Permit S' sitiziti+uei�+
go CITY OF TIGARD MASTER PERMIT
I� s. - COMMUNITY DEVELOPMENT Permit#: MST2021-00496
Date Issued: 12/30/2021
Ti i;A R L) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439
Parcel: 2S112BD01000
Jurisdiction: Tigard
Site address: 14558 SW 79TH AVE
Subdivision: Serenus Subdivision Lot:
Project: Serenus, Lot 19
Project Description: New detached dwelling
BUILDING
Floor Areas Required Setbacks Required
Stories: 2 Bedrooms: 3 First: 635 sf Basement: 0 sf Left: 5 Parking Spaces: 0
Height: 21.5 Bathrooms: 3 Second: 987 sf Garage: 390 sf Front: 15 Smoke
Yes
Dwelling Units: 1 Third: 0 sf Right: 5 Detectors:
Total: 1622 sf Value: $231,799.96 Rear: 15
PLUMBING
Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0
Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer 100
Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker 1 Hose Bib: 2 Backwater Value: 1
Other Fixtures: 0
Drywell-Trench Drain: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 4 Clothes Dryers: 1
Natural Gas Heat Pump: N Hoods: 1 Other Units: 0
Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All
Y
Other: N Other Description: Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
NEW SF VB R-3 1622
Owner: Contractor:
BLUE PALOUSE PROPERTIES LLC DR HORTON INC PORTLAND Required Items and Reports(Conditions)
14630 SW 79TH AVE 4380 SW MACADAM AVE SUITE 100 1 Ersn Cntrl 503-639-4175
TIGARD,OR 97224 PORTLAND,OR 97239
PHONE: PHONE: 503-222-4151
FAX: 503-222-1304
Total Fees: $36,179.73
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
oc ..nni-no,n thrniinh nAR Ot9-nn1-n11on Vnii mw nhthin n rnnv of The.rnlec nr direct ni lncti ne to(ll min by r.nfnn Fn'i 949 10R'�7,,n�r�1,R,,n 1R'1)9444
Issued By: Ho{1 j Vaw De �nll g� Permittee Signature: O� AI"f'"u` ^f 1`
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the iob site at the time of each inspection.
Building Permit ApplicationfECEI V E sv I u1 i 2,
. Residential NOVy
CityTigardFOR OFFICE USE ONLY /y1/
of O 20�a ReceiDate/By: 1 0 12 ved I' 2'L•Permit No.: M9- -OCY ICi i,
I/ . 13125 SW Hall Blvd.,Tigard, 223 (;ITY OF TIGARU Plan Review ez n , /�,/� ether Permit: R��t_�'�l'�l�
Phone: 503.718.2439 Fax: 503.598.19 Date/By: U /��
T I G A R l) Inspection Line: 503.639.4175 BUILDING DIVISION Date Ready/By:
i6See Page 2 for
Internet: www.tigard-or.gov otified/MethJO ( I Supplemental Information
"7 I
TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING
121 New construction 0 Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application. gel 1(-741 ` 9
r
❑ 1-and 2-family dwelling 0 Commercial/industrial Valuation: $1 0
❑Accessory building 0 Multi-family Number of bedrooms:3
❑Master builder 0 Other: Number of bathrooms)3
JOB SITE INFORMATION AND LOCATION Total number of floors:2 201
Job site address:14558 SW 79TH AVE New dwelling area: 1 622 square feet ctsi
City/State/ZIP: Garage/carport area: 390 square feet t_e c—
Suite/bldg./apt.no.: Project name: Serenus Covered porch area square feet
Cross street/directions to job site: Deck area:0 square feet
Other structure area: 0 square feet Landing
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Serenus Lot no.:19 Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
NSI R Valuation: $
Existing building area: square feet
New building area: square feet
0 PROPERTY OWNER 0 TENANT Number of stories:2
Name:DR Horton Type of construction:
Address: 4380 SW Macadam Ave Ste 200 Occupancy groups:
City/State/ZIP: Portland OR 97239 Existing:
Phone:(503 ) 222-4151 Fax:( ) New:
pI¢ kilt 0 "` 4 I A , } *
¢t$!rt�:#* a+� t .: � t#i�l° 'u� t .. o"4.'"Y l'ia '' °#�$ + B ILDI.Nfr E'M FEES
"., . A akq _ '.a '� te4ul)
Business name: DR Horton
Structural plan review fee(or deposit):
Contact name: Emerald Weeks
FLS plan review fee(if applicable):
Address: 4380 SW Macadam Ave Ste 200
Total fees due upon application:
City/State/ZIP: Portland OR 97239
Phone:( 503 ) 222-4151 Fax::( ) Amount received:
E-mail: es weeks rt drhorton.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR
J roof-top mounted PhotoVoltaic Solar Panel System.
Business name: DR Horton Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 4380 SW Macadam Ave Ste 200 SolarInstallation Specialty Code checklist.
City/State/ZIP: Portland OR 97239 Permit Fee(includes plan review $180.00
y and administrative fees):
Phone:( 503 ) 222-4151 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB tic.:' 9 'Jb s � Q�i/'�(l/���L/L Total fee due upon application: $201.60
Authorized signature: �jyZ4i2,GLGGTi a26,2 a rZ This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name: Emerald Weeks Date: 6/3/2021 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPennitApp.doc 02/24/20I I 440-4613T(l l/02/COM/WEB)
Building Permit Application Checklist
- One- and Two-Family Dwelling FOR orrlcE USE ONE\
City of Tigard Date/BReceived
I Permit No.:
13125 SW Hall Blvd.,Tigard,OR 97223 y
g Associated permits:
I Phone: 503.718.2439 Fax: 503.598.1960
24-Hour Inspection Line: 503.639.4175 0 Electrical ❑ Plumbing 0 Mechanical
TiGAI:D Internet: www.tigard-or.gov ❑ Other:
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW 1 cs No N/A
I Land use actions completed. See jurisdiction criteria for concurrent reviews. x ' 0 0 U
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. x❑ 0 0
3 Verification of approved plat/lot. x 0 ❑ ❑
4 Fire district approval required. Name of district: • x 0 0 0
5 Septic system permit or authorization for remodel. Existing system capacity . x❑ 0 0
6 Sewer permit. NO 0 0
7 Water district approval. x 0 0 0
8 Soils report. Must carry original applicable stamp and signature on file or with application. x❑ ❑ ❑
9 Erosion control ❑plan ❑permit required. include drainage-way protection,silt fence design and location of catch- x❑ ❑ 0
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state x❑ 0 0
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if
copyright violations exist.
11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if x❑ 0 0
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements
and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction
indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size x❑ 0 0
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, x❑ ❑ ❑
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- x 0 0 0
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. x❑ ❑ 0
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendums showing foundation elevations with cross references are acceptable.
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- x❑ 0 0
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing x❑ 0 0
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered x❑ 0 0
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists x❑ 0 0
over 10 feet long and/or any beam/joist carrying a non-uniform load.
20 Manufactured floor/roof truss design details. x❑ ❑ 0
21 Energy Code compliance. identify the prescriptive path or provide calculations. A gas-piping schematic is required x 0 0 ❑
for four or more appliances.
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or x 0 ❑ ❑
architect licensed in Ore.on and shall be shown to be a s licable to the project under review.
JURISDICTIONAL SPECIFICS
23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2-x 11"or I I"x 17". 0 0 0
24 Two(2)sets each are required for Items 16, 19,20 and 22 above. 0 0 0
25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ❑ ❑ ❑
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. (] ❑ ❑
27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 0
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard 0 0 0
Street Tree List.
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 0 0
and protection measures must be drawn to scale and must include the project arborist's signature of approval.
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 0 0
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9, 1995.
I:\Building\Permits\BUP-RESPernitApp.doc 02/24/2011 440-461 3T(1 1/02/COM/W EB)
Mechanical Permit Applicatai CEIVED ,,(„t O,:,:1( : , si:(IN,,,
City of Tigard NOV 12021 R�Bed Permit No.:
• 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review
11 Phone: 503.718.2439 CITY OF TIGARU Date/By: Other Permit:
1 I t Ali O Inspection Line: 503.639.4175 II '' n Dete ReadylBy: Juris' El See Page 2 for
Internet: www.tigard-or.govV��Q�NG DIVISION Notified Method: I Supplemental Information
TYPE OF WORK COMMERCIAL FEE*SCHEDULE—USE CHECKLIST
® New construction 0 Addition/alteration/replacement Mechanical permit fees*are based on the value of the work
performed.Indicate the value(rounded to the nearest dollar)of all
❑ Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit.
CATEGORY OF CONSTRUCTION Value:$
RESIDENTIAL EQUIPMENT/SYSTEMS FEES*
❑ 1-and 2-family dwelling ❑Commercial/industrial 0 Accessory building
For special information use checklist.
❑ Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total
JOB SITE INFORMATION AND LOCATION Heating/cooling:
Job site address: 14558 SW 79TH AVE Air conditioning 46.75
Furnace 100,000 BTU(ducts/vents) 46.75
City/State/ZIP: Furnace 100,000+BTU(ducts/vents) I 54.91
Suite/bldg./apt.no.: Project name: Serenus Heat pump 61.06
Duct work I 23.32
Cross street/directions to job site:
Hydronic hot water system 23.32
Residential boiler(radiator or
hydronic) 23.32
Unit heaters(fuel-type,not electric),
in-wall,in-duct,suspended,etc. 46.75
Flue/vent for any of above 23.32
Subdivision: Serenus Lot no.: 19 Other: 23.32
Other fuel appliances:
Tax map/parcel no.:
Water heater 23.32
DESCRIPTION OF WORK Gas fireplace/insert 33.39
NSFR Flue vent for water heater or gas
fireplace 23.32
Log lighter(gas) 23.32
Wood/pellet stove 33.39
Wood fireplace/insert 23.32
Chimney/liner/flue/vent 23.32
0 PROPERTY OWNER 0 TENANT Other: 23.32
Environmental exhaust and ventilation:
Name: DR Horton Range hood/other kitchen
Address: 4380 SW Macadam Ave Ste 200 equipment 1 33.39
Clothes dryer exhaust 1 33.39
City/State/ZIP: Portland OR 97239 Single-duct exhaust(bathrooms, 4
toilet compartments,utility rooms) 23.32
Phone:( 503 ) 222-4151 Fax:( ) Attic/crawlspace fans 23.32
0 APPLICANT 0 CONTACT PERSON Other: 23.32
Business name: DR Horton
Fuel piping:
Emerald Weeks S14.15 for first four;54.03 for each additional
Contact name: 1
Furnace,etc.
Address: 4380 SW Macadam Ave Ste 200 Gas heat pump
City/State/ZIP: Portland OR 97239 Wall/suspended/unit heater
Water heater I
Phone:( 503 ) 222-4151 Fax: :( ) Fireplace
E-mail: esweeks@drhorton.com Range 1
Barbecue
CONTRACTOR Clothes dryer(gas)
Business name: Development Northwest Inc.,dba Wolcott HVAC Other:
MECHANICAL PERMIT FEES*
Address: 1075 W Historic Columbia River Hwy
Subtotal
City/State/ZIP: Troutdale,OR,97060 Minimum permit fee($90.00)
Phone:( 503 ) 667-1781 Fax:( 503 ) 667-9891 Plan review(25%of permit fee)
State surcharge(12%of permit fee)
CCB lie.: 112220 TOTAL PERMIT FEE
This permit application expires if a permit is not obtained within 180
1 / /� days after it has been accepted as complete.
Authorized signature: , 2/ �/ * Fee methodology set by Tri-County Building Industry Service Board
Print name: Andrew Darland Date: 10/21/21
I:\Bui Iding\Permits\MEC_PerrnitApp_052520.doe 440-4617T(II/02/COM/W EB)
Electrical Permit ApplicatioilEG
'EIVED FOR OFFICE USE ONLY
City of Tigard and Received
Date/By: Permit 4:
711 W i�
• 13125 S Hall Blvd.,Tigard,OR 97223 NOV 2071 Plan Review
Phone: 503.718.2439 Fax: 503.598.1960, Date/By Related Permit N:
Inspection Line: 503.639.4175 t,.l(Y OF T IGARL) Ready Date/By: Juris: El See Page 2 for
11('ARt) Internet: www.tigard-or.gov �! � r�` iYl�l�� Notified/Method: Supplemental Information
��
TYPE OF WORK 1 s! PLAN REVIEW
®New construction ❑ Addition/alteration/replacement Please check all that apply(submit 2 sets of plans wiitems checked):
❑Service or feeder 400 amps or more ❑Building over three stories.
0 Demolition ❑Other: where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10.000 amps at 150 volts or ❑Floating buildings.
❑ 1—and 2-family dwelling ElCommercial/industrial ❑Accessory building less to ground,or exceeds 14.000 ❑('ommercial-use agricultural
amps for all other installations. buildings.
❑ M ulti-family 0 Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived
0 Addition of new motor load of system.
Job#: Job site address: 14558 SW 79TH AVE I00HP or more. ❑"A","E "1-2","I-3
❑Six or more residential units. occupancy.
City/State/Zi P:
❑Health-care facilities. ❑Recreational vehicle parks.
Suite/bldg./apt.#: Project name: Serenus ❑Hazardous locations. 0 Supply voltage for more than
❑Se n ice or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
Description I Qty. I Each I TOtal
New residential single-or multi-family dwelling unit.
Subdivision: Serenus Lot#:19 Includes attached garage.
1,000 sq.ft.or less 1 168.54 4
Tax map/parcel#: Ea.add'I 500 sq ft.or portion 3 33.92 I
DESCRIPTION OF WORK Limited energy,residential 75.00 2
NSFR (with above sq.tt.)
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
Renewable Energy ❑ See Page 2
❑ PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation
Name: DR I lorton 200 amps or less 100.70 2
Address: 4380 SW Macadam Ave Ste 200 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 '_
City/State/ZIP: Portland OR 97239 601 amps to 1,000 amps 301.04 2
Phone:( 503 ) 222-4151 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: esweeks/iNrhorton.com drhorton.com relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 i
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date:
401 amps to 599 amps 168.54 2
Branch circuits—new,alteration,or extension,per panel
0 APPLICANT 0 CONTACT PERSON A.Fee for branch circuits with
Business name: DR Horton above service or feeder fee, 7.42 2
each branch circuit
Contact name:Emerald Weeks B.Fee for branch circuits without
4380 SW Macadam Ave Ste 200 service or feeder fee,first 56.18 2
Address: branch circuit
City/State/ZiP: Portland OR 97239 Each add'l branch circuit 7.42 2
222 4151Miscellaneous(service or feeder not included)
Phone:( 503 ) Fax: :( ) Each manufactured or modular
67.84 2
dwelling,service and/or feeder
Email: esweeksrtdrhorton,com
Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:Garner Electric Co Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy ❑ See Page 2 2
Address:2890 SE Brookwood Ave. panel,alteration,or extension.
City/State/ZIP:Hillsboro, OR 97123 Each additional inspection over allowable in any of the above
y Additional inspection(1 hr min) 66.25/hr
Phone:(503-648-4552 Fax:( ) Investigation(I hr min) 90.00/hr
Industrial plant(1 hr min) 78.18/hr
Email: ermits arnerelectric.com
p �g Inspections for which no 1cc is 90.00/hr
CCB Lie.: 121159 Electrical Lic.: 4-•05CII Suprv. Lie.:3707-S specifically listed(A hr min)
ELECTRICAL PERMIT FEES
Suprv. Electrician signature,required: ,.-..y r rr:r. Subtotal:
Print name: Charles Garner Date: ❑Plan Review Required(25%of pennit fee):
/' l State surcharge(12%of pennit fee):
Authorized signature:��!mot/2 /2- TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name: Emerald Weeks Date: 6/3/2021 days after it has been accepted as complete.
* Number of inspections allowed per permit.
I:,,Bnilding`..Pennits,ELC_PermitApp ELR_ERE.doc Rev 06i I72015 440-4615T(II'05'COM:WEB
•
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Description I Qly. I Each I Total I "
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
n Garage Door Opener* >100 kva(tee in accordance
with OAR 918-309-0040) 552.26 2
❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed('/hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Subtotal(Enter on Page I):
Fee for each commercial system: $75.00 * Number of inspections allowed per pennit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems: _
*No licenses are required. Licenses are required for all
other installations
I:.Building Pei mits.ELC_PermitApp_ELR ERE.doc Rev O6 17'2015
Plumbing Permit Application,.
Building Fixtures ECEI "`(E C FOR OFFICE USE ONLY
City of TigardNOV j. 702"1 Received Permit No.:
;� r 13125 SW Hall Blvd.,Tigard,OR 97223 � Date/By:
g Plan Review
■ Phone: 503.718.2439 Fax: 503.598.1• Date/By: Other Permit No.:
��f11 OF TIGAHL
T I G A It[) Inspection Line: 503.639.4175 r� c /� Date Ready/By: 1mis: 6J See Page 2 for
Internet: www.tigard-or.gov ;I JIi fl NG DhiiSiOt Notified/Method: Supplemental Information
TYPE OF WORK FEE* SCHEDULE
0 New construction ❑Demolition For special information use checklist.
Description Qty. Ea. I Total
❑Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection)
CATEGORY OF CONSTRUCTION SFR(1)bath 312.70
❑ 1-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 437.78
SFR(3)bath I 500.32
❑Accessory building 0 Multi-family
Each additional bath/kitchen 25.02
❑Master builder ❑Other: Fire sprinkler( sq.It.) Page 2
JOB SiTE INFORMATION AND LOCATION Site utilities:
Job site address:14558 SW 79TH AVE Catch basin or area drain 18.76
Drywell,leach line,or trench drain 18.76
City/State/ZIP:
Footing drain(no.linear ft.:_) Page 2
Suite/bldg./apt.no.: I Project name: Serenus Manufactured home utilities 50.03
Cross street/directions to job site: Manholes 18.76
Rain drain connector 18.76
Sanitary sewer(no.linear ft.:_) Page 2
Stonn sewer(no.linear ft.:_) Page 2
Water service(no.linear li.:_) Page 2
Subdivision: Serenus Lot no.:19 Fixture or item:
Tax map/parcel no.: Backtlow preventer 31.27
Backwater valve 12.51
DESCRIPTION OF WORK
Clothes washer 1 25.02
NSFR
Dishwasher 1 25.02
Drinking fountain 25.02
+'- Ejectors/sump 25.02
0 PROPERTY OWNER 0 TENANT Expansion tank 12.51
Fixture/sewer cap 25.02
Name: DR 1 lorton Floor drain/floor sink/hub 25.02
Address: 4380 SW Macadam Ave Ste 200
Garbage disposal 25.02
City/State/ZIP: Portland OR 97239 Hose bib 2 25.02
Phone:( 503 ) 222-4151 Fax:( ) Ice maker 12.51
0 APPLICANT ❑ CONTACT PERSON Interceptor/grease trap 25.02
Business name: DR Horton Medical gas(value:$ ) Page 2
Primer 12.51
Contact name: Emerald Weeks
Roof drain(commercial) 12.51
Address: 4380 SW Macadam Ave Ste 200
Sink/basin/lavatory 4 25.02
City/State/ZiP: Portland,OR 97239 Solar units(potable water) 62.54
Phone:( 503 ) 222-4151 Fax: :( ) Tub/shower/shower pan 2 12.51
Urinal 25.02
E-mail: esweeksndrhorton.com 3 25.02
Water closet
CONTRACTOR
Water heater 1 37.52
Business name: Alliance Plumbing,LLC Water piping/DWV 56.29
Address: 146 W 11istoric Columbia River Hwy Other: 25.02
City/State/ZiP: Troutdale,OR 97060 Subtotal
Minimum permit fee: $72.50
Phone:( 503)492-3490 Fax:( 503 ) 912-6438
Plan review (25%of pennit fee)
CCB Lie.: 184601 Plumbing Lic.no.: PB732
State surcharge(12%of pennit tee)
Authorized signature: / ��/--, TOTAL PERMIT FEE
This permit application expires if a permit is not obtained ssithin 180 days
Print name: Gavin Thomes Date: 7.01.2021
after it has been accepted as complete.
*Fee methodology set by iri-(busty Building Industry Service Board.
I:\Building'Permits.P1.MtJ-PennitApp.doc I0'01,09 440-46I6T(10/02/COM%WEB)
Plumbing Permit Application - City of Tigard
Page 2 - Supplemental Information
Fee Schedule: Residential Fire Suppression Systems:
Site Utilities Qty. Fee(ea) Total Square Footage: Permit Fee:
Footing drain- I, I00 50.03 0 to 2,000 $121.90
Footing drain-each additional 100' 37.52 2,001 to 3,600 $169.69
3,601 to 7,200 $233.20
Sewer-1st 100' 62.54 7,201 and greater $327.54
Sewer-each additional 100' 37.52
Water Service-1st 100' 62.54 Medical Gas Systems:
Water Service-each additional 100' 37.52 Valuation: Permit Fee:
Storm&Rain Drain-1st 100' 62.54 $I.00 to S5,000.00 Minimum fee S72.50
Storm&Rain Drain-each additional 100f 37.52 $5,001.00 to$10,000.00 $72.50 for the first$5,000.00 and$1.52 for
Other Ins ections or Fees Qty. Fee(ea) Total each additional$100.00 or fraction thereof,to
p and including$10,000.00.
Inspection of existing plumbing or for $10,001.00 to$25,000.00 $148.50 for the first$10,000.00 and$1.54 for
which no fee is specifically indicated 90.00/hr each additional$100.00 or fraction thereof,to
(minimum charge-1/2 hour) and including$25,000.00.
Inspections outside of normal business 90.00/hr $25,001.00 to$50,000.00 $379.50 for the first$25,000.00 and$1.45 for
hours(minimum charge-2 hours) each additional$100.00 or fraction thereof,to
Reinspection Fees 90.00/hr and including$50,000.00.
Additional plan review for revisions 90.00/hr $50,001.00 and up $742.00 for the first$50,000.00 and$1.20 for
(minimum charge-1/2 hour)
each additional$100.00 or fraction thereof.
Subtotal:
Commercial Fixture Work:
Are you capping,adding or replacing fixtures? If"yes",
please indicate work performed by fixture. Failure to
accurately report fixtures could result in increased sewer fees*. Plan Review for Plumbing Installations
Quantity by Fixture Type Plan review is required for any of the following.
Fixture Type for Replace/ Please check all that apply.
Work Performed: Capped Added Relocate
❑ Any new commercial building with water service 2"and
Baptistry/Font greater,except systems designed and stamped by licensed
Bath: -Tub/Shower engineer.
-Jacuzzi/Whirlpool
❑ New exterior plumbing site utilities for any complex structure
Car Wash: -Each Stall as defined in OAR918-780-0040.
-Drive Thru
Cuspidor/Water Aspirator 0 Medical gas and vacuum systems for health care facilities.
❑ Any multipurpose fire sprinkler system.
Dishwasher: -Commercial
Domestic El Any complex structure as defined in OAR918-780-0040.
Drinking Fountain
Eye Wash Submit 2 sets of plans with any of the above.
Floor Drain/sink: -2"
3„ Isometric or Riser Diagram
4" ❑ Isometric or riser diagram is required for new buildings
-Car Wash Drain that meet the qualifications above.
Garbage -Domestic non-food
Disposal: -Domestic food related
-Commercial food related
-Industrial food related
Ice Mach./Refrig.Drains Comments regarding fixture work:
Oil Separator(Gas Station)
Rec.Vehicle Dump Station
Shower: -Gang
-Stall
Sink: -Lav/Bar non-food related
-Bradley
-Com/Serv/Util food related
-Service *Note: If the fixture work under this permit results in an
Swimming Pool Filter increase of sewer EDUs,a sewer permit will be issued and
Washer-Clothes fees assessed for the sewer increase must be paid before the
Water Extractor
Water Closet-Toilet plumbing permit can be issued.
Urinal
Other Fixtures:
I:\Building\Permits\PLMF_PermitApp.doc 08/04/2011 2
City of Tigard
M COMMUNITY DEVELOPMENT DEPARTMENT
ill .
T 1 cAD Building Permit Review — Residential
Building Permit #: 32,02.l-O t-(0)(p
Site Address: I Ili 6 5 AO' IA" A-v-e
Project Name: ceArvWy Lot #:
Planning Review �I- - ,Q
Proposal: O 4J ek.G k d.cA/ CI,(i v .1
re Verify address/suite#active in Accela. ❑ In River Terrace: ,C� No ❑ Yes, River Terrace Review Addendum
Site Plan Elements: ZErosion Control OK
03 copies of site plan on 8-1/2"x 11"or 11 x 17"paper Retained trees with drip line and tree protection measures
Drawn to scale(standard architect or engineer scale) Footprint of new structure(including decks)and FFE
North arrow Utility locations&easements (required for new and additions)
gSite address,project or subdivision name and lot number iSidewalk/driveway approach
51 Applicant information(name and phone number) ELoca
ifOLot dimensions and building setback dimensions treet tree size,type and location
{�taQe of bu it i 0/Street names
• ®Corner elevations(2'contours if more than 4'differential)
j Lot area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? aYes ❑No
impervious area(applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown? ❑Yes Fi.No
?.Clean Water Services—Service Provider Letter(lot platted prior to 9/10/1995):
Required: ❑ Yes,applicant was notified ,R No Received: ❑ Yes ❑ No
Water Meter Fixture Unit Worksheet—Additions,Remodels and ADUs
Required: ❑ Yes,applicant was notified No Received: ❑ Yes E No
es D Nu---- Received: ❑ Yes ❑ No
Required: ❑ Yes,applicant was notified ❑ No Applied For: ❑ Yes ❑ No,stop intake
® Land Use Case#: d()3242O 0 0k 0 I RI Zoning: k-1 Z
13) Required Setbacks: Front: t 5 t Rear: y t Side: 5 Street Side: I 0` Garage: '7 01
t_P Building Height: Max. Height: 3 51 Actual Height: 2 - ,
Vi Landscape Area: 7.-0 % Z9 Lot Coverage Max: SO
Entrance Set back no more than 8'from street-facing wall xi Parallel to street or offset 45 degrees or less
Windows g2 Minimum 12°A of area of all street-facing facades
Garage E arage door is behind widest street-facing wall ❑ Yes No,one of the following is met:
❑ oo ds no more than 5'from wall and there is a co porch extending beyond garage.
❑ Door extends no an 5'from wall and ther a 12 sq ft.window above garage on 2nd floor.
❑ Garage door width is ❑ 12'or less ° or less of facade ❑ 60%or less and includes 7 of following:
❑ Covered porch ❑ Re entrance Wall offset ❑ 1'Roof eave ❑ Roof offset
❑ Fire shingles Lap Siding ❑ Roof pitch Gable,hip,or gambrel roof ❑ Dormer
❑ Acc siding ❑ Window trim ❑ Window recess ❑ Window projection ❑ Balcony
4 Visual Clearance ® Urban Forestry Plan
�C] Sensitive Lands: p Yes ❑ No Type: ( i4( 5 5`(�1� . H otip/hil " Valve
J) Conditions met prior to issuance of building permit r/
Notes: GGC (, i( (`P a.-
ja Approved By Planning: ��ti iLG� �i�- Date: 1(/#/7-8 2-I
Revisions (after Building Submittal only) Reviewer Date
Revision 1: ❑ Approved ❑ Not Approved
Revision 2: ❑ Approved ❑ Not Approved
C\Building\Forms\BldgPennitRvw_RES_122419.docx
Building Permit Submittal
Original Submittal Date: l! (2,1
Site Plans: # 3
Building Plans: # 3
Building Permit#: al Enter building permit# above.
Workflow Routing: Planning 1;i'Engineering 4A1. Permit Coordinator Building
Workflow Sign-off: a Sign-off for Planning(include notes from planning review)
Route Application Documents: V Engineering: (1) copy of permit application, (1) site plan, (1) building plan and
original plan review routing form.
CA Building: original permit application, site plans,building plans,engineer and
beam calculations and trust details,if applicable,etc.
Notes:
By Permit Technician: ej; 0 ?t.bce, QA,R. Date: 11(tt (p.
Engineering
..,nngin e ering Review
[ 51ope at building pad: z%
2/Conditions "Met"prior to issuance of building permit
D/Easements (encroachments) per engineering conditions of approval and plat
Er-Water Quality/Quantity Facility:
Assess Water Quality Fee in-lieu: ❑ Yes [,No
Assess Water Quantity Fee in-lieu: ❑ Yes LE' No
LIDA Facility on lot: ❑ Yes No
Final Plat Recorded:
❑ NOT Approved by Engineering: Date:
Notes:
ErApproved by Engineering: ,7-"yam,f /?y,Z(�.� . Date: I!/Zz-/ZO Z/
Revisions (after Building Submittal only) Reviewer Date
Revision 1: ❑ Approved ❑ Not Approved
Revision 2: ❑ Approved ❑ Not Approved
Permit Coordinator Review
Conditions "Met"prior to issuance of building permit
❑ Approved,NOT Released: Date:
Notes:
Revisions (after Building Submittal only)
Revision Notice 1: Date Sent to Applicant:
Revision Notice 2: Date Sent to Applicant:
SDC Exemption: ❑ Received 7'Does not apply
,11 SDC Fees Entered: Wash Co Trans Dev Tax: 7'Yes ❑ N/A
Tigard Trans SDC: 7 Yes ❑ N/A
Parks SDC: 7 Yes ❑ N/A
LIDA ❑ Yes f Z N/A
,I OK to Issue Permit
Approved by Permit Coordinator: 16r5r45&
Date: A1(23 120211