Specifications aui°2ao-a>297 73or ,0,9 rAtcyrm RECEIVED NOV 18 2021 CITY OF TIGARD Y. .J INC . SIGN ENGINEERIBUILDINGDIVISION November 8,2021 Structural Calculations Prepared For: Acorn Sign 4100 West Clay Street Richmond,VA Project: JTS_214021 LL Flooring#1331 —Wall Sign 7301 SW Dartmouth Tigard, OR Prepared By: YJ Inc. P.O. Box 802050 Santa Clarita, CA 91380 PRO `�c �c�s% ORE' • ` 0O\ 1 sac J� N o A !!AAC� (by" �ti EXPIRES: 06/30/2023 '\ Total 9 - pages including cover I Sign Design Based On 2019 OSSC - II - 18-6 34" Job. JTS 214021 3' I I EQ. TYP. Project LL Flowing s1331-NNII Sign TYP.' 1'~—TYP. ^ Job Locamn 7301 SWdeDaHrnouth —— -I O • • ' • • e—3/8"DIA..2 VT NOM.EMBED. 1NPVi DATA HILTI KB-TZ 2 S.S.EXP. Exposure ce• aANCHOR,ICC-ESRN4266. goryl6.0 or DI = C TYP. Risk Category It � D UPomeb Design WIn93Maa 4,. 6 54 MPH ljr FT µopogtpm:lector KFlat „ 1 FT gh of thesgn 2642 FT Merkel dim enslon ifs wall,s=hl 1056 FT Dimension dimension m B = t856 FT '('‘ ‘_‘.2, Z:1> Dimension of'Mum corer L 058 FT ANALYSIS WbeRYpnssve • ' 7'.. • ya0 Ice,sure el - 22.62 PSF When Q:=velocity prassun sl height h.1 Eg.26.10-1 pegs 266! a K-=nbcet heigM060ure spos ncleek17( = 0.93 •vketed al ress BOOM gR ire levelco•S.i ITaO.M 10-1.pap*2691 Ke=wind dnc1ma0fy boor(Tee.2661,pope 266) • 0.65 ta631! 1000' K,=groun0•N1•tlon factor a«(Ttl z6.9-t.pegs 266) 1.00 TYP. SIGN CABINET fit^-^^ Wind W5RLRW Rise e n (Sec.304 2 62941 Mak horizontal Wnd pressurea ps•GC =e= ri6.11 IPSF GC,.ex0maI measure coefficients IFIg.30.5-1.pegs 3631 0.98 L L. J L L O 0 =Bs.to gross ens a 174.2 FT. •..: DESIGN SUMMARY AllowenI 0 0 0 I Des4gn Wind Stress Derlgn Wind Factor= OA TR De•9n WIrM Pressure= 0.8 N p a 18.00 PSF Design W InObrce.F= 16.00 x As= 260 KIPS rr 1 r ` Sign Parameters. Weigh of<aonet OL= 701 LBS Vertical distance Oetween anchors.)= 10.00 FT n(rum)= 068 FT Max offset torn conneclron= 0.00 FT Mm no of top or Solt.anchors= 8 NO. — —e • • • • • • 0 Anchor Design ISee attached HILT/Prof's cakj 1. Loads per AO 31844 ELEVATION Unbotoed Load Unit Fectar Factored Load Daedoad Sher 50 LBS 1.2 60 N.T.S. Windloed.Temlm 203 LBS 1.8 325 Hell 10B-7Z2 S.S.EWANSION ANCHOR USE ICC-ESRA4288 NOTE:SPECIAL INSPECTION REQUIRED FOR POST INSTALLED ANCHOR PER ICC-ESR114286. I are-DIA.a 212E NOM EN VIED I —EX.SOLID FILLED NOTES: L.-7y CMU WALL /-- D PRO 8 GENERAL: STEEL: WELDING ti F SIGN DESIGN IS BASED ON ADEQUATE EXISTING SUPPORT ELEMENTS. DESIGN AND FABRICATION ACCORDING TO 2019 OSSC STEEL r( Age / •PROVIDE ISOLATION OF DISSIMILAR MATERIALS. PLATE,ANGLE.CHANNEL TEE'ASTM A36 DESIGN AND FABRICATION ACCORDING TO AWE D1.1./D1.3 eJ - •AWS CERTIFICATION REQUIRED FOR ALL STRUCTURAL WELDERS. ' / O\ / • COAT ALUMINUM IN CONTACT WITH CONCRETE WATH ZINC RICH PAINT. .WADE FLANGE.ASTM A992 ✓ •THERE IS NO PROTECTION ZONE AS DEFINED IN AISC 341-16. •ROUND PIPE:ASTM A53 GRADE B OR EQUIVALENT. •E70 XX ELECTRODE FOR SMAW PROCESS. i�s ¢ •E7OS XX ELECTRODE FOR GMAW PROCESS. 1'.'1 1-. a l PROVIDE FULLY WELDED END CAPS AT EXPOSED OPEN ENDS OF ASS ROUND,SQUARE,AND RECTANGULAR TUBE.ASTM A500 GRADE 8 3I6'DIA.,212'NOM.EMBED. ER7 XX ELECTRODE FOR GTAW PROCESS. `� - / STEEL I ALUM.TUBES,MATCH THICKNESS LIKE FOR LIKE. OR EQUIVALENT. HILT KB• -TZ 2 S.S.EXP. E]OT XX ELECTRODE FOR FCAW PROCESS. e"i •W 1 `° % ANCHOR,ICC-ESR64266, SLOPE TOP OF EXPOSED FOOTING AWAY FROM DIRECT BURIAL POSTS -ALL ANCHORS BOLTS SHOULD BE:ASTM F1554 ALL WELDS SHALL BE MADE WITH A FILLER METAL THAT CAN PRODUCE . TYP. ALL EXPOSED STEEL TO BE PRIMED 8 PAINTED(POWDER COAT AS AN -ALL STEEL MACHINED BOLTS SHOULD BE.ASTM A307 OR ASTM A449 WELDS THAT HAVE A MINIMUM GHARPY V-NOTCH TOUGHNESS OF 20FT-LB OPTION)OR ALTERNATIVELY USE GALVANIZED STEEL. •ALL STAINLESS STEEL MACHINED BOLTS SHOULD BE:ASTM A276 AT ZERO O.AS DETERMINED BY THE APPROPRIATE AWS AS CLASSIFICATION ALL BOLTS TO BE ZINC COATED:ASTM B633 TEST METHOD OR MFGS.CERTIFICATION. , /C P5 \lo ANCHORS: 'DEFORMED REINFORCING REBAR:ASTM A615 GRADE 60. ALUMINUM -___ /� \\Q� O SECTION BRAND NAME APPROVED POST INSTALLED ANCHORS SPECIFIED ON ALUMINUM: DESIGN AND FABRICATION ACCORDING TO AWS D1.2.ALL WELDING IN EXPIRES: 06/30/2023 ^ N.T.S. PLANS MAY BE SUBSTITUTED BY APPROVED EQUAL. DESIGN ANGLES, HANON A TEE,ING SQUNG TO ARE ALU.D SIGNIMANGN UAL ACCORDANCE WITH THE LATEST EDITION OF THE AWS A 5.1D. FILLER ALLOYS PER TABLES M.9.1 e M.9.2 OF 2015 ALUMINUM DESIGN MANUAL •ALLOY 6061-T6 WITH 0 098 LBS PER CUBIC INCH. www.yjinc can SIEETTRLE'. DRN BY: SR. DATE LEST REVISED: Nov 04,2021 REV.NO.REV.DATE REVISED BY PROJECT JOBN.JTS 214021 LL Flooring N1331 W'aII 51gn_7301 SW DanmoNh Tigard OR I • P.O.BOX 802050 I rB a F'a�1r�X F g> �,#'�3 1 CH(BY. T.J. PROJ.START DATE: 072621 1 -I-I- - PROJECT LOCATION: LL FLOORING 81331 SHEETS • SANTA CLARITA CA 91380 REV BY: T.J. SCALE. AS SHCVIN 2 -J-I- 730)SW DARTMOUTH WALL L s,F FtA' - TIGRRD,OR 1 OF 1 TEL.(661)259-0700 FAX.(641)259-0900 PLOTTED BY. Loch User ON i1M2021 9:5300 AN 3 -l-/- - Mllii .Tl Hilti PROFIS Engineering 3.0.73 www.hilti.com Company: YJ inc. Page: 1 Address: 33336 Agua Dulce Canyon Rd.Suite 101 Specifier: V.J Phone I Fax: 661-259-0700 I E-Mail: info@yjinc.com Design: JTS_214021_LL Flooring#1331 Date: 11/4/2021 • Fastening point: 7301 SW Dartmouth,Tigard,OR Specifiers comments:Wall Sign 1 Input data Anchor type and diameter: Kwlk Bolt TZ2-SS 304 3/8(2 1/2) *...#1100001. Item number: 2210243 KB-TZ2 3/8x3 1/2 SS304 Effective embedment depth: het=2.500 in. Material: AISI 304 Evaluation Service Report: ESR-4561 Issued I Valid: 3/1/2021 112/1/2021 Proof: Design Method ASD Masonry Stand-off installation: eb=0.000 in.(no stand-off);t=0.500 in. Anchor platen: l x ly x t=2.500 in.x 2.500 in.x 0.500 in.;(Recommended plate thickness:not calculated) Profile: no profile Base material: Grout-filled CMU,L x W x H:16.000 in.x 8.000 in.x 8.000 in.; Joints:vertical:0.375 in.;horizontal:0.375 in. Base material temperature:68°F Installation: Face installation Seismic loads no R- The anchor calculation is based on a rigid anchor plate assumption. Geometry[in.] Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2021 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 1 MI111..TI • Hilti PROFIS Engineering 3.0.73 www.hilti.com • Company: YJ inc. Page: 2 Address: 33336 Agua Dulce Canyon Rd.Suite 101 Specifier: V.J Phone I Fax: 661-259-0700 I E-Mail: info@yjinc.com Design: JTS_214021_LL Flooring#1331 Date: 11/4/2021 Fastening point: 7301 SW Dartmouth,Tigard,OR Geometry[in.]&Loading[Ib,in.lb] I i ' I'1 it, s)roa 1.1 Design results Case Description Forces[Ib]/Moments[in.lb] Seismic Max.Util.Anchor[%] 1 Combination 1 N=203;Vx=0;Vy=-50; no 35 Mx=0;My=0;MZ=0; 2 Load case/Resulting anchor forces •y Load case:Service loads Anchor reactions[Ib] Tension force:(+Tension,-Compression) Anchor Tension force Shear force Shear force x Shear force y 1 203 50 0 -50 çi max.compressive strain: -[Too] max.compressive stress: -[psi] resulting tension force in(x/y)=(0.000/0.000): 203[Ib] resulting compression force in(x/y)=(0.000/0.000):0[Ib] Anchor forces are calculated based on the assumption of a rigid anchor plate. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2021 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 2 I011IIATI Hilti PROFIS Engineering 3.0.73 www.hilti.com Company: YJ inc. Page: 3 Address: 33336 Agua Dulce Canyon Rd.Suite 101 Specifier: V.J Phone I Fax: 661-259-0700 I E-Mail: info@yjinc.com Design: JTS_214021_LL Flooring#1331 Date: 11/4/2021 • Fastening point: 7301 SW Dartmouth,Tigard,OR 3 Tension load (Most utilized anchor 1) Load Pe[lb] Capacity Pt[lb] Utilization Sp=Pe/Pt[%] Status Overall strength 203 590 35 OK 3.1 Overall strength Pt,ease =ESR Value refer to ICC-ES ESR-4561 Pt =Pt,ease'fred,E'fred,s fred,Temp'fred,Bedjoint Pt >Ps Variables Cmin[in.] Ccr[in.] sm;n[in.] Ser[in.] Temperature[°F] 4.000 12.000 3.000 10.000 68 Results 1 Pt[lb] Pt,Base[Ib] Ps[lb] fred,E fred,S fred,Temp fred,Bedjoint 590 590 203 1.000 1.000 1.000 1.000 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2021 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 3 PI ILITI Hilti PROFIS Engineering 3.0.73 www.hilti.com Company: YJ inc. Page: 4 Address: 33336 Agua Dulce Canyon Rd.Suite 101 Specifier: V.J Phone I Fax: 661-259-0700 I E-Mail: info@yjinc.com Design: JTS_214021_LL Flooring#1331 Date: 11/4/2021 Fastening point: 7301 SW Dartmouth,Tigard,OR 4 Shear load (Most utilized anchor 1) Load VS[Ib] Capacity Vt[lb] Utilization 13v=V5Nt[Vol Status Overall strength para and perp,(Dir.x-)1 - - 8 OK 'Shear utilization may result from parallel and perpendicular shear(see details) 4.1 Overall strength parallel Vt Base.11 =ESR Value refer to ICC-ES ESR-4561 Vl,ll =Vt,Base,ll fred,E.;l fred,s,ll fred,Temp Vt,11 >Vs.l'. Variables Cmin[in.] cm[in.] Smin[in.] scr[in.] Temperature[°F] 4.000 12.000 3.000 10.000 68 Results Vt.0[Ib] V1,Base,l1[Ib] Vs di[Ib] fred,E,ll fred,S,p fred Temp Utilization(3, [%] 695 695 -50 1.000 1.000 1.000 7 4.2 Overall strength perpendicular Vt,Base,1 =ESR Value refer to ICC-ES ESR-4561 Vt,1 =V1,Base,1'fred,E,1 freds,l fred,Temp Vs,1 Variables Cmin[in.] cef[in.] smin[in.] scr[in.] Temperature 1°F] 4.000 12.000 3.000 10.000 68 Results V [lb] V1,8ase,l [Ib] VS,I [Ib] fred,E,l fred,S,t fred,Temp Utilization Rv,l[%] t,L 0 695 0 0.000 0.000 1.000 0 4.3 Shear interaction 13v.11 Vt IIII Pv,` Vt,l S Utilization I3v[%] Status 0.072 0.000 1.667 8 OK av,l`=1.0 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2021 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schwan 4 i■I■IIII�TI Hilti PROFIS Engineering 3.0.73 www.hilti.com Company: YJ inc. Page: 5 Address: 33336 Agua Dulce Canyon Rd.Suite 101 Specifier: V.J Phone I Fax: 661-259-0700 I E-Mail: info@yjinc.com Design: JTS_214021_LL Flooring#1331 Date: 11/4/2021 Fastening point: 7301 SW Dartmouth,Tigard,OR 5 Combined tension and shear loads (Most utilized anchor 1) P VL V RP=?, avii-Vs 11 Rv,1=V�1 a Utilization RP,v[%] Status r. 0.344 0.072 0.000 1.667 19 OK RP,v=RP+rv,II+F'V,1<=1.o 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations(AS 5216:2021,ETAG 001/Annex C, EOTA TR029 etc.).This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered-the anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the design loading.PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions,please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • The min.sizes of the bricks,the masonry compressive strength,the type/strength of the mortar and the grout(in case of fully grouted CMU walls)has to fulfill the requirements given in the relevant ESR-approval or in the PTG. • Only the local load transfer from the anchor(s)to the wall is considered,a further load transfer in the wall is not covered by PROFIS! • Wall is assumed as being perfectly aligned vertically—checking required(!): Noncompliance can lead to significantly different distribution of forces and higher tension loads than those calculated by PROFIS.Masonry wall must not have any damages(neither visible nor not visible)! While installation,the positioning of the anchors needs to be maintained as in the design phase i.e.either relative to the brick or relative to the mortar joints. • The effect of the joints on the compressive stress distribution on the plate/bricks was not taken into consideration. • If no significant resistance is felt over the entire depth of the hole when drilling(e.g.in unfilled butt joints),the anchor should not be set at this position or the area should be assessed and reinforced.Hilti recommends the anchoring in masonry always with sieve sleeve.Anchors can only be installed without sieve sleeves in solid bricks when it is guaranteed that it has not any hole or void. • The accessories and installation remarks listed on this report are for the information of the user only.In any case,the instructions for use provided with the product have to be followed to ensure a proper installation. • The compliance with current standards(e.g.2015,2012,2009 and 2006 IBC)is the responsibility of the user. • Drilling method(hammer,rotary)to be in accordance with the approval! • Masonry needs to be built in a regular way in accordance with state-of the art guidelines! • Warnings/Notes-OST in Masonry HNA! Fastening meets the design criteria! Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2021 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 5 1■11111.I.T1 Hilti PROFIS Engineering 3.0.73 www.hilti.com Company: YJ inc. Page: 6 Address: 33336 Agua Dulce Canyon Rd.Suite 101 Specifier: V.J Phone I Fax: 661-259-0700 I E-Mail: info@yjinc.com Design: JTS_214021_LL Flooring#1331 Date: 11/4/2021 Fastening point: 7301 SW Dartmouth,Tigard,OR 7 Installation data Anchor type and diameter:Kwik Bolt TZ2-SS 304 3/8(2 1/2) Profile:no profile Item number:2210243 KB-TZ2 3/8x3 1/2 SS304 Hole diameter in the fixture:di=0.438 in. Maximum installation torque:181 in.lb Plate thickness(input):0.500 in. Hole diameter in the base material:0.375 in. Hole depth in the base material:3.250 in. Drilling method:Drilled in hammer mode Minimum thickness of the base material:7.625 in. Hilti KB-TZ2 stud anchor with 2.5 in embedment,3/8(2 1/2),Stainless steel,installation per ESR-4561 • Y 1.250 1.250 • • o o in in N N \ / o o uO u, N N • • 1.250 1.250 • • • Coordinates Anchor[in.] Anchor x y c.x c,x C1 c,y 1 0.000 0.000 15.000 15.000 15.000 15.000 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2021 Hilti AG,FL-9494 Schaan Hitti is a registered Trademark of Hilti AG,Schaan 6 I10111.T1 Hilti PROFIS Engineering 3.0.73 www.hilti.com • Company: YJ inc. Page: 7 Address: 33336 Agua Dulce Canyon Rd.Suite 101 Specifier: V.J Phone I Fax: 661-259-0700 I E-Mail: info@yjinc.com Design: JTS_214021_LL Flooring#1331 Date: 11/4/2021 Fastening point: 7301 SW Dartmouth,Tigard,OR 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you. Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering(c)2003-2021 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan • 7