Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
• c{tv.los• � Markup Legend 1-1/4"AQUAPEX f' v+ SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 z 0 - - - 11 K=4.9,162F°,7/16"Orifice,Maximum Spacing 16'x16' CURRENT STATIC TO SYSTEM '�y S.1 f o Delete Line Sprinkler head demand: 13gpm @ 7.04 WATER PRESSURE TO HOT WATER RC-RES-16 p HEATER O STATIC: 105psi ..z Add Line — — — — — SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 1 1/4"AQUAPEX RISER J 0 s ® - - - 1 K=4.9,162F°,7/16"Orifice,Maximum Spacing 18'x18' -_ ®° ''I' RC-RES-18 Sprinkler head demand: 17 gpm @ 12 PRESSURE GAUGE O 'a ,w N Add Tee I 1 1/4"PRV CASH ACME O (OR EQUIVALENT) ;LL w mo T SENJU Model RC-RE5175 Residential Flat Concealed Pendent SS8464 1"WATER METER ADDITIONAL 5GPM AT TEE 6PSI LOSS FLOWING 26 GPM u.a m z Add Elbow 0 - - - 1 K=4.9,205E°,7/16"Orifice,Maximum Spacing 12'x12' NFPA 13D STANDARD LOSS FOR SHARED SUPPLY FOR Q >°„�'ry Z 2 RC-RES-12-205 Sprinkler head demand: 13 gpm @ 7.04 6PSI LOSS FLOWING 36GPM OTHER UNITS 3/4" NG 26GPMER In ^7 Add Coupling H 14PSI LOSS FLOWING PR,/Set psi •m,m J 3 MOST HYDRAULICALLY REMOTE HEADS @ Z< •« 13 1st Floor CURB STOP Vl�^mm<m t I , SHUT OFF VALVE W'4 Z m 13 TOTAL HEAD# GPM PRESSURE REQ'D AT STREET 1PSI Loss euv-,or o v, Add Head 3- STREET — ILA 'I I I 1 HEAD H.4 17 66.06 a=i Lii I u=3=1 z 1 2 HEAD H.7&H.2 26.0262 91.97 _ ni` z2 <0o 2�, Delete Head -(X 1- CORPORATION -- o y z z ' STOP IPSI LOSS ty - �: :� ' > FlCxcim�5 zSz go Move Head - 00 O- -O- WATER (�• --ail:• ® ® � NQy><�'czUoi �� _ // a =°goiomh • • I I MAIN Q •�. Eu_v=ss' 50'OF % RECEIVED �pi �Z V�ygy om� Note:All revisions must be reviewed by Uponor nev.9s E®5' 1 1/2"AQUAPEX 50'QOF ■�•�E C E I E D z , m -a~,a Table F002-1 10'OF 25'OF 1 1/4"AQUAPEX s l U o 10 0 g'•,,e R z r. 1"COPPER-K 1"COPPER-K ��z y>o - F=- MultipurposeFireSafetySystems S�Somti mot ,- The Uponor Residential Fire Safety System is a residential fire protections •� `/A\, NOV9 ��� o z z6' o o system installed in combination the cold side of the domestic potable 3 ••AT E RSERVICE D ce,o m N°->N o 3 water system. Only licensed contractors trained by Uponor can install this g e i °c- <,• a w F100 w aoa". � E<g system. NTS CITY OF TIGARD 5 tz�N <° 5rioo What to do if Changes are Required H z<h I I I p c S r u If any features or obstructions require the addition or deletion of sprinkler 9 ,."-"r __ BUILDING DIVISION Q I.2'II o 0-u a 6 U 4) ' heads,or significant relocation of sprinkler heads,contact the Uponor Design n °w r�>^ °w>„�^ �-".-". __--. -__.. r-g o U y� Department to determine if observed changes require a redesign �o� a o ••; -t• �3aaaaaaaw • a z F o c d-2 F P 9 q 9 �� 6-0SGD 6-0SGD (888.594.7726). : S&P z 3�,m z EGRESS r- EGRESS xf o-L]` �a�oeO _ DOOR SLIDE DOOR SLIDE - EW L,F u_g,t o h o ff ' ' / / / /, 3000 of >°ma�< r 1� — 2'2Y 1 1 1 22Y' — pppzm�oH N��o R/ J / J i J 5 Nmmmcgu0< <y0'COLD LINETYPE LEGEND I rw=y 9 BLUE UNES=FEED TO FIXTURES(BATH,SHOWER,ETC.). \ ® °t m iW C ' / \ � �>> m �6ohm W.I.C. m TYP.AT I u'R .,,D "mzz< GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. , 0 INT. IM. Bedroom \ '�>P>l; c'm!soRo2 BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. I M. Bedroom z mo ax Hyd s WALL �>��xo <o" xw �,� = 1/2"PIPE SIZE l -...�'� - ; „ , Vii.dj iLivi z IlB P� U.N.O. r \ / ;y�Pu 6,9z Ft . �,.� =3/4"PIPE SIZE C 3'-B' 6 ` It 3•aY2 1�= : "� ,�. •i 11 L 11.2 � r'1•`}� e•-�-rti-.o 3'dY' ■•,S•2 s•.r m I� y�y;i RES 16 (221000A) RC RES 16 RC RES 16 (221000AR) RC RESr16 ,>> ji�� 5 „ , • a —- = 1"PIPE SIZE txx — = 1-1/4"PIPE SIZE ' INSULATE FLOOR _ INSULATE FLOOR T'1 ` s— iI �a" �- OVER CRA DACE I _ I OVER CRAWLSPACE H 5 SH.\ [here by certify[ha[this plan,specification, p� /�L 111161/..„„„ or report was prepared by me or under my S SHELVES � I� —•, - ‘ir ©' 1II // ri1B S SHELVES direct supervision and that I am NICET _ _ -6y' 5'-73/4 �QWT-3Y• � T-'�4` 2•-Z{'2'�2'-8' , 2'-8'� �' 7�-}3�4 � � 7•'3y° �/ 5'-7�4/ " 3.-0� • _ I Certified. SPRINKLER SYMBOL DEFINITION , ■ - 1-6 Hcw T "%6 Hcwso ?v i e i i i �' 1 i i 1.0 osald vim 10 1 I' RC-RE-'. B4 x 60 . R• 'ES-1so . i � � b RC-RE• 16 r 34 x6o I' ��RES-16 O• XXX-XX � IIII _ � __ � !i •' Tlm W McDonald Date: 08/12/2021 I�="vY• SHOWPi t r Illr >• II —IIISHOWER • • � NICET Certification No.150393MAXIMUM SPACING(TYP) 11rv ' . 11��++++ 111 _ -�) Tv❑ Water-Based S stems La ouf-Level III 7 `/� � t J - - •• • j 1_ r Certification Expires:]une 1,2022 �41� _ - 3-06-0SN 3-0 5-0 SH HEAD SYMBOL(TYP) 1 °>j'. - -- •i ' a.1 I•f _ F.1 F.2 =' iiii I° etc RF,�1 •.e is — - — RG-REs-isc F. T' 1 Kitchen © © •I''4' K chgn < I :>'' f TYP. 3 V/ / �, Porch _ Porch N � r I m t, W i Bedroom 2 K i Inn"_ 5 16 1 "Bedroom 2� X w 1 `■t' i jam[I m H 10 L� S SHELVES 'L ! ' R ri I vfat�. H.10 /iII �y, " R S-1 i. Y-,* r r 3,10)i• Ai G °ray B. h abslw o Ate' m 14 r-rye , -'_ j> ^ gq��� Pi '• ltiff►'�,� "`T 8• --wj IT-0' I I. it-0• ' 7-8'" S> 2-6 HCW I Mt F— a ta'!v�i n o.P�. g ii T 1� WIN '�, ��. rj °' 1 \� (�iZrl,T��7 0 1-1/4"AQUAPEX TO (�' ';I " " 6` / "�' o W / R .1„,,,,, 2-e HCW / •\ �.- A�' �'•— 1-1/4"AQUAPEX 70 Q f ■ --j tl u SYSTEM / I +18°ABOVE SLAB - - rv� _ .18'ABOVE SLAB---y R SYSTEM Q J O .' WASHER -_■ Den/Bdr 3 DDi/Bdrm 3 DRYER WASHES S•1BOLLARD i i :• d i Z r a S'TUB k , A O f J BOLLARD S.i rz G tj a g t_ MAIN SHUTOFF rh...wie ` f ■ � 1 \ m '" •■.,. _- ' 1 MAIN SHUTOFF t a a z o 2-8 1NSUL i' S 2-B INSUL F-a VALVE LOCATION ��__-- � • -d VALVE LOCATION , zi h' /13 0 ' t:��, `.,. J ® f-1F-�I - © U W O u u a m N o i , 'r ,r �:ME,.II 1 I ea, F IR SIM. It wlli I'tv� J W °t SIM. SIM. I F 'I I tor• F /E Stor. i SLi SIM. SIM. a m CITY OF TIGARD © ,I - -- ' ' ' garApproved [)C] 1'fi' S'3)4 di 3'-1tv. 3'-0)• `.�. P 6Y2 Y 4 S-3)4 6'-K' 4'-6' W O o z ri 0. PLATFORM AT � PLATFORM AT I . O Contitionally Approved [ l ADUsFu PLATFORM `,�` f+18"ABOVE SLAB SFU z.6 ADU Y f f B O Z f P For only the work as describ�d in: Garage Garage Garage Garage w y Z WH J w U PERMIT NO. 1 Ic - o ►) I ® __ ..[ , S&P aF r m a See Letter to: Follow _ m W ►� 7 �� - � cnlwK Attach zxa iILhMING® °C. f ca..; %,e N t 2x8 FRAMING• a O U‘is fy vi z ELEOENTRANCE E 1�^ O I ELEC.ENTRANCE Job Address: / 0 .SW TYIIU I Vtw� �e'� Siu , � t ���! ry/ "A.,, (� SHEET DESCRIPTION FIRST FLOOR W/MIRROR By: ,4Gli, Date: f�f,s/91 1 FIRST FLOOR CD FIRST FLOOR — MIRROR • F100 1/4n = 1t_On 1/4 = 1 -� SHEET NUMBER n t n =M11011 F100 5 0 5 15 t--� t 1/4"=1`°" © UPONOR - CONFIDENTIAL r ` •AquaSAFE GENERAL NOTES: Senju RC-RES:Open Web Truss/TM Construction Insulation Recommendations N TMSee General Notes 8.2.5.8 for Architectural In areas subject to freezing,care should be taken in unheated attic spaces ^' ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements me Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor ` f g 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2019 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Blocking Maybe Fire Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guidllnes"for attic Y O SECTION 3.3.12.3. - - - on Nut Required.If - installation guidelines(Provided in Contractors Documents package or online el - d Blocking is Used, Y• ' 1 Min at www.Uponorpro.com). r j a z 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON .� I/a" Use The 2Top w^n THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND r�l I 1 "Max. f UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. Screw Holes. 1 Ir JI 6C / Bottom of Mounting Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. O _ L.�f ' racket to Face of Truss AquaSAFE Residential Fire Safety systems are often installed in attics or If no additinal floor area is created No Additional Sprinkler is Required. Q P e'Q 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter - other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less O u RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket -,- the recommended extreme weather installation instructions to isolate and / > PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE I � �-- protect system components from extreme temperatures. Because this RC-RES-i6.1 °E t a w O SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE /� O w u!z SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 11/2 system also delivers domestic cold water directly to plumbing fixtures, ® w e z a�y Q 9'-0°or less >h n } Uponor highly recommends that you protect the tubing with adequate / 4' E ¢ti^t?? Full Course -1-� �--t insulation in warm weather areas to minimize heating of the cold water N£d w 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Si rews V ism C-1 e ° = Z v o 3 NFPA 13D 2019 EDITION. In Button'Holes supply, o y O-.ao w 3 m 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE PERMITTED TO ONLY USE ANTI-FREEZE '� - - \ Installation methods include,but are not limited to: F.t, 0° W rn c°Do Z w LISTED FOR USE IN NEW SPRINKLER SYSTEMS. IDy - - • Tenting over the fire sprinkler piping. O m~m 3 Lead-Free Plat, �P', •'y • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ftt,be more than 2'-0" 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Concealed Senju \ Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0°wide and be with in the coverage area of the f a d 5. d DAMAGED MUST BE REPLACED. Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. o- ROE z ? a Eg zooR Caution: If you will be installing spray foam insulation,make sure to h m iV 7. A SINGLE CONTROL VALVE ARRANGED TO SHUT OFF BOTH THE DOMESTIC SYSTEM AND THE SPRINKLER protect all components during application.Consult with the spray foam g x <�°N o m Id SYSTEM SHALL BE INSTALLED. Senju RC-RES:Traditional Wood Framing Construction manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.6.3 Distances From u 6 yo ocz<o z Heat Sources uu°too<o0 g4ma 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. o z z a m i� Consultation with local building officials is encouraged to ensure compliance iIL i#w o with local building codes. i p a c 2 2 z u 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING:THE ProPEX LF Brass Fire Fire Sprinkler Adapter Ordinary Intermediate S:C o G a u 2?0.3, z PRESSURES TO FIGHT AWATER SYSTEM FOR IS HOME SUPPLIES FIRE FIRE DEVICES THAT RESTRICT THE THAT FLOWOR DUIRE CERTAIN FLOWS AND ECREASE THE PRESSURE OR Sprinkler Adapter Tee Heat Source Temp. Temp. d re�d }p N Fd "'i-z Push on Nut o 0 - 135°470" 175"-225" z•. m a o n' : o AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, BendingPEX Tubingit ❑ i m a- =C FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM I-I /j Side of Fireplace 36" 12" o y o o a g o a< 1 I/a'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times 7•m �, E c f,tz 3,1 WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVELEJ Front of Fireplace 60" 36" W m❑m v,>u,42 z THIS SIGN". 1 Y2'Max. the outside diameter(6 x OD). o o -a a ° Bottom of Mounting Wood Burning Stove 42" 12" M 2 a o a i t yr m,1 v,C 9 Fire der Adapter Bracket to°ace of Truss Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX 18" 9" a F r,o z z o o F f ran>3 z 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. Mounting Bracket tubing to facilitate 90-degree rigid bends. Kitchen Range z a-o o F a f E o uhF- dda 1 Wall Oven 18" 9" U a E M-ic i �u 5 < 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. 2-#10 x 1 1/2" . Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" VI 0 u o 7d c2i c ° <i;uu-, w ay6 Full Course ° a u ti 1 -F t }' Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" D m o z u y y 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING Thread Strews t,----.�1 �E F c z F N d c o; BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE In TopHolesdUninsulated Hot Water Pipes 12" 6" RESTRICTIVE SPACING LIMITATIONS. �L.y 3/8"ProPEX Fitting 2" z 'z 1/2"ProPEX Fitting 2" Side of Hot Air Diffuser 24"36" 12" z a hq o i y u g u o,z 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING - - \ Front of Hot Air Diffuser 36" 18" 3 c m d a s i m m a - 3/4"ProPEX Fitting 3" Hot Water Heater 6" 3" ad z o`m u° v,?" MOUNTED OBSTRUCTIONS. Lead-Free'Flat c 1°m z h o v,i B Concealed Senju . \. 'r" , } 1"ProPEX Fitting 3 1/2" Furnace 6" 3" p o a m �> 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Sprinkler Head Concealed Flat SOW-250W Ught Fixture 6" 3" g �i a umi °� z ro D Cover Plate -1 1/4"ProPEX Fitting 4 1/2" g o €2 o 2 m SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. 9 u �i E 3 5I ,z z a a 250W-499W Light Fixture 12' 6" u 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN \ w o 4 p 6 o u o'S m S a w CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS Exposed Installation Requirements. y u u u a F c `a e THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. Uponor Aqua PEXTM '"'tubing(white)and ProPEX EP Fittings and ProPEX'"t \ II lot 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Brass Fittings are approved for exposed installation where the following • 8.2.5.7* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS conditions are met.(UL 1821 Approved) THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT.PER SPRINKLER. - m /p)gill • 8.2.5.8 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY Exposed Wood Joist Ceiling Assemblies. o _ n I here by certify that this plan,specification, WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: 1. Joists are of dimensional lumber,engineered wood or wood I-joist. "' or report was prepared by me or under my (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO 2. Joist are of depths from 6-16 inches(152-204 mm). //- m direct supervision and that I am NICET ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 3. Joist are of spacing from 12-24 inches(305-610 nun)on center. (/ ❑ Certified. (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL 4. Joists can be exposed after installation. SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center \ i T (/,:y� (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT'(1.7 Mt) are used. 1.55" 1.66" 08/12/2021 (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 24 INCHES IN DEPTH AT THE DEEPEST POINT OF 6. Listed residential automatic sprinklers of maximum activation 4. Tim W McDonald Date: THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED temperature rating of 155°F(68°C). in-in Hanger 1" Hanger NICET Certification No.150393 ALONG THE FINISHED FLOOR. Water-Based Systems Layout-Level III (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE PLANE OF THE PRIMARY WALL. Tubing Support Spacing: Certification Expires:June 1,2022 Metal Tubing Support. (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. 1. Metal tubing supports designed ma plastic tubing shallp ct used. Enough to Allow the Tubing to Expand and Contract) (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 2. supportsDo not user supports that will damage the tubing.Inspect metal ARCHITECTURAL FEATURE. Do for sharp o ges. 1. Along Horizontal Runs,Install Supports Every 32",at if -Foot Intervals. Runs are 3. Do not rigidly anchor Uponor AquaPEX tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each ata Mid-story e.Guid • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 Floor andLLJ 0 z THROUGH 8.3.8. iii • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT'(5.1 M')AND LESS In-line Flow Test x f w • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THATa F m „ EQ The In-line Flow Test can be constructed on site. It performs a flow test to O� o W MEET ALL OF THE FOLLOWING CONDITIONS: High Upstream Pressure ensure proper system operation and flow(see Figure FO01-8). r o (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 MT). If the upstream pressure exceeds 80 psi a pressure reducing valve may - z z^ .- a (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE need to be installed. Some jurisdictions may require a pressure reducing Cl-I a>m e MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. valve regardless of upstream pressure. 4ngj nor AquaPEX H� a<°,""„c ti • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND SIMILAR STRUCTURES • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSEEQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, - -CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING '• 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR8.3.5.1.2. L-- o a x ur 8 • 8.3.5.1.1 WHERETHEFUEL-FIREDEQUIPMENTISABOVEALLOFTHEOCCUPIEDAREASOFTHEDWELLING �� X U U u¢a.mMaleThreadedCoupling UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. v• 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE Sprinkler Adapter rn DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE `1"Ball Valve a INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED - -To Hot Water Heater Male Threaded Coupling EQUIPMENT FROM THE OCCUPIED SPACE. w v Female Threaded z • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN UNHEATED ENCLOSURES AT THE BUILDING AT _ E Tee with Water 0 •+- a o ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER ENTRANCE/EXIT. Pressure Gauge a: • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING '" Sprinkler Orifice �^^�� 0 z i �" Pressure Gauge P (Optional) c f O CONDITIONS: m m - L- j o Q O w, (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED m `e I� III 80�,-�,rn 100 FT.(2.83 Ma). 3 eo (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS . Flow Test .•./ M f g ry AT THE LOWER CEILING ELEVATION. ;Pi, To ensure the system provides enough water for proper fire sprinkler LL C I-u (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE E, performance,you should conduct a flow verification test. W U Q w w Uponor Warning Signs �rr'tI -E z t '- TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. Y m Note: The NFPA 13D Installation Standard does not require flow < V =m w _LL O (4)SKYLIGHTS NOT EXCEEDING 32 FTz(2.97 Mz)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. c verification. • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS m ~� 1--i z><5 F u Pressure Reducingw ri a: (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR v7 Before performing a flow verification test,confirm the water pressures by p ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED - z � ', Valve contacting the Water and Sewer Department of your local city. Ensure the -o u tt N a PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. o available water pressure matches the pressure used in the system design. • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING is a SHEET DESCRIPTION EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. U m Note: The sprinkler plan Indicates the most hydraulically remote sprinkler Li Main Fire Sprinkler (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS 18. INSULATION GUIDE LINES PER NFPA 13D. a Shut-off Valve your local code. • 9.1.1*WET PIPE SYSTEMS. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE USED WHERE ALL PIPING IS INSTALLED IN AREAS NOT SUBJECT TO FREEZING,INCLUDING AREAS PROPERLY INSULATED TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to MAINTAIN 40.F. , performing a flow verification test.This may speed up the inspection •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO process and eliminate the need to repeat the test for the inspector. SHEET NUMBER COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE iNote: See"AquaSAFE Flow Test Instruction Sheet"(Provided in GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) ' Contractors Documents package or online at www.Uponorpro.com)for SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. '--"- -- more information on Flow Test Setup,Assembly,Performing the Test and CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE L . i- Troubleshooting. If there are anyquestions please contact Uponor. PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. 80 psi © UPONOR - CONFIDENTIAL FOO1 PRV Set Pressure