feeder assignment:FQd1,670 to TONDORKA SABO Bev:EDF 001.19-32. /a Fiber-Dis00Nlon assignment:H4005.55 Plisse contact me with a"y questions / FIELD Nanlne Could not local a copper terminal in the building and we searched the whole taRa le according to ICON. /' I did finds 25 pr.Cable de-sheathed just hanging nut of the ceiling In timeserver room,which Is where they want this to go.The custom seemed willing to place rated conduit so we role run me drop to REVISIONS theo carver room-WE will need too our bore horn o facilities too OED 6557,and hem Peal 6557 to PED 11595.I poked in the Hand Hole where FT:17B502 slaws to be in frogs but it's there.The haMhole and the Reds are all direct buried.Peal 116461s located about mid way on the west side of the building by the steps.In the server roam there Is mounting space and available power• ziply ••cAURON •• r�{\ tarp,vargw Pew [Mi.oohed METRO E 9806 TIGARD ST PROxcr 5591201dT9 cam — 'STOP and LOOK Uv' p NuieRFR: Eu%WR.ORPLPGVA 1 URDNMR DM PffiNIfR15 O M21RY0DEWJR 1=21 NCNB RE V C JOIE 1.100 ray D11567— ins J OF 5 1 rdt0v_ FNG _ 10 — •• CAUTION •• Date:07/19/2021 "AH•W'0 ro•. Order:P5R 3393374 r '[.l R•Uwe Circuit ID 43A1/01/722010//NVJFC/ ' Service,100FAB DA "��� Customer Er.d User Trampak Address:98065W Tigard R.Portland,OR 'STOP and LOOK UP' Exchange:TGRD/S1351 OA/CO:D41/963 Customer Desired Due Date:8/19/21 I LCON: 511E CON 510011T SIMS SITE TEL NO=4167312222 I SITE EMAIL a STUART.SIMSMTPANSPAK.COM Carder:IIp1F Retail MARL 2188194-Capper Tier 1.4,389',Fiber Der 1.314' Edam,Capper Term NIA Count t EDT: N/A \ Flnttfpnt CUJ CODE 1:TGRDOR%A Z Rea CODE 2: = Beaverton Facilities Reserve Fiber:RED JUMPER-F62041,670 to H4005,55 Portal. equired „, Ear Wart Omer:6O 05P WO20—479 I\ ,\ Access HH trench Ovessea erespo6042 enlCDDateAIAP. 04—Flelmnea Enemeenne 05P Solution, respond with an FCD Date ASAP. 20' +place 4" it Conduit to PED " T Ma A-9606 sw Tram St,Portland,OR \\ V Locate the a Bo e/Te none none of the at the building i Iaoto red-1154en[n team hod HaMthe t eo Ped 655]antl commu6p rt TnRrenm ald�theHioe and SemSe--AoaotAl Place&amia the UNITS/ACCT CODES `\ -...M x Place F6part Tpfront l inthe the WO( (through one trwrodultto Ponta Po dal OPnrcr tithe terminal. \ `\` de vane Fiber Drop from me MPDFthmugn me new nneuhp vonal of the terminal.xw locate the Hand-Hole adjacent to Fiber Hub H4001 at 9910 Swlohnson Si neat-up additional Feeder Court \ Oa Y ti FCMI41,663-001nt0 the Hun OH ,`� Place a Red Jumper from FCIlall,670 to H4005,55. \ p _s: 09 Teat Elbert from MPO ,E to TGROORX*FDF 002-19-22. `\ A'X, 'J��Q }P Place Nil and turn-up service on FE2141,670-1M005,55. Summer . (EXISTING COUNTS) lb Fiber Reeder assignment K2M1}TOlo TGRDOR11A 5160 Ban:FOE 001-19-SL ` `, • Fiber-Diao-lbunen eengnmefl H4005,55 366 10.2006 '� Please contact me with any apeseons YJD 144 LEAVE 50'OIL AT HH `` • (TGRDOR)A H4005,1-66+) FOP �,�BBGTD 6557 REM NOTES: - X0,87-72+ BBGTD 4,2051-2075 Could not locate a copper terminal In the building and we searched the wet*building according to RCON.Idw TORDORXA H4005,75-984 SOS Sa f \ and ais or.Cable de-slwathM lust hanging out of the ceding In thek seine coom..hkh is white they vain this XD,97-144 WlFee'_, \ to go.The customer seemed willing to pace EMT rated toilet to we could nn lie drop to Mee server roan.WE .+vav / will need to bore front our facilities to PED 6557,and from Pad 6557 to PED 11545.1 looked m the land Hole (NEW COUNTS) St / 3. �\ where FT:178502 shows to he m nags but it's not here.The handwrite and the Ards are all direct buried.Ped 36610.20D6 .• j^ �4f 11545I located about ma vas on the west Side of the dewing,by the steps.In the server roan there is YJD 144 e AY \,yy. mourning space and available power. TORDORXA H4005,1-64 ItLT M 7mr55-58 • i /A. TGi 04 \ TORDORXA N X067-72+ `���.. /c``i kq 7)?A7R. `\_\ TGRDORXA H4005.73-96+ I- ? r LEAVE 100'C .AT WOE 4=-1 we is \ Access MH to REVISIONS '` . CUSTOMER TO PLACE EMT TO SERVER Row / Rx �m \_\ splice >'/ 7j545/N F/e2p(PL(FC 041 6670 TO H4005.5) / `STRAPS AT HUB) \ YJD 144 372' / TGRDORXA H4005,1-66+ `\ UNK_SERVICE DROP 12 r TGRDORXA H40055,737100+ AV9 \ TGRDORXA H4005,55+ / ///:.-.4 c _\W'/+ S'T Z) F lY XD,2-12 X0,101-144 (12 FLAT FIBER DROP) it r `\�O ibr- (PLACE/PULL INTO DUCT-202') (PLACE RED STRAPS AT NUB) in (LEAVE SO' COIL AT HH) (F'C2041,670 TO H4005,55) a �' METRO E 9806 TIGARD ST (LEAVE 100' COIL AT MPOE) N7 936 06.2020 144—FIBER 144 TGRDORXA H4005,1-66+ PROJECT CONEA — X0,67-72+ HIPARH 5504201479 COMM ORPPL 1Wm TORDORXA N4005.73-132+/j �///'''��� L""""wE CM'RE R�F11N Ia1ROEaM XD,133-144 / unvnl — L SUE 1l100 IAYCS11RT— MI6 s f py;OF 5 12 FLAT FIBER DROP: 372' UNK_SER'ACE DROP 12 TGRDORXA H4005,55+ XD,2-12 (12 FLAT FIBER DROP) (PLACE/PULL INTO DUCT-202') (LEAVE 50' COIL AT HH) (LEAVE 100' COIL AT MPOE) ,I UNITS/ACCT CODES TERMINALS: TERM 891502 6 PORT TERMINAL 50' TAIL LOTS/ADDRESSES 1. 9806 SW TIGARD ST 2. VACANT/RESERVED 3. VACANT/RESERVED 4. VACANT/RESERVED 5. VACAMT/RESERVED 6. VACANT/RESERVED REVISIONS 1 zipiy METRO E 9806 TIGARD ST RROxcr 5544207479 WIRER EOM OIE OA RCIVI9 01550OM BIER AUSSEL011115 QRY.M9lIMIFIRJ E EOIM 129AQ1 SEX-- NE $(/IE: I'191 TAS%1R1,'1'- MC -5 OF 5 iM9P- ANG - SEC -