Loading...
Report (3) t f(o y P/tG!FcC f7 NI &C2O22--o a O 2c,f Unit Report For 48TC-7.5T-D-3PH RE Project: Stock Units 2019 03/04/2019 Prepared By: 10:30AM Go i ,$aARD BURLDNG Unit Parameters Dimensions (ft.in.)&Weight(Ib.)*** Unit Model. 48TCDDO8A2A5-0A0G0 Unit Length• 7'4.125" Unit Size. 08(7.5 Tons) Unit Width. 4' 11.5" Volts-Phase-Hertz. 208-3-60 Unit Height. 3'5.25" Heating Type• Gas ••* Total Operating Weight. 870 lb Duct Cfg• Vertical Supply/Vertical Return Low Heat `'* Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size- 1/2 Condensate Drain Line Size• 3/4 Return Air Filter Type• Throwaway Return Air Filter Quantity 4 Return Air Filter Size• 16 x 20 x 2 Unit Configuration Medium Static Option (Belt Drive) Al/Cu -Al/Cu Base Electromechanical Controls Standard Packaging 2-Speed indoor fan motor controlled by VFD Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) • 10-Year heat exchanger-Aluminized(std.) 15-Year heat exchanger-Stainless Steel(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDDO8A2A5-0A0G0 Rooftop Unit 1 Base Unit Medium Static Option (Belt Drive) Electromechanical control, No intake or exhaust option. 2 Speed Fan Controller (VFD) Packaged Rooftop Builder 1.49n Page 1 of 7 Certified Drawing for 48TC-7.5T-D-3PH - Project: Stock Units 2019 03/04/2019 Prepared By: 10:30AM NOTES: UNITED P.O.BOY MBDB THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION UNIT OUTDOOR 6 H TECHNOLOGIES SYRACUSE.NY AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE SUBMISSION OF THESE DRARIROS OR DOCUMENTS 1. DIMENSIONS ARE IN INCHES. DIMENSIONS COIL TYPE CONTENTS WILL MOT BE DISCLOSED OR USED WITHOUT CARRIER DOES NOT CONSTITUTE PART PENFODRANCf OR IN [ I ARE IN MILLIMETERS. 41 1/4 33 15 1/8 CARRIER uzzl CORPORATION'S WRITTEN CONSENT. ACC fPTAMCC OF COYTRACT. 2. CENTER OF GRAVITY 48TC-A08 RTPF [10481 [658] 14031 48TC-A09 RTPF 49 3/8 37 1/401 7/8 CONNECTION SIZES [12531 [9461 [708) A 1 3/8' [351 DIA FIELD POWER SUPPLY HOLE 3. *DIRECTION OF AIR FLOW 40-3/8 4DEC-Al2 RTPF 49 3/B 37 114 15 7/B [1253] [946] [403] [1026] B 2 1/Z' [61] DIA POWER SUPPLY KNOCKOUT 41 1/4 33 15 7/8 48TC-D08 RTPF C 1 3/4' [51] DIA GAUGE ACCESS PLUG [1048] [6581 [4D3] , , IBTC-D09 RTPF 49 3/8 37 1/4 15 7/8 D 7/8' 1221 DIA FIELD CONTROL WIRING HOLE [1253] [9461 1403] 20-3/4 E 3/1"-14 NPT CONDENSATE DRAIN 49 3/6 37 1// 15 7/B ECONOMIZER H000 F 1/2'-14 NPT GAS CONNECTION 48TC-D12 RIPE (12531 [9/61 [403] • (OPTIONAL) • [527] 3/4'-14 NPT GAS CONNECTION 48TC-008 NCH% 1 1/4 33 23 [14048] [6561 [584.2] G 2' [511 DIA POWER SUPPLY KNOCK-OUT 48TC-D12 NCH% [1253 49 8 [946137 4 [279.41 '' ' I~ _S. THRU-THE-BASE CHART (FIELD INST) RTPF-ROUND TUBE, PLATE FIN )COPPER/ALUM) NCH-NOVATION [ALUM/ALUM/ \\\\\\\\ I THESE HOLES REQUIRED FOR USE WITH ACCY NITS: I([IIIIf��( `111'1 [92518 �3zj/B 1M CRBTMPWROD4A01: GAS THRU CURB CRBTMPWAOOIA01: GAS THRU BASEPAX • w1 ���®� I RETURN AIR RETURN 1V �� _ _ .. AIR THREADED WIRE RED'D HOLE __ \� � L CONDUIT1 SIZE USE SIZES (MAX./ D 11110 _ ��— W 1/2" ACC. 7/8' [22.2] FILTER ACCESS PANEL % 1/2' 24V 7/8' [22.2] (TOOL-LESS) n E ALT. , \ CONDENSATE Y 1 1/4" (002,0041 POWER 1 3/4" [44.4] COIL ��% -\;\1`DAA IN OPENING 28-3/4 CONDENSER /jam'�\'; IN BASEPAX [7311 37-5/8 40-3/8 Z N (DOC 3/4' FPT GAS 1 3/4' [44.4] • W SUPPLY [9551 [10271 1141i:1A m LY,lllill SEE THRU AIR (0021 PROVIDES 3/4' FPT THRU CURB INDOOR COIL 1 - \\\\\\\_-- /i/////// % SUPPLY N ACCESS PANEL \ ��,`=. � Y THE BASE AIR FLANGE 4 FITTING. HOLE SIZE: 2' [50.81 ���� - A' CHART BACK 18 6 ;` 2 14691 Ig12] tq 11 L -�- ____I THRU-THE-BASE CHART (FIOP) [355] 4v 1218] tr.'.v - —�- -{ - - UU N tT[y F 1- ✓!R FOR 'THRU-THE-BASEPAN"FACTORY OPTION,A F FITTINGS FOR ONLY I. Y. 2 ARE PROVIDED. NN • } FOR BELOW LISTED MODELS. A FIELD L 6-1/4 SUPPLIED 1/2" ADAPTER IS REOUIRED --29 SIB [100] LUE 74 [1591 WA BETWEEN BASE PAN FITTING AND GAS VALVE: [7511 HOOD y 14 [831 48HCD,S008 [3561 TOP „25-1/2 [647] H 1-1/4 [321 11-7/8 4-5l8 [302] 11181 1---i LECTRICAL CONTROL BOX DISCONNECT E$TDI I TITER IL A. �+� LOCATION ACCESS PANEL CONDENSER G, I CONDENSATE DRAIN OPTIONAL ® ACCESSOO BLOWER ,I 11010 FACTORY _____ OPTIONAL •� INSTALLED FACTORY 27-TIB 21_3/4 OUTSIDE INSTALLED [1-1) • DISCONNECT \ AIR CONVENIENCE C l.. F HANDLE 13-1/8 [706] 26 OUTLET [334] - SUPPLY AIR [659] •I HANDLE-�� J�s -__-.-Eli _ II 6-5/B - __ "68] 1• ti 6 1/8 __ _• �. 3-3/4 6-5/8 7 [951 59-1/2 2-5/8 8-3/B [1671 [177] 6-1/B /-3/8 [1510] [671 37 12141 TIP 37-7/8 [1551 [113] [9401 [9621 42-3/8 LEFT WIDTTH 88-1/8 .. [10751 BAROMETRIC [22381 SUPPLY * RETURN RELIEF AIR AIR FLOW FRONT RIGHT INERT DATE SUPCRCEDES 48TC 08-12 SINGLE ZONE ELECTRICAL REV 48TM500985 1OF2 03-08-10 11-24-08 COOLING WITH GAS HEAT F Packaged Rooftop Builder 1.49n Page 2 of 7 Certified Drawing for 48TC-7.5T-D-3PH Project: Stock Units 2019 03/04/2019 Prepared By: 10:30AM 40 UNITED P.O.BOY 4800 THIS DOCUMENT IS THE PROPERTY Of CARRIE!CORPORATION SUBMISSION OF THESE DRAWINGS OR DOCUMENTS TECHNOLOGIES SYRACUSE,n AND IS OE LIVERED UPON THE EIPAE3S CORGI TIOX THAT THE DOES NOT CONSTITUTE PART PERFORMANCE OR STD. UNIT CORNER CORNER CORNER CORNER CARRIER 1322t CONTEXTS MIEE MDT BE 014CLOSFO OR USED YITNOUT CARRIER ACCEPTANCE Of CONTRACT. UNIT OUTDOOR WEIGHT RNP WEIGHT IAl WEIGHT IBl WEIGHT ICI WEIGHT IDI C.G. COAPORAiIOX'3 RR[TTEN COXSCMi. COIL TYPE LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z 48TC-A08 RTPF 780 354 118 81 158 72 209 95 236 107 41 1/2 [10541 33 7/8[8601 20 1/2 [521] vox STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. 48TC-A09 RTPF 920 418 212 96 183 83 243 110 282 128 40 7/8[1038] 34 [864] 23 1/8 [587] FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. 48TC-Al2 RTPF 930 422 216 98 196 89 _ 241 112 272 123.5 42 MOM 33 1/8[841] 24 1/4 [616] 48TC-D08 RTPF 835 379 164 74.5 110 77.2 255 115.8 246 111.7 44 7/8 [1140] 35 5/8[9051 19 3/8 [4921 48TC-009 RTPF 930 422 228 103.5 187 85 232 105.3 283 128.5 39 3/4 [10101 32 7/8[8351 18 5/8[473] 48TC-012 RTPF 940 421 231 104.9 189 85.8 234 106.2 286 129.8 39 3/4 11012] 33 [838] 18 1/2 [470] 48TC-008 MCHX 805 365.5 160 72.6 153 69.5 240 109 260 118 43[1092] 36 3/8 [9241 20 3/8 [517.7] 48TC-012 MCHX 895 406.3 185 84 176 79.9 260 118 214 124.4 42 7/8[10891 35 1/2 [9021 22 7/8[581] RTPF -NCH% - ROUND TUBE, IALUM/ALUMI B PLATE N (COPPER/ALUM) CORNER A NOVA CORNER B r .-.... • Wiz, R ..R CORNER D _ CORNER C TOP - X g • pr. O ED Cj00 `='1' .. , ii : : 00 FRONT SHEET DATE. SUPERCEOES 48TC 08-12 SINGLE ZONE ELECTRICAL REP 1 20F2 03-08-10 11-24-08 COOLING WITH GAS HEAT 48TM500985 F Packaged Rooftop Builder 1.49n Page 3 of 7 Certified Drawing for 48TC-7,5T-D-3PH Project: Stock Units 2019 03/04/2019 Prepared By: 10:30AM Service Clearance ,Z \s�/ i 1 C1124i LOCATION DIMENSION CONDITION _ 48-in(1219 mm) •Unit disconnect is mounted on panel 36-in(914 mm) •If dimension-8 is 12-in(305 mm) A 18-in(457 mm) •No disconnect,convenience outlet option •Recommended servicedearance(use electric screwdriver) 12-in(305 mm) •Minimum clearance(use manual ratchet screwdriver) 36-in(914 mm) •Unit has economizer 8 12-in(305 mm) •if dimension-A is 36-in(914 mm) Special •Check for sources of flue products within 10-ft of unit fresh air intake hood _ C 36-in(914 mm) •Side condensate drain is used 18-in(457 mm( •Minimum clearance 48-in(1219 mm) •No flue discharge accessory installed,surface is combustible material 42-in(1067 mm) •Surface behind servicer Is grounded(e.g.,metal,masonry wall,another unit) D 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or!wilding fresh air intakes within 10-ft of this units flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. Packaged Rooftop Builder 1.49n Page 4 of 7 Performance Summary For 48TC-7.5T-D-3PH Project: Stock Units 2019 03/04/2019 Prepared By: 10:30AM Part Number:48TCDDO8A2A5-0A0G0 ARI EER. 11.00 IEER• 12.8 Base Unit Dimensions UnitLength:_.........___.......___._.........__......._._.__._._......._........_...__.......__ 88.1 in Unit Width _ _ _..................-•......--..........-•.... — ----- — 59.5 in Unit Height• _ 41.3 in Operating Weight Base Unit Weight _.._...__._.__._.__ 835 lb Medium Static Option (Belt Drive)• 15 lb 2 Speed Fan Controller (VFD)• _ 20 lb Total Operating Weight _____ 870 lb Unit Unit Voltage-Phase-Hertz. 208-3-60 Air Discharge. Vertical Fan Drive Type• Belt Actual Airflow• _ — 3000 CFM Site Altitude. 39 ft Cooling Performance Condenser Entering Air DB• 90.0 F " Evaporator Entering Air DB• _ 78.0 F Evaporator Entering Air WB• 64.4 F Entering Air Enthalpy. 29.49 BTU/lb • Evaporator Leaving Air DB. 56.2 F Evaporator Leaving Air WB• 54.6 F Evaporator Leaving Air Enthalpy. 22.93 BTU/lb Gross Cooling Capacity. 88.40 MBH Gross Sensible Capacity. _ 70.45 MBH Compressor Power Input _ 5.97 kW Coil Bypass Factor• _ 0.104 Mixed Air Outdoor Air Airflow• 420 CFM Outdoor Air DB. _ 90.0 F Outdoor Air WB. — 67.0 F Outdoor Air Htg.Temp.: 22.0 F Return Air DB• — 76.0 F Return Air WB —__.______._ 64.0 F Return Air Htg.Temp • 70.0 F Heating Performance Heating Airflow:__._______ 3000 CFM Entering Air Temp• _ 63.3 F Leaving Air Temp. 95.1 F Gas Heating Input Capacity. — 125.0 MBH Gas Heating Output Capacity. 103.0 MBH Temperature Rise. — 31.8 F Thermal Efficiency(%). 82.0 Supply Fan External Static Pressure. _ 0.60 in wg Fan RPM. 761 • Fan Power. 1.64 BHP NOTE- Selected IFM RPM Range: 733-949 Electrical Data Packaged Rooftop Builder 1.49n Page 5 of 7 Performance Summary For 48TC-7.5T-D-3PH Project: Stock Units 2019 03/04/2019 Prepared By: 10:30AM Voltage Range. 187-253 ' Compressor#1 RLA:_________.__ 13.6 . Compressor#1 LRA• 83 Compressor#2 RLA• 13.6 Compressor#2 LRA• _ 83 Indoor Fan Motor Type• MED Indoor Fan Motor FLA• 8.4 Combustion Fan Motor FLA(ea)• 0.48 Power Supply MCA• 43 Power Supply MOCP(Fuse or HACR)• 50 Disconnect Size FLA• 45 Disconnect Size LRA• 227 Electrical Convenience Outlet. None Outdoor Fan [Qty/FLA(ea)]. 2/1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 98.2 95.2 85.8 125 Hz 91.4 86.0 84.3 250 Hz 77.9 73.0 80.5 500 Hz 70.7 66.3 78.7 1000 Hz 67.1 63.3 76.4 2000 Hz 65.7 58.5 72.7 4000 Hz 67.1 57.8 68.3 8000 Hz 69.3 57.4 65.1 I • A-Weighted 79.4 74.3 82.0 Advanced Acoustics ti t 0 i O4., 0 i_ ... 3. 0 1/4" Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground- 5.7 ft 4. Height of obstruction• 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction- 0.0 ft . Detailed Acoustics Information • Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall Packaged Rooftop Builder 1.49n Page 6 of 7 Performance Summary For 48TC-7.5T-D-3PH Project: Stock Units 2019 03/04/2019 Prepared By: 10:30AM A 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 89.6 Lw B 59.6 68.2 71.9 75.5 76.4 73.9 69.3 64.0 81.4 LwA C 53.4 51.9 48.1 46.3 44.0 40.3 35.9 32.7 57.2 Lp D 27.2 35.8 39.5 43.1 44.0 41.5 36.9 31.6 49.0 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2.0 0 RP,A 1000 PM 1100 RP 1 0 RPM 1.8 `\\ 800 RPM 1.6 1.4 - 700 RPM 1.2 _ 5 on•,4=+ y 1.0 a_ -.0 AIL 41111111.11 500 RPM 0.6 -"111111 11WX-6\ 400 RPM 0.4 -` 1 . 3.00 BH' \2.. E0.2 1.50 , BHP `I .\ a BHP 5 BHP 00 I I III 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Airflow(CFM-thousands) RPM=761 BHP= 1.64 Maximum RPM= 1400 Maximum BHP=4.70 Note:Please contact application engineering for selections outside the shaded region. SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.49n Page 7 of 7