Product Data
per► The Carrier Performance'' Series Edge"' thermostats consists of
' j *•N' programmable and non-programmable air conditioner, heat pump
and Thermidistat" controls. These units feature non-mercury,
r r t'7 non-lead based electronic controls built into a subtle,slim plastic
L enclosure.
IIG144 � �! x FEATURES/BENEFITS
sL itiU , r ,.; Edge Programmable&Non-Programmable
„� • Outdoor Air Temperature(OAT)sensor option
'ct • Auto changeover available
} p+ • Battery free
,:42a03
• Non-volatile memory to retain settings during a power outage
• Keypad lockout
• English/Metric units selection
• Filter/UV light/Humidifier pad replacement indicators
• Continuous display back-lighting configurable
• Hybrid Heat compatible
A07049 • RC/RH power compatible
Fig.1 - Performance Series Programmable Thermostat • 2-wire communicating installation option
Edge Programmable models
• ExP" expansion port*for use with future enhancements and/or
features
• Programmable with personal computer**
• 7,5-2,All Days programmable
If c • 4 or 2 periods per day programmability
IL. ;! t • Programmable fan by period
I • Vacation mode controls temperature and humidity
• Remote room sensor option
ii
• Adjusts automatically for Daylight Savings Time
Edge Non-Programmable models
• Touch•12•Go"' programmability
Air Conditioner Control
• 1-stage heat/1-stage cool
Heat Pump Control
• 3-stage heat/2-stage cool
A07048
Fig.2-Performance Series Non-programmable Thermostat Thermidistat Control
• Heat pump 2-stage or Hybrid Heat 3-stage heat/2-stage
US patents:US7287709 n2,us2uuo147242 Al,usDsa2800 SI,US2009ul65 I49 AI, cooling with humidity control
US6956467 122.
• Humidity display
• Humidify output for direct control of humidifier
Designed and Assembled • Dehumidify output for variable-speed blowers
in the USA. • Hybrid Heat compatible
• ExP accessory(expansion port and memory card)sold separately
** Requires ExP accessory
MODEL NUMBER NOMENCLATURE
1 2 3 4 5 6 7 8
T P - P A C 0 1
Product Packaged Quantity
T=Thermostat 01 =1 piece
Series Equipment Type
P=Performance AC=Air conditioning
HP=Heat pump
Not Defined RH=Relative humidity
- =Place Holder
Function Type
= P=Programmable
CC N=Non-programmable
Z —
1
O.
I
Z DIMENSIONS
1 5.2 in.
1.3 i 5.2 in. i 3in. I 33.R2mewj
132.03 mmJ7.0•mm r_ pig.mm
V �: ... IJ2.09 mm ,._._—._. ii__ Ii
:Z II } ,I_ ill22'.9„I'rj
= I
CC 5.2 ill 5 2 i°
a • 132,03 mni i 132.00 mn
_ 1
CL 000 0• i
a
1
I
'--- Single T..4Siiple Twv Piero Piece
Pi c PKu
I
a
A07137 A07138
Fig.3-Performance Series Programmable Thermostat Fig.4- Performance Series Non-programmable Thermostat
PRODUCT DATA INFORMATION Wiring Requirements
Physical Characteristics Standard 18 to 22 gauge,local wiring codes supersede
Dimensions: See drawing Accessories
Mounting: Vertical or horizontal J-box provisions PART NUMBER DESCRIPTION
Electrical TSTATXXSEN01-B* Outdoor air temperature sensor
Input volts/amps: 24VAC,3 VA,RC/R11 compatible TP-EXP ExP Expansion Memory Port
Environment TX-LBPOI Large decorative backplate for TP-Pxx
and TP-Nxx
Operating temperature/Relative humidity: 32°F (0°C) to EDGE-DR-ES05 Espresso Decorative Door
104°F(40°C),95%RH non-condensing -..-- ---
Storage temperature/Relative humidity: -40°F (-40°C) to EDGE-DR-GLO5 Gold Luster Decorative Door
134°F(57°C),95%RH non-condensing EDGE-DR-NA05 Natural Grain Decorative Door
EDGE-DR-SB05 Saddlebrush Decorative Door
EDGE-DR-OX05 Onyx Decorative Door
EDGE-DR-QZOS Quartz Decorative Door
TX-2WRO5 2-wire harness
ZONECCORRSOI Remote room temperature sensor
The outdoor air temperature sensor must be used with the Thermidistat
control in a Hybrid Heat system.
2
OPERATIONAL INFORMATION
Heating/Cooling Setpoints Auto Changeover
The heating/cooling setpoint range is from 50°F(10°C)to 90°F When Auto Changeover mode is selected, a change from heat to
(32°C). A selectable range of 1-6° is enforced between heating cool(or vice versa)will not occur until an opposite mode demand
and cooling desired temperatures. This is done by allowing one has existed for 20 minutes. When a setpoint is changed, Auto
•
setting to "push" the other, to maintain this difference. (This Changeover timing is ignored to allow the heating/cooling
difference is adjustable in Installer settings.) equipment to respond quickly. Auto Changeover mode can be
Humidify/Dehumidify Setpoint Range disabled.
The humidify setpoint range is from 10% to 46% RH in 2% RH Emergency Heat Mode
increments. The dehumidify setpoint range is from 46% to 66% When the thermostat is controlling a heat pump and emergency
RH in 2%RH increments. heat is selected, all Y signals are locked out, and W becomes
Five-minute Compressor Time Guard energized upon a call for heat.
This timer prevents the compressor from starting unless it has been Smart Recovery (Programmable models)
off for at least 5 minutes. It can be defeated for I cycle by With Smart Recovery selected, transition out of setback begins a
simultaneously pressing the FAN button and INCREASE fixed time period (Off, 30, 60, or 90 minutes selectable) before pc
TEMPERATURE(UP)button. selected recovery time and gradually adjusts room temperature so Z
Equipment on indicators that the desired temperature will be achieved at selected recovery
time.
When cooling equipment is ON, a COOL ON icon is displayed. d
When heating equipment is ON, a HEAT ON icon is displayed. Room Temperature Offset z
When auxiliary heating is ON(HP only), an AUX HEAT icon is Room temperature may be deliberately offset by up to 5° in either l
displayed. direction.
Humidify/Dehumidify Output On Indicators Programmable Fan (Programmable models)
(Thermidistat Control) This selection allows the homeowner to program the fan selection
to"Auto"or"Fan On"for each of the program schedule periods.
When the operating mode is heat and the HUM output is energized P g�
the"humidify"icon shall be displayed.When the operating mode 2
is cool,the dry contact is configured as a DEHUM output and there cc
is a dehumidify demand or the cooling equipment is energized to
satisfy a dehumidify demand, the "dehumidify" icon shall be
• displayed. a
a
U
LaL
a
H
3