Loading...
Plans f, CITY OF TIGARD Markup Legend SPRINKLER SYMBOL DEFINITION X, COLOR/LINETYPE LEGEND Approved [' y BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). o Delete Line XXX-XX pp GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. w " I Contitionally Approved [ BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. CO a z MAXIMUM SPACING(TYP) r �X� = 1/2"PIPE SIZE Add Line HEADSPRINKLER SYMBOL(EL(TYP) For Only the WO(h as described In" Cw� SYMBOL(TYP) —n— =3/4"PIPE SIZE iti rn C, Add Tee I I ` PERMIT NO. Y►'1ST;°a7- 00153 _,_ = 1"PIPE SIZE 0 Q°'�� - See Letter to: Follow [ ] = 1-1/4"PIPE SIZE a"'a W a LL O Add Elbow [ 1 Q , -,,=a Attach J Kn�� Add Coupling A ADU-1 SFU r Job Address: l�l+�a� Sw tG qvP =<No� g Date: p.128312� 3 I I 1 --1_ tt /►. Add Head -E --0--(�A.3- I y• A/ / 2 p 3 f Q 1 L �m3 I I 1 Delete Head I / fit D4 Dt y a °i a J E Move Head I ••;I I 2U=a"�z zoCoz iO' 0_ 2 STORY TRIPLEX 2'-a' r {{2'd'I ' t 2 i E n. z 0 0 R Ei y 0 u 3-011-6F 3-011-6 FI rii."';e-lN g6? Note:All revisions must be reviewed by Uponor OVER OVER ,,, 1- I u m ti m z 2,T x m �L:e 3-0 -0F 3-0 -0 FI Porch••f 0 R-_ (\/�'" r {-P mz^� al, Table Table F002-1 I• " lE`�/�� ED :sZop�r�u�o�'�� Ftd'l, Ft i i B._2. -�� "" ll =o N _ LL • v y ON Cz Multipurpose Fire Safety Systems e1N r— —1 _ ry 1 ••• • 1' zz,..„ mor;,i1yoC U. The Uponor Residential Fire Safety System is a residential fire protections -a O q to - ) Living S 0 o o 0 z a x 0_o$� U system installed in combination with the cold side of the domestic potable '' "'` 7 I r/ Z a"'0 a°! Qp r <a zy y 3 KEY PLAN Q(I f W momya� 3" water system. Only licensed contractors trained by Uponor can install this - NOVe*2.'' NOV v LU2 6 0 g o a a y �z o system. I ,E I.., z z $1 y-3 v, 100 h� I II' g 'z<oozoox o z ` NTS V \ H.15 Ent CITY OF TIGARL " z�� � w �` � What[o do if Changes are Required / ^'.9 0 If any features or obstructions require the addition or deletion of sprinkler \ .. 6 `RC" 18 ( 0 w.<d°z 0O z°_ `a'`O-' heads,or significant relocation of sprinkler heads,contact the Uponor Design 7` 0 m F v''..p a E o b 0 0"'1, Department to determine if observed changes require a redesign vin i SEE SHEET ADU E�UILDING DIVISION �'x�zu8od� a (sa (888.594.7726). R xzW,.,z uc F- ��1 888.594.7726. / ' E2 FOR STAIR z 0 .wH °z a'm`c3`o P. TAILS (221200A) o MOST HYDRAULICALLY REMOTE HEADS I E° INSULATE FLOOR ao0xyg6E�ioh 8 HEAD# GPM PRESSURE REQ'D AT STREET I ® + • OVER CRAWLSPACE o z 0°a o 0 a o o y m / LOW(WALL AT Dyo� �o�yZN o 1 HEAD H.11 17 71.24 N. \��� Jj. +'xNoyr�G 1 l �' V y O E g '�5��m 2 HEAD H.1&H.5 26.00 87.52 -- - 2 3 6 6 9 1-1/4"AQUAPEX TO ig Rgg., p�gF, 6 T.38 '(22 300A) SYSTEM E1 za V.--g2,H 1 # # ozao" ', w m 1 'T.39 rl: FLOOR _ / tivuauub0 ¢ LI SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 t� C:a9:r. PACE �; m ® - - - 17 K=4.9,162F°,7/16"Orifice,Maximum Spacing 16'x16' __ : Q \.. .3y Di'kig K SPAwat i 1 it c�'• Ow 1 RC-RES-16 Sprinkler head demand: 13 gpm @ 7.04 0 /\RC-RES-16 \- -, "7 r-,..., 41 I C` iI a. F J t S.1 MAIN SHUTOFFI here by certify that this plan,specification, SENJU Model RC-RES205 Residential Flat Concealed Pendent SS8464 1•AQUAPEX INTERLEVEL / e _ VALVE LOCATION or report was prepared by me or under my ® - - - 1 K=4.9,205F°,7/16"Orifice,Maximum Spacing 16'x16' CONNECTIONS FROM FIRST 711" O direct supervision and that I am NICET Sprinkler head demand: 14 m @ 8.2 X �,p �'! IC certm FLOOR TO SECOND FLOOR q •••p Kit •-n • RC RES 16 205 p 9p \\ lir + , g.), SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 \ H— T.T4 ' Brent Kotula '"7/F�21 0 - - - 2 K=4.9, 162F°,7/16"Orifice,Maximum Spacing 18'x18' ,f"� ;��Q A N NICET Certification No.113889 RC-RES-18 Sprinkler head demand: 17 gpm @ 12 ' `Y� I, ." 4 water-Based Systems Layout-Level IV Q"lJ o I �'O I.B,•-- .,': T�`. f.! --- _ _ _ Certification Expires:June 1,2023 12 zed Floor 'RC-RES-16 T.4�� tires' s-1o' ,�. 1Yz' 2._t. ,. 6' _ 2-B n su—PLATE*. } 20 TOTAL —It— ^ ^ I L PLATFORM AT ,y ptATF••• • PROPERLY PROTECT AND 11;C //fS ` / -ran ABOVE SLAB +18"ABOVE SLAB INSULATE PIPE TO MAINTAIN I/\ \\ i WOOD TREAD,MAX. WOOD TREAD,MAX RISER 8• A MINIMUM TEMPERATURE z ' -� RISER 8'(ADD AS (ADD AS REQUIRED PER SITE OF 40°F PER NFPA-13D,TYP. W m REQUIRED PER SITE CONDITION)MAX.2 TREADS x f w I if., ' S• m CONDITION)MAX.2 D f M _ I m .L—A.',/ ♦ TREADS e LU d 0 _ ut-n rvo q-..r ^ Qz^ n 1-1/4"AQUAPEX r' CURRENT STATIC TO SYSTEMGarage F—i NIa(1"n o., Mr x 25 U 1:4301 tl Fl. t) - g Garage .J f S.1 '— Garae WATER PRESSURE TO HOT WATER -- u/ H. WALL FINISH A"G.W.B. g 0 HEATER TOWEL CEILING FINISH)b"TYPE'X'G.W.B. WALL FINISHG4 z o _ w z STATIC: 105psi ^' T, RING RC=RE516- FIRETAPE ALL G.W.B. , f CEILING FINISH N i g O � L WRAP BEAMS BELOW CEILING LEVEL TYPE X'G.W.B. z 6i V.a" E 1 1/4"AQUAPEX RISER— F.gg FO INSULATE FLOOR ABOVE PRETAPE ALL G W i a t5 z 0 z PRESSURE GAUGE r '�' '° WRCEILING LEVELP BEAMS ( UJ X/ O O o o_ w 1 1/4•PRV CASH ACME T * INSULATE FLOOR AB /w� U O u¢a,Tog (OR EQUIVALENT) • 1"WATER METER 6PSI LOSS FLOWING 26 GPM CD T.35 T.37 9 Q - w x 3PSI LOSSNFPA 13D S LOW FLOWING 26GPM ANDARD LOSS 80 psi O R S-8 , I® DS FLOOR ABOVE 5® - Ce 1. 1 Q PRV Set Pressure r ,(� MTR SHUT OFF VALVE Yp _ J I g CURB STOP —� �b roa �I i 1PSI LOSS w I FLOOR ABOVE �\'/ W .. i 8-06I0 SOHD 0 o o p, ` 76-OB SOHD I c z I' STREET '� 9'-0• 8'-a^] - M s-e' o r P" I I_II_1- I M" „: J \ Den/ 0 1 I 0 r 'm" CORPORATION • —J+ W O Q STOP 1PSI LOSS f • -- "'I 1 > l/�MU s y m £L' a WATER Q 1 TEE •+ EGRESS - I F�- I/ V/ 0 i w K F LL MAIN © e=0 50'OF LL I11 3 u `'' fiEV=95' EIEV-9T Lii 1 1/2"AQUAPEX Q 50'OF I 3-B slo SH a o u V,N a i 10'OF 25'OF 1 1/4"AQUAPEX 1"COPPER-K i'COPPER-K SHEET DESCRIPTION 1 FIRST FLOOR FIRST FLOOR ADDITIONAL 10GPM AT TEE FOR SHARED SUPPLY .10(:), 1/41t 1 f_O tl FOR OTHER UNITS SHEET NUMBER �o WATER SERVICE DETAIL — 5 0 5 15 �10.9 NTS 1/4•=i'-0• F100 --------- © UPONOR - CONFIDENTIAL 1 Markup Legend SPRINKLER SYMBOL DEFINITION , COLOR/LINETYPE LEGEND `_ Ln BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). Z o Delete Line � � XXX-XX GREEN LINE` RLEVEL CONNECTIONS/SUPPLY. w BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O - o MAXIMUM SPACING(TYP) = 1/2"PIPE SIZE 'E.,-° Add Line — — — — — SPRINKLER MODEL(TYP) HEAD SYMBOL(TYP) =3/4"PIPE SIZE < g° Add Tee I I = 1"PIPE SIZE 0 i rr u - = 1-1/4"PIPE SIZE El t w o u� utz Add ElbowI-1 CI >5'°Z O Add Coupling I I = 2avo++03 I I I i M W;W Add Head -10\-€3--9.3- 0 v'i-W x. \ Delete Head -7�X o ZxEZ o=m= l IX� �' ��og� °°3 Move Head I �~ r , `<-' `?ay=°rayEliit - - _ - h o4, I I G03O02 Z� -mO Note:All revisions must be reviewed by Uponor •'C-r e m 1 g a.'' o,1° I-Eo�o i Table F002-1 I i -,305}O SH 3-05FO SHQJ I I am22?8 'c'$dC"' z' Multipurpose Fire Safety Systems 23-4' 9'A 2'4'L EGRESS Z4< '42m o The Uponor Residential Fire Safety System is a residential fire protections t 1 18 S y c 2°w a o o- �' Al o system installed in combination with the cold side of the domestic potable ROOF BELOW DI W m o m,> a°I~— 3 a l water system. Only licensed contractors trained by Uponor can install this 3-040 SH 3-0 5405E c• z °a tt f a < ; ;•.1 I I—i -1•• '^ -19 < aa�N �- sYstem. - EGRESS ® EFpz ooEyS3i a6"7"22€ed5g6so What to do if Changes are Required O' Al `° V.-.16—' 4$ °0 X 3 N a If any features or obstructions require the addition or deletion of sprinkler -- L 0 ) N fii a.Pe O §.Z u <h i< heads,or significant relocation of sprinkler heads,contact the Uponor Design = : S&P !� ` m m o z u v, y y Department to determine if observed changes require a redesign (:7 - qy E Z v of S o o _ a �' ,'i g g'� Z u n i? (888.594.7726). ..�_z—, i � Main Bedroom aa ��2`=K,gE<i'2 W.I.C. y Main Bedroo -� t o,Tin64°a8 ' °o SEE SHEET .ka . $� soh <v+ u 5" 2FOR STAIR. m ",?o � "�_,m� f"--. . J i 8DETats' AD��� ' tgd. og,R o,o w RC S 16 R S 1 ;, (221200A) 2 T.30 0s&P • 2-0 HON Lut d � A D(221300A) �T)1 -t�i TO BELOW .I OPEN 1 I y " .)1-T2' m ^.lk• 3. 3'-11}�• 011 6'-8)• S.-8. I here by certify that this plan,specification, - _. f L�- View 1., Ii a or report was prepared b me or under my Y} F . .5-16 . W I•C• `a di�supervision and that I am NICET ` SH"eLhS / 34x60 ' LOW\� " Ili E�•„� 23 SHOE. WALL AT/ \ II � M. Bath -/ : y i +42'A.EF. �I i IM. Brent otula Date: 1 1,M 1"AQUAPEX INTERLEVEL / 1 i H Z 1 •( - 03 z,re S&P NICET Certification No.113889 CONNECTIONS FROM FIRST < L ^ l water-Based Systems Layout-Level IV FLOOR TO SECOND FLOOR • j RC-RES-16 Z• +� Certification Expires:June 1,2023 \q ' ` M. B \ ♦ I- VOID NOV S =- m K x —` - , I WASHEld DRYER N. �SP/ . —fin I �. 34K60 1l R)I (am I9[CESN (- r .' HOWER Laund • ....a� .t. x \ •�\ T a S&P m 2-8 HLw f w ill H.3 . "'I ` .. j 28,20 UP�RS LL� .-O o v. 2 RC =' �` 7 Fr W.I.C.i� J �1� gi:: �T 2, V i e d �ry - S SHE VTs. Ii-• �� H.12 I S I&,,P .;,fA,o� 24.Ta r i '4SOP*PASS i---1 ^' a 1a7 u�t N o S&P T., ( ie16:aCW 40 :+/"- ~ ,1 E 14 FT' ; ( �'7 p �a I z'-m• = O i 0 .i u' o SOB PASS z` 1. ..� }l RVr�G•Y18 < 5 6;-Z 0 L O 1 _ as w X gt. viols=mow �I Bedroom 2 .- Bonus U LLI y i H4 Laun.H.� Bedroor Q —I NA/LATE FLOOR RC-RES-16 DI q C RRRRfS 1.-205 EATEDLOOR f INSULATE FLOG a 1x� l r UNHEATED SPA+ I.d. o ® \ Bedroom 3 , ''' k — 1� Ce �l N. i / WASHER �-- -�/ I W H O o Z F E II h o x d ,,, E�5 �.�/ oZ�m --"�i9 2-0lo SH 5-0toA I, 1, O I..L F m t�lf.ter F. O N I I r EGRE' �H Q 1 . ---- I-- --I -1 L > u) c� o = 3-0 5�0 SH ] OF BELOW ♦ 15 1{ ~� H z t.F g I I ' A I I N o�IwgFa F ROOF BELOW I I SIM. a o',u In Z I w I I SHEET DESCRIPTION L--__L__—__-- I I I SECOND FLOOR 1 SECOND FLOOR S 0 SHEET NUMBER 5 15 101 i/^EE i E_0u 114•=P-O" 1 `1 1 © UPONOR - CONFIDENTIAL F101 Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations f r AquaSAFE GENERAL GENERAL NOTES: In areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.8 for Architectural ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements vs Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor ` z 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2019 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Fire Sprinkler Adapter SECTION 3.3.12.3. Blocking Maybe--� on Nut Document"Uponor AquaSAFE Attic Insulation Guidli s for attic O W O Required.IfPr'sfi installation guidelines(Provided in Contractors Documents package or online -----\ Blocking is Used, at www.Uponorpro.com). ; O 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON 1 Ye Min. I LT- Use ¢,�z The 2 Top I m p THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND 1 "Max. J o-g Screw Holes. ■I�I■, Planter Box Window,Bay Window or Similar Feature. UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. r--� C , Br acket maaMe of TrussExtreme Temperature Installations If no additinal Floor area is created No Additional Sprinkler is Required. a�, AquaSAFE Residential Fire Safety systems are often installed in attics or Q o,m 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adake ' ac other areas exposed to temperature extremes of heat and/or cold. Follow O t . w�^ RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE p p p 8'-0"or less m n u O Mounting Bracket the recommended extreme weather installation instructions to isolate and " a> PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE l - � �_-- I w!u.w O SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE protect system components from extreme temperatures. Because this RC -i6 „w m z SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1 1/2" 0 system also delivers domestic cold water directly to plumbing fixtures, ® N w z MMIO 9'-0"or less >„n g _ Uponor highly recommends that you protect the tubing with adequate �' ..2_, m m n O O 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Full Course _ insulation in warm weather areas to minimize heating of the cold water c N£g w 3 Thread Screws 5 - u, - z m a o i NFPA 130 2019 EDITION. supply. In Bottom Holes o= o } O- -3 Tv 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE PERMITTED TO ONLY USE ANTI-FREEZE • Installation methods include,but are not limited to: o 'D W m=W LISTED FOR USE IN NEW SPRINKLER SYSTEMS. "IO. • Tenting over the fire sprinkler piping. O'^1"W; Lead-Free Flat..- ......-' Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft,be more than 2'-0" 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Concealed Senju. • '' Concealed Flat • z Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the � a � o DAMAGED MUST BE REPLACED. Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. C o, i `5I ; Caution: If you will be installing spray foam insulation,make sure to y F $z 3 0 0 7. A SINGLE CONTROL VALVE ARRANGED TO SHUT OFF BOTH THE DOMESTIC SYSTEM AND THE SPRINKLER o o -�'"3 SYSTEM SHALL BE INSTALLED. Senju RC-RES:Traditional Wood FramingConstruction protect all components during application.Consult with the spray foam a s❑y o c m J manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.6.3 Distances From �'i zd y z c z$ai o i Heat Sources c„"z°��,a,�" '„a 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. u o o$ z oym Consultation with local building officials is encouraged to ensure compliance ' m ze_a o 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING:THE ProPEX LF Brass Fire with local building codes. U c a c u z o 3 4y a Ordinary Intermediate ?:yu.;a z WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Sprinkler Adapter Tee Fire Sprinkler Adapter o 0 o a x o °�°�z p p -� q Push-on Nut Heat Source Temp. Temp. dm y o h_ C F F PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR f o i 135,170° 175,225° z$o PoEsz .o AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, "`' SendingPEX TubingU o FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM ,. -{ 1 K.Min. The minimum bend radius of Uponor PEX tubingindirection Is six times Side of Fireplace 36" 12" ITC S °o zd o< 9 0 WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVEDany Front of Fireplace 60• 36" W m c is y g, q2 z 3 w THIS SIGN". 1 Max. the outside diameter(6 x OD). c o N a Bottom M Mounting Wood Burning Stove 42" 12" ty a o a a f.u, q p Fire Spun der Adapter ,, _ - Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Kitchen Range 18" 9" i z i o o a•a,>3 i Bracket to or,. of Truss 0 i a F i 2 C 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. Mounting Bracket tubing to facilitate 90-degree rigid bends. g b a h o 0 0 Wall Oven 16" 9" . a��-a u Q '�" U`zd- ca o"5� a 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. 2-#10 x 1 1/2" (c \ Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" w <d a u >,u Full Course _ _--2 g. . �a, a q.a° 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING Thread Strews �-/: t(L Fitting Size Minimum Tubing Length Uninsulated Heat Duds 18" 9" C m EC o S u z m d I.zo p i BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE In TopHoles t/ CJ Uninsulated Hot Water Pipes 12" 6" �y E z�F $o o�.n 3/8"ProPEX Fitting 2,� F2 z $3 h,, c x o RESTRICTIVE SPACING LIMITATIONS. Side of Hot Air Diffuser 24" 12" Ott'-'. o 1/2"ProPEX 2• ? yiwdy=�� z 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING �. _a Hot at r H at Diffuser 36" 18• 3 o m 5 0 0 w 0`' o xi 3/4"ProPEX Fitting 3" Hot Water Heater 6" 3" �a z o a<u o o y d F m MOUNTED OBSTRUCTIONS. Lead-Fre6•Flk ,"!'Y •y J o o Z o:e o"v,o o Concealed Sernu - N4'i r" '` J 1"ProPEX Fitting 3 1/2° Furnace 6" 3" o m o y u�' >a o 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE concealed Flat y❑p m a 8 m-i�z Sprinkler Head Cover Plate 1 1/4"ProPEX Fitting 4 1/2" SOW-250W Light Fixture 6" 3" u o m m SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. 2�m �o''>u�h°z a 6 250W-499W Light Fixture 12" 6" yu2asy $y-_- z u 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN y>z 3 Ci o-a m x a i g CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS \ y o. q'qa THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. Exposed Installation e)and Requirements. ¢ Uponor AquaPEX'tubing(white)and ProPEXT"'EP Fittings and ProPEXI"' \ I m 16. NFPA 13D 8.2.5.OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Brass Fittings are approved for exposed installation where the following • 8.2.5.7. SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS conditions are met.(UL 1821 Approved) THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT'PER SPRINKLER. oa • 8.2.5.8 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY Exposed Wood Joist Ceiling Assemblies. o ri o I here by certify that this plan,specification, WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: 1. Joists are of dimensional lumber,engineered wood or wood I-joist. '° �' °® or report was prepared by me or under my (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO 2. Joist are of depths from 6-16 inches(152-204 mm). m direct supervision and that 1 am NICET ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. CertiB . (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL 4. Joists can be exposed after installation. I❑ SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT'(1.7 Mz) are used. 3.55" 'I 1.66" (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 24 INCHES IN DEPTH AT THE DEEPEST POINT OF 6. Listed residential automatic sprinklers of maximum activation Brent Kotula Date: THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED temperature rating of 155°F(68°C). I" -3" Hanger 1" Hanger NICET Certification No.113889 ALONG THE FINISHED FLOOR. d Water-Based Systems Layout-Level IV (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE Tubing Support Spacing: Certification Expires:June 1,2023 PLANE OF THE PRIMARY WALL. Metal Tubing Support. (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER (Anchor AquaPEX Tubing g Securely Expand Enough to Support the Tubing,Yet Relaxed SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. 1. Metal tubing supports designed mfoa plastic tubing shallp ctbe used. Enough to Allow the Tubing to and Contract) (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 2. supportsDo not user supports that will damage the tubing.Inspect metal ARCHITECTURAL FEATURE. Do for sharp or ges. 1. Clung Horizontal S Runs,te Install Supports Every 32",at if -Foot Runs are 3. Do not rigidly anchor Uponor AquaPEX'"'tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each C1tt^11. • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 Floor and at a Mid-story Guide. LLJ Z THROUGH 8.3.8. m • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT'(5.1 M')AND LESS In-line Flow Test X x w • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT The In-line Flow Test can be constructed on site. It performs a flow test to -' e' - MEET ALL OF THE FOLLOWING CONDITIONS: High Upstream Pressure ensure proper system operation and flow(see Figure F001-8). W a=S. c c (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 M'). �' u If the upstream pressure exceeds 80 psi a pressure reducing valve may z I-z N ii (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE needlytor be installed.lssfSome jurisdictions may require a pressure reducing o MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. � �¢N�o valve regardless of upstreampressure. Uponor AquaPEX • SI MI SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND g D j' Tubing ~ (y ¢-� SIMILAR STRUCTURES f I w • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE ' EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND i CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, - -. Q =o W¢ zO CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVINGz. PURPOSES. < Z G V G Hui • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR -. / n¢<z o 8.3.5.1.2. _. - s >:zz=pw O O O J J=m • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING LLJ X u u u¢ m z p UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. ihreaded Coupling ProPEX Fire , l 0 Sprinkler Adapter U LU iii • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE w DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Q J INSTALLED ABOVE THEE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED {.-- Male Threaded Coupling1°Ball Valve (_S7 Q ■ --- To Hot Water Heater �.. EQUIPMENT FROM THE OCCUPIED SPACE. E I Female Threaded ~ Ce O • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN UNHEATED ENCLOSURES AT THE BUILDING AT Tee with Water O' ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER ENTRANCE/EXIT. y Pressure Gauge ¢5 • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING �. Pressure Gauge Sprinkler Orifice LLJ 0 z F CONDITIONS: o m "• 9 (Optional) 0 0 0 (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED m v I- > o y a d 100 FTa(2.83 M'). a 0 o f~ m (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS _ Flow Test m f AT THE LOWER CEILING ELEVATION. N rn To ensure the system provides enough water for proper fire sprinkler O Ce F m m.+ (3)•THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE `a ` performance,you should conduct a flow verification test. w c U Uponor WarningSigns TREATMENTS I5 NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. -Tr " pNote: The NFPA 13D Installation Standard does not require flow ,�,/^� i y m ¢ (4)SKYLIGHTS NOT EXCEEDING 32 FT'(2.97 M')SHALL BE PERMITTED TO HAVE A PLASTIC COVER. n verification. V/ m o O • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS u, " I-I HI b z Y g F L (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR o n tY, Pressure Reducing ('V 3 w m ¢ Before performing a flow verification test,confirm the water pressures by s i ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED - z ,'q, Valve contactingthe Water and Sewer Department ofyour local city. Ensure the d O PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. c "w p O u iy Yt m z available water pressure matches the pressure used in the system design. • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING m °i �qI-I�( SHEET DESCRIPTION EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. ` 1, Note: The sprinkler plan indicates the most hydraulically remote sprinkler 18. INSULATION GUIDE LINES PER NFPA 13D. ct;7-4 " Main Fire Sprinkler (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS -- Shut-off Valve your local code. • 9.1.1°WET PIPE SYSTEMS. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE USED WHERE ALL PIPING IS INSTALLED IN AREAS NOT SUBJECT TO FREEZING,INCLUDING AREAS PROPERLY INSULATED TO rNote: It is a good idea to notify the fire inspector at least 24 hours prior to MAINTAIN 40.F. performing a flow verification test.This may speed up the inspection •e A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO I process and eliminate the need to repeat the test for the inspector. SHEET NUMBER COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE I INote: See"AquaSAFE Flow Test Instruction Sheet"(Provided in GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.3.1(A)THROUGH FIGURE A.9.1.1(F) ' Contractors Documents package or online at www.Uponorpro.com)for SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. -- CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE ' more information on Flow Test Setup,Assembly,Performing the Test and PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40oF WILL BE MAINTAINED. - --- - ---- - -- Troubleshooting. If there are any questions please contact Uponor. 80 psi © UPONOR - CONFIDENTIAL FO 0 1 PRV Set Pressure