Report / 6 r -- Bend Office (541)330-9155 Geotechnical Office (503)601-8250 Eugene Office (541)345-0289 Salem Office (503)589-1252 Carlson Testing, Inc. Tigard Office (503)684-3460 Daily Report of Proprietary Anchors / ) .2°492"1"— °Z Project: POLYGON AT ROSHAK RIDGE-L(7F 137 CTI Job#: T1804799•CD Address: 16693 SW SUNSHINE COAST TIGARD Jurisdiction: TIGARD CTI representative: Ken Jordison was on this site on date: 07/16/2021 to perform Special Inspection for Permit: MST2o21-00072 PO#: SCOPE OF INSPECTION Location of proprietary anchors inspected[to include grid lines,elevations 1. Checked in with superintendent or client representative: (floors)and drawing details]: OBSERVED INSTALLATION OF ONE 5/8"DIAMETER Name: ROB HOWSER THREADED ROD AT PATIO DOOR AND TWO REBAR Company: TAYLORMORRISON #r-io3(7DOW1) ND#GE:NERAL(5/1514)PER BULLETIN 2. Inspection was IBC Ei Continuous 0 Periodic PROPRIETARY ANCHORS Yes No N/A 1.Reviewed previous inspection reports? X 2.Reviewed evaluation report? X REPORT SUMMARY 1. Work inspected was: []Completed E In Progress Verified following items meet manufacturer's published installation 2. Completed work inspected 0 was was not in compliance materials. with Yes No N/A 3.Verified minimum embedment depth of the anchors? X X Approved plans and specifications Shop Drawings 4.Verified installation of the anchors? X C RFI n Design Change Submittal n N/A 5.Verified anchor diameter? X Doc.No(s): CT ENGINEERING Dated: 07/07/2021 6.Verified steel grade? X 7.Verified hole diameter? X 3. Noncompliance item(s)were noted this date,details on the following 8.Verified type of drill bit used? 7( page(s):El Yes n Non N/A 9.Verified hole cleaning method? X 4. Noncompliance item(s)were reinspected this date,details on 10.Verified adhesive application? X following page(s) Yes ❑No X N/A H.Verified edge distance? X' Conform ❑Remain in progress 12.Verified spacing? X 13.Verified installation torque? X Report(s)findings were discussed and left with ROB HOWSER Evaluation report number and date: ESR 4057.EXPIRES 4/22 of TAYLOR MORRISON Name of product being installed: SIMPSON SET 3-G Batch Number: 1000094415 Expiration Date: 06/09/2022 Based on the code,approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors and subcontractors. 0 See additional report pag(s) Distribute Attachment(s) Proprietary Anchors Version I Page I of I Bend Office (541)330-9155 Geotechnical Office (503)601-8250 Eugene Office (541)345-0289 Salem Office (503)589-1252 Carlson Testing, Inc. Tigard Office (503)684-346o Daily Report of Proprietary Anchors/1117-2 72/ 1' Project: POLYGON AT ROSHAK RIDGE-LOT 136 CT I Job#: T1804799•CE Address: 16705 SW SUNSHINE COAST TIGARD Jurisdiction: TIGARD CTI representative: Ken Jordison was on this site on date: 07/16/2021 to perform Special Inspection for Permit: MST2021-00054 PO#: SCOPE OF INSPECTION Location of proprietary anchors inspected[to include grid lines,elevations 1. Checked in with superintendent or client representative: (floors)and drawing details]: OBSERVED INSTALLATION OF ONE 5/8"THREADED ROD Name: ROB AT PATIO DOOR INSTALLATION APPEARS TO BE PER BULLETIN#GENERAL(5/14/14) Company: TAYLOR MORRISON 2. Inspection was IBC n Continuous 0 Periodic PROPRIETARY ANCHORS Yes No N/A 1.Reviewed previous inspection reports? X REPORT SUMMARY 2.Reviewed evaluation report? X 1. Work inspected was: 0 Completed ❑In Progress Verified following items meet manufacturer's published installation 2. Completed work inspected ❑X was ❑was not in compliance materials. with Yes No N/A 3.Verified minimum embedment depth of the anchors? X 0 Approved plans and specifications n Shop Drawings 4.Verified installation of the anchors? X RFI ❑Design Change n Submittal ❑N/A 5.Verified anchor diameter? X Doc.No(s): CT ENGINEERING Dated: 05/15/2014 6.Verified steel grade? X 7.Verified hole diameter? X 3. Noncompliance item(s)were noted this date,details on the following 8.Verified type of drill bit used? X page(s):El Yes ❑No N/A 9.Verified hole cleaning method? X 4. Noncompliance item(s)were reinspected this date,details on 10.Verified adhesive application? X following page(s)❑Yes n No U N/A 11.Verified edge distance? _ X n Conform I I Remain in progress 12.Verified spacing? X 13.Verified installation torque? X Report(s)findings were discussed and left with ROB Evaluation report number and date: ESR4o57 EXPIRES 4/22 of TAYLOR MORRISON Name of product being installed: SIMPSON SET 3-G Batch Number: 1000094415 Expiration Date: 06/09/2022 Based on the code,approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors and subcontractors. ❑See additional report paw(s) El Distribute Attachment(s) Proprietary Anchors version I Page I of I