Loading...
PFI2022-00022 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PFI2022-00022 13125 SW Hall Blvd.,Tigard OR 97223 503.715.2421 Date Issued: 02/02/2022 Parcel: SEG2653 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Job#M2818564 Project Description: Contractor to trench and install conduit. PGE to pull wire through contractor installed conduit. PGE to replace streetlight. Class of Work: FEES Type 1 -Utilities(gas, electric,data) Description Date Amount Total Owner: REQUIRED INSPECTIONS Call 503-639-4175 for the IVR inspection request line or visit the City of PHONE: Tigard website at www.tiaard-or.qov to schedule inspections online. Contractor: PHONE: Applicant: RICO TORRES SOLIS 2213 SW 153RD DR BEAVERTON, OR 97003 PHONE: 5036725417 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PFI2022-00022 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a dean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings,mailboxes, etc. shall be reinstalled or replaced,with like kind of material.Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept.of Transportation, FHWA, current edition,American Traffic Safety Services Association [ATSSA],and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices,Flag persons,etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic,at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503 29-0111 (Tigard Police Dept., Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m.unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080.Copies of said rules maybe obtained from the Center by calling 503-246-1987. If you have any question about the rules,contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15- UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads,ditches,etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance,and all attachments,and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all ass+gnment changes. PFI_Utilities 26- RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements,shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI—Utilities 31 -OTHER Applied Notice Other City of Tigard PFI#: PFI2022-00022 ENGINEERING DEPARTMENT Public Facilities Improvement (PFI) Permit PROJECT INFORMATION TYPE OF WORK Project name: PGE Job # M2818564 B TYPE 1—Franchise Utility Work Contractor to trench and install conduit. performed byNWN,PGE, or utility Brief description of project: agency PGE to pull wire through contractor installed conduit. ❑ TWE 2—ROW Sidewalk/Driveway/sewer PGE to replace streetlight. Work performed for the purpose of: • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and Location (address if available): 16585 SW 92nd Ave main line tap ❑ TYPE 3—Full Scale Development Work Tigard, OR 97224 performed with land use approval which includes any of the following: • Subdivisions or Partitions APPLICANT INFORMATION • Street widening Name: PGE [Submitted by Jeremy Sprague] • Mainline installation for sanitary sewer, storm sewer, Tigard water, and Tigard Mailing address: 2213 SW 153rd Dr water service area City/State: Beaverton/OR Zip: 97003 ❑ TYPE 4—Small Cell Technology Phone: (503) 672-5446 ❑ TYPE 5—Tigard Triangle Email: crewcoordination-western@pgn.com phone: NOTE: Type 1 and 2 applications may be Contact name: Rico Torres Solis emailed to rowpermits0,tiprd-or.g_ov. Phone: (503) 672-5417 Email: crewcoordination-western@pgn.com CONTRACTOR INFORMATION ❑ Same as applicant Name: Brian Clopton Excavation CCB Number: CCB # 50337 Mailing address: PO Box 509City/State: Wilsonville/OR Zip: 97070-0509 Phone: (503) 209-1163 Email: brian@cloptonexcavatin.com ENGINEER INFORMATION Name: Mailing address: City/State: Zip: Phone: Email: ADDITIONAL INFORMATION Estimated value of workis required(if over$5,000):$ (within the public right-of-way) Is work related to a LAND USE DECISION? ❑Yes 0 No Case number: City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 wx N wtigard-or.gov • 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as`Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid fianclvse or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I,the applicant,certify that • To the best of my knowledge, all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. 944-� 9i,La!� Jeremy Sprague 01/24/2022 :lpplic is or a horized agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY Case No: PF12022-00022 Permit fee: Received by: HPollard Date: 1/24/2022 Approved by: 1 2 Date: V-r ' y. Notified by: L _Date: Z Z / V/ city of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 www.tigard-orgov • 503-718-2421 • Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 101/6 of the Net PFI Pemait Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7% (less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR ONLY • ONLY TYPE 4. SMALL WIRELESS FACILITY ' DETAILED SUBMITTAL CHECKLIST REQUIREMENTS Does applicant have a right-of-way license? ❑Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered?(check all that apply): ❑Small Cell ❑Macro ❑ Street Name How many install sites are proposed as part of this permit ❑ Site Address application? TYPE 3-Must provide 4 sets of plans(sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: ❑Public Right-of-Way ❑Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes(City,Water,Sewer,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineer s Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval Cityof Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • wwwtigard-ot.gov ' 503-718-2421 • Page 3 of 4 I? sw "�. � I Ed a of Pavement I -W— Ditch �r Streetlight I e —...JM. .......... ... I -Ir._ w.s I I 1 1 —SrTiTe'— i n 1 Existing House 1 rl Existing 1 F, I � Driveway a� I Q,J'� 1 O Existing Shop Powerpole I 1 o a , 1 I 95 — Wope—[iy'Une--•---• I Lant (FN) � I 1 Yryt, Scale: 'I"=30' I I 1 TYPE 1 AND TYPE 2: MINIUM SKETCH REQUIREMENTS (Put N/A if � I � � I I 1 I � I not applicable) North arrow Property lines&dimensions Existing utilities locations (sewer, storm,water) Street&street names All existing structures Proposed work Existing curb or edge of pavement Utility&street light poles Existing S/W or D/W apron Slope of property Trees City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwcvtigard-ongw • 503-718-2421 • Page 4 of 4 LIGHTING LEGEND ______ MEISLL].r,o.Lr+W 1111CIRWYJ NMIO 1p MC LOSTURT PRWO[O t M1Y{FO BYCI4 r03N11 SOMMEMCOWM IRWENI.YUIIOINBOUNIOM[R 16415 O CVSIOKIr IY 1ILLN/IM SACIIKM/JINCINAYPOR Renu pw lm LSOIIN MFeexcDBRR wwIIupxr �Kw]v FrBIRpLA33 DCYB Np1II FOL[ IMMO 3[Ir 3 BFN N0 CVM[[M [OMY[[I]u VOLi3 BE R[N.IC[EMOTUUI1LOLNMNl01 ]0'U,IN Wn iy 43WLM 011llN 001"COSRS MAY UI Nana TONNSOILMONNISROUNINNOOL, rMN I ..R I CJAL I I e/ ul I IB)eT I n C 10 W73 x•.P..e. [ Vrdy I 9111 •'., aL]!9 M'1%, 'STIr 1 (l i� ',11a}bi A}'L1 3 IT ♦ I CS �LJ 1 1 v NlM ^ MSD SIY//�Ayy 6� POBI Yres L G4 MITIleges`\ ��� M3 9► ____c as0uiz�'�4W4 h55ETMB835J �-c ..0 1lm C21-14A ac a+ GAY IBM EW Ilk CONSTRUCTION NOTES: SLCST r 4 .1.BU*TOPCwroLF Ru•RENOUNi. 6Yl]ll UW nnIV1E r.. N Y....WEPEq..,NM M[APLN,..RM FWrdLiCReiOBE iNBiNIEOmL Wv gFEgyE p,6AlRIGL cRYfE.wfLL. OE M74 NI WRMLe1PLLLSTRWaSOM MOLES UBSU PoE TO T£rERNmE]Ne e¢eFM MINpry CFCMwmspWUNEO RUTUTNTS NIRRi2(FIiH mpEe 0.EARNFE BEMEflI ObMOOMER UIE FAM.ML ELNiWBL INp 65MADER 10 BE I N.CH FANU6 ST INHO9NIAIBEDSTEEL OMBINMULLE LESCLET LK[iR SSITSMATOBE NC SO11' 'FULIOEELOR PoENIOOPhLFPF7HNLPPEI. .RE RFWPID rMITHUSUSUBUTLE r 31 CSM ORCECEMUEISRENVBIUUF I4UNNILIOSREM.N KECUE Ttt t$VO MRE OTIMS AXIWYMTALp[NWiNAW CCMW1i RUH le P0D6pEEB. 2 AAM pANCIV CMW I SCI OUNMENE010RTIES.I LEN OMNECPOE VM FIB, B'a'N A1T5 91dx y MWIWrTSNNDPULLTWUNUSCALLITBENNOT[COWINTOIETI]M1I.1}]R]M.IATOu 404 1 V rT DANELMkLrOE 6ONpOV WCW I98i / FW'INUU NMO TO BE MOUNTED MRX TCI M eV[ BINI. 4 e®IryERROPoMSMEIMMMUCAONS....NISI Wv FRCYFNOFENI LME TOPROMENIILFE.CRWt)FORI ff R IrR]ED DEEP LWIIr6IFMM FYNLOMCE. THINK p OpE<TIO14 porINC REaNREMENIp.rAT.�roIEa36NwKIP•aa.I,Nr3�K,w- CONIACTSEAVICECOORO/AURIR SAFETY _ awl.�IneIvYiueiY :T`""IEP"°M1 .E°H OT°,a'1`BBITIN""` [(q Of....ID(WOM Ib.FLT4m nqL NI'90r POE 9rTOR:Air[N LCffi 151Y4L19EON PEWESTNFRPI KE eR�R R TM LIMIT, YNLZ ...uwpL FIRST - FT SMErIR.EMKTNE NnT MUL1BF pro-wrx]EW.LL SP.cED 6ORINA[OR [N>t REOT RNE pM[CMUUBLATFGIAMMEINMB xir NWe]E.,FSI u� UYIMCF COORDINATOR +OPE PPF Iaxsa,]nTO.TTIOR TO ME THAT TENw1IIrBPEciro PnESEN, SQi32liJW OR 1-[OLLS[2J[ID WNEOMO[NE MBE BEI AUTOI INJ M IB SAUMI NBTA RµMN.11 WNwINOIE IINBTAUEOIxfWDKMf/ry3EnmoEruL ON,R}T BEFORE YOU DIG µ1J EATEIU•IM:NAB(NE TNf wo iifx nOx: �wNTONUIMTe/NIETPUN FTNMmw.NlcoKusrmLl .11.IS.REWMf3 YOU TO FOILOW RUlE3 ACUNEO 10'1 LOWµMM'F INSULTED eIINITRONS FROM lff ONBM BY 1M[ORf LION UTUUl NVNUNUON EFN. ITTTOANTFOROMPON MUST BE MTHIN 16 FEET OFA WNELBEMEA RIOXRUIESARESEIMITMINWRBSx.N IS WgY8 M.m *NUIGI[ApNAE INFN---TR--MBR6 MOI W N IN GTO—IO U MAY ORIAIN[ON}S OF M RU![]BY[IIIINO iME OF[LMVIMT' ITEELIMPIESOCUTBOUNNOSONEO.WWIq IwNOfPNERSTHATfMOf. . NOTIFNATIONCENI(R AONINI]rMiIVII ISO}-}}}-19hf TCV.CUB TO RfO N[FIUrIIIIYLOUIFS UEI MFORPoOR INSISTWB9 ABNrE£OEDLT MFRROC%T PUBLIC USTI BASEMENT ELF)TOMB FEUPUNI. INSIAL130AMP NsaIN 5KONd1FY PEOE5IA15ORIECONUAR NOTE UMITY NO)IFIUTION UNITER,...AT([A3r �BMN7�BB VAU(TS LWNKHEVfRI55I Li PolMOFATTACNMFNTf FOR UCH FLUE TO PANYNE BOTTOM P2CE OF POLE MR CUMMER DEVWTION FROM DESK'N MUST EBVSIII[TS dYS IMOR TO[IICAY.111QY ImES,HHONSOULT.FTPoFREPRFSEMACION OMMUNIgEBTNRMMNx..O 10 MFCNK TeI.I9ECOWTRVCION CCNFFRE]ICE.IMCLY]EOIN TNBLWfEREN3 TFEET(IGNr PU IBOCDMSTRINTNN SIANWRD(C11550 TO INSTALLAT THE SBMF TINEAS TNF CONDUIT APPROVED BY THE PGE PROJEL7 MANAGER RIGM-0F-WAY PERMIT NOTICE: MOLL IS EFCwnOq rrE.mW urv.NDMAT A BENI FROM Mf LOUL IUR6DKTOH I5 REDLINED BEIORE ANY TO B-11 M ALEN ARE PRE-CONSTRUCTION MEETING/TRENCH AND CONDU?INSPECTION PGE FACILITIES NOT DRAWN TO SCALE wopK IN THE RIGNroF-wAY MAr BE P[RFDRMfD. ONLYPGEAPPROVED INr,L wxv°".s� N_`-P" << .�N:"°pTRx:I=,:PrIPIE,EI_..Foy.}«.1•. YOLW PROJECT REQUIRES A PRECONSTRUCTION MEETING CONTACTYOURSERVICEd DESIG THIS DRAVANGISAGRAPHICAL REPRESENTATION OF PORTLAND GENERAL CONTRA[TORSAWN TRACIORSWIIOMKMADEOTWRSPECLIL �]narrc IN-1—1 A.nwE...l-wv r.Prc]woRxrrc c.'s.cPr.scec-Iov PROJECT MANAGER)TO 10 WORMING DAYS PRIOR TO EXCAVATION TO COORDINATE THE ELECTRIC FACILITES IN THE FIELD.THIS MAP ILLUSTRATES ELECTRICAL AGREEMENTS WITH AGE WILL BE ALLOWED M WORK UNDER MES PERMIT If RETER TO THE I HECTRI .p EREKAIL NT5.11 FON PkONc4WR1 YI ONNECTIVITY.TYPESAIA NUMBERS OF CONDUCTORSANO PLACEMENT OF THE CONTRACTOR MUST NOTIFY THE LOULNRISDETNN IE HOURS PRE-CON PGE'3 FIELD CONSTRUCTIONDUIT INSPECTIONS FCCIWILLPROVIDE YOURTRENCH EQUIPMENT WITHIN THE DISTpIBUTpN 6YbTEM.IT I6pfcDMMENDEDTHAT 13.¢Bw IB BAS®ONSTArp.ROUMERGxu1WEwIwExT NDNer.E U... . AND CONDUIT INSPECTIONR iME V6Efl NOT RELY ON THI6 DIAGRAM FOR GEOGRAPHICAL LOCATIONS BEFOREWORKISMSEGM.A COPY OFTNE PERMR MUSTBf ON SITE 4 DEWRMENTMAYMMV Tr NMMADMTI CaTTOIVEC.UMT ER JUNCTION BOX INSTALLAl1oN4 AeecoxarRUCrroNORAwLvc FOR STREET LIGHT ONLYGROUNDING STREETLIGHTS ON DISTRIBUTION POLES CONDLCTPOEFORAPPROVEO MANUFACTURERS -Nr I i.. ryEwl Rn DO WITH RSDEV WO M M2B21475 --•-•••.--••_•_-- K�R� STRENdIT aM1' '�I"' Gsnerpl FOrmNR: Defy: _ BRACKET SIpElLIBMI MABTARII x BryB Nm..Naw� —ERNST GREYRW' MSBULT BYOESIGh9t m.a.®1111 4– PER LC 11N0 e e I~ TMETO])A'ESCWWPESUMTANMe BEEFFECTIBELYBONDEO IBYm 1l1?1M21 1YI'.30R 10)OWt ooma Um 1RB183BL f INE CIEERANCE EETNEEN THE MACKEI ANDCOMMUMIGI/ON TOS Primm" C MNVAIMWMEW PONT IS LESS MAN40MCAES. .n ` Q REI BBUImBn I C M T BN I ES,Ne VRw EBMW 6UMi•ABicll E wKlry MU N a. N BI A MAS IAMI FOR AEWWSTALIATNMS ANO RETROFITS, M1PRN Cal^ bWO� ` DURHAM SATTLER 11122 u• TMLMEAIV BBNN/��C e x y - CONNECIAMwO ARE.IFEUTRALIMI)MAICONDUCJWtFILCW �ryE 185853W 92nI TIGARD ®��^ TIFPOLELM EN TH BEE.FINEOROLEI TURNIA0E3 A"tl YOT f]bI METI INE SERVICE NEVIIEAE NSMOWIWY•MIM. 1 If . , TF EMI/avMuraEunla]aAr N4B L.— RbR BBB 42LEDf aM DDRIRe 24OJ MCVITR PARALLEL OROO SE CLASP IO rNE MA3TAIn OyyrMW WHr ..�.., _ UBNOA J NON OROUWpTN CLASP �TUKupI a SHINGTDN C211M IFf'.15 1OF,v: `• .�........,.�as IZ Wn IJ hrT v'ESGY By 4NWEi Lms eurvcG www.invarion.com M��rtle G�ost�ret lnterse;�tiotiDagrm624 Diagram 620 covers work within an intersection when normal traffic control must be interrupted. Work vehicles may or may not be in the work space. 1. During flagging, traffic signals shall be turned off. Contact the road jurisdiction for approval and assistance (see Chapter 3). 2. For multi-lane facilities, traffic approaching the intersection shall,be reduced to a single lane on each approach. See Chapter 3 for information on flagging through intersections. 3. There should be one flagger for each approach. One flagger may control two adjacent approaches if sight distance, low volumes on side roads, and flagger position allows for safe operation and clear direction to motorists. For low traffic volume intersections (fewer than 400 entering vehicles per day), one flagger may be used. 4. The "ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues may be expected. Sign Spacing and Buffer Lengths (feet) " 1? ERRATA: C �.Y 20 50 25 100 100 100 75 Supplement Table 30 100 35 125 Updated:February 12, 350 350 350 40 150 2016 45 180 By.ODOT Traffic-Raodway 50 500 500 500 210 section 55 250 Signs Spacing and Buffer lengths (feet) Supplement --+-11tr3+.4 t y,x..-• e S. .. oe ME Ina, 54 M®R 60 285 65 700 700 700 325 70 365 wwww.invarion.com ♦ Cs'na`i > ak�tCf Z*r } 5 xF ♦ ,#a kfi'3 4 r7 s�NRsi � rs Ri ri13Y`Ak � '•s�.v '^y t'`�t any �}� [/'n'l£3 rly'>' �ne�fGlosureilaf�lnte�a`ezctl�h,zw�t����a�g�n� ��,���1�t��;����l�agt�a��62Q '^;aY9s`�Wy.Y'M'La „4'i •si°'�1 c >l >>fs.-44y^L dF 4�:>n.,S`4.1.�k..> a^r.i a 5.y.':` .r.'t.}Y<> �s r�u.,r.... �'r.�, r ROAD WORK AHEAD ONE UTNE C (Opllonal) ROAD AHEAD B HE PREPARP.O ' TO STOP <* B A (Optional) 0 ONE LANE ROAD p NE AHEAD ROAD 160Max. O PREPARED WORK O TO STOP AHEAD A 6 B C O a a 0 0 0 a 0 0 T 100 fl.Max. 0 0 A B 6E PREPARED TO STOP B (Optional) ONE LANE ROAD AHEAD C ROAD WORK AHEA