Loading...
PFI2022-00008 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT = COMMUNITY DEVELOPMENT Permit#: PF12022-00008 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 01/13/2022 Parcel: SEG2488 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Zlply Fiber W0911922 Project Description: Ziply proposes to place terminal at pole 252028, place drop from this pole to pole 251173, and place aerial drop at pole 251176 at customer's location. SEG 2488 and SEG 2403 Class of Work: FEES Type 1 -Utilities(gas, electric, data) Description Date Amount Owner: Total REQUIRED INSPECTIONS Call 503-639-4175 for the IVR inspection request line or visit the City of PHONE: Tigard website at www.tigard-or.gov to schedule inspections online. Contractor: PHONE: Applicant: RUSS WELLS 6074 N DISCOVERY WAY STE. 125 BOISE, ID 83713 PHONE: 5036431001 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: Special Conditions(See Attached) Note: THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12022-00008 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association [ATSSA],and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices,flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue) and to 503-962-8140 (Tri-Met)and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFi_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities (roads, ditches, etc.)as may be necessary,as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms,conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25- EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2) persons who have authority to resolve problems,take corrective action and,in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28 -AS-BUILT DRAWING One as-built drawing showing all new public improvements,including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility,shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other City of Tigard pFl#: 2022-00008 ENGINEERING DEPARTMENT Public Facilities Improvement (PFI) Permit PROJECT INFORMATION TYPE OF WORK Project name: W0911922 ❑ 'TYPE 1—Franchise Utility Work Brief description of project: Ziply proposes to place terminal at pole performed byNWN,PGE, or utility agency 252028, place drop fom this pole to pole 251173, and place aerial drop ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer Work performed for the purpose of: at pole 251176 at customer's location • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and Location (address if available): 16060 SW 85th Ave Tidard, OR 97224 main line tap ❑ TYPE 3—Full Scale Development Work performed with land use approval which includes any of the following. • Subdivisions or Partitions APPLICANT INFORMATION • Street widening Name: Ziply Fiber- Michelle Rose • Mainline installation for sanitary sewer, storm sewer, Tigard water, and Tigard Mailing address: 6074 N Discovery Way Ste. 125 water service area City/State: Boise, ID dip: 83713 ❑ TYPE 4-Small Cell Technology Phone: 208-576-4031 [1TYPE 5—Tigard Triangle Email: Permitting@mountainitd.eomPhone: NOTE: Type 1 and 2 applications may be Contact name: Russ Wells emailed to rowpermitsOatiWrd-or.gov. Phone: 503-643-1001 Email: russell.wells@ziply.com CONTRACTOR INFORMATION ❑ Same as applicant Name: Northsky Communications CCB Number: 208747 Mailing address: 11818 SE Mill Plain Blvd Ste 410 City/State: Vancouver, WA Zip: 98684 Phone: Email: ENGINEER INFORMATION Name: Russell Wells Mailing address: 4155 SW Cedar Hills Blvd City/State: Beaverton, OR Zip: 97005 Phone: 503-643-1001 Ems: russell.wells@ziply.com ADDITIONAL INFORMATION Estimated value of workis required(if over$5,000):$ (within the public right-of-way) Is work related to a LAND USE DECISION? ❑Yes ❑No Case number: Cityof Tigard • 13125 SW Hall Blvd. Tigard,Oregon 97223 u w-xv.dgard-or.gov • 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as'Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this il�plication. Franchised or Licensed Utilities are not required to obtain the owners signature on the application. I,the applicant,certify that: • To the best of my knowledge, all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. wk frjl C.C� 165a-d- Michelle Rose 1/6/2022 Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY ZW— Case No: PF12022-0000 Permit fee: –3602ry Received by: SPV Date: 1/6/2022 Approved by: Date: Notified by: Date: � L3 2a/ City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 www..tigard-or.gov • 503-718-2421 • Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7% (less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR STAFF USE ONLY • ' STAFF USE ONLY TYPE 4: SMALL WIRELESS FACILITY TYPE 1—3: DETAILED SUBMITTAL CHECKLIST REQUIREMENTS Does applicant have a right-of-way license? ❑Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered? (check all that apply): ❑Small Cell ❑Macro ❑ Street Name How many install sites are proposed as part of this permit ❑ Site Address application? TYPE 3-Must provide 4 sets of plans(sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: ❑Public Right-of-Way ❑Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes(City,Water,Sewer,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineers Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval City of Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 3 of 4 Edge of Pavement I Ditch Stretlight ......... .r�.� • } »nt. I I I i T"PropSs SwerTiRe' � I _ 1 CU I I1 in Existing House ze I Existing 1 Ie Driveway r �1 ;I I ' al i00 i o Existing Shop i _ I Po werpole I I I 1. � i � I a 95' 1 Foe Line — � I I Fire Hydrant(FH) � I I Scale: 1"=30' � I I TYPE 1 AND TYPE 2: MINIUM SKETCH REQUIREMENTS (Put N/A if not � I I � I applicable) North arrow Property lines&dimensions Existing utilities locations (sewer,storm,water) Street&street names All existing structures Proposed work Existing curb or edge of pavement Utility&street light poles Existing S/W or D/W apron 51ope of property Trees City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwti ard-or.gov • 503-718-2421 • Page 4 of 4 CUSTOMER: ORDER# ISSUED: DUE: ADDRESS' f$y. SERVILE TME' Ali •� AS9IGNMENL' TEST: ® kHi SPECIAL NOTES' UNITS/ACCT CODES d LA a _ Sa ® REVISIONS IT- ZIPly W09119221M SW 85TH AVE NUn RT W09119n ` r>ma oN.mvwrz. RSA.Racuoals Wn yPo911Bi3Itl®M6fX Tnvmi -souvmo YNf: I:kt iM061A1t1:— t s PROJECT 51351-554207-713 W0911922 BBFTP-TIGARD-METRO-E-16060 SW 85TH AVE, PORTLAND/TIGARD OR GENERAL canslRDcnaN FROM& CONTACTS: APP: 12/20/21 MANY FACILITIES AND CABLES ARE OMITTED FOR t1EANTY. ALWAYS UTILIZE ALL PERSONAL ENGINEERING Date.12/30/2021 PPE.PROVIDE APPROVED TRAFFIC CONTROL PLAN.ALWAYS GET LOCATES BEFORE ANY AND RUSS WELLS ALL 01=K. ATTENTION HKNI VOLTAGE GYM HEAD POWER ALONG TMS ENTIRE WORK 503-643-1071 Order:PSR 3400785 AREA ANY C14ANGES OR ADDITIONS NEED TLD BE PRE-APPROVED BY TIE LOCAL EFF KEEL ENGINEER.FOLLOW ALL LOCAL MID FE"AL SAFETY LAWS URRE ALL TESTING AND 972 249 8968 Circuit D:43A2XN/724072//NWFU SAFETY EOW-CLEAN UP ANY WORM AREAS BEFORE LEAVING TO THE NEXT LOCATION, FACILITIES service:AMR EM ENSFE GRADE AID '(ROUND IS REPAIRED. ENSURE THAT ALL REQUIRED PERMITS ARE ANGELA ECHAUM A N TIUSE ALL MANNICLE PPE AND SAFETY PROCESSES 5503-643-0390 Customer End User:smanrak Ineprponded/PGE INSPECTOR Address:16060 SW 85th Ave-Portland,OR DAVE CARNLEY 971-940-9000 Exchange:TG10/51351 SPUCING/PLACING OA/CO:041/963 DAVE CARNLEY g ♦ """ 971-940-9000 Customer Desired Due Date:1/3/22 ,. •" LOCATES S811 LOON:OREGON SITE CON=MY SIMM HOURS: ••.,. RACING-2 HOURSSITE TEl NO=W3d139d32 "CNG F -!2HOURS SITE EMAIL=RAYSIMIIARFeSMARTMNNFT Q PUCINSPECTHOURS SPLICIING- 12 HQVRS -';wiMawaxe+xmae . a, Carrier:21ply Retail _ ' UNITS/ACCT CODES Project Manager;Kut Krier r O ,rny OSATN:2373880 a �' Ford,Copper Term:R&GTD T12951 =� A , 0.IF • '. �eV Cour.XD,1W3.BBGro19,l9Dx-19D3rxD,19Da.BBGTD tl ,v • ■ UNITS/PLACTFVk 19,1905-IM7.XD,1908.MM19,19D}1911•BMM19,1912•XD,1913 BBGTD uN TS/%,uCWO 19,1914.191 WBMM 19,1917.ID,1918.BBGTD 19,191319R.XD,19231925 2422.201 fur: UNKNOWN BELONG RFARRAN.E CIASIRE UG-1 SPLICING:PLACE 6 PORT 50'-1 Flber Count UNKNOWN SPLICING SPLICE FIBER-2 CW CODE I:TGADORXA UNITS/SPLICING CLU CODE 2: 2421.201 SPLICING REARRANGE CLOSURE AE-I Beaverton Facilities Reserve fiber.FC2040,761"#I+ SPLICING SPLICE FIBER-2 SPLICING PLACE 6 PORT 50'-1 OSP Work Orde,OSP WO laerired UNITS/PUCING Varasset Tkkel:5504207-713/WO911923-Fielding&Engineering 242L201 OSP please respond wHh an ECD Date ASAP'. PucE AERIAL DROP-491' CAUTION ** TGPDDPXA-160W SW 85th Ave-Portland,OR 19 Multiple Voltage power n,rner rnn vi[ MATERIALS Circuits Overhead REVISIONS locate W-32/27 at SW Avon SI&SW Hall Bhd,Spike FQ040,761-762 from the 7�nncRs Omer Rromulp 2421 201 864. I LIPID d952d1 to Me 24-0ber LIED 666841.Locate Me splice at pole 8 PORT 501-1252026 on SW.85th.Nxe a new Fport terminal at this location Splice / FC20O,761-762 from the 24-fiber into P*0#1 and PVrtX2.FC2040,762 WdI be e spare to this terminal.Ecce a drop from this terminal to Pole 251173 to this / customer to Ilse upper cabinet. Test Fiber back to TGRDORXA 54W FDF 00S0941. Pbee NIO and tum-pp,,vk,on FC2040,761. 'STOP and LOOK UP' F Fiber-Fred assignment:FC2040,761 to TERM 11%A 5,160 FDF Wk-09-41 L T I \/ ' Fiber-Distribution assign rent:N/A r / EIaH CMG[I re WNh a1W QINaTIPnF. W0911922 16060 SW 85TH AVE Wig. W0911922 `D,°Ip, ;�. U C WANmRinR, mi,zrm witil2,NPBri erwE ,.,m maw- uw i' s BBP_ arc _ Access MH 32/27 1 I II II II splice fiber 498 01.2006 OOR 04B_{._B440 IITGRD MH 32/27 XD.549-672+ TGRDORXA FC2040.673-768+ II II IIII %D,769-864 —MRD MH 33/28— X —�� �----- L--=-- -- — -- TGRD MH 735129 _ _ /______59LDUr51AEE Rn lRFAMRIOpL-TUAI ARN Nwr OR-1}7 eW 252747 C2114A26 31060 C217JB390J -------------- ZIPLY FIBER ZIPLY FIBER 720 02.2011 RBN NEW COUNT TGRDORXA FC2040,763-768+ TGRDORXA 56S1 32 XD,7-24 820 02.2011 820 02.2011 , ZIPLY FIBER RBN RBN TGRDORXA FC2040,763-768+ TGRDORXA FC2040,763-768+ "7-e+1 (TGRDORXA FC2040.781-762+) UNITS/ACCT CODES KD,9-24 X0,9-241 251176 C2113B3904 ZIPLY FIBER Place aerial drop at pole 251176 at customer$ location I �� GENERAL CDNSiRUCTCN NOTES I ^ 16060 SW 8591 Ave YANY FACILITIES AND CABLES ARE OMITTED FOR f1EAPotY.ALWAYS UTILIZE ALL PERSONAL PPE PROMOE APPROVED TRAFFIC CONTROL PLAN.ALWAYS GET LOCATES BEFORE ANY AND ALL DIGGING. ATTENTION HIGH VOLTAGE OVER HEAD POWER ALONG THIS ENTIRE WORK AREA.ANY CHANGES OR ADDITIONS NEED TO BE PRE-APPROVED BY THE LOCAL ENGINEER.FOLLOW ALL LOCAL AND FEDERAL SAFETY LAWS UTILIZE ALL TESTING AND TGRDORXA 58 3905 SAFETY EOUP.CIEM UP ANY WORK AREAS BEFORE LEAVING TO THE NEXT LOCATION, ENSURE GRADE AND GROUND IS REPAIRED.ENSURE THAT ALL REWIRED PERMITS ARE ZIPLY FIBER — A AND.UTI MANHOLE PPE ANO SAFETY PROCESSES. , b REVISIONS 6 PORT 500G TGRDOM 929802 cC}oo 251173 C2113R7039 TGRD0RXA FC2040G751_752+ ZIPLY FIBER TAG FIBER FC2040,761 AT TERMINAL !I FC2040,762 IS SPARE PLACE AERIAL DROP TO CUSTOMER MPOE TO UPPER CABINET 4# CAUTION ss I Multiple Voltage Power I - ply IIII Circuits Overhead W091192216060 SW 85TH AVE Place terminal at RAIDER Eo.Asx mAw W0911922 Pole 252026 place �j ® �� N,KeEW: Ermrarc mva,rw dropfrom this le CAUL BEFORE YOU DIL aWN(Ar, Mll5 °m liffi IW M6 X Po U11=1 RRIF'.YW12 ttb RE. e-1-1 'STOP and LOOK UP rAE 1100 MM�EIAG}_ IMG H s t0 pole 2511]3 252028 C211JB3906 �B Houes wncE REQUIRED ZIPLV FIBER tWWP- SFc - GENERAL CGNSTRUCTNIN NOTM MANY FACILITIES AND CABLES ARE OMITTED FOR CLEAIMTY.ALWAYS UTILIZE ALL PERSONAL PPE PROVIDE APPROVED TRAFFIC CONTROL PLAIN.ALWAYS GET LOCATES BEFORE ANY AND WALL gGOING.ATTENTION MOI VOLTAGE OVER HEAD POWER ALONG THIS EN7RE WORK AREA ANY CHANGES OR ADDITIONS N®TO RE PRE-APPROVED BY THE LOCAL IENGINEEA FOLLOW ALL LOCAL AND FEDERAL SAFETY LAWS.UTILIZE ALL TESTING AND SAFETY EQUIP.CLEAN LP ANY WORK AREAS BEFORE LEAVING TO THE NEXT LOCATION, EDISIIRE GRADE AND GIRDLING IS REPAIRED.ENSURE THAT ALL REQUIRED PERMITS ARE MD ON HAND.UTIUZE ALL MANHOLE PPE AND SAFETY PROCESSES. L21 90+0 µ9S24 /44880 66TA W-0 YJ0864-SM YJD49-SM 466TH SIW11 21784 FC2040:1-768+96Xd FC2040:721-768 UG2S7 W1N SW AVON ST& SW HALL BLVD. REV 02/10/11 kc TO C.O. TO MH 26 MH 2 ) 8PIqrp1 g UNITS/ACCT CODES -2 C22:1- b� 8 -SD 422:1-600+100%0+701-11 + 47%D+1798-7200 o+i FIBER COUNT GOES THROUGH MH29 TT11n-2A YG024-BM TO MNn m ca FT312:1-n tr ne:,-xAWan-EM rcoz+-W 0 nm0:,-z nwl-2A TO cc Q 31e-� - } e BD'.gNFCe:Bbl-1W1 y � IKA]:Jit-� x000+90,-1W0 i{ umule_z S§ ©O g c1E,11D,-2100 L21 MH53 uwl-z4 gg 3 t+�o— W20 ewe3 z g:S SIMTA O -PI2,Te• IS 1121_u1f'..151 i A HH a DURHAM la. rMH 28 UNITS/ACCT CODES n:,-Boo n0000+ce:,2m-,e00 ucrca,z-Om UCIE12- OiAMt MOLE � i0 AD.1.MX � R e:,0o1-,e XS12 Tow O® ®0 p 80000.ce:s01-Taw uasSlz-z 0� ° ioO�ieBOlm- O 20000«1101-18CNI umAno- uGSTM1e-24 e:I oa-,e00.ea-TPwdC1aD ucAE x-z La uHee/zWN Q CA OTeA 00 , MH29ze on o�ual,.,la H Hui a 7,/KJ✓mI p REV,/2a/ez MH 2 jp, A>R ne AIR APE REVISIONS 4 p:; ® GENERAL CONSTRUCTION NOTES: — MANY FACUWES AND CARIES ARE OMITTED FAR CIEAIBTY.ALWAYLPROCESSES ALL PERSONALL 192216060 SW 85TH AVE PRE PROVIDE APPROVED TRAFFIC CONTROL RAN.ALWAYS GET LFORE ANY AND ALL DIGGING ATIENnON HIGH VOLTAGE OVER HEAD POWER ALONGCORE WORK AREA ANY CHANGES OR ADDITIONS NEED TO BE PRE-APPROVED 'E:'-5 OCAL GG..VeA iMAPoT EeLL BEFORE You NG ENGINEER FOLLOW ALL LOCAL AND FEDERAL SAFETY LAWS.UTILIZSnIN AND 91194P EIPIULE mRSTFldB B_I_H SAFETY EQUIP.CLEAN W ANY WORK AREAS BEFORE HEAVING TO LOCATION,n POuws NOTICE RE11u1REB ENSURE GRADE ASID GRCIND IS REPAIRED.ENSURE THAT ALL RERMHS ARE waR xuSBILxHESJOIT II�ImeiWrm,M HAN M AND TY S. JfRIE%WIS2U RE AmAY DSTRCT.- PIG 5 5 X - Single Flagger Operation m i for Low Volumes �\ A I (Optional) O a. (ADT�400) �I��J .d• � BE ONE LANE `G m I � PREPARED e • • c O STOP ROAD r,• 4- AHUD iS I —. . . .� — • ROAD O • own •• ♦ WORK 8 0 8 ^ KeK• •N / AHEAD ------ I11 S 1 mile T1 I' rtlett. 4 d —• • • r• • • — — — 10 • • to • • 7 (G Bulbr / Protection Vehicle ROAD / • wl TMA(both Optional) WORK See Chapter 4 O Cf AHEAD BIL ft] ONE LANE ROA° TO STOP ARE Two Flagger Operation 3 r G AHEAD a ro m (Optional) O n