Loading...
PFI2022-00037 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12022-00037 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 02/10/2022Parcel: SEG2363 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Ziply Fiber 5511442 Project Description: SEG 2363/2205/2204-Ziply to tranfer/splice/remove copper cables from existing PEDS to give room close to PED casings Class of Work: FEES Type 1 - Utilities (gas, electric, data) Description Date Amount PFI Permit Fee 02/09/2022 $300.00 Owner: Total $300.00 REQUIRED INSPECTIONS Call 503-639-4175 for the IVR inspection request line or visit the City of PHONE: Tigard website at www.tigard-or.gov to schedule inspections online. Contractor: PHONE: Applicant: MICHELLE ROSE 6074 N DISCOVERY WAY BOISE, ID 83713 PHONE: 2085764031 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12022-00037 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03 -WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA,current edition,American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices,flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue)and to 503-962-8140(Tri-Met)and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08 -TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15- UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities (roads, ditches, etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms,conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2) persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 26- RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27 -PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance). PFI—Utilities 31 -OTHER Applied Notice Other City of Tigard PFI#: PF12022-00037 ENGINEERING DEPARTMENT Public Facilities Improvement (PFI) Permit PROJECT INFORMATION TYPE OF WORK Project name: 5511442 ❑ TYPE 1—Franchise Utility Work Brief description of project: Ziply to transfer/splice/remove copper permed by NWN,PGE, or utility agency cables from existing PEDS to gove room to close PED casings ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer SEG 2363/2205/2204 Work performed for the purpose of • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and Location (address if available): 15785 SW75nd Ave Tigard, OR 97224 main line tap ❑ TYPE 3—Full Scale Development Work From SW Upper Boones Ferry rd along SW 72nd up past SW Kable performed with land use approval whicb includes any of the following: • Subdivisions or Partitions APPLICANT INFORMATION • Street widening Name: Ziply Fiber • Mainline installation for sanitary sewer, storm sewer, Tigard water, and Tigard Mailing address: 6074 N Discovery Way Ste 125 water service area City/State: Boise, ID Zip: 83713 ❑ TYPE 4-small cell'rechnology Phone: 208-576-4031 ❑ 'TYPE 5—Tigard Triangle Email: permitting@mountainitd.eom Phone: NOTE: Type 1 and 2 applications may be Contact name: Michelle Rose emailed to rowpermitsQuprd-or.go<. Phone: Ernail: CONTRACTOR INFORMATION ❑ Same as applicant Name: NorthSky Comm CCB Number: 208747 Mailing address: 11818 SE Mill Plain Blvd Ste. 410City/State: Vancouver, WA Zip: 98684 Phone: 503-209-6856 Ems: geastonguay@northskyeomm.com ENGINEER INFORMATION Name: Russ Wells Mailing address: 4155 SW Cedar Hills Blvd City/State: Beaverton, OR Zip: 97005 Phone: 503-643-1001 End: russell.wells@ziply.com ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ (within the public right-of-way) Is work related to a LAND USE DECISION? ❑Yes I9 No Case number: City of Tigard • 13125 SW Hall Blvd. 'Tigard,Oregon 97223 Nvww.tigard-or.gov • 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as`Applicant" shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I, the applicant, certify that: • To the best of my knowledge,all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. AM41 Michelle Rose 2/4/2022 Applicant's or authorized agent's signature Print name Date Property owners signature (if required) Print name Date STAFF USE ONLY Case No: f Flzoz2-oaoa7 Permit fee: -,2-�d vD Received by: NT Date: 2/4/2022 Approved by: %r'v,X13 Date: Z/912a4t Notified by: Date: 2UZZ Cityof Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 • Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR • TYPE 4: SMALL WIRELESS FACILITY TYPE 1-3: DETAILED SUBMITTAL REQUIREMENTS CHECKLIST Does applicant have a right-of-way license? ❑Ycs ❑No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered?(check all that apply): ❑Small Cell ❑Macro ❑ Street Name How many install sites are proposed as part of this permit ❑ Site Address application? TYPE 3-Must provide 4 sets of plans(sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: ❑Public Right-of-Way ❑Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes(City,Water,Sewer,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineer's Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval Cityof Tigard 13125 SW HallBlvd. Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 3 of 4 Q gin- '• �- '• � I Edge of Pavement Duch Streetlight 1 —•—•—•�'�'�•�•�r�•— 1 1 rxm n�.t . I � I I i T��ro�pSs elwer"C'i8�' I 0L) �1 1 ✓ I N 1Existing House r; j Existing j I Q I � Driveway j j " I 01 I I rl 0I 1 ' a Existing Shop 1 Powerpole I I = I 1 I I� 95' I o groper VL7W-----•—•-- l I Imo" F ydrard(FH) I 711" I Scale: I I I TYPE 1 AND TYPE 2-. MINIUM SKETCH REQUIREMENTS (Put N/A if I I I ' I 1 I 1 not appticable) North arrow Property lines&dimensions Existing utilities locations (sewer,storm,water) Street&street names All existing structures Proposed work Existing curb or edge of pavement Utility&street light poles Existing S/W or D/W apron Slope of property Trees City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.figard-or.gov • 503-718-2421 • Page 4 of 4 Page 84 2011 Edition Stationary Lane Closure with Flagging Diagram 320 Diagram 320 covers total closure of one lane of a two-lane, two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340— Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the"Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The"ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 September 2016 2011 Edition Page 85 Stationary Lane Closure with Flagging Diagram 320 03Q O w Cd \ A W • W a o� O 0 0¢ 5 I a`) rn m °S A1 t 0 a'' O maN ?i a Q ----------------- • me • =.ov I I •• >°a I • 00t MO 1 t I Q�Ln 3 I I • I.: d •• c 8 m I o • I aE 13 • I ° v • m> I CO o< • LLJ— < � B g I �� I r mW l t / ¢o Sign Spacing and Buffer Lengths(feed c posted Spacing Between Signs "Buffet 1 1 \ WW oo Speed A B C Space ]G D 20 50 z2� O Z5 100 100 100 75 O 30 1 100 35 350 350 350 125 40 150 .O 4s Iso ¢3 50 Soo Soo 500 210 5s 1 2So 60265 65 700 700 700 325 70 365 September 2016 Chapter 5 NO JOINT POLE NOTE SW Kable L+, TOTAL ALLOTTED HOURS CONSTRUCTION NOTE �© Compunet9 CREW A"Ne w'ro'uwCAP.. X-D� Aa M1. C1 l-TIME MAI . cellur1-THIS WO IS OPERATIONS DRIVEN- Consumerwarehousev SPLxaxc o D o O DErveR 13 6RGW1N SERVICE INTERRUPTIONS POSSIBLE IF FTIT Yx FITP OWRLAT �e i"C NOT WORKED FINER Trinity Flooring CONDUIT ONLY 2-CIN OF TIGARD PERMIT REQUIRED v O-Portland '., 'INNTRUCTION START Fee,p VeRe IN SERVICE DATE J Of Ore n QBridgeport Distribution CONSTRUCTION ca4PLCTE go Halve gco,rtae Carman Dr'I CUTS REQUIRED CONSTRUCTION Bridgeport Distribution Q 13 YES ONO Merht Peterson TTIxr TRExCa O nxAL. A nxc 13 TER OND CONSTRUCTION CONTACTS - OFLAwING SCCN REp'D REED JHORT-971-343-2450 trm pies ONO �REQ'D xxNN JAMES STAATS-503-758-3119 •15797 S 872nd Ave, Tigard,DR 97224 �o TT TS SCHEDULING CONTACT 9SN NDNICIPALITY clTrmcARD MUY ICI PALITY RYAN ROBERTS-503-643-3713 to Inc y�J Q NICL�'R1TIFPIC HaIrCIubQ ® p DaTAILED (NOT BLANKET) Animal Dental Clinic NTS o NO ENNNIT ANQDIRND FACILITIES CONTACT 8 Oral Surg ROBYN RUSSELL - JOINT POLE 503-260-9525 SHEET 1 OF 8 JT"INJNN" I JFx/1NTNNE , NORTH Dao TEN NEgainNn INSPECTION CONTACT OM R TO "ON TROY ULLRICH-503-765-4900 13 O O EONNR 0 0 0 CAW 0 0 0 FRONTIER ENGINEERING CONTACT ******2022 CAPITAL WORK ORDER**** POINT OF CONTACT RUSS WELLS 503-312-7330 RUSS WEUS 51351-5511442 503-643-,N1 THIS JOB IS OPERATIONS-CABLE SCREDYLING RYAN ROBERTS PNOxE N0,503-5413113 MAINTENANCE DRIVEN-COPPER CABLE „Dae"„oeailuaLS LABOR HOURS EXPOSED-PEDESTALS WILL NOT CLOSETECH PHONE NO, AND CASES CANNOT BE CLOSED. FIELDED NY RUSaWELLG MATERIAL REQUIREMENTS SPLICE-C-0-M-48-X-16 POSSIBLE SERVICE INTERRUPTIONS CREW-C-0-M-4-X-16 POSSIBLE.REMOVALOF Zlplyfiber "'NONE— SONICOM-FLAGGING-56 UGAE:300-24 —REMOVAL OF COPPER TGRDORXA/COPPER CABLE RETIRE CABLE ONLY-ABANDON IN UGAEB 28-22 SCREEN 15785 SW 72ND PLACE-REMOVE FROM ABANDON CABLES IN PLACE PR03ECT CO AREA NUMBER 5511442 excN.cONesa, PEDESTALS REMOVE OUT OF PEDESTALS 51351-5511442 D2A INTE c...E Rws STz�ial0 lie was_ WSCALE.1.100 TAAOISTRICT NWI. , Or 9 IND RNG. SEC'. w SEE SHEET 3 ------------- I v X yF „M„SPLICE UGAKF.100-24 °A"'010 FROM(BBRIV 481,2301-2400) TGRD P2F3 TO BBRIV 481,1926-1935+ � XD,11-100 w TI Q I u I 1I o 15500 15605 SW 72ND AVE VBBRIV ��I 3 SW 72FINDAVE ALL FIBER CABLESP 11345 ,F U) BBRIV OMITTED CLARITY FOR Q K 17✓6=025` R F TGRDORXA ;III S \ MI-Ill 402 IIF 15662 O 15785&15787 ; C SW 72ND AVE SW 72ND AVE I D N E G eRl�BosI /,/ NTS A' SHEET 2 OF 8 M / / NORTH -- --- J ILU F a 0Qo�y r N S�Jee� f ziplyfiber % N TGRDORXA/COPPER CABLE RETIRE 15785 SW 72ND PROJECT CO.AREA. NUMBER.5511442 EXCH.COOS.51351 51351-5511442 LRAw LATE ENGR Russ wEu N wASH I R]W2 PHONE F.4331?TSD FILE. SCALE:1�1pp T"DISTRICT . 2 OF 8 TWNSHP. RNG I SEC'. /EEEE TRANSFER AT BBRIV T 17045 BBRIV4R7 WORKING SERVICES TO TIGARD MH 7233 SW KABLE LANE 581,976-1000 3/339 II s BB "M"SPLICE BBRIV 5R1,976-1000 FF-,2 SPL-UGAKF:100-24 II BB� °'uD20 IN UGAKF:200-24 (4R1,2151-2250)TO zs o au.om 481,2151-2225+581,976-1000 ( cc xs o L_ 7257 SW KABLE LANE \ BBRIV 481,2101-2125+X0,26-75+ggRIV 481,2176-2246+1 XD,1-75+BBRIV 581,976-1000 ` + / BBRIV 4R1,2101-2125+XD,26-75+BBRIV 4R1,2176-2246+ XD,147+ggRIV R1,2248-2250+XD,1-175+ggRIV 5R1,976-1000 CC TRANSFER WORKERS IN BBRIV 4R1 COUNT AT 7337 SW KABLE LANE i BBRIV T 17044 TO BBRIV 5111,976-1000 COUNT x 0 BB UGAKF:200-24 XD,1-175+BBRIV 5R1,976-1000 5 II-TRANSFER AA buvio WORKERS IN 3 0 BBRIV4R1 COUNT TO BBRIV 581,976- 11 1000 I NTS BBRIV 77765i TIGARD MH ' TIGARD MH 2/295 I SHEET 3 OF 8 GGFF I 2/338 2F4/338 I NORTH HH— --Z------- ' —-—- ------Y -- I SW KABLE LANE TIGARD HH (4) 2/29551 I I I. f ziplyfiber X TGRDORXA/COPPERCABLE RETIRE U it I 15785 SW 72ND FROJECSEE SHEET 2 Numam �O CO Hux1RFR:5511442 e^cH.cone:sal 51351-5511442 Pxo�He. sRa 3 x-33o xE SCALEI-10S ITMDSMICT: OWO 3 OF S TMNSHP JRW Imc: A 490' AKF:900-24 2422.101 r G BBRIV T9546 ` BBRIV 581,701-775+XD,76-100+BBRIV `BBRV 481,2301-2400 J 4R1,1901-1975+XD.176-185+ BBRIV 4R1,1986-2400+XD,601-750+ BBRV 4R1,1926-1935+XD,11-100 BBRIV 5R1,951-1000+XD,601-825+ BBRIV SR1,1026-1050+XD,851-900 B UEB:28-22 2422.102 H UGAEF:100-24 XD,1-28 XD,1-25+BBRIV 4R1,1926-1975+ 5460-2612490 01.1990 321' XD,76-85+BBRIV4R1,1986-2000 ABANDON IN PLACE CUT OUT OF PEDESTAL 8057 1 BBRIVT18178 C UKF:400-26 XD,1-25+ BBRIV 5R1,701-775+XD,76-100+ BBRV 4R 1,1926-1975+ 101-150+BBRIV 5R1,950-1000+ XD,76.85+ XD,301-000 BBRIV 4R1,1986-2000 C UKF:400-26 J UGAKF:200-26 BBRIV 5R1,701-775+XD,76-100+ XD,1-25+BBRIV 101-150+BBRIV 5R1,950-1000+ 4R1,1926-1975+XD,76-85+ XD,301-400 BBRIV 4R1,1986-2000+ XD,101-150+BBRIV D AKF:300-24 4R1,2126-2150+XD,176-200 BBRIV4R1,1901-1975+XD,76-85+ K 75' BBRIV 4 R 1,1986-2100+XD+201-225+ UGAEB:28-22 BBRIV 5R1,1026-1050+XD,251-300 XD,1-28 5460-2812490 01.990 75' ABANDON IN PLACE CUT E AE:300-24 2423.102 OUT OF PEDESTAL BBRIV 4R7,2251-2400+2126-2150+2101- 2125+2151-225D L UGAKF:300-24 ABANDON IN PLACE/RETIRE BBRIV 4R1,2601-2700+2501-2600+ 5460-0121784 01.1979273' BBRIV5R1,1301-1400 REMOVE-CUT OUT OF PEDESTAL 8057 I M BBRIV 712977 ZI ly fi be F UGAKF:100-24 BBRIV 4R1,2601-2700+2501-2600+ SHEET 4 OF 8 BBRIV 4R1,2301-2400 BBRIV 581,1301-1400 TGRDORXAICOPPER CABLE RETIRE F UGAKF:100-24 15785 SW 72ND BBRIV4R1,1926-1935+X0,11-100 "CAUTION"-4 WIRE CIRCUITS IN BBRIV 4R1,1936-1975 51351-5511442 NUMBER 5511442 EXCHCODE.5MI DRAWN GATE- NOR ON RU66 WELL NTY'. ,2]2012 PHONE. 503.91]-Td3B ILE SCALE'.1.500 ITMDVRICT: DWG A OF 8 TMSHP IRIM: BEC: N UGAEF:25-24 V UGAKF:300-26 BBRIV 4R1,2126-2150 BBRIV 5R7,701-775+ XD,76-100+101-250+ BBRIV 5R1,951-1000 O BBRIV T 9266 BBRIV 4R1,2126-2150 W UGAE:100-24 BBRIV 4R1,1901-1925+ BBRIV 5R 1,1026-1050+ P UGUKF:400-26 BBRIV 4R1,2251-2300 BBRIV 5R7,701-775+XD,76-100+ 101-250+BBRIV 5R1,951-1000+ XD,301-400 BBRIV4R1,1901-1925+ BBRIV 5R1,1026-1050+ Q UGAKF:300-24 XD,51-100 BBRIV 4R1,1901-1975+XD,76-85+ BBRIV 4R1,1986-2100+XD,201-225+ BBRIV 5R1,1026-1050+XD,251-300 X BAE:300-24 TGRDORXA 481,2251-2300+ 11/ 2001-2025+2126-211 R BAEM11-24 2151-2250 BBRIV4R1,2251-2400+2126-2150+ 2101-2125+2151-2250 5460-0901189 01.1979 729' ABANDON IN PLACE/RETIRE 5460-0121784 01.1979 55'2423.102 2423.102 ABANDON IN PLACE/RETIRE S UGUEB:28-221 Y UGAE:300-22 XD,1-28 I XD,1-100+ BBRIV 5R1,701-775+ 5460-2812490 01.1990 74'2422.102 XD,176-300 ABANDON IN PLACE/RETIRE T UGAE:100-24 BBRIV 4R1,1901-1925+ Z UGAKF:300-24 BBRIV 5R1,1026-1050+ BBRIV 481.2101-2125+ BBRIV 4R1,2251-2300 XD.26-50+BBRIV 4R1.2151-2250+ BBRIV 481,2001-2100+ BBRIV 5R1,951-1000 1t UUGAKF:400-24 XD.1-250+ 1 zipl fiber BBRIV 4R1,2251-2300 BBRIV 581,951-1000 2001-2100+2101-2125+ SHEET 5 OF 8 TGRDORXA/COPPER CABLE RETIRE 2126-2150+2151-2250' 15785 SW 72ND NUMBER:5511442 Eiccc..,,.l 5480-4POO1 EA 01.1998 96'2422.102 51351-5511442 oRave+waE. ENGR Ru Eu Nn: 1mR1R2 T"DIS RICT .TS.. ae. ABANDON IN PLACE/RETIRE scue i•im IT"DISTRICT oMc s oR e 1YM SEW, IRNG. SEC'. AA UGAKF:600-24 EE 100 PR PROT TERM BBRIV 17045 BBRIV 4R1,2101-2125+XD,26-50+ r BBRIV4R1,2201-2246+XD,47+ ` BBRIV 4R1,2151-2153+XD,54+ ` + 1 BBRIV 4 1,21 - + + tSbKIV _ BBRIV 4R1.2248-2250+2001-2100+ > XD,251-550+BBRIV 5R1,951-1000 EE 100 PR PROT TERM BBRIV 17045 XD,1-50+ XD,1-550+BBRIV 5R1,951-1000 X1,951-1000 BB UGAKF:200-24 BBRIV 4R1,2101-2125+XD,26-75+ FF UGAKF:100-24 BBRIV4R1,2176-2246+XD,147+ BBRIV4R1,2151-2250 ) 1 BBRIV 481,2151-2225+ 5R1.976-1000 ] XD,1-550+BBRIV 5R1,951-1000 XD,1-75+5R1,976-1000 CC 2-100 PR PROT TERM BBRIV 17044 GG TGRDORXA 55P2 PEDESTAL BBRIV 4R1,2101-2125+XD.26-75+ BBRIV 481,2176-2246+XD,147+151-200 HH BAE:200-24 BBRIV 4R1 2151-2250+ 1 CC 2-100 PR PROT TERM BBRIV 17044 BBRIV 4R1,2101-2125+XD,26-75+ r BBRIV 4R1 2151-2225+ BBRIV 4Rt,2176-2246+XD,147+151-200 BBRIV` 5R1,976-1 + XD,101-200 !� DD UGAKF:200-24 XD,1-75+ BBRIV 581,951-1000+XD,51-100+ BBRIV 5R1,976-1000+ , BBRIV4R1,2201-2246+XD,147+ X ,101-200 BBRIV 4 R1,2248-2250+XD,151-200 II 100 PR PROT TERM 7765 DD UGAKF:200-24 1 BBRIV 4R1 2151-2250+ BBRIV 5R1,951-1000+XD,51-100+ ` ,101-200 BBRIV 4R1,2201-2246+XD,147+ BBRIV 4R1,2248-2250+XD,151-200 BBRIV 4R1 2151-2225+ BBRIV 581.976-1000+ ziply f i b e r XD,101-200 SHEET 6 OF 8 TGRDORXA/COPPER CABLE RETIRE 15785 SW 72ND XD,1-75+ PRwwr 5511442 sxcH.coc.D1'G BBRIV5R1,976-1000+ 51351-5511442 NUMeER. ceassl DRAWNDATEENGR: RU66WUL NiT'.WASH - lwI PHONE. 0O411ZL O ISE. SCAE1nw ITMDISTRICT: OWO 6 OF 0 T SHR: IRNG I SEC'. H3017:1-36+4XD+32X0 481:2151-2250+20 DD RBN72-5 UGAEF3-2 4R1:2101-2125+25DD 2151-2153+1DD+2155- 246+ 1DD+2248-2250+2001-2100+ 30ODD+5R1:951-1000 UGAFF6-24 m n 000 a p W Y O.b S nz ZZ in TO HH340 pOI 000 p 4R1:2101-2125+25 2151-2250+2001-210(1+ 581:951-1000 — UGAEF3-2 L54 (MH2 MH338 130+32 4844TA 2804790 UG2S1W12D KABLE LANE T O T REV 1-21-97 BKY MH338 Zlplyfiber SHEET 7 OF 8 TGRDORXA/COPPER CABLE RETIRE 15785 SW 72ND PROJECT coARE0. 51351-5511442 RUBBER:5511442 Ex OH Cox.51mi DRAMN GATE: ENGR' RU66 WELL RTY MMBH 1/Y!E I PHONE RIC.. 3J0 E: SCAlE 1.1m TAR DI8TRICT: DWG 7 OF B TMMMP. RW SEC. XD,1-50+2151-2153+ D,54+2155-2246+ O XD,47+2248-2250+2001-2100+ XD,251-300 UGAEF3-2 T T o m T 4R1:2101-2125+25DD+ T w 2151-2153+1DD+2155—22464 100+2248-2250+2001 2100 RBN72—S 300DD+581:951-1000 H3017:1-24+12XD+36XD UGAEF6-2 4R1:2101-2125+50DD+ 2176-2246+10D+2248-2250+50 UGAEF2-24 � 'I T-I RBN72—S H3017:1-36+01D+32XD 1 Q2 L54 MH3 MH339 134+11 Q3 ® 4484TA 2804790 5R1:951-1000+500 + UG2S1W12D Q Q 4R1:2201-2246+1D + KABLE LANE 2248-2250+5000 REV 1-21-97 SKY UGAEF2-2 T MH33 f ziplyfiber TGRDORXA/COPPER CABLE RETIRE SHEET 8 OF 8 15785 SW 72ND PROJECT " .AREA NUMBER 5511442 E Crv.cooE.siasi 51351-5511442 DRAwNOATE' ENGR Russwsu NTrwnsry C2 E I2 PHONE. RIOT -]330 FILE. SLALE 1-100 TA%DISTRICT'. DWG 8 OF 8 T SHP' RNG. sEG'. Page 106 2011 Edition Diversion into a Continuous Left Turn Lane Diagram 430 Diagram 430 shows work in the travel lane(s) next to a continuous two-way left turn lane with one direction of traffic diverted into the continuous two-way left turn lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. When two or more travel lanes are reduced to a single lane before the diversion, each lane shall be closed separately. Layout traffic control according to ODOT Standard Drawing TM 852 for 5-lane sections. 4. A shifting taper(L/2) may be added in the diverted traffic direction across the continuous two-way left turn lane (as shown). This option is recommended when the speed is 45 mph or greater. Sign Spacing and Buffer Lengths Ifeet) Posted Spadng Between Sipa "Buffer" Speed A B C Space 20 50 25 100 100 100 75 30 100 35 350 350 350 125 40 150 45 180 50 500 500 500 210 55 250 60 285 65 700 700 700 325 70 365 Chapter 5 September 2016 2011 Edition Page 107 Diversion into a Continuous Left Turn Lane Diagram 430 ROAD WORK AHEAD B llylt CEHIEA � I I IANE CLOSED AHEAD A I U2 I ;I I Buffer Protection Vehicle wlrMA(both Optional) /See Chapter 4 Buffer • • L/2 I � L/2 A I ly1B ,� AHEAD I September 2016 Chapter 5