Report r OFFICE COPY OFFICE COPY R r .4 OP TIGARD, • .. . RECEIVED FOR CODE COMPLIANCE JANIENVIlv d�)`2 s i I j . , i!P1(a oil �.,N dt F Ps ana . .--o0 - ILI Jersey Mike's eii t 17Om' Prf :-c c J4 r -/ Ansul R-102 liquid Os , UL-300 fire suppression Dates c 7 2 ) — 10"round system _^'�- , exhaust 1 duct max flow points 11 i \ill Lr system using 10 I—I fire system piped Heat Detection \ (450 deg) in 3I8" black pipe Ansul R-102 3 gallon fire fuel shut off 3/4" system gas valve 4 5'hood —11.5"— 25.5" 11.5" (p1 245 4. — 245 max from edge of pull station nozzle height no more cooking 10'on path than 20"above appliance surface — of egress Placard IP 1\\ffl Upon system activation k class fire extinguisher gas located within 30'of the exhaust fan shall valve the cooking area & remain on and the fuel, 314" in the path of egress power and makeup air shall shut down. 48"grill top Pye Barker Fire & Safety Jersey Mike's 18260 SW 100th Ct. 11705 SW Pacific Hwy Tualatin, OR. 97062 Tigard, OR. 97223 (503)691-9000 (503) 754-4547 Greg Heath Bob Keatley CCB# 231264 i �~�����K~� ' �_� ���� ����� - 6-1D3 Restaurant Fire Suppression Manual j.8h 13 7027 SECTION 4-SYSTEM DESIGN ULEX347O ULCEX347O _ 2014-SEP-01 RE)/ n PAGE 4-1 . 1rUfp,li�/<17' 01,"li&�'C SYSTEM DESIGN GENERAL INFORMATION The ANSULR-l0J Restaurant Fire Suppression System may Uo 1. Nozzles must belocated 2-8 in. (51-203 mm)into the center used nnm number of different types of restaurant cooking upp|i- of the duct opening,discharging up.GeeFigue4-1. mnceo and hood and duct oon§gurabono.The design inhonnabon listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the A-102 system must be trained and hold a current ANSUL certificate inunR-1O2 training program. The R'102 and the PIRANHA systems use compatible agents and components' /henafoe, they may be used together for cooking apA|ianoe, hood, and duct pmWection. The primary AUTO/NAN Release can be either an R'102 or a PIRANHA | 4UTOK4AN Release and can actuate up(o two additional R'lU2 or P|FV\NMA Regulated Actuators. In systems utilizing a 101 2-8 IN, ' remote release, any combination of the maximum number of (51-203mM) U regulated actuators can baused. � U ^ Both systems must actuate simultaneously. ^ Each system must ue designed and installed per its appropri- ate F�(3U�� *-1 mmnv�. ^ Adjacent appliances requiring protection must be protected 2 In installations whom u UL assembly damper u�omm� is with the same type of system, either R'102 or PIRANHA, ' unless the center-to-center up' �ng between the a�ame ' �mp|oy*d. the du nozzle can be installed beyond the 8 ' R-102ang PIRANHA nozzles iunoless than36 in. (914mm in. (203 mm) maximum. to a point just beyond the dumper ^ When appliances are protected with R'102 nozzles, � oomem� th��w4Unotn interfere with the damper. Exceeding »uodandoonne��0ductabwvmth000app|ienm� cmnncu be-- the maximum »fU in. (2O3 mm) in this way will not void the protected with PIRANHA nozzles. UL listing of the system. — ^ Mixing systems ina common plenum isnot allowed, 8. Previously listed three flow number and five flow number One of the key elements for restaurant fire protection ioacorrect duct protection detailed in earlier published manual(Part No. system design. This section is divided into 10 sub-sections: 4,8V87-06)can also still bautilized. Nozzle Placement Requirements,Tank Quantity Requirements, DUCT SIZES UPTO§0 IN. (127Vmm) Actuation and Expellant Gas Line Rmquinam*ntm, Distribution PERIMETER/18IN. (486mm) DIAMETER Piping Requirements, Detection System Requirements, Manual pu|| Station Requirements, Mechanical Gas Valve ^ One 1VV nozzle=one flow number Requirements, Electrical $um Valve Requirements, Electrical . 50 in. (1270 mm)perimeter maximum Switch Requirements, and Pressure Svvhnh Requirements. Each of these sections must be completed before attempting ^ 1Gin' (4�$mm)diam�ermaximum any installation. System design sketches should be made o/all aspects of design for reference during inwhd|eUon. DUCT SIZES UpT] 10O IN. (2540mm) pERiKAETER/32 IN. (812 mm) DIAMETER NOZZLE PLACEMENT REQUIREMENTS ` One 2YV nozzle=two flow numbers This section gives guidelines for nozzle typw, positioning' and . 100in (2540 mm)pehnenarmaximum quon�yfor du/�. p{enum, and individual appliance protection. ' This section must be completed before tank nhqumn' ` ��in� (�12m/n) diameter maximum btYondpiping requirements. The chart below shows the maximum protection available from Duct Protection-Single Nozzle each duct nozzle. 3.0 Gallon 1.58al|on All duct protection isUL listed without limitation uf maximum duct Description System System length(unlimited length .This includes all varieties cfductvo�� ��x ��nop� 6 � � w/on�~w, � /� ��/nouv��mmum�v��nw/m��o o»«wozz* Maximum Maximum the hohronta!anmgu��v��ginopuona| benda� 10nm' (o5m/mrn) 1oo in. <eawornm> Perimeter Perimeter Note: Ducts from multiple nmo*e connected to a common / ductwork must be protected In oump|isnom with NFpA 96 and 1nVNoz�k» Maximum Maximum �all local codes. 50 in. (1270mm) 50 in. (180mm) -- TheR'1 02 system uses different duct nozzles depending onthe Perimeter Perimeter size of duct being protected. SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-2 REV. 11 2014-SEP-01 Duct Protection-Multiple Nozzle • Read over from the 8.0 in. (203 mm) line on the table to the 1 W Module column. At that point, the chart shows that the "B" ©UCT SIZES UP TO 135 IN. (3429 mm) PERIMETER- THREE FLOW OPTION module length for the 1W nozzle can be 22.0 in. (558 mm). Center the 1W nozzle in that module. The 2W module can now be • One 1W nozzle and one 2W nozzle=three flow numbers Centered within the remaining module. • 135 in. (3429 mm) perimeter maximum • No round duct option available • Follow design table in Figure 4-2 to determine maximum module size for each nozzle 1W Module 2W Module Side A Side B Side B Side B Maximum Maximum Maximum Maximum in. (mm) in. (mm) in. (mm) w. (mm) 4 (101) 60.0 (1524) 23.0 (584) 37.0 (939) 5 (127) 60.0 (1524) 23.0 (584) 37.0 (939) 6 (151) 59.5 (1511) 22.5 (571) 37.0 (939) 7 (177) 59.0 (1498) 22.0 (558) 37.0 (939) 8 (203) 58.5 (1485) 22.0 (558) 36.5 (927) 9 (228) 58.0 (1473) 21.5 (546) 36.5 (927) 10 (254) 57.0 (1447) 21.0 (533) 36.0 (914) 11 (279) 56.0 (1422) 20.5 (520) 35,5 (901) 12 (304) 55.5 (1409) 20.0 (508) 35.5 (901) 13 (330) 54.5 (1384) 19.5 (495) 35.0 (889) 14 (355) 53.5 (1358) 18.5 (469) 35.0 (889) 15 (381) 52.0 (1320) 18.0 (457) 34.0 (883) 16 (406) 51.0 (1295) 17.0 (431) 34.0 (863) 17 (431) 49.5 (1257) 16.0 (406) 33.5 (850) 18 (457) 47.5 (1206) 14.5 (368) 33.0 (S3$) 19 (482) 46.0 (1168) 13.5 (342) 32.5 (825) 20 (508) 43.5 (1104) 12.0 (304) 31.7 (805) 21 (533) 41.0 (1041) 10.0 (254) 31.0 (787) 22 (558) 38.0 (965) 7.5 (190) 30.5 (774) 23 (584) 33.5 (850) 4.0 (101) 29.5 (749) 4 1 Side B I Side A • 11 W ! , � 2W FIGURE 4-2 oossx^ Example: Protection is required for a duct that has an "A' dimension of 8 in. (203 mm)wide and a"B'dimension of 55 in. (1397 mm)long. Referring to the table in Figure 2. if the "A" dimension is 8 in. (203 mm). the "B" dimension must not exceed 58.5 in. (1485 mm). In this example, the "B" dimension is 55 in. (1397 mm), therefore, this duct can be protected with a three flow application. R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-3 ,-;--- Duct Protection-Multiple Nozzle(Continued) When working with Chart 4-2,one half of the quantity of nozzles determined must be equally positioned in the top half of the DUCT SIZES GREATER THAN 100 IN. (2540 mm) area of the duct and the remaining half of the nozzles must be PERIMETER positioned in the bottom half of the duct area. • Ducts over 100 in. (2540 mm) perimeter may be modularized Example: The duct to be protected has a Side "AC of 40 in. using 2W nozzles (1016 mm)and a Side"B"of 60 in. (1524 mm). Referring to the design chart, this duct requires four nozzles. One half of 4 =2. • No round duct option available Therefore,two nozzles must be equally positioned in each of the • Follow the design chart to determine maximum module size two duct areas.See Figure 4-3. for each 2W nozzle SIDE'IV • When determining number of nozzles required,it is sometimes 30 IN.(782 mm) 30 IN.(762 mm) — an advantage to check the chart using the shortest,side as I Side 'A" and then recheck it using the longest side as Side 20 IN. • • 'A."This comparison may reveal a need for a lesser quantity (508 rrtm) of nozzles one way versus the other way. SCE 40 IN, ------ - - - - -- (10 6 mm) When working with Chart 4-1, the quantity of nozzles deter- I 20 IN. • • mined must be equally divided within the duct area. (508 mm) 1 CHART 4-1 (1 SO IN. 524 mm) s FIGURE 4-3 COMM A In. • • • SIDE'B cm i 25,26127,16 2030 31 32 i 33 34 35i 36 37 38 39 4041 42 43 41„45 44.47,46 4C 93 51152,53 54 55 56 57 58 59 80 51 62 63,64 65 65 87 68 8570_7.1-72 c. 64 Ws 71 74 76 79 81 84 86 89 t 81 64 57 93102101107 .:112 114117 1191a1241V 1,Vh32,136137,1.931.42.'146147 160162156 157 leoldrieslas 1173 M178180183 cm, 4 i [ 10 - ' ' , r-, 1 ' , 13 , --, r e 1 15 7 r 8 2 . a 20 1 re 25 a 12 i i 30 13 33. to 1 ' 16_ 1 1 r-I 35 ., ' i6 , Iii SIDE 17 , , 'A" le -.1 a In. 19 , r 0 20 1 11 53 1.3.2 r ' I ' ' i , r .., 59 1 24 r- 1 25 94 . 251 f es i ,---' 3 I 1 a r ; , 28 I i 1 _ 17—, i N 30 1 i 1, —I . , _ 1 1 , _ I 78 , i - 1 ' 81 32' I I ' 1 33, I I 34 1 . J. I I , 4 , , , , I 86 ,3r—r 1 } ,' 1 ' 1 1 _ $ i ' 1 _ 8 1 . 579 89 91 CHART 4-2 s A" • • • • • • NOTE:NOZZLE QUANTITIES LISTED IN CHART 4-2 MUST BE EQUALLY DIVIDED INTO EACH OF THE TWO DUCT MODULES, 118_ 1 II1 _ i _ 1 37 , 64 a i 97 20i 4 3 E8 ...1- - .._, :--or, i 2 , 4 42 ' . , . 1134, 167 43 6 'Ter, 44 45 I 4 112' ,114 1/1 ! j..' -1 , . . . • 1...1 . 1 lin lid 006612 ..1.,06.1,14....."..............!,*.XiiiPaiIi.464WIr1M,Wil.41447, Jakkhieliroawvakarsiarvernwbor4rktowtorma/6401 SECTION 4—SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-4 REV. 11 2014-SEP-01 .._ Transition Protection Transitions are protected at a point in the transition where the The 1/2N nozzle must be centered 10 to 26 in. (254 to 660 mm) perimeter or the diameter is equal to or less than the maximum below the precipitator and aimed to discharge at the center of size duct that can be protected.The nozzle(s) must be located each precipitator cell. However, if it is physically impossible to in the center of the area at that point, or center of the module mount the nozzle at 10 to 26 in. (254 to 660 mm)due to precip- protected when more than one duct nozzle is required. Note: itator placement, the nozzle may be mounted closer than 10 in. Nozzles to protect ducts with a transition that is more than (254 mm). See Figure 4-5. 4 ft (1.2 m) in height, will be required to be positioned in the opening of the transition from the hood 2 to 8 in. (50 Ir. SEE FOR to 203 mm) into the opening using standard duct nozzle design parameters, See Figure 4-4. DUCT DUCT 1 i NO NOZZLE NOZZ-E PROTECTION Ilii 0 0 I I IL011 DUCT II ...41 i TRANSITION ,....... ii.."..-...., PRECIPITATOR I/ . r 111.111111111 --7 10-2E IN' (254-0S0 mrn) (14.217,) ilotallosi 4 1 mAi- poo. ' liql '1--17 / NOELS POR PRECIPITATOR PROTECTION FIGURE 4-4 .IF PMr'SfCALL.10TEZ04SSIBLE0AITN,1(0 TO.n2:)IN.(254 TO ex nyn).NOZZLE MAY BE 033,74 FIGURE 4-5 c.30,0e Electrostatic Precipitator Protection Note: For protection of Pollution Control Units (PCUs) or air Some restaurant ventilating ducts have an electrostatic precip- scrubbers with or without ESPs, contact Technical Services for itator installed at or near the base. These precipitators are non-UL listed recommended application. generally small and are used to aid in the cleaning of exhaust air. Ducts with precipitators located at or near the base can be protected using duct nozzle(s) above the precipitator and 1/2N nozzle(s) for the precipitator. One 1/2N nozzle must be used I.for each cell being protected. This nozzle is stamped with 1/2N, indicating that it is a 1/2-flow nozzle and must be counted as 1/2 flow number. When protecting ducts equipped with precipitators, the duct nozzle(s) must be installed above the precipitator and aimed to discharge downstream. If the area above the precipitator is a duct,the nozzle(s)must be positioned according to duct protec- tion guidelines. if the area above the precipitator is a transition, the transition guidelines must be followed. __, R-102 Restaurant Fire Suppression Manual , SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-5 • Plenum Protection Option 2:The 1W nozzle must be placed perpendicular,8-12 in. ' (203-304 mm)from the face of the filter and angled to The R-102 system uses the 1W nozzle or the 1N nozzle for the center of the filter. The nozzle tip must be within plenum protection. The 1W nozzle is stamped with 1W and 2 in.(50 mm)from the perpendicular center line of the *the 1N nozzle is stamped with 1N, indicating they we one-flow filter. See Figure 4-8. nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be 12 IN (305 mrn) protected regardless of filter length, MAXIMUM •It IN. Adhb,N VERTICAL PROTECTION-GENERAL (101 MN 1W NOZZLE-SINGLE AND"V"BANK PROTECTION ow : a IN (204 Mr) MINIMUM One 1W nozzle will protect 4 linear feet(1.2 m)of plenum. The maximum distance from the end of the hood to the first and last NOZZLE TIP I ,iriir nozzle must be no more than 2 ft(0.6 m).After the first nozzle, MUST BE WIN .... any additional nozzles must be positioned at a maximum of 4 ft I ,Atr • (1.2 m) apart down the entire length of the plenum.The plenum IL - me" width must not exceed 4 ft(1.2 m).(The 1W nozzle can be used on single or V-bank filter arrangements.)See Figure 4-6. FIGURE 4-8 =co 2 PT(0 6 m) , MAXIMUM 1 HORIZONTAL PROTECTION-OPTION 1 4 FT(12 tT1) 1N NOZZLE SINGLE BANK PROTECTION a FT( 2 MAXIMUM 4FT(12m) 2 FT(0.6„a)MAXIMUM - MAXIMUM * One 1N nozzle will protect 10 linear feet(3.0 m)of single fitter bank MAx plenum.The nozzle(s)must be mounted in the plenum, 2 to 4 in. ,.-,.,.., (50 to 102 mm)from the face of the fitter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in.(0-152 mm)from the end of the hood to .... 001,,,,/,., ,;,::.a. k„, .: ,,,.•• •" the tip of the nozzle.See Figure 4-9. ,,,:::!,3,-111011,000;Idilill.111%':;;5!.7•• '''''' 0 .:;."..........---' I••°7-.:;°— -,,,,_ . '''' ...:;...?0,e, , -------- 2-4 IN 10 FT(30 ml .. (50-12 Dm) MAXIMUM ..--""---....'- .. , 1 oe 0, FIGURE 4-6 , . 0:097 00O231 When protecting plenums with the 1W nozzle, two options of coverage are available: Option 1: The 1W nozzle must be on the center line of the 11 •••••••••0•00/ single or"V"bank filter and positioned within 1-20 in. k4,, ,, (26-508 mm) above the top edge of the filter. See Figure 4-7. I" $ FIGURE 4-9 I i , 20 IN (508 rnm) MAXIMUM I • t ILt!2U6MIncn) -,:, .-; N1 l , 20 it+ (508 mrn) MAXIMUM .;.•!::;:;.' 41Z4I1,(42U6Mml") ..„ . 4.• V:. FIGURE 4-7 compa . , - ... .• SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-6 REV. 11 2014-SEP-01 Plenum Protection (Continued) For a plenum, either single or'V"bank, with a linear extension HORIZONTAL PROTECTION OPTION 2 . longer than 10 ft(3.0 m),each bank may be protected using one - . IN nozzle every 10 ft (3.0 m) or less depending on the overall 1W NO771 E-'N.r BANK PROTECTION length of the plenum. See Figure 4-12. The nozzles may point One 1W nozzle will protect 6 linear feet (1.8 m) of NV'" bank in the opposite directions as long as the entire plenum area is plenum.The nozzle must be mounted horizontally,positioned 1r3 . protected, and the 10 ft (3.0 m) limitation is not exceeded. See the filter height down from the top of the fitter. Nozzles can be Figure 4-13.The nozzle positioning shown in Figure 4-14 is not located at 6 ft (1.8 m) spacings on longer plenums. The nozzle an acceptable method of protection because the plenum area must be positioned 0t6 in.(0-152 mm)from the end of the hood to directly under the tee is not within the discharge pattern of either the tip of the nozzle. See Figure 4-10. nozzle. 1W NOZZLE 10 FT(3.0 m)• MAXIMUM 4 1 •[ i':• *i r HF ELItThiG lHRT(OHF) 6 T Me m) m MAXIMUM,10FT(30 my • 4411 13(H) 401 ) MAXIMUM MAXIMUM NN, \\/ ....- 4 FT I •I .."< , ,)' (1.2 rri) ' •0/01101%timw MAXIMUM q FT 19.1 m) 1 / / FIGURE 4-12 cow, iliktri ii- 10 FT(30 m)..,r MAXIMUM FIGURE 4-10 C440.524 , 1 0 Fr(Um) TWO 1N NOZZLES-'V'BANK PROTECTION MAXIMUM *Two 1N nozzles will protect 10 linear feet(3.0 m) by 4 ft (1.2 m) wide of "lr bank plenum. The nozzles must be mounted in the ' MAXIMUM .plenum, 2 to 4 in. (50 to 101 mm) from the face of the fitter, centered between the fitter height dimension,and aimed down the length. The nozzle must be positioned 0-6 in. (0-381 mm)from the . N. .•ja -- ' end of the hood to the tip of the nozzle.See Figure 4-11. c••• „.•4 .\'' ' FT(9.1 my 1 2-4 IN. ., . •• I •401•41 (50-101 mm) 2-4 IN. :, ,,T .. (50-101 --.4.. 42 FIGURE 4-13 mm) tt: zr COX1217,3 4 FT MAXIMUM(1.2rn)___-•.i 11N. , •r', ' \I a. mI0AxFT1(3 0 rn) / - 11rA ss ;NcciFinEc-i 4\\444 0=01 FIGURE 4.14 COW% FIGURE 4-11 1 • R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-7 i 3 Appliance Protection The following pages detail types of appliance protection. Each r design requires several factors: correct nozzle choice, correct nozzle height above hazard,correct nozzle location and correct aiming point. Fryer-Single Nozzle Protection ri 1. Design requirements for fryers are broken down into two types. A. FRYERS WITHOUT DRIPBOARDS i If the fryer does not include a dripboard, measure the internal depth (horizontal dimension from front to back) 1 f and length of the frypot. 1 B. FRYERS WITH DRIPBOARDS If the fryer includes any dripboard areas, measure both the internal depth (horizontal dimension from front to back)and length of the frypot portion,and then measure the internal depth and length of the overall hazard area including any dripboard areas. • 2. Using Table, "Maximum Cooking Area Dimension-Single Nozzle Fryer Protection,"determine which nozzle is needed to protect the fryer based on the maximum dimensions listed. A. If the fryer does not include a dripboard, use the maximum dimensions listed in the first column of the table to select the correct nozzle. B. If the fryer includes any dripboard areas, use both the maximum frypot dimensions in the first column of the table, and the maximum overall dimensions in the second column of the table to select the correct nozzle. None of the maximum dimensions in either column may be exceeded. 3. If either the maximum frypot or the overall sizes are exceeded,an additional nozzle(s)will be required. Refer to the multiple nozzle requirements. Example: A fryer with a dripboard. The inside of the frypot without the dripboard measures 18 in, in depth x 18 in. in length (457 mm x 457 mm) and the inside of the overall area includ- ing the dripboard measures 18 in. in depth x 24 in, in length (457 mm x 610 mm). From the Table "Maximum Cooking Area Dimension - Single Nozzle Fryer Protection, either the 3N or the 290 nozzle should be selected to protect the fryer, depend- ing on the maximum nozzle height above the fryer and the positioning requirements allowed. Refer to appropriate Figures. 1 I 1 . . , , 1 - . 1 SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-8 REV. 11 2014-SEP-01 Fryer-Single Nozzle Protection (Continued) Maximum Area Dimensions-Single Nozzle Fryer Protection Max. Size Max. Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location Full or Split Vat Full or Split Vat 230 27 in.to 47 in. See Figure 14 in.x 15 in. 14 in.x 21 in. (686 mm to 1193 mm) 4-15 and 4-16 ►(355 mm x 381 mm) (355 mm x 533 mm) Full or Split Vat Full or Split Vat 245 20 in.to 27 in. See Figure 14 in.x 15 in. 14 in.x 21 in. (508 mm to 685 mm) 4-15 and 4-16 ►(355 mm x 381 mm) (355 mm x 533 mm) Full or Split Vat Full or Split Vat 290 13 in.to 16 in. See Figure 4-17 14 in.x 15 in. 14 in.x 21 in. ►(355 mm x 381 mm) (355 mm x 533 mm) ( mm to 406 mm) Full or Split Vat Full or Split Vat 290 16 in.to 27 in. See Figure 4-17 141/2in, x14in. 141/2 in.x261/2in. ►(368mmx355mm) (368 mm x 673 mm) (406mmto685mm) I I I '' i Ji/ i II 11 1 ii i il 1 i1 1 1 I II i iii1 11 I 1 i tii TOP OF FRYER I II / I 3 11 I 1 1ITaP OF FRYER3 II I 1 4 lilli 0 04 OP. .0.° alp i 0 i 0 111111.1141).1 I I I 0 0./1011,.. I I I II% ' i ' ' et r- FRYER WITHOUT DRIPBOARD FRYER WITH DRIPSOARD FRYER WITHOUT DRlPBOARD FRYER WITH DRIPSOARD NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIME I EH OF COOKING SPLIT VAT SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA, NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING FIGURE 4-15 SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. mew FIGURE 4-16 R-102 Restaurant Fire Suppression Manual , SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-9 Fryer-Single Nozzle Protection (Continued) Maximum Area Dimensions-Single Nozzle Fryer Protection (Continued) Max. Size Max. Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location • 14.5 in.x 16.5 in. 14.5 in.x 26.5 in. 290 16 in.to 21 in. See Figure 4-17 s.(368 mm x 419 mm) (368 mm x 673 mm) (406 to 533 mm) 19.5 in.x 19 in. 19.5 in.x 25 3/8 in. 290 13 in.to 16 in. See Figure 4-17 •(495 mm x 4-82 mm) (495 mm x 644 mm) (330 to 406 mm) 19.5 in.x 19 in. 19.5 in,x 25 3/8 in. 3N ' See Figure 4-18 See Figure 4-18 •(495 mm x 482 mm) (495 mm x 644 mm) 18 in.x 18 in. 18 in.x 27 3/4 in. 3N 25 in.to 35 in. See Figure 4-19 •(457 mm x 457 mm) (457 mm x 704 mm) (635 mm to 889 mm) ..--...... 'N.-. ......_ i<., '"-' -->1 14•-• _ <8 , -- 1 .s. ' i t t 7. I 1 I 1 1 I 1 I 1i 1 1 1 1 ii 10 1 i 1 i I I 1 I i %if --..411111111110d111:1111111.1111P'..., i I 1 11 111 TOP OF FRYER I i , I i I I I 4111111.1fOP' , ' I 1 s I 1 1 ..... -) - i -400111114111>..., FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD %Al. .. , ......, 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD AREA.3 IN. R IGHT.TO•LEFT .4111 coax* mom (74 mm)FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND t CENTERLINE I IN (25 Trim)FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD AND AIMED AT THE MIDPOINT OF THE COOKING AREA. NOTE: 3N NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE FIGURE 4-17 AREA WITHIN THE FRONT HALF OF THE FRY POT AND AIMED AT THE CENTER COMM FIGURE 4-19 34 IN.(863 mm)MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND .„_:ENTER OF HAZARD AREA in.(54 ,... ,....1.---- irtl-,:--- -4,)-_7,.•).---_-_,; . •:.--", ii ..i/...-- 3 mm) .- , -.....,. I „...- i MINIMUM rt"•- 1 ..., .... 1 I vEaricAt. jo001.1., 1 Nriri*iTF 1.407440"i .; • FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. , FIGURE 4-18 =Mr SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-10 REV. 11 2014-SEP-01 Fryer-Multiple Nozzle Protection A. If the module considered does not include any portion of the dripboard,use only the maximum frypot area and Design Requirements: maximum dimension listed in the first column of the Fryers exceeding the coverage of a single nozzle can be divided table to select the correct nozzle. into modules. Each module must not exceed the maximum B. If the module considered includes any dripboard areas. area allowed for a single nozzle. However, when utilizing multi- use both the maximum frypot area and dimension pie nozzle protection, the longest side allowed for a fryer with listed in the first column of the table, and the maximum dripboard can be used, regardless of whether the fryer has a overall area and dimensions listed in the second dripboard or not, column of the table to select the correct nozzle. The maximum size fryer that can be modularized is 884 in.2 3. None of the maximum dimensions in either column may be 1.(55742 mm2). exceeded. If either the maximum frypot or the overall sizes 1. Design requirements for multiple nozzle fryers are broken are exceeded,the area divided into modules will need to be down into two types: redefined with the possibility of an additional nozzle. A. FRYERS WITHOUT DRIPBOARD(S) If the fryer does not Include a dripboard, measure the Options For Modularizing Fryers internal depth(horizontal dimension from front to back) The following Figure 4-20 shows approved methods of divid- end length of the frypot. Then, multiply the depth and ing (modularizing) fryers so that each section can be properly length to obtain the area of the frypot in square inches. protected.Example: A fryer with a dripboard. The Inside vat without the dripboard measures 18 In, in depth x 30 in. in length B. FRYERS WITH DRIPBOARD(S) (457 mm x 762 mm) and the inside of the overall vat includ- If the fryer includes any dripboard areas, measure ing the clapboard measures 24 In, in depth x 30 in. in length both the internal depth and length of the frypot portion, (610 mm x 762 mm). Because the fryer is 30 in. (762 mm) in and then measure the internal depth and length of the length, it exceeds the coverage of a single nozzle. overall hazard area including any dripboard areas. Dividing the length in half, each module now has an overall Determine the area of both the frypot and the area of vat dimension of 24 in. In depth x 15 in, in length (610 mm x the overall vat by multiplying corresponding depth and 381 mm). From the Table, 'Maximum Cooking Area Dimension length dimensions. - Multiple Nozzle Fryer Protection,• either the 3N or the 290 2. Divide the frypot or overall vat into modules, each of which nozzle should be selected to protect each fryer module,depend- can be protected by a single nozzle,based on the maximum ing on the maximum nozzle height above the fryer and the dimension and area coverage of the nozzle as specified positioning requirements allowed. Refer to appropriate Figures, in Table. 'Maximum Cooking Area Dimension - Multiple 4-15 through 4-19. Nozzle Protection." See additional examples in Appendix Section. AREA OF EACH FRY POT MODULE CANNOT EXCEED 324 IN'(20903 fnm'') EACH MODULAR AREA.INCLUDING DRIPBOARD, MUST NOT EXCEED 487 IN (32064 rnm') AREA OF EACH FRY POT MODULE mow CANNOT EXCEED r" 324 IN.2 20903 nun2) MIDPOINT I MIDPOINT WINN 14••••• 4. AREA OF THIS MODULE(FRY POT PLUS DRIP —BOARD)CANNOT EXCEED 497 IN.2 032295 DRIP BOARD I DRIP BOARD DRIP BOARD (32064 mar') EXAMPLE ONLY FRYER WITHOUT DRIPBOARC mos °XV EXAMPLE ONLY EXAMPLE ONLY FRYER 'TN DRIPBOARD FRYER WITH DRIPBOARD FIGURE 4-20 R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-11 Fryer-Multiple Nozzle Protection (Continued) Maximum Area Dimension-Multiple Nozzle Fryer Protection Max. Size Module Max. Size Module Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location Full or Split Vat Full or Split Vat 21 in.x 210 in.2 21 in.x 294 in.2 230 27 in.to 47 in, See Figure 4-21 (533 mm x 0.14 m2) (533 mm x 0.19 m2) (686 mm to 1194 mm) Full or Split Vat Full or Split Vat 21 in.x 210 in.2 21 in.x 294 in.2 245 20 in.to 27 in. See Figure 4-21 (533 mm x 0.14 m2) (533 mm x 0.19 m2) (508 mm to 686 mm) Full or Split Vat Full or Split Vat 21 in.x 210 in.2 21 in.x 294 in.2 290 13 in.to 16 in. See Figure 4-22 (533 mm x 0.14 m2) (533 mm x 0.19 m2) (330 mm to 406 mm) 25 3/8 x 370.5 in2 25 3/8 x 495 in2 290 13 in,to 16 in. See Figure 4-22 (644 mm x 0.24 m2) (644 mm x 0.32 m2) (330 mm to 406 mm) Full or Split Vat Full or Split Vat 26 1/2 in.x 203 in.2 26 1/2 in.x 384 1/4 in.2 290 16 in.to 27 in. See Figure 4-22 (673 mm x 0,13 m2) (673 mm x 0.25 m2) (406 mm to 686 mm) 25 3/8 x 370.5 in2 25 3/8 x 495 in2 3N See Figure 4-23 See Figure 4-23 (644 mm x 0.24 m2) (644 mm x 0.32 m2) 27 3/4 x 324 in.2 27 3/4 x 497 in2 3N 25 in. to 35 in. See Figure 4-24 (704 mm x 0.21 m2) (704 mm x 0.32 m2) (635 mm to 889 mm) ...... co:,,,, 000,32,3 FRY(:ER...4.wrrpi;r777:::::,1080,1,,3,40ARI),srNDAN.14Az41:2::;metsrweiEINFITIGALH:):::mtts)3:!:NIrnmMNUOFRMI;AG..w:O.Ilirrtir_dr,\ILi.ii...0.,":imorjwipsoimmiHwAARImoposma29::: ..•-••••-•, ........._ ...."-^, 7 ,„,:-- ..,.... L., . -..-'1‹:' 'T I -11<'.:,//,'": 1' ..,'''- 1 / , r '''T- ' s. , . ,,,,71...--• -":. ' I _ AND CENTER OF ....=7,7_,...,_ ... '-; II ! : N, I T '). -1 • . i i . 1 ,,4„.. i — 1 1 I 1 , I i i ! fillip 1 i 1 i I __I•iFil.iitligOpipp. 1 N0E ' : olip 1 441t,'34<°11Ip .44°W11101.- 1 '-''----1.411 •, .°' ,,,1 414,11111°- 0%10,..0-p-1-, ''- ....) 3N NOZZLETIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE PERIMETER FRYER WITHOUT DRIPBOARD FRYER WITH ORiPSOARD OF THE MODULAR IT IS PROTECTING AND AIMED AT THE MIDPOINT of THAT RESPECTIVE MODULE AREA. POSITION NOZZLE TIP ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE MODULE IT IS PROTECTING AND AIM AT THE MIDPOINT OF THAT MODULAR AREA. FIGURE 4-23 FIGURE 4-21 `-,..,„.' ';') (DIAGONAL --" ...,,, 1 I AIM POINT(DIAGONAL I I I ' CENTER OF I I I I: I 1 MODULE ......"''N, ..ri- '...., CENTER OF MODULE i i 1 1 , ' 1-.... ...." 1 ...' "" 1 --. --- COOKING AREA) i I i t 1 COOKING I I 1 I; AREA) 1 I II , 1 1 ' I I 1 , ; 1 i i I 1' I ;. g,1 %daft. I , i RIGHT-TO-LEFT I I v i 01111 I TO-LEFT .... 11114111i111711C1:111111:1:111.11. fthii .,,44f°11 . .-"IIIIIIIIIIII com iiiiiiiiir'-^ 411111:14- CENTERLINE <4000 1184.- ..80 likt -..t. ' 101,a CENTER- ' livd/fts. LINE "4111/P„:41/bp. i co2303 FRYER WrIliOUT OFIIPBOARD FRYER WITH()SIMARD PRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE RESPECTIVE MODULAR THE 3N NOZZLE TIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE AREA.3 IN (78 mm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE PERIMETER AND FORWARD OF THE RIGHT-TO-LEFT GENTERUNE OF THE COOKING MODULE AND.1 IN.(25 mm)FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF AREA THE AIMING POINT OF THE NOT,LF MUST BE AT THE DIAGONAL CENTER OF THE MODULE AND AIMED AT THE MIDPOINT OF THE MODULE. THE MODULAR COOKING AREA. FIGURE 4-22 FIGURE 4-24 ,__, SECTION 4—SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-12 REV. 11 2014-SEP-01 Multiple Nozzle Fryer Protection —Tilt Skillet/Braising Pan Protection for tilt skillets or braising pans Is to be based upon the coverage limitations provided for deep fat fryer protection. Refer COVER MUST NOT ..--� I to Section IV.DESIGN,startin on Page 4-10,for maximum fryer INTERFERE WITH EDGE ;/1 1 g rY OF DISCHARGE PATTERN nozzle coverages and maximum fryer nozzle height limitations. / Although the maximum 864 in.2 (55741 mm2) total surface ;/ cooking area requirement applies to fryer protection, it does not „/ / FOR MINIMUM apply to tilt skillets or braising pans. /' / NOZZLE maximum HEIGHTS,REFER Each tilt skillet/braising pan protected module must not exceed / TO FRYER the fryer limitations for "MAXIMUM SIZE MODULE OVERALL / N Ram WITH DRIPBOARD" coverage per nozzle as described in Table PARAMETRs on Page 4-11. , Tilt skillets and braising pans generally utilize a hinged cover. 1 Fryer protection nozzles are to be placed toward the front of the appliance to minimize the potential for the tilt skillet or braising pan cover to interfere with the nozzle discharge. See Figures 4-25 and 4-26. FRYER NOT7 F USED FOR TILT SKILLET OR BRAISING PAN PROTECTION MUST BE POSITIONED NEAR THE FRONT EDGE OF THE PAN AND AIMED AT THE FRONT TO BACK COVER MUST NOT INTERFERE CENTERLINE OF THE PAN.THE DISCHARGE FROM THE NOZZLE(S1 MUST COMPLETELY WITH N0771 F DISCHARGE CLEAR THE PAN COVER WITH AN UNOBSTRUCTED VIEW TO THE BACK OF THE PAN. 0 FIGURE 4-26 0 / 4411Q.rfrii01110#.1146. 10i THE N0771 F IS TO BE PLACED TOWARD THE FRONT OF THE APPUANCE TO MINIMIZE THE POTENTIAL FOR THE SKIUET OR BRAISING PAN COVER TO INTERFERE WITH THE NOZZLE DISCHARGE_ FIGURE 4-25 r 1 . /4 R-702 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 / - 2014-SEP-01 REV. 11 PAGE 4-13 1 ..._. 0 c. Range Protection The R-102 system uses five different nozzles for the protection of ranges. Two of the design options require a one-flow nozzle 4. it 0 ir•o;n141 Ify444 I and three of the design options require two-flow nozzles. NOTICE 41 111111111111k MAX03321211MImNiji4im.) I A 13 in. (330 mm) diameter wok pan is the it4oN zaz......4( largest wok size that can be protected on ranges. AIMING POINT When protecting hot top ranges, the entire I cooking surface must be protected. 10 IN. (2ZImmMUL A\ Range Protection 'IN 0-Flow)Nozzle—High Proximity C0554.1 Application FIGURE 4-28 No Obstructions Single and multiple burner ranges can be protected using a 1N w nozzle. The nozzle is stamped with 1N, indicating that this is a one-flow nozzle and must be counted as one flow number. When using this nozzle for range protection, the maximum length of the burner grates being protected with a single nozzle must not exceed 32 in. (812 mm)and the maximum area of the burner grates must not exceed 384 in.2(24774 mm2)per nozzle. When protecting a range, the 1N nozzle must be located a maximum of 10 in. (254 mm) from each burner grate centerline and must be aimed at the center of the cooking surface. See Figures 4-27 and 4-28. \ / i WIN. N\-;14-741,7 1-4\--- (1018mm) 30 IN. \\,,t\ I // (7052 nun) Az.: I N i 1 11 COSS39 FIGURE 4-27 SECTION 4—SYSTEM DESIGN R-702 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-14 REV. 11 2014-SEP-01 . — Range Protection 245(2-Flow)Nozzle—High Proximity Application COOKING No Obstructions 4—AREA 40 in, to 50 in. (1016 mm to 1270 mm) above the cooking surface. This high proximity application uses the 245 nozzle. 1><A._ :;< COOKING The nozzle is stamped with 245 indicating this is a two-flow 248 NO771 g TIP " . " AREA nozzle and must be counted as two flow numbers. LOCATION CENTER OF COOKING SURFACE OR One 245 nozzle will protect a maximum cooking area of 672 in.2 3/8 IN.(288 rnm) (43354 mm2) with a maximum longest dimension of 28 in. mAximum FROM CENTERLINE OF NOZZLE (711 mm). TO CENTER OF ANY BURNER GRATE When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures 4-29 and 4-30. COOKING AREA 245 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE 4r1—.1 245 NOVI F TIP COOKING AREA LOCATION CENTER OFiw+ COOKING SURFACE OR 4; 50 IN 1-1 3,08 IN.(288 mm) (1270 mm) MAXIMUM FROM MAXIMUM CENTERLINE OF NOZZLE HEIGHT TO CENTER OF AN' wzree OF 245 BURNER GRATE NOZZLE FIGURE 4.30 TIP 40 IN. (1016 rnm) MINIMUM I HEIGHT OF 245 NOZZLE I TIP I I misimmismoommx 0000 FIGURE 4-29 NOTICE Four burner grates shown in Figure 4-30. For single or double burner grates, locate nozzle at center of cooking surface or 11 3/8 in. (288 mm) maximum from nozzle centerline to center of any burner grate. R-102 Restaurant Fire Suppression Manual SECTION 4 -SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-15 .__ Range Protection 260(2-Flow) Nozzle-Medium Proximity COOKING Application AREA No Obstructions 30 in.to 40 in.(762 mm to 1016 mm)above the cooking surface. 11...171h1912 b'r The medium proximity application uses the 260 nozzle. ilir lig Or N I , COOKiNG ' The nozzle is stamped with 260 indicating this is a two-flow AREA nozzle and must be counted as two flow numbers. 260 NOzzLE TIP COIF Ir I LOCATION CENTER r or ii, One 260 nozzle will protect a cooking area of 768 in.2 OF COOKING (49548 mm2)with a maximum dimension of 32 in. (812 mm). SURFACE OR When using this nozzle for range protection, the nozzle must 10 IN {254 mm) MAXIMUM FROM be pointed vertically down and positioned as shown in Figures CENTERUNE OF NO7r F TO 4-31 and 4-32. CENTER OF ANY , COOKING BURNER GRATE AREA 260 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE r1111111111111„ ,. 1 260 NOZZLE TIP LCX ATION CENTER Ca° Il (o COOKING COOKING ill .-- --11 i SURFACE 4 kill km+ OR AREA MAXIMUM CENTERLINE I HEIGHT OF NOZ7I F TO OF 260 CENTER OF ANY I BURNER GRATE I I NO77I F TIP FIGURE 4-32 __ 30 IN (782 mm)I MINIMUM I HEIGHT NOTICE I OF 260 Four burner grates shown in Figure 4-32. For I TIP 1 I I single or double burner grates, locate nozzle at center of cooking surface. iiii "...1111-171-1E.. Mit comae 0 0 0 0 4 FIGURE 4-31 SECTION 4—SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-16 REV. 11 2014-SEP-01 Range Protection 1N (1-Flow)Nozzle—Low Proximity Range Protection Two 290(2-Flow) Nozzles—Low Application Proximity Application 15 in.to 20 in. (381 mm to 508 m)above the cooking surface. 15 in.to 20 in. (381 mm to 508 mm)above the cooking surface. The low proximity 1-flow nozzle application for the protection of The low proximity 2-flow application requires the use of two 290 ranges requires the 1N nozzle. nozzles. ► The nozzle is stamped with 1N indicating that it is a one-flow ► Both nozzles are stamped with 290 indicating they are two flow nozzle and must be counted as one flow number, nozzles and must be counted together for a total of four flow When using the 1N nozzle for low proximity range protection numbers. with or without obstruction, the maximum length of the burner Two 290 nozzles will protect a cooking area of 1008 in.2 grates being protected must not be exceed 24 in. (609 mm) (65032 mm2) with a maximum dimension of 36 in. (914 mm). length,aimed along a centerline to a point 20 in. (508 mm)from When using two of these nozzles for low proximity range protec- the end of the length, protecting a maximum width of 18 in. (457 tion, the nozzles must be positioned along the cooking surface mm). perimeter to 1.5 in. (38 mm) inside the perimeter, and aimed at When protecting a range, the 1N nozzle must be located a a 45° angle along the longitudinal centerline of the range, See maximum of 9 in. (228 mm) from each burner grate centerline Figures 4-35 and 4.36. and must be positioned above the edge of the hazard area to be290 NOME TIP protected. '°— LOCATION 0-t.5 IN. -'"'' The 1N nozzle tipmust be IN-se"'E positioned at or below the obstruc- IN FROM EDGE OF tion, ifpresent. Theprotected area 45' COOKING SURFACE 45' begins at the point straight down from the nozzle tip.The nozzle can be placed at the side I } of the range aimed either left or right, or can be placed in the I I ) i I 1 front or back of the range.See Figures 4-33 and 4-34 for nozzle 15 IN TO20IN. 1 I l 15 IN TO 20 IN. location details. Palto508 ) 1 ! MAXIM I 1381 508 mm; UM I I MAXIMUM i II I I I s,'\. 1 © 00 000 Ile \ FIGURE 4-35 \ 15-20 IN. \ AIM COOKING LONGITUDINAL (381-508 rnm) \ 3 $,01r AREA —' CENTERLINE 20W.\ I—(KS mm) \. 1 RI ff�// t0 0 0 0 1 , is.E JOKING I i Ili ,`; - AREA FIGURE 4-33 [0.—Pail MO I'4 r�. ■ PROTECTED AREA 290 NOZZLE TIP y -+- LOCATION CENTER OF COOKING SURFACE i i 290 NOZZLE TIP LOCATION 2 2 IN.(50 mm) • 91N. ; 0-1.5 IN.(38 mm)IN FROM EDGE C22amin) OF COOKING SURFACE i 18 IN (457 mm) Y ' 1 [t AREA COOKING OWES 1 J Is it ar COOKING I } A)M POINT ! AREA 20 IN. - -Caa—rt 1 1.`--(508 mm)--. : r I I. (9mrm) FIGURE 4-34 290 NOZZLE TIP .4- - i -LOCATION CENTER OF COOKING SURFACE 290 NO7 1 F TIP LOCATION s 2 IN.(50 mm) 0-1.5 IN.(38 mm)IN FROM EDGE OF COOKING SURFACE FIGURE 4-36 R-702 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-17 Range Protection (With or Without Back Shelf/Obstruction) Range Protection 260(2-Flow) Nozzle(With or Without • When this type of hazard is equipped with a back shelf or other Back Shelf/Obstruction) similarly sized obstruction located above the range top, two Single and multiple burner ranges can be protected using a 260 protection options are available: One requires a 1F nozzle and 0.•nozzle. The nozzle is stamped with 260 indicating that it is a the other option requires a 260 nozzle. two-flow nozzle and must be counted as two flow numbers. When using the 260 nozzle for range protection with or without Range Protection 1F(1-Flow) Nozzle(With or Without Back back shelf or other similarly sized obstruction, the maximum Shelf/Obstruction) length of burner grates being protected must not exceed 32 in. Single and multiple burner ranges can be protected using a (812 mm) and the maximum area of the burner grates must 1F nozzle. The nozzle is stamped with 1F indicating that It is a not exceed 384 in.2 (24774 mm2). Nozzle must be located on one-flow nozzle and must be counted as one flow number. the front edge of the burner grates and aimed at a point 10 in. When using the 1F nozzle for range protection with or without back (254 mm)from the back edge of the burner grates.Nozzle must shelf or other similarly sized obstruction, the maximum length of be mounted 30 to 40 in. (762 to 1016 mm) above the hazard the burner grates being protected must not exceed 28 in. (711 surface. See Figure 4-38. mm)and the maximum area of the burner grates must not exceed 336 in.2(21677 mm2).See Figure 4-37 for nozzle location details. 26°NOZZLE SHELF OR OTHER SIMILARLY SIZED OBSTRUCTION CAN OVERHANG BURNERS) 1F NOZZLE BY A MAXIMUm OF IN.(279 mm) SHELF OR OTHER SIMILARLY SIZED OBSTRUCTION CAN OVERHANG BURNER(S) BY A MAXIMUM OF 11 IN.(279 mm) 18 IN. 30-40 IN. (457 Mm) MINIMUM 20 IN. (762-1018 mm) AIM (508 rrtm1 40-48 IN POINT MINIMUM (1018 1219 mm) 10 IN (24 mm) FROM BACK 14 IN, OF BURNER (355 mm) GRATES MAXIMUM 12 IN 14 IN. (304 mm) (355 mm) FIGURE 4-38 FRONT TO REAR MAXIMUM MAXIMUM CENTERUNE 00O233a IF NOZZLE LOCATED OVER FRONT EDGE OF BURNER GRATE AND ORIENTED SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER GRATE FRONT TO REAR CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE FIGURE 4-37 WC214 ••• • SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-18 REV. 11 2014-SEP-01 Griddle Protection 1N (1-Flow) Nozzle-High Proximity Griddle Protection 290(2-Flow)Nozzle-High Proximity Application Application The R-102 system uses four different nozzles for the protection Option 1 -Nozzle Center Located of griddles.One of the applications requires a 1-flow nozzle and 30 in,to 50 in, (762 mm to 1270 mm)above the cooking surface. three of the applications require a 2-flow nozzle. This high proximity application uses the 290 nozzle. High Proximity Application: 35 in. to 40 in. (889 to 1016 mm) above the cooking surface. 'The nozzle is stamped with 290 indicating this is a 2-flow nozzle and must be counted as two flow numbers. This high proximity application uses the 1N nozzle. One 290 nozzle will protect a maximum cooking area of 720 in.2 *The nozzle is stamped with 1N indicating this is a one-flow (46451 mm2)with a maximum dimension of 30 in. (762 mm). nozzle and must be counted as one flow number. When using this nozzle for high proximity applications, the One 1N nozzle will protect a maximum cooking area of 1080 in.2 nozzle must be positioned within 1 in. (25 mm) of the center (69677 mm2)with the maximum longest side of 36 in.(914 mm), of the cooking surface and pointed vertically down. See Figure When using this nozzle for griddle protection,the nozzle must be 4-41 and 4-42. positioned along the cooking surface perimeter to a maximum of CENTER LINE OF GRIDDLE 2 in. (50 mm)inside the perimeter,and aimed to the midpoint of SURFACE t 1 IN.(25 mm)IN ANY DIRECTION the cooking surface. See Figure 4-39 and 4-40. i I I NOTICE I 50 IN I ono mm) When using this type of griddle protection, I MAXIMUM only five flow numbers are allowed on a 1.5 i Cs HEIGHT OF 290 I gal (5.7 L) system and only 11 flow numbers t NOZZLE TIP I are allowed on a 3 gal (11.4 L.)system. I 30 IN. 1 (752 mm) MINIMUM I HEGHT COOKING SURFACE I 1 r 1 1 1 _.1.1.11. ......„.OF 290 NOZZLE TIP / 7 --, FIGURE 4-41 i 00024. IN NOZZLE LOCATED ALONG COOKING ANY SIDE OF GRIDDLE SURFACE WITHIN SURFACE 0-2 IN.(0-50 mm)OF COOKING EDGE COOKING AREA SURFACE EDGE.NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING NOZZLE 1!N.(25 mm) SURFACE FIGURE 4-39 LOCATION MAXIMUM 11111111111 Ill I I NOZZLE LOCATION I I 0-2 IN.f0-50 mm) I / INSIDE PERIMETER I 40 IN. I --a- 40- OF COOKING SURFACE I I (1016 rim) /A-7 1 / I 1 MAXIMUM la r .,F(341),r° / I HEIGHT I , I / 1 1 t OF 1N NOZZLE TIP I Ili.(25 rrn) 1 / / I I 35 IN.(889 mm) MAXIMUM I / 1 I MINIMUM / 1 I HEIGHT EDGE 1 1 OF 1N 14072I F TIP CENTER OF GRIDDLE SURFACE OR A COOKING I I .1 1 MAXIMUM DIMENSION OF 20.8 IN. SURFACE I i' (523 mm)FROM NOZZLE CENTERLINE TO FURTHEST CORNER OF GRIDDLE FIGURE 4-42 FIGURE 4-40 0=4 .. „,. ., ..:.:,., , , „,„ .„ R-1 02 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-19 Griddle Protection 260(2-Flow)Nozzle-High Proximity Griddle Protection 290 (2-Flow)Nozzle-Medium Proximity Application Application Option 2-Nozzle Perimeter Located Option 2a-Nozzle Perimeter Located (Continued) 30 in.to 50 in.(762 mm to 1270 mm)above the cooking surface. 20 in.to 30 in. (508 mm to 782 mm)above the cooking surface. This high proximity application uses the 260 nozzle. The medium proximity application uses the 290 nozzle. P.The nozzle is stamped with 260 indicating this is a two-flow ►The nozzle is stamped with 290 indicating this is a two-flow nozzle and must be counted as two flow numbers. nozzle and must be counted as two flow numbers. One 260 nozzle will protect a maximum cooking area of 1440 in.2 One 290 nozzle will protect a maximum cooking area of 1440 in.2 (92903 mm2)with a maximum dimension of 48 in. (1219 mm). (92903 mm2) with a maximum dimension of 48 in. (1219 mm). When using this nozzle for griddle protection, the nozzle must When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to 2 in. be positioned along the perimeter to 2 in. (50 mm) inside (50 mm)inside perimeter,and aimed at the center of the cooking perimeter,�5 ando da�end at the center of the cooking surface. See surface. See Figure 4 13 and 4-44. Figure COOKING AREA 1 I NOZZLE LOCATION 1 t In/ - 1 0-2 IN.(0-50mm) I INSIDE PERIMETER I 50 IN, —► L. OF COOKING SURFACE I I ((1MUM I SURFACE ` I 0 mm) HEIGHT OF250fNOZZLETIPACROEOA MG i //11!-f ) 190 IN.(762 mm)/ // 1 IMINIMUM1 ; { / I I HEIGHT EDGE ( I OF280 ��--J OF--� I ) TTP COOKING I I , NOZZLE I SURFACE I I I °037A3 290 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0—2 IN.(0—50 mm)OF COOKING SURFACE EDGE NOZZLE MUST BE AIMED AT CENTER OF FIGURE 4-43 COOKING SURFACE. FIGURE 4-45 a COOKING AREA ► �. 1 I NOZZLE LOCATION m ) 4 1 I 0—2 IN.(0—57 m) rI INSIDE PERIMETER I30IN COOOKING S KI -HOF COOKING SURFACE 1 1 (762 mm) MAXIMUM �!/ COOKINGJ IGHT OHF00TAREA . I NOZZLE TIP AIM1 I i 20IN.(508mm) I / IMINIMUM L-_.---.�_..�. / I HEIGHT OF 290 i I / i I NNor,P TIP 1i I 280 140771 F LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE EDGE OF WITHIN 0—2 IN,i0—S1 ITon)OF COOKING COOKING SURFACE EDGE.NOZZLE CORKAGE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. FIGURE 4-44 006NI FIGURE 4.46 SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-20 REV. 11 2014-SEP-01 Griddle Protection 2120(2-Flow) Nozzle-Low Proximity Griddle Protection 2W (2-Flow) Nozzle-Low Proximity Application Application Option 2b-Nozzle Perimeter Located (Continued) Option 2c-Nozzle Perimeter Located(Continued) 10 in.to 20 in. (254 mm to 508 mm)above the cooking surface. 10 in.to 20 in. (254 mm to 508 mm)above the cooking surface. The low proximity application uses the 2120 nozzle. The low proximity application uses the 2W nozzle. ir•The nozzle is stamped with 2120 indicating this is a two-flow 'The nozzle is stamped with 2W indicating this is a two-flow nozzle arid must be counted as two flow numbers. nozzle and must be counted as two flow numbers. One 2120 nozzle will protect a maximum cooking area of 1440 One 2W nozzle will protect a maximum cooking area of low in.2 in.2(92903 mm2)with a maximum dimension of 48 in.(1219 mm). (69677 mm2)with a maximum dimension of 36 in. (914 mm). When using this nozzle for griddle protection, the nozzle must When using this nozzle for griddle protection,the nozzle must be be positioned along the perimeter to 2 in.(50 mm) inside perim- *positioned 0-10 in.(0-254 mm)forward or behind the right to left eter,and aimed at the center of the cooking surface.See Figure i 1 centerline of the hazard area. See the diagram below for nozzle 4-47 and 4-48. I.location and aiming. I NOZZLE LOCATION I 4------7 OVERHEAD VIEW i r)-2 IN.(0-51 mm) I INSIDE PERIMETER I 20 IN. • --10-1 to- OF COCKING SURFACE I (508 rrtm) *iN.014 rnm)MAX r I I ! MAXIMUM I ' HEIGHT I I OF 2120 /1"1-1-b NOZZLE TIP , I I ' 2W *TA g AIM poKr / 1 I ION.(254 nun) 4 rozi)N47 6s urtra;&REART OF / / I ,,,,,,,,„.. 1 ,.10 IN. , LINE WHEN 2W NOZZLE IS HEIGHT giimw rnFIA,FRAI ; POSITIONED AT OR TO THE 1 1 OF 2120 REAR OF CENTER LINE NOZZLE TIP X IN I I 1 i 2W NOZZLE AIM POINT I MAX. t;-ION. 1 '-OF tog07'4G )Mr° I CCON3 8°E N'4 4 rT ER Z ti 1 in F 1Za t I CENTER LINE WREN 2W I - NOZZLE IS POSITK)NED AT EDGE OF q. I OR FORWARD OF COOKING SURFACE CENTER UNE COOKING SURFACE I ca.,. FIGURE 4-47 i 0 i. ore2,- AIM POINT 9 IN.(228 mm ) FROM EITHER SIDE OF COOKING AREA COOKING SURFACE FIGURE 4-49 FRONT VIEW "Dr---1———————---, : i 7 CENTEFI OF I 1 COOKING SURFACE 1 ; ""-- ,' 0-3 IN.(76 mrn; I / i I NOTE:A 2W W1771 F CAN PROTECT A 1 + / COOKING GRIDDLE WITH A MAXIMUM COOKING SURFACE OF 30 IN X 36 IN,DV 7(on X I / 1 AREA 914 rnrn),AT A HEIGHT OF 10-20 IN.(254 I i -508 mrn). 1,4— AIM POINT THE 2W NOZZLE CAN BE POSMONE0 (509 I'm) AForw0MUM0SIFI s 1 Cif,,,,,,, ,c:4(1,11& • MAX SURFACE CENTER LINE AND A • MAXIMUM OF 3 IN.(76 mrn)AWAY 10 IN. FPOM EITHER SIDE OF THE COOKING 0254 mrn) SURFACE,AIMED IN 9 IN.(228 mrn)TO 2120 NOZZLE LOCATED ALONG COOKING SURFACE EDGE MIN. POTINT 3RAAO0F•76rriEnntonWGARD ANY SIDE OF GRIDDLE SURFACE SURFACE CENTER LINE WITHIN 0-2 IN.(0-51 mm)OF COOKING SURFACE EDGE NO2Z-E , ! MUST BE AIMED AT CENTER OF COOKING SURFACE. I ; FIGURE 4-48 coxo, AiM POINT 9 IN. SIDE OF COOKING SURFACE N 0001K FIGURE 4-50 R-102 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-21 .,... Griddle Protection 1W(1-Flow) Nozzle—Low Proximity Chain Broiler Protection The following listed protection guidelines can be applied to any Application 15 in.to 20 in.(381 mm to 508 aim)above the cooking surface. manufacturer's chain broilers, if the chain broiler roiler mcoenevtserttehres The low proximity 1-flow nozzle application for the protection of specified parameters.Chain broilers aiming catalytic griddles protected from overhead using model specific protec- tion requires the 1W nozzle. tion identified in the 'Specific Application by Model" section in The nozzle is stamped with 1W indicating that this is a one-flow System Design. Or, they can be protected with standard 1N nozzle and must be counted as one flow number. nozzle horizontal chain broiler protection with the nozzles posi- When using the 1W nozzle for low proximity griddle protection toned at either end of the chain broiler openings. Refer to the with our without obstruction,the maximum length of the cooking "Horizontal Chain Broiler Protection"section for specific design surface to be protected must not exceed 26 in. (660 mm).The information. nozzle must be centered at one end of the maximum 26 in. (660 mm)length,aimed along a centerline to a point 20 in.(508 Horizontal Chain Broiler Protection mm)from the end of the length, protecting a maximum width of The R-102 system can use two 1 N nozzles for horizontal chain i 20.5 in. (520 mm). ii.broiler protection. The nozzle s stamped 1N, indicating that The 1W nozzle tip must be positioned at or below the obstwc- this is a one-flow nozzle and must be counted as one flow ton, if present. The protected area begins at the point straight numrr(total of two flow numbers for each chain broiler being down from the nozzle tip.The nozzle can be positioned above probe temed the edge of the nazard area to be protected. See Figure 4-51 Two 1N nozzles are always needed for chain broiler protec- and 4-52. tion when the hazard area to be protected does not meet the Note: If the hazard area exceeds the single nozzle coverage 'Overhead Broiler Protection* requirements. The maximum listed above, additional nozzles will be required,The additional Internal size of the broiler is 43 x 31 in. (1092 mm x 787 mm). nozzle can be positioned in front at high proximity or at the side The nozzles must be positioned at each end of the enclosed at low proximity, cooking chamber 1 to 3 in.(25 mm to 76 mm)above the surface of the chain and a maximum distance of 4 in. (101 mm) away from the broiler opening.The nozzles may be mounted at either __ corner as long as they are at opposite ends of the chain broiler and positioned to discharge diagonally across the top of the ‘,. chain.See Figure 4-53 and 4-54. i ,....., I ,,,-;',;;; * t ' N• --,., , 15IN AN •":''''''W rt (381-EOR Mrn) N.,.. POINT 0 0 0 0 I 111111110.. 00.,' -- telli°''' FIGURE 4-51 tv.442. PROTECTED AREA Ti 111411............. i ,......... 1$08/1110 . NiN/~~0~010"6"*"*. 1-3 IN. (26-76 mrn) wigs riMill PON PO IN Eti T FIGURE 4-53 At 1 os rivn26 IN , 1 r (660 mr„) FIGURE 4-52 -------_ . . , SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-22 REV. 11 2014-SEP-01 Horizontal Chain Broiler Protection(Continued) The nozzles may vary in position as long as they are evenly 7 spaced from the exhaust center and are always 180° opposite of each other. If the opening is not square, the nozzles must be , positioned along the centerline, parallel to the longest side of the opening.See Figure 4-56. :•.::::::: :..-_,:,,•,_.. ...,..,,-S,'•.:,:-/::'-. 4 141.:4111111111111111P -' MAXIMUM INTERNAL 111 1111111b. 1' s'"•••,..-001111111111 BROILER SIZE 43 X 31 IN II (1092 X 757 MIT) ll Atte' IIII FIGURE 4-54 Overhead Chain Broiler Protection The R-102 system can use two 1W nozzles for overhead chain TOP VIEW roPviEW broiler protection. The nozzle is stamped with 1W, indicating that this is a one-flow nozzle and must be counted as one flow FIGURE 4-56 number. CCONL8 Overhead protection is only available for chain broilers with i.Note; The Metal Blow-off Cap must be used when utilizing exhaust opening dimensions that are not less than 60% of the chain broiler protection, internal broiler length and not less than 60% of the internal Example No.1 -Internal broiler size is 24 in.long x 20 in.wide broiler width, to a minimum size of 12 in. x 12 in. (305 mm x (609 mm x 508 mm), with an opening of 16 In, x 16 in. 305 mm). Internal broiler size can not be larger than 32 in. x (406 mm x 406 mm). 34 in. (812 mm x 863 mm). To determine minimum opening size, multiply the internal When overhead protection is used, the nozzles must be length and the internal width by 0.6: centered above the exhaust opening within 4 to 8 in.(101 to 203 mm)of each other and they must be located 10 to 26 in. (254 to Length of opening-24 in.x 0.6=14.4 in. 660 mm) above the top of the broiler surface. See Figure 4-55. (609 mm x 0.6=366 mm) Width of opening-20 in.x 0.6= 12.0 in. -41 4-8 IN.(101.203 min) (508 mm x 0.6=304 mm) The minimum allowable opening for overhead protection !Let l>10-26 IN, would be 14.4 in. x 12.0 in. (365 mm x 304 mm). I ' (25.4-660 mm) This example would be acceptable for overhead protec- tion. 12 IN,(305 run) Example No. 2 - Internal broiler size is 30 in, long x 24 in. wide (762 x 609 mm) with an opening of 22 in. x 12 in, / 12 IN.(305 mrn ,...--_.. ..::"..-__ „, MINIMUM (558 x 304 mm). 1 -: --_,.. MINIMUM To determine minimum opening size, multiply internal length and internal width by 0.6: II N MAXIMUM INTERNAL Length of opening-30 in.x 0.6=18.0 in. BROILER SIZE 32 X 34 IN, (762 mm x 0,6=457 mm) (212 x 863 rnfro Width of opening-24 in.x 0.6= 14.4 in. (609 mm x 0.6=365 mm) FIGURE 4-55 cotae Minimum allowable opening for overhead protection would be 18 in. x 14.4 in. (457 mm x 365 mm), Because this broiler has an opening of 22 in. x 12 in. (558 mm x 304 mm), the 12 in, (304 mrri)width is below the minimum allowable calculated dimension of 14.4 in. (365 mm) and therefore would not be acceptable for overhead protection. --,, Salamander Broiler Protection The R-102 system uses three different nozzle locations for salamander broiler protecton. All of the design options require a one-flow nozzle. R-102 Restaurant Fire Suppression Manual SECTION 4 -SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-23 ,.,. l Salamander Broiler Protection-1N (1-Flow) Nozzle Salamander Broiler Protection-1N (1-Flow)Nozzle Local Overhead w Note:The use of the Agent Distribution Hose should be consid- t$ A salamander broiler with a maximum hazard area (Internal 1 ered when protecting a salamander broiler/range combination broiler chamber)of 16 in. (406 mm)deep x 29 in. (738 mm)wide • appliance that employs casters. •can be protected using a 1N nozzle.The nozzle is stamped with A salamander broiler with a maximum hazard area (internal 1N, indicating that this is a one-flow nozzle,ti broiler chamber)of 15 in.(381 mm)deep x 31 in. (787 mm)wide The single 1N nozzle must be located directly in line with either • can be protected using a 1N nozzle.The nozzle is stamped with vertical edge of the broiler opening,6 in.(152 mm)to 12 in.(304 1N, indicating that this is a one-flow nozzle. mm)in front of the broiler,and 0 in.to 12 in.(304 mm)above the . The single 1N nozzle must be affixed to the side of the cooking top of the broiler.The nozzle must be aimed at the center of the • chamber, above the grate on either vertical edge of the broiler broiler opening. See Figure 4-57a. opening.The nozzle must be aimed at the center of the grates. VERTICAL EDGE See Figure 4-57c. OF BROILER OPENING IN NOZZLEL.: (PART NO.419335) NozzLE ' 12 IN. %-.1---LOCATION ZONE 11' 4.41:1 ) \ 1 / (3°4 mcn),1 6 IN.(152 mm) t , 1 : / l BIN. ij .."1.1 .: (152 mm) lig 4 , NM AT CENTER AIM AT CENTER OF OF BROILER BROILER OPENING OPENING FIGURE 4-57a 4 .,. ,N„ci„,F,,,m., scam AT CENTER OF GRATES Salamander Broiler Protection- 1F(1-Flow) Nozzle FIGURE 4-57c Overhead 006.2h A salamander broiler with a maximum hazard area (internal broiler chamber) of 15.5 in. (393 mm) deep x 31 in. (787 mm) •wide can be protected using a 1F nozzle.The nozzle is stamped Upright Broiler/Salamander Protection with 1F, indicating that this is a one-flow nozzle. The R-102 system uses two 1/2N Nozzles for all upright broiler •protection. The nozzle is stamped 1/2N, indicating that this is The single 1F nozzle must be located directly in line with the a half-flow nozzle. A pair of these nozzles will equal one flow s center of the broiler opening, 8 in. (203 mm)to 12 in. (304 mm) number. in front of the broiler and 12 in. (304 mm) to 18 in. (457 mm) above the top of the broiler. The nozzle must be aimed at the Two 1/2N nozzles will protect a maximum hazard area(internal center of the top broiler opening when the grate is located in the broiler chamber)of 30 in. x 32.5 in.(761 mm x 825 mm).These middle position. The nozzle must be orientated so the nozzle nozzles must always be used in pairs on an upright broiler.One tip flats are parallel with the grate left to right centerline. See nozzle must be positioned above the grate and pointed at the Figure 4-57b. back opposite corner of the broiler chamber.The second nozzle must be pointed down into the center of the drip pan through the I F NOZZLE--•-? NOZZLE a IN. open slot. See Figure 4-58. LOCATION ZONE PART NO, . 052 mm) 4 19333) , i t IN.(203 ma) ,...t —1 12 IN, , LA\ 4 IN, (101 mm ,(3°4 mm) 1 ,-Sleiteri, _ AIM AT CENTER OF THE AIM AT CENTER OF THE TOP 6 TOP BROILER OPENING BROILER OPENING WHEN THE WHEN THE GRATE GRATE IS LOCATED IN THE IS LOCATED IN THE MIDDLE POSMONAIM AT CENTER MIDDLE POSITION OF BROILER OPENING FIGURE 4-57b COWS I SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual • UL EX3470 ULC EX3470 PAGE 4-24 REV, 11 2014-SEP-01 Upright Broiler/Salamander Protection (Continued) "Electric Char-Broiler Protection(Optional) The R-102 system uses the 1N nozzle for electric char-broiler UPRIGHT BROILER BROILER CHAMBER protection. e I The nozzle is stamped with a 1N, indicating that this is a one-flow nozzle and must be counted as one flow number. 1MA One 1N nozzle will protect a hazard with a maximum length of 1! .01111111111-TIVA 34 in.(863 mm)and a total cooking area which does not exceed 'Ono. 680 in. (43870 mm2). The nozzle tip must be located 20 in. to 1 I III 50 in. (508 mm to 1270 mm) above the hazard surface. When using this nozzle for electric char-broiler protection, the nozzle ih-... E...-..... .... must be positioned anywhere along or within the perimeter of DRIP PAN MEM the maximum cooking area and shall be aimed at the center of the cooking surface. See Figure 4-59b. I cookzio 1 VIEW FRONT SIDE VIEW AREA I I i I --;',;,------- FIGURE 4.58 COOKING 111001b A41,/ AREA 003252 CCVM Gas-Radiant/Electric Char-Broiler Protection The R-102 system uses the 1N nozzle for gas-radiant/electric 0 char-broiler protection. I i 1 50 IN .The nozzle is stamped with a 1N, indicating that this is a I i i (1270 rnrr) t ‘ , one-flow nozzle and must be counted as one flow number. I i MAXIMUM.tL One 1N nozzle will protect a hazard with a maximum length of ,../i 20 IN(5013 rnmI 36 in.(914 mm)and a total cooking area which does not exceed MINIMUM 864 in.2 (55741 mm2). The nozzle tip must be located 15 in, to 1 i 40 in. (381 mm to 1016 mm) above the hazard surface. When OX4257 using this nozzle for gas-radiant/electric char-broiler protection. the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at FIGURE 4-59b the center of the cooking surface. See Figure 4-59a. 1. COOKING AREA COOKING por--"Alia AREA COMB fJ \ /11---f i 1 40 IN. I 1 $ I , 1 (1016 titm) MAXIMUM 15 IN (381 mil I MINIMUM I I + cce257 -, FIGURE 4-59a R-102 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 ,.. 2014-SEP-01 REV. 11 PAGE 4-25 Lava Rock(Ceramic)Char-Broiler Protection Natural Charcoal Broiler Protection The R-102 system uses the 1N nozzle for all lava rock char- The R-102 system uses the 1N nozzle for all natural charcoal 1, broiler protection. The nozzle is stamped with 1N, indicating P.broiler protection. The nozzle is stamped with 1N indicating that this is a one-flow nozzle and must be counted as one flow that this is a one-flow nozzle and must be counted as one flow number. number. One 1N nozzle will protect a hazard which has a maximum One 1N nozzle will protect a hazard area which has a maximum length of 24 in. (609 mm) and a total cooking area which does length of 24 in. (610 mm) and a total cooking area which does not exceed 312 in.2 (20128 mm2). The nozzle tip must be not exceed 288 in.2 (18580 mm2), The nozzle tip must be located 18 in.to 35 in. (457 mm to 889 mm) above the hazard located 18 in.to 40 in.(457 mm to 1016 mm)above the hazard surface. When using this nozzle for lava rock (ceramic) char- surface. When using this nozzle for natural charcoal broiler broiler protection,the nozzle must be positioned anywhere along protection, the nozzle must be positioned anywhere along or or within the perimeter of the maximum cooking area and angled within the perimeter of the maximum cooking area and aimed at to the center. See Figure 4-60. the center of the cooking surface.See Figure 4-61. COOKING __ The coverage of such appliances only applies when the depth of Ve- AREA the charcoal does not exceed 4 in. (101 mm). •-....,....... .....1-..., i ,..-- .........cooKING f<,.... 1 •,..... AREA AREA i1 ,...... 1 1 ( 1 i---1---- 1 1 I 1 . I i I ..... .... ..,.. .,;--:_..... , ---:- -. .--"%--- - 1%•%1 1,14z -- OCC256 i \ i I I 35(lirl'MUM i \ / ill\\ / 7 f - i 11\1 ‘ V/°-- i—f I I 0018 rnm) MAXIMUM 4 i \ 18 IN. 1 \ / (457 Mtn) I ‘ MINIMUM i 41N.(101 mm) NI\ 4244 )47 1 I,,.._______._,.....„._.„„„.„..._.________........„.... . MAXIMUM I i (457 mm) umpoimpailligPiPIIIIIMIne =one DEPTH I MINIMUM .. 111 IIIIIIIIIIIHIIIIIIIIIII i 111111111111111111.1.11111111 IFtz: -...r.".1.11 020206 qi IIIIIIIIIIIHIIIIIIIIIII I IIIIIIIIIIIIIIMIMPIIIIIIIII FIGURE 4-60 g.. FIGURE 4-61 SECTION 4—SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-26 REV. 11 2014-SEF-01 Alternate Ceramic/Natural Charcoal Char-broiler Protection Wood Fueled Char-Broiler Protection The Ft-102 system may also use the 3N nozzle for all ceramic The R-102 system uses the 3N nozzle for mesquite char-broiler (lava rack) and natural charcoal char-broiler protection. The .protection.The nozzle is stamped with 3N indicating that this is ' nozzle is stamped with 3N, indicating that this is a three-flow a three-flow nozzle and must be counted as three flow numbers. nozzle and must be counted as three flow numbers. One 3N nozzle will protect a hazard which has a maximum One 3N nozzle will protect a hazard which has a maximum length of 30 in. (762 mm) and a total cooking area which does length of 30 in. (762 mm) and a total cooking area which does not exceed 720 in.2 (46451 mm2). The nozzle tip must be not exceed 720 in.2 (46451 mm2). The nozzle tip must be located 14 in. to 40 In. (355 mm to 1016 mm)above the hazard located 14 in. to 40 in. (355 mm to 1016 mm)above the hazard surface. The nozzle must be positioned anywhere along or surface. The nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and aimed at within the perimeter of the maximum cooking area and angled the center of the cooking surface. See Figure 4-63. to the center. See Figure 4-62. Mesquite logs and pieces,no larger than 4 in.(102 mm)in diam- For natural charcoal char-boiler protection, this coverage only eter, may be protected with a maximum allowable wood depth applies when the depth of the charcoal does not exceed 4 in. of 6 in. (152 mm). (101 mm). COOKING......4,...,... COOKING AP"11,... COOKING AREA COOKING ..*'-- AREA AREA AREA ,---1--, ---•••...---- •-•.. ,---1---- --'--,... , ,.... .--. f<--- I - I . 1 r-- ..... I -.., -. >1 -..., 1 ,; . -...,... I I --r--- ..... 1,---,-- , , , , , , I , , ..., I cmac IWVCC 1\ 113 7 11\ I 1 4133 / 1 I ‘ I / 40 tNi. MI6 rran) \ /1:1-7,44Ax(4Q1°11Neimmurnm)1 ....,,,. \ i MAXIMUM 4 N. i\ \ tt33 / P1:47: 5 IN.(125 mrn) : 14 IN MAXNUNI i i / (355 mm) I (101 rrun) I DEPTH " / 1 (355 mm) I MINIMUM MAXIMUM I / DEPTH I % ) MINIMUM I I I I 1 1 1 li'k,.. omomeomll XCIISO 1114. 0111.1.11...II CCOISS MIIIIIIIIIIIIIIIIII IIIIIIIIIIIIHIIIIIIIII 1111111111111111111.1111111111 1111111111111. 4 4 FIGURE 4-63 FIGURE 4-62 R-702 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-27 Wok Protection 2. A 1N nozzle will protect a wok 11 in. (279 mm) minimum diameter up to 24 in.(609 mm)maximum diameter.The wok The R-102 system uses two different nozzles for the protection of woks. depth must be no less than 3 in. (76 mm) and no greater * than 6 in. (152 mm). The nozzle is stamped with 1N indi- 1. A 260 nozzle will protect a wok 14 in. (355 mm) minimum cating that this a one-flow nozzle and must be counted as diameter up to 30 in.(762 mm)maximum diameter.The wok one flow number. When using this nozzle, the nozzle must depth must be no less than 3.75 in. (95 mm)and no greater be positioned anywhere along or within the perimeter of the than 8 in. (203 mm). wok, aimed at the center, 30 in. to 40 in. (762 mm to 1016 The nozzle is stamped with 260 indicating that this is a mm) above the hazard surface,as shown in Figure 4-65. two-flow nozzle and must be counted as two flow numbers. NOTICE When using this nozzle, the nozzle must be positioned as shown in Figure 4-64, When using this type of wok protection, only five flow numbers are allowed on a NOZZLE MUST SE POSITIONED WITHIN'I IN (25 mull RAMS 1.5 gal (5.7 L) system, and only eleven OF THE CENTER OF THE WOK,POINTED VERTICALLY DOWN flow numbers are allowed on a 3 gal(11.4 L)system, \. tg1 ('.?; II\ 'i 11 i II 40 N. 1 (10.16 mm) 280 NOZZLE oil G, IN t 6. /2111—T 1 1 i 35-45 IN. MINIMUM DEPTH ....L. I Min) Meg-1143 mm) 3.0 IN.(76 mm) MAXIMUM DEPTH MINIMUM DEPTH 3,75 IN,(95 mm) 1 8.0 IN.(152 mm) t MAX:MUM DEPTH BIN : I 11 IN.(279 mm)MINIMUM DIAMETER 24 IN,(609 mm)MAXIMUM DIAMETER 14.....0e4-1- 1 t * a I FIGURE 4-65 0=1 14 IN.(355 mm)MINIMUM DIAMETER 30 IN.(762 mm)MAXIMUM DIAMETER FIGURE 4-64 meal ! , ,, SECTION 4—SYSTEM DESIGN R-1 02 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-28 REV. 11 2014-SEP-01 Nozzle Application Chart The following chart has been developed to assist in calculating NOTICE the quantity and type of nozzle required to protect each duct, This chart is for general reference only. See plenum, or appliance, complete details for each type of hazard. Minimum Nozzle Maximum Hazard Nozzle Nozzle Nozzle Stamping— Hazard Dimensions Quantity Heights Part No. Flow No, Duct or Transition Length—Unlimited f — 439839 1W (Single Nozzle) Perimeter—50 in. (1270 mm) Diameter—16 in, (406 mm) Duct or Transition Length—Unlimited 1 — 439840 2W (Single Nozzle) Perimeter—100 in. (2540 mm) Diameter—31 7/8 in. (809 mm) Duct or Transition Length—Unlimited 2 — 439840 2W (Dual Nozzle) Perimeter—150 in. (3810 mm) Diameter—48 in. (1219 mm) Electrostatic Precipitator Individual Cell 1 ? 1/2N (At Base of Duct) Plenum Length—10 ft(3.0 m) 1 — 439838 1 N (Horizontal Protection) Plenum Length—6 ft(1.8 m) 1 — 439839 1W ►(Horizontal Protection) Width—4 ft(1.2 m) Plenum Length—4 ft(1.2 m) 1 — 439839 1W (Vertical Protection) Width—4 ft(1.2 m) Fryer(Split or Maximum Size Non-Split Vat) (without drip board) 14 in. (355 mm) x 15 in. (381 mm) 13—16 in. 439845 290 Low Proximity (330—406 mm) Fryer(Split or Maximum Size Non-Split Vat) (without drip board) 14 1/2 in. (368 mm)x 14 in. (355 mm) 1 16—27 in. 439845 290 Medium Proximity (406—685 mm) Fryer(Split or Maximum Size Non-Split Vat)' (without drip board) 15 in. (381 mm) x 14 in. (355 mm) High Proximity 1 27—47 in. 439842 230 Medium Proximity 1 20—27 in. 439843 245 Fryer(Non-Split Vat Only) Maximum Size (without drip board) 19 1/2 in. (495 mm)x 19 in. (482 mm) High Proximity 1 21 —34 in. 439841 3N Low Proximity 1 13-16 in. 439845 290 Maximum Size (without drip board) 18 in. (457 mm) x 18 in.(457 mm) High Proximity 1 25—35 in. 439841 3N (635—889 mm) -Fro,ayttide,oz?N o .eton Of W.V.fry.re,see o.gd+eo 6-0arnaUwi On wages 4-1Q a'm 4•1 t. R-702 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-29 Nozzle Application Chart (Continued) Minimum Nozzle Maximum Hazard Nozzle Nozzle Nozzle Stamping- Hazard Dimensions Quantity Heights Part No. Flow No. Fryer(Non-Split Vat Only) Maximum Size (Continued) (without drip board) 14 1/2 in. (368 mm) x 16.5 in.(419 mm) High Proximity 1 16-21 in. 439845 290 (406-533 mm) Fryer(Non-Split Maximum Size Vat Onlyy (with drip board) 21 in. (533 mm)x 14 in. (355 mm) (Fry Pot must not exceed 15 in. x 14 in, (381 mm x 355 mm)) High Proximity 1 27-47 in. 439842 230 (685-1193 mm) Medium Proximity 1 20-27 in. 439843 245 (508-685 mm) Maximum Size (with drip board) 25 3/8 in. (644 mm) x 19 1/2 in. (495 mm) (Fry pot side must not exceed 19 1/2 in. (495 mm)x 19 in. (483 mm) High Proximity 1 21 -34 in, 439841 3N (533-863 mm) Low Proximity 1 13-16 in, 439845 290 (330-406 mm) Maximum Size (with drip board) 18 in. (457 mm) x 27 3/4 in. (704 mm) High Proximity 1 25-35 in. 439841 3N (635-889 mm) Maximum Size (with drip board) 14 1/2 in. (368 mm) x 26.5 in.(673 mm) High Proximity 1 16-21 in. 439845 290 (408-533 mm) Fryer(Split or Maximum Size Non-Split Vat) (with drip board) 14 in. (355 mm)x 21 in. (533 mm) 1 13—16 in. 439845 290 Low Proximity (330-406 mm) Fryer(Split or Maximum Size Non-Split Vat) (with drip board) 14 1/2 in. (368 mm)x 26 1/2 in. (673 mm) 1 16-27 in. 439845 290 Medium Proximity (406-685 mm) • For multipie nozzle protection of single fryers,see oetaileC Information on Pages 4-10 ana 4-11, /i /IFKAYN/1@A\`/iNMMf:uAMv//l/NrrRMrr!/.HN'r+inrr f nrf::t+aNliMYi, �earNtl/.w...---..w�. . , SECTION 4—SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 430 REV. 11 2014-SEP-01 Nozzle Application Chart (Continued) • Minimum Noule Maximum Hazard Nozzle Nozzle Nozzle Stamping— Hazard Dimensions Quantity Heights Part No. Flow No. Range Longest Side(High Proximity) 1 30—40 in. 439838 1 N 32 in. (812 mm) (762— 1016 mm) Area—384 in.2 (24774 mm2) Longest Side(Low Proximity) 1 15—20 in. 439838 1 N 24 in. (609 mm) (381 —508 mm) Area—432 in.2 (27870 mm2) Longest Side 40—48 in. 439836 1 F 28 in. (711 mm) (1016— 1219 mm) Area—336 in.2 (With Bookshelf) (21677 mm2) • Longest Side 30—40 in. 439844 260 32 in. (812 mm) (762—1016 mm) Area—384 in.2 (With Bookshelf) • (24774 mm2) Longest Side(High Proximity) 1 40—50 in. 439843 245 28 in. (711 mm) (1016—1219 mm) Area—672 in.2 (43354 mm2) Longest Side (Medium Proximity) 1 30—40 in. 439844 260 32 in. (812 mm) (762—1016 mm) Area—768 in.2 (49548 mm2) Longest Side(Low Proximity) 2 15—20 in. 439845 290 36 in. (914 mm) (381 —508 mm) Area—1008 in.2 (65032 mm2) Griddle Longest Side(High Proximity) 1 30—50 in. 439$44 260 48 in. (1219 mm) (762—1270 mm) Area— 1440 in.2 (perimeter (92903 mm2) located) Longest Side(High Proximity) 1 30—50 in. 439845 290 30 in. (762 mm) (762—1270 mm) Area—720 in.2 (center located) (46451 mm2) Longest Side(High Proximity) 1 35 — 40 in. 439838/439865 1 N/i NSS 36 in. (914 mm) (889—1016 mm) Area— 1080 in.2 (69677 mm2) (perimeter located) Longest Side 1 20—30 in. 439845 290 (Medium Proximity) (508—762 mm) 48 in. (1219 mm) (perimeter Area— 1440 In.2 located) (92903 mm2) Longest Side(Low Proximity) 1 15—20 in. 439839 1W 26 in. (660 mm) (381 —508 mm) Area—533 in.2 (center located) (34387 mm2) 1 1 R-702 Restaurant Fire Suppression Manua! SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 I . .. 2014-SEP-01 REV. 11 PAGE 4-31 Nozzle Application Chart (Continued) Minimum Nozzle Maximum Hazard Nozzle Nozzle Nozzle Stamping— Hazard Dimensions Quantity Heights Pan No. Flow No. Griddle(Continued) Longest Side(Low Proximity) 1 10—20 in. 439840 2W 36 in. (914 mm) (254—508 mm) Area—1080 in.2 (perimeter located) (69677 mm2) 4 Longest Side(Low Proximity) 1 10—20 in. 439846 2120 48 in. (1219 mm) (254—508 mm) Area—1440 in.2 (perimeter (92903 mm2) located) * Chain Broiler Length—34 in. (863 mm) 2 10—26 in. 439839/439864 1W/1WSS * (Overhead Protection) Width—32 in. (812 mm) (254—660 mm) Chain Broiler Length—43 in. (1092 mm) 2 1 —3 in. 439838/439865 1N/1NSS (Horizontal Protection) Width—31 in. (787 mm) (25—76 mm) ; * Gas-Radiant/Electric Longest Side—36 in. (914 mm) 1 15—40 in, 439838/439865 1N/1NSS Char-Broiler Area—864 in.2 (381 —1016 mm) (55741 mm2) Electric Char-Broiler Longest Side—34 in. (863 mm) 1 20—50 in. 439838/439865 1N/1NSS Area—680 in.2 (508—1270 mm) (43870 mm2) Lava-Rock Broiler Longest Side—24 in. (609 mm) 1 18—35 in. 439838/439865 1N/1NSS Area—312 in.2 (4-57—889 mm) (20128 mm2) Natural Charcoal Broiler Longest Side—24 in. (609 mm) 1 18—40 in. 439838/439865 1N/1 NSS I Area—288 in.2 (457.7-1016 mm) (18580 mm2) Lava-Rock or Natural Longest Side—30 in. (762 mm) 1 14—40 in. 439841 3N Charcoal Char-Broiler Area—720 in.2 (355—1016 mm) (46451 mm2) Wood Fueled Char-Broiler Longest Side—30 in. (762 mm) 1 14—40 in. 439841 3N Area—720 in.2 (355— 1016 mm) (46451 mm2) Upright Broiler/ Length—32.5 in. (825 mm) 2 — 439837 1/2N ' Salamander Width—30 in. (762 mm) Salamander Length—29 in. (736 mm) 1 — 439838 1N Broiler Width—16 in. (406 mm) Length—31 in. (787 mm) 1 — 439836 1F Width—15 in. (381 mm) Length—31 in, (787 mm) 1 — 439838 1N Width—15 in. (381 mm) Wok 14 in.—30 in. (355—762 mm) 1 35—45 in. 439844 260 Diameter (889—1143 mm) 3.75—8.0 in. (95—203 mm) Deep 11 in.—24 in. (279—609 min) 30—40 in. 439838/439865 1N/1NSS ., Diameter (762—1016 mm) 3.0—6.0 in. (76—152 mm) Deep ' Minimum chaml UMW exhaust opening—12 In.x 12 In,(3E35 rnm x 305 Mtn),ens not toss man 60%ol internal brodar sas ._-- , ti,MlAipBWNp1//ff4'FA tMIGV Y/0..14JN lWileiM.M4'.,,..,nY.14 1.590sY4N1.1.41 Inal...**04"....wMww.u... SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-32 REV. 11 2014-SEP-01 SPECIFIC APPLICATION BY MODEL FRY POT CENTERLINE Due to the configuration, application, and/or additional features 8IN. C- 1 1/81N. (233 mil) 1 1/8 IN. -+. that pose protection problems using conventional protection, {28 ( mm) mm) noted in the guidelines previously addressed,the following appli- 1w NOZZLE ances/applications are considered hazard specific. 6 IN. ---.i 29°NOZZLE---. , 152 mm) IN\ The following hazard specific applications have been individually tested and listed by make and model number of the equipment I AIM POINT ; I { 1 73/4-8IN.ONLY designated, � ` m TOP OF (196-203m) Dean Industries Gas Fryer, Model 2424 GTI, 120,000 BTU/ 1---, f'"hr. Rating LOW PROXIMITY(7 3/4-8 IN. (1%-203 mm) N NOZZLE HEIGHT) This specialized gas fryer can be protected with a combination of a 290 nozzle and a 1W nozzle for low proximity (7 3/4-8 in. 2 1/4 IN —(2 7.4 IN. {57 mm) (197-203 mm) nozzle height only) and two 230 nozzles (Part (57 mm)---I NOZZLE No. 419339)for high proximity(45 in. (1143 mm) nozzle height AY Only). FRONT EDGE OF FRY PCT 230 NOZZLE I ? I The maximum dimension of the fry pot is 24 in.x 24 in, (610 mm 11 IN. x 610 mm). (279 mm) 4G i Nozzles must be positioned and aimed as shown in Figure 4-66. 1 45 IN.ONLY (1143 mm) / �i TOP OF FRYER Note: For low proximity protection, see Special Piping Layout !'_ in Figure 4-67. • I I OC62RA AIM POINT 1 Ell HIGH PROXIMITY(45 IN,(1143 mm)NOZZLE HEIGHT ONLY) FIGURE 4-66 Section B (Hood Penetration to Nozzles)Piping Limitations Dean Industries Model GTI Gas Fryer Special Piping Layout 1. Piping configuration shall be as shown with t1/4 in. (6 mm) tolerance on dimensions. Section A(Tank to Hood Penetration) Piping Limitations 2. All nozzles shall be at the same elevation. Maximum Length:30 ft(9,1 m) Maximum Rise: 6 ft (1.8 m) 3. Each pair of appliance nozzles shall be equally spaced from Maximum Number of 90° Elbows:7 left-to-right centerline of fryer. r Maximum Number of Tees:0 • 1w 290 TO3 GAL(t1.4L)TANK 141111°. • ' 1W SECTION290 A 2 1/4 IN. 2 3!a IN. 21 IN.(533 mm)or (57 mm) 2 1 8 2a IN.(603 mm) (53 mm) (09 ) HOOD PENETRATION \ • / ...40.441Pri \ 8 114 IN. 290 21 IN.(533 mm)rx 2 1/4 IN, (239 mm) 24 IN.(6D9 mm) (57 Win) r 29 5/8 IN. 0094 (752 mm) 290 2 11/16 IN. (68 mm) 1W 21 IN.(533 mm)or (57 mfr) j 24 IN.(609 mm) 0414 21/4 IN. (57 mm) SPECIFIC DISCHARGE PIPING FOR LOW PROXIMITY PROTECT'ON OF FOUR DEAN INDUSTRIES MODEL GTI GAS FRYERS FIGURE 4-67 ocaza• ........„............ ... ........ . ... . .......„......... ___„.,..........„..„.....,.„„_„.„.„.„_______.„„„,,„,,,_,._,,,,, R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-33 SPECIFIC APPLICATION BY MODEL(Continued) Far West Hospitality Products Gas Fryer, Model PAR-1-20, Frymaster 14 KW-208V Electric Fryer, Model MACH 14 63000 BTU/hr Rating Series This specialized gas fryer can be protected with a single. 290 This specialized single vat electric fryer can be protected either nozzle. with a single 230 nozzle located 27 in. to 47 in. (685 mm to 1193 mm)above the top surface of the fryer or with a single 245 The maximum dimension of the fry pot is 21 in. x 21 in. (533 nozzle located 20 in. to 27 in. (508 mm to 685 mm) above the mm x 533 mm). top surface of the fryer. The 290 nozzle must be located on the front-to-rear centerline and aimed at the center of the cooking surface.See Figure 4-68. Either nozzle must be located anywhere along or within the perimeter of the cooking surface and aimed at the midpoint. 4 I/21N. See Figure 4-69. The maximum size of the fry pot(without drip (114 mm) / \ board) is 13 3/4 in. x 16 3/4 in. (349 mm x 425 mm) and the i• •I,o _i maximum size of the cooking surface(with drip board) is 13 3/4 in. x 20 7/8 in. (349 mm x 530 mm).The vat may be divided in --11—/ half to make two split vats. 230 NOTAF TIP OR 245 NOZZLE Tip ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE COOIONG SURFACE AND AIMED AT THE MIDPOINT, 14 IN t \1 ii 230 NOZZLE (355 rnm) 13 N. 20 VS IN. 1 < MAXIAVA (330 mm) (539 mm) ": BACK .....,../P'\,............ 11..„........„.../.."f: i --' 2a0 NOTZE OF <1.,..------- 245 27 IN -47 IN, FRYER NOZZLE (685 mm- 5 13 3/4 ITIOWP3 SmUmPiFAC EV- (349 mm) ' OF FRYER MAXIMUM 1 1 1 , SIDE VIEW OF FRYER I I 245 NOZZLE 27 I 20 IN.- IN. c44:00 I 1 008 rnm- 685 mm) 1 I ABOVE TOP SURFACE OF 290 NOZZLE LOCATED ON FRONT-TO-REAR CENTERLINE 4 4.5 IN.(114 mm)FROM I I FRYER SIDE TO SIDE CENTERLINE AND AIMED AT CENTER OF COOKING AREA, ' I ' 11101/1111111 i . IrOffilig ,.-...,i .-,-.,,,.,-.• ,,,,!.. ''''''41 1111111111111111111114044.60. ZirA1 .1° 15 3/4 IN.(425 Mill) MAXIMUM f: 0.410\ PPP . 13 1.1. 14 IN. (330 mm) FIGURE 4.69 i (355 mm) ccomo 1 oct404 FIGURE 4.68 • I , 1 . SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-34 REV. 11 2014-SEP-01 SPECIFIC APPLICATION BY MODEL(Continued) REAR 0 Frymaster Energy Efficient RE 14 Fryer FRONT•TO-REAR This electric fryer can be protected with either a single 230 VAT CENTERLINE nozzle located 27 to 47 in. (685 mm to 1193 mm)above the top i surface of the fryer or with a single 245 nozzle located 20 to 27 in. (508 mm to 685 mm)above the top surface of the fryer. RIGHT-TO-LEFT VAT Either nozzle must be located anywhere along or within the CENTERLINE perimeter of the cooking surface and aimed at the midpoint. 4/Paw. I See Figure 4-70.The maximum size of the fry pot(without drip i board) is 14 x 15 1/2 in.(355 mm x 393 mm)and the maximum NOZZLE MIL i I 3 114 IN, size of the cooking surface (with drip board) is 14 x 20 7/8 in. LOCATION ?•- 1(82 mrn) ZONES / (355 mm x 530 mm). The vat may be divided in half to make SI 2 IN. (51 two split vats. mm) 2 1/4 IN. 2 I m IN 230 NOZZLE T1P OR 245 NOZZLE TIP ANYWHERE ALONG OR WITHIN THE PERIMETER (57 mm) , (57 mm) OF THE COOKING SURFACE AND AIMED AT THE MIDPOINT. 20 7/8 IN ........„...>4s+ 230 NOZZLE (530 mm) MAXIMUM FRONT FIGURE 4-71 <J>11 245 27 IN,-47 IN. 14 IN NOZZ-E (685 mm- 1193 mm)ABOVE 5 I 1cons-, I / TOP SURFACE 2.The distance between the start of the first branch line and the (35 mm) 1 I ..; OF FRYER start of the last branch line shall not exceed 79 in.(2006 mm). MAXIMUM I 1 I 1 I 1 I 245 NOZZLE 3. The total length of all branch lines shall not exceed 162 in, (508 mm-20 IN-27 IN. (4114 mm). I I I I 555 mm) I I I ABOVE TOP I 4. The 3 gallon agent tank shall be elevated above the connec- SURFACE OF .... I I ' I Pimp; 1 tions between the supply and branch lines. 5. The requirements of the following table shall not be -iilf t.00 Requirement exceeded: Pipe Size Duct 3/8 in. Plenum Appliance 3/8 in. 3/8 in. 3/8 in, i Line eply LBirnaenoh Line Line Branch Branch 15 1/2 IN (393 mra) Maximum Length 140 in. 67 in. 6 in. 42 in. MAXIMUM (3556 mm)(1701 mm) (152 mm) (1066 mm) . FIGURE 4-70 Minimum Length 81 in. 4 in. 4 in. 17 in. (2057 mm)(101 mm) (101 mm) (431 mm) McDonald Fryer(Nozzle Heights of Less Than 20 In. Maximum 5 3 1 6 (508 mm)) 90° Elbows When the 245 nozzle is used to protect McDonald's fryers at Maximum Tees 0 1 1 1 heights less than 20 in. (508 mm)above the top of the fryer,the Maximum Flow 11 2 1 2 following appliance and distribution piping rules shall apply: Numbers 1. Each McDonald's gas or electric fryer shall be protected by Minimum Flow 5 0 0 1/2 one 245 nozzle. The fryer vat dimensions for one full vat or Numbers two split vats shall not exceed 14 in.x 15 in.(355 mm x 381 mm)without the dripboard and 14 in.x 21 in.(355 mm x 533 mm)with the dripboard. The heat input rating of the fryer shall not exceed 122,000 BTU/HR. The 245 nozzle shall be located 18 in. to 20 in. (457 mm to 508 mm) above the top of the fryer vat, 2 in. to 2 1/4 in. (51 mm to 57 mm)to the right or left of the front-to-rear vat centerline, and 0 to 3 1/4 in. (0 to 82 mm) forward of the right-to-left vat centerline,and aimed at the vat center point. See Figure 4-71. R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-35 SPECIFIC APPLICATION BY MODEL(Continued) Henny Penny Mono Rail Center Lift System-Models 690, Note: In this application. R-102 agent storage tanks must 691, 692 be pressurized from a dedicated R-102 double-tank nitrogen Nozzle Type: One 1 N nozzle (Upper position) cartridge. The cartridge utilized for this hazard-specific Henny One 1F nozzle(Lower position) Penny fryer protection cannot be shared with tanks intended for standard R-102 protection. Standard protection will require Nozzle Location: an expellant gas cartridge installed in another actuation device 1N Nozzle (Upper position): From the Tee Block, position such as an AUTOMAN regulated release or regulated actuator nozzle tip 16 in. (406 mm) up from base of fryer surface and 5 assembi in. (127 mm)in from right side of appliance back shroud 1F Nozzle(Lower Position): Running down from the Tee Block to the base of the fryer,position the nozzle tip 2 in. (51 mm)from back side of fry vat,and 8 in. (203 mm)in from the right side of appliance back shroud Nozzle Aiming Point: 1N Nozzle: At center point of fry vat 1F Nozzle: The 1F nozzle is a flat spray nozzle and the spray must be horizontal to that of the edge of the back lip of the fry vat System Coverage: Each fryer requires a minimum of 3 gal (11.4 L)of ANSULEX Low pH agent discharging through the two one-flow nozzles ON and I F) AIMING POINT NOTE 1:IT IS RECOMMENDED THAT THE AGENT DISTRIBUTION HOSE KIT(PART NO.4159P0)BE UTILIZED DURING SYSTEM INSTALLATION. ''''';''.....". """...""..... 444 ma-...;. ."--"L Ill IF — NOTE 2.VAT DIMENSIONS- 18 if4.(408 rom)WIDTH 20 1/4 IN.(514 mm)LENGTH 28 1/2 IN.(724 mm)DEFTH MAXIMUM UD HEIGHT ABOVE VAT- ill 1111111111111111111111 15 94.(381 nun) 8 IN, .1.11.1.111.11.11Et...1111.1.1111.1111111111 (203 mm) TEE 7 9/16 IN. TOP VIEW 5 IN. BLOCK (192 Mm) (127 mm) .11,1111111111..1,011Mal rd..' 111.1111111.111.111.• 0111. 1111 18 13/18 IN. 111 (15 IN. (AZ/mm) 0--•-- az= lir ,..;, i Nliiiii.:-.. monsimosmis •••••••••••••••••••=umm • • $ •• • .• . . , 1 (521 11111mitm) rrrill IIIIII * • - ..., C07416 or III "tr .. FRONT VIEW SIDE VIEW (TEE BLOCK LOCATION) FIGURE 4-72 1 . _ SECTION 4—SYSTEM DESIGN R-702 Restaurant Fire Suppression Manual .. UL EX3470 ULC EX3470 PAGE 4-36 REV. 11 2014-SEP-01 SPECIFIC APPLICATION BY MODEL(Continued) Note: In this application, R-102 agent storage tanks must Henny Penny Dual Lift System—Models 580, 581,582, 590, *591, 592, 680, 682, 691 be pressurized from a dedicated R-102 double-tank nitrogen cartridge. The cartridge utilized for this hazard-specific Henny Nozzle Type: One 1N nozzle(Upper position) Penny fryer protection cannot be shared with tanks intended One 1F nozzle(Lower position) for standard R-102 protection. Standard protection will require .Nozzle Location: an expellant gas cartridge installed in another actuation device 1N Nozzle (Upper position): From the Tee Block, position such as an AUTOMAN regulated release or regulated actuator nozzle tip 16 in. (406 mm) up from base of fryer surface and assembly. 5 in. (127 mm)in from left side of appliance back shroud 1F Nozzle(Lower position): Running down from the Tee Block to the base of the fryer,position the nozzle tip 2 in.(51 mm)from back side of fry vat, and 8 in. (203 mm) in from the left side of appliance back shroud. Nozzle Aiming Point: 1N Nozzle: At center point of fry vat 1F Nozzle: The 1F nozzle is a flat spray nozzle and the spray must be horizontal to that of the edge of the back lip of the fry vat System Coverage: Each fryer requires a minimum of 3 gal (11.4 L)of ANSULEX Low pH agent discharging through the two one-flow nozzles (1N and 1F) AIMING POINT 5 IN. •-• NOTE 1: IT IS RECOMMENDED THAT THE AGENT DISTRIBUTION (127'urn) ...! • HOSE KiT(PART'Na 435982)BE UTILMO PURING SYSTEM INSTALLATION. i ..... .will111111.11116111 SIN. NOTE 2: VAT PIMENSKYIS- I I lir oz.. (203 rnrn) _. 16 IN.(ADS mm)WIDTH ZI 1)4 IN.($14 rnm)LENGTH 26 1/2 IN.Ma(Tun)DEPTH MAXIMUM UP HEIGHT ABOVE VAT- : 1 15 IN.(381 mm) I TEE 7 9/16 IN. BLOCK (132 mrn) ...:' TOP VIEW ,.. I ' -•IIIIIIVAIIII 1- I,..1....i iimusicm1 !Ilill s 16 13/,6 IN. I (427 TM) ........_.... --.....--ipinik. 1 (41068 IN.n) '''''" . . 14.• I (-- I LIIIII1S111, -IiiiiiiIIIIIMEN1111L.2 allM111111111111111111111111M. 1111111111.11111111=11111•••••mmINIIIMIIIII 1 .................. II i Al 1 d 1,.., lawn 1 e)NrAIR 1 ;II .cr a is al111111111111111111101114 . , !--H' 2 IN. (51 mm) 4 •IliAl lik. • .4 ocrs:s 1 VY l.V ill FRONT VIEW SIDE VIEW (TEE BLOCK LOCATION) FIGURE 4-73 R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-37 SPECIFIC APPLICATION BY MODEL(Continued) v-Henny Penny Dual Lift System-Model PXE-100 Note: In this application, R-102 agent storage tanks must be pressurized from a dedicated R-102 double-tank nitrogen i Nozzle Type: One 1N nozzle (Upper position) cartridge. The cartridge utilized for this hazard-specific Henny One 1F nozzle(Lower position) Penny fryer protection cannot be shared with tanks intended Nozzle Location: for standard R-102 protection. Standard protection will require 1N Nozzle (Upper position): From the Tee Block, position an expellant gas cartridge installed in another actuation device nozzle tip 16.75 in. (425 mm) up from base of fryer surface and such as an AUTOMAN regulated release or regulated actuator 1.75 in. (44 mm) in from right side of appliance back shroud assembly. 1F Nozzle(Lower position): Running down from the Tee Block to the base of the fryer, position the nozzle tip 2 in. (51 mm) up from the base of the fryer surface, and 2.25 in. (57 mm)in from the right side of appliance back shroud Nozzle Aiming Point: 1N Nozzle: At center point of fry vat 1F Nozzle: The 1F nozzle is a flat spray nozzle and the spray must be horizontal to that of the edge of the back lip of the fry vat System Coverage: Each fryer requires a minimum of 3 gal (11.4 L)of ANSULEX Low pH agent discharging through the two one-flow nozzles(1N and 1F) NOTE 1 IT IS RECOMMENDED THAT THE AGENT DISTRIBUTION HOSE KIT(PART NO 435982)5E UTILIZED DURING SYSTEM INSTALLATION. NOTE 2: VAT DIMENSIONS- 14.93 IN.(379 mm)WIDTH 20.55 IN.(522 mm)LENGTH 17 42 IN.(442 mm)DEPTH HEAT OUTPUT-17kW TOP VIEW , 1,25 IN. *7)% 111111‘,0 TiI . ...: L f,",,,'?"—• 4111.14 - • ""- II--!--'11r2 .i..—. d I , I, L 1 75 IN,(44 mm) I TOP NO771 P 11 ' 20.5 IN. 16.75 IN. (WI mm) (425 mm) lig i 4101 , i '''- '1171421•... .„„,,,g.1111........'311.1:1111:44.110 2.,1,,,N,. ) ...,..4, --111111111.1111111111 , L 2.25 IN (67 mm) ..t * t." • A . ••'"'""""1"5. 11111[6 BOTTOM NOZZLE • 6 14 4.4.1410.14 $t . • .. INIUMM E1 1.1i 1,......-7„, IIV mu,;IVALL:211 j. VI dri'4111111111111111111111111111"74) 111 IT u r'hi .V) FRONT VIEW SIDE VIEW (TEE BLOCK LOCATION) (NOZZLE LOCATION) FIGURE 4-74 P. WW1 • .. , SECTION 4—SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-38 REV. 11 2014-SEP-01 SPECIFIC APPLICATION BY MODEL(Continued) NOZZLE CROSS SECTION VIEW Pitco SPINFRESH Fryer—Models MEII,MGII, SE14, SE14R, SE14X,SG144S, SG14RS, SEH50,SEH5017,SGH50, SGH5017, SSH55, SSH55R OUIK-SSEAL ADAPTOR Nozzle Quantity/Type:Two 2120 nozzles CL • One Agent Distribution Hose and Restraining Cable Kit (Pa �E NIPPLE rt No.435982) must be utilized for each fryer(see Figure 4-78) ° ELBOW • The 3/8 in. Quik-Seal mechanical bulkhead fitting (Part No. rQ ' ' 0. CLOSE NIPPLE IN N 77285) must be utilized for the connections through fryer 3 a0.1251 . cover. p a 1 TO NOZZLE TIP �--2120 Nozzle • Nozzle must be installed with the standard Metal Blow-Off Cap 1 (Part No. 439861) or the Stainless Steel Blow-Off Cap (Part I 6.25 IN.z 0,126 tN. No.439866). (159 mm t 3 mm) • Fryer electrical power source must be connected for electri- FIGURE 4-76 cal shutdown upon system actuation through the use of the 309439 ANSUL R-102 Snap Action Switch Kit (Part Nos. 423876- FRYER FLUE 423881). 1111 ti i '.375IN. (35 min)DIA. 2.5IN.*0.5IN. (64mm*13mm) O 0 I O 7 L.-- 5.0 IN.s0.5IN. (127mma13 min)—0' FIGURE 4-77 FIGURE 4-75 NI , 6 IN. 6IN. (T52-- f1�)''i. 1A.IN. (356;-m)N MEASURE TO THE CENTER OF FITTINGS AGENT DISTRIBUTION HOSE AND RESTRAINING CABLE KIT (PART NO.435532) Ow- ► FIGURE 4-78 R-102 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-39 0.SPECIFIC APPLICATION BY MODEL(Continued) BELSHAW Century Fryers—Models C100, C200,C200G, C300G, C400, C400G, C600, C600G • Nozzle Type: 3N nozzle • Nozzle Spacing: 11.5 in. (292 mm) maximum from end of fryer and 25.5 in. (647 mm) maximum on centers • Nozzle Height:35 in. (889 mm)above top of appliance • Nozzle Position:2 in. (51 mm)in from inside edge of fry vat • Nozzle Aiming Point:Along the centerline of fry vat 11.5 IN. i 26.5 IN. (292 nun) (647 mm)25,5 IN. , ' 25.5 1N.(62rn1 1 I 25 5 IN (647 mm) 25.51N. 10 , (647 nun) k A \ 11,5 IN...64,00007\ \ 0,000: % (292 nun) I \ 35 IN. WO mrn) Opp. ›,•'. -.0,1(.0? q,. .44'7N' I LI I I I cam. , FIGURE 4-79 BELSHAW Century Fryers Specifications C100 C200 C200G C300G C400 C400G C600 C600G Fryer Vat Size Length: Inches 65 65 65 65 122.25 122 122.25 122 (mm) (1651) (1651) (1651) (1651) (3105) (3099) (3105) (3099) Width: inches 12 20 20 31.25 20.25 21.25 31 31.25 (mm) (305) (508) (508) (794) (514) (540) (787) (794) Depth: Inches 5.25 5.25 9.75 9.75 6.25 11.25 7.12 11.00 (mm) (133) (133) (248) (248) (159) (286) (181) (279) BTU Rating: K — — 188 200 — 350 — 360 Vat OH Capacity: Lb 110 188 346 700 478 600 675 1250 (kg) (49.8) (85.2) (156.9) (317.5) (216.8) (272.1) (306.1) (566.9) ,,,11lA�11M014,•'.4.4!/.1 .44.1/0/ar ir 4e 41.60..r................w:.:.... .•••,•n...,..n.........e....r.....r..pn..nN4r,». s Inadeeao”......imr+v...,.n...a• . SECTION 4—SYSTEM DESIGN R-702 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-40 REV. 11 2014-SEP-01 SPECIFIC APPLICATION BY MODEL(Continued) s Krispy Kreme Fryers—Models 55M, 65 D/H, 110 D/H, 110M, Dunkin Donuts Fryer Model DD400CGF P. 150 DM,220M, 270 Dili,600 DM, and 1000 D/H • Nozzle Type:3N nozzle Nozzle Type: 3N nozzle • Nozzle Spacing: 11.5 in. (292 mm) maximum from end of Nozzle Spacing: 11.5 in. (292 mm)maximum from end of fryer and 25.5 in. (647 ram)maximum on fryer and on maximum 25.5 in. (647 mm) centers centers Nozzle Height: 35 in. (889 mm)above top of appliance • Nozzle Height:35 in. (889 mm) above top of appliance Nozzle Position: 2 in.(51 mm)from inside edge of fry vat • Nozzle Position: 2 in. (51 mm) in from inside edge of fry vat Nozzle Aiming Point:Along centerline of fry vat • Nozzle Aiming Point:Along the centerline of fry vat Note: Figure 4-81 shows maximum size fryer(Model 1000 D/H). Smaller size fryers(Models 150 D/H,270 DM,and 600 D/H)can be protected with less nozzles but nozzle spacings, height 25.5 IN. requirements, and positions, must be maintained as shown in sal mm) Figure 4-81. 25.5 IN. 1 p IN. (647 mm) (254 mm) 11.5 1N. 25.5 IN. (292 mm) 25.5 IN. (647 mrr) 10 IN. (254 mm' (647 mm) 25.5 IN. or IN. (84..mm) {647 mm) 25.5 IN. N. 25,5IN. (641 m) i`\ 25.5 IN(547 M ) 25.61N. (647 mm) w (647 ) , 11.5IN. , , c (292 mm) \ � , l ,' 1 1 35 IN, 1 (889nm) '122 IN 1 )4'� (3055 mm) °0'� ,i b� ooeva 35 IN. 1889mm) ` �,1 pX10 pa6,l {y 1 i 1 Fryer Specifications: A • Vat Size: Length: 122 in. (3098 mm) Width:31.3 in.(795 mm) . Depth: 11 in. (279 mm) \ • BTU Rating:360k \ ' \ • Vat Oil Capacity: \ 35 IN. ` 1250 lb(566.9 kg) , (589^all) \ 35 iN, (889 mm) \ i ( 21N. _.__—.-- —C I... (51 mm) J 2IN. L (51 mm) R. 11111111111111111111111111111111111111111111 1 m 1 11 1 FIGURE 4-80 FIGURE 4-81 . ... ... ... .......„........ . , .... R-702 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-41 SPECIFIC APPLICATION BY MODEL(Continued) Garland Electric Dual-Side Clamshell Broiler-Model CXBE12 Nozzle Quantity/Type: One 1N nozzle Nozzle Height: 12 in. (304.8 mm)to 15 in. (381 mm) above lower cooking surface Nozzle Location: 1 in. (26 mm) from side of appliance at 12 in. (304.8 mm) up 1 in. (26 mm)to 3 in. (76 mm)from side of appliance at 15 in. (381 mm) up See Figure 4-82 Nozzle Aiming Point:Center of lower cooking surface .1.\0'1 1 Li 1, 1 . n ' 1 NOZZLE CENTERED WITH LOWER COOKING SURFACE .-- IIIIIIIII Ev.i.r.--911 NOZZLE AIMED TO CENTER OF LOWER ot COOKING SURFACE Ita 12 IN.TO 15 IN.(304.8 roro co 381 rom)ABOVE LOWER COOKING SURFACE umummmos , Wirligli • I IN,(26 mm)FROM SIDE OF APPLIANCE AT 12 IN. ...•... (04.8 roll)UP;1 IN.TO 3 It,/(26 mm to 76 rnm)FROM SIDE OF APPUANCE AT 15 IN.(381 mm)UP • m c..--- • TOP COOKING SURFACE: 10.2 IN.x 22,4 IN . (259 mm x US gat) BOTTOM COOKING SURFACE: 10(3 IN.It 22.2 IN ---101 r.---- (274 min x 584 mrn1 IL' ,11 TOTAL LOAD. 16 kW I 1 o. FIGURE 4-82 ''V( 10..01064,441*16,110NOIRAU.N.M1 IMAIMIefrIaY.s.i.ENN, SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-42 REV. 11 2014-SEP-01 SPECIFIC APPLICATION BY MODEL(Continued) DUKE Chain Broiler With or Without Catalyst View DUKE Chain Broiler-Model FBB-High Proximity Exhaust Deflector Size - 6.25 in. (159 mm) x 26.75 in. DUKE Chain Broiler With or Without Catalyst View: (679 mm); • Nozzle Quantity/Type:Two 245 nozzles l'•• Nozzle Quantity/Type:One 290 nozzle •Nozzle Height: 15 to 20 in. (381 to 508 mm) above top of Nozzle Height: Sin,to 15 in. (203 mm to 381 mm)above top P•• appliance of applianoe. Nozzle Location: Centered 6 1/2 in. (165 mm) back trorr • Nozzle Location: 6.5 in. (165 mm) from front or back edge °• of hazard front feed edge of appliance. Nozzle must be oriented to spray onto impedance plate. First nozzle positioned 17.25 in. (438 mm) • Nozzle Aiming Point:Aimed at center of impedance plate from right side of broiler(facing broiler) Second nozzle positioned 15 in. (381 mm) from first nozzle 1.--zoo Nozzle must be oriented to spray onto NOZZLE impedance plate. • Nozzle Aiming Point:Aimed at at center of impedance plate / LOW SIDE / OF PLATE Note: If the deflector or flue gas diverter is rotated 180 degrees. IMPEDANCE / the nozzles must also rotate to discharge into the opening. PLATE, / si. .-6 1/21N. aft ,,_Is N, ..._17 1441N.,(165mm) 6 1/2 8)L81F56 mrt„ MI"Ifni OW Irrn) FROPI EDGE )ANCE-1--100 i 0 !COO 41.11111111mmil 11111111 P. MAT IMPEDANCE PLATE IS ANGLED TOWARD (SEE SIDE VIEW) PRODUCT-, OUTPUT , 0 00 t 00 ""--P"FRATED 1ITT—f—T-000000001 ° I I 0000000 I 0000000 GRILL CENTER DUCT L Side View I F. ,pat?FrucT 1 COVCO ......290 NOZZLE TOP VIEW 24,5 Nozzx FLUE OAS ...,......./OrVESTER 15-20 IN. -- - ---- -\ -.1- (381 508 mm, 6 1121N(185 tnm) ' c' 8 IN.(203 Mrn)to PROM EDGE OF ,,,- .--. \ 1i8 INviriEtriar nHl APPUANCE THAT -1 4- IN 11111.1110{1=1.1 4 IMPEDANCE PLATE tS ANGLED TOWARD PRODUCT 1 I ..„....INPUT PRODUCT ,- OUTPUT BACK FRONT C01306,8 SIDE VIEW X7.gla FIGURE 4-84 Front View(Feed Side) FIGURE 4-83 ._,,._..................________......_..... _. _ .. . R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-43 SPECIFIC APPLICATION BY MODEL(Continued) DUKE Electric Broiler-Model FBB-High Proximity DUKE Electric Broiler-Model FBB-High Proximity DUKE Electric Broiler with or without Catalyst View DUKE Electric Broiler without Catalyst View Nozzle Quantity/Type:Two 1N nozzles i.Nozzle Quantity/Type: One 290 nozzle Nozzle Height: 18 in. (457 mm) *Nozzle Height: 15 to 20 in. (381 to 508 mm) Nozzle Location: 6.5 in. (165 mm)from edge of appliance that Nozzle Location: 6.5 in, (165 mm)from edge of appliance that . impedance plate is angled toward i• impedance plate is angled toward First nozzle positioned 5 in. (127 mm) to left See Figure 4-86 of opening centerline Nozzle Aiming Point: Aimed at center of opening Second nozzle positioned 5 in. (127 mm) to \ right of opening centerline See Figure 4-85 i• t 15 IN.TO NOZZLE1N,(SEHIrGi..11. 508 mm) Nozzle Aiming Point:Aimed at center of opening 6 1/2 IN.(165 rnm) T FROM EDGE OP-4. APPLIANCE THAT dmill (2)-1 N NOZZLE-, $. IMPEDANCE PLATE IS ANGLED \ t TOWARD .A..,-PRODUCT 18 IN.(457 mm) PRODUCT :--1 .001.111111" INPUT 6 1/2 IN.065 mrn)wi NOZZLE HEIGHT OUTPUT FROM EDGE OF 'im APPLIANCE THAT mild11111 5, IMPEDANCE ,,..-•PRODUCT 9 IN.(229ElEmmV1U)ST728°.P75ENNINIC"366(3679 immF)RONT 5. PLATE IS ANGLED SACK TOWARD 00.111111111h- INPUT PRODUCT OUTPUT : SACK FRONT SIDE VIEW Gown 6 1/2 IN.(1155 mm)FROM 1 1 EDGE OF APPLIANCE • .THAT IMPEDANCE PLATE PERFORATED IS ANGLED TOWARD —, 0 0 0 O 0 0 GRILL 1* -1. 10 IN. 2.34.mm) CENTERED (SEE SIDE VIEW) t 000 000 6 1/2 IN.(165 mm)FROM 1 ON OPENING EDGE OF APPLIANCE g--1- g CENTER 0 THAT IMPEDANCE PLATE 0-PERFORATED PRODUCT--4. 1111111111 CE IS ANGLED TOWARD — 0 0 0 0 0 0 GRILL OUTPUT DUCT (SEE SIDE VIEW) t 00 0000 0000000 0000000 PRODUCT-0. ° inin 0. CENTER OUTPUT 0 0 DUCT 000 000 =JO .0-.PRODUCT 000 000 INPUT TOP VIEW 41.--PRODUCT FIGURE 4-86 <,. INPUT COW TOP VIEW FIGURE 4-85 I SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 I: PAGE 4-44 REV. 11 2014-SEP-01 --, SPECIFIC APPLICATION BY MODEL(Continued) Nieco Broiler Model 940, 962 or 960 With Catalytic DUKE Electric Broiler-Model FBB-Low Proximity Converter Protection DUKE Electric Broiler with or without Catalyst View Note: Niece broilers without catalytic converters use standard chain broiler protection options. Nozzle Quantity/Type: Two 245 nozzles Certain models of the Niece broiler(Models 940.962, and 960) Nozzle Height: 8 in. (203 mm)to 15 in,(381 mm) are equipped with a catalytic converter to comply with new clean Nozzle Location: 6.5 in. (165 mm)from edge of appliance that air laws. Because of the converter, it is necessary to protect impedance plate is angled toward these broilers in a special way. The guidelines for protecting these broilers are as follows: First nozzle positioned 17.5 in. (444 mm) from right side of broiler(facing broiler) -The maximum internal broiling area is 29 in, x 23.5 in. 37 Second nozzle positioned 15 in. (381 mm) (7 mm x 596 mm). from first nozzle -An R-102 3-gallon system with a maximum of six flow See Figure 4-87 numbers, must be used for protection of each broiler, includ- ing plenum and duct. Nozzle Aiming Point: Aimed at center of opening -Each individual broiler must be protected with a minimum of (2)-245 NOZZLE-\\ tWO 1N nozzles. The nozzles must be located as shown in Figure 4-88. 8 IN.(203 mm)TO is IN.(381 mm) -The broiler must be fitted with two 1 in. (25 mm) high agent 8 1/2 IN.(165 mmiH NOZZLE HEIGHT FROM EDGE OF ..- bafflers on the angled surface of the broiler. If these have APPLIANCE THAT wild t I. IMPEDANCE not been completed by the equipment supplier,they must be PLATE IS ANGLED added in the field. TOWARD PRODUCT PRODUCT : iiiii INPUT 30' OUTPUT (2)1N NI')711 ES --*- SACK FRONT SIDE VIEW 00336$ 0 0 14.25*1 IN, (382 mm*25 rrtrn) 151N. 17112 IN. (381 mm (444 mm -a alliri aIIIIIIIIIIIIIIIIIIIIem 81/2 IN.(165 mm)FROM I =----------____ EDGE Of APPLIANCE -.2- LIIIIIIIIIII * THAT IMPEDANCE PLATE PERFORATED IS ANGLED TOWARD 00100i00 GRILL _ ‘,. .ork (SEE SIDE VIEW) 12 IN TO 13 IN. ------'-'--1•) 0 01 0 0 0 0 f308 mm to 330 nn) 1 r17--__ Illi PRODUCT 0 CENTER <I OUTPUT 0 0 DUCT sI--- -- • - 3-0000000 ___-_ 0000000 . ! , PRODUCT LOCATE NOZZLES 2 13/16 IN.(71 mm)ON mem INPUT EACH SIDE Of BROILER CENTER LINE TOP VIEW FIGURE 4-87 1.11M111 14,26*1 IN 111111111111111111111111111111111111111111111111 (3e2 mm*25 mm MMONIMMU i iiMaili Illr-.1 „I „' .."---11111111111 , :-.: ie...... ri ,,,_ , col, FIGURE 4-88 I R-102 Restaurant Fire Suppression Manual SECTION 4 -SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-45 SPECIFIC APPLICATION BY MODEL(Continued) Nieco Broiler-Model 950, 960, 980, 1424 Nieco Broiler-Model 9015(With or Without Catalytic • Nozzle Quantity/Type:One 2W nozzle Converter) • Nozzle Height: 20 in. (508 mm) above top of appliance. See • Nozzle Quantity/Type:Two 2W nozzles Figure 4-89a. • Nozzle Height: 20 in. (508 mm)above top of appliance. See • Nozzle Location:6 1/2 in. (165 mm) back from front edge of Figure 4-90. appliance. See Figure 4-89a. • Nozzle Location for Large Chamber: 6 1/2 in. (165 mm) • Nozzle Aiming Point:Aimed at center of opening.See Figure back from front edge of appliance. See Figure 4-90. 4-89a. • Nozzle Location for Small Chamber: Nozzle to be located 6 1/2 in, (165 mm) back from front edge of appliance and Nieco Broiler-Model 950, 960, 980, 1424(with Catalytic 12 in. (305 mm)over from large chamber nozzle. Converter) • Nozzle Aiming Point for Large Chamber:Aimed at center of • Nozzle Quantity/type:Two 2W nozzles opening. See Figure 4-90. • Nozzle Height: 20 in. (508 mm) above top of appliance. See • Nozzle Aiming Point for Small Chamber: Nozzle to be aimed Figure 4-89b. 12 in.(305 mm)over from large chamber nozzle aiming point, • Nozzle Location:6 1/2 in. (165 mm) back from front edge of appliance. See Figure 4-89b. if • Nozzle Aiming Point:Aimed at center of opening. See Figure (t. / 4-89b-Side View. , L ..i—6 112 iN. • Nozzle Aiming Point:Aimed at point 3 in. (76 mm)each side ___ r____ 0155 rnm) _ of center.See Figure 4-89b-Front View. ! CATALYTIC CONVERTER 1 / / (1 65 mrn) — (165 rnm) SIDE VIEW 1 (2)2W NO771 PS t 12 IN. t SIDE VIEW SIDE VIEW 20 IN. (508 mm) --..— -----------..--- 2W NOZZLE 2W NOZZLE + 3 IN, 3 IN ciG mcn .00..040(76 rnm) 201IN ) CENTERLINE OF 20 . (508 mm) LARGE OPENING (508 rnm) FRONT VIEW FIGURE 4-90 amo•c, CENTERLINE OF ----* CENTERLINE OF LARGE OPENING LARGE OPENING FRONT VIEW FRONT VIEW FIGURE 4-89a FIGURE 4-89b comas corz,r ri( - ra Nr.anyr......extata..W.,101+30H,FF.,. .w0., .•. ......' SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual _ UL EX3470 ULC EX3470 PAGE 4-46 REV. 11 2014-SEP-41 SPECIFIC APPLICATION BY MODEL(Continued) Nieco Broiler-Model 9025 (With or Without Catalytic Nieco Broiler-Model MPB94 and MPB84-High Proximity Converter) (With or Without Catalytic Converters) • Nozzle Quantity/Type:Two 2W nozzles • Nozzle Quantity/Type:One 2W nozzle • Nozzle Height: 20 1/2 in. (520 mm) above top of appliance. • Nozzle Height; 20 in. (508 mm) above top of converter. See See Figure 4-91. Figure 4-92. • Nozzle Location: 6 1/2 in. (165 mm) back from front edge of • Nozzle Location: Centered 6 1/2 in. (165 mm)back from any appliance. See Figure 4-91. edge of the appliance. See Figure 4-92. • Nozzle Aiming Point:Aimed at center of each opening. See • Nozzle Aiming Point:Aimed at center of opening.See Figure Figure 4-91. 4-92. t TOP VIEW 6 1.2 IN.(166 mm)TYR / ANY SIDE i 1 / I / / (165 mm; { SIDE VIEW 00122 (2)2W NOZZLES SIDE VIEWS 2W NOZZLE \ f / 1 18.20 1/2 IN. (6765 m) V / V / I (457-52c mm) TYP,ANY I \ I (520 p8 IN. I SIDE \\ \\ / -I.--- ',----1----', —1. — \ / -' - 1 / i I CENTERLINE CENTERLINE OF OPENING OF OPENING FRONT VIEW FIGURE 4-91 xrsz3 FIGURE 4-92 c R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN 1 . UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-47 SPECIFIC APPLICATION BY MODEL(Continued) Nieco Broiler-Model MPB94- Low Proximity(With or '. Without Catalytic Converter) Nieco Broiler-Model MPB84-Low Proximity(With / Catalytic Converter) Nozzle Quantity/Type: Two 245 nozzles Nozzle Quantity/Type:Two 245 nozzles Nozzle Height: 8 in. to 15 in. (203 mm to 381 mm) measured Nozzle Height: 8 in. to 15 in. (203 mm to 381 mm) measured from top of converter from top of converter Nozzle Location: 6.5 in. (165 mm) from front or back edge of Nozzle Location: 6.5 in. (165 mm) from front or back edge of hazard. hazard. First nozzle positioned 7.5 in. (190 mm) to First nozzle positioned 7.5 in. (190 mm) to the right from center of hazard. the right from center of hazard. Second nozzle positioned 7.5 in. (190 mm)to Second nozzle positioned 7.5 in.(190 mm)to the left from center of hazard. the left from center of hazard. See Figure 4-93. See Figure 4-94. Nozzle Aiming Point: Aimed at opening on respective center Nozzle Aiming Point: Aimed at opening on respective center lines lines BACK FRONT ,.....„;,.AIM POINT BACK FRONT AIM POINT 245 NOZZLE ..,-.'".. 245 NOZZLE 7 1/2 IN. ( mm) 7 112 IN. 190 (191 mm 7 v2IN. ce (190 rnm' 245 NOZZLE 7 1/2 IN. 091 rnal 245 NOZZLE _ 6 12 IN, (165 mm) ..-- ..--.---AIM POINT 6 1/21N. ,....... (166 mm) 1.— AIM POINT =CV WOW CL c... TOP VIEW TOP VIEW 245 NOZZLE—\\ 245 NOZZLE \ \ \ 6 1/2IN,(166 mm) 6 112 IN(165 mm)-...1 ...-•• PRODUCT PRODUCT PRODUCT PRODUCT OUTPUT -...„ IN 'T OUTPUT IN .....„ FRONT FRONT BACK BACK SIDE VIEW 000098 SIDE VIEW CMOS' FIGUREFIGURE 4-94 4-93 I .4400,.....................0.,...............,.............,.....,„„.......,.......—..,........„,...,,„,„,—„,-,.......—........... . ,. „ SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-48 REV. 11 2014-SEP-01 SPECIFIC APPLICATION BY MODEL(Continued) Nieco Broiler-Model MPB84 and MPB94- High Proximity Nieco Broiler-Model MPB84 and MPB94-Low Proximity (With Perforated Cap OR with Catalytic Converter and (With Perforated Cap OR with Catalytic Converter and Chimney) Chimney) Nozzle Quantity/Type: Two 1N nozzles Nozzle Quantity/Type: Two 245 nozzles Nozzle Height: 18 in. (457 mm)to 20 in. (508 mm) Nozzle Height: 8 in. (203 mm)to 15 in. (381 mm) Nozzle Location: 6.5 in. (165 mm) from front or back edge of Nozzle Location: 6.5 (165 mm) from front or back edge of hazard hazard First nozzle positioned 5 in, (127 mm) to left First nozzle positioned 7.5 in. (190 mm)to the of opening centerline right of hazard centerline Second nozzle positioned 5 in. (127 mm) to Second nozzle positioned 7.5 in. (190 mm)to right of opening centerline the left of hazard centerline See Figure 4-95 See Figure 4-96 Nozzle Aiming Point: Aimed at center of opening Nozzle Aiming Point:Aimed at center of opening 12/-1N NOZZ-E -- (2)-245 NO77I E.—\ WITH OR WITHOUT WITH OR WITHOUT CHIMNEY "T CHIMNEY --T 6 1/2 IN.(165 mrn) \ 18 IN.(467 mm)TO 8 1/2 IN,(165 rnm) \ 8 IN(293 rnrn)TO FROM FRONT 20 IN.(508 rnm) FROM FRONT 15 IN.(381 Min) OR BACK EDGE — NO771 F HEIGHT OR BACK EDGE _ N077,F HEIGHT i PRODUCT PRODUCT PRODUCT PRODUCT OUTPUT INPUT OUTPUT iNP',JT BACK FRONT BACK FRONT SIDE VIEW C089(i9 SIDE VIEW 0C4169 (2)-1N NOZZLE I (2)-245 NOZZIE r---6• 00 i FE,-. 0 0 I OdP.'.."... ••••''octP . . . . AIM ....0",,[DINT - • 0.0- hz_t,,...0 INT I 5 IN.(127 rnm) 7 V2 IN (180 mm) I c'f:P.I'cAD° o4it,.,4c, L 5 IN.(127 min) ° . •°o°cP I 7 irz IN.oso rrr) dc;F,..•.o oo I -o- NNANa0615.47"0"4-••• QQ;P ';'44' AIM 6 1/211.07/3 04 SACK EDGE 0 00 rta BACK EDGE 0 0 ••,0:00 rINT :,,00 . .. BACK FRONT BACK FRONT west 00637D C. c. TOP VIEW TOP VIEW FIGURE 4-95 FIGURE 4-96 R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-49 SPECIFIC APPLICATION BY MODEL(Continued) Nieco Broiler-Model JF94E Electric Broiler-High *Nieco Broiler-Model JF94E Electric Broiler-Low Proximity(With Catalyst) Proximity(With Catalyst) Nozzle Quantity/Type:Two 230 nozzles Nozzle Quantity/Type:Two 245 nmiles Nozzle Height: 20 in. (508 mm) Nozzle Height:8 in.(203 mm)to 15 in. (381 mm) Nozzle Location: 6 1/2 in.(165 mm)from front or back edge of Nozzle Location: 6 1/2 in. (165 mm)from front or back edge of hazard hazard Nozzles positioned 15 in. (381 mm) apart Nozzles positioned 15 in. (381 mm)apart See Figure 4-97 See Figure 4-98 Nozzle Aiming Point:Center of catalyst Nozzle Aiming Point: Center of catalyst (2).230 NOZZLE—\Ns\ (2) TA •245 NO N. "T 20 IN.(508 mm) 13 IN(208 mil). 6 1/2 IN (165 mm) 4'0111'iEt""Gar FROM EIXIE H' NOZZLE HEIGHT 61/21N.OM mm) PROM MGE l'im PRODUCT PRODUCT PRODUCT PRODUCT OUTPUT INPUT OUTPUT INPUT ..e* BACK FRONT SACK FRONT 00604 (moo SIDE VIEW SIDE VIEW (2)-230 NOZZLE (2)-245 NO27 g AIM CENTER AIM CENTER BACK FRONT 51,50,,_jor.,4 FRONT SAO< C 8 IN MF"-..-:'411111--f.; c 8 IN I to- ass , (203 mm) t MVO I- (203 mm) 4 15 IN. '15 IN. (sr 111171) ' I.i •-•'.1. (361 mm) 146—t!--1 rnnl i 81N 6 1/2 IN.(166 rim) IMMilir,P7` ,,,,. .''' CL (23.3rnm) FROM EDGE S.-`..--: 116 AIM CENTER 6 112 IN.ties nitro rejnyr,4,3 .. SIN.( ) FROM Frexv •,:-7" 4, AIM CENTER OC#AV 0064.3 s c. c.. TOP VIEW TOP VIEW FIGURE 4-97 , FIGURE 4-98 ,,, ,A-040(0.1.424WMilo..1....144.4l........I1.4.0.140•44.41.4440010ANONNAVA•sr.kivi,..00.0110.0401000.4”Ortrneporaanatfew.roned. 0.1.4"OA I, PIO IIIPI4 SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-50 REV. 11 2014-SEP-01 SPECIFIC APPLICATION BY MODEL(Continued) w Nieco Jet Flow Automatic Chain Broilers-Models JF62, t• Nieco Jet Flow Automatic Chain Broilers-Models JF64G, JF63,JF92,JF93,JF143 (With or Without Catalyst) JF84G,JF94G-High Proximity(With or Without Catalyst) Nozzle Quantity/Type: One 245 nozzle Nozzle Quantityfrype:Two 230 nozzles Nozzle Height: 20 in. (508 mm)to 25 in.(635 mm) Nozzle Height: 20 in. (508 mm) Nozzle Location: Centered above the catalyst to 5 in.(127 mm) Nozzle Location: 6.5 in. (165 mm) from front or back edge of forward of catalyst front edge hazard See Figure 4-99a Nozzles positioned 15 in. (381 mm)apart Nozzle Aiming Point: Center of catalyst See Figure 4-99b Nozzle Aiming Point: Center of catalyst front to back; 6 in. ALLOWABlf.NOZZIE. LOCATION IN GRID (152 mm)in from each side of catalyst CENTER UNE CATALYSTE z XHAUST 1 15 IN.(381 mm.) OPENING SPACING CENTERED AIM AT CENTER AIMED 6 IN. OVER CATALYST / AIMED 6 IN. (152 mm) ...... 2...,,,,...m...,,,,m (152 r•rn) FROM SIOE OF FROM SIDE OF 25 IN 14 1-e--- 51N. CATALYST CATALYST (635 rrn) 2V IN. i127 frrn) i i •tf .11111111111111111K EXHAUST OPENING' ,. c.1 23.0 IN.(564 mm)wioe x tir-. 1SEigiEggiliii.i 14.2 IN,(350 ma)LONG BACK FRONT il=lt= 71 ...—„. —... .....____ ...--- BROILER CHAMBER' ;601.Iiiminim.Am` 1 piEs( II C06910 28. IN.(724 mm)WIDE x 1. ..........";s17. 1.. .-.,.. I 116,0.- 20.0 IN.(50e mm)LONG ..-----.a....1.:.=-,---,......-..;-;5.,:-.1 -,...—.... ., ow AN Row- cerm,UNE 1 I i /CENTER UNE I 2../.. SAC'H 061111 FRONT — ALLOWABLE NOZZLE iL 1 LOCATION UNE AIMED TO CENTER .."1 i 20 IN.(508 mm) FIGURE 4-99a OF CATALYST / I I ;NO72LE HEIGHT * 1 111111111111••••••••• ilm... i. .1 6.5 IN.FRON(4166 mm)EDG --- 111111.11- II' 11- II-- OF ARPUANCE rk t meg " go is is . . 13 el WI ! 11 i 1 .. 4. FIGURE 4-99b R-702 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-51 SPECIFIC APPLICATION BY MODEL(Continued) 0.Bakers Pride Broiler-Models CH6, CH8,CH10, XX6, XX8, Maglkitoh'n Gas Radiant Char-Broiler with Smoker Box XX10(With Wood Smoker Box and Chip Holders) -Models FM-RMB-660, FM-RMB-648, FM-RMB-636 (With Wood Smoker Box and Chip Holders) Nozzle Quantity/Type: Two 3N nozzles Nozzle Height: 25 in. (635 mm)to 40 in. (1016 mm) above the Nozzle Quantity/Type:Three 3N nozzles hazard surface Nozzle Height: 25 in. (635 mm)to 40 in. (1016 mm) above the broiler surface Nozzle Location: Each nozzle is to protect half of the cooking area and located within 1 in. (25 mm) of the Nozzle Location: All three nozzles are to be centered front to center of the respective cooking area,aimed back above the broiling surface. The middle at the center of that hazard area nozzle is to be centered left to right above the broiling surface. The remaining two nozzles See Figure 4-100 are to be located 9 in. (229 mm) inside the Note: Smoker Box and Chip Holders cannot exceed logs 4 in. broiler sides. (101 mm) in diameter and a maximum allowable wood depth of 4 in. (101 mm). See Figure 4-101 3N NO77 FS Note: Smoker Box and Chip Holders cannot exceed logs 4 in. (101 mm) in diameter and a maximum allowable wood depth of 4 in. (101 mm). CENTER LINE OF RESECTIVE cOOsUNG JEA NO721E HEIGHT 9 IN. IN ANY DIRECTIONr 25 IN-40 IN. (229 ram) , (636 mm 1016 mm) 9 IN. (229 mm) CENTERED CENTER OF masa CENTER OF BROILER BROILER 1/2 OE 1/2 OF • 26 TO 40 IN. COOKING I .1—COOKING ":441111 (635 lo 1016 mm) AREA AREA iN.(25 mm) MAXIMUM IN.(25 rrer) MAXIMUM FRONT COOKING AREA FIGURE 4-101 CENTER OF RESPECTIVE COOKING AREA 0C4.93 FIGURE 4-100 ?e,ii.k.V.W...1!Nen,Ains,doi441:1KMAIWallge+4,14440110.4......e. ' MI.4.00.1...40:41000....................,.....WWII..........0....abe........M.V.Warltliay.1.04.1aaVeeadaWraf•IfIFIIIFIRMIINVIT.^' SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-52 REV. 11 2014-SEP-01 . . SPECIFIC APPLICATION BY MODEL(Continued) Marshall Air-Model 2001BK Multi-Chamber Broiler Marshall Air Electric Broiler-Model FR14B AutoBroll • Nozzle Quantity/Type:Two 1W nozzles Nozzle Quantity/Type:One 260 Nozzle • Nozzle Location: Front nozzle tip must be located 14 in. Nozzle Height: 15-20 in. (381 -508 mm)above the (355 mm) directly above the appliance, aligned with the front top of the broiler face and centerline of the catalytic converter.The aim point is Nozzle Location: The nozzle must be centered above the 4 in. (101 mm)forward of the front edge of the converter on front edge of the broiler the centerline, Nozzle Aiming Point: Aimed at the center of the exhaust The rear nozzle tip is a mirror image of the front. The rear opening of the broiler. See Figure nozzle is located 14 in. (355 mm) vertically above the appli- 4-103. ance, aligned with the "rear" face and centerline of the cata- lytic converter. The aim point is 4 in. (101 mm) behind the • I 2425 IN. 14,50 IN "rear" edge of the converter on the centerline. See Figure 1 1 (615 rnm) (268 rnm) 4-102. le-.2.3 IN. ' (361-SOB rnm) \ ,,,,, 24 IN. • System Limitation: Maximum of five flows for a 3.0 gallon 34.ES IN. (609 cm) .........- .X...- i . '',...,.... system: Remaining flow points available may be used to (MI Mtn) , ,.. V . protect other hazards. CENTERED ON CONVERTER <".....'---<.''i I I CONVERTER i TWO 1W NOZZLES i A I 4.9 IN, I (1219 mm) \ I i 1 , I LI I -IIIIIIIMI • I , Nimimmona_M 11 1 ,_ .._.....2_,......... 0411 , =Mit . ...... ON I iiimmil --- I 1 ..............issuism — FIGURE 4-103 FRONT VIEW ,:4717 NOZZLE ALIGNED WITH FRONT OF CONVERTER Grease Grabber-80Th"Two Stage Filtration System NOZZLE ALIGNED WITH NOZZLE ALIGNED WITH BACK FRONT OF CONVERTER. OF CONVERTER,AIMED The Grease Grabber-80 Two Stage Filtration System consists of AIMED 4 IN,(101 mm)BACK 4 IN.(101 mrn)FORWARD two components:The primary fitter(The Grease-X Tractor) and J. the secondary fitter(The Grease Grabber-80). lw lw NOZZLE mozzLE The protection required for this application is the same as the 14 N. a IN 14 IN standard plenum/fitter protection: One 1N nozzle protecting 10 -- (355 (355 rnrr) (3.0 m) linear feet of plenum length by 4 ft (1.2 m) of plenum I., IT 1... nn) (101 rnm) 4 ii chamber depth(width),positioned 2 in.to 4 in.(51 mm to 102 mm) from peak of secondary fitter. See Figure 4-104. .• —/"E" FT.(1.2 R1) NMI law._ 4MAXIMUM III ,I ;SECONDARY FILTER i 1 IIMMOINIMEMMIIIIII 1N 026.1513 )1( t'` ,0 Zn.E SIDE VIEW FIGURE 4-102 PRIMARY FILTF_FI I , ., ($1-102 mrn) -I NOTE; TWO NOZZLES MUST BE UTLIZED FOR V-SANK FILTER ARRANGEMENT. FIGURE 4-104 c065.'s R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN , UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-53 OVERLAPPING NOZZLE COVERAGE • For appliance hazard surfaces with listed protection exceed- Overlapping Coverage-Option 1 ing the standard hazard zone of 28 in. (711 mm) in depth, the For each group of protected appliances under a common hazard surface(s) must be aligned with the back edge of the hood(s), the overlapping nozzles must be located from right hazard zone, with the front edge overhanging the front edge to left so that each end nozzle is located a maximum of 6 in. of the zone.See Appliance Chart,Table 4-1. (152 mm)inside the outside edge of the cooking hazard of each * For appliance hazard surfaces that exceed the listed protec- end appliance, and the inside overlapping nozzles must be tion sizes,multiple zones must be utilized.Align entire hazard located between the two end nozzles at a maximum spacing of surface area within the multiple zones. I 12 in. (304 mm). .• All hood,duct,individual appliance,piping,and flow limitations are as specified in the R-102 Design, Installation, Recharge Hazard Zone and Maintenance Manual (Part No.418087). The hazard zone is defined as a theoretical,flat and level, rect- . All appliance protection currently listed in the R-102 Design angular surface, that includes all of the cooking hazards of the Manual (Part No. 418087) is also approved protection. Zone protected appliances under a common hood(s).The purpose of protection can be considered optional protection. the hazard zone is to provide a means of locating the appliances and the overlapping nozzles, as well as aiming the overlapping TABLE 4-1 nozzles. The hazard zone measures 28 in. (711 mm) deep by the length of the cooking hazard(s).The centerline of the hazard Overlapping Nozzle Coverage(Zone Protection) zone must bisect the 28 in. (711 mm) depth (from front to back) Appliance Type Maximum Cooking Hazard and run from right-to-left for the full width of the hazard zone. Fryer 34 in. (863 mm)Deep x 5.8 ft2 (0.5 m2) Griddle 30 in. (762 mm)Deep x Unlimited Length Overlapping Nozzle Appliance Protection Overlapping Nozzle Appliance Protection is defined as protec- Range 28 in. (711 mm)Deep x Unlimited Length tion of cooking appliances by nozzles spaced uniformly at Wok, Maximum 30 in. (762 mm)Diameter x 8 in. uniform elevations under a common hood(s). Overlapping (203 mm) Deep protection of appliances is continuous for the full length of the Wok, Minimum 11 in. (279 mm) Diameter x 3 in. hood or divided when group(s) of protected appliances are (76 mm) Deep -- separated by counters or appliances not requiring protection. Braising Pan/Tilt 34 in. (863 mm)Deep x Unlimited ' Full hood continuous protection is defined as overlapping Skillet Length nozzle appliance protection that covers the appliance line-up Lava Rock 32 in. (812 mm) Deep x Unlimited located under the total hood length. Ail appliances requiring Char-Broiler Length protection are the appliances under the hood that can be an igni- Charcoal Broiler 32 in. (813 mm) Deep x Unlimited Length tion source of grease in the hood, grease removal device or the (4 in.(102 mm)Maximum Fuel Depth) duct. Mesquite Wood 32 in. (812 mm) Deep x Unlimited Length Broiler (12 in. (304 mm) Maximum Fuel Depth) Group protection is defined as overlapping nozzle appliance protection that protects individual hazard zones located under a Gas Radiant 36 in. (914 mm) Deep x Unlimited Char-Broiler Length common hood.These"groups"of appliances may be separated by appliances not requiring protection,such as steam equipment Electric Char-Broiler 34 in. (863 mm) Deep x 20 in. (508 mm) or work tables, or by dedicated appliance protection, such as •See Figure 4-105 for nozzle iocation salamander broilers. • See Figure 4-108 (full hood continuous protection) and Figure I ! . 4-109(multiple group protection). 0-6 IN.(0-132 mcn) COVER MUST NOT , I !i Dedicated Nozzle Appliance Protection INTERFERE WITH i i EDGE OF Appliance protection using dedicated nozzle coverage is defined DISCHARGE as protection of cooking appliances with enclosed cooking PATTERN 1 : 40-45 IN (10i6-i 43 rrvn) 1 hazards, such as upright broilers, which cannot be protected , f with overlapping nozzles and therefore must be protected with i nozzles dedicated to the appliance. i ,t General Design Limitations / ZONE • Maximum depth of zone is 28 in. (711 mm). r ,.( i,zvioeRoa;S14iti.'a:ai.VP4: comer • The 245 nozzle is the only approved nozzle for overlapping (zone) protection. • Nozzle must be located 0 in.to 6 in.(0 mm to 152 mm)forward ZONE CENTER LINE zone centerline, aimed back at the zone centerline. FIGURE 4-105 • Nozzles must be spaced a maximum of 6 in. (152 mm) from each end of hazard and then a maximum of 12 in. (304 mm) on center for the remaining overlapping nozzles until the complete hazard is covered. • SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-54 REV. 11 2014-SEP-01 OVERLAPPING NOZZLE COVERAGE(Continued) 4. The overlapping appliance nozzles must be located 0 in.to 6 in. (0 mm to 152 mm)forward of the centerline or aimline Overlapping Appliance Nozzle and Hazard Zone Locations of the selected hazard zone.See Figure 4-107. 1. All overlapping appliance nozzles must be the 245 nozzle and must be located under a common hood at the same 245 NOZZLE-NOZZLE MUST BE AIMED STRAIGHT height above the hazard zone, in a straight line from right oowN OR BACK AT CENTERLINE OF to left and aimed at the centerline of the hazard zone.The 44. HAZARD ZONE overlapping nozzle is used for both continuous overlapping and multiple group overlapping protection. 2. The hazard zone must be positioned (located) so that all appliance hazard surfaces are within the zone. For spoil- AS IN. ance hazard surfaces with listed protection exceeding the 6 IN. (1143 m) standard hazard zone size of 28 in.(711 mm) in depth (see Table 1), the hazard surface(s) must be aligned with the 40 back edge of the hazard zone,with the front edge overhang- (loie mm) ing the front of the zone. 3. The overlapping appliance nozzles must be located 40 in.to 45 in. (1016 mm to 1143 mm)above the top surface of the protected appliances. See Figure 4-107. FRONT BACK OF ZONE Exception No. 1: Nozzle dimensions for wok protection are OF ZONE CENTERLINE OF measured to bottom of wok. Exception No. 2: When using 28 IN. HAZARD ZONE (711 mrm overlapping appliance nozzles in areas where there is a ZONE back shelf, the nozzle cannot be positioned in the shaded area as shown in Figure 4-106. FIGURE 4-107 M6915 Also, back shelf must not extend more than 11 in. (279 mm) over the hazard zone and cannot be less than 20 in. (508 mm)above the hazard zone. See Figure 4-106. / OVERLAPPING NOZZLE(S) CANNOT BE POSITIONED 45 IN THIS SHADED AREA 4344 42 41 I z 40 6 5 4 3 2 CENTER UNE OF HAZARD ZONE BACK SHELF ,,IN.(279 mrn) MAXIMUM 20IN. (508 mm) MINIMUM E2222Z=1 4 28 IN.(711 mm) FIGURE 4-106 R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-55 7... OVERLAPPING NOZZLE COVERAGE (Continued) 2. When obstructions are located adjacent to appliance(s) Overlapping Appliance Nozzle and Hazard Zone Locations protected by overlapping nozzles,the overlapping appliance -Group Protection nozzle spacing must start with the appliance(s) adjacent to the obstruction. See Figure 4-110. 1. For each group of protected appliances under a common 121N. 1 12 IN. 12 IN. 12 IN. hood(s), the overlapping nozzles must be located from 8 IN, (304 awn)1(304 mrn) I 113.04 mrn) (304 mm)1 right to left so that each end nozzle is located a maximum (152 mrn) -.-.... 4 I. • S. holAx 4, pox, + max. + mAx..+4nAX.i4 "6-6 IN. (162 mrm of 6 in. (152 mm) inside the outside edge of the cooking MAX. hazard of each end appliance, and the inside overlapping nozzles must be located between the two end nozzles at a maximum spacing of 12 in. (304 mm). See Figures 4-108 7 .....OUTSIDE and 4-109. —11 EDGE OF COOKING HAZARD k _ 12 IN.(384 rnm)MAXIMUM SPACING(S)BETWEEN OVERLAPPING N0771 PS tt Y y if ' Ni....mIMIM iiar_ / \ / \ / \ i \ t I." HAZARD AREA -I 8 IN.--e. / / \ / ‘ 1 \ ___A,,..1 ‘ ,_ 6 IN, OBSTRUCTION (152 mm) I \ 1 \ / \ / \ / \ (152 min) FIGURE 4-110 MAXIMUM \ i \ / \/ \/ \ MAXIMUM 001713 FROM / V FROM EDGE OF I i( A '1 / EDGE OF 3. When an appliance requires dedicated protection with a COOKING / i 1 / 1 A i 1 \COOKING HAZARD / \ HAZARD protected area intended for overlapping appliance nozzle ____________ _. 111111 protection, the group protection option will be required for appliances on either side of the appliances using dedicated protection. Group protection using overlapping appliance nozzles must begin with the protected appliance(s)adjacent to the dedicated appliance protected.An overlapping appli- FULL HOOD CONTINUOUS APPLIANCE PROTECTION ance nozzle(s) must be positioned within 6 in. (152 mm) of the edge(s) of the appliance hazard surface area(s) adja- FIGURE 4-108 cent to the dedicated nozzle protection. See Figure 4-111, 0C3710 ."."'"'" ".1/...........• i , . • EDGE OF COOKING HAZARD 12 IN.(304 mrn) 6 IN,(152 rrn) MAXIMUM MAXIMUM I / N + / 4 \ + / \i 1 SIN. i 12 IN, + $ 12 IN. 1, 121N. t .... 8 IN. -0"" I/ 0 4 Id ^41- -0.1 •I ..-- 6 IN. (152 nutv,-40, IV4 r":) (504 mm)(304 mm) I 6 64. • MAX. MAX, t ma- - . MAX MAX' )4.-(152 mm) (152 rnmI I 12 IN. (152 mm) MAX. MAXIMUM I 004 mm) MAXIMUM EDGE-..... 6 IN.(162 mm)'-' 8 IN.(152 mm .....EDGE OF MAXIMUM 4116.••=1 MAXIMUM OF FROM \ / EDGE OF .. -- -- ' . — ...,I MAXIMUM FROM EDGE OF COOKING """ COOKING COOKING COOKING HAZARD HAZARD EDGE OF HAZARD COOKING HAZARD 4 _ GROUP APPLIANCE PROTECTION in / LI DEDICATED NOZZLE FIGURE 4.109 APPLIANCE 00172C FIGURE 4-111 003756 „-- SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-56 REV. 11 2014-SEP-01 OVERLAPPING NOZZLE COVERAGE(Continued) Overlapping Appliance Nozzle and Hazard Zone Locations -Group Protection (Continued) 4. On protected appliances, all hazard surfaces located in a group must be within 40-45 in. (1016-1143 mm) from the nozzle(s). Once that dimension is exceeded, a new group must be started See Figure 4-112, Note:The supply pipe feeding nozzle groups is to be at the same elevation.Adjust height for each group only by varying lengths of nozzle drops. 6 IN.(152 Mm) 6 IN.(152 rnm) MAXIMUM MAXIMUM t V i ; i A / Nopl=s NOZZLES t4 I 40 IN. 45 IN. (1 mm) (1143 mm) 016 4()IN. I 45 IN. (1016 mm) i 43 i(11 mrn) I / I r . 111111111....i. GROUP^A° 4"/'1 GROUPS- 1 FIGURE 4-112 Detection Requirements For Overlapping Appliance Protection When utilizing overlapping appliance protection, fusible link detectors must be installed on a maximum of 2 ft(0.6 m)centers, starting with detectors located in (under)the duct opening(s). Starting from the detector under the duct opening,add detectors on 2 ft(0.6 m)maximum spacing until the complete length of the plenum area is covered, from one end to the other.The location of the last detector on each end of the plenum must not exceed 2 ft(0.6 m) from end of plenum. Note: Standard detector coverage, as specified in Design Section," is acceptable when utilizing dedicated nozzle coverages. R-102 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 ...., . 2014•SEP-01 REV. 11 PAGE 4-57 OVERLAPPING NOZZLE COVERAGE(Continued) Overlapping Coverage-Option 2 General Design Limitations For each group of protected appliances under a common • If overlapping appliance protection is mixed with dedi- hood(s), the overlapping nozzles must be located from right cated appliance protection on the same pipe system, THE to left so that each end nozzle is located a maximum of 11.5 OVERLAPPING APPLIANCE PROTECTION PIPING in. (292 mm) inside the outside edge of the cooking hazard of REQUIREMENTS MUST BE FOLLOWED. each end appliance,and the inside overlapping nozzles must be • Overlapping protection requires the use of 3.0 gal (11.4 L) located between the two end nozzles at a maximum spacing of tank(s)and a maximum of six flows per tank. 25.5 in. (647 mm). • In installations using tanks only intended for overlapping Hazard Zone protection, a single Double Tank nitrogen expellant gas The hazard zone is defined as a theoretical, flat and level, rect- cartridge can be utilized with up to three 3.0 gal (11.4 L)tanks. angular surface, that includes all of the cooking hazards of the . In installations using both overlapping protection and conven- protected appliances under a common hood(s).The purpose of tonal non-overlapping protection (ex. hood/duct or dedicated the hazard zone is to provide a means of locating the appliances appliance protection),a single Double Tank nitrogen expellant and the overlapping nozzles, as well as aiming the overlapping gas cartridge can be utilized with up to three 3.0 gal (11.4 L) nozzles. The hazard zone measures 28 in. (711 mm) deep by tanks,as long as none of the 3.0 gal (11.4 L)tanks exceed a the length of the cooking hazard(s).The centerline of the hazard total flow output of more than six flows. zone must bisect the 28 in. (711 mm)depth (from front to back) and run from right-to-left for the full width of the hazard zone. • If more than six flows will be used in a conventional non-over- lapping tank, it cannot share the same cartridge as tanks Overlapping Nozzle Appliance Protection intended for overlapping protection. In this case,an additional Regulated Actuator Assembly with another expellant gas Overlapping Nozzle Appliance Protection is defined as protec- cartridge will be required. Ilan of cooking appliances by nozzles spaced uniformly at uniform elevations under a common hood(s). Overlapping • The 245 nozzle must be used for"end of zone"protection. protection of appliances is continuous for the full length of the • The 260 nozzle must be used for zone protection. hood or divided when group(s) of protected appliances are Maximum depth of zone is 28 in. (711 mm). separated by counters or appliances not requiring protection. • Refer to overlapping system piping requirements listed in Full hood continuous protection is defined as overlapping Table 4-2. nozzle appliance protection that covers the appliance line-up located under the total hood length. All appliances requiring • Nozzle must be located 0 in. to 12 in. (0 mm to 304 mm) protection are the appliances under the hood that can be an forward of zone centerline,aimed back at the zone centerline. ignition source of grease in the hood, grease removal device or . Nozzles must be spaced a maximum of 11.5 in. (292 mm) the duct. from each end of hazard and then a maximum of 25.5 in. (647 Group protection is defined as overlapping nozzle appliance mm)on center for the remaining overlapping nozzles until the protection that protects individual hazard zones located under a complete hazard is covered. common hood.These"groups"of appliances may be separated . For appliance hazard surfaces with listed protection exceed- by appliances not requiring protection,such as steam equipment ing the standard hazard zone of 28 in. (711 mm) in depth, the or work tables, or by dedicated appliance protection, such as hazard surface(s) must be aligned with the back edge of the salamander broilers, hazard zone, with the front edge overhanging the front edge See Figure 4-116 (full hood continuous protection) and Figure of the zone. See Appliance Chart,Table 4-1. 4-117(multiple group protection). • For appliance hazard surfaces that exceed the listed protec- tion sizes, multiple zones must be utilized.Align entire hazard Dedicated Nozzle Appliance Protection surface area within the multiple zones. Appliance protection using dedicated nozzle coverage is defined . All hood,duct,and individual appliance protection are as spec- as protection of cooking appliances with enclosed cooking ified in the R-102 Design, Installation, Recharge and Mainten- hazards, such as upright broilers, which cannot be protected ance Manual (Part No. 418087). with overlapping nozzles and therefore must be protected with nozzles dedicated to the appliance. • Ali appliance protection currently listed in the R-102 Design Manual (Part No. 418087) is also approved protection. Zone protection can be considered optional protection. ..., 1 . . .......____ SECTION 4—SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-58 REV. 11 2014-SEP-01 , . OVERLAPPING NOZZLE COVERAGE (Continued) Overlapping Appliance Nozzle and Hazard Zone Locations TABLE 1 1. All overlapping appliance nozzles must be the 245 nozzle Overlapping Nozzle Coverage (Zone Protection) for "end of zone" protection and the 260 nozzle for zone protection, and must be located under a common hood at Appliance Type Maximum Cooking Hazard the same height above the hazard zone, in a straight line Fryer 34 in. (863 mm) Deep x 5.8 ft2(0.5 m2) from right to left and aimed at the centerline of the hazard Griddle 30 in. (762 mm) Deep x Unlimited Length zone. The overlapping nozzle is used for both continuous Range 30 in. (762 mm) Deep x Unlimited Length overlapping and multiple group overlapping protection. Wok, Maximum 30 in. (762 mm)Diameter x 8 in. 2. The hazard zone must be positioned (located) so that all (203 mm) Deep appliance hazard surfaces are within the zone. For appli- Wok, Minimum 11 in. (279 mm)Diameter x 3 in. ance hazard surfaces smaller than the standard hazard (76 mm)Deep zone size, the hazard surface can be located anywhere Braising Fan/Tilt 34 in. (863 mm) Deep x Unlimited Length within the standard hazard zone. For appliance hazard Skillet" surfaces with listed protection exceeding the standard Lava Rock 26 in. (660 mm) Deep x Unlimited Length hazard zone size of 28 in. (711 mm) in depth (see Table Char-Broiler see Note 1) 4-1), the hazard surface(s) must be aligned with the back ( edge of the hazard zone, with the front edge overhanging Charcoal Broiler 30 in. (762 mm) Deep x Unlimited Length (4 in. (101 mm) Maximum Fuel Depth) the front of the zone. Mesquite Wood 30 in. (762 mm) Deep x Unlimited Length 3. The overlapping appliance nozzles must be located 40 in.to Broiler (6 in. (152 mm)Maximum Fuel Depth) 45 in. (1016 mm to 1143 mm) above the top surface of the Gas Radiant 36 in. (914 mm) Deep x Unlimited Length protected appliances. See Figure 4-115. Char-Broiler Exception No. 1: Nozzle dimensions for wok protection are Electric Char-Broiler 34 in. (863 mm) Deep x Unlimited Length measured to bottom of wok. Exception No. 2: When using •See Figure 4-113 for nozzle loci:aeon overlapping appliance nozzles in areas where there is a Note 1:Always try to place Lava Rock Char-Broiler(s)near the center Of the back shelf, the nozzle cannot be positioned in the shaded zone.When the Lava Rock Char-Broiler is the first or last appliance in the zone, area as shown in Figure 4-114, the outside edge of the broiler must not be more than 6 in.(152 mm)outside the . end nozzle. Also, back shelf must not extend more than 11 in. (279 I . mm) over the hazard zone and cannot be less than 18 in. (458 mm)above the hazard zone. See Figure 4-114. I OVERLAPPING NOZZ_E(S) -e—,14 0.12 IN, / COVER MUST NOT 1 I 1(0-ao4 mrn) CANNOT BE POSITIONED INTERFERE WrTH 1 / I iN THIS SHADED AREA EDGE OF Rh DISCHARGE / 43 424445 1111111i PATTERN 1 I 41 OHM 40-45 IN, 40 I i (1016-114,3mm) 1210 8 6 4 2 1 I 1 I 1, _CENTER LINE OF 1 ZONE —HAZARD ZONE I / 1' F3ACK vSHELF 11 IN,(279 mm) 1 t ZONE CENTER LINE MAXIMUM r. sa IN. FIGURE 4-113 (458 mm) MINIMUM mew 1 i E222222===.231 Le 28 IN.MI rrrn) •I FIGURE 4-114 1--- 1 R-702 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV, 11 PAGE 4-59 ..„... OVERLAPPING NOZZLE COVERAGE (Continued) Overlapping Appliance Nozzle and Hazard Zone Locations 4. The overlapping appliance nozzles must be located 0 in.to -Group Protection 12 in. (0 mm to 304 mm)forward of the centerline or aimline 1. For each group of protected appliances under a common of the selected hazard zone. See Figure 4-115. hood(s),the overlapping nozzles must be located from right to left so that each end nozzle is located a maximum of . 1 245 OR 260 NO77i g MUST BE AIMED STRAIGHT 11.5 in. (292 mm) inside the outside edge of the cooking DOWN OR BACK AT DEUTERUNE OF HAZARD ZONE hazard of each end appliance, and the inside overlapping _ nozzles must be located between the two end nozzles at a maximum spacing of 25.5 in. (647 mm). See Figures 4-116 and 4-117. ----":1" 480,4, 12(N. 0143 mm) - 1 r4A 44S7)mm)MAXIMUMEEN —tom muli—(304 mm) 1 OVERLAPPING NOZZLES b, 40 IN. H. i * ' $ A (1018 MM) I % / \ / 1 i \ / • 11.5 IN.--e. / 4— / \ / 1 / 1 --)i. \ 11.5 IN. (292 mm) i \ 1 ' / \ / \ / k (292 mm) MAXIMUM FROM \ / \ / i( /\ 1. i N \ '{ ,'‘EDGE OF / " ki• / \ MAXIMUM FROM EDGE OF FRONT...Ay' .....-...... . BACK OF ZONE COOKING i HAZARD / i \ / / \ /\ ‘ , \ ‘ r,COOKING 1 HAZARD OF ZONE CENTERUNE OF 28 IN. , HAZARD ZONE(711 mln) ZONE O FIGURE 4-115 0075.17 FULL.HOOD CONTINUOUS APPLIANCE PROTECTION _. TABLE 4-2 FIGURE 4-116 Overlapping System Piping Limitations COMB Max.Total 3/8 3/8 in. Max. Max. System Flow Pipe No.of Elevation Cartridge Size Numbers Length Elbows Rise Size 25.5 IN.(647 mm) 11.5 IN.(292 mm) 3 Gallon 6 75 ft 25 10 ft LT-30-R MAXIMUM MAXIMUM (11.4 L) (22.9 m) (3.0 m) + / 'I \ + / \+ V 1 6 Gallon 12 75 ft 25 10 ft Double 1.2..45 245 11.5 iN. -or. I 4 r 14 iv I r4- -4. 4 I 4e- 11.51N. (22.7 L) (22.9 m) (3.0 m) Tank/ (292 mt11) 245 260 245 25.5 IN, (292 mrn) Manifolded LT-A- MAXIMUM (847 mm) MAXIMUM 101-30* FROM / MAXIMUM FROM EDGE OF • - :\\. , EDGE OF 9 Gallon 18 75 ft 25 10 ft Double COOKING COOKING HAZARD EDGE Of HAZARD (34.1 L) (22.9 m) (3.0 m) Tank/ COOKING LT-A- . HAZARD 101-30* 50 ft(15.2 m) maximum pipe from first to last nozzle. GROUP APPLIANCE PROTECTION Note:On group appitariee protection,start and ono of EACH zone 50 ft(15.2 m) maximum pipe after the split on a split system. group must Oe protectec wiln a 245 nozzie, Use with regulated actuator only. FIGURE 4-117 C01720 ,Wiii.NNIANAWAMIII AVT.V.W.AVIMIRM69,1.26,00*AfsmerahnoJar....40,,,,,,”,......1.........wear., , SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-60 REV. 11 2014-SEP-01 •__ OVERLAPPING NOZZLE COVERAGE (Continued) Overlapping Appliance Nozzle and Hazard Zone Locations 4. On protected appliances. all hazard surfaces located in a -Group Protection (Continued) group must be within 40-45 in. (1016-1143 mm) from the 2. When obstructions are located adjacent to appliance(s) nozzle(s). Once that dimension is exceeded, a new group must be started. See Figure 4-120. protected by overlapping nozzles,the overlapping appliance nozzle spacing must start with the appliance(s) adjacent to Note:The supply pipe feeding nozzle groups is to be at the the obstruction. See Figure 4-118. same elevation.Adjust height for each group only by varying lengths of nozzle drops. 25.5 IN, 25.5 IN. 255 IN, 26.5 IN. 1.4,547 mm)[(.647 mm I) mr6)1(647 mmii 11.5 IN.(292 mm) MAXIMUM 1(iiix521,,r1;1).O1) _....... i mu,a*emu.*4_mAx,a+ ,....11.5 IN. (292 mm) A MAX 245 260 250 250 245 I 'I 1 I I 4 4 i 4 d END OF .....OUTSIDE f 1 NOZZLES lir ZONE EDGE OF I NOZZLES I f COOKING I 40 IN. I 1 1 I HAZARD 45 I . (1016mm) I (1149 rnm)1 40 IN, I 1 h END OF a 45 IN ZONE (1°16 Imm) I (1143,nrn) 1 y 1 1111111111111111111111111111111111 - HAZARD AREA a-1 1111 IA II—I- OGSTRUCTION Note:On continuous appliance orotecton,Still and end w5 245 nozzles and 260 nozzle(s)in the middle, FIGURE 4-118 CC.,719 in GROUP"A" 141 4 GROUP 3. When an appliance requires dedicated protection with a Note:On grantoustet=t3 pitttio=t1On;a0.12,5ri and wen,d or EACH zone groupnozz protected area intended for overlapping appliance nozzle FIGURE 4-120 protection, the group protection option will be required for appliances on either side of the appliances using dedicated protection. Group protection using overlapping appliance Detection Requirements For Overlapping Appliance nozzles must begin with the protected appliance(s)adjacent Protection to the dedicated appliance protected.An overlapping appli- When utilizing overlapping appliance protection. fusible link ance nozzle(s) must be positioned within 11.5 in. (292 mm) detectors must be installed on a maximum of 2 ft(0.6 m)centers, of the edge(s)of the appliance hazard surface area(s)adja- starting with detectors located in(under)the duct opening(s). cent to the dedicated nozzle protection. See Figure 4-119. Starting from the detector under the duct opening, add detectors I f , on 2 ft(0.6 m)maximum spacing until the complete length of the , plenum area is covered, from one end to the other.The location 1 of the last detector on each end of the plenum must not exceed EDGE OF COOKING 2 ft(0.6 m)from end of plenum. HAZARD / \ i Note: Standard detector placement can also be utilized when 1 using overlapping protection. However,the overlapping detector 11.5 IN. li 2,5.5 N..11' 4 25.5 W.I 25,5 IN I (292 mm)-a.• 1447 mm)) Li _....1 (647 VI(647"n) I 11.5 IN, option cannot be used when utilizing standard R-102 protection. MAX. i MAX. A 'di— A f (292 mm) o' Refer to Pages 4-71 -4-73 for detector placement. MAXmAx. 1 mAx I ) ' T I MAX, EDGE--•- 11.5 IN r 11.5 IN.(292 mm) I _EDGE OF (292 mm)MAX. I MAXIMUM I OF COOKING m . • HAZARD !) : 4 "4. COOKING HAZARD 1 1 : I AT 7 0_ I DEDICATED NOZZLE APPLIANCE Note:On group appliance protection,start and end of EACH zone group must be protected with a 245 nozzle FIGURE 4-119 mine R-702 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-61 TANK AND CARTRIDGE REQUIREMENTS For higher total flow numbers (23 to 110), multiple cartridges Once the hazard analysis is completed and the total nozzle flow and regulated actuators are required as shown in the System numbers are established, the quantity and size of agent tanks Selection Guide in*Appendix"Section and cartridges needed to supply the nozzles with the proper volumes of agent at the proper flow rates can be determined. ACTUATION AND EXPELLANT GAS UNE REQUIREMENTS For cartridges used in the regulated release mechanism, flow This section contains the guidelines for installing the actuation capacities, tank quantities and sizes, and regulated release and expellant gas lines between the regulated release mech- cartridge options are given in the table below. anism regulator, each regulated actuator regulator, and each agent tank.These limitations should be considered when select- Flow Size of Cartridge Options Total Quantity and Regulated Release irig the component mounting locations. Numbers Tank(s) Nitrogen Carbon Dioxide The actuation gas line is the length of pipe and/or hose that is run from either the AUTOMAN Regulated Release Assembly or 1 - 5 (1) 1.5 Gallon LT-20-R 101-10 the Remote Release Assembly that directs high pressure from 6-11 (1)3.0 Gallon LT-30-R 101-20 the cartridge in the release to actuate one or more additional 11 -16 (1) 1.5 Gallon Double 101-30 Regulated Actuator Assemblies. The actuation gas line can (1)3.0 Gallon consist of 1/4 in. Schedule 40 black iron, chrome-plated, stain- 16-22 (2) 3.0 Gallon Double 101-30'" less steel, or galvanized steel pipe and fittings, and/or factory 16-22 (2)3.0 Gallon Double - supplied stainless steel braided actuation nose. (Manifold) The expellant gas line is the length of pipe that is run from the 22-33 (3)3.0 Gallon Double - regulator in either the AUTOMAN Regulated Release Assembly When one or more regulated actuators are used, the following or a Regulated Actuator Assembly that directs regulated pres- tank and cartridge combinations apply for each regulated actu- sure to the agent storage tanks to pressurize the tank and ator: discharge the agent.The expellant gas line shall consist of 1/4 in. Schedule 40 black iron, chrome-plated, stainless steel, or Regulated Actuator Regulated Actuator galvanized steel pipe and fittings. Tank(s) Cartridge ___.. (1) 1.5 Gallon LT-20-R or 101-10 Actuation Gas Line-6 to 8*Tanks Maximum (1)3.0 Gallon LT-30-R or 101-20 -8 Tank maximum reflects the utilization of 3 tank regulate('actuators. (1) 1.5 Galion and LT-A-101-30 or 101-30"or 1. Use only 1/4 in. Schedule 40 black iron, hot-dipped galva- (1)3.0 Gallon double tank nized,chrome-plated, or stainless steel pipe and fittings. (2)3.0 Gallon LT-A-101-30 or 101-30"or double tank 2. The actuation gas line piping is installed from the regulated (2) 3.0 Gallon (Manifold) LT-A-101-30 or Double release mechanism to each regulated actuator connected (3)3.0 Gallon LT-A-101-30 or Double within the system.The total length of the actuation gas line from the regulated release assembly to the regulated actua- • For exceptions to maximum now numbers, see Orsaibubon Piping Requirements tor 1.5 gallon anti 3.0 ator)systems in thia Section, tor assembly(ies)must not exceed 20 ft(6.0 m)when using -•The 101.30 cartridge Qui not tie usieo when two 3.0 gauon taints are inandr.triet together. an LT-20-R, an LT-30-R nitrogen cartridge,or a 101-10 or a 101-20 carbon dioxide cartridge. See Figure 4-121. REGULATED ACTUATOR ASSEMBLY EXPELLANT GAS LINES , - NOT INCLUDED IN ACTUATION GAS LINE LENGTH TOTALS REGULATED 1.!!. ACTUATOR ASSEMBLY ACTUATION GAS LINE WITH AN LT-22-R. • LT-30-R,101-10 OR 101-20 CARTRIDGE _ MAXIMUM LENGTH OF 20 FT(6.0 m); MAXIMUM NO OF FITTINGS 9 are AUTOMAN ".1 . .401 ............... . REGULATED ACTUATOR ASSEMBLY REGULATED RELEASE '''................,...../..> ASSEMBLY „._ t .... +.-.0 FIGURE 4-121 032776 r, SECTION 4-SYSTEM DESIGN R.102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-62 REV. 11 2014-SEP-01 • _. ACTUATION AND EXPELLENT GAS UNE REQUIREMENTS 2. The actuation gas line piping is installed from the 101 (Continued) remote mechanical release to each R-102 regulated actua- Actuation Gas Line-6 to 8' Tanks Maximum(Continued) tor assembly.The total length of the actuation gas line from the remote mechanical release to the regulated actuator 3. If an expellant gas line is connected to the regulated assemblies must not exceed 100 ft (30.4 m). release assembly along with an actuation gas line, the total combined length of the actuation and expellant gas line 3. A combined total of 20 elbows and 9 tees may be used must not exceed 30 ft (9,1 m) when using a"double-tank" in these lines. Two 45° elbows equal one 90° elbow. See nitrogen cartridge or a LT-A-101-30 nitrogen cartridge or a Figure 4-123. 101-30 carbon dioxide cartridge. See Figure 4-122. 4. Use only a 101-10 carbon dioxide cartridge in the 101 4. A combined total of nine fittings may be used in these lines, remote mechanical release. eight 90° elbows and one tee. Two 45° elbows equal one 5. A safety vent relief valve(Part No. 15677) is required in the 90°elbow. actuation gas line to relieve residual pressure after actua- tion. Actuation Gas Line- 10 to 15*Tanks Maximum •15 Tank maximum reflects the utilization of 3 tank regulated actuators. Actuation Gas Line- Using 1/4 in. Stainless Steel Hose 1. Use only 1/4 in. Schedule 40 black iron, hot-dipped galva- •15 Tank maximum reflects the utilization of three tank regulated actuators, nized. chrome-plated, or stainless steel pipe and fittings. 1. Maximum total length of hose cannot exceed 17.5 ft(5.3 m). Note: Stainless steel hose and fittings can also be used. See Component Section for detailed information. Note: A combination of 1/4 in. stainless steel braided hose ACTUATOR AND EXPELANT GAS LINES WIlM A and 1/4 in. NPT pipe can be used as long as the total "DOUBLE TANK"CARTRIDGE OR A 101.30 CARTRIOGE combined actuation gas line length does not exceed 17.5 ft OR A LT-A-101-30 CARTRIDGE it; (5.3 m). Stainless steel braided hose cannot be used for MAXIMUM COMBINED LENGTH-30 FT(9.1 m); expellantgas lines. See Figure 4-123 for additional details. MAXIMUM COMBINED FITTINGS-9 l� ( 9 Al ill. r I 2. Maximum of five regulated actuators allowed .....P. 3. Actuated with remote release(Part No.433485)or Regulated 11 /,� ( Release Assembly(Part No.429853) -�REGULATED .. 11 1 i ' , ACTUATOR ilASSEMBLY REGULATED REGULATED ACTUATOR ACTUATOR ASSEMBLY EXPELLANT 611 I. ASSEMBLY GAS LINES NOT INCLUDED Jo- AUTOMAN IN COMBINED TOTALS REGULATED RELEASE ASSEMBLY FIGURE 4-122 20 ELBOWS SAFETY ' MAXIMUM RELIEF VALVE EXPELLANT1/4 IN.ACTUAT ION LINE- 4 TEES MAXIM!M GAS UNE 100 FT(30.4 m)MAXIMUM ft 9 4 t 4 I 1 I II I _ 1 ±II LH I I I i i i REGULATED ACTUATOR WITH TANK MAXIMUM OF 5 REMOTE RELEASE MECHANISMS AGENT TANK RE U REGULATED (RAPT NO.433465)5 MAXIMUM 1/4 IN.STAINLESS STEEL HOSE OPTIONS SAFETY , 42 IN.(1065 mm) 1/4 IN.STAINLESS RELIEF VALVE MAX.HOSE .STEEL HOSE CHECK VALVE LENGTH(TYP.) I ( 'I . t<�7 r �.� f .. f,� �m 1 _. MAXIMUM OF 1 1 1 1 I 1 I I r°.r-5 REMOTE I ir� H1 7 ' 1 1 1 ' 1 ' j , RELEASE I , 1 , I , I I i MECHANISMS 1 i I 1 I I i I 1 ' I I ! ' I I (PART NO. I I 1/4) �J t lJ I <J LJ i t I i 433435)OR I I I 1- - ONE REGULATED ..Ii I I i i RELEASE(PART_� NO.4298531 REGULATED ACTUATOR WITH TANK MAXIMUM OF 5 REGULATED ACTUATORS NOTE:WHEN MULTIPLE RELEASE ASSEMBLIES ARE UTILIZED,A 1/4 IN.CHECK VALVE FIGURE 4-�12323 (PART NQ.25E27)WILL BE REQUIRED AFTER EACH REGULATED RELEASE R-102 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-63 ACTUATION AND EXPELLENT GAS LINE REQUIREMENTS 3. if two tanks are connected to the regulated release (Continued) assembly in a multiple-tank system arrangement. the total Expellant Gas Line combined length of the actuation and expellant gas lines must not exceed 30 ft(9.1 m) when using a"double-tank" 1. The expellant gas line is installed from the regulated release nitrogen cartridge, an LT-A-101-30 nitrogen cartridge, or a mechanism in double, three, and multiple-tank systems, 101-30 carbon dioxide cartridge. See Figure 4-122, and from the regulated actuator assembly in multiple-tank 4. If three 3.0 gallon tanks are connected to the regulator in systems. The expellant gas line is the piping and/or hoseeither a regulated release or regulated actuator assembly, between the regulator and the tank-enclosure/tank-bracket only factory supplied expellant gas hose assemblies will assembly. The total length of the expellant gas line from be utilized. Refer to Distribution Piping Requirements — 9.0 the regulated release mechanism or each regulated actu- 1.. Gallon System,page 4-70 for additional design requirements. ator assembly must not exceed 30 ft (9.1 m) when using a "double-tank" cartridge, an LT-A-101-30 Cartridge, or a DISTRIBUTION PIPING REQUIREMENTS 101-30 Cartridge. See Figures 4-124 and 4-125. Once the nozzle placement and quantity of tanks has been determined, it is then necessary to determine the piping config- MAXIMANT GAS H- urations between the tank adaptor and each discharge nozzle. MAXIMUM LENGTH-3D Fr(9 t m): MAXIMUM NO,Of FITTINGS-9 This section contains the guidelines and limitations for designing the distribution piping so that the liquid agent will discharge from 1II the nozzles at a proper flow rate. These limitations should also be referred to when selecting the mounting location for the regu- I lated release mechanism and agent tank. �� General Piping Requirements �,a 1. All R-102 system piping is straight line.Therefore,the need for critical lengths and balancing is minimized. 2. 1Wo 45°elbows count as-one 90°elbow. AUTOMAN REGULATED 3. Each branch line includes the tee or elbow leading to it,and RELEASE ASSEMBLY all fittings within the branch line itself. t 4. The minimum piping length of Schedule 40,3/8 in.pipe from the tank outlet to any nozzle protecting a range,fryer,or wok FIGURE 4-124 must be 6 ft(1.9 m). moms EXPELLANT GAS LINE 5. Pipe lengths are measured from center of fitting to center of MAXIMUM LENGTH-30 FT i6.1 m). fitting. See Figure 4-126. MAXIMUM NO.OF FITTINGS- \ -4 CENTER TO CENTER • yyy111 ki =111==%1 FIGURE 4-126 111. o� it 6. All distribution piping must be 3/8 in.Schedule 40 black iron, chrome-plated, or stainless steel. Do not use hot dipped galvanized pipe on the distribution piping. 7. All threaded connections located in and above the protected area must be sealed with pipe tape. Tape should be applied to male threads only. Make certain tape does not extend over �EGULATEDACTUATOR the end of the thread, as this could cause possible blockage ASSEMBLY of the agent distribution. FIGURE 4-125 8. Before installing blow-off caps on nozzles, apply a small 00°"' amount of Dow Corning No. 111 silicone grease across the 2. A combined total of nine fittings may be used in these lines, opening in the nozzle tip and also a small amount coating the eight 90° elbows and one tee. Two 45° elbows equal one exterior of the blow-off cap.This will help keep cooking grease 90°elbow. from building up on the cap. 9. Tees used in the distribution piping can be used as thru tees, side outlet tees,or bull tees. i SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-64 REV. 11 2014-SEP-01 DISTRIBUTION PIPING REQUIREMENTS (Continued) Supply and Branch Line Identification SUPPLY LINE The R-102 distribution piping network is broken down into The Supply Line is defined as the length of pipe which runs from four specific pipe runs: the Supply Line.the Duct Branch Line, the agent tank outlet to the last branch line (whether a duct, the Plenum Branch Line, and the Appliance Branch Line. See appliance, or plenum branch line). This includes all supply line Figure 4-127. fittings except for the tees or elbows leading to the branch lines. DUCT BRANCH See Figures 4-127 and 4-128. UNE t•< SUPPLY LINE PLENUM APPLIANCE BRANCH UNE BRANCH LINE J NOTE:THIS IS A CONCEPTUAL DRAWING ONLY. THIS ISNOT AN ACTUAL INSTALLAT)ON. FIGURE 4-127 END OF SUPPLY LINE NOTE. THESE ARE EXAMPLES ONLY.OTHER CONFIGURATIONS CAN BE DESIGNED, . t ' END OF SUPPLY LINE END OF SUPPLY LINE END OF SUPPLY UNE ..•••• * * t * t IC\ r.. (NOPI PS FOR SUPPLY LINE TEE PLENUM PROTECTION) , END OF 0 1111 I If SUPPLY UNE II Ft SUPPLY FOR LINE TEE \ (NOZZLES PLENUM PROTECTION) BRANCH LINE CANNOT •" START AHEAD OF A BRANCH UNE CANNOT SUPPLY LINE TEE START AHEAD OF A SUPPLY LINE TEE FIGURE 4-128 R-102 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-65 DISTRIBUTION PIPING REQUIREMENTS (Continued) Supply and Branch Line Identification (Continued) PLENUM BRANCH LINE NOTICE The Plenum Branch Line is defined as the length of pipe which runs from the supply line to the plenum nozzle(s).This includes Branch lines cannot start ahead of a supply all branch line fittings as well as the tee or elbow used to start line tee. the branch line. See Figures 4-128 and 4-130. DUCT BRANCH LINE 4'" The Duct Branch Line is defined as the length of pipe which q-"' ..4 runs from the supply line to the duct nozzle(s). This includes all .r" �• "� •„� (T PLENUM INCLUDED) LINE branch line fittings as well as the tee or elbow used to start the 1 (TEE INCLUDED) branch line. See Figures 4-128 and 4-129. 1 t" PLENUM BRANCH UNE (TEE INCLUDED) DUCT BRANCH UNE ► , (ELBOW INCLUDED) ,.., I:1 .•I,' ..''.- $ DUCT BRANCH UNE (TEE INCLUDED) ,.••{ [4] FIGURE 4-130 r"'' � 000+sa 1.y + APPLIANCE BRANCH LINE DUCT BRANCH UNE The Appliance Branch Line is defined as the length of pipe ±TEES INCLUDED) `� which runs from the supply line to the appliance nozzle(s).This includes all branch line fittings as well as the tee or elbow used �+�..{ .y-,t to start the branch line. See Figures 4-128 and4-131. " "t $ ...-4...........H--- t ; 1 j A, APPLIANCE BRANCH LINES (TEES INCLUDED) FIGURE 4-129 .—.r Went FIGURE 4-131 1 I: SECTION 4—SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-66 REV. 11 2014-SEP-01 DISTRIBUTION PIPING REQUIREMENTS(Continued) START OF LAST BRANCH UNE Distribution Piping Requirements—1.5 Gallon System START OF FIRST DUCT, PLENUM.AND APPLIANCE PROTECTION BRANCH LINE 1. This option allows for duct protection, plenum protection, appliance protection,or any combination.However,only one SUPPLY duct nozzle may be used, either a 1W or a 2W, nozzle. LINE TEEMM°Us NOT LENGTH 2. All distributionpiping, su I and branch, must be 3/8 in. sxcEEoeFr supply (z.a m) Schedule 40 black iron, chrome-plated,or stainless steel. 3. Each 1.5 gallon tank allows a maximum of five flow ,4 numbers.' Il C:11 / .ii 4. The pipe length between the start of the first branch line and START OF LAST the start of the last branch line must not exceed 8 ft(2.4 m). © BRANCH LINE OF When the supply line is split,the combined length of both BTART RANCH LINES legs of the supply line(start of first branch line to start of last FIGURE 4-132 branch line) must not exceed 8 ft(2.4 m). See Figure 4-132. own. 5. The combined length of all branch lines must not exceed 22 ft(6.7 m). See Figure 4-133. fwNozzLE 6. The requirements of the following table must not be exceeded: 7N NOZZLE © 1NN� (BRANCH LINES IN BOLD) COMBINED LENGTH MUST NOT EXCEED 22 FT(6.7 In, FIGURE 4-133 000-as ►1.5 GALLON SYSTEM Supply Duct Plenum Appliance Requirements Line Branch Line Branch Line Branch Line Pipe Size 3/8 in, 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft E ft 4 ft 10 ft (12.1 m) (1.8 m) (1.2 m) (3.0 m) Maximum Tees 1 1 2 3 Maximum Row Numbers 5' 2 2 3 •Exceptions: t.Six Sow numbers are allowed when a duct branch one is the last brand)line on Me ploingr network and no IN nozzles are L:sed to Dotal woks or griddles. 2.Six flow numbers are allowed when six'IN nazzteS are used and none of the noz2les are used to protect woks,grlddies,ranges.and salamanders. Note:Only five flow numbers are allowed It a'IN nortie is used for wok.griddle,range,o•saiarnander protection. 3.Six low numbers are allowed when only two 3N nozzles are used. R-102 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-67 DISTRIBUTION PIPING REQUIREMENTS(Continued) Distribution Piping Requirements—3.0 Gallon System 1. The maximum length between the start of the first branch SUPPLY TEE line and the start of the last branch line must not exceed --""t, Or. 24 ft (7.3 m). When the supply line is split, the combined total of both legs of the supply line (from the start of the first branch line to the start of the last branch line) must not COMM exceed 24 ft(7.3 m). See Figure 4-134. 0 COMBINED LENGTH OF 2. The total length of all branch lines must not exceed 36 ft BOTH LEGS OF SUPPLY LINE MUST NOT 3 BRANCH UNES (10.9 m), See Figure 4-134. EXCEED 24 FT r,7,3 rn) 3. Use a 3/8 in.union to connect the tank adaptor to the 3/8 in. supply line. F 4. A maximum of two nozzles are allowed per duct branch line. 2W 11 1N N0771 5. The requirements of the following table must not be exceeded: 1N NOZZLE 10 230 NOZZLAIII°11. 245 NOZZLE 1/2N NOZZLE (BRANCH LINE IN BOLD) COMBINED LENGTH MUST C00702 NOT EXCEED 30 FT(10e m) FIGURE 4-134 3.0 GALLON SYSTEM Duct Plenum Appliance Requirements Supply Line Branch Line Branch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft 8 ft 4 ft 12 ft (12.1 m) (2.4 m) (1.2 m) (3.6 m) Maximum Rise 6 ft 4 ft 2 ft 2 ft (1.8 m) (1,2 m) (0.6 m). (0.6 m) Maximum 90° 9 4 4 6 Elbows Maximum Tees 1 2 2 4 Maximum Flow 11- 4 2 4 Numbers 'Exceptions: 1,Twelve flow nurnoers are Glowed in any one tank for duct and plenum prow-Jon OnrY 2.Twelve flow numbers are allowed with ally one tank using only two-flow appliance nozzles. 3. Twelve flow numbers are allowed wen any one tank using only titres-Row appliance nozzles. Special Instructions: 1. Twelve now numbers are allowed wrier%four Dean industries GTI Gas Fryers are protected low proximity as shown in Figure 4-86 on Page 4-32.The discharge piping must be as crown in Figure 4-57 on Page 4-32. 2. For certain McDonald's applicatons,11,3 flow numbers are allowed when using a combination ol one 2W duct nozzle,one 112N eieciroetatiC preopltator noz743, one IN plenum nozzle,and tour two-flow appliance)nozzles.Contact tne Applications Engineering Department for adartlormi inICfmation' imorsissamorrammor SECTION 4—SYSTEM DESIGN R•102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-68 REV. 11 2014-SEP-01 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements — 6.0 Gallon Manifolded LENGTH OF PIPING MUST NOT EXCEED 24 FT, (7.3 m)FROM START OF FIRST BRANCH UNE System TO START OF LAST BRANCH LINE As an option to piping two 3.0 gallon tanks separately, two 3,0 gallon tanks can be manifolded together to share a common agent distribution line. Only 3.0 gallon tanks connected to the • same regulator can be manifolded, The following requirements must be met when manifolding: AR' A 1. All piping must be 3/8 in. Schedule 40. V„ ST STANCHOF LINE 2. See Figure 4-136 for tank connections. 3. The length of supply line piping between the start of the first . branch line and the start of the last branch line must not exceed 24 ft (7.3 m). See Figure 4-135. When the supply line is split, the combined total of both legs of the supply line (from the start of the first branch line to the start of the 2W last branch line) must not exceed 24 ft(7.3 m), NOZZLES N NOZZLE 4. The combined length of all branch lines must not exceed 36 ft(10,9 m). See Figure 4-135. 5, A maximum of 22 flow numbers are allowed. 1N NOZZLE 6. The requirements of the following table must not be IN exceeded. Nozae © 1N NOZZLE © p 2 FLOW APPLIANCE NO77= (BRANCH LINES iN BOLD) COMBINED LENGTH MUST NOT EXCEED 36 FT(10.9 m) FIGURE 4-135 wwei ►6.0 GALLON SYSTEM Duct Plenum Appliance Requirements Supply Line Branch Line Branch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 32 ft 8 ft 4 ft 12 ft (9.7 mi (2.4 m) (1.2 m) (3.6 m) Maximum Rise 6 ft 4 ft 2 ft 2 ft (1.8 m) (1.2 m) (0.6 m) (0.6 m) Maximum 90° 8 4 4 6 Elbows Maximum Tees 2 2 2 4 Maximum Flow 22 4 2 4 Numbers R-102 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 _..... 2014-SEP-01 REV. 11 PAGE 4-69 DISTRIBUTION PIPING REQUIREMENTS(Continued) Distribution Piping Requirements—6.0 Gallon Manifolded Distribution Piping Requirements—With Independent Pipe System (Continued) Runs This configuration consists of two 3 gallon tanks.Both tanks are Independent pipe runs can also be used with the regulated connected to a common manifold tee and are pressurized from release assembly and the tank/enclosure assembly or tank a single double tank (Part No. 73022) nitrogen cartridge in the mounting brackets. See Figure 4-137. When manifolding is not regulated release assembly. See Figure 4-136, Note: A tank used, each of the two 3 gallon tanks utilize the piping limitations mounting bracket can be utilized instead of the tank/enclosure of a single tank system. assembly. -- 319 IN. L. 3/8 IN. 343 IN SUPPLY SUPPLY i USE HOSE/ , SEE GROMMET NOTE ,.. ..... PACKAGE No,i ,,. =IS= (PART No ..... .0---3/0 IN BRANCH HOSE/ c?= 418511) T's-------IN-LINE BURST DISC GROMMET I PACKAGE 1 ASSEMBLY-SEE NOTE NO.4 (PART NO. 418511) 11 I , ,-- 1 , — REMOVE ii''• Ellillk" j tr 1 BURST DISC- SEE NOTE NO 3 ( 3.0 3.0 - GALLON ; GALLON , !,' F3,0 GALLON ; 3.0 GALLON 1 TANK TANK % 1 II' DOUBLE TANK TANK TANK NITROGEN 'ir • DOUBLE TANK CARTRIDGE OR NITROGEN (LT./4.10HW I l'/ CARTRIDGE .k....*„.. ............. --- CARTRIDGE- ; OR LT-A-101-30 oceiv REGULATED 1 . CARTRIDGE 3.0 GALLON REGULATED RELEASE ACTUATOR ONLY) 1 I 4 ,. ' (LT-A-101-30 ASSEMBLY OR 3.0 GALLON REGULATED REGULATED RELEASE ASSEMBLY OR cARTRioGE_ ACTUATOR ASSEMBLY REGULATED ACTUATOR ASSEMBLY REGULATED TANK/ENCLOSURE ACTUATOR ONLY) TANK/ENCLOSURE ASSEMBLY ASSEMBLY FIGURE 4.137 NOTE 1:THE PIPE CONNECTION FROM TANK CENTER TO TANK 000716 CENTER CANNOT EXCEED 8 1/2 IN (218 mm),ALSO.OEM RELEASEARACKET ASSEMBLY CAN BE UTILIZED WHEN Note: If an expellant gas hose is to be used for a second tank NtANIFOLDINC3 3.0 GALLON TANK in an adjacent tank enclosure or tank bracket assembly, the NOTE 2:ONLY 3 GALLON TANKS CAN BE MANIFOLDED second tank will need to be installed on the left side of the NOTE 3; THE BURST DISC THAT IS PART OF THE TANK ADAPTOR./ BURST DISC ASSEMBLY eAusT BE REMOVED AND AUTOMAN Regulated Release, with the outlets a maximum of MODIFIED,SEPARATE THE ALUMINUM DISC MATERIAL 8.5 in. (215 mm)from center to center,similar to the manifolded FROM THE PLASTIC CIARKET.D'SCARO THE ALUMINUM DISC MATERIAL AND REINSTALL THE PLASTIC GASKET system In Figure 4-136. Otherwise, the second tank will require BACK INTO THE TANK ADAPTOR/BURST DISC ASSEMBLY. 1/4 in. NPT pipe instead of expellant gas hose, NOTE a•THE IN-LINE BURST DISC ASSEMBLY(PART NO 415Q70) IS TO BE MOUNTED AS CLOSE TO THE TANK OUTLET AS POSSIBLE,AFTER SYSTEM DISCHARGE,THE ASSEMBLY MUST BE DISASSEMBLED AND A NEW BURST DISC INSTALLED. FIGURE 4-136 ,raifr:wvf'i'M.Mii. ' fwwr mour w i..l.....l..hn/n`wlniielimWaYJAWagi11: PO..Nu✓.nu...andrw./M04A9vMw¢WMMw we•ira w..�.......,.. SECTION 4-SYSTEM DESIGN R-702 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-70 REV. 11 2014-SEP-01 • _... DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements-9.0 Gallon System This optional configuration consists only of three 3-gallon tanks. all pressurized from a single double-tank nitrogen cartridge with �- _ expellant gas hoses connected as shown in Figure 4-138.Tanks I � No, 1 and No.2 must be connected directly to the regulator with separate expellant gas hoses and Tank No.3 must be connected i ! to Tank No.2 with a third expellant gas hose as shown in Figure 4-136. Each tank must be connected to an independent dist ibu- tion piping network as shown in Figure 4.138. Distribution piping l� ---�- --- , T. ii : requirements for each network must be as follows: i 1. The maximum length between the start of the first branch if line and the start of the last branch line must not exceed i`. fj s 24 ft (7.3 m). When the supply line is split, the combined : 5 , , total of both legs of the supply line (from the start of the , , first branch line to the start of the last branch line) must not I? i I exceed 24 ft(7.3 m). See Figure 4-134. i 1 i 31 10 ? 3.0 3.0 2. The total length of all branch lines must not exceed 36 ft s'i TANK ON I TANK TANK j (10.9 m). See Figure 4 138. itl No.3 , NO.2 No.t �� l 3. Use a 3/8 in.union to connect the tank adaptor to the 3/8 in. f - - supply line. ,,_ `_) „". 4. A maximum of two nozzles are allowed per duct branch line. TWO TANK ENCLOSURE3 GALLON REGULATED DOUBLE TANK NITROGEN ASSEMBLY(PART NO, RELEASE ASSEMBLY, CARTRIDGE OR LT-A.101.30 CARTRIDGE 5. When using this 9.0 gallon system configuration, no mani- ;o SAND GROMMETS) REGULATED OR 3 DN (REGULATED,ACTUATOR folding of distribution piping is allowed. ACTUATOR ASSEMBLY ONLY) 6. When an AUTOMAN Regulated Release is utilized in this NOTE: WHEN THREE 3.0 GALLON TANKS A.RE CONNECTED TO ONE NAL configuration,additional regulator actuators cannot be used. AUTOMAN EGUL TED ACTUATOR(S)OR s)ASSEMBLES�NO USED.O 7. Only 3-gallon tanks can be utilized in this configuration. FIGURE 4-138 8. The requirements of the following table must not be 008/26 exceeded for each 3-gallon tank: ►9.0 GALLON SYSTEM Duct Plenum Appliance Requirements Supply Line Branch Line Branch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft 8 ft 4 ft 12 ft (12.1 m) (2.4 m) (1.2 m) (3.6 m) Maximum Rise 6 ft O ft 2 ft 2 ft (1.8 m) (1.2 m) (0.6 m) (0.6 m) Maximum 90° 9 4 4 6 Elbows Maximum Tees 1 2 2 4 Maximum Flow 11* 4 2 4 Numbers 'Exceptions: Twelve low numbers are allowed in any one tank for duct and delirium protection ONLY. 2,Twelve flow numbers are allowed with any one tank using only two•ttow appliance nozzles 3.Twelve flow numbers are allowed with any one tank using only three-flow appliance nozzles. Special instructions: s,When bur Dean Indusines 3Tn 3as Fryers are protected at low proximity as shown in Figure 4-65 on Page 4.32,the discharge piping must be as shown in Figure 4-67 on Page 4-32, 2. For certain McDonald's applications.11.5 flew numbers are allowed when using a combination of one 2W duct nozzle,one 1/2N electrostatic precipitator nozzle. one 1 N plenum norpe.and tour two-flow appt ince nozzles.Contact the Applkaflone Engineering Departrnent for additional Conflation. ..." ..... ....... ........_......„.„,„..... . . ,,,,,,,, , , ,,,..„,„ R-702 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-71 DETECTION SYSTEM REQUIREMENTS Once the fire suppression system design has been determined, a detection system design must be completed. This section contains guidelines and limitations for detection system instal- I lation. . —• — Detector identification The two types of detectors are distinguished from each other by their location in the detection system. 2°MAXIMUM •. 1.The Terminal Detector is the last in a series of detectors, or the only detector used in a single-detector system. This detector is thus named because it is at the point at which the wire rope ends,or"terminates." •. 2.A Series Detector is any detector located in-line between the INOWO 111.111111 regulated release mechanism and the terminal detector. Detector/Pulley Elbow/Conduit Offset Design Limitations FIGURE 4-139 1.Conduit runs, pulley elbows, and number of detectors per Va1171 system must be within the approved system guidelines.The following requirements must not be exceeded: NOTICE Maximum Maximum Maximum When gas appliances are used and the flue Number of Number of Length of gases from the burner are exhausted into the Detectors Elbows 1/2 in. Conduit duct, the detector must be kept out of the air per System per System per System stream of these exhaust gases.These gases Scissors Style 15 20 150 ft(45.7 m) can be very hot and could actuate the system Detector unnecessarily. (Without Duct openings that are long and narrow or Offset Conduit large enough to require multiple duct nozzles Scissors Style 15 16 150 ft(45.7 m) may require additional detectors. Detector(With Offset Conduit ELECTROSTATIC PRECIPITATOR 2.If the hazard requires more than 15 detectors, up to five If an electrostatic precipitator is located at or near the base of 101 Remote Releases (Part No. 433485) can be used for the exhaust duct, it is necessary to locate a detector below the system actuation. Each 101 remote release allows the use precipitator, at the base of the duct, and also locate one in the of a maximum of 15"scissor"style detectors(14 series and duct,just above the precipitator. See Figure 4-140. 1 terminal)for a total of 75 detectors if needed. When installing the detector bracket and system conduit, make Detector Placement Requirements certain they do not interfere with the operation of the precipitator. EXHAUST DUCTS Note: On secondary filtration units utilizing multiple filter stages/ .media,contact Technical Services for instructions. Each exhaust duct must have at least one detector installed in the duct entrance, located in the airstream of the cooking vapors, or at a maximum of 20 ft (6.0 m) into the duct opening. See Figure 4-139 I i ;,. NW Immo! FIGURE 4-140 =ow - SECTION 4-SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-72 REV. 11 2014-SEP-01 DETECTION SYSTEM REQUIREMENTS(Continued) Detector Placement Requirements (Continued) NOTICE COOKING APPLIANCES The conduit offset can be used at the top or If the cooking appliance is located under an exhaust duct where bottom of the regulated release to change direction of the conduit. The conduit offset a detector has been mounted, it is normally not necessary tc utilize another detector for that cooking appliance, provided the cannot be used with pulley tees. All other detector is not more than 12 in. (304 mm) into the duct and the changes in direction must be made by using appliance has no larger cooking surface than 48 in. x 48 in. ANSUL approved pulley elbows (Part No. 54 (1219 mm x 1219 mm). See Figure 4-141. 4232 or 415670), See Figure 4-142. Note: If two appliances are located under a duct opening where a detector has been mounted and both appliances together do not exceed a cooking surface of 48 in. x 48 in. (1219 mm x 1219 mm) and the detector is located above both the protected appliances, it is not necessary to utilize an additional detector provided the duct detector is not more than 12 in. (304 mm)into the duct opening. 111111 II 0 0 0 APPLIANCE APPLIANCE APPLIANCE REQUIRES COVERED BY REQUIRES SEPARATE DETECTOR SEPARATE DETECTOR UNDER DUCT DETECTOR FIGURE 4-142 LOC2 7C Fusible Link Selection FIGURE 4-141 x'26* When possible, temperature readings should be taken at each Each cooking appliance with a continuous cooking surface not detector location to determine correct fusible link temperature exceeding 48 in. x 48 in. (1219 x 1219 mm)can be protected by rating. Temperature can be recorded using either a maximum a minimum of one detector. Cooking appliances with a continu- registering thermometer (Part No. 15240) temperature tape or ous cooking surface exceeding 48 in.x 48 in.(1219 x 1219 mm) any other accurate thermometer. must be protected by at least one detector per 48 in. x 48 In, (1219 x 1219 mm) cooking area. Detectors used for cooking Q appliances must be located above the protected appliance toward the exhaust duct side of the appliance. The detector should be located in the air stream of the appliance to enhance system response time. I TEMPERATURE ON FUSIBLE RAMRERATING STAMPED Note: For overlapping detector coverage, see Page 4-60 for LINK BODY design requirements, \••••"/ e--5 .—Lf e Detection Line Requirements 4 men CONDUIT • SL STYLE A-PC STYLE xvri Rigid conduit or 1/2 inch EMT thin-wall conduit may be used. FIGURE 4-143 Standard steel conduit fittings (compression type are recorn. Select correct UL Listed fusible link(s) for installation in detec- mended) must be employed to properly install the detection tor(s) according to the temperature condition. Two styles are system. All conduit or pipe must be firmly supported. When available. See Figure 4-143. See Component Section for using pipe, make certain that all ends are carefully reamed, detailed temperature ratings. deburred and blown clear of chips and scale before assembly. R-702 Restaurant Fire Suppression Manual SECTION 4-SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-73 DETECTION SYSTEM REQUIREMENTS (Contlnued) TEE CLOSE TO AUTOMAN(EXAMPLE) Electric Thermal Detector PULLEY TEE When electric thermal detection is used, the detection circuit 12 iN. must be supervised in accordance with NFPA 17A, Standard for (304 rim) Wet Chemical Extinguishing Systems.Electric thermal detectors must be used in conjunction with either the AUTOPULSE 542R Control Panel (Part No. 433607) or the AUTOPULSE Z-10 Control Panel (Part No. 430525), and the 24VDC Regulated AUTOMAN GAS VALVE Ofi GAS VALVE OR Release Assembly. MANUAL PULL MANUAL PULL 149 FT(4.54 m)AND 20 PULLEY ELBOWS MAXIMUM Note: Consider the rate of temperature increase in the location PER EACN SIDE OF TEE chosen for the detector when using electric thermal detection. TEE CLOSE TO GAS VALVES OR MANUAL PULL(EXAMPLE) A transient rush of warm air up to 40 °F (4 °C) per minute may expand the shell, but not enough to trigger the AUTOPULSE 12 IN. 12:N. control panel. Temperature increases over 40 °F (4 °C) per (304 mm) Iri (304 rnin) minute however, may initiate an alarm condition in the control PULLEY TEE panel. GAS VALVE OR GAS VALVE OR After determining the maximum ambient temperature at the MANUAL PULL MANUAL PULL AuTOmAN thermal detector location, select the correct thermal detector 149 FT(48.4 m)AND 20 PULLEY ELBOWS BETWEEN according to the temperature condition chart in the "System AUTOMAN ANC;TEE Components"section. TEE HALFWAY BETWEEN AUTOMAN AND GAS VALVES OR MANUAL PULL(EXAMPLE) MANUAL PULL STATION REQUIREMENTS 75 FT(22,8 ml AND 10 PULLEY ELBOWS A remote manual pull station allows the R-102 system to be manually operated at some point distant from the regulated 75 FT(22.8 m)AND 75 ET(22.8 m)AND release assembly.The pull station should be installed at a height 10 PULLEY ELBOWS 10 PULLEY ELBOWS of 42-48 in. (1067-1219 mm), in accordance with the require- PULLEY TEE 6 merits of the American Disabilities Act (ADA) and the Authority AUTOMAN having Jurisdiction. and located in the path of egress. The pull GAS VALvE OR GAS VALVE OR MANUAL PULL MANUAL PULL station is the only source of manual actuation of the regulated FIGURE 4-144 release assembly. COISC7 The total length of the cable used for each manual pull station w Manual Pull Station-Part No. 435960 or 434618 within a system must not exceed 150 ft(45.7 m). Parts that may be used for installation of a metal stamped The maximum number of pulley elbows that may be used per remote manual pull station are: pull station is 20. Part No. Desc lion One pulley tee is allowed per cable system. . Remote Manual Pull Station Assembly" 435960 The maximum length of cable from the AUTOMAN to a pull Remote Manual Pull Station Assembly 434618 station is 150 ft (45.7 m) with a maximum of 20 pulley elbows Pulley Elbow 423250 used per side of the tee.As the tee Is located farther from the Pulley Elbow 415670 AUTOMAN,the 150 ft(45.7 m)maximum must be observed but Pulley Tee 427929 as pulley elbows are placed between the AUTOMAN and the *Assam*Includes parts iiSISC wow, tee,they must be deducted from the available pulley elbows(20) 1/16 in.Stainless Steel Cable 50 ft(15.2 m) 15821 allowed on each side. Oval Press-To-Crimp Sleeves 4596 Example:If 10 pulley elbows are placed between the AUTOMAN Glass Break Rod (1) 4834 and the pulley tee,the maximum available pulley elbows left for use on each side of the tee is 10 per side. See Figure 4-144 for three different examples. (Note: Both must be gas valves or both must be pull stations. Mixing is not allowed.) SECTION 4—SYSTEM DESIGN R-102 Restaurant Fire Suppression Manual } UL EX3470 ULC EX3470 PAGE 4-74 REV. 11 2014-SEP-01 �� MECHANICAL GAS VALVE REQUIREMENTS ELECTRICAL GAS VALVE REQUIREMENTS An ANSUL or ANSUL approved mechanical gas shut-off valve A UL Listed electrically-operated gas shut-off valve can be system can be attached to the R-102 system.The system works attached to the R-102 system to provide an electrical means of both mechanically and pneumatically by use of an air cylinder shutting off the gas line at a predetermined point. if an electric located inside the regulated release assembly. Upon actuation gas shut-off valve is used in the system it must be attached of the fire suppression system, a pneumatically-operated air with both an electric (snap-action) switch and a manual reset cylinder assembly will mechanically close the gas shut-off valve. relay. For more information on the types of electric(snap-action) The total length of the cable for each mechanical gas valve must switches,refer to the Electrical Switch, Field Installation section. not exceed 150 ft (45.7 m). The maximum number of pulley The manual reset relay is reviewed in this section. elbows that may be used is 20 for each valve. Ali electrical connections should be performed by a QUALIFIED One pulley tee is allowed per cable system. ELECTRICIAN and in accordance with authority having The maximum length of cable from the AUTOMAN to a gas valve jurisdiction. is 150 ft (45.7 m) with a maximum of 20 pulley elbows used per The following is a brief explanation of how the R-102 system side of the tee.As the tee is located farther from the AUTOMAN, operates with an Electric Gas Shut-off Valve attached: the 150 ft (45.7 m) maximum must be observed but as pulley V.fdh the regulated release cocked in the ready condition, the elbows are placed between the AUTOMAN and the tee, they normally closed contacts in the snap-action switch allow current must be deducted from the available pulley elbows (20) allowed to flow to the manual reset relay. With the relay coil energized, on each side. normally open contacts in the reset relay close, allowing the Example: If 10 pulley elbows are placed between the AUTOMAN solenoid in the gas valve to be energized. and the pulley tee, the maximum available pulley elbows left for Once the R-102 system is activated, the normally closed use on each side of the tee is 10 per side. See Figure 4-144 for three different examples. contacts in the snap-action switch will open, de-energizing the Parts that may be used for installation of a Mechanical Gas reset relay.This will,in turn,open the contacts in the relay which will cause the gas valve to become de-energized and close. Shut-off Valve are: Part No. The system must be re-armed and the'push to reset"button on Gaascr Gationthe reset relay must be operated to reopen the gas valve. s Valve/Actuator 3/4 in.Assembly{ANSUL)" 55598 Gas Valve/Actuator 1 in.Assembly(ANSUL)' 55601 It is important to note that a power failure or an electrical power Gas Valve/Actuator 1 1/4 in.Assembly(ANSUL)" 55604 interruption will cause the gas valve to close even though the Gas Valve/Actuator 1 1/2 in.Assembly(ANSUL)" 55607 system was not fired. Gas Valve/Actuator 2 in.Assembly(ANSUL)' 55610 In either case, whether in a fired condition or when a power Gas Valve/Actuator 2 1/2 in.Assembly(ASCO)' 25937 failure has occurred, the manual reset relay and electric gas Gas Valve/Actuator 3 in.Assembly(ASCO)• 25938 shut-off valve must be reset to resume a normal operating condi- Pulley Elbow 423250 ton. For resetting, refer to the 'Recharge and Resetting Pulley Elbow 415670 Procedures" section in this manual. Pulley Tee 427929 1/16 in. Stainless Steel Cable 15821 or 50 ft(15.2 rn)or 500 ft(152.4 m) roll 79653 Oval Press-To-Crimp Sleeve 4596 Stop Sleeve(2) 26317 'Assembly+ncMWes pens IFsieC beFow: Air Cylinder Assembly 15733 Air Cylinder 15521 Tubing Assembly 15529 Copper Tubing, 1/8 in. 15525 Male Elbow 15523 Male Connector 15522 Machine Screw(2) 15421 Hex Nut(2) 15527 Lockwasher(2) 4141 Visual Inspection Seal (2) 197 All valves above are UL listed and approved. They may be mounted in any position. Pipe threads are type NPT. Ambient operating temperature range of all valves is 32 °F to 120 °F (0 °C to 49 °C). The valves are not weatherproof and must be located indoors in areas approved by the "authority having jurisdiction." „,..........................„.„„..........„„......„.„,„„.„...,..„„.„„„,..,.,„„------_,...,—„----..„. „,.„. . ,, .. ..,..„--..„_..._,..... R-702 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN UL EX3470 ULC EX3470 ,..., 2014-SEP-01 REV. 11 PAGE 4-75 ELECTRICAL GAS VALVE REQUIREMENTS(Continued) ELECTRICAL SWITCH REQUIREMENTS Approvals Note: Electrical connections shall not be made in the ANSUL gas valves listed in this section are UL listed and AUTOMAN. approved for 110 VAC. If more information is required, refer to The electric (snap-action) switches for the R-102 system are the Gas and Oil Equipment List of Underwriters Laboratories, specially designed to fit the regulated release assembly. The Inc. under "Electrically Operated Valves Guide No. 440 A5” or switches are intended for use with electric gas valves, alarms, consult Tyco Fire Protection Products, Marinette, Wisconsin contactors, lights, contractor supplied electric power shut-off 54143-2542. devices, and other electrical devices that are designed to shut off or turn on when the fire suppression system is actuated. if other gas valves are used, they shall be "UL listed electrical- (See Figures 5-122 through 5-124 in Installation Section for ly-operated safety valves for natural or LP gas as required, of reference). appropriate pressure and temperature rating, 110 VAC/60 Hz," The information on temperature and type of gas that the valves Contractors shall supply "UL listed, enclosed Industrial control are suitable for may be found in the Gas and Oil Equipment List equipment or magnetic switch having a rating matching that of of Underwriters Laboratories, Inc. under "Electrically Operated the cooking appliance,coil 110 VAC/60 Hz or 24 VAC/60 Hz." Valves Guide No. 440 A5." All electrical connections should be performed by a QUALIFIED The electrically operated gas valve must be of the type that ELECTRICIAN and in accordance with authority having needs to be energized to remain open. jurisdiction. , Note:For electrical wiring diagrams,see"Installation Instructions" Electric(Snap-Action) Switches that may be field installed are: Section, Pages 5-40 through 5-42. Part No. Description Parts that may be used for installation of a 110 VAC Gas Shut- 423878 One Switch Kit off Valve are: 423879 Two Switch Kit Description Part No. 423880 Three Switch Kit Electric Solenoid Valve, 3/4 in. NPT* 13707 423881 Four Switch Kit . 436770 Two Switch Kit(no wire leads) Electric Solenoid Valve, 1 in. NPT* 13708 ...._ *Electric Solenoid Valve, 1 1/4 in. NPT 550360 Each switch has a set of single-pole, double throw contacts Electric Solenoid Valve, 1 1/2 in. NPT' 13709 rated at 21 amp, 1 HP, 125, 250, 277 VAC or 2 HP, 250, 277 Electric Solenoid Valve, 2 in. NPT' 13710 VAC. Electric Solenoid Valve, 2 1/2 in. NPT` 550363 Note:A relay must be supplied by others if the equipment load Electric Solenoid Valve, 3 in. NPT.' 17643 exceeds the rated capacity of the switch. 1 *Manual Reset Relay(110 VAC) 426151 Electrical wiring and equipment shall be installed in accordance *Vitves are normalty dose when cie-enerspzed. with NFPA 70 (National Electrical Code) or the requirements of the authority having jurisdiction. ALARM INITIATING SWITCH REQUIREMENTS If a fire alarm system is provided, the fire extinguishing system The Alarm initiating Switch can be field mounted within the shall be connected to the alarm system in accordance with the AUTOMAN release. The switch must be used to close a super- requirements of NFPA 72, National Fire Alarm Code, so that the vised alarm circuit to the building main fire alarm panel when actuation of the extinguishing system will sound the fire alarm as the AUTOMAN release actuates.This action will signal the fire alarm panel that there was a system actuation in the kitchen well as provide the extinguishing function of the system. area. The switch kit contains all necessary mounting compo- If supervision of the electrical detection, electrical actuation or nents along with a mounting instruction sheet. See Page 5-39 electrical power supply circuit is provided, it shall give prompt for wiring information, audible or visual indication of trouble and shall be distinctive The switch is rated 50 mA, 28VDC. from alarms or indicators indicating operation or hazardous conditions as specified in NFPA 17A. Part No. Description 428311 Alarm Initiating Switch Kit SECTION 4-SYSTEM DESIGN R-702 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-76 REV. 11 2014-SEP-01 NOTES: