Specifications OFFICE COPY WALL SIGN DESIGN 1V ''fi ' Scope of work is for the design of the connection of the wall sign to the existing structure only. ,2 oc? 13 cl"202 x R -- See last two pages for structural notes. �/�/�� �,,�, �/.'�p' ASCE 7-16-Components and Cladding / /9' 4447 74 9000 ' �/•\ JAN 13 7.022 Wind Speed,V= 98 mph Y� 7' Risk Category= II CITY Exposure Category= B CIT l C'F11ui4 f.; Sign Height= 20.00 ft(max) L J EVNG 1INV SON Topo.Factor,Kzt= 1.00 l 6lJ•P� Direct.Factor,Kd= 0.85 Corner Zone:Yes ResWall Extegrnal Pnal Pressursre andC Coefficients: ici ,Gcc�Dr1 fro/Cis Wall External Pressure Coefficients,GCp: r�( GCp Zone 4 Pos.= 0.90 O GCp Zone 5 Pos.= 0.90 � G I N F R / GCp Zone 4 Neg._ -0.99 GCp Zone 5 Neg.= -1.26 725 PE a= 7.00 zg= 1200 Kh= 0.70 qh= 8.8 psf =0.00256'0.7"1"0.85*98^2'(0.6,allowable) ON O Case 1,F(-)_ -11.1 psf =(-1.26)*8.8psf y n. Case 2,F(+)= 7.9 psf =(0.9)*8.8psf ' RY 0 8 ' �� Sign Geometry: Height= 5.83 ft(total) F ✓OSEPH ' ' Width= 11.33 ft(max) %solid area= 100% EXPIRES:12-31-2022 Area= 66.1 ft2 =5.83"11.33"100% Sign Thickness= 4.00 in(channel letters or cabinet) Sign Dead Load= 4.00 pet(max) Appx.Weight= 264 lb =4psf 66.1 Vertical offset= 0.00 in(positive#denotes centroid of sign above centroid of connection) No offset,sign flush to surface. fastener couple= 60.00 in(vertical) Total#of fasteners= 14 (minimum) 50% of fasteners resisting tension due to eccentricities(along top of connection) V,fastener= 19 lb =264/(14 fasteners) M,o„e,n,case 1= -22539 in-lb =-11.1*66.1"(60"/2)-264"(4"/2) • R,upper,case 1= 54 lb(tension)=22539/60"/(14 fasteners'50%) M,op,case 1= -21483 in-lb =-11.1*66.1"(60"/2)+264*(4"/2) R,lower,case 1= 51 lb(tension)=(21483/60")/(14 fasteners'50%) Mbo„o,„,case 2= 15138 in-lb =7.9"66.1"(60"/2)-264*(4"/2) . R,upper,case 2= 36 lb(tension)=15138/60"/(14 fasteners*50%) M,oP,case 2= 16194 in-lb =7.9`66.1*(60"/2)+26414"/2) R,lower,case 2= 0 lb no tension occurs along lower support 1/4"dia.wood screws from sign cabinet through finish thickness= in(non-structural) existing plywood sheathing.Typical at(14) o.d.of pipe spacer= in approximate locations shown. add'I tension= 0 lb T,fastener= 54 lb V,fastener= 19 lb 11'-4.. Wall Const.:Plywood/Wood -- --__-� _ Fastener Type:Screw Fastener Size: 0.250 in Tc= 70 Ib>54 OK 77% • • • • • Vc= 118 Ib>19 OK 16% 0.93<1.00 OK Use 0.25"Screw to Plywood/Wood :._ 1(1DI1I1iI " "T ,.._ 4**11 ,.. ,.., „.., i,.. _. .., , ...i „! 1 ,_, 1 ;:.,, , ACADEMY® 1 • 1 : , EDUCATIONAL CHILD CARE ' _• • fi Project Name Kiddie Academy Wall Sign Cabinet Project# 220008 MILLER laCONSULTING Location 16146 SW Upper Boones Ferry Road, Tigard, OR ENGINEERS Client Ramsay Signs • 9600 SW Oak St#400 1 503.246.1250 ��'f1�t � Portland,OR 97223 miller-se.com By NWS Ck'd l"Jr Date 01/07/2022 Page 1 of 3 GENERAL THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. SHOULD ANY QUESTION ARISE REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE CONTRACTOR SHALL REQUEST INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNING THE PROJECT. THE ABSENCE OF SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED AND FAMILIARIZED HIMSELF WITH ALL ASPECTS OF THE PROJECT AND HAS COMPLETE COMPREHENSION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE SPECIFICALLY NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION OR CONSTRUCTION LOADS. ONLY THE CONTRACTOR SHALL PROVIDE ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO PROTECT THE STRUCTURE, WORKMEN AND OTHER PERSONS AND PROPERTY DURING CONSTRUCTION. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY PRECAUTIONARY MEASURES SHALL BE USED AND INSPECT SAME IN THE FIELD. ANY MATERIAL NOT AS SPECIFIED OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. THESE PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS DISCLAIMS ALL LIABILITY IF THESE PLANS AND SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION SPECIFIED HEREIN. OBSERVATION VISITS TO THE JOB SITE AND SPECIAL INSPECTIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY UNLESS THE CONTRACT DOCUMENTS SPECIFY OTHERWISE. NON STRUCTURAL PORTIONS OF PROJECT, INCLUDING BUT NOT LIMITED TO PLUMBING, FIRE PROTECTION, LAND USE, SITE PLANNING, EROSION CONTROL, ELECTRICAL, MECHANICAL, FLASHING AND WATER-PROOFING ARE BEYOND THE SCOPE OF THESE DRAWINGS AND ARE PROVIDED BY OTHERS. EXISTING STRUCTURAL ELEMENTS ARE DESIGNED BY OTHERS. ANALYSIS FOR MOVEMENT DUE TO VORTEX SHEDDING OF WIND FORCES IS NOT INCLUDED IN THE SCOPE OF WORK. IF MOVEMENT CAUSED BY VORTEX SHEDDING IS A CONCERN, WIND TUNNEL TESTING OR OTHER ANALYTICAL MODELS SHALL BE UTILIZED TO EVALUATE THE STRUCTURE. CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO FABRICATION OR INSTALLATION. ENGINEER OF RECORD FOR THE PROJECT IS TO BE NOTIFIED IF CONDITIONS DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. BUILDING CODE ALL PHASES OF THE WORK SHALL CONFORM TO THE 2019 OREGON STRUCTURAL SPECIALTY CODE, BASED ON THE 2018 INTERNATIONAL BUILDING CODE, INCLUDING ALL REFERENCE STANDARDS, UNLESS NOTED OTHERWISE. ���p PROFFs��� aGtNFF 4/ 725 PE ) l ON o y 0a . tiQ�Qe ✓OSEPH�P� EXPIRES:12-31-2022 . Project Name Kiddie Academy Wall Sign Cabinet Project# 220008 MILLER CONSULTING Location 16146 SW Upper Boones Ferry Road, Tigard, OR ENGINEERS Client Ramsay Signs 9600 SW Oak St#400' 503.246.1250 Portland,OR 97223 miller-se.com By NWS Ck'd P Date 01/07/2022 Page 2 of 3 DESIGN LOADS THE FOLLOWING ARE THE DESIGN REQUIREMENTS: STRUCTURAL DESIGN CRITERIA RISK CATEGORY II WIND DESIGN DATA BASIC WIND SPEED(3 SEC GUST) 98 MPH EXPOSURE B ALUMINUM ALL STRUCTURAL ALUMINUM SHAPES AND PLATES TO BE 6061-T6.ALL WELDS TO USE[4043][5356]ALUMINUM FILLER ALLOY.A PROTECTIVE BARRIER SHALL BE PROVIDED BETWEEN ALL STEEL AND ALUMINUM TO PREVENT CORROSION.ALL WELDING TO CONFORM TO AMERICAN WELDING SOCIETY(AWS)D1.2.WELD LENGTHS SHOWN ARE EFFECTIVE AS SPECIFIED PER THE ALUMINUM DESIGN MANUAL.WELDING SHALL BE BY AWS CERTIFIED WELDERS FOR WELD TYPES SPECIFIED.WHERE WELD LENGTHS ARE NOT SHOWN, THE WELD SHALL BE FULL LENGTH OF MEMBERS BEING JOINED.ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS UNLESS NOTED OTHERWISE ON STRUCTURAL DRAWINGS.ALL WELDS TO RECEIVE THE SAME FINISH COAT AS THE MEMBER BEING WELDED.ALL FASTENERS IN CONTACT WITH ALUMINUM TO BE HOT DIPPED GALVANIZED WITH MATCHING NUTS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION. WOOD FRAMING ALL STRUCTURAL WOOD COLUMNS AND BEAMS TO BE DOUGLAS FIR/LARCH (DF/L), #1 UNLESS NOTED OTHERWISE. ALL JOISTS, PURLINS, AND GIRTS TO BE DF/L#2 AND BETTER UNLESS NOTED OTHERWISE. ALL BLOCKING AND NON- STRUCTURAL FRAMING TO BE CONSTRUCTION GRADE AND BETTER. ALL WOOD PLATES IN CONTACT WITH CONCRETE OR MASONRY SHALL BE HEM-FIR#2 PRESSURE TREATED UNLESS NOTED OTHERWISE. ALL PREFABRICATED METAL TIMBER CONNECTORS AND HANGERS SHALL BE FULLY BOLTED AND/OR NAILED AS INDICATED BY MANUFACTURER, UNLESS NOTED OTHERWISE.ALL CONNECTORS, HANGERS AND FASTENERS SHALL BE CORROSION PROTECTED PER MANUFACTURER'S RECOMMENDATIONS. SIMPSON PREFABRICATED METAL TIMBER CONNECTORS NOTED. OTHER TYPES OF METAL CONNECTORS REQUIRE PRIOR REVIEW. UNLESS NOTED OTHERWISE, ALL BOLTS TO BE ASTM A307 AND ALL ANCHOR RODS TO BE ASTM F1554 GRADE 36, WITH MATCHING NUTS. ALL FASTENERS IN CONTACT WITH ALUMINUM TO BE HOT DIPPED GALVANIZED WITH MATCHING NUTS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION PER RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC) SPECIFICATION FOR STRUCTURAL JOINTS, SECTION 8.1. \c'ED PROFFs \� aG 1 rvF�'�/O 4` 725 PE - ON o ale 'Tv 0 s , ��Q� ✓OSEPH \\°\ EXPIRES: 12-31-2022 /IFSProject Name Kiddie Academy Wall SignCabinet Project# 220008 MILLER_ CONSULTING Location 16146 SW Upper Boones Ferry Road, Tigard, OR ENGINEERS Client Ramsay Signs 9600 SW Oak St#400 503.246.1250 p�'A Portland,OR 97223 miller-se.com By NWS Ck'd '-' Date 01/07/2022 Page 3 of 3