Permit UPI CITY OF TIGARD MECHANICAL PERMIT
COMMUNITY DEVELOPMENT Pe
COMMUNITY MEC2021-00949
Date Issued: 12/20/2021
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S101 BB01300
Jurisdiction: Tigard
Site address: 11956 SW GARDEN PL
Project: Zoom+Care Lab&Pharmacy Subdivision: CROW PARK 217 Lot: 1
Project Description: TI-(6)new RTU's and associated ducting servicing all spaces. New exhaust fans to prepack room 126&129.
Ductless hood for filtration at prepack room. Duct mount humidifiers at pharmacy&prepack room.New ducting
for RTU at warehouse.
Contractor: NORWEST CONTRACTORS INC Owner: BKM PARK BC 252 LLC
PO BOX 25305 BY SLK GLOBAL SOLUTIONS AMERICA
PORTLAND, OR 97298-0305 2727 LBJ FREEWAY STE 806
DALLAS, TX 75234
PHONE: 503-291-6986 PHONE:
FAX: 503-291-7036
FEES
Specifics: Description Date Amount
Type of Use: COM Permit Fee 12/15/2021 $1,388.61
Class of Work: ALT Type of Const: VB Plan Review 12/15/2021 $347.15
Occupancy Grp: B Occupancy Load: 12%State Surcharge-Mechanical 12/15/2021 $166.63
Stories: 1 Info Process/Archiving-Lg$2.00(over 12/15/2021 $4.00
11x17)
Project Valuation: $51,000.00
Fuel Air Handlers
Fuel Types: Natural Gas Units< 10000 cfm:
Gas Pressure: Units> 10000 cfm:
Furnaces Boilers&Compressors
Furnaces< 100K BTU: 0-3 HP:
Furnaces>= 100K BTU: 3-15 HP:
Floor Furnaces: 15-30 HP:
Unit Heaters: 30-50 HP:
Vents w/o Appliances: 50 or Greater HP:
Air Conditioning:
Heat Pump:
Appliances
Vent Fans: 1 Vent Systems: Total $1,906.39
Hoods: Comm Incinerators:
Required Items and Reports(Conditions)
Woodstoves: Gas Fireplaces:
Clothes Dryers: Other Mech Units:
Gas Outlets: Other Desc:
Duct Work: 100
Fire/Smoke Dampers:
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other
applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of
issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon
Utility Notification Center. Those rules ar set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules
Issued By: Permittee Signature: - -.. ���25
Call 503.639.4175 by 7:00 a.m.for the next available inspection date. f
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
r.
Mechanical Permit Application (� FOR OFFICE USE ONLY
City of Tigard RECEIVE IReceived l�2q ZO2/ / :f 4E ZO21-�09
Date/IIy: Permit No.:
Mil
" 13125 SW Hall Blvd.,Tigard,OR 97223
Phone: 503.718.2439 Fax: 503.591,1960 Plan Revie
NOV 15 2021 6 Other Permit:
Date/By:
TIGARD Inspection Line: 503.639.4175 Date Ready/By: Juris: 0 See Page 2 for
Internet: www.tigard-or.gov CITY OF TIGARD Noti d/Method: / / 411� Supplemental Information
B
TYPE OF WORK CO 1E . 'FEE*SCHEDULE — USE CHECKLIST
Mechanical permit lees*are based on the value of the work
❑New construction it Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all
❑Demolition ❑ Other: _mechanical materials,equipment.labor,overhead,and profit.
-- Value:$ $51,000
CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES*
❑ 1-and 2-family dwelling x Commercial/industrial ❑Accessory building For special information use checklist.
❑ Multi-family ❑ Master builder ❑Other: Description Qty. Ea. Total
JOB SITE INFORMATION AND LOCATION Heating/cooling:
Air conditioning 46.75
Job site address: 11956 SW Garden Place Furnace 100,000 BTU(duets/vents) 46.75
City/State/ZIP: Tigard, OR 97223 Furnace 100,000+BTU(ducts/vents) 54.91
- cleat pump 61.06
Suite/bldg/apt.no.: Project name:Zoom+Care Lab&Pharmacy Duct work 23.32
Cross street/directions to job site: Hydronic hot water system 23.32
Off SW Hall Blvd at HWY 217&HWY 99W, SW Garden Place Residential boiler(radiator or
hydronic) 23.32
Unit heaters(fuel-type,not electric),
in-wall,in-duct,suspended,etc. 46.75
Flue/vent for any of above 23.32
Subdivision: Lot no.: Other: 23.32
Other fuel appliances:
Tax map/parcel no.: 2S101 BB01300 Water heater 23.32
DESCRIPTION OF WORK Gas fireplace/insert 33.39
Flue vent for water heater or gas
Office T.I.within an existing office park building. Six new RTUs and associated fireplace _ 23.32 _
ducting serving all spaces. New exhaust fans at Prepack rooms 126& 129. Log lighter(gas) 23.32
Wood/pellet stove 33.39
Ductless hoods for filtration at prepack rooms. Duct mount humidifiers at Wood fireplace/inner 23.32
Pharmacy and Prepack rooms. New ducting from existing RTU at warehouse. Chimney/liner/flue/vent 23.32
Other: 23.32
❑ PROPERTY OWNER x[ TENANT
Environmental exhaust and ventilation:
Name: Zoom+Care Contact: Jeffrey Schoenberg Range hood/other kitchen
equipment 33.39
Address: 1455 NW 'rivingSt#600 -� --
Clothes dryer exhaust 33.39
City/Slate/ZIP: Portland, OR 97209 Single-duct exhaust(bathrooms,
toilet compartments,utility rooms) 23.32
Phone:( 206)852-8751 Fax:( ) Attic/crawlspace fans 23.32
X APPLICANT X CONTACT PERSON Other: 23.32
Business name: Scott I Edwards Architecture LLC Fuel piping:
$14.15 for first four;$4.03 for each additional
Contact name: Mark Steinhardt Furnace,etc.
Address: 2525 E Burnside St Gas heat pump
-. Wall/suspended/unit heater
City/State/71P: Portland, OR 97214 Water heater
Phone:( 503)896-5385 Fax: ( ) Fireplace
Range
E-mail: msteinhardt@seallp.com Barbecue
CONTRACTOR Clothes dryer(gas)
Business name: NW Contractors, Inc Attn: Seth Kiser Other: MECHANICAL PERMIT FEES*
Address: 7235 SW Stephen Ln. subtotal-
City/State/ZIP: Portland, OR 97225 Minimum permit fee($90.00)Plan review(25%of permit fee)
Phone:( 503) 291-6986 Fax:( ) State surcharge(12%of permit fee)
CCIR lie.: OR 89425 TOTAL PERMIT FEE I
This permit application expires if a permit is not obtained within 181)
tt/�{ Irr days after it has been accepted as complete.
Authorized signature: IY 1 •-'� * Fee methodology set by Tri-County Building Industry Service Board
Print name: Mark Steinhardt Date:11/11/21
I:'nulldin Icrm,is..mi S_icrmicApp_o4U I 1}.doe 440-4617T(1 Iro2'cOM/WGt)
City of Tigard
111 COMMUNITY DEVELOPMENT DEPARTMENT
TIGARD Building Permit Review — Commercial - No Land Use
Building Permit #: , Z /•-09
Site Address: 0,466 4,{ofitr\ p6 Suite/Bldg#:
Project Name: 7lA V`e 1,61b V ci VV,a CA
(Name of commercial business occupying the space. If vacant,enter Spec Space'
Planning Review
Proposal: c T F(i v_ VLe,v.1 (Ltf/t1 (/f!1 V\t„14) PAX t,6(,(./SC {- 4L1/L5--
Existing Business Activity: ]04 4- C
Proposed Business Activity:
liPj Verify site address/suite#exists and active in permit system.
❑ River Terrace Neighborhood: ❑ Yes 1 No
pZoning: G V
X)Permitted Use: )0 Yes ❑ No ❑ Spec Space
Confirm no land use required.
r-1 Business License:
Exists: /�Yes ❑ No,applicant was provided a business license application
Notes:
Approved by Planning: Aits 1/ 0(A/l Date: I,l q -2, Z(
Revisions (after Building Submittal only) Reviewer Date
Revision 1: ❑ Approved ❑ Not Approved
Revision 2: ❑ Approved ❑ Not Approved
Revision 3: ❑ Approved ❑ Not Approved
Building Permit Submittal
Original Submittal Date: // /S/2°21
Site Plans: # 2
Building Plans: # ,Z
Building Permit#: 'LJ Enter building permit# above.
Workflow Routing: r Planning ❑ Permit Coordinator CVBuilding
Workflow Sign-off: Sign-off for Planning(include notes from planning review)
Route Application Documents: 4 Building: original permit application,site plans,building plans,engineer and
beam calculations and trust details,if applicable,etc.
Notes: /,
By Permit Technician: Date: /1/29,u112/
I:\Building\Forms\BldgPermitRvw_COM NoLandUse_111819.docx
Permit Coordinator Review
❑ Conditions "Met"prior to issuance of building permit
❑ Approved,NOT Released: Date:
Notes:
Revisions(after Building Submittal only)
Revision Notice 1: Date Sent to Applicant:
Revision Notice 2: Date Sent to Applicant
Revision Notice 3: Date Sent to Applicant
❑ SDC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes ❑ N/A
Tigard Trans SDC: ❑ Yes ❑ N/A
Parks SDC: ❑ Yes ❑ N/A
❑ OK to Issue Permit
Approved by Permit Coordinator: Date:
I:\Building\Forms\BldgPermitRvw COM NoLandUse_111819.docx