PFI2021-00394 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
11111 a. COMMUNITY DEVELOPMENT Permit#: PF12021-00394
T I GAR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 11/03/2021
Parcel: SEG104
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE Job#M2887925
Project Description: PGE to replace/repair overhead wire
Class of Work: FEES
Type 1 -Utilities(gas,electric,data) Description Date Amount
PFI Permit Fee 11/03/2021 $300.00
Owner: Total S300.00
REQUIRED INSPECTIONS
Call 503-639-4175 for the IVR inspection request line or visit the City of
PHONE: Tigard website atwww.tigard-or.dov to schedule inspections online.
Contractor:
PHONE:
Applicant:
JASON MOXLEY
2213 SW 153RD DR
BEAVERTON, OR 97223
PHONE:5037186349
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant See application
Signature:
UNAdism
Issued By: a it
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
•
Conditions for PF120 2 1-0039 4
TVPe: Condition Name: Status: Seventy:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code,and the terms of any
agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and
violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and
suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs,pavement markings, mailboxes,etc.shall be
reinstalled or replaced,with like kind of material.Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways",U.S. Dept. of Transportation, FHWA,current edition,American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OUCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area.
Traffic control devices,flag persons,etc.,shall be in place prior to initiation of construction work and shall be effectively
maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic,at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area
wide Emergency Services:503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)and
503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice
Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at
each end of the construction area 72 hours(min.)before initiation of construction work.
PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times,including normal delivery service and mail service.Obtain City
approval of any access closures.
PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m.Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City
Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the
City Engineer.
PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 13-DRAINAGE CONTROL Applied Notice
Drainage shall be controlled within the work site and shall not adversely affect adjacent private property,public property and
the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective
drainage control.
PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080.Copies of said rules may be obtained from the Center by calling 503-246-1987. If
you have any question about the rules, contact the Center. NOTE:Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before
digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary,it shall be done at the
applicants expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with
affected utility agencies.
PFI_Utilities 16-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads,ditches,etc.)as may be necessary,as determined by
the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity,the applicant shall coordinate with the City's inspector,<Insert Name>at<Insert
Phone#>,to establish a preconstruction meeting.
PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work,prior to any staged inspection,
and after completing work covered by the permit.
Contact Ken Fisher at 503 816 1646 or Kenny@tigard-or.gov
PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance,and all attachments,and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms,conditions and
provisions and to the City approved permit plans,and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City,in advance of work
performance.
PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice
Applicant shall submit daily inspection reports,on a weekly basis,to the City's Inspector.
PFI_Utilities 23-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners,and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice
The City's Inspector may,at his discretion,require tests and or reports from the applicant to validate claims of material or
construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense.
PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector,in writing,the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems,take corrective action and,in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing,of any/all assignment changes.
PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice
Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed
easements,shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain
or provide for proof of right-of-entry or easements.
PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice
Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction
activity.
PFI_Utilities 28-AS-BUILT DRAWING Applied Notice
1,2,3,4,5 28-AS-BUILT DRAWING
One as-built drawing showing all new public improvements,including any revision made to the previously approved
construction plans and,also,any improvement which may impact an existing public system or facility,shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
1,2,3,4,5 28-AS-BUILT DRAWING
One as-built drawing showing all new public improvements,including any revision made to the previously approved
construction plans and,also,any improvement which may impact an existing public system or facility,shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and,also,any improvement which may impact an existing public system or facility,shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
PFI_Utilities 31 -OTHER Applied Notice
Other
City of Tigard• PFI#: 2021-00394
ENGINEERING DEPARTMENT
TIGARD Public Facilities Improvement (PFI) Permit
PROJECT INFORMATION TYPE OF WORK
Project name: PGE Job # M2887925 ® TYPE 1—Franchise Utility Work
Brief description of project: PGE to replace/repair overhead performed byNWN,PGE, or utility
agency
wire ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer
Work performed for the purpose of:
• Sidewalk installation or repair
• Driveway approach installation and repair
SITE INFORMATION • Sanitary sewer lateral installation and
9285 (AlS 70TH AVE main line tap
Location (address if available): ❑ TYPE 3—Full Scale Development Work
Tigard, OR, 97223 performed with land use approval which
includes any of the following
• Subdivisions or Partitions
APPLICANT INFORMATION • Street widening
Name: PGE [Briana Fogh for Jason Moxley] • Mainline installation for sanitary sewer,
c+
storm sewer, Tigard water, and Tigard
2213 SW 1 53rd Dr water service area
Mailing address:
City/State: Beaverton Zip 97003 ❑ TYPE 4—Small Cell Technology
503.463.4355 ID TYPE 5—Tigard Triangle
Phone:
Email: Crewcoordination-western@pgn.com Phone:
NOTE: Type 1 and 2 applications may be
Contact name: Jason Moxley emailed to rowpermitsa,,tigard-or.gov.
Phone: 503.718.6349 Email: Crewcoordination-western@pgn.com
CONTRACTOR INFORMATION El Same as applicant
Name: CCB Number:
Mailing address: City/State: Zip:
Phone: Email:
ENGINEER INFORMATION
Name:
Mailing address: City/State: Zip:
Phone: Email:
ADDITIONAL INFORMATION
Estimated value of work is required(if over$5,000):$ (within the public right-of-way)
Is work related to a LAND USE DECISION? ❑Yes r❑No Case number:
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 4
APPLICANTS
NOTE: Person specified as"Applicant" shall be designated"Permittee"and shall provide financial assurance for
work,if required by the city pursuant to TMC 15.04.140.
* With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant
are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner
or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this
application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application.
I,the applicant, certify that:
• To the best of my knowledge,all the information provided within this application package is complete and
accurate.
• The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the
subject property.
• If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
Briana Fogh 10/26/2021
Applicant's or authorized agent's signature Print name Date
Property owner's signature (if required) Print name Date
Case No: PF12021-003 4 Permit fee: 3019• `ry Received by: SPV Date: 10/26/2021
Approved by: • t 1514 C2 Date: /b .z 2 'z-/ Notified by: Al— Date: it ij (2021
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • ww'ttigard-or.gov • 503-718-2421 • Page 2 of 4
DEVELOPMENT ENGINEERING FEES
Public Facility Improvement(PFI)Permit:
INITIAL PFI PERMIT FEE
Part 1: Required submittal fee is 10%of the Net PH Permit Fee.See below for calculations.Minimum of$300.
NET PFI PERMIT FEE
Part 2: All non-water system improvements engineer's estimate X 7% (less the initial PH Permit Fee).
WATER LINE CONSTRUCTION FEE
Part 3: All public water system improvements engineer's estimate X 12%.
FOR STAFF USE ONLY FOR STAFF USE ONLY
TYPE 4: SMALL WIRELESS FACILITY TYPE 1—3:DETAILED SUBMITTAL
CHECKLIST REQUIREMENTS
Does applicant have a right-of-way license? ❑Yes 0 No TYPE 1 AND TYPE 2-Must include a sketch
showing:
Under the wireless facilities standards,is the proposal
❑ Dimensions
considered?(check all that apply): ❑Small Cell 0 Macro 0 Street Name
How many install sites are proposed as part of this permit
O Site Address
application?
TYPE 3-Must provide 4 sets of plans (sized 24 x 36
or 22 x 34) and an electronic version of all submittal
The proposed equipment is located on which of the following: items. The plans must that include:
❑Public Right-of-Way 0 Private Property
0 Cover—Site,Vicinity,Abbreviation,Legend
If equipment is to be located on private property,describe the 0 General Notes(City,Water,Sewer,etc.)
type&use: 0 Street(Plan,Profile)
❑ Water,Storm and Sanitary(Plan Profile)
O Water Quality Facilities
❑ Grading
❑ Landscaping/Tree Plan
❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,
Sanitary,Water,Signage,Street Lights,etc.)
❑ Details
❑ Traffic Sight Distance
❑ Signing and Striping
❑ Street Light Plan and Photometric
❑ Engineers seal/signature
❑ Sheet label(project land use name,revision and plan
log block,dates and sheet numbers.)
O Engineer's Construction Estimate
Additional Submittals
(per land use conditions,if applicable)
O Traffic Report
❑ Storm water Drainage Calculations
❑ Geotechnical Report
❑ Preliminary Access Report(Sight Distance)
❑ Proposed Plat
❑ Pathway Design
❑ Water Provider Approval
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 3 of 4
9 cIv •• 1_ '• s1
Edge of Pavement
U Ditch _F
Streetlight �• •�•�•. �' .r_•_
(i:N7Druth, •
T"31WP CS T IRS'r
r., I
•-r
nExisting House
I '- c I Existing 1
'i tr . Driveway
'' I
V
Ed
21 I i dit Pr1
iI
1 , ' I °, 1
bi ua 1 I 1
Existing Shop 1
Povrerpole I >11:1\
95' 1 D Frope[i ,17e .-- -.
—
1 -
4I
• Fire Hydrant(F N)
I I
Scale: 'I"=30'
I I
I I
I I
I
TYPE 1 AND TYPE 2:
MINIUM SKETCH REQUIREMENTS (Put N/A if not applicable)
North arrow Property lines&dimensions Existing utilities locations
(sewer,storm,water)
Street& street names All existing structures
Proposed work Existing curb or edge of pavement Utility&street light poles
Existing S/W or D/W apron Slope of property Trees
City of Tigard • 13125 SW Flail Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 4 of 4
www.invarion.com
Shoulder Work w/ Minor Road Encroachment Diagram 300
ROAD I
WORK 4 to
AHEAD
0
Initial
Warning A O
Sign
I °
o /
0
(Optional) 0
• •
0
0 —
0
—
Protection Vehicle o 1/\
w/TMA(both Optional)
See Chapter 4 0 Buffer
•
O
10' O
minimum O L13
0
O
I o
A
ROAD
NARROWS
B
It ROAD WORK
AHEAD
www.invarion.com
Shoulder Work wl Minor Road Encroachment Diagram 300
Use this detail for non-freeway work which extends into a travel lane and
maintains a minimum 10 foot travel lane. If a minimum 10 foot travel lane
can not be maintained, or when traffic can not safely pass by in both lanes
simultaneously, use the appropriate lane closure diagrams — for example,
Diagrams 310 through 350.
A lane closure may be appropriate for conditions such as high traffic
volumes, high speeds, and inadequate approach sight distance to the work
space, or heavy equipment adjacent to the travel lane.
1 . Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3 — Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCMS in caution
mode may be used.
3. Cones shall be placed along the entire length of the work space. If a
protection vehicle is used and work is in place one hour or less, the
taper and tangent devices may be omitted.
4. If the speed is 45 mph or higher, volumes exceed 2000 ADT, or there
is limited sight distance, consider placing cones or tubular markers on
centerline.
5. An arrow board in caution mode or truck-mounted PCMS with
"SHOULDER WORK" or other appropriate message may be used for
higher visibility.
Sign Spacing and Buffer Lengths (feet)
Posted Spacing Between Signs Buffer
Speed A B C Space ERRATA:
20 50
25 100 100 100 75 Supplement Table
30 100
Updated:February 12.
40 350 350 350 150 2016
45 180 By:ODOTTraffic-Raodway
50 500 500 500 210 Section
55 250
Signs Spacing and Buffer Lengths (feet) Supplement
Posted Spacin Between Signs "Buffer"
Speed A I B C Space
60 285
65 700 700 700 325
70 365
www.invarion.com
Bicycle Accomodation Diagram 5-6
1
NOTES:
- Bicycles on Roadway (CW11-1) sign should not
interrupt standard sequences. For example:
BE PREPARED TO STOP/Flagger Symbol
LANE CLOSED AHEAD/Lane Ends
Work Symbol
- Bicycles on Roadway sign typically follows ROAD
Area WORK AHEAD sign and used as general warning.
A
A
t
: ON
ROADWAY
w ROAD
WORK
AHEAD
www.i nva ri on.co m
Bicycle Accomodation Diagram 5-6
Bicycle Accommodation Principles:
1 . If a significant volume of bicycles can be expected and work closes a
marked bicycle facility, or requires bicycles to share a travel lane,
install a "(Bicycle) ON ROADWAY" sign (CW11-1 ) or the Bicycle
symbol (W11-1 ) sign with an "ON ROADWAY" (OBW1-5) rider, in
advance of the work area.
2. Install temporary signing off the paved shoulder, within the planter
(buffer) strip, or share the width needed between the shoulder and the
sidewalk, as available.
3. Signs are to remain in place until the surface is restored and the width
made available for bicycle use. See Diagram 5-6 for typical bicycle
signing placement.
Sign Spacing and Buffer Lengths (feet)
Posted Spacing Between Signs Buffer
Speed A B C Space
20 50
25 100 100 100 75 ERRATA:
30 100
Supplement Table
35 125
350 350 350
40 150 Updated:February 12.
45 180 2016
50 500 500 500 210 By:ODOT Traffic-Roadway
Section
55 250
Sign Spacing and Buffer Lengths (feet) Supplement
Posted Spacing Between Signs "Buffer"
Speed A B C Space
60 285
65 700 700 700 325
70 365
i \ L PD-32 f/ LEGEND
SURVEY GRID BOUNDARY
_Remo v/ABANDON FACILITIES_INSTALL FACILITIES
9120 9108 Mil MODIFY/TRANSFERANSTALLADDI7IONAL FACILITIES
POLES
4332
40'-e POLE CLASS(1,2,3,4,H1,H2,S)
2052 C 1549929 HT-CL
I---POLE HEIGHT
FRAMING TRANSMISSION{DISTRIBUTION(SEE CODES BELOW)
9160
•EE TRIMMING NOTES:
4834 SW'TALL TREE BRANCHES FOR
y CREW TO ACCESS ENTIRE SPAN PLR
19 C 02 4836-PL47884
'140
7145 6
u C
Z
O O OO
3
to
4835
e.225 1949 C 25 37796
9e5 rJ
U
4836
40-4
® 1949
7115 Baas CSO 8851
104 REPAIR LASHING ON
2019 nknawn SPAN,PLJ74636-PLR7884
VICINITY MAP
136,
Rpen 78M —
- .110415 4a4 swA«,,,4,
E11957 „-:
B 8339 i`p V . 140
G./ F GAkD N,HOME
rl ■ 6WY"mr
Z
J -325 YYV•
91
z 9350
n3PD-93 25 Open ,.. -r.. 4'L_o
D3 9355
'6'-Unlnown .wdntl� n=
2016
9390
ram
vim'.,. 749
C 50 8434 c ,wtv.^s,
sw
SW ryl rr
7a10 a783 o w ` ' -WCBtT PORTLAND •^f
SW SHADY LNSr y �949 ,r �„ �.
., .9 re 1 .. -
2OSuy L 5010783 (`8 .:.-
Pr• J ii
10:19 9425
VN(-fix 9445 1 rws„� Sources'Esn, EME Ga.NRi28SGS..
16-Unknow ImermRap,INCREMENT P Wean.Lori
7C7D 6 7040 9465 JaparR MET L Esd China(Hong Kong),
Eon rea,Fvsh(Thal lore CC,(c)
0 35 7 140 Feet Tw, 0099 treelMap coninbulors,'a and the
I I I I I I I I I GIS User Commu nity ,
PGE CONSTRUCTION DRAWING
AS-BUILT VERIF/CA TION d NESC VIOLATIONS CORRECIhD
�hmoa.cnn nC,9( -
Foreman: Date:
THINK General Foremen: Date:
SAFETY (Signature 4,IyrequiredFrankIconstr9�„chans,s.)
SOPMIENG REVIEW.' IASBUILT BY DESIGNER:
-- FIRST bAh. SCALE' ACCOUNT WO OB NO
ANYDEVLATTON FROM THIS DESIGN MUST / 8/5/2021 tin=70ft 1070001 10000017443 M2887925
�BEAPPROVED BY THE PGEPRO/ECT MANAGER_ ' °TIE 05-2020 OH FITNES REPLACE SECONDARY CONDUCTOR
CIRCUIT SIZE
ATTENTION CALL 811 BEFORE YOU DIG /` CORNELL-WES7LAW N 111 x 17
OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED ��//��. LOCATION
BY THE OREGON UTILITY NOTIFICATION CENTER. irV 9285 S W 70TH AVE,TIGARD 97223
THOSE RULES ARE SET FORTH IN OAR 952-00I-0030 DESCRIPTIONLASHING WIRE REPLACEMENT/REPAIR @ POLE
THROUGH 952-001-0090 YOU MAY OBTAIN COPIES OF -� r LL \ C1125D 4836
THE RULES BY CALLING THE OREGON UTILITY f COUNry SECTIONS WORK WITH SHEET
NOTIFICATION CENTER ADMINISTRATION#(502-232-19ST WASHINGTON C1125D 1 OF I
TO REQUEST UTILITY LOCATES CALL THE OREGON BRONpw�hatS below. rEa0N DESIGNEE PHONE DRAWN BY '
UTILITY NOTIFICATION CENTER,811AT LEAST Gail beam you dig. N C.6."1V0D JASON MOXLEY 503.718.6349 Christian Schumann-Curtis
3 BUSINESS DAYS PRIOR TO EXCAVATION ...war.,oxnmm 0 PORTLAND GENER°I ELECTRIC CO.-ALL RIGHTS RESERVED