Report • • E1C201 -ov-724 112c10 S 4 )11 Iviv/} Qr.) COMcheck Software Version 4.0.6.1 rno Exterior Lighting Compliance Certificate Section 1: Project Information Energy Code: 2014 Oregon Energy Efficiency Specialty Code Project Title:Jacksons Store No.530 Project Type:New Construction Exterior Lighting Zone: 2 (Residential mixed use area) Construction Site: Owner/Agent: Designer/Contractor: 11290 SW Bull Mountain Road Jacksons Food Stores,Inc., Abossein Engineering Tigard,OR 97224 3450 E. Commercial Ct. 18465 NE 68th St Meridian,ID 83642 Redmond,WA 98052 Section 2: Exterior Lighting Area/Surface Power Calculation A B C D E F Exterior Area/Surface Quantity Allowed Tradable Allowed Proposed Watts Wattage Watts Watts /Unit (B x C) Uncovered Parking(Parking area) 37912 ft2 0.06 Yes 2275 624 Fueling Canopy(Free standing/attached sales canopy) 4352 ft2 0.6 Yes 2611 2240 Store Entry Awning(Entry canopy) 244 ft2 0.25 Yes 61 416 Recycling/Trash(Special feature area) 178 ft2 0.14 Yes 25 158 Total Tradable Watts*= 4972 3438 Total Allowed Watts= 4972 Total Allowed Supplemental Watts**= 600 *Wattage tradeoffs are only allowed between tradable areas/surfaces. **A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Section 3: Exterior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Uncovered Parking(Parking area 37912 ft2):Tradable Wattage LED 1:S1:LED Pole Light:Other: 1 4 139 556 LED 2:S2:LED Bollard:Other: 1 2 34 68 Fueling Canopy(Free standing/attached sales canopy 4352 ft2):Tradable Wattage LED 3:C:Fuel Canopy Fixture:Other: 1 16 140 2240 Store Entry Awning(Entry canopy 244 ft2):Tradable Wattage LED 4:C1:LED Surface:Other: 1 24 17 408 LED 5:C2: LED Surface:Other: 1 2 4 8 Recycling/Trash(Special feature area 178 ft2):Tradable Wattage LED 6:C3: LED Surface:Other: 1 2 79 158 Total Tradable Proposed Watts= 3438 Section 4: Requirements Checklist In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Controls, Switching, and Wiring: ✓ 1. Lighting designated to operate more than 2000 hours per year for Uncovered Parking Areas shall be equipped with motion sensors that will reduce the luminaire power by thirty-three percent or turn off one-third the luminaires when no activity is detected. Project Title:Jacksons Store No. 530 Report date: 10/11/18 Data filename:S:\218120\Calc-Elec\Oregeon Energy Code\LTG Compliance Form.cck Page 4 of 5 Plans reference page/section: E2.0. E4.1 Exterior Lighting Restrictions and Exceptions: p 2. Mercury vapor and incandescent lighting is not permitted for use as exterior lighting. Exception(s): ❑ Incandescent lighting controlled by motion sensors and having total power less than 150 watts. ❑ Incandescent lighting used in or around swimming pools,water features,or other locations subject to the requirements of Article 680 of the National Electric Code. 3. Exempt lighting fixtures are equipped with a control device independent of the control of the nonexempt lighting and are identified in Section 3 table above. Plans reference page/section: Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck Version 4.0.6.1 and to comply wit the mandatory requirements in the Requirements Checklist. Steven Cruz - Electrical Engineer/Designer 10/11/2018 Name-Title Signature Date Project Title:Jacksons Store No. 530 Report date: 10/11/18 Data filename:S:1218120\Calc-Elec\Oregeon Energy Code\LTG Compliance Form.cck Page 5 of 5 COMcheckSoftwareInteriorLighting Version 4.0.6.1 irdly Compliance Certificate Section 1: Project Information Energy Code:2014 Oregon Energy Efficiency Specialty Code Project Title:Jacksons Store No.530 Project Type:New Construction Construction Site: Owner/Agent: Designer/Contractor: 11290 SW Bull Mountain Road Jacksons Food Stores.Inc., Abossein Engineering Tigard,OR 97224 3450 E.Commercial Ct. 18465 NE 68th St Meridian, ID 83642 Redmond,WA 98052 Section 2: Interior Lighting and Power Calculation A B C D Floor Area Allowed Allowed Watts Watts/ft2 Convenience/Fuel Station(Retail) 4217 1.32 5566 Total Allowed Watts= 5566 Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID :Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Convenience/Fuel Station(Retail 4217 sq.ft.) LED 1:BR1:Recessed 2x4:Other: 1 6 54 324 LED 2:BR2:Recessed 2x4 with EM Backup:Other: 1 2 54 108 LED 3:BR3:Recessed 2x2:Other: 1 3 37 111 LED 4:C3:Surface Light:Other: 1 2 79 158 LED 5:E:Vaporproof Freezer/Cooler Light:Other: 1 8 12 96 LED 6:FA1:Surface Wraparound LED 1x4:Other: 1 10 22 220 LED 7:FBI:Surface Mount Cylinder:Other: 1 12 12 144 LED 8:HA1:Cable Hung 1 x4 Linear In/Direct:Other: 1 29 50 1450 LED 9:HB1:Round Pendant:Other: 1 13 5 65 LED 10:HD1:8'Direct Linear Pendant:Other: 1 1 20 20 LED 11:HC1:8'Direct Linear Pendant:Other: 1 5 37 185 LED 12:RA1:Recessed LED:Other: 1 3 22 66 LED 13:J:Coffee Area:Other: 1 2 50 100 LED 14:RB2:4"Round Recessed Wall Wash:Other: 1 2 24 48 LED 15:WA1:6'Direct Linear Wall:Other: 1 1 28 28 LED 16:WB1:3'Direct Linear Wall:Other: 1 4 17 68 Total Proposed Watts= 3191 Section 4: Requirements Checklist In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met.Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. Plans reference page/section'identifies where in 1 the plans/specs the requirement can be verified as being satisfied. Lighting Wattage: i 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Wattage:5566 Proposed Wattage:3191 Complies:YES Mandatory Requirements: Project Title: Jacksons Store No. 530 Report date: 10/11/18 Data filename:S:\2181201Calc-Elec\Oregeon Energy Code\LTG Compliance Form.cck Page 1 of 5 2. Exit signs.Internally illuminated exit signs shall not exceed 5 watts per side. Plans reference page/section: E4.0. E4.1 I/ 3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting in the non-daylight zone.In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided.Automatic daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent,and provide an automatic OFF control, while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e.,north,east, south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration. Plans reference page/section: E4.0 • 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are a remote switch that identifies the lights served and indicates their status. Plans reference page/section: E4.0 D 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room. Plans reference page/section: • 6. Egress lighting.Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during periods that the building space served by the means of egress is unoccupied. Plans reference page/section: E4.0 ❑ 7. Additional controls.Each area that is required to have a manual control shall have additional controls that meet the requirements of Sections 505.2.2.1 and 505.2.2.2. Plans reference page/section: l/ 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either 1)controlling(dimming or multi-level switching)all luminaires;or 2)dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps;or 3)switching the middle lamp luminaires independently of other lamps;or 4)switching each luminaire or each lamp. Plans reference page/section: E4.0 ❑ 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic control device shall function on either: 1)a scheduled basis,using time-of-day,with an independent program schedule that controls the interior lighting in areas that do not exceed 10,000 square feet and are not more than one floor;or 2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space;or 3)a signal from another control or alarm system that indicates the area is unoccupied. Exception(s): ❑ Sleeping units,patient care areas;and spaces where automatic shutoff would endanger safety or security. Plans reference page/section: ❑ 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation. Plans reference page/section: - • 11.An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space. Plans reference page/section: E4.0 ❑ 12.Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and supply rooms up to 1000 square feet. Plans reference page/section: ❑ 13.Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device that:1)is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an override is initiated,and 5)controls an area not exceeding 2,000 square feet. Exception(s): ❑ In malls and arcades,auditoriums,single-tenant retail spaces,industrial facilities and arenas,where captive-key override is utilized,override time is permitted to exceed 2 hours. ❑ In malls and arcades,auditoriums,single-tenant retail spaces,industrial facilities and arenas,the area controlled shall not exceed 20,000 square feet. Project Title:Jacksons Store No.530 Report date: 10/11/18 Data filename:S:12181201Calc-Elec\Oregeon Energy Code1LTG Compliance Form.cck Page 2 of 5 Plans reference page/section: ❑ 14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature that turns off all loads for at least 24 hours,then resumes the normally scheduled operation. Exception(s): ❑ Retail stores and associated malls,restaurants,grocery stores,places of religious worship,theaters and exterior lighting zones. ❑ Single zone electronic time control devices and self-contained wall box preset lighting controls. Plans reference page/section: • 15.Exterior lighting controls.Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a photosensor and a time switch,or an astronomical time switch.Lighting designated for dusk-to-dawn operation shall be controlled by an astronomical time switch or photosensor. Plans reference page/section: E2.0. E2.1. E4.t ❑ 16.Tandem wiring.The following luminaires located within the same area shall be tandem wired: 1. Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet center-to-center of each other. 2.Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted within 1 foot edge-to-edge of each other. Exception(s): ❑ Where electronic high-frequency ballasts are used. ❑ Luminaires on emergency circuits. ❑ Luminaires with no available pair in the same area. Plans reference page/section: ❑ 17.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. Plans reference page/section: ❑ 18.Each dwelling unit in a building is metered separately. Plans reference page/section: Interior Lighting PASSES:Design 43%better than code. Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck Version 4.0.6.1 and to comply with them datory requirements in the Requirements Checklist. Steven Cruz - Electrical Engineer/Designer 10/11/2018 Name-Title Signature Date Project Title:Jacksons Store No. 530 Report date: 10/11/18 Data filename:S:1218120\Calc-Elec\Oregeon Energy Code\LTG Compliance Form.cck Page 3 of 5 1