Loading...
Report OW2O2/-00z53 q1 % 141ti- IL-VD)/Oo (1.4 COMcheck Software Version COMcheckWeb Interior Lighting Compliance Cer '.; - c5 <4. GINte ir to Project Information II 531` 1 P: ; Energy Code: 90.1 (2019) Standard E , (I I Project Title: T0345 TIGARD OR - ELECTRICAL COMPLIANCE 0'% 4)-09, ri.O Q,^ Project Type: Alteration 'pIALAN 1 10/05/2021 EXPIRES:12.31.2022 Construction Site: Owner/Agent: Designer/Contractor: 9009 SW HALL BLVD TIGARD, Oregon 97223 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed (ft2) Watts /ft2 Watts 1-ACC LOUNGE 189 (Common Space Types:Lounge/Breakroom) 150 0.59 88 2-ROOMS 127,190,191,192 (Common Space Types:Storage >=50- <=1000 1396 0.43 600 sq.ft.) 3-ROOMS 107,126,133,145,188(Common Space Types:Storage>=1000 14523 0.38 5519 sq.ft.) 4-ALL SALES FLOOR(Retail:Sales Area) 92875 1.05 97519 Allowance: Furniture, clothing, cosmetics highlighting/Fix. ID:Track 33800(a) 1.05 2400(b) Allowance:Jewelry, crystal, china highlighting/Fix. ID: Track Lighting 830(a) 1.88 1560(b) Allowance: Vehicles, sporting goods, small electronics highlighting/Fix. 8150(a) 0.45 3668(b) ID: Al 5-COFFEE SEATING 178 (Common Space Types:Dining Area-General) 634 0.43 273 6-COFFEE 186,187 (Common Space Types:Food Preparation) 595 1.09 649 7-GUEST SVC 111 (Common Space Types:Lobby-General) 438 0.84 368 Supplemental Allowed Watts(null) = 1000 Total Allowed Watts = 113643 (a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s) are specified. (b)Allowance is (B x C) or the actual wattage of the fixtures g given in Proposed Power section, whichever is less. (c)Supplemental watts must be associated with retail merchandise highlighting fixtures. Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp/Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. ACC LOUNGE 189 (Common Space Types: Lounge/Breakroom. 150 sq.ft.) LED: A9L6: 4" OPEN RECESSED LINEAR, 6FT: Other: 1 3 33 99 ROOMS 127,190,191.192 (Common Space Types: Storage >=50 - <=1000 sq.ft.. 1396 sq.ft.) Linear Fluorescent: C2: 4' STRIP, STOCK(ETR& RELO): 48"T8 32W: Electronic: 1 2 31 62 Linear Fluorescent: C3: 8' STRIP, STOCK(ETR& RELO): 48"T8 32W: Electronic: 2 10 59 590 LED: C2L: 4' LED STRIP(STOCK ROOMS): Other: 1 3 25 75 LED: C13: 4' LED WET LOCATION (WALK-INS): Other: 1 12 33 396 ROOMS 107,126,133,145.188 (Common Space Types: Storage >=1000 sq.ft., 14523 sq.ft.) Linear Fluorescent: C2: 4' STRIP, STOCK(ETR& RELO): 48"T8 32W: Electronic: 1 5 31 155 Linear Fluorescent: C3: 8' STRIP, STOCK(ETR& RELO): 48"T8 32W: Electronic: 2 141 59 8319 LED: C1L: 4' LED STRIP(CONVEYORS): Other: 1 2 25 50 LED: C2L: 4' LED STRIP(STOCK ROOMS): Other: 1 1 25 25 Project Title: T0345 TIGARD OR-ELECTRICAL COMPLIANCE Report date: 10/05/21 Data filename: Page 1 of 7 COMcheck Software Version COMcheckWeb Exterior Lighting Compliance Certificate Project Information Energy Code: 90.1 (2019) Standard Project Title: T0345 TIGARD OR - ELECTRICAL COMPLIANCE Project Type: Alteration Exterior Lighting Zone 4 (High activity metropolitan commercial district (LZ4)) Construction Site: Owner/Agent: Designer/Contractor: 9009 SW HALL BLVD TIGARD, Oregon 97223 Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts / Wattage (B X C) GPU 4' DRIVE UP DOOR(Drive-up windows/doors) 1 windows 200 No 200 Total Tradable Watts(a) = 0 Total Allowed Watts = 200 Total Allowed Supplemental Watts(b) = 900 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 900 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description / Lamp/Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. GPU 4' DRIVE UP DOOR (Drive-up windows/doors. 1 windows or doors): Non-tradable Wattage LED: H7: LED ARCH WALLPACK: Other: 1 1 45 45 Total Tradable Proposed Watts = 0 Exterior Lighting PASSES Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 90.1 (2019)Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. L'i4v!/U i✓,<niv ' — zLecp"R1CA1 O/o„ "/= -o.2/ Name-Title rr4i) Signature Date Project Title: T0345 TIGARD OR-ELECTRICAL COMPLIANCE Report date: 10/05/21 Data filename: Page 3 of 7 A B C D E Fixture ID : Description / Lamp/ Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. LED: C3L: 8' LED STRIP(STOCK ROOMS): Other: 1 24 49 1176 ALL SALES FLOOR (Retail: Sales Area. 92875 sq.ft.) Track Lighting: Track:A&A TRACK: Wattage based on circuit breaker capacity 0 0 2400 2400 (2e+01 amps x 1e+02 volts) Track Lighting:A&A TRACK: Wattage based on circuit breaker capacity(2e+01 0 0 2400 2400 amps x 1e+02 volts) Track Lighting:A&A TRACK: Wattage based on circuit breaker capacity (2e+01 0 0 2400 2400 amps x le+02 volts) Track Lighting: A&A TRACK: Wattage based on circuit breaker capacity (2e+01 0 0 2400 2400 amps x 1e+02 volts) Track Lighting:A&A TRACK: Wattage based on circuit breaker capacity (2e+01 0 0 2400 2400 amps x le+02 volts) Track Lighting: A&A TRACK: Wattage based on circuit breaker capacity (2e+01 0 0 2400 2400 amps x 1e+02 volts) Track Lighting: A&A TRACK: Wattage based on circuit breaker capacity(2e+01 0 0 2400 2400 amps x le+02 volts) 1 Track Lighting: A&A TRACK: Wattage based on circuit breaker capacity (2e+01 0 0 2400 2400 amps x le+02 volts) Track Lighting: BEAUTY TRACK: Wattage based on circuit breaker capacity(2e+01 0 0 2400 2400 amps x 1e+02 volts) Track Lighting: BEAUTY TRACK: Wattage based on circuit breaker capacity(2e+01 0 0 2400 2400 amps x le+02 volts) LED: Sil: CUSTOM LED PENDANT: Other: 1 3 100 300 LED: D14: 6" LED DOWNLIGHT: Other: 1 11 49 539 LED: RP8: 8' DECO RING PENDANT: Other: 1 2 125 250 LED: RP12: 12' DECO RING PENDANT: Other: 1 1 188 188 LED: Al: 2x4 RECESSED LED RETROFIT(ETR):Other: 1 789 59 46551 LED: SP10: 6' BUSSTRUT LINEAR LED: Other: 1 6 16 96 LED: SP20: 20' PENDANT LINEAR LED, LUXBEAM: Other: 1 6 200 1200 LED: VL2: FOCAL DOWN FIXTURE: Other: 1 76 50 3800 LED: VL3: GONDOLA DOWN LIGHT FIXTURE: Other: 1 133 30 3990 LED: VL4: GONDOLA UP LIGHT FIXTURE: Other: 1 162 30 4860 LED: VL5: COOLER UP LIGHT FIXTURE: Other: 1 35 30 1050 Track Lighting: MARKET TRACK: Wattage based on circuit breaker capacity(2e+01 0 0 2400 2400 amps x le+02 volts) COFFEE SEATING 178 (Common Space Types: Dining Area - General, 634 sq.ft.) LED: D14: 6" LED DOWNLIGHT: Other: 1 15 49 735 LED: D17: 6" LED DOWNLIGHT: Other: 1 1 26 26 COFFEE 186,187 (Common Space Types: Food Preparation. 595 sq.ft.) LED: B2L: 2X4 RECESSED LED: Other: 1 5 40 200 LED: D17: 6" LED DOWNLIGHT: Other: 1 11 26 286 Track Lighting:T2H2 &Tl: STARBUCKS TRACK: Wattage based on 16 feet of track 0 0 480 480 GUEST SVC 111 (Common Space Types: Lobby - General. 438 sq.ft.) LED: B2L: 2X4 RECESSED LED:Other: 1 6 40 240 LED: SR1B: 4" RECESSED LINEAR LED WALL WAS: Other: 1 3 40 120 Total Proposed Watts = 102258 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 90.1 (2019) Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. 1)4 v/0 N4iv/vE - E tecrR/eq L Name-Title LEAD Signature Date Project Title: T0345 TIGARD OR-ELECTRICAL COMPLIANCE Report date: 10/05/21 Data filename: Page 2 of 7 COMcheck Software Version COMcheckWeb Inspection Chec Energy Code: 90.1 (2019) Standard klist Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.lD 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 8.4.1.1, calculations provide all information ODoes Not 8.4.1.2, with which compliance can be 8.7 determined for the electrical systems ONot Observable [PR6]z and equipment and document where ONot Applicable exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. 4.2.2, :Plans, specifications, and/or ❑Complies Requirement will be met. 9.4.3, 9.7 i calculations provide all information ❑Does Not [PR4]1 ;with which compliance can be determined for the interior lighting Not Observable :and electrical systems and equipment ONot Applicable and document where exceptions to :the standard are claimed. Information ;provided should include interior lighting power calculations, wattage of ;bulbs and ballasts,transformers and i control devices. 9.7 Plans,specifications,and/or ❑Complies Requirement will be met. (PR8]i calculations provide all information DDoes Not ;with which compliance can be ;determined for the exterior lighting ONot Observable and electrical systems and equipment ONot Applicable :and document where exceptions to :the standard are claimed. Information ;provided should include exterior lighting power calculations, wattage of :bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: T0345 TIGARD OR-ELECTRICAL COMPLIANCE Report date: 10/05/21 Data filename: Page 4 of 7 Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 8.4.2 At least 50%of all 125 volt 15-and ❑Complies Exception: Space type is not private office, open office, or [EL10]2 20-Amp receptacles are controlled by ODoes Not computer classroom. an automatic control device. ,ONot Observable ❑Not Applicable 8.4.3 New buildings have electrical energy ❑Complies Exception: Requirement does not apply. [EL11]2 use measurement devices installed. ❑Does Not Where tenant spaces exist, each tenant is monitored separately. In ONot Observable buildings with a digital control system ONot Applicable the energy use is transmitted to to control system and displayed graphically. 9.4.1.1 Automatic control requirements ❑Complies Requirement will be met. [EL1]2 prescribed in Table 9.6.1,for the DDoes Not appropriate space type, are installed. ONot Observable Location on plans/spec: See E161 for sensor types.Sales Mandatory lighting controls(labeledfloor lighting controlled via EMS. as'REQ')and optional choice controls ❑Not Applicable (labeled as'ADD1' and 'ADD2') are implemented. 9.4.1.1a Independent lighting controls installed ❑Complies 'Requirement will be met. [EL2]2 per approved lighting plans and all ❑Does Not manual controls readily accessible and visible to occupants. ['Not Observable ONot Applicable , 9.4.1.1b No lighting shall be automatically DComplies Exception: Manual on function would endanger safety and [EL2612 turned on-restriced to manual. ODoes Not security. ONot Observable ONot Applicable 9.4.1.1c <= 50%of general lighting power ❑Complies Requirement will be met. [EL27]2 shall be allowed to be automatically ❑Does Not turned on. ONot Observable ONot Applicable 9.4.1.1d Bilevel lighting control-<= 50%of ❑Complies Requirement will be met. (EL28]2 general lighting controlled with one ODoes Not intermediate step between full off and full on. ❑Not Observable ONot Applicable 9.4.1.1e Automatic daylight responsive ❑Complies Exception: Retail lighting. [EL29]2 controls for sidelighting >= 150 watts ODoes Not controlled by photocontrols. ['Not Observable O Not Applicable 9.4.1.1f Automatic daylight responsive ❑Complies Exception: Requirement does not apply. [EL30]2 controls for toplighting >= 150 watts ODoes Not controlled by photocontrols. ONot Observable ❑Not Applicable 9.4.1.1g Automatic partial OFF: lighting shall ❑Complies Requirement will be met. [EL31]2 be reduced >= 50%within 20 minutes ODoes Not of zero occupancy. ONot Observable O Not Applicable 9.4.1.1h Automatic full OFF: lighting shall be ❑Complies Requirement will be met. [EL32]2 shut off within 20 minutes of zero ODoes Not occupancy. [Not Observable ONot Applicable 9.4.1.1i Scheduled shutoff: all lighting shall be ❑Complies Exception: Lighting in spaces where automatic shutoff would [EL33]2 shut off when scheduled to be ODoes Not endanger the safety or security of the room or building unoccupied. occupants. ❑Not Observable ONot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: T0345 TIGARD OR-ELECTRICAL COMPLIANCE Report date: 10/05/21 Data filename: Page 5 of 7 .. w Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.lO 9.4.1.3 Separate lighting control devices for ❑Complies Requirement will be met. [EL4]1 specific uses installed per approved `❑Does Not lighting plans. ['Not Observable DNot Applicable 9.4.1.4 Automatic lighting controls for exterior,❑Complies Requirement will be met. [EL3]2 lighting installed. ❑Does Not ❑Not Observable :0Not Applicable 9.6.2 Additional interior lighting power DComplies Requirement will be met. [EL8]1 allowed for special functions per the ODoes Not approved lighting plans and is automatically controlled and ❑Not Observable :separated from general lighting. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: T0345 TIGARD OR-ELECTRICAL COMPLIANCE Report date: 10/05/21 Data filename: Page 6 of 7 a Section Final Inspection Complies? Comments/Assumptions & Req.ID 8.7.1 Furnished as-built drawings for ❑Complies Requirement will be met. [FI16]3 electric power systems within 30 days ❑Does Not of system acceptance. ONot Observable ❑Not Applicable 8.7.2 Furnished O&M instructions for ;❑Complies Requirement will be met. [FI17]3 systems and equipment to the ❑Does Not building owner or designated ONot Observable representative. ONot Applicable 9.2.2.3 Interior installed lamp and fixture OComplies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting ?plans, demonstrating proposed watts ONot Observable are less than or equal to allowed ONot Applicable watts. 9.4.2 Exterior lighting power is consistent ❑Complies See the Exterior Lighting fixture schedule for values. [FI19)1 with what is shown on the approved ❑Does Not lighting plans, demonstrating proposed watts are less than or equal ONot Observable to allowed watts. ❑Not Applicable I # 4 9.4.4 At least 75%of all permanently ❑Complies Exception: Requirement does not apply. [FI20]1 installed lighting fixtures in dwelling ❑Does Not units have>= 55 Im/W efficacy or a >= 45 Im/W total luminaire efficacy. ONot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: T0345 TIGARD OR-ELECTRICAL COMPLIANCE Report date: 10/05/21 Data filename: Page 7 of 7 • 11 lampert group 312.522.5835 www.lampertgroup.build Transmittal 10/12/21 DECEIVE D OCT14z i TO: City of Tigard ��y0FTID Planning & Building ;WOW 13125 SW Hall Blvd ODMSION Tigard, OR 97223 From: Leif Erickson Lampert Group LLC 10061 Riverside Dr. #760, Toluca Lake, CA 91602 (312)956-4092 RE: Target - 9009 SW Hall Blvd Tigard Planning and Building, Please find the following plans and application for our project located at 9009 SW Hall Blvd. Quantity Item 6 i Complete set of Plans 2 Structural Calculations 1 Building permit application 1 Set of additional supporting documents Should you have any questions or concerns, please feel free to contact me. Sincerely, Leif Erickson LRE@Iampertgroup.build (312)956-4092 Page 1 of 1