Loading...
Permit IN ,� CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00514 Date Issued: 12/14/2021 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 E Parcel: 1 S 136AA02201 Jurisdiction: Tigard Site address: 6501 SW OAK ST Subdivision: None Lot: None 11, Project: Peterson 1 Project Description: Rooftop Solar PV 5.18 kW for the garage. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $7,511.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 2 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof Top Solar PV System 5.96 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: PETERSON,THOMAS C ION DEVELOPER LLC Required Items and Reports(Conditions) PO BOX 80954 3214 NORTH UNIVERSITY AVE PORTLAND,OR 97280 503 PROVO,UT 84604 PHONE: PHONE: (888)781-7074 FAX: Total Fees: $442.92 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law rqiquires you to flow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Q59-nM-M1n rhrni inh t1 Qc9-n _noon i mov n a i i of thn rnlnc nr dirt ni inctinnc to(li IN!`by roiiinn 5n'2 9'29 1QR7 nr 1 RCM 4'29 9144 Issued By: it//. / Permittee Signature: Gw/J kd//�r, Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. Building Permit Applicatio F —1II2 ,j . E"EI V ED ��Aro"Residential hoR ou 1.:( is t Si. O\l.' City of Tigard NOV 2 3 2021 Received 1 '-�i DateBy: ��7/ POP PennitNo.: ST202/-0cj5! 13125 SW Hall Blvd.,Tigard,OR 97223 ITY Plan Review' II Phone: 503.718.2439 Fax: 503.598.19vv OFTIGARI� Date/By: 21 A.�' Other Permit: I I G A K u Inspection Line: 503.639.4175 3UILDING DIVISION Date Ready/By: �. luris: ® See Page 2 for Internet: www.tigard-or.gov rlPotified/Method: �1 Z21 Ile,— Supplemental Information TYPE OF WORK [s► REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑ Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ®Other: PV Solar equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® 1-and 2-family dwelling ❑Commercial/industrial Valuation: $ 7511 0 Accessory building 0 Multi-family Number of bedrooms: 1 ❑Master builder 0 Other: Number of bathrooms: 1.1' JOB SITE INFORMATION AND LOCATION Total number of floors: ! Job site address: 6501 SW Oak St New dwelling area: square feet City/State/ZIP: Tigard,Oregon,97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Thomas Peterson(Garages)Solar Install Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Portland West,Raleigh Hills I Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of solar panels on existing residential roof. 5.18 kW Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER 0 TENANT Number of stories: Name: Thomas Peterson Type of construction: Address: 6501 SW Oak St Occupancy groups: City/State/ZIP: Tigard,Oregon,97223 Existing: Phone:( 503 )318-6349 Fax:( ) New: IR APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule Business name: ION DEVELOPER LLC Structural plan review fee(or deposit): Contact name:Anastasia Heule FLS plan review fee(if applicable): Address:4801 N University Ave#900 Total fees due upon application: City/State/ZIP: Provo, UT 84604 Phone:( 801) 326-0959 x8760 Fax::(801 ) 607-6826 Amount received: E-mail: permits@ionsolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name: ION DEVELOPER LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 4801 N University Ave#900 Solar Installation Specialty Code checklist. City/State/ZIP: Provo, UT 84604 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 888) 781-7074 Fax:(801 )607-6826 State surcharge(12%of permit fee): $21.60 CCB lie.: 230394 Total fee due upon application: $201.60 Authorized signature: A rta4twsizu Reale This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Anastasia Heule Date: 11/4/2021 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPennitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) A 'iectrical Permit Application FOR OFFICE USE ONLY City of Tigard RECEIVED Received ri -� Date/B : ST v 61 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 Plan Review Related Pennit#: NOV 2 3 2021 Date/ Inspection Line: 503.639.4175 Ready Ready Date/By: Jtuis: VI See Page 2 for 1.1 G A R D Internet: www.tigard-or.gov Notified/Method: Supplemental Information CITY OF TIGARD TYPE OF WM IN (�,/cIO� PLAN REVIEW 0 New construction ❑Addition/alteraattionl ep'iaceifiL�i�J Please check all that apply(submit 2 sets of plans w/items checked): 0 Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition ®other: PV Solar where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. 1-and 2-familydwellingCommercial/industrial less to ground,or exceeds 14,000 0 Commercial-use agricultural ® ❑ ❑Accessory building Multi-familyMaster builder Other: amps for all other installations. buildings. ❑ ❑ ❑ ❑Fire pump. ❑Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address: 6501 SW Oak St I00HP or more. ❑"A","E","1-2","1-3", ❑Six or more residential units. occupancy. City/State/ZIP: Tigard,Oregon,97223 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: Thomas Peterson(Garages)Solar Install 0 Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Portland West,Raleigh Hills Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential Installation of solar panels on existing residential roof. 5.18 kW (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 Addition of(2) 0-30A circuit(s) residential(with above sq.ft.) Renewable Energy ❑ See Page 2 ® PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation Name: Thomas Peterson 200 amps or less 100.70 2 Address: 6501 SW Oak St 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Tigard,Oregon,97223 601 amps to 1,000 amps 301.04 2 Phone:( 503 )318-6349 Fax:( ) Over 1,000 amps or volts 552.26 2 • Temporary services or feeders installation,alteration,and/or Email: tj@portlandwoodworking.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 rill APPLICANT 0 CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: ION DEVELOPER LLC above service or feeder fee, 7.42 2 each branch circuit Contact name:Anastasia Heule B.Fee for branch circuits without ' service Address: 4801 N University Ave#900 branch cicirca der fee,first 1 56.18 56.18 2 t City/State/ZIP: Provo, UT 84604 Each add'l branch circuit 1 7.42 7.42 2 Miscellaneous(service or feeder not included) Phone:( 801 ) 326-0959 x8760 Fax: :(801 )607-6826 Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email: permits@ionsolar.com Reconnect only 67.84 2 CONTRACTOR _ Pump or irrigation circle 67.84 2 Business name: ION DEVELOPER LLC Sign or outline lighting 67.84 2 Address: 4801 N UniversityAve#900 Signalel, len or limited-energy 0 See Page 2 2 panel,alteration,or extension. City/State/ZIP: Provo, UT 84604 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(888 ) 781-7074 Fax:(801 )607-6826 Investigation(1 hr min) 90.00/hr Email: Industrial plant(1 hr min) 78.18/hr permits@ionsolar.com Inspections for which no fee is CCB Lie.: 230394 Electrical Lic.: C1524 Suprv.Lic.: 6098S specifically listed hr min) 90.00/hr ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: 1444,.8�►.w-..47 Subtotal: $63.60 Print name: David S Conrad Date: 11/4/2021 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): $23.66 Authorized signature: zgVlAo/tAm.Ai}f64A.1.6 TOTAL PERMIT FEE: $220.82 This permit application expires if a permit is not obtained within 180 Print name:Anastasia Heule Date: 11/4/2021 days after it has been accepted as complete. * Number of inspections allowed per permit. 1:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: 4. . ., ..- 447InfM, - Description Qty. Total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: 5 kva or less 100.70 2 Check Type of Work Involved: 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr s.ecificall listed '/z hr min {fi ",:l Subtotal(Enter on Page 1):., Fee for each commercial system: $75.00 Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems El Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\BuildingU'ermits\ELC_PermitApp_ELR_ERE.doe Rev 06/17/2015