Report /U 61 Cj2c L36a24 f .cf iqL�G 2D,z2- oOv.:K.
Titus Submittal DTQP-ECM-1.0 04-26-2017
DTQP with TITANTM Programmed ECM Motor RECEIVED
Fan Powered Terminal, Parallel Flow with ECM Motor JAN 11202x
Direct Digital Control, Pressure Independent
CITY OF TIGA�+R/D�y
33/8 N 20 - H BUILJING DIVISION
12
0 0 o m 0 0 61/4 m"{ f 0
0
Pil- ' it nor
A11 E
i •.�u�JL w
•
Primary Air Inlet
with Multipoint c 0 c
Center Averaging t ' _ VJ
� Sensor 1
+ . •
I4 F
:_ Induced Air 2- • y,1 • G
1
1 Inlet
11/4-- L - ..—J_--. -
Left hand unit,top view shown.All dimensions are in inches.
Right hand units are built as a mirror image. Inlets,discharge,and control enclosure are opposite of the drawing above. 0
Unit Size Inlet Size A B C D E F G H J K L IN N Filter Size
6 6 7'/8 2'/e
3,4 10 7 8 a/18 16 3/4 9 778 14 1/2 14 3 1/2 17 1/a 11 2 1/8 40 7/8 36 1/8 4 7�/8 19 x 17
11 /8 4 /8
12 8 13 7/8 6 7/8
14 10
12 8 11 7/8 4 7/8
5,6 14 10 10 1/18 24 1/2 13 7/8 17 1/2 16 1/2 91/2 201/8 141/2 3 1/8 46 7/8 48 1/8 6 7/8 27 x 20
16 11 157/8 67/8
ECM Motor Amperage Ratings
Accessories (Optional)
Unit Motor 120V/1/60 208V/1/60 277V/1/60 Check El if provided.
Size hp FLA FLA FLA
❑ Induced Air Filter,1"thick,disposable construction type
3,4 1/2 7.7 5.0 4.1
5,6 1 12.8 10.5 6.9 ❑ Fan disconnect switch(not available on units with optional electric coils)
❑ Fibre Free Liner ❑ 1"Fiberglass Liner
FLA=Full Load Amperage, rated per the motor nameplate 0 SteriLoc Liner 0 1"EcoShield Liner
All fan motors are single phase, same voltage as electric coil (when El 'A"EcoShield Liner El 1"EcoShield Liner(Foil Face)
supplied), with exception that 277 V motors are used with 480V, 3 ❑ '/2"EcoShield Liner(Foil Face) ❑ 1"Fibre Free Liner
phase coils(4 wire wye). ❑ '/A"Fibre Free Liner ❑ Hanger Brackets
0 UltraLoc Liner ❑ Cam Latch for Access Door
❑ Fan unit fusing
El
1
DTQP-ECM-2.0 04-26-2017
Accessories (Optional)
❑ Hot Water Coil Section
• • 1/2"copper tubes a 0 0 0 0 0 0
• Aluminum ripple fins,10 per inch ••• Connections:Male solder,5/8"for • r • le•
I
1 both 1-row and 2-row.Right hand • 171 IF vN
connections only on left hand units. - �� �� �f ii
"� �JL�
Left hand only on right hand units. . .
• Galvanized steel casing
• Flanged duct connection.
• Coil is installed at induced air inlet. .
t
• - . 1
CI Row r -r-71I.•�_7
❑ 2 Row o
R I .
1. .
I
L-----L-�I� �I__J
I
1"Typi �� J k 1� •
•
S - --M 9 -
Unit Size M(1 row) M(2 row) R S
3,4 1 1 /4 17 15
5,6 1 1 1/4 25 171/2
R and S are inside dimensions.
Accessories (Optional)
0 Hot Water Coil Section (Discharge Side)
l
• 1/2"copper tubes
• Aluminum ripple fins, 10 per inch ° °
• Connections:Male solder,5/8"for • ir• •. { •+
both 1-row and 2-row.Right hand , ihr
and left-hand connections available �1 II ILI` • .
regardless of handing of controls. • JL j. ram" p
• Galvanized steel casing
• Flanged duct connection.
• Coil is installed at induced air inlet.
t •
❑ 1 Row r r--ni.• -7 I
I
❑ 2Row i
1
1. R
L____L-_-I"L_J S
I
1"TYp•J U 1J
-
9 S --M
Unit Size M(1 row) M(2 row) R S
3,4 1 11/4 17 15
5,6 1 1 '/4 25 171/2
• R and S are inside dimensions.
DTQP-ECM-3.0 04-26-2017
❑ Electric Coil Section ❑ Optional SCR Controlled Electric Heater ❑ Optional Lynergy Controlled Electric Heater
Standard Features
• Single side access to low voltage, 31 1
high voltage,and electric heater
controls.
t • Automatic reset thermal cutouts,one o 0 0 o a o
1 per element
• Single point electrical connection for • II- ��f ` •
[ entire unit • ir Heater Rack
• Positive pressure flow switch 4ii iE ii ccess cover
• Flanged duct connection •.JLJL4../" . . r
• Coil is installed at discharge of unit.
• Transformer
Options t •
I �
1"Typ.
II Fuse Block r1_ : 1 _ 1
iI
❑ Disconnect switch,door
i nterlock type • -
❑ Manual reset cutout
❑ Dust tight construction L J_' '._J
❑ Mercury contactors t • • L4,1,- • • t �. I
Supply Voltage si T
❑ 208V, 1 ph,60Hz
❑ 240V, 1 ph,60Hz
❑ 277V, 1 ph,60Hz Unit Size U R S T
❑ 208V,3 ph,60Hz
❑ 480V,3 ph,60Hz(4 wire wye only) 3,4 3'/2 14 11 2'/8
5,6 9 1/2 16 1/2 14 1/2 3 1/8
R and S are inside dimensions.
General Description
• Heavy steel casing,with leak • Efficiencies of up to 70%across • Pressure independent primary
resistant construction. the entire operating range. flow control.
• Dual density insulation, coated to • Provides a large turndown ratio • Single point electrical
prevent air erosion, meet • Constant volume regardless of connections.
requirements of NFPA 90A and changes in downstream static • Rectangular discharge opening is
UL 181. pressure allows for factory setting designed for flanged duct
• Ultra high efficiency, brushless of cfm. connections.
DC ECM motor with a unique • Bottom access panels can be
microprocessor based motor removed for service.
controller. • Multipoint, center averaging
• Manual PWM controller allows velocity sensor.
simple screwdriver adjustment of • Primary air flow balancing
fan speed. connections.
• Remote PWM controller allows
for a 0-10 V signal from the DDC
controller to adjust the fan speed.
This submittal is meant to demonstrate general dimensions of this product.The drawings are not meant to detail every aspect of the product.Drawings are not to scale.Titus
reserves the right to make changes without written notice.
All nghta reserved.No pert of this work may he reproduced or transmitted In any form of by any means.electronic or mechanical,including photocopying and recording,or by any Information storage retrieval system wahaut permission In wMing from Par Detnbution Technologies,Inc.