Report i OFFICE COPY 7 EIVE[ litus SubmittaDTQP1.o 5-24-16 DTQP k.;ITY OF TIGARD Fan Powered Terminal, Parallel Flow 3UILDING DIVISION Direct Digital Control, Pressure Independent '-f t& 2/- cicz/ . /02Z0 SW (, 4'5ude ) 5q5_ B 3 3/8 N 20 H 12 ,,_ oo . o o 0 61/4 00 D o A i�� linkni: p yl II T) Primary Air Inlet with Multipoint Center Averaging `G • w Sensor r_L==2_r— "_ c immim.../1 4 . 4 FIG L — 7 -®' Induced Air 2- ', :-L.J _ , t Inlet 1 1 1/4 E - L - 1 J t " Left hand unit,top view shown.All dimensions are in inches. Right hand units are built as a mirror image. Inlets,discharge,and control enclosure are opposite of the drawing above. Unit Size Inlet Size A B C D E F G H J K L W N Filter Size Oil . ---,.----4.6 6 5 7/8 2 7/8 8 6 7 7/8 2 7/8 2,3 10 7 9 7/8 4 7/8 12 8 8 9/18 16 3/4 117�/e 14 1/2 14 3 1/2 17 1/8 11 2 1/8 40 7/8 36 1/8 4 7/a 19 x 17 8 6 7 /8 2 /8 10 7 9 7/8 4 7/8 4 12 8 11 7/8 4 7/8 14 10 137/8 67/8 10 7 9 7/8 4 7/8 12 8 11 7/8 4 7/8 5 14 10 13 7/8 6 7/8 16 11 10 1/16 24 1/2 15 7/a 17 1/2 16 1/2 9 1/2 20 1/8 14 1/2 3 1/8 46 7/8 48 1/8 6 7/8 27 x 20 12 8 11 7/8 4 7/8 6 14 10 13 7/8 6 7/8 16 11 15 7/8 67/8 Motor Amperage Ratings Accessories (Optional) Unit Motor 120/1/60 208/240/1/60 277/1/60 Check[FI if provided. Size hp FLA FLA FLA `11E Induced Air Filter, 1"thick,disposable construction type '—'-40-2 1/6 3.6 1.5 "'-*1.3 ❑ Fan disconnect switch(not available on units 3 1/4 5.3 2.6 2.2 with optional electric coils.) 4 1/3 7.8 3.2 2.9 �J 5 1/3 9.2 3.3 3.2 Fibre Free Liner El 1''Fiberglass Liner 6 3/4 12.3 6.3 5.4 0 SteriLoc Liner ❑ 1"EcoShield Liner I 0 0 %"EcoShield Liner ❑ 1"EcoShield Liner(Foil Face) FLA=Full Load Amperage, as tested in accordance with UL 1995 0 ,^EcoShield Liner(Foil Face) ❑ 1"Fibre Free Liner All fan motors are single phase,same voltage as electric coil (when 0 1/2"Fibre Free Liner --""*:1 Hanger Brackets ii supplied), with exception that 277 V motors are used with 480V, 3 UltraLoc Liner phase coils(4 wire wye). 1--1 ❑ Cam Latch for Access Door 0 Fan unit fusing DTQP-3.0 5-24-16 Electric Coil Section ❑ Optional SCR Controlled Electric Heater ❑ Optional Lynergy Controlled Electric Heater Standard Features • Single side access to low voltage, 31 - high voltage,and electric heater • controls. .. e .. • Automatic reset thermal cutouts,one o 0 o 0 a 0 0 per element . c • Single point electrical connection for ' • Ir . tnt' ' ,< entire unit • nr1r-iLt-� Heater Rack • Positive pressure flow switch rrli ii iii,y ccess Cover • Flanged duct connection W • Coil is installed at discharge of unit. • Transformer Options t Ih� 1"Typ. ❑ Fuse Block •• ❑ Disconnect switch,door interlock type • R ❑ Manual reset cutout EJ D• ust tight construction J J-' 'I__J S Nri ._ ❑ M• ercury contactors r • • 4711` • • U Supply Voltage 94 s T 208V, 1 ph,60Hz 240V,1 ph,60Hz El 277V,1 ph,60Hz Unit Size U R S T ❑ 208V,3 ph,60Hz _�480V,3 ph,60Hz(4 wire wye only) 2r 3,4 3 1/2 14 11 2 1/8 5,6 9 1/2 16 1/2 14 1/2 3 1/8 3KW, 1-Stage R and S are inside dimensions. -40011 General Description • Heavy steel casing,with leak • Adjustable SCR fan speed control • Pressure independent primary resistant construction. with minimum voltage stop. flow control. • Dual density insulation,coated to • Bottom access panels can be • Single point electrical prevent air erosion, meet removed for service. connections. requirements of NFPA 90A and • Multipoint,center averaging • Rectangular discharge opening is UL 181. velocity sensor. designed for flanged duct • Energy efficient fan motor, • Primary air flow balancing connections. permanent split capacitor type, connections. mounted in vibration isolators. This submittal is meant to demonstrate general dimensions of this product.The drawings are not meant to detail every aspect of the product.Drawings are not to scale.Titus reserves the right to make changes without written notice. All rights reserved.No part of this work may be reproduced or transmitted in any form or by any means,electronic or mechanical.including photocopying cml recording,or by any information storage retrieval system without permission in vatting from Al,Dlstnbutiun Technologies,Inc.