Loading...
Report • // cj /71wy TP—PAC, TP—PHP, TP—PRH TP—NAC, TP—NHP, TP—NRH Performance'"' Series Edge' Thermostat Carrier • turn to the expert Product Data per► The Carrier Performance'' Series Edge"' thermostats consists of ' j *•N' programmable and non-programmable air conditioner, heat pump and Thermidistat" controls. These units feature non-mercury, r r t'7 non-lead based electronic controls built into a subtle,slim plastic L enclosure. IIG144 � �! x FEATURES/BENEFITS sL itiU , r ,.; Edge Programmable&Non-Programmable „� • Outdoor Air Temperature(OAT)sensor option 'ct • Auto changeover available } p+ • Battery free ,:42a03 • Non-volatile memory to retain settings during a power outage • Keypad lockout • English/Metric units selection • Filter/UV light/Humidifier pad replacement indicators • Continuous display back-lighting configurable • Hybrid Heat compatible A07049 • RC/RH power compatible Fig.1 - Performance Series Programmable Thermostat • 2-wire communicating installation option Edge Programmable models • ExP" expansion port*for use with future enhancements and/or features • Programmable with personal computer** • 7,5-2,All Days programmable If c • 4 or 2 periods per day programmability IL. ;! t • Programmable fan by period I • Vacation mode controls temperature and humidity • Remote room sensor option ii • Adjusts automatically for Daylight Savings Time Edge Non-Programmable models • Touch•12•Go"' programmability Air Conditioner Control • 1-stage heat/1-stage cool Heat Pump Control • 3-stage heat/2-stage cool A07048 Fig.2-Performance Series Non-programmable Thermostat Thermidistat Control • Heat pump 2-stage or Hybrid Heat 3-stage heat/2-stage US patents:US7287709 n2,us2uuo147242 Al,usDsa2800 SI,US2009ul65 I49 AI, cooling with humidity control US6956467 122. • Humidity display • Humidify output for direct control of humidifier Designed and Assembled • Dehumidify output for variable-speed blowers in the USA. • Hybrid Heat compatible • ExP accessory(expansion port and memory card)sold separately ** Requires ExP accessory MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 T P - P A C 0 1 Product Packaged Quantity T=Thermostat 01 =1 piece Series Equipment Type P=Performance AC=Air conditioning HP=Heat pump Not Defined RH=Relative humidity - =Place Holder Function Type = P=Programmable CC N=Non-programmable Z — 1 O. I Z DIMENSIONS 1 5.2 in. 1.3 i 5.2 in. i 3in. I 33.R2mewj 132.03 mmJ7.0•mm r_ pig.mm V �: ... IJ2.09 mm ,._._—._. ii__ Ii :Z II } ,I_ ill22'.9„I'rj = I CC 5.2 ill 5 2 i° a • 132,03 mni i 132.00 mn _ 1 CL 000 0• i a 1 I '--- Single T..4Siiple Twv Piero Piece Pi c PKu I a A07137 A07138 Fig.3-Performance Series Programmable Thermostat Fig.4- Performance Series Non-programmable Thermostat PRODUCT DATA INFORMATION Wiring Requirements Physical Characteristics Standard 18 to 22 gauge,local wiring codes supersede Dimensions: See drawing Accessories Mounting: Vertical or horizontal J-box provisions PART NUMBER DESCRIPTION Electrical TSTATXXSEN01-B* Outdoor air temperature sensor Input volts/amps: 24VAC,3 VA,RC/R11 compatible TP-EXP ExP Expansion Memory Port Environment TX-LBPOI Large decorative backplate for TP-Pxx and TP-Nxx Operating temperature/Relative humidity: 32°F (0°C) to EDGE-DR-ES05 Espresso Decorative Door 104°F(40°C),95%RH non-condensing -..-- --- Storage temperature/Relative humidity: -40°F (-40°C) to EDGE-DR-GLO5 Gold Luster Decorative Door 134°F(57°C),95%RH non-condensing EDGE-DR-NA05 Natural Grain Decorative Door EDGE-DR-SB05 Saddlebrush Decorative Door EDGE-DR-OX05 Onyx Decorative Door EDGE-DR-QZOS Quartz Decorative Door TX-2WRO5 2-wire harness ZONECCORRSOI Remote room temperature sensor The outdoor air temperature sensor must be used with the Thermidistat control in a Hybrid Heat system. 2 OPERATIONAL INFORMATION Heating/Cooling Setpoints Auto Changeover The heating/cooling setpoint range is from 50°F(10°C)to 90°F When Auto Changeover mode is selected, a change from heat to (32°C). A selectable range of 1-6° is enforced between heating cool(or vice versa)will not occur until an opposite mode demand and cooling desired temperatures. This is done by allowing one has existed for 20 minutes. When a setpoint is changed, Auto • setting to "push" the other, to maintain this difference. (This Changeover timing is ignored to allow the heating/cooling difference is adjustable in Installer settings.) equipment to respond quickly. Auto Changeover mode can be Humidify/Dehumidify Setpoint Range disabled. The humidify setpoint range is from 10% to 46% RH in 2% RH Emergency Heat Mode increments. The dehumidify setpoint range is from 46% to 66% When the thermostat is controlling a heat pump and emergency RH in 2%RH increments. heat is selected, all Y signals are locked out, and W becomes Five-minute Compressor Time Guard energized upon a call for heat. This timer prevents the compressor from starting unless it has been Smart Recovery (Programmable models) off for at least 5 minutes. It can be defeated for I cycle by With Smart Recovery selected, transition out of setback begins a simultaneously pressing the FAN button and INCREASE fixed time period (Off, 30, 60, or 90 minutes selectable) before pc TEMPERATURE(UP)button. selected recovery time and gradually adjusts room temperature so Z Equipment on indicators that the desired temperature will be achieved at selected recovery time. When cooling equipment is ON, a COOL ON icon is displayed. d When heating equipment is ON, a HEAT ON icon is displayed. Room Temperature Offset z When auxiliary heating is ON(HP only), an AUX HEAT icon is Room temperature may be deliberately offset by up to 5° in either l displayed. direction. Humidify/Dehumidify Output On Indicators Programmable Fan (Programmable models) (Thermidistat Control) This selection allows the homeowner to program the fan selection to"Auto"or"Fan On"for each of the program schedule periods. When the operating mode is heat and the HUM output is energized P g� the"humidify"icon shall be displayed.When the operating mode 2 is cool,the dry contact is configured as a DEHUM output and there cc is a dehumidify demand or the cooling equipment is energized to satisfy a dehumidify demand, the "dehumidify" icon shall be • displayed. a a U LaL a H 3