Loading...
Report tt,ic R Worldwide www.tyco-fire.com Contacts Series TY-B - 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage . General it is recommended that the end-user be consulted about the suitability of these coatings for any given corrosive envi- Description ronment. The effects of ambient tern- , .. The TYCO Series TY-B 2.8, 5.6, perature, concentration of chemicals, { and 8.0 K-factor, Upright, Pendent, and gas/chemical velocity, should be and Recessed Pendent Sprinklers considered as a minimum, along with .' described in herein are standard the corrosive nature of the chemical to response,standard coverage,decora- which the sprinklers will be exposed. ti: tive 5 mm glass bulb-type spray sprin- An intermediate level version of the _, - m klers.They are designed for use in light, Series TY-B Pendent Sprinkler can be ordinary, or extra-hazard commercial obtained by utilizing the Series TY-B occupancies such as banks, hotels, Pendent Sprinkler in combination with shopping malls, factories, refineries, the Model S2 Shield. # fi and chemical plants. l The TY-B Recessed Pendent Sprinkler, NOTICE where applicable,is intended for use in The Series TY-B 2.8,5.6,and 8.0 K fac- r areas with a finished ceiling. It uses a tor, Upright, Pendent, and Recessed y -4 two-piece Style 10(1/2 in.NPT)or Style Pendent Sprinklers described herein 40(3/4 in.NPT)Recessed Escutcheon. must be installed and maintained in , The Recessed Escutcheon provides compliance with this document,as well . 1/2 in. (12,7 mm) of recessed adjust- as with the applicable standards of the ekito ment or up to 3/4 in.(19,1 mm)of total National Fire Protection Association adjustment from the flush pendent (NFPA),in addition to the standards of position. The adjustment provided by any other authorities having jurisdiction. Technical the Recessed Escutcheon reduces the Failure to do so may impair the perfor- accuracy Data to which the fixed pipe drops mance of these devices. to the sprinklers must be cut. The owner is responsible for maintain- Corrosion-resistant coatings, where ing their fire protection system and Approvals applicable, are utilized to extend devices in proper operating condi- FL and C-UL Listed pP P P P 9 FM LPCB,VdS,and NYC Approved the life of copper alloy sprinklers tion. Contract the installing contrac- beyond what would be obtained tor or product manufacturer with any RefertoTableAforcompleteapprovalinfor- when exposed to corrosive atmo- questions. mation,including corrosion-resistant status. spheres. Although corrosion-resistant NFPA 13 prohibits installation of 1l2 in. Maximum Working Pressure coated sprinklers have passed the Refer toTableB standard corrosion tests of the appli- NPT sprinklers with K-factors greater cable a royal agencies, the testingthan 5.6 in new construction. They are Discharge Coefficient is not representative of all possible intended for retrofit in existing sprinkler K=2.B GPM/psi%(40,3 LPM/bar') corrosive atmospheres.Consequently, systems only. K=5.6 GPM/psi''(80,6 LPM/bar") K=8.0 GPM/psi' (115,2 LPM/bar') Sprinkler Temperature Ratings IMPORTANT Identification F Table Refer to Technical Data Sheet Finishes TFP2300 for warnings pertaining to • Numbers (SIN) Sprinkler:Refer to Table C regulatory and health information. Recessed Escutcheon:Signal or Pure White, Always refer to Technical Data TY1151 . . . Upright 2.8K,1/2 in.NPT Grey Aluminum,Jet Black,Chrome Plated, Sheet TFP700 for the "INSTALLER TY1251 . . .Pendent 2.8K,1/2 in.NPT or Natural Brass WARNING" that provides cautions TY3151 . .. Upright 5.6K,1/2 in.NPT Physical Characteristics with respect to handling and instal- Frame Bronze lation of sprinkler systems and corn- TY3251 . . .Pendent 5.6K, 1/2 in. NPT Button Brass/Copper ponents. Improper handling and TY4151 . . . Upright 8.0K,3/4 in. NPT Sealing Assembly..Beryllium Nickel w/TEFLON installation can permanently damage TY4251 ...Pendent 8.0K,3/4 in.NPT Bulb Glass a sprinkler system or its compo- TY4851 . .. Upright 8.0K,1/2 in.NPT Compression Screw Bronze Deflector Copper nents and cause the sprinkler to fail TY4951 . ..Pendent 8.0K,1/2 in.NPT Bushing(K=2.8) Bronze to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 JULY 2018 TFP151 TFP151 Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw jrj'y ' 3 Sealing 6 Defector* Assembly 7 - Bushing ' 7/16" )4 cofi 4 Bulb (111 NAL (57,2/mm)NOMINALMAKE-IN2 *Temperature rating is r I � 4 indicated on Deflector. 2-3/16" 1-9/16" • (55,6 mm) i (39,7 mm) . r 5 ** Pipe thread connections /�1�� + _q Ci-, � 6* per ISO 7-1 can be provided on special 1/2"NPT** I WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE / 1 PI 01,1 mm) NOMINAL 1T 2-3/16" MAKE-IN �I '___ ►9 2 rmr, 2 3/16" �� 4 (55,6 mm) 1 1/2 (38,1 mm) ) _—5 \ � --,_,A=.;-- -z_III .. lit _.. 6* 1/2"NPT** f WRENCH STYLE 10 F-•—2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. 7/16" :\ / 1m11--1-1-- 7 3 -l �� l N1,1 NAL II �� NOMINAL1'- P,� i^^ MAKE-IN 2-3/16 i 11. 2 1 (55,6 mm) rMr 2 3/16" 1_1/2„ 4 (55,6mm) (38,11mm) ,L. 1 �� 5 "���.�i 6* STYLE 10 2-7/8"(73,0 mm)DIA. RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 2 SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE TFP151 Page 3 of 8 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE / i' 1 Y-, � -- 1 3 ' ,7 t (121/mm) 11 11 NOMINAL ��1 I2-5/16' ,�- �A 2 `=, MAKE-IN MI (58,7 mm) —fit Al 2-1/4" 1-9/16" 4 1 (57,2 mm) I (39,7 mm) 5 . II `cJ 3/4" NPT** WRENCH STYLE 40 Y-•-- 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. \\\!_____\ FA 1/2" II. 13 , 3 � � (12,7 NOMINAL ) It d `� • NOMINAL 2-5/16" AAe ! 2 MAKE-IN ir � `I I'\ 1 (58,7 mm) I ` - I I 4 _ 2-1l II /4' 1-9/16" ,�� (57,2I mm) (39,7 mm) .� r=—5 1 j 'AA f STYLE 40 - 2-7/8" (73,0 mm)DIA. - RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 3 SERIES TY-B UPRIGHT(TY4151)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR,3/4 IN.NPT,STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector* r Assembly nrr r �- ,� 4 Bulb 7/16" 2-1/4" I _______ A 3(11,1 mm) I A (57,2 mm) . 2 NOMINAL 1 ► *Temperature rating is MAKE-IN 4 indicated on Deflector. r�r 2-3/16" I � 1-9/16" (55,6 mm) (39,7 mm) S .-- 1 ��5 ** Pipe thread connections \ - - 'i.z per ISO 7-1 can be 1 �+�— 6* provided on special 1/2"NPT** 1 WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE TFP151 Page 4 of 8 2-7/8" DIA. - 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (15,9±6,4 mm) 2-1/4"DIA. 1/4'(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) 1 MOUNTING SPRINKLER PLATE SPRINKLER I PLATE FITTING FITTING / 1/8" / 1/8" 7., (3,2 mm) (3,2 mm) , —•----1 r1 47/ ��� �% 14 , V1�� } } MOUNTING MOUNTING SURFACE _�.--_. , SURFACE , CLOSURE SERIES 1-1/4" (31,8 mm) CLOSURE SERIES 1-5/16"(33,3 mm) 3/4"(19,1 mm) TV-B 13/16"(20,6 mm) FIGURE 5 FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 8.0 K-FACTOR, 3/4 IN. NPT WRENCH G RECESS WRENCH RECESS ioi (END"A"USED FOR ^ 1/2" NPT MODELS) \r WRENCH RECESS (END"8"USED FOR PUSH WRENCH IN TO ENSURE 3/4"NPT MODELS) ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 7 FIGURE 8 W-TYPE 6 W-TYPE 7 RECESSED SPRINKLER WRENCH SPRINKLER WRENCH Poly-Stainless Design Installation Physical Characteristics Frame Button L316 Stainless Steel` Criteria The TYCO Series TY-B 2.8, 5.6, and Bulb Glass 8.0 K-factor, Upright, Pendent, and Compression Screw L316 Stainless Steer The TYCO Series TY-B 2.8, 5.6, and Recessed Pendent Sprinklers must Deflector Copper/Bronze 8.0 K-factor, Upright, Pendent, and be installed in accordance with this Sealing Assembly.Gold Plated BeryllwREFLONl Recessed Pendent Sprinklers are section. 'Type L316 stainless steel(UNS 31603)per ASTM intended for fire protection systems A479/479M or BS EN 1008 WN1.4404. designed in accordance with the Stan- GeneralInstructionsinstallybulb dard installation rules recognized by Do not any bulb type sprinkler _ Operation the applicable Listing or Approval if the bulb is cracked or there is a loss agency, such as UL Listing based on of liquid from the bulb.With the sprin- The glass bulb contains a fluid which the requirements of NFPA 13 and FM kler held horizontally,a small air bubble expands when exposed to heat.When should be present.The diameter of the Approval based on the requirements the rated temperature is reached, the of the FM Global Loss Prevention Data air bubble is approximately 1/16 in. fluid expands sufficiently to shatter the Sheets. Use only the Style 10 or 40 (1,6 mm) for the 135°F (57°C) to glass bulb, allowing the sprinkler to Recessed Escutcheon, as applicable, 3/32 in. (2,4 mm)for the 360°F(182°C) activate and water to flow. temperature ratings. for recessed pendent installations. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Obtain a leak-tight 3/4 in. NPT sprinkler joint by applying a minimum to maximum TFP151 Page 5 of 8 Sprinkler Finish6 Sprinkler Temperature Bulb Wax-Over- K Type RatingLiquid Natural Chrome Lead Wax Color Brass Plated Polyester° Poly-Stainless Coated Coated Lead Coated 135°F(57°C) Orange Upright 155°F(68°C) Red I (TY1151) 1 2 3 d 2.8 and 175°F(79°C) Yellow N/A N/Ad 1/2 in. Pendent NPT (TY1251) 200°F(93°C) Green Figure 1 286°F(141°C) Blue 360°F(182°C) Mauve 1,2 135°F(57°C) Orange Upright 155°F(68°C) Red (TY3151) 1,2,3,5 1,2,3,5 and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2 1,2,3,5 Pendent 200°F(93°C) Green (TY3251) 286°F(141°C) Blue lb,2b,3b,5b 1b,2b,3b,5b 5.6 Figure 2 1/2 in. 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange Recessed 155°F(68°C) Red 1 2,3,4,5 Pendent 175°F(79°C) Yellow 1,2 N/A (TY3251)a Figure 5 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange Upright 155°F(68°C) Red (TY4151) 1,2,3,5 1,2,5 and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2 1,2,5 Pendent 200°F(93°C) Green (TY4251) 1b,2b,3b,5b lb,2b,5b Figure 3 286°F(141°C) Blue 8.0 3/4 in. 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange Recessed 155°F(68°C) Red 1,2,3,4,5 Pendent 175°F(79°C) Yellow 1,2 N/A (TY4251)a Figure 6 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange Upright 155°F(68°C) Red (TY4851) 8.0 and 175°F(79°C) Yellow 1,2,3,4,5,6 N/A N/A 1/2in. Pendent 200°F(93°C) Green NPT (TY4951) Figure 4 286°F(141°C) Blue 360°F(182°C) Mauve NOTES 1. Listed by Underwriters Laboratories,Inc.(UL). 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3. Approved by FM Global(FM Approvals). 4. Approved by the Loss Prevention Certification Board(LPC6 Ref.No.007k/03). 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved.(For details,contact Johnson Controls,Enschede.Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. a Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable b. 150°F(66°C)maximum ceiling temperature c. Frame and deflector only d. Not Applicable(N/A) TABLE A SER/ES TY-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 6 of 8 Sprinkler Finish K Type Chrome Lead Wax Wax-Over-Lead Natural Brass Polyesters Plated Coated Coated Coated 2.8 Upright(TY1151) 1/2 in. and 175 psi(12,1 bar) N/A3 NPT Pendent(TY1251) Upright(TY3151) and 5.6 Pendent(TY3251) 1/2 in. 250 psi(17,2 bar)2 or NPT 175 psi(12,1 bar) Recessed Pendent (TY3251) Upright(TY4151) and 175 psi(12,1 bar) 8.0 Pendent(TY4251) 3/4 in. NPT Recessed Pendent (12,1 psi 175bar) N/A 8.0 Upright(TY4851) 1/2 in. and 175 psi(12,1 bar) NPT Pendent(TY4951) NOTES 1. Frame and deflector only 2. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL),the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL),and the Approval by the City of New York. 3. Not Applicable(N/A) TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE torque of 10 to 20 lb-ft (13,4 to Step 3. Tighten the sprinkler into the After Installation 26,8 N.m). Higher levels of torque may sprinkler fitting using only the W-Type After installation, complete the distort the sprinkler inlet and cause 6 Sprinkler Wrench (Ref. Figure 7). following: leakage or impairment of the sprinkler. For wax-coated sprinklers, use an • Inspect the sprinkler wrench flats Do not attempt to compensate for 8 or 10 in. adjustable wrench. With and frame arms and retouch(repair) insufficient adjustment in the escutch- reference to Figure 1 to 4, apply the the wax coating whenever the coat- eonplate byunder- or over-tightening W-Type 6 Recessed Sprinkler Wrench g g or an adjustable wrench,as applicable, ing has been damaged and bare the sprinkler. Re-adjust the position of to the sprinkler wrench flats, metal is exposed. the sprinkler fitting to suit. • Retouch the wax coating on the Series TY-B Upright and Pendent Wax Coated Sprinklers wrench flats by gently applying a Sprinklers Installation When installing wax-coated sprinklers P with an adjustable wrench,take care to heated 1/8 inch diameter steel rod The Series TY-B Upright and Pendent prevent damage to the wax coating on to the damaged areas of wax, to Sprinklers must be installed in accor- the sprinkler wrench flats or frame arms smooth it back over areas where dance with the following instructions: and, consequently, exposure of bare bare metal is exposed. Step 1. Install pendent sprinklers in the metal to the corrosive environment: pendent position. Install upright sprin- NOTICE Open klers in the upright position. Open the jaws of the wrench suffi- ciently wide to pass over the wrench Only retouching of the wax coating applied to the wrench flats and frame Step 2. With pipe thread sealant flats without damaging the wax arms is permitted, and the retouching applied to the pipe threads, hand- coating. tighten the sprinkler into the sprinkler is to be performed only at the time of fitting. • Before wrench tightening the sprin- the initial sprinkler installation. kler, adjust the jaws of the wrench The steel rod should be heated only to to contact only the sprinkler wrench the point it can begin to melt the wax, flats. and appropriate precautions need to be • After wrench tightening the sprin- taken when handling the heated rod in kler, loosen the wrench jaws before order to prevent the installer from being removing the wrench. burned. TFP151 Page 7 of 8 Series TY-B Recessed Pendent Care and Automatic sprinklers must never be Sprinklers painted, plated, coated, or other- The Series TY-B Recessed Pendent wise altered after leaving the factory. Sprinklers must be installed in actor- MalnfenanCe Modified sprinklers must be replaced. dance with the following instructions: The TYCO Series TY-B 2.8, 5.6, and Sprinklers that have been exposed to corrosive products of combustion,but Step 1. After installing the Style 10 8.0 K-factor, Upright, Pendent, and have not operated,should be replaced or 40 Mounting Plate, as applicable, Recessed Pendent Sprinklers must be if they cannot be completely cleaned over the sprinkler threads and with maintained and serviced in accordance by wiping the sprinkler with a cloth or pipe thread sealant applied to the pipe with this section. by brushing it with a soft bristle brush. threads,hand-tighten the sprinkler into Before closing a fire protection system Care must be exercised to avoid the sprinkler fitting. main control valve for maintenance damage to the sprinklers before, Step 2. Tighten the sprinkler into the work on the fire protection system during, and after installation. Sprin- sprinkler fitting using only the W-Type that it controls, obtain permission to klers damaged by dropping, striking, 7 Recessed Sprinkler Wrench (Ref. shut down the affected fire protection wrench twist/slippage,or the like,must Figure 8).With reference to Figure 3 or system from the proper authorities be replaced.Also,replace any sprinkler 4,apply the W-Type 7 Recessed Sprin- and notify all personnel who may be that has a cracked bulb or that has lost kler wrench to the sprinkler wrench affected by this action. liquid from its bulb.Refer to the Instal- flats. The owner must assure that the sprin- lation Section. Step 3.After the ceiling is installed or klers are not used for hanging any The owner is responsible for the the finish coat is applied, slide on the objects and that the sprinklers are only inspection, testing, and maintenance Style 10 or 40 Closure over the Series cleaned by means of gently dusting of their fire protection system and TY-B Recessed Pendent Sprinkler with a feather duster; otherwise, non devices in compliance with this dot and push the Closure over the Mount- operation in the event of a fire or inad- device as well as with the applicable ing Plate until its flange contacts the vertent operation may result. standards of the National Fire Protec- ceiling. Absence of an escutcheon, which is tion Association,(e.g., NFPA 25), in used to cover a clearance, may delay addition to the standards of any other the time to sprinkler operation in a fire authorities having jurisdiction.Contact situation. the installing contractor or product Sprinklers which are found to be manufacturer with any questions. leaking or exhibiting visible signs of Automatic sprinkler are recommended corrosion must be replaced. to be inspected,tested,and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFP151 Page 8 of 8 P/N 57 — XXX — X — XXX SIN SPRINKLER TEMPERATURE FINISH RATING 530 2.8K UPRIGHT(1/2 in.NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2 in.NPT) TY1251 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 POLYESTER 570 5.6K UPRIGHT(1/2 in.NPT) TY3151 175 175°F(79°C) 3 PURE WHITE(RAL9010)2 571 5.6K PENDENT(1/2 in.NPT) TY3251 POLYESTER 200 200°F(93°C) 4 SIGNAL WHITE(RAL9003) 590 8.0K UPRIGHT(3/4 in.NPT) TY4151 POLYESTER 286 286°F(141°C) 5 JET BLACK(RAL9005)a 591 8.0K PENDENT(3/4 in.NPT) TY4251 POLYESTER 360 360°F(182°C) 6 WAX COATED 286°F(141°C)MAX 000 OPEN° 560 8.0K UPRIGHT(1/2 in.NPT) TY4851 7 LEAD COATED 561 8.0K PENDENT(1/2 in.NPT) TY4951 8 WAX-OVER-LEAD 286°F(141°C)MAX 9 CHROME PLATED NOTES 1. Only available on TY3151,TY3251,TY4151,and TY4251. 2. Eastern Hemisphere sales only. 3. Available in only 8.0K,155°F(68°C)or 200°F(93°C);requires lead time to manufacture. 4. Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems("OPEN"indicates sprinkler assembly without glass bulb,button,and sealing assembly). TABLE C SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56 000-6-387 Warranty Specify: W-Type 7 Sprinkler Wrench, For warranty terms and conditions,visit P/N 56-850-4-001 www.tyco-fire.com. Wax Sticks(for retouching wrench- Ordering damaged wax coating) 9 Specify: (specify color, below) Color- coded Wax Sticks for retouching Procedure (specify temperature rating) tempera- Contact your local distributor for avail- ture-rated Series TY-B Sprinklers,P/N ability.When placing an order,indicate (specify) the full product name and Part Number Black for 135°F(57°C) P/N 56-065-1-135 (P/N) Red for 155°F(68°C) P/N 56-065-1-155 Yellow for 175°F(79°C) P/N 56-065-1-175 Sprinkler Assemblies with Blue for 200°F(93°C) NPT Thread Connections and 286°F(141°C) P/N 56-065-1- Specify: Series TY-B (specify SIN), 266 (specify K-factor), (specify Upright Note: Each wax stick is suitable for or Pendent) Sprinkler with (specify) retouching up to 25 sprinklers. temperature rating, (specify) finish or The wax used for 286°F(141°C)sprinklers coating, P/N(Refer to Table C) is the same as for 200°F(93°C)sprinklers. Recessed Escutcheon Therefore, the 286°F (141°C) sprinkler Specify: Style (10 or 40) Recessed is limited to the same maximum ceiling Escutcheon with (specify°) finish, P/N temperature as the 200°F(93°C)sprinkler (specify') which is 150°F(66°C). •Refer to Technical Data Sheet TFP770 1400 Pennbrook Parkway,Lansdale,PA 19446I Telephone.1-215-362-0700 �' 02018 Johnsen Controls.All rights reserved.All specifications end ether information shown were current as of document revision dale and are subitcl to change without notice. Johnson 7/ �' NATIONAL FIRE PROTECTION ASSOCIATION and NFPAare rapnereA vademeMc of National Pre Protection Aaaocia1ion', Cools TEFLON is a registered trademark of DuPont t Controls 1tr MI16. Bulletin 060 September 2019 Model F3-80 Dry co iii r bid K8.0 (i :: nse, 15tric) 0 Standard Spray Sprinklers co Features 0 1. Available in the following configurations: r-H ry • Pendent with standard escutcheon 1 • Pendent with Model HB extended escutcheon • Pendent with Model FP recessed escutcheo4 ,, , n"j • Concealed Pendent with Model CCP cover plate ) • Horizontal Sidewall with Standard escutcheon iit - • Horizontal Sidewall with Model HB extended es- cutcheon Standard Escutcheon HB Escutcheon • Horizontal Sidewall with Model FP recessed es- (See Fig. 1) (See Fig.2) cutcheon 2. Available with 1" NPT or ISO7-1 R1 inlet fitting. 0.,, 3. Sprinklers, escutcheons, and cover plates are avail- k f. able in a wide variety of standard and special appli- z cation finishes. 4. White polyester and black polyester finish sprinklers ' are cULus Listed as Corrosion Resistant. Product Description Model F3-80 Dry sprinklers are standard-response, standard coverage sprinklers with a nominal K-Factor of FP Recessed Escutcheon CCP Cover Plate 8.0 (115 metric). Model F3-80 Dry sprinklers all use a 5 (See Fig.3) (See Fig.4) mm glass bulb operating element. See the Temperature Ratings table in this Bulletin for available temperature rat- ings. Model F3-80 Dry sprinklers are intended for installa- tion on wet pipe, dry pipe,or preaction sprinkler systems in accordance with NFPA 13. �' ,f K, Model F3-80 Dry sprinklers are available with a variety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 7. In addition, Model F3-80 Dry Pendent sprinklers are also available with the Model CCP Horizontal Sidewall Horizontal Sidewall I HB conical concealed cover plate as illustrated in Fig. 4. (See Fig.5) (See Fig. 6) Available sprinkler, escutcheon, and cover plate finishes are identified in the Finishes table in this Bulletin. The Model FP escutcheon, and Model CCP cover plate are the only recessed escutcheons and cover plate listed for f 1 ?So use with Model F3-80 Dry sprinklers;the use of any other recessed escutcheon or cover plate with Model F3-80 �" Dry sprinklers will void all guarantees,warranties, listings , and approvals. Recessed FP Inlet fittings are available with 1" NPT or ISO 7-1R1 Horizontal Sidewall threads. (See Fig. 7) See the Available Configurations, Listings, and Approv- als table in this Bulletin for further information on Model F3-80 Dry sprinklers. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Available Configurations, Listings, and Approvals Sprinkler Escutcheon or Available Length Listings and Inlet Sprinkler Identification Model Cover Plate (See Figs.1 -7) Approvals"' Threads Number(SIN) Standard 2"to 36" F3-80 Dry Escutcheon (50 to 914 mm) 1"NPT Pendent HB Extended Escutcheon cULus,NYC or RA6012 FP Recessed Escutcheon 3-1/2"to 36" IS07-1 R1 CCP Cover Plate (90 to 914 mm) F3-80 Dry Standard Escutcheon 2"to 36" 1"NPT Horizontal (50 to 914 mm) cULus'2',NYC(2) or RA6032 Sidewall HB Extended Escutcheon 3-1/2"to 36" IS07-1R1 FP Recessed Escutcheon (90 to 914 mm) "'For available temperature ratings and finishes see the Temperature Ratings and Finishes tables,respectively,in this Bulletin, (2)cULus Listing and NYC for Light Hazard(existing)and Ordinary Hazard only. Patents Model F3-80 Dry series sprinklers may be covered by one or more of the following patents: US Patent No. 5,775,431 US Patent No. 5,967,240 Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada(cULus) 2. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Maximum Listed and Approved Working Pressure: 175 psi (12 bar) Nominal K-Factor: 8.0 gpm/psi12(115 L/min/bar112) Temperature Glass Bulb Color Sprinkler Cover Plate Maximum Ceiling Listings and Classification Temperature Rating Temperature Rating Temperature Approvals"' Ordinary Orange 35°F(57°C) 135°F(57°C) 100°F(38°C) Red 155°F(68°C) Intermediate Yellow 175°F(79°C) 165°F(74°C) 150°F(66°C) cULus,NYC Intermediate Green 200°F(93°C) 165°F(74°C) 150°F(66°C) High Blue 286°F(141°C) None 225°F(107°C) 165°F(74°C) 150°F(66°C) (1(For listed and approved sprinkler,escutcheon,and inlet configurations see the Available Configurations,Listings,and Approvals table in this Bulletin, Finishes Component Sprinkler Escutcheonm Cover Plate Bronze Brass'3' White Paint Standard Finishes White Polyester'2' White Polyester Chrome Chrome Chrome Electroless Nickel PTFE'2' Black Polyester(2) Custom Color Polyester Satin Chrome Wax Coated"' Electroless Nickel PTFE Black Paint Special Application Finishes High Temp.Wax Coated's' Black Polyester g Customer Color Polyester Custom Color Paint y - Lead Plated147 Black Plating Wax Over Lead'4' High Temp.Wax Over Lead's' - (')Standard and Model HB escutcheons are supplied with both the can and escutcheon finished.Model FP escutcheons are supplied with the escutcheon finished;the cup is galvanized steel with no further finish. 121 cULus Listed as a Corrosion Resistant Sprinkler. "'Brass finish available for standard Model FP escutcheons only. '4)Wax coating,lead plating,and wax over lead finishes are Listed and available for 155°F(68°C), 175°F(79°C),and 200°F(93°C)activation temperature sprinklers only. Is'High temperature wax coating and high temperature wax over lead finishes are Listed and available for 286°F(141°C)activation temperature sprinklers only and shall only be installed where maximum ceiling temperature does not exceed 150°F(66°C). 2. Model F3-80 Dry Pendent Sprinkler with Standard Escutcheon (SIN RA6012) "A"Dim. 12"to 36"(51mm to 914mm)in 1/4"(6mm)increments I 11111 f ''III (, I I System Fitting Inlet Fitting 2-1/8" — "A" Dimension [54mm] Dia. Hole in Ceiling 1-1/4" / Sprinkler Can [32 mm] ✓// Escutcheon I Adjustment Escutcheon r/ 5/32" ceiling li [12mm] / 1 Nominal Escutcheon Position / { �J 1/4" [6 mm] 1-5/8" Escutcheon Adjustment \ [41 mm] 1/4" [6 mm] Nominal Protrusion I 3[76 mm] COMDRYDET1 DIA. Fig. 1 ' Note:The sprinkler can protrudes V 'when escutcheon is in nominal position. Escutcheon adjustment provides'/a"(-6mm)to+1 Y4" (+32mm)"A" dimension adjustment range. Sprinkler Guard: Model C2 3. Model F3-80 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN RA6012) "A"Dim. 1372"to 36"(89mm to 914mm)in 1/4"(6mm)increments 1 Ifp f , 1 System tee L. i f Inlet fitting L "A" Dimension 2-1/2" [64 mm] Dia. Hole in Ceiling r 1/2" [13mm] Escutcheon Adjustment ? „ 1-1/4" 1 [32mm] Nominal Position Escutcheon of' Escutcheon I Sprinkler Can 1/2" [13mm] Escutcheon Adjustment 4. i CL(J 1 li,'"12/ COMDRYDET2 3-1/2" [89 mm] Escutcheon Dia. Fig. 2 Note: The sprinkler can protrudes 1 Ya"when escutcheon is in nominal position. Escutcheon adjustment provides'/e"(-12.7mm)to+1"(+12.7mm) "A"dimension adjustment range. 4. Model F3-80 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN RA6012) "A"Dim. 3V2"to 36"(89mm to 914mm)in 1/4"(6mm)increments -z_ s- i I I I II II IH - ql i_s 1 _ r_�� =1 lI II—=1 l L_I—=I_J System Tee A .„ I Inlet Fitting 1 2-5/8" [67 mm] Dia. "A" Dimension Hole in Ceiling 1I 1 Sprinkler I Cup 1/4" [6mm] Escutcheon Adjustment Escutcheon I - 1 \ Ceiling 3111 . - 1111 1IIY_ 1- I 3/4" [19 mm] Nom. Nominal Escutcheon Position 3 7l32" 1/4" [6 mm] Escutcheon Adjustment [82 mm] Dia. COMDRYDET3 Fig. 3 Note:Do not install the Model F3-80 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. 5. Model F3-80 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN RA6012) "A"Dim. 3'k"to 36"(89mm to 914mm)in 1/4"(6mm)increments rz s� ice- --- i--- i i i 1 i a� — III t ;— — i l j— V� ,l it i�iInl i riii I 1I---_L�iS' __-1 r�-___ 1TL J _ i I) I==1=1 H I� '_ '- System Tee " Inlet Fitting 2-1/2" [64 mm] Dia. "A" Dimension Hole in Ceiling Sprinkler Cup 3/16" [5 mm] Model CCP 1/2 Cover Plate Adjustment WE- / Cover Plate Assembly Ceiling__,._) opt, aug 1/? I 7/8" I MI Nominal Cover -- [22 mm] Plate Position 3/16" [5 mmj Cover Plate Adjustment 3-5/16" [84 mm] Dia. COMDRYDET4 Fig. 4 Note:Do not install the Model F3-80 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above. 6. Model F3-80 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN RA6032) °A"Dim. 2' to 48"(51mm to 1219mm)in 1/4"(6mm)increments for 1'connections or 2"to 36"(51mm to 914mm)in 1/4"(6mm)increments for 3/4"connections S Ceiling 4" [102 mm] Min. 12"[305 mm] Max. 15/32" [12mm] Sprinkler Can 2-3/32" System Fitting f [53 mm] n Inlet Fitting _ _ alsor I,I - I ,i 5/8" [16 mm] r II ►I 3 [76 mm] I III 2-1/8 [54 mm] Dia. 1/4" [6mmj Nominal Protrusion Hole in Wall 1/4" [6 mm] Escutcheon Adjustment COMDRYDET6-80 • 1-1/4" [32 mm] Nominal Escutcheon Position Escutcheon Adjustment -- "A"Dimension Fig.5 Note:The sprinkler can protrudes 1/4"when escutcheon is in nominal position. Escutcheon adjustment provides'/d"(-6mm)to+11/4' (+32mm)"A" dimension adjustment range. 7. Model F3-80 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN RA6032) "A"Dim. 3yz'to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections Ceiling m 4"[102mm] Min. —Escutcheon 12"[305mm] Max. Sprinkler Can 2 3/32" System Tee Inlet Fitting [53mm] T — ! Th ---1 5/8"[16mm] 3-1/2" — — — — — 5 `� [89mm] \ Escutcheon Dia. 2 1/2" Dia. [ / [64mm] 1-1/4" 1-1/4"[32mm] Nominal Protrusion Hole in Wall [32mm] 1/2"[13mm] Escutcheon Adjustment • COMDRYDET7-Bo 1/2"[13mm] Nominal Position Escutcheon of Escutcheon Adjustment I- "A"Dimension - Fig. 6 Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides /2"(-12.7mm)to+ye"(+12.7mm) "A"dimension adjustment range. 8. Model F3-80 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN RA6032) "A"Dim. 3'/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections r Ceiling ,�J Nom. 1-1/4" i ! Escutcheon [32 mm] 4"[102 mm]Min. Sprinkler Cup to i cULus,NYC:6"[152 mm]Max. System Tee FM: 12"[305 mm] Max. Inlet Fitting ��i_—sue ��_ 1 „/, 'IIIIII�III1 Li! ; l I — 3 7/32 _ ! [82 mm]Dia. t 2-1/2" - [64 mm]Dia. Hole in Wall 1/4"[6 mm] Escutcheon Adjustment COMDRYDETB-BO 1/4"[6 mm] "- • Nominal Escutcheon Position Escutcheon Adjustment "A"Dimension i Fig. 7 - Note:Do not install the Model F3-80 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. 9. MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM NOTE: STANDARD DRY PENDENT IS SHOWN, HOWEVER, MINIMUM EXPOSED BARREL LENGTH APPLIES TO ALL STYLES OF DRY SPRINKLERS CONNECTED -0 A WET PIPE SYSTEM. WET PIPE EXPOSED BARREL TEMPERATURE 40F/4'C • 1.. - ---fi---_rJ-1,i�,---G1)I AMBIENT AMBIENT TEMPERATURE --IR,IInII EXPOSED TO 5DT/I CPC 6PF/16'C - '•I �I�Ik DISCHARGE END EXPOSED MIN MUM BARREL LENGTH.. - I--L-1- -•.,.,, OF SPRINKLER•(F ACE OF FITTING TO TOP OF CEILING)••• _�I _ IN. NM) IN. (MM) IN. NM) _ _ -�� 407(4C) 0 0 D 5 30'F(-VC) 0 0 0 IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY 20'F(-Y'C) 4(100) 0 0 Ell IF CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING 10T(-12'C) 8(200) I (25) 0 TAPE OR EQUIVALENT 0'F(-16'C) 12(SOS) 3(75) 0 MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE -10'F(-23'C) l4(350) 4(t00) I (25) EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED -20'F(-20C) 14(350) 6(150) 3(75) LENGTH AREA AND CONSEQUENT FORMATION OF •A" CONDENSATE AROUND THE FRAME, WHICH -3GF(-340) 16(400) B(DOD) 4(100) DIMENSIONCLEARANCE COULD INHIBIT OPERATION OR CAUSE HOLE PREMATURE OPERATION. SEE BELOW FOR -40T(-40O) 18(450) 8(200) 4(100) RECOMMENDED METHODS. -50T(-46C) 20(50D) 10(250) 6(150) -50'F(-51'C) 20(500) 10(250) 6(150) •FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE ® L INSIDE SURFACE OF END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES 4EBEBBEEBEICELINGTION,WALL. OR LISTED, USE THE NEXT COOLER TEMPERATUREEEEEEEEEB ••THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE I A"BASED DIMENSION. THE R MS LEDEXPOSEDBARREL LENGTHMVP. ISU BASED EL A PROPERLY SEALED PENETRATIONSPRINER WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF 30 MPH(98 KM/H). LONGER EXPOSED BARREL LENGTHS WLL THERMAL 111 ESCUTCHEON HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER BARRIER Y,,,I VANS VELOCITY IS EXPECTED. III■ •••THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED i DISCHARGE END OF SPRINKLER FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION, WALL. OR CE_NC LEADING TO THE COLD SPACE, PROTECTED(NON-CONDITIONED) AREA) WHICHEVER IS CLOSEST TO THE FITTING. RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) .- _--iBD WET PIPE -- rt T F� -TO /y" y ==E�__J 5hk=- 'y--- L-r-1__r_zC - lFrv--X L--�I --- -' 1 r—1 r_iJ ram: L MINIMUM ®' (HEATED AREA) (HEATED AREA) LE1'J EXPOSED I MINIMUM BARREL I EXPOSED LENGTH DECKTITE FLASHING fr. INSIDE FACE SEAL BARREL LENGTH (SEE ABOVE) R(RECOMMENDEO) �� 7 � � (SEE ABOVE) CLEARANCE HOLE 2 INSULATED FREEZER, I• I I- OR COOLER STRUCTURE OR EXTERIOR FRAMING o. AIN INNIAr ArArArA: !I A 1111111.11.1111. "MM. iamm iiimim (PROiEC1EO AREA) hi 0011 V DISCHARGE END IN SPRILO NKLER OF (PROTECTED AREA) `I'IO DRY DISCHARGE ENO COLD RIAREAR OF Y=y COMDRYDET1 Fig. 8 10. *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction;this will damage the sprinkler,the fitting,or both. Short inlet("PL")versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet("PL") should only be installed in CPVC fittings of wet-pipe systems. In all cases,verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal No Internal - Obstruction Obstruction I Female Female _________ Pipe Pipe / / Thread Thread et 0 CPVC itting - CPVC Fitting with Internal Obstruction No Internal Obstruction Shorter 1 Longer all Inlet Inlet Male 1 __ Male Pipe Pipe TiThread IIIII Thread ________ro,__ ___,---------,— _-_-_. PIP Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION GOMDRYDET2 Fig.9 11. ){ {IBC 71...,. 4 Fig. 10-Model F3R Wrench t 4w, h ttY . eF r _.. ,J Sj lr • r.. 4 Fig. 11 -Model XLO2 Wrench 12. MATERIAL SPECIFICATIONS ITEM# DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 \- 3 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 _s 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 0 in lit5 BULB INSERT COPPER ALLOY PER UNS C31400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION - 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 F [ ■ 0 8 OUTER TUBE GALVANIZED STEEL II 9 INNER TUBE BRASS ALLOY PER UNS C23000 1 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 7 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL -/ 0 14 FLIP DISK BRASS ALLOY PER UNS C54400 PAINTED OR PLATED MILD STEEL / I 15 CAN/ESCUTCHEON (NOT USED ON ALL MODELS) 0 / ® (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) 7 I il 11 COMDRYDETI3 0 MNI\1 0 © 1./‘. O t APPEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL © H\\\O.N \\\\\\ Fig. 12 13. Installation Instructions Model F3-80 Dry sprinklers must only be installed in the should be taken to prevent damage to the sprinkler. following fittings: The sprinkler is then tightened into the pipe fitting to 1. The side outlet of an ANSI B 16.3 class 150(malleable achieve a leak free connection. The recommended or ductile) or ANSI B16.4 class 125 (cast) iron pipe minimum to maximum installation torque is 22-30 lb- tee ft(30-40 N-m). 2. The run outlet of an ANSI B 16.3 class 150(malleable 3a.Alternatively, where access to the outer tube of the or ductile) or ANSI B16.4 class 125 (cast) iron pipe sprinkler is available, the Model F3-80 Dry sprin- tee, with the side outlet plugged (wet-pipe systems kler may be installed using a pipe wrench. The only) pipe wrench shall only be permitted to interface 3. Spears Manufacturing Company Brass Thread In- with the galvanized steel outer tube portion of the sert Style or Special Reinforced Plastic Thread Style sprinkler (Item #8 in Fig. 12). Do NOT wrench any Listed adapter or tee (wet-pipe systems only) (gasket other portion of the sprinkler assembly. A pipe sealed outlets shall not be used) wrench can install the sprinkler into the fitting with 4. Any Listed CPVC sprinkler adapter or tee only in ac- a large amount of torque; consideration should be cordance with Fig. 9 and upon verification that the given to the need for future removal of the sprin- CPVC adapter or tee does not interfere with the sprin- kler because the installation torque will have to be kler's inlet (wet-pipe systems only) (gasket sealed matched or exceeded to remove the sprinkler.The outlets shall not be used) recommended minimum to maximum installation Model F3-80 Dry sprinklers must not be installed into cou- torque is 22- 30 lb-ft(30-40 N-m). plings, elbows, welded outlets,or gasket sealed outlets. In- 4. Standard and Model HB escutcheons can be in- stallation of the Model F3-80 Dry sprinkler is not recommend stalled by slipping the escutcheon over the can until in copper pipe systems, as this may reduce the life expec- the escutcheon is seated against the ceiling or wall. tancy of the sprinkler. The Model FP escutcheon is installed by pressing In all dry-pipe system installations, the Model F3-80 Dry or threading the escutcheon into the cup by hand; sprinkler must be installed with protrusion into the fitting in the escutcheon can be tightened against the ceiling accordance with Fig. 1 through Fig.7 in this Bulletin. Do not or wall by turning the escutcheon in a clockwise di- install Model F3-80 Dry sprinklers with the standard (long) rection and removed by turning the escutcheon in a inlet fitting into CPVC fittings that have an internal obstruc- counter-clockwise direction. To install the Model CCP tion (see Fig. 9);this will damage the sprinkler, the fitting, or cover plate,first remove the protective clip. Install the both. Model F3-80 Dry sprinklers are available with a short Model CCP cover plate on the sprinkler by pressing "PL" inlet fitting for installation on CPVC fittings of wet-pipe or threading the cover plate into the cup by hand;the sprinkler systems only. cover plate can be tightened against the ceiling by Model F3-80 Dry sprinklers connected to wet-pipe sys- turning the cover plate in a clockwise direction and tems must be installed with the Exposed Minimum Barrel removed by turning the cover plate in a counter- Length required by Fig.8 located in a Heated Area. clockwise direction. An orange protective clip is factory installed on the sprin- 5. Remove the orange protective clip when placing the kler to protect the glass bulb thermal element from dam- sprinkler system in service. age. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service. Use the following steps for installation: 1. Cut a hole in the wall or ceiling directly in-line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the es- cutcheon or cover plate option selected. 2. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler's inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3R wrenches are designed to be inserted into the groves in the sprinkler's wrench boss as shown in Fig. 10. The Model XLO2 wrench is designed to fit into the cup and engage the wrench boss as shown in Fig. 11. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When insert- ing or removing the wrench from the sprinkler, care 14. Installation Data Sprinkler Model Escutcheon or Cover Plate Suggested Hole Diameter in Wall or Ceiling Installation Wrench Standard Escutcheon 2-1/8"(54 mm) F3R HB Extended Escutcheon 2-1/2"(64 mm) F3-80 Dry FP Recessed Escutcheon 2-1/2"(64 mm) XL02 CCP Cover Plate(Pendent Only) Maintenance Ordering Information The Model F3-80 Dry Sprinklers should be inspected and the Specify: sprinkler system maintained in accordance with NFPA 25. 1. Sprinkler: [Model F3-80 Dry Pendent SIN RA6012] Do not remove the factory applied thermally sensitive wax [Model F3-80 Dry Horizontal Sidewall SIN RA6032] fillet between the bulb supporting cup and the wrenching 2. Escutcheon/Cover Plate: [None][Standard escutch- boss. Do not replace this wax with a substitute substance. eon][Model HB extended escutcheon][Model FP re- An Alternate substance may interfere with proper operation cessed escutcheon][Model CCP cover plate - pen- of the sprinkler. Do not clean sprinklers with soap and water, dent only] ammonia or any other cleaning fluids. Remove dust by us- 3. Inlet Threads: [1" NPT][ISO7-1R1] ing a soft brush or gently vacuuming. Replace any sprin- 4. Inlet Fitting: [Long -Standard Inlet Fitting][Short "PL" kler which has been painted (other than factory applied) or -Wet Pipe Systems only] damaged in any way.A stock of spare sprinklers should be 5. Sprinkler Temperature Rating: See Temperature Rat- maintained to allow quick replacement of damaged or op- ings table erated sprinklers. Prior to installation, sprinklers should be 6. Sprinkler Finish: See Finishes Table maintained in the original cartons and packaging until used 7. Escutcheon/Cover Plate Finish: See Finishes Table to minimize the potential for damage to sprinklers that would 8. Length: "A" Dimension (face of tee to face of ceiling cause improper operation or non-operation. or wall) in 1/4" (6 mm) increments-See Fig. 1 through Fig. 7 Note: The "A" dimension is based on a nominally gauged pipe thread "make-up"of .600" (15mm) per ANSI B2.1 [approxi- mately 71/2 threads]. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. Recycled (800)431-1588 Sales Offices Paper (800)8486051 Sales Fax Corporate Offices Revision lines indicate updated or new data. (914)829-2042 www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.09/19 P/N 9999970500 VIC O Worldwide Fire Protection Contacts www.tyco-fire.com Products Model BFV-N Butterfly Valve Grooved End General Technical Description Data . ,, The Model BFV-N Grooved End But- Approvals terfly Valves (Ref. Figure 1) are indi- UL and C-UL Listed cating type valves designed for use in FM Approved fire protection systems where a visual Listed by California State Fire Marshall indication is required as to whether the under Listing No.7770-1670:100 valve is open or closed.They are used, for example,as system,sectional, and All laboratory listings and approvals are for pump water control valves.They have indoor and outdoor use. cut groove inlet and outlet connections Sizes that are suitable for use with grooved 2-1/2 thru 10 Inch(DN65 thru DN250) end pipe couplings that are listed and approved for fire protection systems. Maximum Working Pressure 2-1/2 to 8 Inch(DN65 to DN200) For applications requiring supervision 300 psi(20,7)bar of the open position of the valve, the Gear Operators for the Model BFV-N 10 Inch(DN250) Butterfly Valves are provided with 175 psi(12,0 bar) two sets of factory installed inter- Materials of Construction nal switches each having SPDT con- Body tacts (Ref. Figure 3). The supervisory Ductile iron conforming to ASTM A395 switches transfer their electrical con- tacts when there is movement from the Body Coating valve's normal open position during the Polyamide first two revolutions of the handwheel. Disc Ductile iron conforming to ASTM A395 NOTICE The Model BFV-N Grooved End But- Disc Seal terfly Valves described herein must be conformingnde EPD t ASTM D2000 rubber to D2000 installed and maintained in compliance with this document,as well as with the Upper&Lower Stem applicable standards of the National Type 416 Stainless Steel conforming to Fire Protection Association,in addition ASTM 582 to the standards of any other authori- Lower Plug ties having jurisdiction. Failure to do so PVC may impair the performance of these devices. Operator Gear operator with iron housing The owner is responsible for main- taining their fire protection system and devices in proper operating con- , dition. Contact the installing contrac- tor or product manufacturer with any questions. Page 1 of 4 JULY 2015 TFP151O TFP1510 Page 2 of 4 Nominal Nominal Installation Dimensions Valve Pipe Inches(mm) Weight Sizes OD Lbs. Inches Inches (DN) (mm) A B C D E F G H (kg) (65) (73,0) (98,0) (303,3) (83,0) (144,0) (149,9) (147,8) (54,1) 0 (10,0) 76,1mm 3.00 3.85 11.94 3.25 5.67 5.90 5.82 2.13 0 22 (65) (76,1) (98,0) (303,3) (83,0) (144,0) (149,9) (147,8) (54,1) (10,0) (80) (88,9) (98,0) (317,0) (90,0) (150,9) (149,9) (148 8) (54,1) 0 (10,4) (100) (114,3) (116,0) (360,2) (110,0) (160,3) (149,9) (194,1) (54,1) 0 (12,7) . 5 5.56 5.86 15.17 4.84 7.32 5.90 7.64 2.13 0 31 (125) (141,3) (149,0) (385,3) (123,0) (185,9) (149,9) (194,1) (54,1) (14,1) 165,1mm — 5.86 17.54 5.93 8.62 5.90 7.64 2.13 0.67 41 (150) (165,1) (149,0) (445,5) (151,0) (218,9) (149,9) (194,1) (54,1) (17,0) (18,6) 6 6.63 5.86 17.54 5.93 8.62 5.90 7.64 2.13 0.67 41 (150) (168,3) (149,0) (445,5) (151,0) (218,9) (149,9) (194,1) (54,1) (17,0) (18,6) 8 8.63 5.26 19.42 6.87 9.80 9.80 7.91 2.13 5.86 53 (200) (219,1) (134,0) (493,3) (174,0) (248,9) (248,9) (200,9) (54,1) (148,8) (24,1) 10 10.75 6.29 24.03 9.17 11.61 18.00 9.49 3.03 7.41 88 (250) (273,1) (160,0) (610,4) (233,0) (294,9) (457,2) (241,0) (77,0) (188,2) (40,0) HANDWHEEL INDICATOR G r F FLAG 1/2"NPT / CONDUIT CONNECTION }}I GEAR — E zz �O= 4i OPERATOR BODY t ,�' 1 v B n D �� ��DISC i I A— FIGURE 1 MODEL BFV-N GROOVED END BUTTERFLY VALVE NOMINAL DIMENSIONS r " r I- SUPERVISORY I— AUXILIARY CONTACT RATING: SWITCH GND SWITCH 1/2A 0 125 VDC 1/4A @ 250 VDC SWITCH SHOWN SWITCH SHOWN 15.1A/12HP 125,250 VAC WITH VALVE _ ___ WITH VALVE 5A 0 125 VAC"L" `- --- -- -- --1 FULL OPEN `- --- - -' FULL OPEN o o Z W w cc O a, y > 0 O (9 5 * BELL END OF LINE PANEL RESISTOR POWER FIGURE 2 MODEL BFV-N BUTTERFLY VALVE INTERNAL SWITCH WIRING DIAGRAM WITH VALVE IN OPEN POSITION TFP1510 Page 3 of 4 FLOW RATE IN LITRES PER MINUTE(LPM) (1 GPM=3,785 LPM) 300 400 600 1000 2000 4000 6000 10000 20000 40000 5.0 1 1 1 1 1 I,1 1 I I I I 1 11 I t 4.0 0,30 01111 111IIIII�1IllllijIII3.0 ifl 1�1 0,20 ^ 20lP ',,!!i' iIIiiIIIII�I111 a x �� Icc m QzP'IiIIIIi!1IiIII1I1JiIIIIJiII1i1r III0,10 i� ,i�1il I i�� II�'I lii!' it Imill 1 li 1 I 0,06 ¢ ¢ 1.0 ...■■■._____. oh.. �L��■■���■ �o�..,'11■■■0 9!!!....o rum p I����llll .�. o0[ ii u• Cy imi .. ,/iioMEM p I 41 j, •EE= • 0 Q inn . 0 , • ,. n• .. I• .� MO CV ti m .��• 0,06 ;Le, rq 7 inn O n Z ■■ l: il.. ' "" •��• W V) mu• Z'An ■■O •m�Q. yuu ■�� O �:: C m■■ U ne . Jim uu `O iimm�i In Z.inu ■no. 0,05 $ a w 0.6 nnn!r 2 An=U J 0 : U., 0.A m o A n U Jnml__ mo■ o J an.g -- ' ,� ■_:_ _..-. 2 -- 2 _ ? _ - _„ __ = 0,04 W n z z 0.4 ti I' - i IlII ■■:1 11 ■ 0,03 QIII 0.3iI� I ��� I0,02 I I iI d1111111110.2I ► mII� 1 � 1 11 1II liIIIJ "j,'ii " 111111IIIIiiiiflllillliIIIIlII III 0,01 D 1 1I.�II IIII 11 IIII' IIIi1II1IIIIIIIIIIIIIII1II III 60 100 200 400 600 1000 2000 4000 6000 10000 15000 FLOW RATE IN GALLONS PER MINUTE(GPM) GRAPH A DN65 THROUGH DN250 MODEL BFV-N BUTTERFLY VALVE NOMINAL PRESSURE DROP VERSUS FLOW Installation NOTE: For outdoor applications with internal supervisory switches,it is rec- The , Model BFV-N Grooved End Butter- ommended that wiring connections fly Valves may be installed with flow in be made at a temperature above 15°F either direction and can be positioned (9°C),in order to insure sufficient flex- i�C, either horizontally or vertically. ibility of the wire lead insulation. 'rl C The grooved end pipe couplings used Stop A - O 70 with the Model BFV-N must be listed or OPEN approved for fire protection service and Adjustment e installed in accordance with the manu- facturers instructions. Procedure The Model BFV-N Butterfly Valve may SHUT be installed with any schedule of pres- The gear operator's OPEN and SHUT FIGURE 3 sure class of pipe or tubing that is listed position have been factory set. The MODEL BFV-N GROOVED END or approved for fire protection. following procedure should be used if BUTTERFLY VALVE As applicable, refer to Figure 2 for the slight adjustments are needed.Refer to OPERATOR ADJUSTMENT • internal switch wiring diagram. Figure 3. Step 1. Turn the Handwheel until the Step B. Close the valve by turning the Conduit and electrical connections valve is fully closed. Handwheel until the valve is fully in are to be made in accordance with the closed position. Ensure the disc the authority having jurisdiction and/ Step 2. Remove two lockscrews (A) has returned to the fully closed posi- or the National Electrical Code. With from the gear operator body. tion and the disc is centered in the seat reference to Figure 2, the supervisory Step 3. Turn the Shut Stop Screw (B) area. Readjust the Shut Stop Screw if switch is intended for connection to clockwise until snug. necessary. the supervisory circuit of a fire alarm Step7. Replace two lockscrews (A) control panel in accordance with NFPA Step 4. Turn the Handwheel until the into the he gear Operator body lockig 72.The auxiliary switch is intended for valve is fully open. the stops into position. the unsupervised connection to aux- Step 5.Turn the Open Stop Screw(C) iliary equipment in accordance with clockwise until snug. NFPA 70, National Electric Code. TFP151O Page 4 of 4 Care and Limited Ordering Maintenance Warranty Procedure Before closing a fire protection system For warranty terms and conditions,visit Grooved End Butterfly Valves control valve for maintenance or www.tyco-fire.com. Specify: (specify inch size) Model inspection work on either the valve or BFV-N Grooved End Butterfly Valve fire protection system which it con- with internal supervisory switches, trols, permission to shut down the P/N(specify): affected fire protection systems must 2-1/2 inch(DN65) 59-300-F-025N be obtained from the proper authorities 76,1mm(DN65)` 59-300-F-076N and all personnel who may be affected 3 inch(DN80) 59-300-F-030N by this decision must be notified. 4 inch(DN100) 59-300-F-040N 5 Inch(DN125) 59-300-F-050N The owner is responsible for the 165,1mm(DN150)' 59-300-F-165N inspection,testing,and maintenance of 6 inch(DN150) 59-300-F-060N their fire protection system and devices 8 inch(DN200) 59-300-F-O80N 10 inch(DN250) 59-300-F-100N In accordance with the applicable Stan-dards of the National Fire Protection 'Available for EM EA and APAC markets only Association(e.g.,NFPA 25),in addition to the standards of any authority having jurisdiction.Contact the installing con- tractor or product manufacturer with any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected,tested, and maintained by a qualified inspec- tion service. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale, PA 19446 I Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products,LP. All rights reserved. Vico Fire Protection Products Fire Sprinkler Pipe Schedule 10 and Schedule 40 Submittal Data Sheet FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATION:.. Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL C-UL and FM Listed. NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm in. mm In, mm lbs./ft. kg/m CRR• kNf Approvals and Specifications Both products meet or exceed IN 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 the following standards: 1% 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 • ASTM A135,Type E,Grade A(Schedule 10) 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 • ASTM A795,Type E,Grade A(Schedule 40) 2% 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 • NFPA 13 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected 4 4.500 114.3 4.260 0e.2 .120 3.05 5.62 8.37 6 19 to the toughest possible testing protocols to 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 ensure the highest quality and long-lasting performance. 6 6.625 168.3 6,357 161.5 .134 3.40 9.30 13.85 1010 8 8,625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Finishes and Coatings `Calculated using Standard(IL CRR formula,UL Fire Protection Directory,Category V/ZY All Wheatland black steel fire sprinkler pipe Up to 6"receives a proprietary mill coating to 'The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark(value of 7.0). ensure a clean,corrosion-resistant surface that outperforms and outlasts standard lacquer coatings.This coating allows the pipe to be SCHEDULE 40 SPECIFICATIONS easily painted,without special preparation. Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL black,or with hot-dip galvanizing,to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES FM/UL requirements for dry systems that meet in. mm In. mm in. mm tbs./ft. kg/m CRR' Lift the zinc coating specifications of ASTM A795 or A53,All Wheatland galvanized material is 1 1 3 5 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 also UL Listed. 1'/ 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 Product Marking 1i' '.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 Each length of Wheatland fire sprinkler pipe is continuously stenciled to show 2 2.375 60.3 2.067 52.5 54 3.91 3,66 5.45 1.00 30 the manufacturer,type of pipe,grade,size •Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. •The CRR Is a ratio value used to measure the ability of a pipe to withstand corrosion.and length.Barcoding is acceptable as a supplementary identification method. Threaded Schedule 40 steel pipe is used as the benchmark(value of 7.0). C t13 APPROVED SUBMITTAL INFORMATION PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: ❑ BLACK ❑ HOT-DIP GALVANIZED Wheatland Tube 700 South Dock Street Sharon,PA 16146 Wheatland Tube P 800,257.8182 F 724.346.7260 I infok5wheatland.com I wheatland.com ,N.CS1cELGROUP Ductile Iron Threaded Fittings :, ,...... .. . .._,...,,,,,,,,,,._,.„.,,, ._ . .. .„,-....,.... ...- .....„ - . . ,,-., „,,,,,,..::....:,,,,,,,,,,,,„,,, .,....„.„,..-. .„,....,,,.. . -.7,-1. ,,-,,--;'.0,„. ',,, -Iti.. re " t x 5� ,i. '' 'T „• r. ..�_.CJ§ ' d kF,Yj �41 ' ' i yi t �!? £fr 3WyykS ; r t •F `1. :41 ri ),.*:!'' . . .k:t H s . . k 5 4 P. i �Y 4 y�', +1 a t S ITH COOPER® INTERNATIONAL Ductile Iron Threaded Fittings Specifications s , .. . .. . • % branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C ® US • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 44> • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 %-. 1' '- 1 uch e ron i tings- ass I I c03us APPROVED LISTED Fig. 35E 3- 90°Elbow A Size A Packing Weight Part Number in in Inner Master lb __ � 1/2 3/4 1 35E3004 I-13 100 200 0.2 Ia 35E 3006 1.31 70 140 0.3 A 35E 3010 L50 40 80 0.5 III j■■i, 1-1/4 1-1 35E 3012 1.75 25 50 0.8 /2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E3074 2,70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow B Size Part Number A B Packing Weight F in in in Inner Master lb I -rikli 3/4 x 1/2 3511E3006004 1.20 1.72 80 160 0.3 -- 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RL3010006 1,38 1.45 50 100 0.4 EllWill �A 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 358E3012006 1,45 1.63 35 70 0-6 1-114 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0-6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 fiC.;; 7 x 1-1/2 35RE3020014 2,02 2.16 10 20 1.5 `a`' 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 '4 3yy i. 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size A Packing Weight Part Number it- r> in in Inner Master lb 1/2 35F 3004 0.88 150 300 0.2 4 /%lr + 3/4 35F 3006 0.98 80 160 0.3 K A 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 41)1�I� IA 1-1/2 351-3014 1.44 20 40 1_0 2 35F 3020 1.69 10 20 1.6 2-1/2 351 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size Part Number A Packing Weight . in in Inner Master lb mg w .01 - -I /7 35T 3004 1.13 80 160 0.3 IA 3/4 35T 3006 1.31 30 60 0.5 I_ 1 35T 3010 1-50 25 50 0.7 111111 1-1/4 35T3012 1.75 10 20 1.1 A I 1-1/2 35T3014 1.94 10 20 1,5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcuoper.com + ,i. I ucti e ron things- ass I I i c ® us APPROVED Fig. 35RT3-Reducing Tee LISTED " Size Part Number A B Packing Weight in in n n Inner Masser lb C 3/4 x 1/2 35913006004 1.20 1.20 122 60 120 0.4 x 1/2 35913010004 1.26 1.26 1.36 30 60 0.6 -� 1 x 1/2 x 1 35R13010004010 1.50 1.36 1.50 30 60 0-6 1x 3(4 35RT3010006 1.38 1.38 1.45 25 50 0.6 4 B 3 I l 1 x 3/4 x 3/4 35013010006006 1.38 1-31 1.45 35 70 0 6 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-114 x 1/2 35RT3012004 1 34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-114 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35813012006 1.45 1_45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1-58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35013012010006 1-45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x Ix 1-1/4 35R13012010012 1 75 1 69 1 75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 3518T3014004012 1.81 1,56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 351i13014006 1.52 1-52 175 16 32 1-1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1 94 1.66 1.88 20 40 1.1 1 1/2 x 3/4 x 1-1/2 35R13014006014 1.94 1 75 1_94 18 36 12 1-1/2x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x 1 x 1/2 358.13014010004 1.44 125 1.69 20 40 0,8 1-1/2 x 1 x 3/4 35RT3D14010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35913014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x(-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x 1 x 1-1/2 35RT3014010014 1-94 1-80 1.94- 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1,66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1 1/2 x 1-1/4 x 1 35R13014012010 1.65 1 58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x1-1/2 350T3014012014 1.94 1,88 1.94 14 28 1.4 2x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35913020006 1.60 1.60 1.9/ 10 20 1.6 2 x 1 35RT302001D 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 359T3020010020 225 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x 1-1/4x2 35913020012020 2.25 2.10 225 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 3513 13020014004 1.49 '.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 351313020014010 1.73 1 65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2x 1-1/2 358123020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size Part Number A B C Packing Weight J{MIn C n in in in Inner Master lb 3/4 x 1 35813006010 1 45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 �� ' x 1-1/2 35B13010014 1.80 1.80 1.65 15 30 1,0 " A B 1-1/4 x 1 x 1-1/2 358T3012010014 1.88 1.80 1.82 15 30 12 I-1/4 x 1-1/2 35BT3012014 1.88 1.88 1 82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35073014012020 2.16 210 202 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 Willi-COOPER INTERNATIONAL' • TOLL FREE 1 800-766-0076 • FAX(323)890-4456 • Dww.smithcooper.com 112 Ductile Iron Fittings-Class 300 UL/FM C (11) US APPROVED LISTED A Fig. 35CP3 -Straight Coupling with Ribs Sizein Part Number A Packing Weight in Inner Master ib h� I _ 1/2 35CP3004 81.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 22 Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packing Weight in in Inner Master lb 1 x 1/235R03010004 1.69 80 160 0.3 A 1 x 3,�4 35RC3010006 1.69 60 120 0.4 _ 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x 3/4 35H83010006 1.06 180 360 0.1 I�1 ^A 1-1/4x 1 35HB3012010 1.19 90 180 0.2 I 1 1-1/2 x 1 35HB3014010 1,25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x I-1/.4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35H133020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug ,..akSize part Number A Packing Weight in in inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 3/4 35S83006 1.12 350 700 0.1 I� ..A 1 35SP3010 1-25 200 400 0.1 1-1/4 355P3012 1.37 100 200 0.3 1-1/2 35SP3014 1 44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A r Size A Packing Weight pin in Part Number in Inner Master lb impak., 1111111111 35U 30102.1920401.0 1-1/435U 3012 2.50 15 30 1.2 1-1/2 35U 3014 7.62 10 20 1.7 „rgial 2 35U 3020 3.12 6 12 2.4 Us 113 SMITH-COOPER INTERNATIONAL•' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithuwper.com i. Ductile Iron Fittings- Class 300 UL/FM ( Q6arr sus c ® uS 400. APPROVED Fig. 35X 3— Cross LISTED A n. A Size A Packing Weight Part Number millin in n inner Master 40 lb _1111. �A 1 35X 3010 1 50 20 0.9 `' __ I I 1-1/4 35X3012 1.75 12 24 1.4 ^li I_� 11/2 35X 301x 1.94 8 16 1.8 ■•.re �A 2 35X 3020 225 6 12 2.8 B BFig. 35RX3—Reducing Cross _�'�' Size Part Number A B Packing Weight ._r_j'��'�.+. A In in in Inner Master lb 1 1-1/4 x 1 358X3012010 1.67 t_58 15 30 12 JJJ 1-1/2 x 1 35RX3014010 1-80 1.65 12 24 1.4 1__ I IA _ 2 x 1 350X3020010 2.02 1.73 8 16 2.0 III!-0'rei - " Fig.g Cap Size Part Number A Packing Weight in In Inner Master lb A 1/2 35C 3004 0-87 300 606 0 1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1 16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1 70 18 36 1.6 Fig. 35BC3—Beam Clamp Size Part Number A Packing Weight 4 in in Inner Master Ib 3/3 358C3003 0.75 100 200 0.3 112 35BC3004 0.75 80 160 0.5 S\trill-COUPE R TN;'1'F.I2NVTR)\,Al,'- • TO1.I, I-Rl?h: 1 800-766-0076 • FAN(3231890-44i) • 99R".smithcoopcccuul 114 Victaulic® FireLockTM Fittings ✓ctautic' 10.03 1041111*.. 1.0 PRODUCT DESCRIPTION Available Sizes • 11/4—8"/DN32— DN200 Maximum Working Pressure • Pressure ratings for Victaulic FireLockTm Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to ,7.24 for more information). Application • FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS ��o"� ® LPCBJ vas (E EN 10311 Regulation(EU) No.305/2011 3.0 SPECIFICATIONS- MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: Orange enamel. I Red enamel in Europe, Middle East, Africa, and India. Ij Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. •System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.03 1539 Rev N Updated 09/2017 02017 Victaulic Company.All rights reserved. ✓Ctaulno" 1 victaulic.com • 4.0 DIMENSIONS hCtoE 1 C j 1\ _4 j to a� 0 CtoE to e4 J✓l to -4),=1-,(4.- E br No.001 Nc.003 No.002 No.006 No.001 No.003 No.002 No.006 90°Elbow 45°Elbow Straight Tee Cap Actual Approximate Approximate Approximate Approximate Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg 11/4 1.660 - - - _ - - 0.82 0.3 DN32 42.4 - - - - - - 21 • 0.1 11/2 1.900 - - - - - 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2','2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 1.1 76 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 _. 1.8 64 1,4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6,7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3,0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 6.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6,94 38.7 1.13 12./ DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - -- • 10.03 1539 Rev N Updated 09/2017 02017 Victaulic Company.All rights reserved. v caulic.com 2 ✓ctaulrc victau!ic.com • 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Piper No.002 Actual Elbows Straight Tee Nominal Outside No.001 No.003 Size Diameter 90°Elbow 45°Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1 Y 1.660 - - - - DN32 42.4 - - - - 1K_. . 1.900. . DN40 48.3 - - 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1. . .. 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 _4.5._ 2.3.. . 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 _. _..3 3.500 5.0. .. 2.6 13.0 5.0 DN80 88.9 1.5 _... 0.8 4.0 1,5 _.._. 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 _.__. .4 4.500 6.8 _.. ._. 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN125 139.7 2.5 1.3 6.3 2.5 __.. 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 . .. 6 -.. 6.625 10.0 5.0. . 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 6.500 _. 9.8_. . .. 4.9 24.5 I. 9.8 165.1 3.0 1.5 7.5 3.0 _.. 8 8.625 13.0 _.. 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 _.. 4.0 8.515 13.0 - 33.0 13.0 2163 4.0 - _._. 10.1.. ._. . 4.0 _...... : r The flow data listed is based upon the pressure drop of Schedule 40 pipe. • 10.03 1539 Rev N Updated 09/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulrc' victaulic.com • 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZTM couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTm Style 009N/009H couplings, use FireLockTM No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products far a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring ob'gations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disc,aimec of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights •n PDF format on our website at www.victaulic.com. Nc statement Contained herein concerning a possible or suggested use of any material, Warn nty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patentor other intel ectual property right at Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries, or patent applications for articles and/or methods of use in the United States and/or other countries. • 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctauhc' 1 • : cow FM vas LPCB 0, r ;� x , a�r<^ 104-1a/05 1. 3,q"4,� -.. ` =' [f l t[Ei�. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 750 The Style 750 Reducing Coupling permits direct reduction on the piping run. Designed to replace two couplings and a reducing fitting,the Style 750 features a special reducing1111 oil._ gasket for pressure responsive sealing.A steel washer which prevents telescoping of the smaller pipe inside the larger pipe during vertical systems assembly is available upon request. 1ll 1�11 ro MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating:Orange enamel • Optional: Hot dipped galvanized and others Gasket:(Specify choice*): • Grade"E"EPDM(All other sizes) EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. IJL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C potable water service.NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range.Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. * Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional:Assembly Washer:Galvanized,carbon steel Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. • JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com Jctaulro' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV 06.08 STYLE 750 DIMENSIONS Max.Work Allow.Pipe Bolt/Nut@ Size Pressure* Max.End Load" End Sep.1 Deflect.Fr,C t No- ni.Each c. i Size Dimensions-Inches/mm Wg1.E ace-.-a.-., i .. b ,s 2 1 350 500 0 0.07 0.20 3.38 5.28 1.88 2.7 50 25 2410 2225 0-1.8 0'-5T 17 2-3/822 85 134 48 1.2 1% 350 1000 0-0.07 0.20 3.38 5.28 1.88 2.0 40 2410 4450 0-1.8 0°-57' 17 2-3/8x2 85 134 48 10 2'h 2 500 2215 0-0,07 0.16 4.00 5.93 1.88 3.1 65 x 50 3450 9850 0-1.8 0°-4T 14 2-3/8x2 102 151 48 14 76.1 mm x 2 350 1550 0-0.07 0.16 4.38 6.63 1.88 4.6 50 2410 6900 0-1.8 0`-4T 14 2-'hx2sk 111 168 48 2.1 3 2 350 1550 0-0.07 0.'3 4.75 7,13 1.88 4.9 80 x 50 2410 6900 0-1.8 0°-39' 11 2-'hx234 121 181 48 2.2 21/2 500 3250 0-0.07 0°-39, 0.13 4.75 7.13 1.88 43 65 3450 14460 0-1.8 n 2-Yzx23H 121 181 48 2.0 350 2475 0-0.07 0.13 4.75 7.13 1.88 4.2 889mm x 76.1mm 2410 11010 0-1.8 0°-39' 11 2-'hx 2'/ 721 181 48 1.9 4 2 350 1550 0-0.13 0.28 6.25 8.90 2.25 8.1 100 x 50 2410 6900 0-3.2 1°-19' 25 2-5/8 x 3 m 159 226 57 3.7 2Vz 350 2275 0-0.13 1° 19, 0.28 2-5/Bx3'/. 6.25 8.90 2.25 8.6 65 2410 10125 0-3.2 25 159 226 57 3.9 3 500 4810 0-0.13 0.28 6.00 8.90 2.25 6.7 80 3450 21400 0-3.2 1 -19 25 2-5/8 x 3 V. 152 226 57 3.0 ' 114.3mm x 76.1mm 350 2475 0-0.13 0.28 6.25 8.90 2.25 6.9 2410 11014 0-3.2 1"-19 25 2-5/8231/4 159 226 57 3.1 5 4 350 5565 0-0.13 1°_3, 0.22 2-V.x4'V 7.18 10.70 2.13 11.2 125 100 2410 24765 0-3.2 19 x 182 272 54 5.1 6 4 350 5565 0-0.13 0°-52' 0.18 2-Y4x4%< x 8.63 11.90 2.25 16.7 150 100 2410 24765 0-3.2 15 181 302 57 76 5 350 8500 0-0.13 0.18 8.31 11.90 2.25 12.9 125 2410 37825 0-3.2 0 -52 15 2-84x4'/a 211 302 57 5.9 165.1mm x 4 350 5565 0-0.13 0.19 8,63 11.90 2.25 15.2 100 2410 24765 0-3.2 0°-55' 16 2-8.243/4 219 302 57 6.9 8 6 350 12060 0-013 0.13 1081 '4.88 2.50 22.4 200 x 150 2410 53645 0-3.2 0'-38' 11 2-7/8 x 5 275 378 64 10.2 219.1mm x 165.1mm 350 11610 0-0.13 0.13 10.75 14.88 2.50 23.2 2410 51645 0-3.2 0 -38 71 2-7/8 x 5 273 378 64 10.5 10 8 350 20450 0-0.13 0.9 13,12 17.26 2.62 31.4 273 x 219.1 2410 90970 0-3.2 0°-25' 8 2-1 x 51/2 333 438 67 14.2 Style 750 Reducing couplings should not be used with end caps 0460)in systems where a vacuum may be developed.Contact Victaulic for details. Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.Maximum working pressure rating based on larger pipe size. Maximum End Load rating based on smaller pipe size.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 3/4-31/2720-90 mm;25%for 47100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. ^Y �Z v . Z-. S .:r1 .liL',QRD,III ;r.r/ - .r.r, 1rTT1 II II • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ,Ctal.11 I C (lb 08 2 CARBON STEEL PIPE-GROOVED COUPLINGS 06.08 Red Li fj % n CI STYLE 750 .. ......_.. . ...._...... ............. . . FLOW DATA HEAD LOSS The head loss across Style 750 Reducing coupling is very small and is essentially the same as for standard short body reducing pipe fittings. Equivalent lengths of standard weight steel pipe are shown in the tables.All data is based on water flowing at ambient temperature. FLOW REDUCING FLOW EXPANDING iEp 2 59 2 27 50 25 1.8 23 x 50 0 8 1' 2.0 11/2 2 19 40 0.6 40 x 50 0.6 2Y2 2 19 2 21 1.0 65 x 50 0.6 50 x 65 0.3 76.1mm x0.3 50 0.66 2 1.976.1 mm 1.0 3 2 5.5 3 35 80 x 50 1.7 80 1.1 2%a 3.8 4 30 65 1.2 100 0.9 88.9mm x 76.1mm 38 217: 3 25 1.2 65 x 80 0.8 4 2 6.0 4 3.0 100 x 50 1.8 100 09 216 6.0 2.5 76.1 mm x 88.9mm 65 1.8 0.8 3 60 3.0 1143mm 80 1,8 0.9 1143mm x 76.1mm 6.0 3 4 2.5 1.0 3ao x 100 08 5 4 30 4 5 3.3 125 x 100 0.9 100 x 125 1.0 6 4 6.0 6 4.6 150 x 100 1.8 150 1.4 5 4.5 165.1 mm 4.6 125 14 1.4 165.Imm x 4 6.0 5 6 2 3 100 1 8 125 x 150 0.7 8 6 7.3 6 8 60 200 x 150 2 2 150 x 200 1 8 73 165.1mm x 219.1mm 5.4 219.1 mm x 165.1 mm 2 23 1.65 10 8 8.7 8 10 6.3 273 x 219.1 2.65 219.1 x 273 19.2 • . ...__.... www.victaulic.com NjCt9Ul1C` VIC-AUL C IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 02012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. CARRON 5T PIPE 0300y x�. Op41NG$ Q6, Q `rain.t. -V-ifi+^?'9ZNS'k�`f` har,a '. 4k „ STYLE 750 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 06.08 1536 REV 1 UPDATED 08/2012 Ic�traUlac VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY©2012 VICTAULIC COMPANY ALL RIGHTS RESERVED _- ,,,.._,.__._....-. 06 08 Victaulic® FirelockTM Rigid Coupling ✓ctaul,c' Style 009N 10.64 Patented 1.0 CERTIFICATION/LISTINGS On rM ILPCBJ (vds) C104-1a/36 2.0 PRODUCT DESCRIPTION • The FireLock EZTm Style 009N Installation-ReadyTM Rigid Coupling is for use in the fire protection market. • The coupling's unique design eliminates loose parts, promotes consistent installation and provides substantial gains in productivity. • IMPORTANT: FireLock EZTM Style 009N couplings are recommended for use ONLY on fire protection systems. 3.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Orange enamel (North America, Asia Pacific) Red enamel (Europe) Hot dipped galvanized Gasket: (specify choice') Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry(oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest .. for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. •System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev G Updated 10/2014 ®2014 Victaulic Company.All rights reserved.1 �Ctaul.c victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 4.0 LISTINGS/APPROVAL 2 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. .............................. Nominal Size cULus FM Vds LPCB Sch.5 Sch. 10 Sch.40 Sch.5 Sch. 10 Sch.40 inches psi psi psi psi psi psi psi psi mm kPa kPa kPa kPa kPa kPa kPa kPa 1 Ya 232 365 365 175 363 363 363 363 32 1600 2517 2517 1205 2502 2502 2500 2500 11/2 232 365 365 175 363 363 363 363 40 1600 2517 2517 1205 2502 2502 , 2500 2500 2 363 365 365 175 363 363 363 363 50 2502 2517 -.., 2517 1205 2502 2502 2500 2500 21/2 N/A 365 365 175 363 363 363 363 65 2517 2517 1205 2502 2502 2500 2500 .. -_ ; _._ _.. 3634 363 ;.... 363 _.. 76.1 mm N/A 2517' N/A N/A 25024 N/A 2500 2500 3 N/A 365 365 175 363 363 363 363 80 2517 2517 1205 2502 2502 2500 2500 4 N/A 365 365 175 363 363 363 363 100 2517 2517 1205 2502 2502 2500 2500 108.0mm N/A N/A N/A 175 363 363 N/A N/A _.. 1205 2502 2502 5 290 365 363 363 232 N/A 125 N/A ...., . 2000 2517 N/A 2502 2502 1600 Q 133.Omm N/A N/A N/A N/A 2502° N/A N/A N/A 139.7 mm N/A ....__2000290 55 N/A N/A 2502•° N/A 1 363 4 260D N/A 159.0mm N/A N/A N/A N/A 2502363 4° N/A N/A N/A _. . 2906 _. __.. 363" 165.1 mm N/A 2000 6 N/A N/A 2502^ N/A N/A N/A '.. 6 N/A 290 365..... N/A ..._. 363._.. 363._.. 232 -..... N/A 150 2000 2517 2502 2502 1600 363 a 216.0 mm N/A N/A N/A N/A 2502° N/A N/A N/A 8 290 365 363 363 232 - N/A 200 N/A 2000 2517 WA 2502 2502 1600 2 Listed/Approved for wet and dry pipe systems(>-40°F/-40°Cl for continuous use in freezing conditions,use of Style 005H Coupling with Silicone Gasket is recommended. Please see the Victaulic - trrhr l.J'._H for details concerning when supplemental lubrication is required. 3 cULus listed for DIN 2458 2.6 mm pipe wall. 4 FM approved for BS 1387 Medium 3.6 min pipe wall. 5 cULus listed for EN 10220 4.0 mm pipe wall. 6 cULus listed for EN 10255 4.5 mm pipe wall. • 10.64 7072 Rev G Updated 10/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulrc' victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 4.1 LISTINGS/APPROVAL Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size Pressure Rating cULus FM cULus FM cULus FM inches psi psi inches psi psi inches psi psi kPa kPa kPa kPa -.. kPa kPa 300 365 , 300 365 MT 1 Ya-2 300 365 BLT 1'/a-2 2068 2517 EZT 1 /a 2 2068 2517 2068 2517 300 365-_.. - _. 300 365 MLT 1Y.-2 N/A 365 DF 1'/a-4 2068 2 17 FF 1Ys 4 2068 2517 2517 ._. . . ..300 365 365 365 DT 1 Va-2 2068 2517 FLF 1'4-4 N/A 2517 ST 1 Ya-2 N/A 2517 EF 1/-4 11Z06 1175 06... . FLT 1'A-2 N/A 2567 STF 1'/a-4 N/A 365 2517_,. 300 365 FLTL 1 V.-2 N/A 365 TF 2'A-4 WA 365 • EL 1 Ya-2 2068 2517 2517 ,_.. 2517 300 365 , 300 365 yV� 1,/a_2 3D0 365 ET40 1'/a-2 2068 2517 GL 1/a-2 2068 2517 2068. 2517 300 365 MF 1'/a-4 300 365 WST 1 Va-2 N/A 365 EZF 3-4 2068 2517 2068 2517. ,. _- . 2517_.. _. . _. - .. -..... . .. - - XL 1/a-2 300 365 2068.. .. 2517 NOTES • BLT=BLT steel pipe manufactured by Allied Tube&Conduit Corp. • DF=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • DT=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • ELF=Fire-Line Flow steel pipe manufactured by Western International Forest Products Inc. • FLT=Fire-Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL=Fire-Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL=GL steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ST=STD wall pipe in accordance with ASTM A53. • STF=Steady Flow steel pipe manufactured by AMS Tube Corp. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • WST=WST steel pipe manufactured by Wheatland Tube Company. • XL=XL steel pipe manufactured by Allied Tube&Conduit Corp. • 1 10.64 7072 Rev G Updated 10/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 3 Jotauhc- victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 5.0 DIMENSIONS Style 009N -y :.�\ .i �71 ;:*1iI ��� ��i ij Style 009N Pre-Assembled Style 009N Joint Assembled (Push On Condition) Dimensions• Actual Maximum Maximum Allow. Pre-assembled Approx. Nominal Outside Working End Pipe End Bolt/Nut a (Push On Condition) Joint Assembled Weight Size Diameter Pressure 7 Load 7 Separation° Size X Y X Y Z Each inches inches psi lbs. inches inches inches inches inches inches inches lbs. mm mm kPa N mm No. mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 le 2 3.13 5.00 2.75 5.00 2.00 1.4 32 42.4 2517 3514 2.54 2 M10x2 79 127 70 127 51 0.6 11/2 1.900 365 1035 0.10 2 3/e x 2 3.38 5.13 3.00 5.13 2.00 1.5 40 48.3 2517 4604 2.54 M 10 x 2 86 130 76 130 51 0.7 2 2.375 365 1616 0.12 3/4x2'/ 4.00 5.63 3.50 5.63 2.00 1.9 50 60.3 2517 7193 3.05 2 M10x21/2 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.12 3 x 21/2 4.50 6.13 4.00 6.13 2.00 2.1 65 73.0 2517 10542 3.05 2 M 10 x 2 1/2 114 156 102 156 51 1.0 76.1mm 3.000 365 2580 0.72 2 Mx 21/2 4.63 6.00 4.13 6.13 2.00 2.1 76.1 2517 11476 3.05 M10 x 21/2 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 3/8 x 2 Y2 5.13 6.75 4.63 6.75 2.00 2.3 80 88.9 2517 15622 3.05 2 M 10 x 2 Yx 130 171 117 171 51 1.0 1 4 4.500 365 5805 0.17 Ye x 2'1 6.00 7.88 5.63 7.50 2.13 2.9 1 _100 114.3 2517 25822 4.32 2 M10x21/2 152 200 143 191 54 1.3 lOB.Omm 4.250 365 5175 0.17 Me x2'h 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 2 M10x21/2 152 1.87 137 187 54 1.4 5 5.563 365 8870 0.17 1 x 3 7.25 9.25 6.75 9.13 2.25 5.0 125 141.3 2000 39456 4.32 2 M12 x 3 184 235 171 232 57 2.3 133.0 mm 5.250 365 7897 0.17 1 x 3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 - 4.32 2 : M12 x 3 168 229 162 229 57 2.2 139.7 mm 5.500 365 8667 0.17 Y x 3 6.88 9.25 6.75 9.13 2.25 4.9 139.7 2517 38529 4.32 2 M 12 x 3 175 235 171 232 57 2.2 159.0 mm 6.250 365 11192 0.17 ' x 3 Ya 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 2 M12 x 3 V. 200 254 187 - 251 57 2.5 165.1 mm 6.500 365 12105 0.17 1/2x 3'/. 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 2 M12 x 3 V. 203 260 197 257 57 2.7 6 6.625 365 12582 0.17 Y:x 3'/a 8.38 10.38 7.88 10.13 2.25 6.0 150 168.3 2000 44469 4.32 2 M12 x 3'/4 213 264 200 257 57 2.7 216.0 mm 8.500 365 20712 0.17 3/41x4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 2 M16 x 4 270 337 260 257 67 5.2 8 8.625 365 21326 0.17 Ye x 4 10.88 13.38 10.25 13.13 2.50 --- 11.4 200 219.1 1620 94863 4.32 2 M16 x 4 276 340 260 333 64 5.2 7 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll ur cut grooved in accordance with Victaulic specifications,See the Listings/Approvals section of this publication for ratings on other pipe. 8 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZTM couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 9 Number of bolts required equals number of housing segments. NOTES • When assembling FireLock EZt"couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZT"Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZ'"couplings are supplied with FireLock EZ'"Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic Flush-Seal'"gaskets are not compatible and cannot be used with the FireLock EZ'"couplings. • • 10.64 7072 Rev G Updated 10/2014 m 2014 Victaulic Company.All rights reserved. victaulic.com 4 rctaul•c' victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • 6.0 REFERENCE MATERIALS Seal Selection Guide Installation Instructions FireLock EZTM Rigid Coupling • User Responsibility for Product Selection and Suitability Note Each user bears final respons•bility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications_Pill products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications.as well as Victaulic performance,maintenance, Victaulic reserves the right to change product specifications,designs and standard safety,and warning instructions.Nothing in this or any other document,nor any verbal equipment without notice and without incurring obligations. recommendation,advice,or opinion from any Victaulic employee,shall be deemed to Installation alter,vary,supersede,or waive any provision of Victaulic Company's standard conditions Reference should always be made to the I ' ` -yjj, ,c of sale,installation guide,or this disclaimer. r for the product you are installing Handbooks are included with Intellectual Property Rights each shipment of Victaulic products,providing complete installation and assembly data, No statement contained herein concerning a possible or suggested use of any material, and are available in PDF format on our website at www viclau.ic.com_ product,service,or design is intended,or should be constructed,to grant any license warranty under any patentor other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details. or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patentor other intellectual yleariq Firelock EZTM,Flush.SealTM,and Installation-Ready'.are trademarks or property right.The terms"Patented"or"Patent Pending"refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other registered trademarks of Victaulic Company,and/or its affiliated entities,in the U.S,and/ countries. or other countries. • e 10.64 7072 Rev G Updated 10/2014 ei 2014 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaultc' c FM VdS ILPCB S; S 3 LIS1III 491a27 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 • The Style 922 Outlet-T provides a convenient method of incorporating l/,3/4,and 1"/15,20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/4 through 76.1 mm/32 to 76.1mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS *41 Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly • compresses the gasket onto the 0D of the pipe.The Style 922 outlet-T is UUFM rated up to 300psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. 'Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. • Gasket: • • Grade"E"EPDM -Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com �Ct9uI.C' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 02009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV S 10.52 STYLE 922 DIMENSIONS Nominal Size Hole Approx. inches/mos Diameter Dimensions-inches/millimeters Weight Each .. v` F Y r-2� 1Ya x v, 3/I5 1.30 -.83 65 110 3.87 2.56 1.0 V 32 15 3/12 1.28 a65 1.10 3.87 250 OAS I 8. 13/16 1.28 1.83 1.10 3.87 2.56 1.1 I20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 T --_-- W hr� 1 13/16 152 2.18 '.'0 3.87 2.56 1.2 1VI 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11 A Vs13/16 1.42 1.95 1.22 4.08 2.56 1-2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 44 13/16 140 1.95 1.22 4.08 2,56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 584 31.0 103.6 65.0 0.59 2 X 1/2 1 3/16 1.66 2.19 146 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65,0 0.59 p 13/16 1.64 2.19 146 4.60 2.56 1.4 20 30.2 417 55.6 37.1 116,8 65.0 0.64 1 13/15 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21 X 1/2 1 3/16 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 14.._-. 13/16 189 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 434 137.2 65.0 0.73 .__..1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 tom X 1/21 3/16 1.91 2.44 1.71 5,50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3.'_._. 1 3/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 ....1... 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30,2 54.1 70.9 43.4 139,7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. "Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com Nict9 u l L c' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.52 2 10.52 STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size z Outlet Size 213,Section 16)(C_120)*,FT 1V 1 8.5 32 25 2.6 1' ... X .'_. 8.5 40 25. 2.6 2 X 1 8.5 50 25 2.6 21 X 1 8.5 65 25 2.6 76.1 minX i 8.5 25 2.6 "Hazen-Williams coefficient of friction is 120 www.victaulic.com \C to u I i C VICTAUL IC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2009 VICTAOLIC COMPANY ALL RIGHTS RESERVED. r2Ev STYLE 922 INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www victaulic.com 10.52 3355 REYG UPDATED 12/2009 ,ctauIic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY,ALL RIGHTS RESERVED. 10.52 Victaulic° Flexible Coupling /4taulrcJ Style 75 Vr 06.05 WARNING cat • Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. �ru Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or Exaggerated for clarity property damage. Approvals/Listings ® C'" LPCB ® Q (yds) NOTICE See Victaulic for details • Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and See Victaulic for portable water approvals if applicahle. the designation RX on the front of the roll sets. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes,the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference p or9 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to 17.U1. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 updated 09/2014 ®2014 Victaulic Company.All rights reserved. 1 ✓otauLC victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Material Specifications Housing: Bolts/Nuts: Ductile iron conforming to ASTM A-536, grade 65-45-12. Heat-treated plated carbon steel,trackhead meeting the Ductile iron conforming to ASTM A-395, grade 65-45-15, physical and chemical requirements of ASTM A-449 and is available upon special request. physical requirements of ASTM A-183 Housing Coating: (specify choice) Standard: Orange enamel. Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE:Additional gasket styles are available,Contact Victaulic for details. Grade"E"EPDM EPDM (Green stripe color code). Temperature range—30°F to+230°F/-34°C to+110°C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. Grade"T" Nitrile Nitrile (Orange stripe color code). Temperature range 20°F to +180°F/29°C to+82°C. May be specified for petroleum products, air with oil vapors,vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150°F/+66°C or for hot dry air over+140°F/+60°C. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest for specific gasket service guidelines and'or a listing of se'vices which are not compatible. 06.05 1470 Rev 0 Updated 09/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 2 rctaulrc' victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Dimensions Style 75 Y �21 r.r r.r I r:r l i1li till Actual Maximum Maximum Allow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure' Load z Separation' Centerline' Balt/Nute X Y Z Each Pipe inches inches psi lbs. inches Per Cplg. inches/ft. inches inches inches lbs. mrn mm kPa N mm Degrees mm/m (No.)size inches mm mm mm kg 1 1.315 500 680 0-0.06 2° 43, 0.57 2-'/°x2 2.38 4.27 1.77 1.3 25. 33.4. 3450 3025 0 1.6 48 61 108 45 0.6 1 1 1.660 500 1080 0-0.06 ° 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2-10 38 2-fie x 2 68 117 45 0.6 1 Vs 1.900 500 1420 0-0.06 1°-56, 0.40 2-3/4 x 2 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 33 74 122 45 0.6 2 2.375 500 2215 0-0.06 1°-31' 0.32 2-3/4 x2 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 26 87 133 48 0.8 2 Ys 2.875 500. 3245 0-0.06 ° 0.26 a 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 1 15 22 2-/s x 2 98 144 48 0.9 76.1 mm 3.000 500 3535 0-0.06 1° 12 2-1'ex2 0.26 4.00 5.90 1.88 1.9 76.1 3450 15730 0-1.6 22 102 150 48 0.9 3 3.500 500 4800 0-0.06 : 10 2, 0.22 2-%zx2'a 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 18 114 178 48 1.3 3 Y 4.000 500 6300 0-0.06 : 0.19 5.00 7.50 1.88 2.9 0°-54' 2-'h x 2'a 90 101.6 3450 28035 0-1.6 16 127 191 48 1.3 4 4.500 500 7950 0-0.13 1°-36' 0.34 2-'/z x 2'/. 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 28 147 204 54 1.9 108.0 mm 4.250 450 6380 0-0.13 1°-41, 0.35 2-12 x 70 5.55 7.79 2.13 3.7 108.0 3100 28395 0-3.2 29 141 198 54 1.7 4Yz 5.000 450 8820 0-0.13 0.25 ... 6.13 9.43 2.13 5.5 1°-26' 120 2-%x3Ya 127.0 3100 39250 0-3.2 21 156 240 54 2.5 5 5.563 450 10935 0-0.13 1° 18' 0.27 2-34x 3'/a 6.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 23 175 256 54 2.6 5.250 450 9735 0-0.13 0.28 6.55 9.37 2.13 6.0 1330mm 1°-21' 2-16x82.5 1330 3100 43325 0-3.2 24 166 238 54 2.7 5.500 450 10665 0-0.13 0.28 139.7 mm 1°-18' 2-s/ex3'/a 6.80 9.59 2.13 6.3 139.7 3100 ! 47460. 0-3.2 24 173 244 54 2.9 152.4 mm 6.000 450 12735 0-0.13 1°-12, 0.21 2-'/e x 3'/a 7.38 10.48 1.88 6.2 152.4 3100 56670 0-3.2 18 187 266 . 48 2.8 6 6.625 450 15525 0-0.13 1,-5 0.23 2-%x3'a 8.00 11.07 2.13 7.0 150 168.3 3100 69085 0-3.2 18 203 281 54 3.2 159.0 mm 6.250 450 13800 0-0.13 1°-9, 0.24 2_16 x 82.5 7.63 10.49 2.13 6.8 159.0 3100 61405 ,._ 0 3.2 20 194 266 54 3.1 8 8.625 450 26280 0-0.13 00 50' 0.19 2-'ax4'a 10.34 13.97 2.13. 12.4 200 219.1 3100 116945 0-3.2 14 263 355 59 5.6 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulm specifications.Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums:for design and installation purposes these figures should be reduced by: 50%for'/a-3 1/2"/20-90 mm,25%for 47100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:FOR ONE TIME FIELD TEST GNI Y,the Maximum Joint Working Pressure may he increased to 11/2 times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctau6c' victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Installation Note Reference should always be made to the f- for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each sh,pment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assemb.y data,and are available in POF format Victaulir reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details- Victaulic°is a registered trademark of Victaulic Company. 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 Ictau6c' Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ®TOLCD Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) l: DL us Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut tlsrlo Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications s Function: For fire sprinkler and othergeneral pipingr P purposes. Knurled swivel nut design permits hanger adjustment after installation. A Features: • • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design ,r' " i keeps adjusting nut from separating with hanger. Hanger is easily a B installed around pipe. For hanger with non-captured nut order Fig. 200S. ' n • (21/2" 165mm)thru 8" (200mml) Spring tension on nut holds it securely in �� hanger before installation.Adjusting nut is easily removed. 5 Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) = i Fig egg,/:200-3/a in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (200mm)). Fig.2801 to 200•2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications VVW-H-171 E &A-A-1 192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 &SP-58, Type 10. Maximum Temperature: 650°F (343°C) w ' Finish: Pre-Galvanized. Stainless Steel r s, materials will be supplied with (2) hex nuts T in place of a knurl nut. I., Order By: Figure number and pipe size '<.;_ Designed to meet or exceed requirements of g FM DS 2-0. 1 a c. Fig.200 S r Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 +.. Part No. in. 1mm) in. (mml in. (mm) lbs. (kg) `"roYI" 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.71 11 15.0) 200-3/4 3/4" 120) 1/8'-16 31/8" (79.4) 21/2" (63.51 11 (5.0) 200-1 1" (25) 3/8"-16 33/a" (85.71 25/8" (66.7) 12 15.51 200-11/4 11/4" (32) 3/8'"-16 33/4" (94.0) 27/8" 173.0) 13 (5.91 200-11/2 11/2" (40) 3/8"-16 37/6" 198.4) 27/6" (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.31 3" 176.3) 15 16.9) 200-21/2 21/2" (65) 3/t"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) - 200-3 3" 1751 3/8"-16 57/8" (149.11 4" (101.6) 29 113.31 Fig.200S 200-31/2 31/2" 190( 3/8'-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8" 16 73/8" 1187.31 5' (127.01 35 (16.0) 200-5 5" (125) 1/2"•13 91/8° (231.8) 61/4" (158.7) 66 (30.21 200-6 6" (1501 1/2'-13 101/8" 1257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2%13 131/8" (333.4) 83/4" 1222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in mil6melers unless otherwise specified. p a Fire Protection Solutions 21 u-Line by MIA Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) 63205E - Threaded Rod (right & left hand threads) n Specify Length Size Range: 3/8"-16 thru 3"-4 rod L'� Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. rL '1) Rod is threaded on both ends with right hand threads of the length shown.Also �1\ A available with left and right hand threads-specify Fig. B3205L when ordering. �' \- Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. - Order By: Part number,rod size, length and finish Standard Desig■Load Thread Size Thread Length TL 650°F(343'C) 750°F(399°C) Part No. A in, (mm) Lbs. (kN) Lbs. (kN) 133205-3/8x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2x'1' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B32O5-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 113205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'1' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/e x'1.' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'1' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'1' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 133205-21/4x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'1' 21/2%4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'12 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'1' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) �� Fig. 99 - All Threaded Rod Cut To Length . Size Range: 3/8" 16 thru 11/2" 6 rod in 120"(3.05m)lengths or cut to length 00 r -" fro Material: Steel N iii 000' - ad Maximum Temperature: 750°F(399°C) Ixo Finish: Plain. Contact B-Line for alternative finishes and materials. ` _ ix" Order By: Part number, rod diameter and finish 1....a Part No.- 'ze x Length Threads Recommended Load Approx.Wt./100 Ft. - ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATRIA"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/e"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 8/e"x 120 99-8/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 7/8"x 120 99-7/e"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B_L■ 'ne Revised 4/28/2014 Pipe Hangers&Supports 236 by Ea•N VERTICAL MOUNT SAMMYS® SAMMYS° for Steel Installs VERTICALLY into the bottom of steel structures easily and quickly! • _' n� � •Made with Teks®self-drilling fasteners ' 'I requjred no pre-drilling required. x' •Install into steel range from 22 gauge—1/2"thicknesses • - j}j}j •Saves time from traditional methods. A[IE VW •Reduces installation cost. r t'K;. 6 0 •Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. ' 1/4" 8024957 DSTR 100' 114-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 114' 8025957 DST 100 1/4-14 x 1"TEKS 3 446 (20 ga.) .036'-20 ga 3116" 25 125 1/4' 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970(16 ga.) .036.20 ga 3/16' 25 125 1l4" 8027957 DST 200 114-14 x 2"TEKS 3 446(20 ga.) .036°-20 ga 3/16' 25 125 1/4" 8030957 TEK 500 12-24 x 1-12'TEKS 5 3125(3/16') .187°-3/16° 1/2' 25 125 IN.0 3B" 8038957 DSTR 1* 1/4-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 ® 3/6" 8037957 DSTR 1-12' 12-24 x 1-1/2'TEKS 5 1510(3/16') 1500 1475 .060'-16 ga. 12' 25 125 f ,Q 3/8" 8039957 DSTR 516* 5/16-18 x 1-1/4"TEKS 3 2200(20 ga.) 1500 1475 .036"-20 ga 1/8" 25 125 3/6• 8040957 DST 10 1/4-14 x 1'TEKS 3 446(20 ga') .036%20 ga 3/16" 25 125 814 Black 970 (16 ga.) Nut Driver ( g Part#8113910 3/8' 8077925 DST 10-SS 114-14 x 1'TEKS 3 446 20 a.) .036"-20 ga 3116" 25 125 970 (16 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-12'TEKS 3 446(20 ga.) .036'-20 ga 3/16" 25 125 970(16 ga.) 3/8'' 8078925 DST 15-SS 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20ga 3/16' 25 125 970 (16 ga.) 3/8' 8042957 DST 20 1/4-14 x 2 TEKS'3 446(20 ga.) .036"-20 ga 3/16" 25 125 970(16 ga.) 3/8" 8043957 DST 25 1/4-14 x 2-12"TEKS 3 446 (20 ga) .036"-20 ga 3(16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 114-14 x 3"TEKS 3 446(20 9a') 036"-20 ga 3/16" 25 125 n 970(16ga.) ^�^Q 3/8" 8045957 DST 516 5/16-18 x 1-114"TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 1/8" 25 125 di,Q 3/8' 8046957 TEK 50 12-24 x 1-12•TEKS 5 3125(3/161 1500 1475 .187°-3/16" 1/2' 25 125 _ I/O' 8031925 DST2.0 1/4-14 x 2"TEKS 3 446(20 ga.) .188"-3/16" 1(4" 25 125 970(16 ga.) 1/2' 8033925 DSTR 1.0' 1/4-20 x 1"TEKS 3 1510(20 ga.) .036•-20 ga 3/16' 25 125 12" 8034925 DSTR 5.16' 5/16-18 x 1-114"TEKS 3 2220 (20 ga.) .036"-20 ga 1/8' 25 125 1/2' 8035925. 0815,16 5/16-18x1-1/4'1EK83 1500(3/16") .125'-116' 1/8' 25 125 1/2' 8036925 TEK 5.0 12-24 x 1-112'TEKS 5 3125 (3116") .187"-3/16' 1/2' 25 125 #14 SW Red — *Includes retaining nut Nut Driver Part#8114910 SAMMY Swivel Head® for Steel Installs VERTICALLY and swivels up to 17° in steel structure Eliminates distortion of threaded rod in •Installs into angled Z-Purlin;Allows sloped roof applications. threaded rod to hang plumb. •Accommodates 3-1/2 x 12 pitch. •Allows 17°deflection from vertical. ,.Q 3B" 8137957 SH-DSTR1' 114-20x 1" 3220(3196') 1500 1475 .035' 3/16" 25 125 } 1111 1k 'Includes retaining nut (Does not compy with ROHS requirements) #14 Black Nut Driver The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact w/h the material you are'nstalling into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for Installations. —,3/ For the most up to date information,visit wwwsammysuperscrew.com 6 lr-`7�