Report (2) Bend Office (541)330-9155 + • Inc. eotechnical Office (503)601-8250 Carlson Testing, nc. Eugene Office (541)345-0289 Salem Office (503)589-1252 Tigard Office (503)684-3460 November 19,2021 T2104278 L S PANAS&ASSOCIATES(LAKE OSWEGO) 16722 BOONES FERRY RD LAKE OSWEGO,OR 97035 ATTN: DON MULLER Re: BARTON ADDITION 14845 SW 100TH AVE TIGARD OR Permit No. MST2021-00107 NCL UPDATE CTI received and reviewed email from Engineer of Record, Marshall Stokes, dated 7/29/21, which resolves NCL item N2 1 dated 7/28/21 on the Incomplete Items List(NCL). Please see the attached updated list for further details. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. Under all circumstances,the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared.No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. If there are any further questions regarding this matter,please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING,INC. Johnny Johnson Project Manager mrm Attachment:Updated NCL List cc: L S PANAS&ASSOCIATES(LAKE OSWEGO)-DON MULLER DONaLsPANAs.COM CITY OF TIGARD BUILDING DIVISION -WALTER'CHIP' BARNETT FINAL/NCL ONLY KEITH R ABEL RESIDENTIAL DESIGN LLC-KEITH ABEL KEITN.ABELSCOMCA$T.NET VISTA STRUCTURAL ENGINEERING -DENNIS HEIER DENNIS@VISTASTRUCTURAL.COM 8430 SW Hunziker St.,Tigard,OR 97223 PO Box 230997,Tigard,OR 97281 11-19-21(i)rid update.doc Bend Office (541)330-9155 r Geotechnical Office (503)601-8250 Eugene Office (541)345-0289 Inc. alem Office (503)589-1252 Carlson Testing, nc• Tigard Office (503)684-3460 Daily Report of Proprietary Anchors Project: BARTON ADDITION CTI Job#: T21o4278 Address: 14845 SW iooTHAVETIGARDOR Jurisdiction: TIGARD CTI representative: Greg Palmquist was on this site on date: 09/22/2021 to perform Special Inspection for Permit: MST2o21-oolo7 PO#: SCOPE OF INSPECTION Location of proprietary anchors inspected[to include grid lines,elevations 1. Checked in with superintendent or client representative: (floors)and drawing details]: CrI MET WITH DON WITH LS PANAS.OBSERVED DON Name: DON INSTALL(2)5/8"THREADED ROD ANCHORS VERTICALLY INTO CONCRETE FUNDATION WITH 8"MINIMUM Company: IS PANAS EMBEDMENT USINGSET-XPADHFSIVETO ANCHORHDU2 HOLDOWNS PER 5/S2.2 BRACKET ANDANCHOR 2. Inspection was'IBC X Continuous Periodic INSTALLATION(E)FOUNDATION HOLDOWN o2/i 1/21 IN NORTH WALL OF KITCHEN. PROPRIETARY ANCHORS Yes No N/A 1.Reviewed previous inspection reports? X REPORT SUMMARY 2.Reviewed evaluation report? X 1. Work inspected was: I X 1 Completed n In Progress Verified following items meet manufacturer's published installation 2. Completed work inspected Xl was n was not in compliance materials. Yes No N/A with 3.Verified minimum embedment depth of the anchors? X X Approved plans and specifications Shop Drawings 4.Verified installation of the anchors? X 1 n RH n Design Change n Submittal n N/A 5.Verified anchor diameter? X Doc.No(s): PLANS Dated: 02/11/2021 6.Verified steel grade? X 7.Verified hole diameter? X 3. Noncompliance item(s)were noted this date,details on the following 8.Verified type of drill bit used? X page(s):n Yes t n 1 No n N/A 9.Verified hole cleaning method? X 4. Noncompliance item(s)were reinspected this date,details on 10.Verified adhesive application? X following page(s)n Yes n No n N/A 11.Verified edge distance? X H Conform H Remain in progress 12.Verified spacing? X 13.Verified installation torque? X Report(s)findings were discussed and left with DON Evaluation report number and date: ESR-2508.07/2017 of IS PANAS Name of product being installed: SET-XP ADHESIVE Batch Number: 1000154363 Expiration Date: 04/01/2023 Based on the code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered Carlson Testing has no authority to direct work of contractors and subcontractors. n See additional report nasals) 11 Distribute Artac mentfsl Proprietary Andhoss Version 1 Page 1 of 1 Bend Office (541) 330-9155 Geotechnical Office (503) 601-8250 Carlson Testi Eugene Office (.541) 345-0289 ng, Inc. Salem Office (503) 589-1252 Tigard Office (503) 684-3460 Daily Report of Proprietary Anchors Client: L S PANAS & ASSOCIATES (LAKE OSWEGO) - DON MULLER Project: BARTON ADDITION CTI Job#• T2104278. Address: 14845 SW 100TH AVE TIGARD OR Jurisdiction: TIGARD CTI representative G. PALMQUIST WABO SI 02197 was on site this date Sep. 22, 2021 to perform Special Inspection for: Permit MST2021-00107 DFS #(s) PO Number: SCOPE OF INSPECTION Location of proprietary anchors inspected [to include grid lines, elevations (floors) and drawing details]: 1. Checked in with superintendent or client representative. CTI MET WITH DON WITH LS PANAS. OBSERVED DON Name: DON Com an LS PANAS INSTALL (2) 5/8" THREADED ROD ANCHORS VERTICALLY p YINTO CONCRETE FOUNDATION WITH 8" MINIMUM 2. Inspection was "IBC" xl Continuous Periodic EMBEDMENT USING SET-XP ADHESIVE TO ANCHOR HDU2 HOLDOWNS PER 5/S2.2 BRACKET AND ANCHOR PROPRIETARY ANCHORS INSTALLATION (E) FOUNDATION HOLDOWN 02/11/21 IN YesNoN/A NORTH WALL OF KITCHEN. 1. Reviewed previous inspection reports? x 2. Reviewed evaluation report? x Verified following items meet manufacturer's published installation instructions. REPORT SUMMARY 3. Verified minimum embedment depth of the anchors. x 1. Work inspected was: IXI Completed I I In progress 4.Verified installation of the anchors. X 2. Completed work inspected was in compliance with 5. Verified anchor diameter. X Ix' Approved plans and specifications I I Shop drawings 6. Verified steel grade. x 7. Verified hole diameter. RFI (�) Design change I I Submittal I I N/A x 8. Verified type of drill bit used. x Document #(s) PLANS Dated: 02-11-2021 9. Verified hole cleaning method. x 3. Noncompliance item(s) were noted this date, details on 10. Verified adhesive application. X following page(s). I I Yes No N/A 11. Verified edge distance. x 12. Verified spacing. 4. Noncompliance item(s) were reinspected this date, details X on following page(s). Yes I I No x N/A 13. Verified installation torque. x Conform Remain in progress Evaluation report number & date: ESR-2508. 07/2017 Report(s) findings were discussed and left with DON of LS PANAS Name of product being installed SET-XP ADHESIVE Batch Number 1000154363 Expiration Date 2023-04-01 Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. See additional report page(s). I I Distribute attachments. Page 1 of 2 Daily Report of Proprietary Anchors For: 09/22/2021 CTI Job #: T2104278. Project: BARTON ADDITION Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested/inspected only.Information contained herein is not to be reproduced,except in full, without prior authorization from this office.Under all circumstances,the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared.No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. If there are any further questions regarding this matter,please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING,INC. Johnny Johnson Reviewed By:Project Manager Project Manager Review Date:09/22/2021 GP/GP CC: L S PANAS & ASSOCIATES (LAKE OSWEGO) — DON MULLER DON@LSPANAS.cam VISTA STRUCTURAL ENGINEERING — DENNIS HEIER DENNIS@VISTASTRUCTURAL.COM KEITH R ABEL RESIDENTIAL DESIGN LLC — KEITH ABEL KEITH.ABEL@COMCAST.NET X 8430 SW HUNZIKER ST,TIGARD OR-PO BOX 230997,TIGARD OR 97281 Page 2 of 2 Bend Office (541)330-9155 Geotechnical Office (503)6o1825o Eugene Office (541)345-0289 Carlson Testing Inc. Salem Office (503)589-1252 , Tigard Office (503)654-346060 Daily Report of Proprietary Anchors Project: BARTON ADDITION CTI Job#: T21o4278 Address: 14845 SW 1ooTH AVE TIGARD OR Jurisdiction: TIGARD CI'I representative: Greg Palmquist was on this site on date: 09/20/2021 to perform Special Inspection for Permit: MST2021-00107 PO#: SCOPE OF INSPECTION Location of proprietary anchors inspected[to include grid lines,elevations 1. Checked in with superintendent or client representative: (floors)and drawing details]: CTI MET WrrH DON WITH IS PANAS.OBSERVED DON Name: DON INSTALL(7)5/8'XIo"TLrIN-HD SCREW ANCHORS VERTICALLY INTO CONCRETE FOUNDATION WITH 4" Company: IS PANAS MINIMUM EMBEDMENT 4'0/C USING 3'113"PLATE WASHERS PER 9/S1.3 SHEARWALL SCHEDULE S6. 2. Inspection was'IBC QX Continuous Periodic o2/1i/21,INSW GARAGE WALL AND(0)INADJOINING HALLWAY. PROPRIETARY ANCHORS Yes No N/A 1.Reviewed previous inspection reports? X REPORT SUMMARY 2.Reviewed evaluation report? X 1. Work inspected was: EX Completed In Progress materie following items meet manufacturer's published installation 2. Completed work inspected IX was was not in compliance Yes No N/A with 3.Verified minimum embedment depth of the anchors? X n Approved plans and specifications Shop Drawings 4.Verified installation of the anchors? X 0 RFT n Design Change ❑Submittal n N/A 5.Verified anchor diameter? X Doc.No(s): PLANS Dated: 02/11/2021 6.Verified steel grade? X 7.Verified hole diameter? X 3• Noncompliance item(s)were noted this date,details on the following 8.Verified type of drill bit used? X page(s):❑Yes Q No Q N/A 9.Verified hole cleaning method? X 4. Noncompliance item(s)were reinspected this date,details on 10.Verified adhesive application? X following page(s)El Yes No nX N/A 11.Verified edge distance? X' Conform El Remain in progress 12.Verified spacing? X 13.Verified installation torque? X Report(s)findings were discussed and left with DON Evaluation report number and date: ESR 2713.09/2017 of IS PANAS Name of product being installed: TITEN-HD SCREWANCHOR Batch Number: Expiration Date: Rased on the code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered Carlson Testing has no authority to direct work of contractors and subcontractors. n See additional report saris) n Distribute AttachrrunuS1 Pmprietay Au3xrs version i P.A.!„r Bend Office (541) 330-9155 Geotechnical Office (503) 601-8250 Carlson Testing, ugene OfficeSalem Office (541) 345-0289 Inc.Inc• 503) Tigard Office (503) 589-1252 Daily Report of Proprietary Anchors Client: L S PANAS & ASSOCIATES (LAKE OSWEGO) - DON MULLER Project: BARTON ADDITION CTI Job#: T2104278. Address: 14845 SW 100TH AVE TIGARD OR Jurisdiction: TIGARD CTI representative G. PALMQUI ST WABO SI 02197 was on site this date Sep. 20, 2021 to perform Special Inspection for: Permit MST2021-00107 DFS #(s) PO Number: SCOPE OF INSPECTION Location of proprietary anchors inspected [to include grid lines, elevations (floors) and drawing details]: 1. Checked in with superintendent or client representative. Name: DON CTI MET WITH DON WITH LS PANAS. OBSERVED DON Com any: LS PANAS INSTALL (7) 5/8"X10" TITEN-HD SCREW ANCHORS p y VERTICALLY INTO CONCRETE FOUNDATION WITH 4" 2. Inspection was "IBC" x Continuous I Periodic MINIMUM EMBEDMENT 4' 0/C USING 3"X3" PLATE WASHERS PER 9/S1.3 SHEARWALL SCHEDULE S6. PROPRIETARY ANCHORS 02/11/21, IN SW GARAGE WALL AND (1) IN ADJOINING YesNoN/A HALLWAY. 1. Reviewed previous inspection reports? 2. Reviewed evaluation report? X Verified following items meet manufacturer's published installation instructions. REPORT SUMMARY 3. Verified minimum embedment depth of the anchors. X 1. Work inspected was: x Completed I ' In progress 4.Verified installation of the anchors. x 2. Completed work inspected was in compliance with 5. Verified anchor diameter. x x Approved plans and specifications Shop drawings 6. Verified steel grade. x 7. Verified hole diameter. RFI I I Design change Submittal I I N/A x 8. Verified type of drill bit used. x Document #(s) PLANS Dated: 02-11-2021 9. Verified hole cleaning method. x 3. Noncompliance item(s) were noted this date, details on 10. Verified adhesive application. x following page(s). I I Yes No N/A 11. Verified edge distance. x 12. Verified s pacing. 4. Noncompliance item(s) were reinspected this date, details p g on following page(s). Yes I I No x N/A 13. Verified installation torque. Conform I I Remain in progress Evaluation report number & date: ESR-2 713. 0 9/2 017 Report(s) findings were discussed and left with DON of LS PANAS Name of product being installed TITEN-HD SCREW ANCHOR Batch Number Expiration Date Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. See additional report page(s). Distribute attachments. Page 1 of 2 Daily Report of Proprietary Anchors For: 09/20/2021 CTl Job #: T2104278. Project: BARTON ADDITION Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested/inspected only.Information contained herein is not to be reproduced,except in full, without prior authorization from this office.Under all circumstances,the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared.No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. If there are any further questions regarding this matter,please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING,INC. Johnny Johnson Reviewed By:Project Manager Project Manager Review Date:09/21/2021 GP/GP CC: L S PANAS & ASSOCIATES (LAKE OSWEGO) - DON MULLER DON@LSPANAS.CDM VISTA STRUCTURAL ENGINEERING - DENNIS HEIER DENNIS@VISTASTRUCTURAL.CON KEITH R ABEL RESIDENTIAL DESIGN LLC - KEITH ABEL KEITH.ABEL@COMCAST.NET X 8430 SW HUNZIKER ST,TIGARD OR-PO BOX 230997,TIGARD OR 97281 Page 2 of 2 Bend Office (541) 330-9155 Geotechnical Office (503) 601-8250 Carlson Testing, ugene Office (541) 345-0289 Inc.Inc• Salem Office (503) 589-1252 Tigard Office (503) 684-3460 Daily Report of Proprietary Anchors Client: L S PANAS & ASSOCIATES (LAKE OSWEGO) - DON MULLER Project: BARTON ADDITION CTI Job#: T2104278. Address: 14845 SW 100TH AVE TIGARD OR Jurisdiction: TIGARD CTI representative A. IDZARDI WABO SI 01951/AWS 12041141/ICC 8210349 was on site this date Jul. 28, 2021 to perform Special Inspection for: Permit MST2021-00107 DFS #(s) PO Number: SCOPE OF INSPECTION Location of proprietary anchors inspected [to include grid lines, elevations (floors) and drawing details]: 1. Checked in with superintendent or client representative. Name: ERICA OBSERVED THE INSTALLATION OF SCREW ANCHORS USED Company: LS PANAS ON WOOD LEDGERS AT NEW ADDITIONS BACK WALL AND AT WOOD LEDGER UNDER FRONT OF HOUSE WALK WAY. 2. Inspection was "IBC" Continuous xI Periodic EDGE DISTANCE FROM TOP OF FOUNDATION TO ANCHOR AT FRONT OF HOUSE WALKWAY WAS LESS THAN THE PROPRIETARY ANCHORS REQUIRED 1 1/2", WHERE 9OFT LBS WAS NOT ACHIEVED YesNoN/A PER 10/S2.1 ENGINEER APPROVAL IS NEEDED. 1. Reviewed previous inspection reports? X 2. Reviewed evaluation report? x Verified following items meet manufacturer's published installation instructions. REPORT SUMMARY 3. Verified minimum embedment depth of the anchors. x 1. Work inspected was: I x I Completed I I In progress 4.Verified installation of the anchors. X 2. Completed work inspected was not in compliance with 5. Verified anchor diameter. X y Approved plans and specifications I I Shop drawings 6. Verified steel grade. x 7. Verified hole diameter. RFI I I Design change Submittal I I N/A X 8. Verified type of drill bit used. x Document #(s) 2969 Dated: 02-1L-2Q.21 9. Verified hole cleaning method. X 3. Noncompliance item(s) were noted this date, details on 10. Verified adhesive application. X following page(s). Yes No I I N/A 11. Verified edge distance. x 12. Verified spacing. 4. Noncompliance item(s) were reinspected this date, details on following page(s). I I Yes No I x I N/A 13. Verified installation torque. x Conform Remain in progress Evaluation report number & date: ESR-3037;08/2016 Report(s) findings were discussed and left with ERICA of LS PANAS Name of product being installed SIMPSON STRONG BOLT-2 Batch Number Expiration Date Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. See additional report page(s). I I Distribute attachments. Page 1 of 2 Daily Report of Proprietary Anchors For: 07028/2021 CTI Job #: T2104278. Project: BARTON ADDITION Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested/inspected only.Information contained herein is not to be reproduced,except in full, without prior authorization from this office.Under all circumstances,the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared.No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. If there are any further questions regarding this matter,please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING,INC. Johnny Johnson Reviewed By: Steven W Leach Project Manager Review Date:07/29/2021 AI/AI cc: L S PANAS & ASSOCIATES (LAKE OSWEGO) - DON MULLER DON@LSPANAS.COM VISTA STRUCTURAL ENGINEERING - DENNIS HEIER DENNIS@VISTASTRUCTURAL.COM KEITH R ABEL RESIDENTIAL DESIGN LLC - KEITH ABEL KEITH.ABEL@COMCAST.NET X 8430 SW HUNZIKER ST,TIGARD OR-PO BOX 230997,TIGARD OR 97281 Page 2 of 2 Carlson Testing, Inc. Incompleted Items List(NCL) Jul 30,2021 T2104278. Project Name: BARTON ADDITION Project Address: 14845 SW 100TH AVE TIGARD OR Permit No: MST2021-00107 P.O. No: Project Manager: J. JOHNSON Item# Insp. Date Item Description Compliance CTI Sign-Off Date Corrected 1 AI 07/28/2021 OBSERVED THE INSTALLATION OF SCREW ANCHORS USED ON WOOD LEDGERS AT NEW ADDITIONS BACK WALL AND AT WOOD LEDGER UNDER FRONT OF HOUSE WALK WAY. EDGE DISTANCE FROM TOP OF FOUNDATION TO ANCHOR AT FRONT OF HOUSE WALKWAY WAS LESS THAN THE REQUIRED 1 1/2", WHERE 90FT LBS WAS NOT ACHIEVED PER 10/S2.1 ENGINEER APPROVAL IS NEEDED. CC: L S PANAS & ASSOCIATES (LAKE OSWEGO) - DON MULLER VISTA STRUCTURAL ENGINEERING - DENNIS HEIER KEITH R ABEL RESIDENTIAL DESIGN LLC - KEITH ABEL X Page: 1 Carlson Testing, Inc. Incompleted Items List(NCL) Jul 30, 2021 T2104278. Project Name: BARTON ADDITION Project Address: 14845 SW 100TH AVE TIGARD OR Permit No: MST2021-00107 P.O. No: Project Manager: J. JOHNSON Item# Insp. Date Item Description Compliance CTI Sign-O Date ff Corrected 1 AI 07/28/2021 OBSERVED THE INSTALLATION OF SCREW ANCHORS USED ON WOOD LEDGERS AT NEW ADDITIONS BACK WALL AND AT WOOD LEDGER UNDER FRONT OF HOUSE WALK WAY. EDGE DISTANCE FROM TOP OF FOUNDATION TO ANCHOR AT FRONT OF HOUSE WALKWAY WAS LESS THAN THE REQUIRED 1 1/2", WHERE 90FT LBS WAS NOT ACHIEVED PER 10/S2.1 ENGINEER APPROVAL IS NEEDED. CC: L S PANAS & ASSOCIATES (LAKE OSWEGO) - DON MULLER VISTA STRUCTURAL ENGINEERING - DENNIS HEIER KEITH R ABEL RESIDENTIAL DESIGN LLC - KEITH ABEL X Page: 1 1 # r t r t �^ G ma i I Don Mueller<damueger74@gmail.com> RE: Barton -laundry room 1 message Marshall Stokes<marshall@vistastructural.com> Wed,Sep 22,2021 at 4:04 PM To:Don Mueller<don@Ispanas.com> Hi Don, How does this look?: I I I r ( I (E)2x6 CEILING 10t6T5 24^O.C.,TNT ADD 2x ICKERS EROM 3Y x9Y'GLS �S ` RIDGE TO REPLACE(E#NNEE $t.t >> WALI tO(EH ING RASES JI. '_ i I I i St.l #Eli4l2«L2 '- t I r — —t _ _ _ _ ....( .„ it (E}KNEE WALL FROM RIDGE - I I \\ r .--� TO CUING JOISTS --' •`-✓� #2l 243 JO titu u LI u w y I 0 X C ----3I i qd► m E-1 _ - �v _ 3 '2 ' Ir 31 — — 4 _ — _ �4— �N� ^� SIMPSON a vt < z IruC610 C .... .... �J ._ WO + 1. Marshall Stokes,PE Vista Structural Engineering,LLC 1 14718 NW Delia Street Portland,Oregon 97229 Cell:503.737.5932 Gmail Don Mueller<damueller74@gmail.com> RE: Barton 1 message Marshall Stokes<marshall@vistastructural.com> Fri, Sep 17, 2021 at 3:23 PM To: Don Mueller<don@Ispanas.com> Cc: Keith Abel<keith.abel@comcast.net> Ok, so, the only change we'll need is the 3 '/a"x10'h"glulam will need to be upsized to 31/"x12". Will this work? The 3 '/�'x91/2"glulam header is good, as are the footings. Are Simpson HU210-4 hangers readily available?We'll want those where we trim the 4 ply beam. Marshall Stokes, PE Vista Structural Engineering, LLC 14718 NW Delia Street Portland, Oregon 97229 Cell: 503.737.5932 V IuSTA L From: Don Mueller<don@Ispanas.com> Sent: Friday, September 17,2021 2:47 PM To: Marshall Stokes <marshall@vistastructural.com> Cc: Keith Abel<keith.abel@comcast.net> Subject: Re: Barton I believe there is a beam line in-line with each side of the hallway to the bedrooms. On Fri, Sep 17, 2021, 2:14 PM Marshall Stokes<marshall@vistastructural.com>wrote: Don, one more quick question, and my getting you an answer isn't dependent on this, but do you know offhand if there is a beam line in the crawlspace under this beam? Marshall Stokes, PE Vista Structural Engineering, LLC 14'718 NW Delia Street Portland, Oregon 97229 Cell: 503.737.5932 1111140$ Gmail Don Mueller<damueller74@gmaii.com> RE: Baton 1 message Marshall Stokes <marshall@vistastructural.com> Thu, Jul 29, 2021 at 8:47 AM To: Don Mueller<don@Ispanas.com>, Keith Abel<keith.abel@comcast.net>, Erika Narvaez Arreguin <erka@lspanas.com> Hi Don, Per our discussion, please use t/," SDS screws @ 6" o.c. from the ledger into the existing mud sill in place of the Strongbolts. Please use a screw long enough to achieve a min. 1 Yz" embedment into the sill. If the ledger splits, please predrill the holes. Let me know if you have any further questions. Thanks Don! Marshall Marshall Stokes, PE Vista Structural Engineering, LLC 14718 NW Delia Street Portland, Oregon 97229 Cell: 503.737.5932 ♦'L/ VISTA AL From: Don Mueller<don@Ispanas.com> Sent: Wednesday, July 28, 2021 5:00 PM To: Keith Abel<keith.abel@comcast.net>; Marshall Stokes <marshall@vistastructural.com>; Erika Narvaez Arreguin <enka@lspanas.com> Subject: Baton Hey there, I having an issue with the detail for the 2x6 PT ledger at the existing house. Detail 10/S2.1 show the concrete stem wall even with the top of subfloor. The existing condition is the concrete is 3"below top of subfloor, see attached sketch. The wedge anchors are blowing out the concrete and we can't get the 90 ft-lb required by the special inspection. Can we screw into the existing sill plate or even run kickers under the ledger to the footing? Pi rnait Don Mueller<damueller74@gmail.com> RE: Barton - Headers 1 message Marshall Stokes<marshall@vistastructural.com> Thu,Jul 22,2021 at 1:50 PM To:Keith Abel<keith.abel@comcast.net> Cc:Don Mueller<don@Ispanas.com> Hi Keith,Don, Don,thanks for catching this.The living room header should be a 3 1/2"x12"glulam.The nook header has very little load and can be a 4x8.Obviously, we're fine if you want to upsize it. ti U w 3 ,12''.;L2 Please let me know if you have any additional questions,and thanks again. Marshall Marshall Stokes,PE Vista Structural Engineering,LLC 14718 NW Delia Street Portland,Oregon 97229 Cell:503.737.5932 � �' VISTA From:Keith Abel<1,,e;t11.abel@comcast.net> Sent:Thursday,July 22,2021 1:38 PM To: Marshall Stokes<marshall@vistastructural.com> Cc:'Don Mueller'<don@lspanas.com> Subject: FW:Barton-Headers From: Don Mueller<don@Ispanas.c or > Sent:Thursday,July 22,2021 1:40 PM To: Keith Abel<keith.abel@comcast.net>;Erika Narvaez Arreguin<erika@lspanas.com> Subject:Barton-Headers Keith The headers at the front living room and the nook are not called out. It says that headers not noted are 4x8 but I think these,especially the living room,are much bigger. Please advise. The frarmers are starting tomorrow,so the sooner the better. Thanks, Don Mueller Project Manager LS Panas&Associates (503)799-2943 CCB#149456 Virus-free.www.avg.com