Permit lib
BACKFLOW -EXISTING _�REMOVED
PREVENTER REPORT X REP R REPLACED
REPAIRED OLD SIN:
PROPERTY NAME DR Horton Serenus Lot 10 PHONE
CONTACT NAME PHONE
MAILING ADDRESS 14582 SW 78th Ave
cm Tigard STATE OR zip 97224
PREVENTER ADDRESS 14582 SW 78th Ave Tigard, OR 97224
WATER SUPPLIER City of Tigard, Oregon sERLiL# HF 57256
LOCATION NW corner house
MAKE Febco MODEL 850 SIZE 3/4"
TYPE RP n RPDA n RPDA-II (> DC n DCDA ❑ ) A_II n PVD LA SVB n AVB n AG
HAZARD PROTECTED n PREMISES ISOLATION N IRRIGATION 1I FIRE SYSTEM 1.1 BOILER OTHER
APPROVED: IM ASSEMBLYcgi INSTALLATION 1M ORIPNTATION n AIROAP PIPE SIZE in P")nan`'
a�� roN in
REDUCED PRESSURE ASSEMBLY PVRA/SVBA INITIAL TEST
DOUBLE CHECK AIR INLET CHECK VALVE PASSED X
CHECK 111 CHECK Nl TYPE 11 n OPENEDAT-. PMF,SSDROP:
PRESS TIGHT fVl FAILED n
DROP: p-i
INITIAL MIN 5PSID 2.2
TEST RELIEF VALVE "RAKED MINI man MIN I PSID MIN I MD DATE 09-10-22
RESULTS oration Kr: _ p- OPENED
MIN 2PSID CHECK#2 FIF1.1.Y n'v' - FAILED SYSTEM PSI 105
RELIEF VALVE: TIGHT NI DID NOT n DETECTOR METER
PASSED n FAO.RD n 2.0 OPEN f , READING:
LEAKED ri MIN I PSID
NOTES
REPAIRS
PARTS
REDUCED PRESSURE ASSEMBLY PYBA/SVBA TEST
CHECK#1 DOUBLE CHECK AFTER REPAIRS
PRESS
DROP: CHECK#1 TYPE 11 n AIR INLET CHECK VALVE
REPAIR MIN s PAID TIGHT n onna u AT: PRESS DROP:
RESULTS RELIEF VA1.Vr. _ DATE
OMR°AR CHECK 12 WE I ISM MIN I PSID MIN I PAR)
RRIdaFVALVa MIN2PSID TIGHT OPENED nowt PASSED L
PAWED n FAM) n MINI MD
GAUGE SIN 04141250 MAKRJMODEL Mid-west Instruments 845 CALIBRATION DATE 11-12-2021
In completing and submitting this test report,the tester certifies that the assembly was tested and maintained in accordance with all applicable
rules,laws,codes and rgulations of the slate and water system using approved testing equipment and approved testing procedures.
INITIAL TEST TEST AFTER REPAIRS
066108
TE,STERSIGNATURE TESTER SIGNATURE TESTER CERT#
Jordan A 503-849-0237
TESTER NAME(PRINTED) IASI nit NAME(PRINTFM) PHONE#
2153 Molalla Rd Woodburn, OR 97071 Jordan@ablandscapes.net
TESTER ADDRESS TESTER ADDRESS EMAIL
Ashland Brothers Backflow Testing, Repair&Install
COMPANY NA ME COMPANY NAME WATER RESTORED?
i IFOUND OFF,LEFT OFF
REPORT RECEIVED BY(REPRESENTATIVE OP OWNER) REPORT RRCJIIVND BY(REPRESENTATIVE OF OWNER)
CITY OF TIGARD MASTER PERMIT
COMMUNITY DEVELOPMENT Permit#: MST2021-00487
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/18/2022
Parcel: 2S112BD01000
Jurisdiction: Tigard
Site address: 14582 SW 78TH AVE
Subdivision: Serenus Subdivision Lot:
Project: Serenus, Lot 10
Project Description: New detached dwelling
BUILDING
Floor Areas Required Setbacks Required
Stories: 2 Bedrooms: 4 First: 913 sf Basement: 0 sf Left: 5 Parking Spaces: 0
Height: 21.5 Bathrooms: 3 Second: 1338 sf Garage: 407 sf Front 15 Smoke
Yes
Dwelling Units: 1 Third: 0 sf Right: 5 Detectors:
Total: 2251 sf Value: $315,421.90 Rear: 15
PLUMBING
Sinks. 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0
Lavatories: 4 Dishwashers: 1 Floor Drains, 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100
Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1
Drywell-Trench Drain: 0 Other Fixtures 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 5 Clothes Dryers: 1
Natural Gas Heat Pump: N Hoods: 1 Other Units: 0
Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets 3
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'I 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+ampivolt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Y
Other: N Other Description: Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
NEW SF VB R-3 2251
Owner: Contractor:
BLUE PALOUSE PROPERTIES LLC DR HORTON INC PORTLAND Required Items and Reports(Conditions)
14630 SW 79TH AVE 4380 SW MACADAM AVE SUITE 100 1 Ersn Cntrl 503-639-4175
TIGARD,OR 97224 PORTLAND,OR 97239
PHONE. PHONE: 503-222-4151
FAX: 503-222-1304
Total Fees: $38,806.74
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
o9-nn1_mil n rhrni inh nal o9-nn1 anon Vnn mw nhrzin rnnv of that nr dirorf nl.efinne fn nl R(11 91)10A7 nr 1 Ann'319''MA
Issued By: HoL1 y V ti De Wee Permittee Signature: Ow Ap .1Ji'.rt L. -v.
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Application ► _ 1 2 2
Residential FOR OFFICE USE ONLY
City of Tigard RECEIVED DReactee/iBve d: / q2021 - a Permit No.: MSI G I-00/ J
IN . 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Noti d/Method: n
Phone: 503.718.2439 Fax: 503.598.1960 N O V 0 2 2021 Date/By: I 2 Other Permit: R2(7L1-(�Zg9
I I(,A l:a Inspection Line: 503.639.4175 4f Date Ready/By: /�' '7u� ev
PP® See Page 2 for
Supplemental Information
Internet: www.tigard-or.gov CITY OF TIGARD
TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING
n New construction ❑ Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application. f°
2?10 1-and 2-family dwelling ElCommercial/industrial Valuation: ,p, �� 3'�j� 4,(�, r
ElAccessory building 0 Multi-family Number of bedrooms:4
❑ Master builder ❑Other: Number of bathroomsf3
JOB SITE INFORMATION AND LOCATION Total number of floors:2 Z4 S$
Job site address:14582 SW 78TH AVE New dwelling area: 225 square feet 133$
City/State/ZIP: Garage/carport area: 407 square feet 0113
Suite/bldg./apt.no.: Project name: Serenus Covered area square feet
Cross street/directions to job site: Deck ea:24 square feet
Others e area square feet Landing
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Serenus I Lot no.:10 Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
NSPR Valuation: $
Existing building area: square feet
New building area: square feet
❑ PROPERTY OWNER, ❑ TENANT Number of stories:2
Name:DR Horton Type of construction:
Address: 4380 SW Macadam Ave Ste 200 Occupancy groups:
City/State/ZIP: Portland OR 97239 Existing:
Phone:(503 ) 222-4151 Fax:( ) New:
j ❑ APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES*
Business name: DR Horton (Please refer ro fee sct�edute)
Structural plan review fee(or deposit): r,1•3y
Contact name: Emerald Weeks
FLS plan review fee(if applicable):
Address: 4380 SW Macadam Ave Ste 200
City/State/ZIP: Portland OR 97239 Total fees due upon application:
Phone:( 503 ) 222-4151 Fax: :( ) Amount received:
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
E-mail: esweeks@drhorton.com drhorton.com .,
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name: DR Morton Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 4380 SW Macadam Ave Ste 200 Solar Installation Specialty Code checklist.
City/State/ZIP: Portland OR 97239 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( 503 ) 222-4151 Fax:( ) o
State surcharge(I 2/o of permit fee): $21.60
CCB lie.: 13059 c �y
'-t 3&�0�/��//' , it6122 Total fee due upon application: $201.60
Authorized signature: Cj12,IZ/J:000G�i IN This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name: Emerald Weeks Date: 6/3/2021 *Fee methodology set by Tri-County Building Industry
Service Board.
L:\Building\Permits\BUP-RESPennitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB)
r'
Building Permit Application Checklist
One- and Two-Family Dwelling FOR OFFICE USE ONLY
City of Tigard Received permit Nu.
g Date/By:
■ 13125 SW Hall Blvd.,Tigard,OR 97223 Associated permits:
Phone: 503.718.2439 Fax: 503.598.1960
0 Electrical ❑ Plumbing0 Mechanical
24-Hour Inspection Line: 503.639.4175
TIGARD internet: www.tigard-or.gov ❑ Other.
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A
1 Land use actions completed. See jurisdiction criteria for concurrent reviews. x i ❑ ❑ ❑
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. x❑ 0 0
3 Verification of approved plat/lot. x❑ ❑ 0
4 Fire district approval required. Name of district: . x❑ 0 ❑
5 Septic system permit or authorization for remodel. Existing system capacity _ D ❑ 0
6 Sewer permit. 0
x 0 ❑ ID7 Water district approval. x❑ 0 ❑
8 Soils report. Must carry original applicable stamp and signature on file or with application.
9 Erosion control ❑plan ❑pen-nit required. Include drainage-way protection,silt fence design and location of catch- x❑ ❑ ❑
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state x❑ 0 0
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if
copyright violations exist.
11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if x❑ ❑ 0
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft. intervals);location of easements
and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction
indicator; lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size CI ❑ ❑
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, x❑ ❑ ❑
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- x❑ ❑ ❑
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. x❑ ❑ ❑
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendums showing foundation elevations with cross references are acceptable. x❑ ❑ ❑
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non-
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing x❑ ❑ ❑
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered x❑ ❑ ❑
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists x❑ ❑ ❑
over 10 feet long and/or any beam/joist carrying a non-uniform load. x❑ ❑ ❑
20 Manufactured floor/roof truss design details.
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ,❑ ❑ ❑
for four or more appliances. ❑ ❑ ❑
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or x
architect licensed in Ore_on and shall be shown to be a'•licable to the .ro'ect under review.
JURISDICTIONAL SPECIFICS
23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ❑ 0 ❑
24 Two(2)sets each are required for Items 16, 19,20 and 22 above.
25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not he accepted. ❑ ❑ ❑
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ O ❑❑
27 "Drawn to scale"indicates standard architect or engineer scale.
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ ❑
Street Tree List.
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑
and protection measures must be drawn to scale and must include the project arhorist's signature of approval. ❑ ❑ ❑
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions,
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9, 1995.
l:\Building\Pennits\BUP-RESPennitApp.doc 02/24/2011 440-4613T(1 I/02/COM/WEB)
Mechanical Permit ApplicationII ECElVED
Received S 70^1
City of Tigard Permit No. L 21 49
`J � Date/By: r Q
1 ' 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503.718.2439 NOV 02 202 Plan Review Other Permit:
Date/By:
i 1 t.A R I inspection Line: 503.639.4175 CITY OF TIGARD Date Ready/By: Juris BI See Page 2 for
w Internet: ww.tigard-or.gov Notified/Method: Supplemental Information
BUILDING DIVISION
TYPE OF WORK COMMERCIAL FEE*SCHEDULE—USE CHECKLIST
®New construction 0 Addition/alteration/replacement Mechanical permit fees'are based on the value of the work
performed.Indicate the value(rounded to the nearest dollar)of all
❑ Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit.
CATEGORY OF CONSTRUCTION Value:$
RESIDENTIAL EQUIPMENT/SYSTEMS FEES*
❑ 1-and 2-family dwelling 0 Commercial/industrial ❑Accessory building
For special information use checklist.
❑ Multi-family 0 Master builder 0 Other: Description Qty.. Ea. Total
JOB SITE INFORMATION AND LOCATION Heating/cooling:
Job site address: 14582 SW 78TH AVE Air conditioning 46.75 ,
Furnace 100,000 BTU(ducts/vents) 46.75
City/State/ZIP: Furnace 100,000+BTU(ducts/vents) . 1 54.91
Suite/bldg./apt.no.: Project name: Serenus Heat pump 61.06 ,
Duct work I 23.32
Cross street/directions to job site:
Hydronic hot water system 23.32
Residential boiler(radiator or
hydronic) 23.32
Unit heaters(fuel-type,not electric),
in-wall,in-duct,suspended,etc. 46.75
Flue/vent for any of above 23.32
Subdivision: Serenus Lot no.: 1 0 Other: 23.32
Tax map/parcel no.: Other fuel appliances:
Water heater 23.32
DESCRIPTION OF WORK Gas fireplace/insert 33.39
NSFR Flue vent for water heater or gas
fireplace 23.32
Log lighter(gas) 23.32
Wood/pellet stove 33.39
Wood fireplace/insert 23.32
Chimney/liner/flue/vent 23.32
0 PROPERTY OWNER 0 TENANT Other: 23.32
Environmental exhaust and ventilation:
Name: DR Horton
Range hood/other kitchen
Address: 4380 SW Macadam Ave Ste 200 equipment 1 33.39
Clothes dryer exhaust 1 33.39
City/State/ZIP: Portland OR 97239 Single-duct exhaust(bathrooms,
4
Phone:( 503 ) 222-4151 Fax ( ) toilet compartments,utility rooms) 23.32
Attic/crawlspace fans 23.32
0 APPLICANT 0 CONTACT PERSON Other: 23.32
Business name: DR Horton
Fuel piping:
$14.15 for first four;S4.03 for each additional
Contact name: Emerald Weeks
Furnace,etc.
Address: 4380 SW Macadam Ave Ste 200 Gas heat pump
City/State/ZIP: Portland OR 97239 Walllsuspendedlunit heater
Water heater 1
Phone:( 503 ) 222-4151 Fax: :( ) Fireplace
E-mail: esweeks@drhorton.com Range 1
CONTRACTOR Barbecue
Clothes dryer(gas)
Business name: Development Northwest Inc.,dba Wolcott HVAC Other:
Address: 1075 W Historic Columbia River Hwy MECHANICAL PERMIT FEES*
Subtotal
City/State/ZIP: Troutdale,OR,97060 Minimum permit fee($90.00)
Phone:( 503 ) 667-1781 Fax:( 503 ) 667-9891 Plan review(25%of permit fee)
State surcharge(12%of permit fee)
CCB lic.: 112220 TOTAL PERMIT FEE
This permit application expires if a permit is not obtained within 180
days after it has been accepted as complete.
Authorized signature: /4,Z 7;7„,...1,74.„/".\-_
• Fee methodology set by Tri-County Building Industry Service Board
Print name: Andrew Darland Date: to/21/21
t\Building\Permns\MEC_Per mtApy_082520.doc 4404617T(I I/02/COM/WEB)
Electrical Permit Application RECEIVED FOR OFFICE USE ONLY
City of Tigard Date/By: _
• 13125 SW Hall Blvd.,Tigard,OR 97223eceived
NOVN�V ®� 2021 Plan Review Permit Sj2b 2(-004$?
■ Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit#:
Inspection Line: 503.639.4175 CITY OF TIGARD Ready Date/By: Juris: ® See Page 2 for
T I G A RI) Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: Supplemental information
TYPE OF WORK PLAN REVIEW
El New construction 0 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked):
❑Service or feeder 400 amps or more 0 Building over three stories.
❑ Demolition ❑Other: where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
less to ground,or exceeds 14,000 ❑Commercial-use agricultural
0 1-and 2-family dwelling 0 Commercial/industrial ❑ Accessory building
amps for all other installations. buildings.
0 Multi-family ❑Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived
0 Addition of new motor load of system.
Job#: Job site address:14582 SW 78TH AVE 10011P or more. ❑"A `E","1-2", 1-s ,
0 Six or more residential units. occupancy.
City/State/ZIP:
0 Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: Project name: Serenus 0 Hazardous locations. ❑Supply voltage for more than
0 Service or feeder 600 amps or more, 600 volts nominal.
Cross street/directions to job site: :,v rti. w--'-. -,• „;, ,1 "' ' ``
Description Qty. Each Total
New residential single-or multi-family dwelling unit.
Subdivision: Serenus Lot#:10 Includes attached garage.
1,000 sq.ft.or less 1 168.54 4
Tax map/parcel#: Ea.add'I 500 sq.ft.or portion 3 33.92 1
DESCRIPTION OF WORK Limited energy,residential
NSFR
(with above sq.IL) 75.00
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
Renewable Energy ❑ See Page 2
❑ PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation
Name: DR Horton 200 amps or less 100.70 2
Address: 4380 SW Macadam Ave Ste 200 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP: Portland OR 97239 601 amps to 1,000 amps 301.04 2
Phone:(503 ) 222-4151 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: esweeks r drhorton.com relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
Branch circuits—new,alteration,or extension,per panel
..,.. - ,- " n s r 4'':_«,:. ., 'q- . -,, ,',','" - A.Fee for branch circuits with
Business name: DR Horton above service or feeder fee, 7.42 2
each branch circuit
Contact name:Emerald Weeks B.Fee for branch circuits without
Address: 4380 SW Macadam Ave Ste 200 service or feeder fee,first 56.18 2
branch circuit
City/State/ZIP: Portland OR 97239 Each add'I blanch circuit 7.42 2
222-4151Miscellaneous(service or feeder not included)
Phone:( 503 ) Fax: : ( ) Each manufactured or modular 67.84 2
dwelling,service and/or feeder
Email: esweeks rt drhorton.com
Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:Garner Electric Co Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy El See Page 2 2
Address:2890 SE Brookwood Ave. panel,alteration,or extension.
City/State/ZIP: HiliSboro, OR 97123 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:(503-648-4552 Fax:( ) Investigation(1 hr min) 90.00/hr
Email: Industrial plant(1 hr min) 78.18/hr
permits@garnerelectrlc.com inspections f'or which no fee is
CCB Lie.: 121159 Suprv. specifically listed('A hr min) 90.00/hr
Electrical Lic.: 4- 05C Lic.:3707-S
ELECTRICAL PERMIT FEES
Suprv. Electrician signature,required: Subtotal:
Print name: Charles Garner Date: ❑Plan Review Required(25%of permit tee):
/�� ,'W J State surcharge(12%of pennit fee):
Authorized signature:�fyLe2CLG ? TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name: Emerald Weeks Date: 6/3/2021 days after it has been accepted as complete.
* Number of inspections allowed per permit.
i:kBuilding\PermitsELC_PermitApp_ELR_ERE.doc Rev06.,17/2015 440-4615T(II/05/COM/WEB
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
;
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Description I Qty. I Each I Total
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
5 kva or less 100.70 2
Check Type of Work Involved:
5.01 to 15 kva 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
n B• urglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
n G• arage Door Opener* >100 kva(fee in accordance 552.26
with OAR 918-309-0040)
n H• eating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed(1/2hr min)
COMMERCIAL WORK ONLY: ' '
Subtotal(Enter on Page 1):
Fee for each commercial system: $75.00 * Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
• Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
in Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems: _
*No licenses are required. Licenses are required for all
other installations
I rBuilding\Permits'ELC_PermitApp_ELR_ERE.doc Res 06,17 2015
Plumbing Permit Application
Building Fixtures RECEIVE , FOR OFFICE USE ONLY
• City of Tigard Received Permit No.: 1.1612024-001{-87
.IN ' 13125 SW Hall Blvd.,Tigard,OR 97223 NOV ®�,, 2021 Date/By:
Plan Review
Phone: 503.718.2439 Fax: 503.598.1960 Other Permit No.:
CITY OF TIGARD Date/By:
Inspection Line: 503.639.4175 Date Ready/By: Juris: la See Page 2 for
T I GAIt D Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: Supplemental Information
TYPE OF WORK FEE* SCHEDULE
Q New construction 0 Demolition For special information use checklist.
Description ] Qty. 1 Ea. I Total
❑Addition/alteration/replacement 0 Other: New I-2-family dwellings(includes 100 ft.for each utility connection)
CATEGORY OF CONSTRUCTION SFR(1)bath 312.70
❑ 1-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 437.78
SFR(3)bath 1 500.32
❑Accessory building 0 Multi-family
Each additional bath/kitchen 25.02
❑Master builder CI Other: Fire sprinkler( sq.ft.) Page 2
JOB SITE INFORMATION AND LOCATION Site utilities:
Job site address:14582 SW 78TH AVE Catch basin or area drain 18.76
City/State/ZIP: Drywell,leach line,or trench drain 18.76
Footing drain(no.linear 11.:_) Page 2
Suite/bldg./apt.no.: I Project name: Serenus Manufactured home utilities 50.03
Cross street/directions to job site: Manholes 18.76
Rain drain connector 18.76
Sanitary sewer(no.linear ft.:_) Page 2
Stonn sewer(no.linear ft.:_) Page 2
Water service(no.linear ft.:_) Page 2
Subdivision: Serenus I Lot no.:10 Fixture or item:
Tax map/parcel no.: Backtlow preventer 31.27
DESCRIPTION OF WORK Backwater valve 12.51
Clothes washer 1 25.02
NSF R
Dishwasher 1 25.02
Drinking fountain 25.02
Ejectors/sump 25.02
❑ PROPERTY OWNER I 0 TENANT Expansion tank 12.51
Fixture/sewer cap 25.02
Name: DR Horton
Address:
4380 SW Macadam Ave Ste 200 Floor drain/floor sink/hub 25.02
Garbage disposal 25.02
City/State/ZIP: Portland OR 97239 Hose bib 2 25.02
Phone:( 503 ) 222-4151 Fax:( ) Ice maker 12.51
❑ APPLICANT 0 CONTACT PERSON Interceptor/grease trap 25.02
Business name: DR Morton Medical gas(value:$ ) Page 2
Contact name:
Emerald Weeks Primer 12.51
Roof drain(commercial) 12.51
Address: 4380 SW Macadam Ave Ste 200
Sink/basin/lavatory 4 25.02
City/State/ZIP: Portland,OR 97239 Solar units(potable water) 62.54
Phone:( 503 ) 222-4151 Fax: :( ) Tub/shower/shower pan 2 12.51
Urinal 25.02
E-mail: esweeks@drhorton.com 3 25.02
Water closet
CONTRACTOR
Water heater 1 37.52
Business name: Alliance Plumbing,LLC Water piping/DWV 56.29
Address: 146 W Historic Columbia River Hwy Other: 25.02
City/State/ZIP: Troutdale,OR 97060 Subtotal
Phone:( 503)492-3490 Fax:( 503 ) 912-6438 Minimum permit fee: $72.50
Plan review (25%of permit fee)
CCB Lie.: 184601 Plumbing Lic.no.: PB732 State surcharge(12%of permit fee)
Authorized signature: t t- 4- TOTAL PERMIT FEE
Print name: Gavin Thomes Date: This permit application expires if a permit is not obtained within 180 days
7.01.2021 after it has been accepted as complete.
"Fee methodology set by Tri-County Building Industry Service Board.
L,Building,Permits PLMU-PermitApp.doc I 0,01/09 440-4616T(IO/02(COM'WEB)
l
Plumbing Permit Application - City of Tigard
Page 2 - Supplemental Information
Fee Schedule: Residential Fire Suppression Systems:
Site Utilities Qty. Fee(ea) Total Square Footage: Permit Fee:
Footing drain- I" 100' 50.03 0 to 2,000 $121.90
2,001 to 3,600 $169.69
Footing drain-each additional 100' 37.52 3,601 to 7,200 $233.20
Sewer-1st 100' 62.54 7,201 and greater $327.54
Sewer-each additional 100' 37.52
Water Service-1st 100' 62.54 Medical Gas Systems:
Water Service-each additional 100' 37.52 Valuation: Permit Fee:
Storm&Rain Drain-1st 100' 62.54 $1.00 to$5,000.00 Minimum fee$72.50
Storm&Rain Drain-each additional 100' 37.52 $5,001.00 to$10,000.00 $72.50 for the first$5,000.00 and$1.52 for
Qty. Fee(ea) Total each additional$100.00 or fraction thereof,to
Other Inspections or Fees and including$10,000.00.
Inspection of existing plumbing or for $10,001.00 to$25,000.00 $148.50 for the first$10,000.00 and$1.54 for
which no fee is specifically indicated 90.00/hr each additional$100.00 or fraction thereof,to
(minimum charge-1/2 hour) and including$25,000.00.
Inspections outside of normal business 90.00/hr $25,001.00 to$50,000.00 $379.50 for the first$25,000.00 and$1.45 for
hours(minimum charge-2 hours) each additional$100.00 or fraction thereof,to
Reinspection Fees 90.00/hr and including$50,000.00.
Additional plan review for revisions 90.00/hr $50,001.00 and up $742.00 for the first$50,000.00 and$1.20 for
each additional$100.00 or fraction thereof.
(minimum charge-1/2 hour)
Subtotal:
Commercial Fixture Work:
Are you capping,adding or replacing fixtures? If"yes",
please indicate work performed by fixture. Failure to
accurately report fixtures could result in increased sewer fees*. Plan Review for Plumbing Installations
Quantity by Fixture Type Plan review is required for any of the following.
Fixture Type for Replace/ Please check all that apply.
Work Performed: Capped Added Relocate
❑ Any new commercial building with water service 2"and
Baptistry/Font greater,except systems designed and stamped by licensed
Bath: -Tub/Shower engineer.
-Jacuzzi/Whirlpool ❑ New exterior plumbing site utilities for any complex structure
Car Wash: -Each Stall as defined in OAR918-780-0040.
-Drive Thna ❑ Medical gas and vacuum systems for health care facilities.
Cuspidor/Water Aspirator
0 Any multipurpose fire sprinkler system.
Dishwasher: -Commercial
- omic ❑ Any complex structure as defined in OAR918-780-0040.
Drinking Fountain Submit 2 sets of plans with any of the above.
Eye Wash
Floor Drain/sink: -2"
3•> Isometric or Riser Diagram
4" ❑ Isometric or riser diagram is required for new buildings
-Car Wash Drain that meet the qualifications above.
Garbage -Domestic non-food
Disposal: -Domestic food related
-Commercial food related
-Industrial food related Comments regarding fixture work:
Ice Mach./Refrig.Drains
Oil Separator(Gas Station)
Rec.Vehicle Dump Station
Shower: -Gang
-Stall
Sink: -Lav/Bar non-food related
-Bradley
-Com/Serv/Util food related
-Service *Note: If the fixture work under this permit results in an
Swimming Pool Filter increase of sewer EDUs,a sewer permit will be issued and
Washer-Clothes fees assessed for the sewer increase must be paid before the
Water Extractor plumbing permit can be issued.
Water Closet-Toilet
Urinal
Other Fixtures:
1:\Building\Pennits\PLMF_PetmitApp.doc 08/04/2011 2
City of Tigard
COMMUNITY DEVELOPMENT DEPARTMENT
T,GRD Building Permit Review — Residential
Building Permit #: 1,4 ST ZQ j( OO Li-g7
Site Address: 14582 SW 78th Ave
Project Name: Serenus Subdivision Lot #: 10
Planning Review
Proposal: New detached dwelling
EN Verify address/suite#active in Accela. EI In River Terrace: CR No ❑ Yes,River Terrace Review Addendum
Site Plan Elements: feRErosion Control
3 copies of site plan on 8-1/2"x 11"or 11 x 17"paper l Retained trees with drip line and tree protection measures
brawn to scale(standard architect or engineer scale) lig Footprint of new structure(including decks)and FFE
CiilNorth arrow (Utility locations&easements(required for new and additions)
Site address,project or subdivision name and lot number L Sidewalk/driveway approach
CApplicant information(name and phone number) tic s}'stems
IXLot dimensions and building setback dimensions IXStreet tree size,type and location
be demolished el Street names
�Ex3Bt•nng-xr MCorner elevations(2'contours if more than 4'differential)
DiLot area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? 1EYes No
impervious area(applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown? ❑Yes NNo
® Clean Water Services—Service Provider Letter(lot platted prior to 9/10/1995):
Required: ❑ Yes,applicant was notified Di No Received: ❑ Yes ❑ No
® Water Meter Fixture Unit Worksheet—Additions,Remodels and ADUs
Required: ❑ Yes,applicant was notified It No Received: ❑ Yes ❑ No
® SDC Exemption for ADU applied for: ❑ Yes N No Received: ❑ Yes ❑ No
Xi Public Facilities Improvement(PFI) Permit:
Required: ❑ Yes,applicant was notified N No Applied For: ❑ Yes ❑ No,stop intake
® Land Use Case#: SUB2020-00001 Ii Zoning: R-12
® Required Setbacks: Front: 15 Rear: 15 Side: 5 Street Side: 10 Garage: 20
® Building Height: Max. Height: 35' Actual Height: 21.5'
® Landscape Area: 20 % EX Lot Coverage Max: 80
Entrance Di Set back no more than 8'from street-facing wall ❑ Parallel to street or offset 45 degrees or less
Windows Minimum 12%of area of all street-facing facades
Garage a Garage door is behind widest street-facing wall IX Yes ❑ No,one of the following is met:
❑ Door extends no more than 5'from wall and there is a covered porch extending beyond garage.
❑ Door extends no more than 5'from wall and there is a 12 sq ft.window above garage on 2nd floor.
a Garage door width is ❑ 12'or less ❑ 50%or less of facade Ia 60%or less and includes 7 of following:
El Covered porch ❑ Recessed entrance 1%I Wall offset NE 1'Roof cave NI Roof offset
❑ Fire shingles DZ Lap Siding ❑ Roof pitch DI Gable,hip,or gambrel roof ❑ Dormer
Accent siding ❑ Window trim ❑ Window recess ❑ Window projection ❑ Balcony
Pg Visual Clearance ►;1 Urban Forestry Plan
XI Sensitive Lands: ❑ Yes IN No Type:
❑ Conditions met prior to issuance of building permit
Notes:at Approved By Planning: Date: ((/ Q'V /2----eZt
Revisions (after Building Submittal only) Reviewer Date
Revision 1: ❑ Approved ❑ Not Approved
Revision 2: ❑ Approved ❑ Not Approved
I:\Building\Forms\BldgPermitRvw_RES_122419.docx
.
Building Permit Submittal
Original Submittal Date: 02/02/
Site Plans: # 3
Building Plans: # 3
Building Permit#: fir-Enter building permit#above.
Workflow Routing: Ca'Planning p-Engineering [Permit Coordinator [Building 1
Workflow Sign-off: CT Sign-off for Planning(include notes from planning review)
Route Application Documents: [l-Engineering: (1) copy of permit application,(1) site plan,(1)building plan and
egriginal plan review routing form.
Building: original permit application,site plans,building plans,engineer and
beam calculations and trust details,if applicable,etc.
Notes: /
By Permit Technician: . ke Date: 1VDcj/ZeZI
r
Engineering Review
[2` Slope at building pad: L°la
Lam/Conditions"Met"prior to issuance of building permit
EKEasements (encroachments) per engineering conditions of approval and plat
Water Quality/Quantity Facility:
Assess Water Quality Fee in-lieu: ❑ Yes VNo
Assess Water Quantity Fee in-lieu: ❑ Yes ['No
LIDA Facility on lot: ❑ Yes L'No
[gVFinal Plat Recorded:
❑ NOT Approved by Engineering: Date:
Notes:
44/ Approved by Engineering: G�f`rz ,/-i'Zc-,e-1.7 Date: //Je z/e. ?/
Revisions (after Building Submittal only) Reviewer Date
Revision 1: ❑ Approved ❑ Not Approved
Revision 2: ❑ Approved ❑ Not Approved
Permit Coordinator Review
Conditions"Met"prior to issuance of building permit
❑ Approved, NOT Released: Date:
Notes:
Revisions (after Building Submittal only)
Revision Notice 1: Date Sent to Applicant:
Revision Notice 2: Date Sent to Applicant:
SDC Exemption: ❑ Received 7 Does not apply
Zi SDC Fees Entered: Wash Co Trans Dev Tax: ,� Yes ❑ N/A
Tigard Trans SDC: gr Yes ❑ N/A
Parks SDC: ,e Yes ❑ N/A
LIDA ❑ Yes N/A
OK to Issue Permit
Approved by Permit Coordinator: t\ f' Date: ((0j2/I/021
I:1Building\Forms\BldgPermitRvw_RES_122419.docx