Loading...
Report OFFICE COPY 3T Project: Fred Shearer 3T split 08/03/2021 Prepared By: RECEIVED / C2O22 t7c20o O 02. AN OS �� 1*j<) ( c iL CITY UG'TIGARD OUILMIC DIVISION 3T Submittal Cover Sheet Unit Report Performance Summary Report Acoustic Summary Certified Drawings Feature Sheet Residential Carrier Products Bldr 1.29u Page 1 of 9 Unit Report For 3T Project: Fred Shearer 3T split 08/03/2021 Prepared By: • Outdoor Unit Parameters Indoor Coil Parameters Unit Model: 24ABB Unit Model: CNPV Unit Size: 3 Tons (Size 36) Unit Size: 3 Tons(Size 36) Voltage: 208/230-1-60 V-Ph-Hz Cabinet Finish: Painted Cabinet Width: 17 inch Refrigerant Type: Puron Furnace: Any Non-SEER Enhancing Outdoor Unit Dimensions and Weight Indoor Coil Dimensions and Weight Unit Length: 31.1875 in Unit Length: 21 in Unit Width: 31.1875 in Unit Width: 17.5 in Unit Height: 25.3125 in Unit Height: 17 in Unit Shipping Weight: 151. lb Unit Shipping Weight: 48.5 lb RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and below. The limited warranty period in years,depending on the part and the claimant,is as shown in the table below. Limited Warranty(Years) Item Original Owner Subsequent Owner Parts 10* (or 5) 5 Compressor 10* (or 5) 5 *If properly registered within 90 days of original installation,otherwise 5 years(except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration).See Warranty Conditions below. OTHER APPLICATIONS The warranty period is five(5)years on the compressor,and one(1)year on all other parts. The warranty is the original owner only and is not available for subsequent owners. Per new Department of Energy regional efficiency standards,13 SEER AC units manufactured after 1/1/2015 can only be sold and installed in the North region. Please consult the DOE standards for product eligibility in your area. Ordering Information Part Number Description Quantity Outdoor Unit 24ABB336ABN3 24ABB Comfort Series Air Conditioner with Puron Refrigerant 3 Tons 1 Cooling 13 SEER t ARI Conditions Dense Grille North Region (B Design) Indoor Coil CNPVP3617ALA Cased Vertical N-Coil Evaporator Coil with Puron 1 Painted 17 inch Aluminum The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product Residential Carrier Products Bldr 1.29u Page 2 of 9 Unit Report For 3T Project: Fred Shearer 3T split 08/03/2021 Prepared By: literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29u Page 3 of 9 Performance Summary For 3T Project: Fred Shearer 3T split 08/03/2021 Prepared By: System Performance System: 24ABB/CNPV Actual Clg Airflow: 1200.0 CFM System Quantity: 1 Standard Clg Airflow: 1200.0 CFM Altitude: 0.0 ft Total Net Clg Capacity: 33.52 MBH Furnace Type: Any Non-SEER Enhancing Net Sensible Clg Capacity: 26.48 MBH Linear Pipe Length: 0.0 ft Total System Power: 3.21 kW SEER @ ARI Conditions: 13.0 EER @ ARI Conditions: 10.5 System Parameters Outdoor Unit Parameters Indoor Coil Parameters Unit Model: 24ABB336ABN3 Unit Model: CNPVP3617ALA Region: North Region (B Design) Unit Size (Nominal): 3 Tons(Size 36) Unit Size (Nominal): 3 Tons(Size 36) Ent Air DB: 80.00 °F Voltage: 208/230-1-60 V-Ph-Hz Ent Air WB: 67.00 °F Clg Ent Air DB Ambient: 95.0 °F Ent Enthalpy: 31.44 BTU/lb Lvg Air DB: 59.57 °F Lvg Air WB: 58.30 °F Lvg Enthalpy: 25.23 BTU/lb Total External Static Pressure: 0.50 in wg Electrical Data Outdoor Electrical Data Unit Voltage: 208/230-1-60 V-Ph-Hz Fan Motor FLA: 1.10 Amps MCA: 18.1 Amps Max Fuse: 30 Amps Operating Range Min: 197 V Operating Range Max: 253 V Compressor RLA: 13.6 Amps Compressor LRA: 79.0 Amps The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29u Page 4 of 9 Acoustic Summary For 3T Project: Fred Shearer 3T split 08/03/2021 Prepared By: Outdoor Unit Parameters: Unit Model: 24ABB Unit Size: 3 Tons(Size 36) Variations: Dense Grille Octave Band Center Frequency, Hz 125 250 500 1k 2k 4k 8k dBA Sound Power,dB 50.5 61.0 64.5 67.0 62.5 60.0 52.5 A-Weighted Sound Power, dBA 75.0 Indoor Coil Parameters: Unit Model: CNPV Unit Size: 3 Tons (Size 36) Cabinet Finish: Painted Cabinet Width: 17 inch No Indoor sound data available. The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29u Page 5 of 9 Certified Drawing For 3T Project: Fred Shearer 3T split 08/03/2021 Prepared By: - A — r +2t ti 7,s i , t i it of t:4#�r t�+ tt i,s Ott 4'k - o- 17.6'..";111111107*.‘‘ '. , 7 tii9{w'# ^►tt tsut. �..._ -# t f' ! t� At'tit#3..t sit \---t\-F ,,. . * l 'Ili:.ir r. /' /I E ''w /' 1 . .5,y, Ott#. VII ..r. A eCtOtit C.,4t :IA% t ,--- Y x -I t t3.'i ' 1 s. , ,,,,% ,, , , ,,, 8--4., i - # c t 4ti:t RS 4446 Of US$at xk:Y$ iC kAgef 1 m 44* line tstt . ,,.►tt z s J rera X r*t#a,+ t5s vtt At ktOtttt. Outdoor Model Unit Model: 24ABB Shipping Dimensions and Weights Outdoor Unit Unit Size: 3 Tons (Size 36) Height 29.75 in Voltage: 208/230-1-60 V-Ph-Hz Width 33.31 in SEER: 13 Length 33.31 in PartNumber: 24ABB336ABN3 Operating Weight 134. lb Shipping Weight 151. lb Dimensions A B C D E F G H I J K 31.19 in 25.31 in 0.88 in 6.56 in 24.69 in 9.13 in 0.31 in 3.00 in 15.56 in 16.50 in 10.25 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29u Page 6 of 9 Certified Drawing For 3T Project: Fred Shearer 3T split 08/03/2021 Prepared By: •.:e**-k 3d d.. .•43,a.* �..lr4 . 11 htb` x3 � «.t,*r.40r .. .. . '` ifti ,L `. tt 10 ..* *mkt ** ,.t. a,• a,. imrM Indoor Coil Unit Model: CNPV Dimensions and Weights Indoor Coil Unit Size: 3 Tons (Size 36) Height 17.00 in Cabinet Finish: Painted Width 17.50 in Cabinet Width: 17 inch Length 21.00 in PartNumber: CNPVP3617ALA Shipping Weight 48.5 lb Dimensions A B C D E F 17.00 in 13.88 in 3.56 in 15.75 in 17.50 in 0.75 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. r t Residential Carrier Products Bldr 1.29u Page 7 of 9 BB3 24 Comfort eA� 13 Air Conditioner with Purono Refrigerant Carrier 1-11 to5 Nominal Torts t3rrt to the expert1.0 Product Data INOVS't RV LEADING FEATURES BENEFITS `:'.;: E flkitacy t .rila Colt)foil . r.41W40 :ts • ` t vii4ottl it 000toott Reitabtttt:- • Nos- *t •tottiroxe • o3 s°l rt * K. ;irtivott tote Conift)rit • Rittt z It • S rl :rd t t*ttcot woo= glat.0.4134 ttilltattiN mraboity t" t , ,rt s t+ t" ttt pan* c 4 tt.tt zt tratttrs ttinotiktut4 tvy atrt otbtt 4 ot • 4 14:4* t trout 003 tt r^ tt I. .tf tt t.`ttttltt'i taS5TML ^ rigr►t • Lit �'t:ttL Nefit itittintft ttetttaic4 set tins d+rrwuts t»t ire sstbj4+rt Ott l t ttarrttfst ns c g+t st , . Al*ttrtt to t r',-,;°,., 1 t t«x or_stt w #-.arts up,Ito, . rA . ,t t.* t"it ZO cs 1114 t saaor . tto tap s ) 40 sit + astray, Atom. r* ct up it,W tt. .i.*A in)trr4u roott*O4to izoittoot 002340 fxs VACAO: V.,.4 , •> I • t,+otrt ttartbtW t ;novo 7t —o r, Vcts +art Ix Page 8 of 9 Residential Carrier Products Bldr 1.29u CNPP, CNR11P, CNP'► u?;--1 fl Cr PV1J, C RV ys . vn o+rttcr Cc 1.,.'0E?..tw, C tt,ifl:r; '11014 tt,ttV Et Product Data taraa. .14sotal Z.a Wuxi fotst la *4 *s t^t 444 Ssstistlos 114 «4« «it " t a ..,,.....rel.. to *ors x 1sc sae ` s iw,u,'-, + ,a el".N..A,Its dL .. 4 4r mat° * eae A i **644 00044, sa osz.at 104 441 $44??CN& .60.X ast 91 ‘ 6 w7► **t ,4111014010440tot Qom * a soloaAss ssa4t4 swiaiiiit WO ': t►#0 't ass asx to a . = Win: w. ae h Max;drat! , •, 4 taaNtt 4440404trtaNt t +r+tN rwa * t ern sN, a * .oqq{■�� ,O,p■�■ ����.pps wwbb' +�g S1A D t¢L8111' S 0 : , set trar-adsc.arot4*sou ticesi-tt Dusk* C sarie Pm, — 1 t tt0 g .1:441100,.:10' Ygib+ tdr 4 4 : * .0, At t s ,,.. T «sfastatmtst ... ._ c . z e - essa a�at%Z e^# ts+ ,. ar ate:W t ttss r Ne Si s %.* N 1 XV# — 443 4-***** a aa 7w9 to .e GSoC ptsr4zzss i«I4 y *oak.s ,mt * 4 « * #6 t y,�... w «_• «tmstsossas a -::a sp szt 11644404s4 tot« 4444t.,-...t itssett 4* t *A 4-44. Residential Carrier Products Bldr 1.29u Page 9 of 9 4 58SBOA/58SB1A . 4—WAY MULTIPOISE Non—Condensing 33-1/3 in. GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh turn to the experts Product Data ® OES Gi_.N ,,osTA,,4,44. / /' - N ------ /*— • 4,„F �rACT nin;u A vow, f------ t---- F ', ISO 9001 EEO F F .. ,---y -y :—ICi: CERTIFIED F ` c ,.,.w aIr a arc ce,ry art Y F \ \ Use of the AHRI Certified TM Mark indicates a ® �- \c ` P- \ , manufacturer's participation in the program. For verification of certification for individual products, d -- t '!` F go to www.ahridirectory.org. P .. P. F ® PERFORMANCE ' • Single Stage gas valve o ® ® —C `r • Fixed Speeds,Constant Torque(FCT)ECM blower motor G 1 • QuieTech" noise reduction system • Microprocessor based control center • Enhanced diagnostics with LED and reflective sight glass • Stores fault codes during power outages • Adjustable heating air temperature rise a • Adjustable cooling airflow I • Power Heat'' Igniter • Draft safeguard switch to ensure proper furnace venting ', • Inner door for tighter sealing INSTALLATION FLEXIBILITY ,1 • 4-way Multipoise furnace,13 vent applications ill• A10247 • HYBRID HEAT®Dual Fuel System compatible THE 58SBOA/58SB1A GAS FURNACE • All models are chimney friendly when used with The 58SB01/58SB1A 4-way Multipoise Gas Furnaces feature accessory vent kit Carrier's QuieTech'' noise reduction system for incredibly quiet APPLICATIONS induced draft operation. Applications are easy with 4-way • Compact design-only 33-1/3 in.(847 mm)tall multipoise design, through-the-furnace downflow venting, 13 different venting options,and designed for easy service access.An • Propane convertible with gas conversion accessory inner blower door is provided for tighter sealing in sensitive • Convenient Air Purifier and Humidifier connections applications.The 58SBOA/58SB1A furnaces are approved for use with natural or propane gas,and the 58SB1A- Low NOx units are CERTIFICATON designed for California installations and meet 40 ng/J NOx • Cabinet air leakage less than 2.0% at 1.0 in.W.C.and emissions.Can be installed in air quality management districts with cabinet air leakage less than 1.4% at 0.5 in.W.C.when a 40 ng/J NOx emissions requirement. tested in accordance with ASHRAE standard 193 • Residential installations eligible for consumer financing through the Retail Credit Program SPECIFICATIONS 1 UNIT SIZE 045E14-12 1 045E17-12 070E14-12 070E17-12 070E21-16 1 090E17-14 RATINGS AND PERFORMANCE Input Btuh* All Standard 44,000 44,000 66,000 66,000 1 66,000 88,000 All Low NOx Upflow Nonweatherized ICS All Low Nox 42,000 42,000 63,000 63,000 63,000 84,000 Downflow/Horizontal All Standard Output Capacity(Btuh)t 36,000 35,000 54,000 54,000 53,000 71,000 All Low NOx Upflow Nonweatherized ICS All Low Nox 34,000 34,000 51,000 51,000 51,000 68,000 1 Downflow/Horizontal AFUEt 80.00 80.00 80.00 80.00 80.00 80.00 Certified Temperature Rise Range-°F(°C) 30-60 30-60 30-60 35-65 25-55 40-70 (17-33) (17-33) (17-33) (19-36) (14-30) (22-39) Certified External Static Pressure Heat/Cool 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.15/0.50 Airflow CFMt Heating 710 760 1090 985 1305 1203 f Cooling 1080 1215 1070 1005 ; 1545 ! 1210 4F ; ELECTRICAL 1 Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 5.6 7.6 5.6 5.6 10.0 8.3 Unit Ampacity 7.8 10.3 7.8 7.8 13.3 11.0 Maximum Wire Length(Measure 1 Way in Ft(M) 47(14.3) 36(11) 47(14.3) 47(14.3) 27(8.2) 33(10.1) Minimum Wire Size 14 1 Maximum Fuse or Ckt Bkr Size(Amps)** 15 9 Transformer(24v) 40va l External Control Heating 12va Power Available Cooling 35va 41 Air Conditioning Blower Relay Standard f CONTROLS r Heating Blower Control Solid State Time Operation Burners(Monoport) 2 2 3 3 3 4 t Gas Connection Size 1/2in.NPT GAS CONTROLS i Mfr.I WhiteRodgers Min.inlet pressure 4.5(Natural Gas) Gas Valve(Redundant) (In.W.C.) Max.inlet pressure 13.6(Natural Gas) (In.W.C.) Ignition Device Hot Surface Factory installed orifice Size 43 BLOWER DATA Direct Drive Motor HP 1/3 ; 1/2 1/3 3/4 3/4 1/2 Motor Full Load Amps 4.4 6.4 4.4 8.8 8.8 6.8 RPM(Nominal)Speeds 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5 Blower Wheel Diameter x Width -In.(mm) 10 x 6 10 x 8 11 x 8 11 x 8 10 x 10 11 x 8 (254 x 152) (254 x 203) (279 x 203) (279 x 203) (254 x 254) (279 x 203) * Gas input ratings are certified for elevations to 2000 ft.(610 M). In USA,For elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions. t Capacity in accordance with U.S.Government DOE test procedures. # Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide, high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 2 SPECIFICATIONS (continued) UNIT SIZE 090E21-16 090E21-20 090E24-20 110E21-20 110E24-20 135E24-20 155E24-20 RATINGS AND PERFORMANCE Input Btuh* All Standard 88,000 88,000 88,000 1 110,000 110,000 132,000 154,000 All Low NOx Upflow Nonweatherized All Low Nox 84,000 84,000 84,000 105,000 105,000 126,000 147,000 ICS Downflow/Horizontal Output Capacity All Standard 72,000 71,000 72,000 90,000 90,000 107,000 125,000 (Btuh)t All Low NOx Upflow Nonweatherized All Low Nox 68,000 68,000 69,000 85,000 86,000 102,000 119,000 ICS Downflow/Horizontal AFUEt 80.00 80.00 80.00 80.00 80.00 80.00 80.00 Certified Temperature Rise Range°F(°C) 35-65 25-55 30-60 30-60 30-60 40-70 45-75 (19-36) (14-30) (17-33) (17-33) (17-33) (22-39) (25-41) Certified External Static Heat/Cool 0.15/0.50 0.15/0.50 0.15/0.50 0.20/0.50 0.20/0.80 0.20/0.50 0.20/0.50 Pressure Heating 1418 1650 1565 1890 1930 1760 1995 Airflow CFM --- Cooling, 1445 1980 1960 2040 2005 1810 1965 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Min-Max 104-127 Range Maximum Unit Amps 8.3 13 10.3 13.4 10.7 10.7 10.7 Unit Ampacity 11 16.90 13.50 17.40 14 14 14 Maximum Wire Length(Measure 1 Way in 33(10.1) 34(10.4) 27(8.2) 33(10.1) 26(7.9) 26(7.9) 26(7.9) Ft(M)) Minimum Wire Size 14 12 14 12 14 14 14 Maximum Fuse or Ckt Bkr Size(Amps)** 15 20 20 15 20 20 20 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Heating Blower Control SolidState Time Operation Mono port( P ) 6 7 Burners 4 4 4 5 5 Gas Connection Size 1/2in.NPT GAS CONTROLS Mfr. WhiteRodgers Min.inlet pressure 4.5 Natural Gas) Gas Valve(Redun- ( dant) (In.W.C.) 4 Max.inlet pressure 13.6(Natural Gas) (In.W.C.) If Ignition Device Hot Surface Factory installed orifice Size 43 BLOWER DATA Direct Drive Motor HP 1/2 I 1 3/4 1 3/4 � 3/4 3/4 Motor Full Load Amps 6.80 11.50 8.80 11.50 8.80 8.80 8.80 F RPM(Nominal)Speeds 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5 Blower Wheel Diameter x Width-In.(mm) 10 x 10 11 x 11 11 x11 11 x 11 11 x 11 11 x 11 11 x 11 (254 x 254) (279 x 279) (279 x 279) (279 x 279) (279 x 279) (279 x 279) (279 x 279) '% * Gas input ratings are certified for elevations to 2000 ft.(610 M). In USA,for elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft. i? (305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions. t Capacity in accordance with U.S.Government DOE test procedures. 'r; t Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A A. filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16--in.(110 mm)wide, high efficiency media filter. ** Time-delay type is recommended. CS Isolated Combustion System •( r. ret 1 rd 3 i MODEL NUMBER NOMENCLATURE 6 13 1,2 3 4 5 Major 7,8,9 10 11,12 VoNepe 14 15,18 Gas Furnace Heeling stages Ter Min.AFUE/NOx Series Heating Input Motor Type Width (1-phase) War Series Airflow 59 M N 7 B 080 E 17 1 1 16 I I I I I I I I I I I 10=1000 CFM 12=1200 CPA 58=80% C=Comm.Variable- 14=1400 CFM Non-Condensing Speed 16=1600 CFM 59=90%+ B=Base 0=Sid NOx 80% Constant Airflow 1 20=2000 CFM Condensing C=Camlort 1=80%Low Nox (VCN ECM 2 22=2200 CFM E=Export --- E=Fixed-Speeds 3 M=Modulating N=Infinity 2=92% Constant Torque 14-142' 1=110V/90Hz — S=Single Stage P=Perlomranoe 5.95% 026=26,000 BTU (FCT)ECM 17.175' 2=230V/50Hz T=Two Stage U=Ultra Low 6=96% A 040=40,000 BTU V=Venable-Speed 21-21.0• Nox 7=97% B D60=60,000 BTU Corelant Torque 24-24.5" 8=98% C — ECM --- 155=155,000 BTU A190041 For California Residents: For installation in SCAQMD only:This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit,and thus is subject to a mitigation fee of up to$450.This furnace is not eligible for the Clean Air Furnace Rebate Program:www.CleanAirFurnaceRebate.com FURNACE COMPONENTS INDUCER MOTOR -- VENT ASSEMBLY ELBOW MAIN UMIT SWITCH PRESSURE o (BEHIND GAS VALVE) SWITCH `!_ /, �S�a�r ok I- l'/'l',, _ BLOCKED VENT t (��� - %ill SWITCH FLUE COLLECTOR A I BOX 4IIlk�! 0 Air— V��r' 0 • FLAME V. �• • SENSOR GAS VALVE .fir 4`1 T►J p II i MANUAL RESET �I— i GAS MANIFOLD LIMIT SWITCHES /I • ' 2' '' I 1 41 ::114 _3 . 3 trail -;,1 e !`,,, `-L�� ... �- HOT SURFACE IGNITOR a GAS BURNER m BLOWER ,�1 iill ; DOOR SAFETY ' SWITCH .1 0 . I FURNACE l . CONTROL BOARD fl ® - ' BLOWER AND e t_ MOTOR r 1. IL m I \� r. • A190086 NOTE: The furnaces are factory shipped for use with natural gas.These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. 4 ACCESSORIES DESCRIPTION PART NO. 045E14-12 045E17-12 070E14-12 070E17-12 070E21-16 090E17-14 KGBFR0401B14 X X External Bottom Return Filter Rack KGBFR0501B17 X X X KGBFRO601 B21 X KGAWF1306UFR X X X X Unframed Filter 3/4-in.(19 mm) KGAWF1406UFR X Flue Extension KGAFE0112UPH X X X X X X Combustible Floor Base KGASB0201ALL X X X X X X Downflow Vent Guard KGBVG0101 DFG X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X KGACA02014FC X X X X X X Chimney Adapter Kit KGACA02015FC Natural-to-Propane Conversion Kit* AGAGC8NPSO1A X X X X X X Propane-to-Natural Conversion Kit AGAGC8PNSO1A X X X X X X Blower Speed Tap Jumper Kit AGABLRJMP10A X X X X X X (10 pack) *Factory-authorized and field installed.Fuel conversion kits are CSA(formerly AGA/CGA)recognized. X=Accessory DESCRIPTION PART NO. 090E21-16 090E21-20 090E24-20 110E21-20 110E24-20 135E24-20 155E24-20 KGBFRO601B21 X X X External Bottom Return Filter KGBFR0701B24 X X X X Rack KGAWF1406UFR X X X KGAWF1506UFR X X X X KGAWF1406UFR X X X Unframed Filter 3/4-in.(19 mm) KGAWF1506UFR X X X X Flue Extension KGAFE0112UPH X X X X X X X Combustible Floor Base KGASB0201ALL X X X X X X X Downflow Vent Guard KGBVG0101 DFG X X X X X X X Vent Extension Kit KGAVE0101 DNH X X X X X X X KGACA02014FC X X X X X Chimney Adapter Kit KGACA02015FC X X Natural-to-Propane Conversion AGAGC8NPSOIA X X X X X X X Kit* Propane-to-Natural Conversion AGAGC8PNS01A X X X X X X X Kit Blower Speed Tap Jumper Kit AGABLRJMPIOA X X X X X X X (10 pack) *Factory-authorized and field installed.Fuel conversion kits are CSA(formerly AGA/CGA)recognized. X=Accessory ORIFICES LH32DB207 LH32DB202 LH32DB200 LH32DB205 LH32DB208 LH32DB078 See Installation Instructions for model, Gases LH32DB076 altitude,and heat value usages. LH32DB203 LH32DB201 LH32DB206 LH32DB209 LH32DB210 5 ACCESSORIES (continued) DESCRIPTION ACCESSORY ' HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Model HRV , ENERGY RECOVERY VENTILATOR Model ERV UV LIGHTS Model UVL e Carrier has a wide variety of thermostats for your system,please visit www.Carrier.com to see all thermostat and IAO products. a I DESCRIPTION ACCESSORY 14" 17' 21" 24" Carrier Carbon Monoxide Alarm(10 pack) COALMCCNRB02-A10 X X 1 X X Carrier Infinity Air Purifier-16x25(407x635 mm) DGAPAXX1625 X X Carrier Infinity Air Purifier-20x25 (508x635 mm) DGAPAXX2025 X X Carrier Infinity Air Purifier Repl.Filter-16x25(407x635 mm) GAPCCCAR1625-A05 X X Carrier Infinity Air Purifier Repl.Filter-20x25(508x635 mm) GAPCCCAR2025-A05 X X Cartridge Media Filter-16"(407 mm)(MERV 11) FILXXCAR0116 X X Cartridge Media Filter-16"(407 mm)(MERV 8) FILXXCAR0016 X X ,f Cartridge Media Filter-20"(508 mm)(MERV 8) FILXXCAR0020 I X Cartridge Media Filter-20"(508 mm)(MERV11) FILXXCAR0120 X Cartridge Media Filter-24"(610 mm)(MERV 8) FILXXCAR0024 X Cartridge Media Filter-24"(610 mm)(MERV11) FILXXCAR0124 X EZ Flex Cabinet Side or Bottom-16" EZXCAB--0016 X X EZ Flex Cabinet Side or Bottom-20" EZXCAB--0020 X X EZ Flex Replacement Filters 16" MERV 10 EXPXXFIL0016 X X EZ Flex Replacement Filters 16" MERV 13 EXPXXFIL0316 X X EZ Flex Replacement Filters 20" MERV 10 EXPXXFIL0020 X EZ Flex Replacement Filters 20" MERV 13 EXPXXFIL0320 X ' EZ Flex Replacement Filters 24" MERV 10 EXPXXFIL0024 X EZ Flex Replacement Filters 24" MERV 13 EXPXXFIL0324 X EZ-Flex Filter with End Caps-16"(407 mm)(MERV 10) EXPXXUNV0016 X X I EZ-Flex Filter with End Caps-16"(407 mm)(MERV 13) EXPXXUNV0316 X X { EZ-Flex Filter with End Caps-20"(508 mm)(MERV 10) EXPXXUNV0020 X EZ-Flex Filter with End Caps-20"(508 mm)(MERV 13) EXPXXUNV0320 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 10) EXPXXUNV0024 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 13) EXPXXUNV0324 X Media Filter Cabinet-20" FILCABXL0020 X Media Filter Cabinet-24" FILCABXL0024 X Media Filter Cabinet-16" FILCABXL0016 X X TYPICAL WIRING SCHEMATIC ---- FIELD 24-V WIRING ---- FIELD 115-,208/230-,460-V WIRING FACTORY 24-V WIRING - FACTORY 115-V WIRING NOTE 2 THERMOSTAT FIVE WIRE Q 7 Q Q Q TERMINALS FIELD-SUPPLIED THREE-WIRE 1 I DISCONNECT HEATING ONLY i 1 r y _— 1ti1 --- BLOWER DOOR SWITCH — -- --- 460-V 0-OR /' THREE _six• lin BL U Of-' i - 1�1 ___ PHASE C R ----+- ' WH HT� O O -� -- ---/ N 1 -- I■1 ---1 208/230-V =GND GND T 1 __ _ SINGLE ' 115-V FIELD- AUXILIARY R __ ANN 1�1 I PHASE SUPPLIED J-BOX o GND DISCONNECT NOTE 1 , i CONDENSING UNIT 24-V TWO TERMINAL WIRE BLOCK FURNACE NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation. 2. Some thermostats require a"C"terminal connection as shown. 3. If any of the original wire,as supplied,must be replaced,use , same tvoe or eauivalent wire. Representative drawing only, some models may vary. A190079 1 , fi t 'r i 6 f AIR DELIVERY - CFM (With Filter) Wire Test Airflow Delivery @ Various External Static Pressures Furnace Lead Function Color 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Gray Cooling.Do not use for heating. 1230 1190 1155 1120 1080 1045 1010 975 935 895 Yellow Alt Cooling or alt Heating 980 945 920 890 855 815 770 735 690 645 045E14-12 Orange Alt Cooling or alt Heating 770 720 685 640 600 560 520 475 430 385 Blue Heating or alt Cooling 710 660 620 580 540 490 455 415 375 335 Red Alt Cooling.Do not use for heating. 600 540 500 455 415 385 345 305 235 — Gray Cooling.Do not use for heating. 1370 1335 1295 1255 1215 1175 1135 1095 1055 1020 Yellow Alt Cooling or alt Heating 1130 1085 1040 995 955 910 865 825 780 730 045E17-12 Orange Alt Cooling or alt Heating 930 885 835 795 745 700 655 600 545 495 Blue Heating or alt Cooling 760 720 670 625 580 515 460 410 355 300 Red Alt Cooling.Do not use for heating. 610 500 445 375 320 260 200 135 — — Gray Cooling.Do not use for heating. 1205 1170 1143 1105 1070 1035 1000 960 925 885 Blue Heating or alt Cooling 1095 1060 1030 995 960 925 885 840 800 735 070E14-12 Yellow Alt Cooling or alt Heating 920 880 845 805 765 730 685 620 560 510 Orange Alt Cooling.Do not use for heating. 715 650 610 575 520 465 410 380 305 245 Red Alt Cooling.Do not use for heating. 635 490 445 375 315 270 205 230 190 140 Gray Cooling.Do not use for heating. 1185 1140 1095 1055 1005 960 915 865 820 780 Yellow Alt Cooling or alt Heating 1000 940 895 850 800 750 695 650 600 555 070E17-12 Blue Heating or alt Cooling 990 935 895 845 790 740 690 640 590 535 Orange Alt Cooling or alt Heating 855 775 720 660 605 560 495 435 385 335 Red Alt Cooling. Do not use for heating. 860 685 515 445 385 340 275 205 — — Gray Cooling.Do not use for heating. 1735 1685 1640 1595 1545 1495 1450 1405 1360 1310 Yellow Alt Cooling or alt Heating 1480 1435 1395 1340 1290 1240 1190 1135 1085 1030 070E21-16 Blue Heating or alt Cooling 1315 1275 1225 1180 1135 1085 1030 975 915 860 Orange Alt Cooling or alt Heating 1135 1080 1030 985 935 885 835 770 705 645 Red Alt Cooling.Do not use for heating. 980 930 875 820 775 715 665 595 530 455 , Gray Cooling.Do not use for heating. 1355 1320 1285 1245 1210 1165 1125 1080 1025 815 Yellow Alt Cooling or alt Heating 1295 1255 1220 1185 1140 1100 1055 1005 955 815 090E17-14 Blue Heating or alt Cooling 1220 1185 1150 1105 1065 1025 975 915 840 740 Orange Alt Cooling or alt Heating 1030 985 940 900 845 790 715 655 590 535 Red Alt Cooling.Do not use for heating. 945 905 855 800 750 670 600 540 490 435 Gray Cooling.Do not use for heating. 1625 1580 1535 1490 1445 1395 1340 1260 1135 995 Yellow Alt Cooling or alt Heating 1425 1380 1335 1290 1235 1185 1125 1075 1020 640 090E21-16 Blue Heating or alt Cooling 1440 1395 1350 1305 1255 1200 1145 1090 1040 950 ' Orange Alt Cooling or alt Heating 1260 1210 1160 1105 1050 990 935 880 820 755 Red Alt Cooling.Do not use for heating. 1095 1040 980 905 845 780 720 650 585 520 Gray Cooling.Do not use for heating. 2180 2130 2080 2030 1980 1925 1870 1805 1745 1680 Yellow Alt Cooling or alt Heating 1900 1845 1795 1740 1685 1635 1570 1500 1435 1375 090E21-20 Blue Heating or alt Cooling 1685 1620 1565 1505 1455 1385 1320 1260 1200 1140 Orange Alt Cooling or alt Heating 1390 1315 1240 1175 1095 1030 970 900 825 760 Red Alt Cooling.Do not use for heating. 1240 1155 1075 990 915 835 765 690 615 555 Gray Cooling.Do not use for heating. 2190 2135 2075 2015 1960 1900 1835 1775 1705 1630 Yellow Alt Cooling or alt Heating 1870 1810 1745 1685 1625 1565 1495 1420 1345 1280 090E24-20 Blue Heating or alt Cooling 1580 1510 1445 1385 1320 1240 1175 1115 1050 970 Orange Alt Cooling or alt Heating 1305 1220 1160 1075 1000 930 865 770 690 610 Red Alt Cooling.Do not use for heating. 1210 1075 1000 915 845 765 675 595 515 425 Gray Cooling.Do not use for heating. 2255 2205 2150 ' 2100 2040 1985 1920 1835 1735 1615 Blue Heating or alt Cooling 1945 1890 1830 1770 1715 1655 1600 1545 1480 1430 i 110E21-20 Yellow Alt Cooling or alt Heating 1600 1525 1465 1400 1335 1275 1210 1150 1080 1015 Orange Alt Cooling.Do not use for heating. 1420 1340 1280 1200 1140 1065 1005 925 865 790 Red Alt Cooling.Do not use for heating. 1280 1205 1140 1055 990 910 840 760 695 630 Gray Cooling.Do not use for heating. 2250 2190 2130 2070 2005 1950 1885 1820 1755 1685 Blue Heating or alt Cooling 1995 1930 1865 1800 1740 1670 1605 1535 1465 1400 110E24-20 Yellow Alt Cooling. Do not use for heating. 1540 1460 1385 1305 1235 1165 1095 1035 955 890 Orange Alt Cooling or alt Heating 1345 1195 1135 1055 980 920 845 770 695 620 Red Alt Cooling.Do not use for heating. 1335 1075 965 890 820 735 660 580 505 440 Gray Cooling.Do not use for heating. 2065 2005 1940 1875 1810 1740 1670 1600 1530 1470 Blue Heating or alt Cooling 1825 1760 1695 1630 1560 1490 1420 1350 1275 1205 135E24-20 Yellow Alt Cooling or alt Heating 1760 1690 1625 1555 1485 1415 1345 1275 1200 1130 Orange Alt Cooling.Do not use for heating. 1620 1550 1480 1405 1335 1260 1195 1130 1065 995 Red Alt Cooling.Do not use for heating. 1325 1260 1185 1100 1025 955 885 805 735 670 Gray Cooling.Do not use for heating. 2205 2150 2090 2030 1965 1905 1840 1780 1710 1645 Blue Heating or alt Cooling 2055 1995 1935 1875 1810 1750 1690 1615 1540 1460 155E24-20 Yellow Alt Cooling or alt Heating 1860 1795 1730 1670 1605 1540 1470 1395 1320 1250 Orange Alt Cooling. Do not use for heating. 1495 1430 1355 1285 1210 1130 1065 995 930 850 Red Alt Cooling.Do not use for heating. 1295 1085 1000 910 835 765 670 600 530 465 1. A filter is required for eaci return—air inlet.Airflow performance included 3/4—in.(19 mm)washable filter media such as contained in factory—authorized accessory filter rack.To determine airflow performance without this filter,assume an additional 0.1 In.W.C.available external static pressure. 2. Adjust the blower speed tabs as necessary for the proper air temperature rise for each installation. 3. --Indicates unstable operating conditions. 4. If the same motor speed tap is needed for heating and cooling,a Juniper Wire accessory kit is available(see Product Data sheet for the current Jumper Wire accessory part number),see Function column for applicable limitations. 7 n I y` . - \ 1 1 *,..4;,/ 1 6.ma!,,,3.y,,,,1::15 j: 41/ ' ILMINNIA SEE NOTES 1,2,4,5,7,8,9 SEE NOTES 1,2,4,5,7,8,9 HORIZONTAL RIGHT HORIZONTAL RIGHT A02068 A02070 r 4, 1 r 1 o� - 1 j A SEE NOTES 1,2,4,7,8,9 HORIZONTAL RIGHT A02069 1 l °'M II f e r e • SEE NOTES 1,2,4,7,8,9 SEE NOTES 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02064 A02065 I _q o. P ' SEE NOTES 1,2,4,5,7,8,9 SEE NOTES 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02066 A02067 8 1 - :• -•-'41k.-%•'=., •; • •ri-----.'--;':‘,(7111614111! 1 - • o _ 0 • TN, AI o O II= ■IIIIIIIIIIIIIIIIII N O• 1 pii., _ • L Lir-17:'!Y.S' SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02058 A02059 A02061 I I J 1 it1i-I i tlI ,I 1 1 1 `.l,, K, • 1 i „1 I 1 11 G:I 1 O 0 0 1 iliptsc.:c.„.,,,:.,f,,I 4 . r ___. , 0 „..„, ,,,,,,,,,,_ ,,,!. I • L...i.&\ Irilicr.. 0 i .. 1. ...,____________:_. .. gill . ...L..„7.)......,: .. ibk . • it a i i •.e 1 4� •! SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES: 1,2,3,4,5,7,8,9 SEE NOTES: 1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent,vent connector sizing and vent material: United States,latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA 54. 2. Immediately increase to 5-in. (127 mm)vent connector outside furnace casing when 5-in. (127 mm)vent connector required,refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when Downflow Vent Guard is used in downflow position. 4. Type B vent where required,refer to Note 1. 5. 4—in. (102 mm)single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details. 8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet metal screws,space approximately 180° apart. 9. Secure all other single wall vent connector joints with (3)corrosion-resistant screws spaced approximately 120° apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. 9 DIMENSIONS t 7 ry „.....__.4 ... ,.. ir '' ��. ...... .4 JIPII ,})]: ' l IF . r i ._ S :s {' yb 1 1 I J ... 711 ....+......a.........x— A190084 C TOP AND D VENT A B BOTTOM FLUE BOTTOM CONNECTION SHIP WT.LB. FURNACE SIZE CABINET WIDTH OUTLET WIDTH COLLAR INLET WIDTH SIZE (KG) 045E14-12 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 104(47) 045E17-12 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 119(54) 070E14-12 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 114(52) 070E17-12 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 120(54) 070E21-16 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 142(64) 090E17-14 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 131 (49) 090E21-16 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 137(62) 090E21-20 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 140(64) 090E24-20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 146(66) 110E21-20 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 146(66) 110E24-20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 161 (73) 135E24-20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 167(76) 155E24-20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 168(76) *135 and 155 size furnaces require a 5 or 6—in. (127 or 152 mm)vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete installation requirements. 10 ._ .. - Alik. GUIDE SPECIFICATIONS Gas Furnace Casing 58SBOA/58SB1A Casing shall be of .030 in. (.76) thickness minimum, pre-painted steel. General Inducer Motor Inducer motor shall be soft mounted to reduce vibration SYSTEM DESCRIPTION transmission. Furnish a fixed capacity gas-fired Draft Safeguard Switch furnace for use with natural gas or propane (factory Draft Safeguard Switch (blocked vent safeguard) shall authorized conversion kit required for propane); furnish be factory installed to reduce the possibility of vent gas cold air return plenum. infiltration due to a blocked or restricted vent pipe. QUALITY ASSURANCE Heat Exchangers Heat exchangers shall be a 4-Pass 20 gage aluminized Unit will be designed, tested and constructed to the steel of fold-and-crimp sectional design when applied current ANSI Z 21.47/CSA 2.3 design standard for operating under negative pressure. gas-fired central furnaces. Controls Unit will be 3rd party certified by CSA to the current ANSI Z 21.47/CSA 2.3 design standard for gas-fired Control shall include a micro-processor based central furnaces. integrated electronic control board with at least 11 service troubleshooting codes displayed via enhanced flashing Unit will carry the CSA Blue Star® label. LED diagnostic light on the control, a self-test feature that Unit efficiency testing will be performed per the current checks all major functions of the furnace within one DOE test procedure as listed in the Federal Register. minute, and a non-volatile memory replaceable Unit will be certified for capacity and efficiency and automotive-type circuit protection fuse. Multiple listed in the latest AHRI Consumer's Directory of operational settings available including, separate blower Certified Efficiency Ratings. speeds for heating, cooling and continuous fan. Cooling Unit shall carry the current Federal Trade Commission airflow will be selectable between 350 or 400 CFM per ton Energy Guide efficiency label. of air conditioning. DELIVERY,STORAGE AND HANDLING OPERATING CHARACTERISTICS Unit shall be shipped as single package only and is Heating Capacity shall be Btuh input; stored and handled per unit manufacturer's Btuh output capacity. recommendations. Fuel Gas Efficiency shall be 80% AFUE. Air delivery shall be CFM minimum at 0.50 In. W.C. WARRANTY(for inclusion by specifying engineer) external static pressure. Warranty certificate available upon request. Dimensions shall be: depth in. (mm); Products width in. (mm); height in. (mm) (casing only). Height shall be in. (mm) with A/C coil and in. (mm) overall with EQUIPMENT plenum. Components shall include: slow-opening gas valve to ELECTRICAL REQUIREMENTS reduce ignition noise, regulate gas flow, with electric switch gas shut-off; flame proving sensor, hot surface Electrical supply shall be 115 volts, 60 Hz, igniter, pressure switch assembly, flame rollout switch, single-phase (nominal). Minimum wire size shall blower and inducer assembly, 40va transformer; be AWG; maximum fuse size or circuit breaker low-voltage(heating)(heating/cooling)thermostat. shall be Amps. Blower Wheel and Blower Motor Galvanized blower wheel shall be centrifugal type, SPECIAL FEATURES statically and dynamically balanced. Blower motor of Refer to section of the product data sheet identifying fixed-speeds, constant torque ECM type shall be accessories and descriptions for specific features and permanently lubricated with sealed bearings, of available enhancements. hp, and shall be multiple-speed direct drive. Blower motor shall be soft mounted to the blower scroll to reduce vibration transmission. Filters Furnace may have reusable-type filters. Filter shall be in. (mm) (x) in. (mm). An accessory high efficiency Media Filter is available as an option. Media Filter. 11 Copyright 2019 Carrier Corp.• 7310 W.Morris St.• Indianapolis,IN 46231 . Edition Date: 06/19 Catalog No:58SBOA-03PD Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. Replaces: 58SBOA—02PD 12 Cam .-r SUBMITTAL Project —Untitled271 Date Monday, February 22, 2021 Table Of Contents Project: —Untitled271 02/22/2021 Prepared By: 02:22PM RTU-4 3 Unit Report 4 Certified Drawing 5 Performance Summary 8 Unit Feature Sheet 11 RTU-1,5 12 Unit Report 13 Certified Drawing 14 Performance Summary 17 Unit Feature Sheet 20 RTU-2,3 21 Unit Report 22 Certified Drawing 23 Performance Summary 24 Unit Feature Sheet 27 RTU-6 28 Unit Report 29 Certified Drawing 30 Performance Summary 33 Unit Feature Sheet 36 Packaged Rooftop Builder 1.57 Page 2 of 36 RTU-4 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM RTU-4 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.57 Page 3 of 36 Unit Report For RTU-4 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*** Unit Model: 48FCDA06A2A5-0A0A0 Unit Length: 6'2.375" Unit Size: 06(5 Tons) Unit Width: 3' 10.625" Volts-Phase-Hertz: 208-3-60 Unit Height: 2'9.375" Heating Type: Gas *** Total Operating Weight: 556 lb Duct Cfg: Vertical Supply/Vertical Return Low Heat *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are Standard One Stage Cooling Models provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size: 1/2 Condensate Drain Line Size: 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity: 2 Return Air Filter Size: 16 x 25 x 2 Unit Configuration Direct Drive-EcoBlue-Medium Static Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48FCDA06A2A5-0A0A0 Rooftop Unit 1 Base Unit Direct Drive-EcoBlue-Medium Static None Packaged Rooftop Builder 1.57 Page 4 of 36 Certified Drawing for RTU-4 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM ��c/,' / �,IHIS DOCUNFNT IS FNE PROPERLY 0E UII 1LINATE.CORTAFL SUNNISSIOM OF E _,OR I)O[11MENT3 NOTES: UNIT J X f/1B-- TWAT TUTIY NTE TS WITT NOT E DI TLC ERPRE55 CONRI�IOM DOES NO1 CONS 1 'RACT AXCC OA u TUT WRITTEN C NSEN NOT RE DISCLOSED CO OR USED ACCEPTANCE �NIAACT. 1. DIMENSIONS ARE IN INCHES. DIMENSIONS 33 3/8 18 5/8 a ry.,y„ rlFxO wRl llEx coxsExT. IN [ I ARE IN MILLIMETERS. ABFC•.04 [8471 14121 33 3/8 14 ll8 CONNECTION SIZES 2. CENTER OF GRAVITY 48E C+.OS [84ll [3777 - 33 3/6 -..- A 1 3/8' 1351 DIA FIELD POWER SUPPLY HOLE 48F64406 33 378 id 7/8 18461 3. y DIRECTION OF AIR FLOW [8477 1371J _ B 2 [507 DIA POWER SUPPLY KNOCKOUT 41 3/8 18 5/8 C 13/4" [511 DIA GAUGE ACCESS PI UG 48FC+.07 - - 32-I/8 ' ECONOMIZER HOOD I105I1 l4721 4. ALL VIEW DRAWN USING 3R0 ANGLE [8177 (OPTIONAL) D 7/8" 1221 DIA FIELD CONTROL WIAI NG HOLE 16 E 3/4"-14 NPF CONDENSATE DRAIN y d071 -- 25-5/B — F 1/2"-IA NPF GAS CONNECTION URN] RETURN AIR __ G 7 1/2 [641 DIA POWER SUPPLY KNOCK OUT 1� e_... THE-BASE CHANT �� �. \ oC� 10-TIN THESE HOLES REQUIRED FOR USE �� 12171 RE TURN CABTWROOSA00. 009A00 r���,,,��,,,;- .®�. AIR 11a11��lit THREADED WIRE AEO'D HOLE I1I�'11I���IIIIt,�1W2�� 77/ - CONDUIT SITE USE SIZES IMA%.1 1\ \\\\\�\�. • j o — w vz• 115v lra° [2z.ii ����� X 1/4 24V 7/8" 122 21 II 44-118 11 \�y¢'� 29-I/2 Y 3/A POWER 1-1/8" [28.61 [1120.91 ��'/ E •ALT. 17481 Y 17-3/4 Z. (009A001 1/2" FPT GAS 1-1/81 128.61 9 CONDENSATE -- .N 6' —1 'DRAIN OPENING SUPPL FOR "THRU-THE-BASEPAN" FACTORY OPTION. - -— \ 1N BASEPAN SUPAIRPLY 26-5/8 FITTINGS FOR ONLY M. Y. 8Z ARE PROVIDED `` __ ix 16751 SUPPLY i AIR 1008A00/ PROVIDES 3/4' EPA THRU CURB 14-I12 [369I 12-1/2 II-1/2 - FLANGE B FITTING [3181 . SEE THRU ART X - 1293] T RASE CHART [60 3-1/4 - 6-1/4 10-I/A- 2X 3/4 — [611 [1581 [256] 16037 F 4 4.- FLUE 12-1/8 .� 1'011 HOOD 13071 K L 2X 25 - I8-3/8 —► [6351 [4661 I 2X 4 5/8 TOP 11181 E STD. /8 t . CONDENSATE 10 107 7/ DISCINICAL DRAIN , 1251 - _._ _ DISCONNECT _ _ -- - .- • •�s • • • LOCATION • 1 FILTER CONDENSER A,B,G OPTIONAL 1 CONTROL BOX 25-3/d COIL I, FACTORY ACCESS PANEL 17-3/8 II[653] INSTAL LED INDOOR BLOWER [d41] AE TURN I il DISCONNECT ACCESS PANEL SUPPLY AIR -- 11 OPTIONAL ( I AIA 'INSAAL�LD ' D J �—CONVENIENCE �. �OUTtCT _ -HANDLE il-7/B I1211/41 D2I 15391 OU FSIDOI J 19-if2 _' [d9d1 - ., C _� �_L_�—ill AIR J _ .�M� 65/8 i HANDLE y ii-i/d .i 12871 .4�� ..�_ua 00 ��..�.— [1681 1 1 5-461 NM 6-1/8 'mu 5-3/4 3-3/4 �4 46-5/8 - _1 -, [21418 3/8 11461 11511 (1171 11461 [951 111861 �- 30-1/8 - I2141 26-7/8 17661 [6821 IF LEFT 74 891 F18897 [7861 BAROMETRIC RELIEF FLOW FRONT SUPPLY ir At RETURN RIGHT AIR ITC CLASSIFICATION I SHEET DATE SUPERCEDES 48FC 04-07 SINGLE PACKAGE ELECTRICAL U.S. E; CR OF 3 09/07/18 06/22/18 COOLING WITH GAS HEAT Packaged Rooftop Builder 1.57 Page 5 of 36 • Certified Drawing for RTU-4 Project: - Untitled271 02/22/2021 Prepared By: 02:22PM -- (ems 1n !,"!;T Is THE Ig[r oT arz c 4N`, .:;;1`s su a {61 a s1 14F rr CONTENTS IS oaLVEACo AlA/ //EFFOFSs coxonlox ��SSHo�ACCCEEPTANCECOF OON1RASI wpNcc ou" STD. UNIT CORNER CORNER CORNER CORNER \ WI14 Nr WRITTEN CONSENT xoT c nl sclosLo OP USED ACCEPTANCE or coxs aA<1. UNIT WEIGH( + WEIGHT(A) WEIGHT IB) WEIGHT ICI WEIGHT ID) C.G. HEIGHT 4Y M„ W1(uoul xq ITTEx coxs[er_ LBS. KG. LBS. KG. LBS. KG. LBS. KG. LEIS I KG� % Y Z 481C++04 482 219 113 51 116 53 128 58 125 57 37 5/8 19561 24 9/16 T5241 18 1/4 T4641 48FC+•05 543 246 138 63 133 60 133 60 138 63 36 1/2 19271 23 3/8 [5941 18 34571 48E0+06 556 252 142 64 136 62 136 62 142 64 '-336 1/2 19271 23 3/8 15941 18 14571 48FC++01 607 215 162 73 152 69 141 64 151 68 36 19141 22 1/2 15721 19 3/8 14921 + STANDARD UNIT WEIGHT IS WITH LOW GAS TEAT AND WITHOUT PACKAGING_ FOR OTHER OPTIONS AND ACCESSORIES. REFER TO THE PRODUCT DATA CATALOG. BACK R1 Z 1/2 WITH ECONOMIZER BACK [3181 t .— — -. WITHOUT CORNER A ORNER 0 ECONOMIZER ECONOMIZER HOOD OPTIONAL DOOR (OPTIONAL) _.__..___._- SWI NO 0 (-- --------:"..:- \ ���u�����i►�I� K 7447-7: Altib�� RIGHT� it «< CORNER D CORNER C — LEFT x 1 TOP — I4 5/8 11e961 f RON O11s -- id i : 1 ... 7 FOR A.. uI K II,Uu AR 4' SERVICE WITH.CLEARANCE WITH. OPERATING CI SURFACE T CONDUCTIVE BARRIER NONCONDUCTIVE BARRIER CLEARANCE 00 i__ �["'-'�I — FRONT - - - LEFT Mm>'stA FRONT BACK , m" "', BACK W/HOOD 'i.; -.. I .,,?; RIGHT :. '=a 1I ,... TOP .." a.. ,: mom} ,,s ITC CLASSIFICATION t ,4 U.S. ECCN.NOR 2 Of 3 3 '��� W - Packaged Rooftop Builder 1.57 Page 6 of 36 Certified Drawing for RTU-4 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM �ClT1lCr IRI TT,Ca' 0.gn I M.`,`",,Vs`, EMArz c11%sm sm x Coo PsTA C1 •, e- -,„,1 1HAT EDF CON NFNOT Of DCLOSDoaNS O ACCEPTANCE Of CO,'F OIi/T��. WIIu011 N1I1lA CONTENTS , 11-1/B - - -1 11805.31 (INSIDE THE BASE RAIL 8 WWI. • d.. _ 1 11 „, 0 (INSIDE THE BASE RAILS) 1 ___,...i....- i �. I k II jram i —_ _. _ 1 1 1, [571 1/4 j' INSIDE BASERAIL DIMENSIONS III [4 61 BOTTOM m I) f r2X 1-3/B 2X 1 [361 [251 3 1/4 [821 2X 3/4 3-7/8 1181 DETAIL C [991 IYP 4 PLCS i • FILTER ACCESS PANEL COMP. CONDENSER CONTROL BOX INDOOR BLOWER (TOOL-LESS) ACCESS COIL ACCESS PANEL ACCESS PANEL PANEL • - 1. • • INDOOR C011 III --SEC DETAIL C ACCESS PAN. - - = ON. • I-l l 8 L-_1 - - O `\ [47.6] x o s i • -- •. (..�= i- ``' . •i obrI E min Amin j n0 i l =- i 1,Uo: ) BACK LEFT 3-1/4 --. L. — --- 59-3/8 y� �__ 2-3/a 182.01 [1509.01 161.51 /-1/8 - - TOP CURB FRONT [18 WIDTH ITC CLASSIFICATION SHEET [.IIE SUPERCEDES 48FC 04-07 SINGLE PACKAGE ELECTRIi.^ ALA s HEAT 1T0003093 Pool TN6 WITH GA U.S. FUN:NSR 3 OF 3 09/07/18 06/22/18 Packaged Rooftop Builder 1.57 Page 7 of 36 Performance Summary For RTU-4 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Part Number:48FCDA06A2A5-0A0A0 ARI SEER: 14.00 Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.6 in Unit Height: 33.4 in Operating Weight Base Unit Weight: 556 lb Total Operating Weight: 556 lb Unit Unit Voltage-Phase-Hertz: 208-3-60 Air Discharge: Vertical Fan Drive Type: Direct Actual Airflow: 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB: 59.3 F Evaporator Leaving Air WB: 57.7 F Evaporator Leaving Air Enthalpy: 24.85 BTU/lb Gross Cooling Capacity: 59.31 MBH Gross Sensible Capacity: 44.73 MBH Compressor Power Input: 4.14 kW Coil Bypass Factor: 0.163 Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 95.0 F Gas Heating Input Capacity: 67.0 MBH Gas Heating Output Capacity: 54.0 MBH Temperature Rise: 25.0 F Thermal Efficiency(%): 81.0 Supply Fan External Static Pressure: 0.75 in wg Fan RPM: 2222 Fan Power: 1.18 BHP NOTE: Selected IFM RPM Range: 1478-2390 Electrical Data Voltage Range: 187 -253 Compressor#1 RLA: 16 Compressor#1 LRA: 110 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 8.6 Combustion Fan Motor FLA(ea): 0.48 Power Supply MCA: 31 Power Supply MOCP (Fuse or HACR): 45 Disconnect Size FLA: 30 Disconnect Size LRA: 126 Electrical Convenience Outlet: None Packaged Rooftop Builder 1.57 Page 8 of 36 Performance Summary For RTU-4 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM Outdoor Fan [Qty/FLA(ea)]: 1 /1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 94.0 90.5 85.6 125 Hz 85.5 81.3 84.7 250 Hz 79.6 73.0 80.5 500 Hz 75.6 68.2 76.0 1000 Hz 72.7 69.9 72.4 2000 Hz 70.1 61.4 68.0 4000 Hz 65.7 54.6 62.8 8000 Hz 61.2 48.6 59.3 A-Weighted 79.2 73.8 79.0 Advanced Acoustics 1114 tit I . 141I ; rt,6 01. i Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 Lp D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp ID A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.57 Page 9 of 36 Performance Summary For RTU-4 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve 3 : iiu_iiunii il ci 21 :4.�-:., 11111111114 urigilil ..-18 T. N 15 . 12 :::i ► \ ►a. ► "' ce . -..„ . 11 P soeH g.,101. - -'1 03 rellibiPild%CO _--�..�/�� I I 1 I I I 1 I m 02 04 C6 08 1D 12 14 15 18 2D 22 24 2& 28 3) Airflow(CFM-thousands) RPM=2222 BHP=1.18 Maximum RPM=2836 MaximumBHP=5.00 SC-SystemCu►ve RP-RatedPoint Packaged Rooftop Builder 1.57 Page 10 of 36 Unit Feature Sheet for RTU-4 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM Carrier Weat erM ker - 48FC PACKAGED ROOFTOPGASHEATING/ELECTRICCOOUNG UNITS- 14SEER3,4,5TONS,15IEER 6Ton STANDARDFEATURESINCLUDE: 0 Puron(R-410A)HFCrefngerant 0 MeetsarexceedsASHRAE90.1 enercgyeffidencylevels Sanlloompressaswilhintemallinebreakandovenoadprotecton Single-stagecooingcapaaty04-06models,TwoStageon07models ' 0 SEERsto14.0,IEERstc15.0 Acutrolrefngerantmeteringsystemon0406models,TXVon07 s¢emodels Exdusivenon-conosivectompositecondensaiepaninaccorciancewith � Y� s ASHRAEStandard62,slopingdesign,sideoroenterdrain Standard000lingoperalionupm115°F(46°C)anddownto40°F(4°C) downto25°F(-4°C)wt hwinterstartkit. Prepaintedextetiorpanelsandpnmer-0oatedintenorpanelstestedto 500hourssattsprayprotecton 0 Fullyinsulatedcabinet NEWDirectDrive-EooBlueTechnologyIndoorfansystemuses VaneAnalfandesignandeteclonicafycornmutatedr r RRu O NewUnitControlBoardwtliinfl 1vequidcfanspeedac uslment • in it' Ptirort0 ExclusiveIGCsdid-statecontrdforonboarddiagnosbcswtlhLED errorcodedesignation burner control logic C r MP r, 0 Induceddraftgasheatcornbustiondesign Redurdantgasvalveswilhuptotwostagesofheatng 0 Lowpressureandhighpressureswilohpmteded. MAINTENANCEFEATURES: 0 Acrpsspanelswitheasygrphandes INEAll-EFIWNEfEEFIES0Innovativeeasystartng,no-sbpscrewsonunitac scpanels 0 Two-indidisposableretumairfiftersardTodgessfitteraccessdoor electrt 0 Newunitcontrdboardtofadlitatesimplesafetydreuittroubleshootng Rion andsinplifiedoontrdboxarrangement (R-410)reftigarantlhetritsarefactcrytesteinboth hezinga thx*grnodes3rtonrnozkisusesi INSTALLATIONFEATURES: slagecccingwritycontrolStorrnxleage 0 Thru-theboitompowerentrycapabity y 0 Singlepantgasandelectricconnedions ocorngcapacit0 Full perimeterbase railwith built-in rigging adapters andforkslots 0 Rekiconvertiblefromvertcaltohorizontalairfiow STANDARDWARRAN1Y: 0 10-yearheatexdianger-15 yearstainlesssteelopton 0 5-yearcompressor Apamect@n tfie: 0 3-tearSystemVu 0 1-yearparts 0 Manyoptionalupgradesalsoavaikable Aettila C it#f6tiO.• OPTIONS INCLUDE BUT ARE NOT LIMITEDTO: • InteligentSystemVuoommunicatngcontrds C • RTUOpenMult-PratocolDDCContrds US ▪ SupplyandRetumAirSmokeDetedors,highstaficmotors • Louveredcondensercoilguards • Discomedawitchardconvenienceoutetoplioru • Stair lessSteelheatexdiangeroption • Corrosionresistantooilcoating. • MERV-8RetumAirFtters • PatentedHumidi-MiZer 'adaptivedehumidificationsystem. • Hingedacraccpanels • Integratecteconomzersystem.LowandUltraLowLeakversions • PhaseMonitorProtecion • CondensateOveflawProtedon ForacompletelistofoptonsandaccessoriesrefertotheProdudData Catalogforthisunit. Page 11 of 36 Packaged Rooftop Builder 1.57 RTU-1,5 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM RTU-1 ,5 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.57 Page 12 of 36 dmr�rirrl► Unit Report For RTU-1,5 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Unit Parameters Dimensions (ft. in.) &Weight(lb.)*** Unit Model: 48FCEA06A2A5-0A0A0 Unit Length: 6' 2.375" Unit Size: 06 (5 Tons) Unit Width: 3' 10.625" Volts-Phase-Hertz: 208-3-60 Unit Height: 2'9.375" Heating Type: Gas *** Total Operating Weight: 574 lb Duct Cfg: _ Vertical Supply/Vertical Return Medium Heat *'* Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are Standard One Stage Cooling Models provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size: 1/2 Condensate Drain Line Size: 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity: 2 Return Air Filter Size: 16 x 25 x 2 Unit Configuration Direct Drive-EcoBlue- Medium Static Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48FCEA06A2A5-0A0A0 Rooftop Unit 2 Base Unit Direct Drive-EcoBlue-Medium Static None Packaged Rooftop Builder 1.57 Page 13 of 36 Certified Drawing for RTU-1,5 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM 1 H15 DOC UN(NT IS THE PROPERTY Of RIC CTIM TT IOMiROLS SIIBNISSION OP -S ON DOCDWENTS NOTES — - n l.lf�iG/�dNA7tURIlY nxD IS DELIVERED IIiOx TILE C E C.°'—N S NOT CONS PERFORMANCE ON UNIT J K ` IRE CONTENTS WILL NOT BE DISCLOSED OR USED ACCEPI4NC JNIRACT. • 1. DIMENSIONS ARE IN INCHES, DIMENSIONS 33 318 TA 518 14,.......,........... WIINODI WRITTEN CONSENT IN [ 1 ARE IN MILLIMETERS. dBFC+N04 [8411 [4721 2. 33 3/8 I4 770 CONNECTION SIZES 60 CENTER 0E GRAVITY 48FCAA05 [8471 [377J __ 33-3/8 A 1 3/8" [351 DIA FIELD POWER SUPPLY HOLE 48FC3•06 33 3/8 14 7/8 18481 - 3. DIRECTION OF AIR FLOW [8471 I3771 9 2" 1501 DIA POWER SUPPLY KNOCKOUT 48FCAA07 41 3/8 IB SIB 32 1/8 --- --— C 1 3/4" [DTI DIA GAUGE ACCESS PLUG [10511 14721 ' ECONOMIZER HOOD 4. ALL VIEW DRAWN USING 3RD ANGLE [8171 TOPTIONALI 16 _. D 7/8' 1221 DIA FIELD CONTROL WIRING HOLE_ 5 /1 8 -+• I4071 E 3/4"-1 4 NPT CONDENSATE DRAIN IN 1/2" 14 NP7 GASCONNEGTION RETURN AIR ' G 2 1/2 " 1641 DIA POWER SUPPLY KNOCK OUT i HAU-THE-BASE CHART iii THESE HOLES REOUTAED FOR USE I277/8 RETURN E HOLES RA00. 009A00 I IQ�1j�ltilI THREADED WIRE REO'D HOLE .� �II"`��,�ll`l`�E\ /%� y�/' r. CONDUIT SIZE USE SIZES (MAX I- ��` � " " W 1/2' ,15V� 7/8" [72.21 X 1/2' 24V 7/8" l22.21__ '.; ems/ Y 3/4' POWER 7-1/8" [28.61 1112044 891 \� 29-112 -�. Y E ALT. f7481 - - W CONDENSATE 17 34 Ix 1009A001 1/2" OPT GAS 1-1/8'_[28.61 I 1 DRAIN OPINING OPTION.---- 1N BASEPAN SUPPLY FOR "TNAU-THE-BASEPAN" FACTORY - ---- AIR 26-5/8 FITTINGS[OR ONLY X. Y. 1 Z ARE PROVIDED 1575, SUPPLY 14 1/2 } 1 i AIR A 1008A00) PROVIDES 3/4" OPT THRU CURB [36,)] 12-I/2 11 la - SEE TORE THE_;N _k I FLANGE 6 FITTING [3 Ri] 1231 1 ' BASE CHART - - 10-1/8- f— 2k 23-3/4 - 3-I14 --- --- - 6-1/3 12561 16031 �� fall 1581 4 F 12 71 1/8 LUE [101] HOOD 130 r N L ,N ,5 14-318 —.- A 16351 [4661 4-s18 TOP 11187 SAD CONDENSATE 10-1/8 1 ELECTRICAL DRAIN [2751 I251 - -. DISCONNECT _.. _ . - LOCATION A ... -FILTER CONDENSER 'Mn A,B,G OPTIONAL ' CONTROL BOx •I� COIL FACTORY ACCCSS PANEL (6531 3/d INSTALLED INDOOR BLOWER 17-318 �II L4411 DISCONNECT ACCESS PANEL ETURN OPTIONAL 1 / SUPPLY AIR AIR FACTORY gu iD --_--I _� �, ral ( ( n� INSTALLED �' CONVENIENCE OUTLET ' HANDLE 11-7/8 I 21-1/4 13021 19-1/2 ��' J/ I I (539I OUTSIDE .., - 1 f 4947 'S l 1 1 • �� AR J L �� 11-1/4 Y _ 0 4101 0 I/VAI 1 1 .°100 .m.a.... NM 0ON M� . J - - _HANDLI 5-3/4 OM 6-3/8 3/4 3-314 l� -- 5/8 y 1 [[2148 11441 7[1fi1] [I771 11461 C 95] -�a61 - 30-1/8 .. 26-7/8 -y I7661 v... _ 31 J f6821 LEFT 4nao [7867 BAROMETRIC RELIEF FRONT SUPPLY FLOW At AIR RETURN RIGHT AIR CLASSIFICATION SHEET DATE I SUPERCESIS I 4/F1 H4 IT SING]E RAcRAGE ELECTRICAL REV S. ECC N:NSR 1 OF 3 - - 48TC0030A3 A Packaged Rooftop Builder 1.57 Page 14 of 36 Certified Drawing for RTU-1,5 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM Carder THIS DOCD T IS THC PAOPCATY OF UIC CLIMATE.CONTROLS SggNSS0'OF THESE DRAWIN65 DA AIXDNCNTS —-- -- t l.a {� TBATIRE CONTENTS IS WITT 1 E DX TLC CFPXESS(OND1ilON [ 1 tOX5T 1T11TE GAA1 VCAt OANAx<C OA STD. UNIT CORNER CORNER CORNER CORNER C.G. HEIGHT \ IRE caxT[xr3 WILL NOT BE DISCLOSED 04 USED ACCEPTANCE OF CONTRACT. UNIT WEIGHT N WEIGHT (A/ WEIGHT /01 WEIGHT ICI WEIGHT (01 pA..,Nr,xA,—," v[TuouT WR1TrIl+coxsExT. LBS. NG. LBS. KG. LBS. KG. LBS. KG.. LBS. KG. A Y Z 48FCN404 482 219 113 51 116 53 128 58 125 57 37 5/8 1956] 24 9/16 16241 18 1/4 14641 48FCNN05 543 246 138 63 133 60 133 60 138 63 36 1/2 19271 23 3/8 1594] 18 14511 48FC..06 556 252 142 64 136 62 136 62 142 64 36 1/2 [927] 23 3/8 1594] 18 14511 48FC4401 607 215 162 /3 152 69 141 64 151 68 36 (9141 22 1/2 15721 19 3/8 14921 . STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. I RACK R 1 2 1/2 WITH ECONOMIZER BACK F3181 , • WITHOUT CORNER A CORNER 8 ECONOMIZER ECONOMIZER HOOD OPTIONAL DOOR IOPIIONALI ' -__.. - e __. )/ _ _.._`-` — SWING O it % RIGHT nd1111V11111,. of-��� • • CORNER 6 — — CORNER C �— LEFF — — I � a I L. X — TOP 118961 F RON T 1 i I oF9 __ _ 1. FOR ATI MI N I WOW CI[ARR.-DB LOCAL l0 .,c T,CT IONS MAP OKRA:. P / CLEARANCE — 3 _ _11 SERVICE WITH SERVICE WITH OPERATING _ [� 1 SURFACE CONDUCTIVE BARRIER NONCONDUCTIVE BARRIER CLEARANCE u FRONT z 9m - HP�� E� I �_ LEFT 4k 19mm BACK 48 I T D I HTTff FRONT •___BACK W/HOOD 36 914mm _J- RIGHT j 36 `914omi I , TOP I 7' E1829mr) ITC CLASSIFICATION SHEET f [,A'3 U.S. ECCN:NSR 2 OF 3 '" -- - Packaged Rooftop Builder 1.57 Page 15 of 36 Certified Drawing for RTU-1,5 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM g/•�i // HIS UO(IIM(' IS I PRO T"0�I�C f`,4 f ,,IP012 suov;,10X Of 1HE5[DR AMT OR DOC UYExIS l.(f' i� A �CNxI TY RNp IS Of LIYf ACD IIPOH TNC CYPRESS CONDITIOX S XOl CCERTANCt PAAi TRACT xI.xCC OP C X*[NTS NEl XOl xE DI SCl05(D OR NRCD xC<EPi ANCE CA COxTR.1(T. 0 N�xlTwx�1� YIINODT YxI1iCN CONSENT. _____. __—__ ___ 71-1/8 / I1805.31 7 (INSIDE THE BASE RAIL 8 SNIRTI ri „T„,.,...,4;'''''''' 1. --T-T „ — 41-1/4 0 (INSIDE T1HE BASE RAILS) :....................,..;8,...•,,,_."-- -.-''''-',.Tor- 111 �� ' � INSIDE BASERAIL DIMENSIONS APPPAII ' 2% 19614 BOTTOM % [neiB -T„-- , , i i,,, , i 111M-2911E4 'a 2% 1-3/8 2% 1 — 3-1/4 [361 1751 E827 _. t— 2% 3E4 3-TIE 1181 DETAIL C L991 TYP 4 PLCS 1 FILTER ACCESS PANFI COMP. CONDENSER CONTROL BO% INDOOR BLOWER (TOOL LESS) ACCESS I COIL _ ACCESS PANEL ACCESS PANEL . PANE( o IND0011 cr' I SEE DEIAIt C BCCFS` _ - __ _ • 7 r E� _ - • p I-718 9 :0"_1 i I 1 i . ]+ I I- ' I. I` ) - i`1 LI4, 61no I L� IL-��I l_J 1 Ala BACK LEFT 3 1/4 -- 59-3/8 � 182.01 11509.01 7-1/8 -+ 161.SI t 180.7I TIP CURB FRONTWIDIH ITC CLASSIFICATION SHEET DATE SUPERCEDES 481C 04-07 SINGLE PACNAGE ELECTRICAL REV U.S. ECCN:NSR 3 OF 3 1 09107/10. 06/22/18 COOLING WITH GAS HEAT 48T0003093 A Packaged Rooftop Builder 1.57 Page 16 of 36 Performance Summary For RTU-1,5 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Part Number:48FCEA06A2A5-0A0A0 ARI SEER: 14.00 Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.6 in Unit Height: 33.4 in Operating Weight Base Unit Weight: 511 lb Medium Heat: 63 lb Total Operating Weight: 574 lb Unit Unit Voltage-Phase-Hertz: 208-3-60 Air Discharge: Vertical Fan Drive Type: Direct Actual Airflow: 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB: 59.3 F Evaporator Leaving Air WB: 57.7 F Evaporator Leaving Air Enthalpy: 24.85 BTU/lb Gross Cooling Capacity: 59.31 MBH Gross Sensible Capacity: 44.73 MBH Compressor Power Input: 4.14 kW Coil Bypass Factor: 0.163 Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 110.7 F Gas Heating Input Capacity: 110.0 MBH Gas Heating Output Capacity: 88.0 MBH Temperature Rise: 40.7 F Thermal Efficiency(%): 80.0 Supply Fan External Static Pressure: 0.75 in wg Fan RPM: 2222 Fan Power: 1.18 BHP NOTE: Selected IFM RPM Range: 1478 -2390 Electrical Data Voltage Range: 187-253 Compressor#1 RLA: 16 Compressor#1 LRA: 110 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 8.6 Combustion Fan Motor FLA(ea): 0.48 Power Supply MCA: 31 Power Supply MOCP (Fuse or HACR): 45 Disconnect Size FLA: 30 Disconnect Size LRA: 126 Packaged Rooftop Builder 1.57 Page 17 of 36 Performance Summary For RTU-1,5 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM Electrical Convenience Outlet: None Outdoor Fan [Qty/FLA(ea)]: 1 /1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 94.0 90.5 85.6 125 Hz 85.5 81.3 84.7 250 Hz 79.6 73.0 80.5 500 Hz 75.6 68.2 76.0 1000 Hz 72.7 69.9 72.4 2000 Hz 70.1 61.4 68.0 4000 Hz 65.7 54.6 62.8 8000 Hz 61.2 48.6 59.3 A-Weighted 79.2 73.8 79.0 Advanced Acoustics �., F a . Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 Lp D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.57 Page 18 of 36 Performance Summary For RTU-1,5 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve �- �2�ooRPM 27 24 H - 3.0061IP • 21 2300pPfv1 18 ' 2100RPM w 15 19006121M d _ 12 vcoRPM to P w -1300RPM _1100MA 1.. BHP 900Min/ 9 1.00: • Q3 0.50BHP CO I I l I I I CO 02 04 06 CB 16 12 14 16 18 20 22 24 26 28 30 Airflow(CFM-thousands) RPM=2222 BHP=1.18 MaximumRPM=2836 MaximumBHP=5.00 SC-SystemCurveRP-RatedPoint Packaged Rooftop Builder 1.57 Page 19 of 36 1 Unit Feature Sheet for RTU-1,5 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Carrier ather er -48FC PACKAGED ROOFTOPGAS HEATING/ELECTRICCOOUNG UNI TS- 14SEER3,4,5TONS,15IEER 6Ton STANDARDFEATURESINCLUDE: 0 Puron(R-410A)HFCrefrigerant Meetsorexce ASHRAE90.1 energyeffiderxylevels r 0 Sadloorrpressorswilhintemallinebreakandoverloadprotection 4 S�nglest�jecodingcapadly04-06models,TwuStageon07models 0 SEER'sto14.0,IEER'sto15.0 5,71 9 AafioY-eirigerantmeteringsystemon04-06models,TXVon07 f sizemodels r, % wd` 9 Exdusnre naocadancewith = ,,<0 41/f f >. t ASHRAEStandard62slopngdesign,sideorcenterdrain Standardcodingoperationupto115°F(46°C)anddownto40°F(4'C) downto25°F(-4°C)w ithwinterstartkit. 0 Prepaintedexteriorpanelsandprimercoatedinteriorpanelstestedto 500hourssaltsprayprotedion Fullyinsulatedcabinet NEW DiredDrive-EcoBlueTechnologyIndoorfansystem uses H�A E VaneNdalfandesicyandelectroncallycommutatechrrutor NewUnitConhnlBoardwilhintui6veguickfanspeedadjustment P f')f 0 ExdusivelGCsolid-statecorrtrdforon- oarddiagnosticswithLED COMPLIANT errorcodedesignationbumercontrdbgic Induceddaftgasheatoombustiondesign 0 Redundantgasvalveswithuptotwostagesofheating Lowpressureandirghpressureswitchproteded. MAINTENANCEFEATURES: Aocesspanelswitheasygnphandles VEATHERMKEFEITES El Innovativeeasysfarting,no-stipscrewsonunitacoesspanels Two-inchdisposableretumairfiltersandTooNessfitteraa-scdoor Newunitconfrdboardtofac itatesimplesafelydreuittroubleshooting CCdrgritstiatarepre-vieedatchatgaintiFUrn andsimplifiedcontrdboxarrangement (R-410)refticpantTheutsarefactaytestedinboth heatirgaidcozin ip ;3-5 INSTALLAT1ONFEATURES: Thn-thek:ottompowerenryc pabilily � ot Singlepdntgasandeledricconnections 0 Fullperimeterbaserailwithbuitt-inriggingadaptersandfotkslots 0 Fieldconverhblefromverlicaltohorizontalairflow STAPDARDWAf ANTY: 10-yearheatexchan der-15-yearstainlesssteeloption �� 3-tea Syst�V 1-yearparfs r:' &4 12F11 Manyoptionalupgradesalsoavailahle OPTIONS INCLUDE BUT ARENOT LIMITEDTO: �� • InteligentSystemVucommunicalingcontds C GIs!) • • RTUOpenMulti-ProtocolDDCContrds • SuppyandRetumAirSrrakeDetedors,hghstaficmotors • Lcuveredcondensercoilguards • DisconnedswitchandconvenienceouNetoptions • Stair ir Steelheatexchangeroption • Corrosion resistant coil coating. • MERV-8 Return Air Fitters • PatentedHumidi-MZer �'adaptivedehumidificalionsystem. • Hingedacr sspanels • Intryratddeconornizersystem.LowandUliraLowLeakversions • PhaseMonitorProtedon • CondunsateOverflowProtedion ForaoompletelistofoptionsandaocessonesrefertotheProductData Catalogforthisunit. Packaged Rooftop Builder 1.57 Page 20 of 36 RTU-2,3 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM RTU-2,3 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.57 Page 21 of 36 Unit Report For RTU-2,3 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Unit Parameters Dimensions(ft. in.)&Weight(Ib.)*** Unit Model: 48VL-C480905 Unit Length: 4'0.1875" Unit Size: 48 (4 Tons) Unit Width: 3' 8.125" Volts-Phase-Hertz: 208-3-60 Unit Height: 4'4.75" Heating Type: Gas *** Weights and Dimensions are approximate.Weight does not include roof Duct Cfg: Vertical Supply/Vertical Return curbs,unit packaging,field installed accessories or factory installed options. Approximate dimensions are provided primarily for 90,000 Btuh shipping purposes.For exact dimensions and weights,refer to appropriate Standard Unit product data catalog. Total Operating Weight: 438 lb Warranty Information 1 year warranty on parts 5 year warranty on compressor 5 year warranty on heat exchanger No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48VL-C480905 Rooftop Unit 2 Base Unit Packaged Rooftop Builder 1.57 Page 22 of 36 Certified Drawing for RTU-2,3 Project: --Untitled271 02/22/2021 Prepared By: 02:22PM 0111 ELECT%Hal Olt 1T e41T Can I4+7R+ CE8TE4 0 5544I17 PIN*-. 13-15E14 w- 13-16E16 �- CHA8KtE8IS1It3 Le 4G 'A• 3 T 2 1354.e1 1354 al 6e011-A S04240463030 s13t 5376 tae3236-1-60„20e3230-3-61.460-3-60 415 1186 44-334 1+37 22-13n6 574 A to 4V.2 +1-13 433.0 3-1414-.. r f39ti6 44v1(-r11C4a10627*157x30u3r3tbsa 2a3t230-3-41.201t231-3-60,46a-3-4O 434 ,331 41-314 *313 ??-13416 St!.4 34 457.3 11-L! 441,3 [at sl tiu.31 lir ill4a"3Li-i4s{{010}1ts1571)1i(375t6)0 2083234-z-61,21e/23a-l-ie,,64-3-81 455 186 6 54-37e :36? 22-1)ttf 514.4 to 45'.2 1t-54e /,i.l 2-13.1 CI 1ETa14 ; Sy14L3 VI 41 eA yell vq-1KE <OW 4E161T1 Lat46 2. y ,. l 3-=- l2 3341330ai0 bib 24 t 63 3 37 S 121.3 38 t s446 45.4 O4TIIy1N 46 I�7234t414,13.I 24 8 87.6 )1.1 131 4,41e. '-51.3,63.A ;'y OlT[Cw+L SW4L3 68 200+I387448 44.3 33 4 3,,0 Al 5 tp.5 613 `•331 12.2 4CT1Fr AIR 14.75n6 WI O4EM% U14 p II{ Nall do ,or. s Ifs GAMS 14 C 2 MA (n,�t1�ti�tt��`. c t 411 ('41 to41 1 1:' • TOP O3 MT 14 C353 61 'J% ■ COT 516E Ot tilt ES#.II 00TO0O0 COIL-'" : f 3-3rtt 311E 01MSITE 6II . .. 1 Ct55.41 Itt ` ?O1 a0TT04 OF xaIT 1t?.1)i •oII.42 3 it Ili M01/�tIf91CMlta MKS t411 'Ii �.cF ',r 16-13116 4E11HN 181TS. F teett 3I31 42 11361 62 -. Z t 1173 DI *IT w*4 ILO*OR tO40 777*LL3 AO"NE.i E 33 [4N 11 0 1 MAHE0 16MKE3.80E1 NIP linn. I?21064.41 * I GlIINIR16 l4411 LM =NO NOMA t Eve 3011*CM SIBS 1IIT 144 Cfil 00) TOP VENT MT ttEEHrt4FPI FOR*PPREOLIPE.k.I 43 1/444.41 *IT TOP... .. .... ....._48 13217 21 31N W3O311E ToTT3. 34 CIII 01 OCT P4111 t2 C334 114 lir HOW*0131A43E3-IE OTT II e173E1 LESS TAA4 tt C31I II T004*LT 1•STE4,T3E4 1I77E4 41-7516i Al 111 464T E wilt [3Ee. cc*cc*61 2 ryn 11 111 [+u 71 aT4E4SIoxs Ia 11 A t4M [ss A) 1 1 IlIllIllIllIllIl � { 2ii -�IIII IIIIIIIIIIII +-+ra'I21.41 41a. AROOD .' """"""""It, ' 1 1111111111 1111111 IlhhhiOlUilIlI .IIIIHIHIIIHIDI: t us' 122.11 0I 811T E I1HHIllIOhhIhhfl .....:""'�1"' 1""�' 4 7 a t11 01L EHPLE I t,zi 41 1 MI = 1 111111 - ,5-1,1 at�.hIll �III 7=rai • (407 21 Ea,:11t-17a11 - a[xl II 1 •,, .3 41• C545 62 t7-Sta /it - tilt%tl 1441 H +37,8 31a ' a 6-Sta E 0 -��� O � 1111 =6� • -•�• -�= �Ii1L� = n6e 31 01AI4%TLC C04P4IS41•` 70011 5-4/16 3'4•I,3.114..7 61. P44EL 1 4t,31 , ,,2'E11 II M P T 3t+4 '2-tl%13 .A*E1. 6 3 Ix1x* 3-3re 13-3ta 4 71e•I22.11 eEf4 1328 6) 143 71 2.1n6 11 13 I6'.SI 13N.1 44-1,6 C43.71 U-3tri CS?II I„<,nI 11 PH 01 '713t16 13-741 13.771 LEFT SIDE VIEW FRONT VIEW f44 07 RIGHT SIDE VIEW 1s52 a �� VEw 1332 41 I4avLsoo4os J I Packaged Rooftop Builder 1.57 Page 23 of 36 Performance Summary For RTU-2,3 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM Part Number:48VL-C4809O5 ARI SEER: 14.00 Base Unit Dimensions Unit Length: 48.2 in Unit Width: 44.1 in Unit Height. 52.8 in Total Operating Weight: 438 lb Unit Unit Voltage-Phase-Hertz: 208-3-60 Air Discharge: Vertical Fan Drive Type. Direct Actual Airflow: 1660 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB:_ 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB:. 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB: 60.4 F Evaporator Leaving Air WB: 58.3 F Evaporator Leaving Air Enthalpy: 25.23 BTU/lb Net Cooling Capacity: 46.37 MBH Net Sensible Capacity: 35.16 MBH Total Unit Power Input: 4.04 kW Coil Bypass Factor: 0.054 Heating Performance Heating Airflow: 1660 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 110.7 F Gas Heating Input Capacity: 90.0 MBH Gas Heating Output Capacity: 73.0 MBH Temperature Rise: 40.7 F AFUE (%): 80.4 Supply Fan External Static Pressure: 0.60 in wg Options/Accessories Static Pressure Wet Coil: 0.10 in wg Total Application Static(ESP + Unit Opts/Acc.): 0.70 in wg Fan RPM: 1075 Fan Power: 0.52 BHP Fan Motor Size, hp: 1 NOTE: Medium Motor Speed, Vert Electrical Data Minimum Voltage: 197 Maximum Voltage: 253 Compressor RLA: 13.7 Compressor LRA: 83.1 Outdoor Fan FLA(ea): 1.05 Indoor Fan Motor FLA: 7.6 Power Supply MCA: 25.8 Power Supply MOCP (Fuse or HACR): 35 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Packaged Rooftop Builder 1.57 Page 24 of 36 Performance Summary For RTU-2,3 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM Acoustics Sound Rating: 73.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 57.1 250 Hz NA NA 57.6 500 Hz NA NA 60.5 1000 Hz NA NA 62.7 2000 Hz NA NA 58.2 4000 Hz NA NA 56.4 8000 Hz NA NA 50.7 Advanced Acoustics 1144 1141,„k Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 0.0 57.1 57.6 60.5 62.7 58.2 56.4 50.7 67.2 Lw B - 41.0 49.0 57.3 62.7 59.4 57.4 49.6 66.0 LwA 26.2 C 0.0 24.7 25.2 28.1 30.3 25.8 24.0 18.3 34.8 Lp D - 8.6 16.6 24.9 30.3 27.0 25.0 17.2 33.6 LpA 26.2 Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed Packaged Rooftop Builder 1.57 Page 25 of 36 Performance Summary For RTU-2,3 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.57 Page 26 of 36 • Unit Feature Sheet for RTU-2,3 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM There is no Certified Drawing available for this tag Packaged Rooftop Builder 1.57 Page 27 of 36 RTU-6 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM RTU-6 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.57 Page 28 of 36 Unit Report For RTU-6 Project: --Untitled271 02/22/2021 Prepared By: 02:22PM Unit Parameters Dimensions (ft. in.)&Weight(lb.)*** Unit Model: 48FCEM07A2A5-0A0A0 Unit Length: 6' 2.375" Unit Size: 07(6 Tons) Unit Width: 3' 10.625" Volts-Phase-Hertz: 208-3-60 Unit Height: 3' 5.375" Heating Type: Gas *** Total Operating Weight: 625 lb Duct Cfg: Vertical Supply/Vertical Return Medium Heat *** Weights and Dimensions are approximate. Weight does Single Circuit, Two Stage Cooling (07 only) not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size: 1/2 Condensate Drain Line Size: 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity: 4 Return Air Filter Size: 16 x 16 x 2 Unit Configuration Direct Drive-EcoBlue-Medium Static Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48FCEM07A2A5-0A0A0 Rooftop Unit 1 Base Unit Direct Drive-EcoBlue- Medium Static None Packaged Rooftop Builder 1.57 Page 29 of 36 Certified Drawing for RTU-6 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM q/` rri IRIS DOCr%IS THE PA OPEAIY OF IIIC CLIMAIC CARTRO"5H9AISSION 0E 1HfE DAAWIM0, ADM [TS NOTES. - — a..al//L�t SECUNIir nx0 IS DELI vf�ACO UPDX iNF CYPRESS CONpIiIONS NO1 CON S11i0TE PART [Rl0A M,1FCC OA UNIT J N \ --- THAT LLF CONTENTS Will 1 0E DISCLOSED OA DSED WITHOUT WRITTEN CON., ACCE PI ANCf OF(ORIAACT. 1. DIME NS70N5 ARE IN INCHES, DIMENSIONS 48FC+W04 33 3/1 18 5] 0 RWWwr..r.r. IN [ ] ARE IN MILLIMETERS. [8471 1417] 2 CENTER OF GRAVITY 48FC4W05 33[847 3118 1[314 ll81J _ CONNECTION SIZES ____ 3 3l8 14 778 - 33-3/B A 13/8" C35] DIA FIELD POWER SUPPLY HOLE 3. DIRECTION OF AIR FLOW 48FC+.06 1847] I3771 I8481 8 2" [501 DTA POWER SUPPLY RNOCNOUT d8FC A107 41 3/8 18 5/8 32-7/8 ' C 13/4' [511 DIA GAUGE ACCESS PLUG [10511 1412] ECONOMIZER HOOD 4- ALL VIEW DRAWN USING 3RD ANGLE --- [8171 (OPTIONAL) D 7/8" 1221 DIA FIELD CONTROL WIRING HOLE 16 • [4071 _E 3/4' 14 NPT CONDENSATE DRAIN 25-S18 —� F 1/2' 14 NPT GAS CONNECTION [6521 RETURN AIR G 2 1/2 " 1641 DIA POWER SUPPLY KNOCK OUT rS.. .. .. ..-� • ----- • —_ ( y/�i ��\\\1C- ♦ THRU-THE-SASE CHART 10-1/8 RETURN THESE HOLES REQUIRED 00 FOR USE tl �I��Br.��/�� �\\`1 [2771 AIR CRB4WR008R00 009R00 __ 111,���'��I�I�I f THREADED I WIRE ROOD HOLE � CONDu1T SIZE USE SIZES (MAz.) A���Vo,`-1,.// /_ A W 1/2" 115V 7/8' 122.21 44 -" z 1/2' 24V 7/8" [22.21 1 79891 f • � E ACT. 1 29-12 -r — 3/4" POWER 1 1/8' 128.61 __i. _y [7481 . l CONDENSATE 17-31d 1 [. I009A00) 1/2"FPT I GAS 1-1/8' [28.61 W- 1 DRAIN OPENING 14511 -"--"— i •• - fOH "THRU-TNC-BASE PAN" FACTORY OPTION. i I.�, IN BASEP AN SUPPLY 26-5/8 INGS TOR ONLY A. Y. 6 Z ARE PROVIDED --��I AIR [6751 SUPPLY AIR 808A00) PROVIDES 3/4" FPT THRU CURB 14[36912 12-112 II-1 l2 - / FLANGE 6 FITTING [2831 SEE THRU THE- `--y l ---- - L BASE CHART _- 1 L_ i- -• d� . 1 _+ 10-1/8 I~ 2N 23-3/4 - _ 31/4 - 6-1/4 12561 16031 [81] [1581 FLUE 12-I/8 [1011 HOOD 13071 r N 2S 25 - 18-318 [4661 t E6351 2a 4-5/8 TOP THAT E STD CONDI NSAIF 10-7/8 1 I ELECTRICAL DRAIN 12151 [251 A CONDENSER - II A,8,G OPTIONAL CONTROL BON COIL - FAC 70RY ACCESS PANEL it-3/8 25-3/4 ISCONNECT INDOOR BLOWER I1631 _ DISCONNECT \\\\ ACCESS PANEL [4411 RETURN OPTIONAL �,', { `= SUPPLY AIR I AIR �� j r____„ FACTORY J INSTAV-ED -D 4 CON4LNIENCE - . JUT ET , l, i F�, -HANDLE II-7/8 I I \ 2I 1/4 1 021 i 19-1/2 41 _1 1 [5391 l494] I 4' 6-5/81781114 �_- , � ��.� �� -=-r 11681 l 1 + � `I— 0 0". I -- •E --_ I F 1 J�_ HANDLE-- 5-3I4 NM 6-3/8 7 1. 5-3/4 82141 11461 [1771� 11461 -3/4 -- 46-5/8 30-I/8 _ 8 3/8 26-7/8 111861 [7661 687/ LEFT [18891 31 74 8 BAROMETRIC 17861 RELIEF FRONT FLOW AIR *RETURN i RIGHT AIR ITC CLASSIFICATION I SHEET 1 DATE 1 SUPERCEDES r ( P,A/NAE 8T REV aF_ o4DT s.N,ET LE eLCAE „, Packaged Rooftop Builder 1.57 Page 30 of 36 Certified Drawing for RTU-6 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM IC—Card?T x D £4xDaD RNO m uRn .B ORms selssm a raES DwalNps DR 4s ...TONBOB NOT CONSTITUTE EEORv A E CONTENTS BILL NOT BE DISCLOSED ON USED STD UNIT CORNER CORNER CORNER CORNER ACCEPTANCE OP CONTRACT CG HEIGHT 4,,,,,,r,r,,,,� UNIT WEIGHT . WEIGHT (Al WEIGHT (BI WEIGHT (C1 WEIGHT (D1 - _ LBS. NG. LBS. KG. LBS. NG. LBS. NO. LBS. NG. F Y 7 48FC..04 482 219 113 51 116 53 128 58 125 57 37 5/8 19561 24 9/16 16241 18 1/4 14641 48FC••05 543 246 138 63 133 60 133 60 138 63 36 1/2 19271 23 3/8 15941 18 [45/1 4812..06 556 252 142 64 136 62 136 62 142 64 36 1/2 19271 23 3/8 15941 18 (4511 48SC••07 607 275 162 73 152 69 141 64 151 68 36 19141 22 1/2 (5721 19 3/8 [4921 . STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. 1 BACK R12 1/2 WITH ECONOMIZER BACK [3181 — CORNER A E OINOMOINZER CORNER B ECONOMIZER HOOD OPTIONAL DOOR (OPTIONAL) ' SWING V it \ 1114..6 SWI\Q""1h1' ' ' .1 n1111111111111.� / �ii1� RIGHT CORNER D CORNER C LEFT TOP (18961 RONT ----. ._-. --..._1 i O4 e `�y•.I.c AAAMCFS LOCAL C' ;ti$MA,' 15 VAT._. __ __._-_ CLEARANCE I r) SERVICE WITH. SERVICE WITH. OPERATING — SURFACE CONDUCTIVE BARRIER NONCONDUCTIVE BARRIER CLEARANCE FRONT 00 r 1-^-�I 0o ., LEFT FRONT BACK L BACK W/HOOD RIGHT i---_. TOP ITC CLASSIFICATION SHEET 1 - U.S. ECCN.NSR 2 0f 3 _.-. Packaged Rooftop Builder 1.57 Page 31 of 36 • , Certified Drawing for RTU-6 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM --- -- ` .l{1(IG/.6XS[C,O �[ a 'X:r I iTs FIA�IOX SUBXIS"I�OX Of 5 DOC E 5 XS/ s o oX usEo s Cos Pc roAXn XCE Xi ACCEP�nX JN1 AA<1. O AYWYWT�Ytf WI iNOU�X'v. ,N l.(lxSEXT,77 11'1/8 77 11805 31 (INSIDE THE BASE RAIL 8 SKIRT) \ 1 1f ,R om\\ 41-I/4 \` [10d6,51 =\ U IINS]DE THE BASC RAILS) o � �,� li, �z o � � �I 3/4 1 INSIDE BASERAIL DIMENSIONS ®I AEI BOTTOM 481A i t E _.._ 1.3/8 - ;X _.. 3 1/4 — 7367 [2,1 18?I ••, f_ PX 3/4 - 3-7/8 1181 DETA1: C [991 TYP 4 PLCS EILIER ACCESS PANEL CLAP 1 CONDENSER CONTROL BOX INDOOR BLOWER [TOOL-LE851 ACCESS COIL ACCESS PANEL ACCESS PANEL PANEL 0 iir _ �y INDOOR(OH ( = I. ACCTSS PANT _ _ IN 1!{ -SEE DETAIL C NN BACK LEFT 3-,/4 -~, 2772, [82.01 ',n4 2 3/6 -- [61 P FRONT WIN ITC CLASSIC ICAlION SHEET I DATE SBPERCE DES 481C 04 �'t A(,KAGF f -i A'. RCV 4840003093 U.S. EGCN.NSR__ 3 Of 3 09/01/18 06122/18 C3 NO 8/I7H GAB H,A A Packaged Rooftop Builder 1.57 Page 32 of 36 Performance Summary For RTU-6 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Part Number:48FCEMO7A2A5-0A0A0 ARI EER: 11.00 IEER: 15.0 Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.6 in Unit Height: 41.4 in Operating Weight Base Unit Weight: 562 lb Medium Heat: 63 lb Total Operating Weight: 625 lb Unit Unit Voltage-Phase-Hertz: 208-3-60 Air Discharge: Vertical Fan Drive Type: Direct Actual Airflow: 2400 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB: 58.5 F Evaporator Leaving Air WB: 57.5 F Evaporator Leaving Air Enthalpy: 24.73 BTU/Ib Gross Cooling Capacity: 72.42 MBH Gross Sensible Capacity: 55.62 MBH Compressor Power Input: 5.29 kW Coil Bypass Factor: 0.096 Heating Performance Heating Airflow: 2400 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 104.0 F Gas Heating Input Capacity: 110.0 MBH Gas Heating Output Capacity: 88.0 MBH Temperature Rise: 34.0 F Thermal Efficiency(%): 80.0 Supply Fan External Static Pressure: 0.75 in wg Fan RPM: 2355 Fan Power: 1.39 BHP NOTE: Selected IFM RPM Range: 1596 -2530 Electrical Data Voltage Range: 187 -253 Compressor#1 RLA: 17.5 Compressor#1 LRA: 136 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 4.5 Combustion Fan Motor FLA(ea): 0.48 Power Supply MCA: 28 Power Supply MOCP (Fuse or HACR): 45 Disconnect Size FLA: 27 Packaged Rooftop Builder 1.57 Page 33 of 36 Performance Summary For RTU-6 Project: -Untitled271 02/22/2021 Prepared By: 02:22PM Disconnect Size LRA: 146 Electrical Convenience Outlet: None Outdoor Fan [Qty/FLA(ea)]: 1 /1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 93.5 90.5 85.6 125 Hz 85.3 82.0 84.7 250 Hz 79.6 73.1 80.5 500 Hz 76.9 69.3 76.0 1000 Hz 74.1 71.1 72.4 2000 Hz 72.0 62.6 68.0 4000 Hz 66.9 55.4 62.8 8000 Hz 61.9 49.7 59.3 A-Weighted 80.2 74.6 79.0 Advanced Acoustics ttg 4141 ", ti , 0 i� Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k _ 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 Lp D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.57 Page 34 of 36 tie w Performance Summary For RTU-6 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. ry� Fan Curve 2J 18 • !!- 1s ci14 hihkrL1111 \11111 ��1IIIIII \ u) .1 1 , 1D ._ .1 H.." " w co ,1 is-•,- IIIIIIIIIIIII Il : 1I!UflUpVi OOBHP 04 OZ ,,, CO I 1 I I \ I 1 I I !' - m 02 04 DS 08 1D 12 14 16 18 20 22 24 26 28 33 Airflow(CFM-thousands) RPM=2355 BHP=1.39 MaximumRPM=2836MaximumBHP=5.00 SC-System Curve RP-RatedPoint Packaged Rooftop Builder 1.57 Page 35 of 36 Unit Feature Sheet for RTU-6 Project: —Untitled271 02/22/2021 Prepared By: 02:22PM Carrier ath rM r -4 8 F C PACKAGEDROOFTOPGASHEA71NGIELECTRICCOOIJNG UNITS- 14 SEER 3,4,5TONS,15IEER6Ton STANDARDFEATURESINCLUDE: 0 Puron(R-410A)HFCretrigerant ' 1 0 Meet sarexceedsASHRAE90.1 energyeffiderxylevels f 0 Scrdlcorrpressorswfihintemallinebreakandoverbadprotection • y • Single-stagecoofngcapaaly04-06models,TwoStageon07models r• � 0 SEER'sto14.0,IEER'sto15.0 fiq Ay, 0 AafioYefrgerantmeteringsystemon0406rnodels,TXVon07 r , fly -'7. szemodels r ,�a, Waif rw 0 Exdusive pannaccordancevilh '",.,, s /' ,t . ' ASHRAEStandard62,slopingdesign,sideorcenterdrain " .00 0 Standardcodingoperationupto115°F(46°C)anddownto40°F(4°C) down to 25°F(-4°C)withwinterstartkit. 0 Prepaintedexteriorpanelsandprimer edinteriorpanebtestedto 500hourssattsprayprotedion 0 Fullyinsulatedcabinet 0 NEWDirectDrive-EcoBlueTechnologyIndoaiansystemuses IIlx S H R A E VaneArdalfandesgnandeledron caltyccmmutatedn RRur �y 0 NewUnitConbdBoardwithintutvequickfanspeedalustment �ron 0 ExdusiveIGCsdid-statecontrdforon-boarddiagnosticswilhLED COMPtIANT errorcodedesignationburnercontrolbgic 0 Induceddraftgasheatcombustiondesign 0 Redundantgasvaveswithuptotwostagesofheatng 0 Lowpressrirearxihighpressureswitchproteded. MAIJTENANCEFEATURES: 0 Aocesspanelswitheasygrphancies INEATH31VIAKEFiSERES 0 InnovativeeasystarUng,no-shpscrewsonunitarrPsspands 0 Two-inchdisposableretumairfiltersandTool-Iessfilteramoscdoor 0 NewunitconllYdboardtofadlitatesimplesafetydreuittroubleshooting cooFgritslhalarepreweedatchanyckivithPuon andsimplifiedoonbdboxarrangemEgrit (R-410)1efi4latThe isarefactorytestedinbdh Ik t ysi Kiwiur .3-53nmodelsusesirje INSTALLATIONFEATURES: slageami-gwzriyoriroL6brimcdakEesthostage 0 Thru-the tompowerentrycapatiity 000ingr adfyccntrpf 0 Singlepdntgasandelectiicconnections 0 FullperimeterhaserailwithbuR-inriggingadaptersandforkslots 0 Fieldconvertiblefromverticaltohorizontalairtiow STAPDARDWARRANTY: 0 10-yearheatexchanger-15-yearstainlesssteelopUon p ` 0 3-teSystemVu 0 1-yearparts 0 Manyoptionalupgradesalsoavailatie OP11ONSINCLUDE BUTARE NOTLIMITEDTO: �t • Inte#igentSystemVucon rrxmicatingcontrds C US • RTUOpenMulti-ProtocolDDCContrds • SupplyandRetumAirSmokeDetectors,highstaticmators • Louveredcondensercalguards • Disconnectswitchandconvenienceoutietoptiors • StainlessSteelheatexdiarxgercption • Corrosionresistantcoilcoating. • MERV-SRetumAirFters • PatentedHumidi-MVer `adaptivedehumidificationsystem. • Hingedaccesspanels • Integratedeconomersystem.Lowand UltraLowLeakversiors • PhaseMonitorProtection • CmdensaaeOverflawProtecton ForaoompletelistofoptionsandaaessoriesrefetotheProductData Catalogforthisunit. Packaged Rooftop Builder 1.57 Page 36 of 36 Physical data 48TJ004-007OFFICE COPY %�u, ,ie; , Existing RTU-01,04 UNIT SIZE co � I 004E/F 005D/E/F 006D/E/F 007D/E/F NOMINAL CAPACITY(tons) OPERATING WEIGHT(lb) Unit 1 460 470 490 565 AI/AI +AN �7� Al/Cu* J Gg:9 465 476 497 576 Cu/Cu* G� 468 482 505 587 Economizer G� ...NOV Durablade eta- ir�G 34 34 34 34 Parablade 42 42 42 42 Roof Curbt 115 115 115 115 COMPRESSOR Hermetic Quantity 1 1 1 1 No. Cylinders(per Circuit) 2 2 2 2 Oil (oz) 50 50 50 54 REFRIGERANT TYPE R-22 Operating Charge(lb-oz) Circuit 1 3-6 4-11 5-13 7-10 Circuit 2 — — — — CONDENSER COIL Enhanced Copper Tubes,Aluminum Lanced Fins Rows...Fins/in. 1...17 1...17 1...17 2...17 Total Face Area(sq ft) 7.36 11.39 13.19 10.42 CONDENSER FAN Propeller Type Nominal Cfm 3500 4000 4000 4000 Quantity...Diameter(in.) 1...22.0 1...22.0 1...22.0 1...22.0 Motor Hp...Rpm 1/4...1100 1/4...1100 1/4...1100 1/4...1100 Watts Input(Total) 325 325 325 325 EVAPORATOR COIL Enhanced Copper Tubes,Aluminum Double-Wavy Fins Expansion Device AcutrolTM Feed Device Rows...Fins/in. 2...15 2...15 3...15 4...15 Total Face Area(sq ft) 4.17 5.5 5.5 5.5 EVAPORATOR FAN Centrifugal Type Quantity...Size(in.) Std 1...10 x 10 1...10 x 10 1...11 x 10 1...10 x 10 Alt 1...10x10 1...10x10 1...10x10 — Type Drive Std Direct Direct Direct Belt Alt Belt Belt Belt — Nominal Cfm 1200 1600 2000 2400 Motor Hp Std — — — — Alt — — — — Maximum Continuous Bhp Std .34 .75 1.20 2.40 Alt 1.00 1.00 1.80 — Motor Frame Size Std 48 48 48 56 Alt 48 48 48 — Nominal Rpm High/Low Std 860/800 1075/970 1075/970 — Alt — — — — Fan Rpm Range Std — — — 1070-1460 Alt 760-1000 835-1185 900-1300 — Motor Bearing Type Ball Ball Ball Ball Maximum Allowable Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Min/Max(in.) Std — — — 2.8/3.8 Alt 1.9/2.9 1.9/2.9 2.4/3.4 — Nominal Motor Shaft Diameter(in.) Std 1/2 1/2 1/2 5/e Alt 1/2 1/2 1/2 — Fan Pulley Pitch Diameter(in.) Std — — — 4.5 Alt 4.5 4.0 4.5 — Nominal Fan Shaft Diameter(in.) — — — — Belt, Quantity...Type...Length (in.) Std — — — 1...A...40 Alt 1...A...34 1...A...34 1...A...39 — Pulley Center Line Distance(in.) Std — — — 14.7-15.5 Alt 10.0-12.4 10.0-12.4 14.7-15.5 — Speed Change per Full Turn of Std — — — 80 Movable Pulley Flange(rpm) Alt 48 70 80 — Movable Pulley Maximum Full Turns Std — — — 5 From Closed Position Alt 5 5 5 — Factory Setting Std — — — 3 Alt 3 3 3 — Factory Speed Setting (rpm) Std — — — 1225 Alt 856 975 1060 — Fan Shaft Diameter at Pulley(in.) 1/2 1/2 1/2 1/2 (See legend and notes on page 8.) 7 Physical data 48TF004-007 reil,.,.��; Existing RTU-05 �- —'00 UNIT SIZE 48TF E/F/M/N004 D/E/F/L/M/N005 D/E/F/L/M/N006 D/E/F007 NOMINAL CAPACITY(tons) 3 4 5 6 OPERATING WEIGHT(lb) Unit Al/AI` 460 470 490 565 Al/Cu* 465 476 497 576 Cu/Cu* 468 482 505 587 Economizer Durablade 34 34 34 34 EconoMi$er 47 47 47 47 Roof Curbt 115 115 115 115 COMPRESSOR Reciprocating Scroll Quantity 1 1 1 1 No.Cylinders(per Circuit) 2 2 2 2 Oil(oz) 50 50 1 50 54 REFRIGERANT TYPE R-22 Expansion Device AcutrolTM Metering Device Operating Charge(lb-oz) Circuit 1 4-4 I 6-6 I 6-14 I 9_0 Circuit 2 — — CONDENSER COIL Enhanced Copper Tubes,Aluminum Lanced Fins Rows...Fins/in. 1...17 2...17 2...17 2...17 Total Face Area(sq ft) 8.36 I 8.36 I 10.42 10.42 CONDENSER FAN Propeller Type Nominal Cfm 3500 4000 4000 4000 Quantity...Diameter(in.) 1...22.0 1...22.0 1...22.0 1...22.0 Motor Hp...Rpm i/4...1100 1/4...1100 1/4...1100 1/4...1100 Watts Input(Total) 325 325 325 325 EVAPORATOR COIL Enhanced Copper Tubes,Aluminum Double-Wavy Fins Rows...Fins/in. 2...15 2...15 ...15 ...15 Total Face Area(sq ft) 4.17 3 4 5.5 5.5 5.5 EVAPORATOR FAN Centrifugal Type Quantity...Size(in.) Std 1...10 x 10 1...10 x 10 1...11 x 10 1...10 x 10 Alt 1...10x10 1...10x10 1...10x10 — High-Static 1...10 x 10 1...10 x 10 1...11 x 10 1...10 x 10 Type Drive Std Direct Direct Direct Belt Alt Belt Belt Belt — High-Static Belt Belt Belt Belt Nominal Cfm 1200 1600 2000 2400 Maximum Continuous Bhp Std .34 .75 1.20 2.40 Alt 1.00 1.00 1.30/2.40** — High-Static 2.40 2.40 2.90 2.90 Motor Frame Size Std 48 48 48 56 Alt 48 48 56 — High-Static 56 56 56 56 Nominal Rpm High/Low Std 860/800 1075/970 1075/970 — Alt 1620 1620 1725 — High-Static 1725 1725 1725 1725 Fan Rpm Range Std — — — 1070-1460 Alt 760-1000 835-1185 900-1300 — High-Static 1075-1455 1075-1455 1300-1685 1300-1685 Motor Bearing Type Ball Ball Ball Ball Maximum Allowable Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Min/Max(in.) Std — — — 2.8/3.8 Alt 1.9/2.9 1.9/2.9 2.4/3.4 — High-Static 2.8/3.8 2.8/3.8 3.4/4.4 3.4/4.4 Nominal Motor Shaft Diameter(in.) Std V2 '/2 V2 5/8 Alt 1/2 1/2 5/13 — High-Static 5/8 5/8 5/8 5/8 Fan Pulley Pitch Diameter(in.) Std — — — 4.5 Alt 4.5 4.0 4.5 — High-Static 4.5 4.5 4.5 4.5 Belt,Quantity...Type...Length(in.) Std — — — 1...A...40 Alt 1...A...34 1...A...34 1...A...39 — High-Static 1...A...39 1...A...39 1...A...40 1...A...40 Pulley Center Line Distance(in.) Std — — — 14.7-15.5 Alt 10.0-12.4 10.0-12.4 14.7-15.5 — High-Static 10.0-12.4 10.0-12.4 14.7-15.5 14.7-15.5 Speed Change per Full Turn of Std — — — 80 Movable Pulley Flange(rpm) Alt 48 70 80 — High-Static 65 65 60 60 Movable Pulley Maximum Full Turns Std — — — 5 From Closed Position Alt 5 5 5 — High-Static 6 6 5 5 Factory Setting Std — — — 3 Alt 3 3 3 — High-Static 31/2 31/2 3V2 3'/2 Factory Speed Setting(rpm) Std — — — 1225 Alt 856 975 1060 — High-Static 1233 1233 1396 1396 Fan Shaft Diameter at Pulley(in.) 5/8 5/8 5/8 5/8 LEGEND 1-1-Rollout switch lockout is manually reset by interrupting power to unit or resetting Al — Aluminum thermostat. Bhp — Brake Horsepower • II Single-phase units have a single-stage gas valve.The heating input values are Cu — Copper as follows: 48TFF004,115,000 Btuh *Evaporator coil fin material/condenser coil fin material.Contact your local repre- 48TFF005,150,000 Btuh sentative for details about coated fins. 48TFF006,150,000 Btuh 1-Weight of 14-in.roof curb. NOTES: **Single phase/three-phase. 1. The 48TF004-014 units have a loss-of-charge switch located in the liquid line. 2. High-static motor not available on single-phase units. 7 y Physical data — 48TM004-007ahlgilifth Existing RTU-06 UNIT SIZE 48TM E/F/M/N004 D/E/F/L/M/N005 D/E/F/L/M/N006 D/E/F007 NOMINAL CAPACITY(tons) 3 4 5 6 OPERATING WEIGHT(lb) Unit Al/AI* 460 470 490 615 Al/Cu* 465 476 497 626 Cu/Cu* 468 482 505 637 EconoMi$erIV 50 50 50 50 EconoMi$er2 46 46 46 46 Roof Curbt 115 115 115 115 COMPRESSOR Reciprocating Scroll Quantity 1 1 1 1 No.Cylinders(per Circuit) 2 2 2 2 Oil(oz) 50 50 50 60 REFRIGERANT TYPE R-22 Expansion Device AcutrolTM Metering Device Operating Charge(lb-oz) Circuit 1 4-5 6-6 7-14 11-0 Circuit 2 — — — CONDENSER FAN Propeller Type Nominal Cfm 3500 4000 4000 4100 Quantity...Diameter(in.) 1...22.0 1...22.0 1...22.0 1...22.0 Motor Hp...Rpm '/4...1100 1/4...1100 1/4...1100 1/4...1100 F. Watts Input(Total) 325 325 325 320 00 CONDENSER COIL Enhanced Copper Tubes,Aluminum Lanced Fins d' Rows...Fins/in. 1...17 2...17 2...17 ...17 Total Face Area(sq ft) 8.36 2 8.36 10.42 16.5 EVAPORATOR FAN Centrifugal Type Quantity...Size(in.) Std 1...10 x 10 1...10 x 10 1...11 x 10 1...10 x 10 Alt 1...10x10 1...10x10 1...10x10 — High-Static 1...10 x 10 1...10 x 10 1...10 x 10 1...10 x 10 Type Drive Std Direct Direct Direct Belt Alt Belt Belt Belt — High-Static Belt Belt Belt Belt Nominal Cfm 1200 1600 2000 2100 Maximum Continuous Bhp Std .34 .75 1.20 2.40 Alt 1.20 1.20 1.30/2.40** — High-Static 2.40 2.40 2.90 2.90 Motor Frame Size Std 48 48 48 56 Alt 48 48 56 — High-Static 56 56 56 56 Nominal Rpm High/Low Std 860/800 1075/970 1075/1040 — Alt 1620 1620 1725 — High-Static 1725 1725 1725 1725 Fan Rpm Range Std — — — 1070-1460 Alt 685-1045 770-1175 900-1300 — High-Static 1075-1455 1075-1455 1300-1685 1300-1685 Motor Bearing Type Ball Ball Ball Ball , Maximum Allowable Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Min/Max(in.) Std — — — 2.8/3.8 Alt 1.9/2.9 1.9/2.9 2.8/3.8 — High-Static 2.8/3.8 2.8/3.8 3.4/4.4 3.4/4.4 Nominal Motor Shaft Diameter(in.) Std 1/2 1/2 I/2 5/8 Alt V2 V2 5/8 — High-Static 5/8 5/8 7/8 7/8 Fan Pulley Pitch Diameter(in.) Std — — — 4.5 Alt 4.5 4.0 5.5 — High-Static 4.5 4.5 4.5 4.5 Belt,Quantity...Type...Length(in.) Std — — — 1...A...39 Alt 1...A...36 1...A...36 1...A...40 — High-Static 1...A...39 1...A...39 1...A...40 1...A...40 Pulley Center Line Distance(in.) Std — — — 14.7-15.5 Alt 10.0-12.4 10.0-12.4 14.7-15.5 — High-Static 10.0-12.4 10.0-12.4 14.7-15.5 14.7-15.5 Speed Change per Full Turn of Std — — — 80 Movable Pulley Flange(rpm) Alt 48 70 80 — High-Static 65 65 60 60 Movable Pulley Maximum Full Turns Std — — — 5 From Closed Position Alt 5 5 5 — High-Static 6 6 5 5 Factory Setting Std — — — 3 Alt 3 3 3 — High-Static 3'/2 31/2 31/2 31/2 Factory Speed Setting(rpm) Std — — — 1226 Alt 829 932 1100 — High-Static 1233 1233 1416 1416 Fan Shaft Diameter at Pulley(in.) 5/8 5/8 5/8 5/8 EVAPORATOR COIL Enhanced Copper Tubes,Aluminum Double-Wavy Fins Rows...Fins/in. 2...15 ...15 3...15 4...15 Total Face Area(sq ft) 4.17 I 25.5 I 5.5 I 5.5 LEGEND ***Three-phase standard high heat models have heating input values as shown. Al — Aluminum Single-phase standard high heat models have one-stage heating with heating Bhp — Brake Horsepower input values as follows: Cu — Copper 48TMF004—115,000 Btuh 48TMF005,006—150,000 Btuh *Evaporator coil fin material/condenser coil fin material.Contact your local repre- tttCalifornia SCAQMD compliant Low NO. models have combustion products sentative for details about coated fins. that are controlled to 40 nanograms per joule or less. tWeight of 14-in.roof curb. **Single phase/three-phase. NOTES: ft-Rollout switch lockout is manually reset by interrupting power to unit or resetting 1• High-static motor not available on single-phase units. thermostat. 2. An LP kit is available as an accessory.Kit may be used at elevations as high as 2000 ft.LP kit is not used with Low NOx units. 28