Permit IN CITY OF TIGARD MASTER PERMIT s COMMUNITY DEVELOPMENT Permit#: MST2022-00035 T F G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 02/17/2022 Parcel: 1 S134DA08900 Jurisdiction: Tigard Site address: 11350 SW THUNDER TER Subdivision: DAKOTA MEADOWS Lot: 22 Project: Murray Project Description: Repair water damaged wall framing and replaces damaged wall sheathing and replace wall cap flashing. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $7,500.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bekflw Prevntr: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp 8rvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201.400 amp: 0 201.400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: MURRAY,DAVID S PURE ENVIRONMENTAL NW Required Items and Reports(Conditions) 11350 SW THUNDER TER 6206 N FESSENDEN ST TIGARD,OR 97223 PORTLAND,OR 97203 PHONE: PHONE: 503-569-8425 FAX: Total Fees: $347.83 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9..nn11V11n fh�,,.,h rrlARR OS9_n V..,,,n1_nnon M21/ a rnnv of+ha mlac nr dimM n noetinne to fN INr.by rallinn Sn'9'29 1QR7 nr 1 Rnn'+349�'9142 Issued By: C�`�—' ,Q3 "'��'_9_9'/ Permittee Signature: On ago l lc--.\ 1 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit ApplicatioECEIVED d Residential JAN 3 1 2027. FOR OFFICE USE ONI.1 Permit No City of Tigard CITY OF TIGARD Receivedewa'1 43 e 20Z2' • 13125 SW Hall Blvd.,Tigard,OR 97 Plan Review 1 Phone: 503.718.2439 Fax: 503.598LDING DIVISION Date By; '/Cb 2Z J rt Other Permit: T I G A R D Inspection Line: 503.639.4175 Dale ReadyBy: / J 0 See Page 2 for .11 Internet: www.tigard-or.gov No dMfeth l�Y/) f / Supplemental Information / / // TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ['New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ElCommercial/industrial Valuation: $ 7,500 0 Accessory building 0 Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 11350 SW Thunder Terrace New dwelling area: square feet City/State/ZIP: Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Wall RvP,,ir�/?��, Covered porch area: square feet Cross street/directions to job site: SW North Dakota Street , C' Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: 08900 Permit fees*are based on the value of the work performed. Tax map/parcel no.: 1S 134DA08900 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Valuation: $ Repair water damaged wall framing and replace rated damaged wall sheathing.Replace wall cap flashing. Existing building area: square feet New building area: square feet ❑ PROPERTY OWNER 0 TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: El APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES* Business name: Property Damage Solutions (Please refs to fee schedule) Structural plan review fee(or deposit): /.2706 Contact name: Marcus Jones Address: 2850 SW Beaverton Hillsdale Highway,Suite 106 FLS plan review fee(if applicable): City/State/ZIP: Beaverton,OR 97005-1354 Total fees due upon application: Amount received: Phone:( 503) 720-9100 Fax: :( ) E-mail: mbj.consulting(a_)outlook.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name: Pure Environmental Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 8206 N Fessenden St. Solar Installation Specialty Code checklist. City/State/ZIP: Portland,OR 97203 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 503 )569-8425 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: 229863 �yI ^ Total fee due upon application: $201.60 Authorized signature: ratc,4.2 O This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Marcus Jones Date: 01-31-22 *Fee methodology set by Tri-County Building Industry Service Board. 1:1Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I1/02/COM/WEB) Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONLY City of Tigard Received Permit No.: U 13125 SW Hall Blvd.,Tigard,OR 97223 Associated I Phone: 503.718.2439 Fax: 503.598.1960 Aasaciated permits: - 24-Hour Inspection Line: 503.639.4175 0 Electrical 0 Plumbing 0 Mechanical T I G A R D Internet www.tigard-or.gov 0 Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No NIA 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ® ❑ 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. 0 ® 0 3 Verification of approved plat/lot. 0 ❑x 0 4 Fire district approval required. Name of district: • 0 ® ❑ 5 Septic system permit or authorization for remodel. Existing system capacity 0 ❑x 0 6 Sewer permit. 0 ® 0 7 Water district approval. ❑ ❑x 0 8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 0 0 9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- 0 ❑x 0 basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ® 0 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if ❑x 0 0 there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ 0 ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑x 0 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑x 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 ❑x 0 Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 x❑ 0 prescriptive path analysis provide specifications and calculations to engineering standards. , 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑x 0 systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 x❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. ❑ 0 0 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ 0 0 for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 0 architect licensed in Ore ton and shall be shown to be a.plicable to the .ro'ect under review. JURISDICTIONAL. SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 0 0 24 Two(2)sets each are required for Items 16,19,20 and 22 above. 0 0 0 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 0 0 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 ❑ 0 27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 0 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ 0 Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 0 0 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. :1Building\Permits\BUP-RESPennitApp.doc 02/24/2011 440-4613T(II/02/COM/WEB) A City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT 'PI . Building Permit Review — Residential TIGARD Building Permit #: A. ,2OZZ^c 235 Site Address: ((35d Sot 1-14,vviIif Terr be_ Project Name: MOrr 1 __ _ Lot #: 2, . Planning Review ,, ` Proposal: (24y1O C e, `-Pac,�P.rifJ v- a�� .�v �tl� ! vVl e' �t —F c- kiei ca Verify address/suite #active in Accela. ❑ In River Terrace: l)No El Yes,River Terrace Review Addendum Site Plan Elements: $ copies of site plan on 8-1/2"x 11"or 11 x 17"paper es wi rip • Drawn to scale(standard architect or engineer scale) Footprint of new structure(including decks)and FI-'b p1North arrow wan ®Site address,project or subdivision name and lot number ❑Sidewalk/duvcway approach Applicant information(name and phone number) s ❑+sit iliiii1m7oi,,a..cH,mld...g N.Abaa. -dii..ensr9^` 1n5ree ee , Street names Existing structures on site ) b 1 ' ercenta e of covera e and >1,000 sf o - tea crest ce . es ❑No impervious area(app ca e - , , If yes,is a st qua rty facility s owo Yes ❑No Water Services-Service Provider Letter(lot platted prior to 9/10/1995 : Required: s applicant was notified X No coved: El Yes ❑ No El Water Meter Fixture ksheet-Additions,Remo ADUs Required: ❑ Yes,applicant was non Received: ❑ Yes 0 No ❑ SDC Exemption for ADU a li . ❑ e No Received: ❑ Yes ❑ No ❑ Public Fa . ovement (PFI)Permit: Require : ❑ Yes,applicant was notified et2 No Applied For: ❑ Yes ❑ No,stop intake 0 Land Ucc Caac tt: Zoning: cZ 1 2-- la Required Setbacks: Front: S Rear: 6 Side: Q Street Side:w Garage: S C� Building Height: Max. Height: 3 t Actual He ht: pLandscape Area: '7-0 % zi Lot Coverage Max: Entra ❑ Set back no more than 8'from street-facing wall ❑ Parallel to stre r offset 45 degrees or less Windows ❑ 12%of area of all street-facing facades Garage ❑ Garage door is d widest street-facing wall es ❑ No,one of the following is met: ❑ Door extends no mo 5'from wall and is a covered porch extending beyond garage. ❑ Door extends no more than 5'from there is a 12 sq ft.window above garage on 2nd floor. ❑ Garage door width is ❑ 12'or ❑ 50%or less o 60%or less and includes 7 of following: ❑ Covered porch ecessed entrance ❑ Wall offset El 1'Roo ❑ Roof offset ❑ Fire shingle ❑ Lap Siding El Roof pitch ❑ Gable,hip,or gambrel roof er ❑ Acc siding ❑ Window trim ❑ Window recess ❑ Window projection ❑ Balcony IL—SeiTsitiT'e+ft"-€1 _❑ Yes{ ❑ Nn Type: t Notes: Approved By Planning: Date: 2-1(/2.407'2- Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: 0 Approved ❑ Not Approved I:\Building\Forms\B IdgPennitRvw_RES_122419.docx Building Permit Submittal Original Submittal Date: D!/W/2.u22- Site Plans: # Building Plans: # 3 Building Permit#: [ 'Enter building permit#above. Workflow Routing: 11141anning ❑ Engineering ❑ Permit Coordinator IE1,13uilding Workflow Sign-off: WSign-off for Planning(include notes from planning review) Route Application Documents: Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. . [ 'Building: original permit a e. cation,site plans,building plans,engineer and beam calculations and . .st d: ails,if applicable,etc. Notes: By Permit Technician: = i' Date: Q_ /O?Z • Engineering Review —7 ❑ Slope at buil.: g pad: ❑ Conditions "Me ' .rior to issuance of building permit ❑ Easements (encroac ents)per engineering conditions of approval a : plat O Water Quality/Quantity .cility: Assess Water Quality Fe- . -lieu: ❑ Yes al No Assess Water Quantity Fee -eu: ❑ Ye ❑ No LIDA Facility on lot: I es ❑ No Add Fee: ❑ Yes ❑ No ❑ Final Plat Recorded: ❑ NOT Approved by Engi - •ring: Date: Notes: ❑ Approved . • ngineering: Date: Revisions (.fter Building Submittal only) Rev er Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Permit Coorth : or Review ❑ Conditions "Met"prior issuance of building permit ❑ Approved, NOT Release.. Date: Notes: Revisions (after Building Submittal only Revision Notice 1: Date Sen Applicant: Revision Notice 2: Dat- 'ent to Applicant: ❑ SDC Exemption: a Received ❑ Do-- not apply ❑ SDC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes ❑ N/A Tigard Trans SDC: ❑ Yes • /A Parks SDC: ❑ Yes ❑ N LIDA ❑ Yes ❑ N/A ❑ OK tI ssue Permit - Approved by Permit Coordinator: Date: I:\Building\Forms\BldgPermitRvw REs 1208021.docx