Report Cit of Ti ar RECEI120VVED
y g d DEC 2
•
'' Building Division
' 13125 SW Hall Blvd, Tigard, OR 97223 CITY OF TIGARD
Phone: 503.718.2439 Fax: 503.598.1960 3UILDING DIVISION
T I GARD Inspection Line: 503.639.4175
www.tigard-or.gov cSr2o /- ,rye 5 7
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 7103 SW Mapleleaf Ct
City: Tigard Zip: 97223-1175
Owner's Name: Zachary M Shuman Date: 12/20/2021
Contractor's Name: A & R SOLAR SPC CCB #: 207641
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation I I Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ❑✓ No OSSC or ORSC for
design requirements.
Wind Ex osure Is the wind exposure Q✓ Yes If"Yes", qualifies for
p "C" or less? No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes Q . Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load
Is the Ground Snow
Load 50 psf or less?
Installations on all
If"Yes", qualifies for
structures other than —
Yes the prescriptive path.
above
H No
1
I:/Building/Forms/Photovoltaic-Checklist0_'-01-1 Ldocx
Is the construction
✓Q Yes
Type of material wood and does If"Yes", qualifies for
the construction qualify ve No the prescriptive path.
Construction as "conventional light p p
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ✓0 Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
If"Yes", qualifies for
Nominal lumber. Yes the prescriptive path.
❑ No
Is the combined weight ✓ Yes
of the PV modules and ® If"Yes", qualifies for
racking less than or No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance ID Yes «
with Section 305.4(3) of If Yes , qualifies for
n
the 2010 Oregon Solar No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
Q of composition
shingle.
Is the roof mounted 0 Yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof No
to the roof framing or blocking ❑ the prescriptive path.
directly?
2
I:/B uilding/Forms/PhotoV oltaic-Checklist02-01-11.docx
�✓ Yes If"Yes", qualifies for
Is the gauge 26 or less? No the prescriptive path.
115 lbs for 60 inch
spacing or less?
❑ If"Yes", qualifies for
Yes the prescriptive path.
{ ❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
D✓ Yes the prescriptive path.
n No
Attachment of
roof mounted If the spacing falls
Spacing 24 inches
y
solar systems p g of clamps?s? within 24 inches and 60
48 inches inches, qualifies for the
directly to Maximum 60 inches
prescriptive path.
standing seam
metal panels If the width of the panel
Width of roofing is less than 18 inches,
panels? 18 inches or less
18 qualifies for the
inches
prescriptive path.
pve
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? �✓ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. t/2"thickness, �✓ Yes
decking connected to If"Yes", qualifies for
framing members n No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
117/1
solar modules module to the roof Yes the prescriptive path.
surface. No
3
I:IBuilding/Forms/PhotoVoltaic-Checklist02-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: LG Solar Cell Division
Model Number: LG-435QAC-A6
Listing Agency: UL, IEC, ISO, OHSAS
4
I:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx