Plans
a Markup Legend Residential Flat Concealed Pendent 558464 1-1/4"AQUAPEX /' E�vto SENJU Model RC-RES ' 0 - - - 11 K=4.9, 162F°,7/16"Orifice,Maximum Spacing 16'x16' CURRENT STATIC TO SYSTEM 'x:r - S.1 % z o Li Delete ne Sprinkler head demand: 13gpm @ 7.04 WATER PRESSURE TO HOT WATER w u RC RES 16 P HEATER O u STATIC: 105psi _ O Add Une — — — — — SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 1 1/4"AQUAPEX RISER - a n 2 g 0 - - - 1 K=4.9,162F°,7/16"Orifice,Maximum Spacing 18'x18' � �° Sprinkler head demand: 17gpm @ 12 PRESSURE GAUGE '¢a w i T RC-RES-18 P O m Add Tee I I I 1 1/4(PRV CASH ACME O wQ,> ' T SENJU Model RC-RES175 Residential Flat Concealed Pendent 558464 (OR EQUIVALENT) m;u•w 2O Add Elbow - - K=4.9,205E°,7/16"Orifice,Maximum Spacing 12'x12' 1"WATER METER ADDITIONAL SGPM AT TEE 6PSI LOSS FLOWING 26 GPM g u y Vi z 0 — 1 P 9NFPA 13D STANDARD LOSS FOR SHARED SUPPLY FOR Q i j y N z g RC RES 12 205 Sprinkler head demand: 13 gpm @ 7.04 6PSI LOSS FLOWING 36GPM OTHER UNITS 3/4"SUBMETER BOpsl W"�y Add Coupling H 14P51 LOSS FLOWING 26GPM—�"- /-�--�.� PRV Set Pressure ra£a w 13 1st Floor MOST HYDRAULICALLY REMOTE HEADS CURB STOP °j 3 I , I SHUT OFF VALVE `: `�\ `®` `�` 13 TOTAL HEAD# GPM PRESSURE REQ'D AT STREET 1PSI LOSS - • ELEV-tar p e,4251 Add Head - 1-- - 3- : 1 HEAD H.4 17 66.06 STREET I Tilli i Delete Head X-X_ 2 HEAD H.7&H.2 26.0262 91.97 CORPORATION RNLI o x °' o .2. 'a _ 'Y a d STOP 1PSI LOSS r.,. '•a- _ y y g o o o Move Head -O�_`O- WATER (.�y�..•I •� R �E //�•�' u� '5' °°i,-ozaueu • • • MAIN DECEIVED v�2 F.a ym��>pz Org I • I © ... ELEV=95' SO'DF uE ar.r..z.-g ,);< I 1 1/2"AQUAPEX 50'OF C m Note:All revisions must be reviewed by Uponor eu�-es Q m p f�m���ou 11/4"A AQUAPEX Uoy� I-S`-•4c' ya Table FOO2-1 10'OF 25'OF Q ?_moo.'U � 1"COPPER-K 1"COPPER-K NOVdmzv.>o 2d� � Cn Multipurpose Fire Safety Systems y 9 2021 z°olmaiBio .o r ) The Uponor Residential Fire Safe System is a residential fire protections o° z o o `rJ system nstalled in combination Safety the cold side of the domestic potable 3 WATER SERVICE DETAIL W m Ei G c g g F z 3 a water system. Only licensed contractors trained by Uponor can install this CITY OF TIGAR[ ,-u0 u�a Z 20 a w a a� - system. M<FOZZ OOffa�3z _10ee" NTSr'� 1`1�°;�g1IP'1 F What to do if Changes are Required DIVISION y zyEl' o4 '61 y6 If any features or obstructions require the addition or deletion of sprinkler fy m e d d h d 0 heads,or significant relocation of sprinkler heads,contact the Uponor Design ; N •-v°•••'^ '-°°"°'^ '"'O-V` '""-"' I • ----- ----- I _ _ �-'.:BUILDING 8°1 i°'o% u y z z s: �F ram_ Department to determine if observed changes require a redesign •"I 6U SGD 6-0 SGD ®� Z c z m r e o a , (888.594.7726). EGRESS S&P S&P EGRESS , � z t 3 r, h z u 5,i? /_ --'-1, -. ��DOOR DOOR v ,� ';�� u�idgam<�a — \ 2'Z ' ./ I I l 1 2' — \ o6o1'mo8„oVyow COLOR LINETYPE LEGEND L I >w �°<"_"� / � � J J .i J i;��mo se � BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). / W C e ® ® * w i C \ / a3y>>*1H �oym INTERLEVEL CONNECTIONS/SUPPLY. , TYP.)QT CV Ur m TY AT \ o BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. I M.Bedroom \ INT. INT. / IM. Bedroom „;Fjy3EtiF`1-1c6E`-' WALL :111:2.f .''' WALL ��. o 8s ." "�u� = 1/2"PIPE SIZE \ . '1 U.N.O. - V.In �JVI ' - 1 U.N.O. .�. \ ! I-.,Huuub�Fc `a�c— 3 4"PIPE SIZE 3-9 � 3'3Y2' l• , Fit1. •`Y ----� 3.3Y` •, Yz' N / n ►t � yy : • R�R (221000A)V RC-RES-16 RC-RES-16 r(221000AR) RC RES 16 N-6, —I— = 1"PIPE SIZE I. s = 1-1/4"PIPE SIZE 1 1'1 S SH. INSULATE FLOOR INSULATE FLOOR 5 SNil' h —W. I F- OVER CRA DACE I r I '�OV CRAWLSPACE • -- c \ \ ' l I here by certify that this plan,specification, -fait ,s ©, 1 1 \ ,. 1 \ or report was prepared by me or under my 5 SHELVES � ` ? I 5 SHELVES I direct supervision and that I am NICET •fi • 5'-73/4 \QP T-3}• \ 7-•34. ='y2•.�2'-a' 2-a• 7`�4 7-3Y '_� 5'-T�4 / 3'-6�r Certified. SPRINKLER SYMBOL DEFINITION rI a • t-6Hcw m M ,-6Hcw • ED xxx xx O RC-RE v � • ', " 'ES-16 RC RE• 16" y�60 ' 'RES16 II �.���+?�t[1'er..,C/�_ AO Tim W McDonald Dale: OS/12/2021 iR i y 1 �� !at. frim r' �� 1 :ROWER ~• NICET Certification No.150393 MAXIMUM SPACING(TYP) l)rP I ��1 I ) �m p Water-Based Systems Layout-Level III SPRINKLER MODEL(TYP) "_'�- � J - 11, � jl III i 14 �� Certification Expires:June 1,2022 HEAD SYMBOL(TYP) fr:� ►1 RG 1 , '• 3-0 5-0SH I 3-05-0 5H ,-�1 p N �.1•6,, �' F 1 l ',,t:, \ ' Kitch n .' p— — © K}tch n 1 >� I F. . In 17 1 ti. KW X7 ,, a/ m i s N Porch Porch Ti` m 0 µ�� 111111111 .41m., 11 1 c__-- r y` n N i - 4 \ ;III, Wz I &P - - .......•. S& I I m Bedroom 2K �� rBedroom 2/ X W 5 SHELVES r� 5 SHELVES 111 \ L� O' ,',o0 W -" mlI RC41ES•1. 3'1We 1 1 3'-,oy " 1 1: 40BIFOu II � 1V Q j M p oII�� I� II B th B. h I� I .{ _1 a) m 0. \,� 7'-8• —/w „•-o' II 1 L,1 N „•-0' iia. 7'-e'.. � 5'7 z' \-F.1 122 49 1—� <ci7 u�i ry c.. 1-1/4"AQUAPEX TO , 'PLAT • L4 1i \—It;�__ _'� �--F o W [Q• �il,•�1 �i + '�S�•'12 E1 .. �,.._ w 19 _ _� i 6 \ ` ` R:-_-_ AY" ' 1-1/4"AQUAPIX TO 0 s SYSTEMa18"ABOVE SLAB - - �ie, � - � ��- - +18'ABOVE SLAB SYSTEM DRYER WISHER '+tea-=� Den/Bdr1�i 3 DDi/Bdrm 3 _'i DRYER WASHER I ' Q g O i • BOLLARD 1 1 TUB& u -� d a ! c"l6 oi l BOLLARD--.-0 i F S.1 MAIN SHUTOFF 1P1111-"°1111 2-81 NSU1 1 .� 1 ti 9� t S•1 MAIN SHUTOFF 1 a¢ z o N t5 �J R m VALVE LOCATION f D/ _ \ -AI 2-B INSUL VALVE LOCATION F z ~O r`w' . vwa. _Lr `.a C. sse: i L li d -J Wx SSg<a.z r lap } Q J Le' '' e e /I fRrcIE i i SIM \-i { SIM. I11,3n INS�I�,,y 1 ry� X'f 8 DI ,� W InCITY OF TIGARD 11 SIM. SIM. ,„ '4og l i tor. Stor• L U I SIM. SIM. f' IZ c Approved Ilk t; I I I L ---- ( I I I I ►, LL = Q Contitionall Approved [▪ X] Mr 0, 5'3r 3'-„Y 3'.,,YZ_ ,.� ,6Y` r 5-3r 5.0 4'-6• `+ e w O s a E H D = 1' I A PLATFORM AT PLATFORM AT y, ►' \ c z 'm ro For only the work as describ: . in: ADu sFu Tn 18'ABOVESAB +1a ABOVE sFu P ADU Y e< o PERMIT NO. 6 �� _ w _.� f w NtSTa?O2 1— 1�0 y/2" i Garage n Garage Garage ,+ ; Garage See Letter to: Follow •••[ ] .,-,1 6, J 5&P 6 > Q Q W> moo 0 Attach • [ j ,1 e �® ® _� ce v~) 1—' o w s< Job Address: r66 AO SW • -8 INN@ ELEC�ENTIRANC@E d u U N z ^ ! Tom,Ai r .rRANCE ► t) 1 ti° 1; By: /"fL� Date: ► ° ,.I SHEET DESCRIPTION J ��/Z1 ►, jury\ ��� � , ��� /� ►+ FIRST FLOORW/MIRROR 1 FIRST FLOOR FIRST FLOOR — MIRROR I F100 1/411 _ 11_0" Ci 00 1/4" - 1'-0" SHEET NUMBER 5 0 5 15 1/4"=1'-°" © UPONOR - CONFIDENTIAL F100 a Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations See General Notes 8.2.5.8 for Architectural .AquaSAFETM GENERAL NOTES: In areas subject to freezing,care should be taken in unheated attic spaces ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor T ` z 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2019 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Blocking Maybe //1-Fire Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic /�y W SECTION 3.3.12.3. �C J Pgsron Nu[ Y////// 0 Required.If S/ installation guidelines(Provided in Contractors Documents package or online 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, at www.Uponorpro.com). _ J 0 1]q"Min. ! l Q.,Z Use The2Top w^a THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND I ` I �7 - I 1 I/'Max. S Screw Holes. ■I Ir JI■ Planter Box Window,Bay Window or Similar Feature. C ¢ -"O UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. r Bottom t°ram of Extreme Temperature Installations If no additinal Floor area is created No Additional Sprinkler is Required. i a m I ' AquaSAFE Residential Fire Safety systems are often installed in attics or ¢o,w a 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adayte �� other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less 0 { m N 0 RESPONSIBIUTY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE MountingBracket the recommended extreme weather installation instructions to isolate and / ° m> PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE � �--- I 1 .6r:s.w O r protect system components from extreme temperatures. Because this RC -16 N z SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE 0 SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#30 x 1 1/2" + system also delivers domestic cold water directly to plumbing fixtures, e i a© 9'-0"or less 4 N >b n _ } Uponor highly recommends that you protect the tubing with adequate / w C m L7? Full Course i I - w 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH �-f insulation in warm weather areas to minimize heating of the cold water m o t N 5 g w 3 NFPA 13D 2019 EDITION. In Bottom Holes U o_ o = j tZ7 p'^. 3 supply. m 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE PERMITTED TO ONLY USE ANTI-FREEZE - \ Installation methods include,but are not limited to: n`o m W m m Y m LISTED FOR USE IN NEW SPRINKLER SYSTEMS. 0 y E. • Tenting over the fire sprinkler piping. O v'f w 3 Lead-Free oat.- E. • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft',be more than 2'-0" 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Concealed SenJu ` '"� -f Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the a o m Sprinkler Head o -m DAMAGED MUST BE REPLACED. Cover Plate sprinkler.No Additional Sprinkler is Required. o y i x z r Caution: If you will be installing spray foam insulation,make sure to ur y z 9 z a 6 o y E 7. A SINGLE CONTROL VALVE ARRANGED TO SHUT OFF BOTH THE DOMESTIC SYSTEM AND THE SPRINKLER a m p o=-i'o s SYSTEM SHALL BE INSTALLED. Senju RC-RES:Traditional Wood Framing Construction protect all components during application.Consult with the spray foam F o c o m o manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.6.3 Distances From 2 H h<5 .a m m z o z Heat Sources zFia �,. 2 a 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. u�i 0 o 0 o s, w Consultation with local building officials is encouraged to ensure compliance f m m o 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING:THE ProPEX LF Brass Fire 48 with local building codes. ci p a o m of a u i o 3 Q Ordinary Intermediate _V1 W WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Sprinkler Adapter Tee Fire Sprinkler Adapter Heat Source Temp. Temp. arac 0 o y cop°G 5d 9 c-8 PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT HE FLOW OR DECREASE THE PRESSURE OR \ Push-on Nut 135°-170° 175°-225° z ^ `�iv d o AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, `-`' BendingPEX Tubing8 cz,a`o c c as 2 o =€ FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM - Side of Fireplace 36" 12' _p z WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE } 1 1/q'Min. The minimum bend radius of Uponor PEX tubing In any direction is six times Front of Fireplace 60" 36 W m o m�>y zz o z THIS SIGN". �, i 1/z Max. the outside diameter(6 x OD). p o ,a a Bottom<f mounting Wood Burning Stove 42" 12" N a o-.#,-y "z g= Fire Sprin der Adapter .1 Bracket to-ace of Truss Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX 18" 9" Q%t_c o z z o o F a>3 z 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. Mounting Bracket tubing to facilitate 90-degree rigid bends. Kitchen Range .d u G F o F rig i 3_o g n Wall Oven 19" 9" U A.z.." a 'El'5l €"a 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. 2-#10 x 1 1/2" 0*-1 v Recommended Tubing Length Between Fittings Hot Air Flues _ 16" 9" to czi Q 2 g 4p4 B c z 5_98 Full Course I2_f f - } Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" G m z o b F u o b o z`a`2 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING Thread Screws 1 L�r �T E.. u., p d.t o BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE In Top Ho es t> tl--U CJ 3/8"ProPEX Fitting 2" Uninsulated Hot Water Pipes 12' 6" y9 F p g t N z U Q a o RESTRICTIVE SPACING LIMITATIONS. Side of Hot Air Diffuser 24" 12" o a 0 p w r o u p 1/2"ProPEX Fitting 2" Z .y a w°m V 7=..1 z z 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING - Front of Hot Air Diffuser 36" 16" 3 p z 8 m 5 a m z i uai o aw �J' . 3/4"ProPEX Fitting 3" Hot Water Heater 6" 3" z o°i<u o 0 MOUNTED OBSTRUCTIONS. Lead-Free�FIaE.-- - -- p m o i o m p" c- o Concealed Senju - N. 'r" r'' l- 1"ProPEX Fitting 3 1/2" Furnace 6" 3" o,.: m o.".,u�' .2',. o 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Sprinkler Head Concealed Fla[ SOW-250W Light Fixture 6" 3" w c 8 m.-z :C=°�z m- Cover Plate 1 1/4'ProPEX Fitting 4 1 2' g > °' m SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. g / 250W-499W Ught Fixture 12" 6" y u �i °g a m"z z u w 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN m L z r-s p'ap m w CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS Exposed Installation Requirements. y N THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. \Uponor AquaPEXTM tubing(white)and ProPEXTM EP Fittings and ProPEXTM II rA 16. NFPA 13D 8.2.5•OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Brass Fittings are approved for exposed installation where the following • 8.2.5.7. SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS conditions are met.(UL 1821 Approved) to THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT.PER SPRINKLER. rl r' ' 7 8.2.5.8 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY Exposed Wood Joist Ceiling Assemblies. o n I here by certify that this plan,specification, WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: 1. Joists are of dimensional lumber,engineered wood or wood I-joist. "' I mor report was prepared by me or under my (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO 2. Joist are of depths from 6-16 inches(152-204 mm). m direct supervision and that I am NICET ADDITIONAL SPRINKLER PROTEC ION IS REQUIRED. 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. Certified. (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL 4. Joists can be exposed after installation. ❑ SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center ' (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT°(1.7 Mz) are used. 1.55" 4, \ 1.66' �. (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 24 INCHES IN DEPTHAT THE DEEPEST POINT OF 6. Listed residential automatic sprinklers of maximum activation Tim W McDonald Date: 08/12/2021 THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED temperature rating of 1550F(680C). i" -i" Hanger 1" Hanger NICET Certification No.150393 ALONG THE FINISHED FLOOR. Water-Based Systems Layout-Level III (c)THE FLOOR SHALL NOT BE GREATER THAN BET IN LENGTH WHERE MEASURED ALONG THE PLANE OF THE PRIMARY WALL. Tubing Support Spacing: Certification Expires:June 1,2022 (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER Metal Tubing Support. (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. 1. Metal tubing supports designed foma plastic tubing Inspectnsll be used. Enough to Allow the Tubing to Expand and Contract) (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 2. supportsDo not use for supports that will damage the tubing. metal ARCHITECTURAL FEATURE. Do sharp or ges. 1. Along Horizontal Runs,Install Supports Every 32",at if -Foot Runs are 3. Do not rigidly anchor Uponor AquaPEX tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 Floor and at a Mid-story Guide. LU z THROUGH 8.3.8. m • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT.(5.1 M.)AND LESS In-line Flow Test >< x w • 6.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT The In-line Flow Test can be constructed on site. It performs a flow test to LU n O e = MEET ALL OF THE FOLLOWING CONDITIONS: High Upstream Pressure ensure proper system operation and flow(see Figure F001-8). i.")F^ n o (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 M.). If the upstream pressure exceeds 80 psi a pressure reducing valve may J z z^ II (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE '^. needlyto be Bless of st ea jurisdictionsesue. may require a pressure reducing I MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. J a o.. valve regardless of upstream pressure. Uponor AquaPEX • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND j Tubing /% a m n SIMILAR STRUCTURES w • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE -1 J Q m EALED SPACES DEDICATED EXCLUSIVELY CRAWEQUIPLtSPAC S,AND OTHER ENT ROOMS, OR MACHINE ROOMS,CONCEALED SPACES THATC ARE NOT USED OR INTENDED FOR LIVING TO AND .• CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, -- -- __ z p w z 5 p PURPOSES. �I''-� z rj V¢an 6 • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL FIRED UIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR �imik I I i a'a O °C 8.3.5.1.2. �'Llc�___1- / Z z G j O w vwi • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING LU X O O o a a a z o UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. Male Threaded Coupling ProPEX Fire ( 1 W O • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE �a,J Sprinkler Adapter U rn DWELLING UNIT,AT I FACT ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE w h''-__ 1. 1"Ball Valve a S INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH HE FUEL-FIRED -To Hot Water Heater Male Threaded Coupling LAB' EQUIPMENT FROM THE OCCUPIED SPACE. '( �` Female Threaded z • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN UNHEATED ENCLOSURES AT THE BUILDING AT m w Tee with Water0 :: ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER ENTRANCE/EXIT. n h �I� pressure Gauge ¢a • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING S rinkler Orifice W CD' ^u �". ' Pressure Gauge P (Optional) CONDITIONS: - a R I ' I- p a o d (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED a `o c z n 100 FT.(2.83 Mn). E Flow Test ��// W r1 a a (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS a 0 1.-C� i'',E f�+ El AT THE LOWER CEILING ELEVATION. E. rn • To ensure the system provides enough water for proper fire sprinklera 1-0.r (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE 2 performance,you should conduct a flow verification test. LU U Q Uponor Warning Signs �r'L c- f F TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. o Note:The NFPA 13D Installation Standard does not require flow > Q V f m m z LL o (4)SKYLIGHTS NOT EXCEEDING 32 FT.(2.97 M.)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. .� verification. I-I> I- w • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS " �' �/ ,^ 1-1 z x g'. (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR F I rY Pressure Reducing LL v' f- 3 w c S a 7.--- Before performing a flow verification test,confirm the water pressures by r= ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED z Valve contacting the Water and Sewer Department of your local city. Ensure the au niusz PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. 8 available water pressure matches the pressure used in the system design. 6 • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING SHEET DESCRIPTION EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. - Note: The sprinkler plan indicates the most hydraulically remote sprinkler 18. INSULATION GUIDE LINES PER NFPA 13D. a ` Main Fire Sprinkler you pair r local co of de rinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS • 9.1.1•WET PIPE SYSTEMS. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE USED WHERE ALL Shut-off Valve PIPING IS INSTALLED IN AREAS NOT SUBJECT TO FREEZING,INCLUDING AREAS PROPERLY INSULATED TO i Note: It is a good Idea to notify the fire inspector at least 24 hours prior to MAINTAIN 400F. performing a flow verification test. This may speed up the inspection •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO I process and eliminate the need to repeat the test for the inspector. SHEET NUMBER COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) 1 Contractors Documents package or online at www.Uponorpro.com)for SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. - more information on Flow Test Setup,Assembly,Performing the Test and CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Troubleshooting. If there are anyquestionsplease contact Uponor. PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 400F WILL BE MAINTAINED. - - -J P 80 psi © UPONOR - CONFIDENTIAL F001 PRV Set Pressure