Loading...
PFI2020-00053 Vo City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT ■ Request for Permit Action - 13125 SW Hall Blvd. • Tigard, Oregon 97223 . 503-718-2439 • www.tigard-or.gov TO: CITY OF TIGARD Building Division 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503-718-2439 Fax: 503-598-1960 TigardBuildingPertnits@tigard-or.gov FROM: ❑ Owner ❑ Applicant [/Contractor ❑ City Staff Check(✓)one REFUND OR Name: INVOICE TO: (Business orIndiiddual) Henkels & McCoy Attn: Tammy Munger Mailing Address: 10001 SE Sunnysidp Rd City/State/Zip: Clackamas, OR 97015 Phone No.: 503-313-1430 PLEASE TAKE ACTION FOR THE ITEMS) CHECKED (✓): ® CANCEL OID PERMIT APPLICATION. PERMIT FEES (attach copy of original receipt and provide explanation below). ❑ INVOICE FOR FEES DUE (attach case fee schedule d provide explanation below). Permit #: 1°F120z.0 –000.63 .11oz Site Address or Parcel#: Across the street from 9600 SW Oak Project Name: POR-27998-BARROWS FDH HUB H1010 Subdivision Name: Lot#: EXPLANATION: Our client has decided to place their cabinet on private property rather than in the public ROW, so this permit is no longer required. Signature: j Date: 2/18/2020 Print Name: Tammy MunqWr Refund Policy 1. The city's Community Development Director,Building Official or City Engineer may authorize the refund of • Any fee which was erroneously paid or collected. • Not more than 80%of the application or plan review fee when an application is withdrawn or canceled before review effort has been expended. • Not more than 80%of the application or permit fee for issued permits-prior to any inspection requests. 2. All refunds will be returned to the original payer in the form of a check via US postal service. 3. Please allow 3-4 weeks for processing refund requests. • ' OFFICE USE ONLY Route to Sys Admin: Date —m7, Route to Records: Date Z (v B Refund Processed: Date B Invoice Processed: Date B Pemrit Canceled: Date 13LC Parcel Tag Added: Date B 1:\Building\l+orms\RegPeriltAction_ 20 8.doc RECEIVED I __ City of Tigard FEB 0 6 2020 PF #: ZO Q,�-�10t1 s ENGINEERING DEPARTMENT CITY OF TIGARD Public Facilities fmprdEffff�&''fit (PFI) Permit PROJECT INFORMATION TYPE OF WORK Project name: POR-27998-BARROWS FDH HUB H1010-SW OAK ST&SW 95TH AVE x TYPE t—Franchise Utility Work performed by NWN,PGE, or utility Brief description of project: We are open trenching from existing manhole on SW mac, Oak St 45'to bark of sidewalk in front of 10300 SW GreensbuEg Rd and placing a 48"MfIN36" ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer Work performed for the purpose of HH Mounting Pad with Convergence Cabinet. • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and main line tap Location (address if available):Accross the street from 9600 SW Oak St ❑ TYPE 3—Full Scale Development Work X6 US performed with land use approval which includes any of the following: • Subdivisions or Partitions APPLICANT INFORMATION • Streetwidening Name: MClmetro Access Transmission Services • Mainline installation for sanitary sewer, storm sewer, Tigard water, and Tigard Mailing address: 2550 NW Aloclek Dr water service area City/Stats: Hillsboro,OR Zip: 97214 ❑ TYPE 4—Small Cell Technology ❑ TYPE 5—Tigard Triangle Phone: Email: Phone: NOTE: Type I and 2 applications may be Contact name: Wendy Schwimer I emailed to rowpermits@tigard-or.gov. Phone: 503-403-5143 Email: Wendy.Schwimer@Verizonwireless.com CONTRACTOR INFORMATION ❑ Same as applicant Name: Henkels and McCoy Contact:Tanya Boyd CCB Number: 63699 Mailing address: 10001 SE Sunnyside Rd City/State: Clackamas,OR Zip: 97015 Phone: 503-680-5919 Email: Tboyd�henkels.com ENGINEER INFORMATION Name: Mailing address: City/State: Zip: Phone: Email: ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ (within the public right-of-way) Is work related to a LAND USE DECISION? ❑Yes ©No Case number: City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.dgard-or.gov 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owners signature on the application. I,the applicant, certify that: • To the best of my knowledge, all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted, I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. �e Tanya Boyd 02/06/2020 Applicant's fft audio ed agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY Case No: Permit fee: . Jd D. 0-t' Received by: Date: �A6 774 Approved by: Date: cZ- 1 —1.0 cLO Notified by: SC Date: 2'1 Z"Zd 14 City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.dgard-or.gov • 503-718-2421 Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR ONLY • ' STAFF USE ONLY TYPE 4: SMALL WIRELESS FACILITY TYPE 1-3: DETAILED SUBMITTAL REQUIREMENTSCHECKLIST Does applicant have a right-of-way license? ❑Yes ❑No TYPE 1 AND TYPE 2- Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered?(check all that apply): ❑Small Cell ❑Macro ❑ Street Name How many install sites are proposed as part of this permit ❑ Site Address application? TYPE 3-Must provide 4 sets of plans (sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: ❑Public Right-of-Way ❑Private Property ❑ Cover—Site,ti'icirury,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes(City,Water,Sewer,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water.Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineers Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval Cityof Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 • Page 3 of 4 I I Edge of Pavement Streetlight I �_ Ditch �� i T--P opos dS L�rTine 1 1 I 1 V Existing House 1 as ( ' rve so Dnewdp vi I 1 CI w CO o� �I '• � I 1 o� • 3' I � Existing ,II?p r Powerpole \� i3 I la 95' I FropertyLne-------.-- Fir.Hydrant(FH) Q II 1 Scale: 1"=30' � � I TYPE 1 AND TYPE 2: MINIUM SKETCH REQUIREMENTS (Put N/A if notapplicable) � I I � 1 1 � I I North arrow Property lines&dimensions Existing utilities locations (sewer,storm,water) Street&street names All existing structures Proposed work Existing curb or edge of pavement Utility&street light poles Existing S/W or D/W apron Slope of property Trees Cityof Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www..tigard-or.gov • 503-718-2421 • Pdge 4 of 4 MCI METRO XO PORTLAND - SW LEG SW MULTNOMAH &GARDEN HOME RD TO 9215 SW NIMBUS AVE TIGARD, OR SHEETINDEX No. DESCRIPTION CONTACTS dNH6 COVER 2 GENERAL NOTES H&M ENGINEERING ` "' 3-22 PH45E1-14 (WASHINGTON COUNTY) PH: 503-758-7227 swmrNeoEEsoN 23-32 PHASE 15-21 (CITY OF TIGARD) 33 PHASE22 (ODOT) 34 PHASE 23 (CITY OF TIGARD) 35-37 PHASE 24-26 (CITY OF BEAVERTON) u,15 SN 41MBUS AVE �r5 r serf rV�r MCI 21D66WNMAfiUS m7N&O6 Im 61Y GR N U Gd CASCADE SNSHA Y&WHAVE t . VICINITY MAP • CASCADE FIBER SERVICES TWN: DIAL QQ 11 W ® PO BOX 739 NG RNG TEMPORARY LONGVIEW,WA 98632 SHT PH: 360-6074673 TRAFFIC CONTROL CALL LOCATE 1 hffps:ticfspnw.com ® BEFORE YOU DAWN: TPOTE PLAN DIG OF 37 slarson@cfspnw.com SCALE NONE DATE: 11-948 TRAFFIC CONTROL LEGEND CONSTRUCTION NEWS: IDoow-6:OOAY 9:000 TO 3:DOPM FLASHING ARROW BOARD VAV UGHT STATION(NIGHT) BARRICADE ;;. CONTRACTOR SHALL NOTIFYE�MGGER(RAL CERTIFIED) PROPERTY OMNER 14 DAYS IN 111 TYPE 2 BARRICADE ADVANCE OF DRIVEWAY CLOSURE TRAFFIC 9CIIAL —TWE 3 BARRICADE TRI-MET BUS STOP IMPACTED NOTIFICATION IS ��.W REOUIRED AT(503)962-4949 AT LEAST TWO 1 HIGH LEVEL WARNNG DEVICE —K-RAR WEEKS PRIOR TO CONSTRUCTION AND MUST BE ACKNOWLEDGED BY TRI-MET DISPATCH y MOM SIGN ® WORK AREA M TRAFFIC SMS!W/STAND PHASE# 15 CITY OF TIGARD 63, eta '� ; v ` r b' 158' 03' IaD' Oar BUFFER SPACE 5161NG TAPER v: b b b ' b 1'MIN.LANE b SW OAK ST 8 25 MPH OJ N POM WORM w2o-I WN. XO PORTLAND - SW LEG DIAL CASCADE FIBER SERVICES SEC: PO BOX 739 RNG: 811 LONGVIEW,WA 99932 PHASE 15 SHT PH: 3604074673 CALL LOCATE 23 httpWJ/cdp".Com 300 60 SW GARDENHOME RD TO SW NIMBUS AVE BEFORE YOU DRN:T POTE TIGARD,OR Wlaroon�icisprrw.com SCALE: 1'=60' DATE:11/2/2016 DIG OF 37 SFA I..- ia v 1, MATCH TO PROJECT NORTHLOCATION MAP FIB:BUR::54117308 CITY OF TIGARD LT MCI FIB:BUR::54117307 BARROWS-H1010 PLANNING/ENGINEERING FIB:BUR::54117004 SW OAK ST&SW 95TH AVE FIB:BUR::54117194 COUNTY AASHINGTON CITY: TIGARD CONST.WIG# WIFP.IIW SITE NAME s y - CRAWRING TIGARD w I _ U z r yi ' FDH LAIZ Z fw 45.4442 O ,"ka - PL4N A _122.7754 - 20 N Z V �•,,, -_ svallwes.orseReL N d'W O O U�O> z w U 2 z m a m I ~ O En U) U O I. ENGINEER.Neasuo DRAWN BY'HBOLSfAD SCALE: RWSION' - SHEET y OF to eYw RAIL THF.o`RAAININC`SAxon" sKCigCnPEMAN LIF CONTACT LIST ' PORTLAND,OR HMA ENOINEEIBMD CONTACT TRACTPATRICK OID: H M EMAIPHOL PMASRKS®HENKELS LOM • 8W CONTRACTOR MAa1 MF0: CONTACT'MARLON BOLSTA0.TEKSY8TEM5 PMAR, 8O2M;Z EMML MBOLSTAD®TEK8r8TEMs CON � Knowwhat'sb010w. 0811 before you dig. FILE ANAowsxmloaN..min.: TABLE OF CONTENTS MCI 1. LOCATION MAP COUNTY W IiINGTGN 2. TABLE OF CONTENTS CITY LGARD 3. PERMIT LEGEND CONST SITE NAME 4. GENERAL NOTES CRAWRING TIGARD 5. MCI OUTSIDE PLANT FOCUS 6. UNDERGROUND CONSTRUCTION DETAILS 7. HANDHOLE & OR MANHOLE TYPICALS Z 8. FDH DETAIL > o w 9. PROJECT SUMMARY SHEET > 0 10. CONSTRUCTION SITE PLANS .0 0 Z m N d Ua N - U 20> K 2z Q 5 m m a LL X O w w F— o J V) FF w o U U Q ENGINEER'Ix TAD DRAWN BY.MBgSTAD SCALE: REVISION: SHEET 1 Of io w..aE onexmst a eveEw�iorssw��a w.e mwE izI -MP]EME�N WEV W HSM 41�M/'mP Gm CC LEGEND M LINEIYPES SYMMS INFORMATION TABLES AERML NEER-om-IND ® RISER-EXISTING AERIAL FIBER-ATTACH RML � ® TRAHSIISSI011/CNlR STR10N POLE UTILITY Of INFORMATION TABLE COUNTY: TDN AEFeER-OhWJSX RIS ( ER-PROPOSED EASIMG UIIITY O-0 (AUROf A AITACWWNIS WY VARY) LILY: TIWRD BORE- EXISTINGCATCH BA$M/MIET(RECTANGLIM) O TRANSMISSION POLE F'ROPDSED AiiAfE r.-r.' CONST.VIVO WI PALM BORE- PROPOSED SITE NINE STRAND-EXISTING CATCH BASIN/KET(ROUND) Op DISIRRIUDON POLE It SEOUENTK IN/DDI CALLOUT STRAND PROPOSED YAII: CRANIRING nenPn OMIT-EXISTING PRE HYDRANT .���. GRWNO/BONG CONDUIT-PROPOSED ." WATER/OAS WYE 0* � SEOUENTLAL N/TNL CWLOUT NNERD1UCT-EXISINC LOCO POST C><o AERIAL STORA4E - EXISTING NffRWCT-PROPOSED GAS STREET LIGHT C>Q ABIAL STORAM-PROPOSEDTALL SEQUENTIAL Vi/OIR CALLOUT U) -. WATER U TELEPHONE cx� TRAFFIC LIGHT ARM O VMAT/BI.IDNG SMAOE-ENINGZ nom OPTIC w P: LEI ELECTRICS j TREE O :',i a,n I,PINI c'Oae6 IROPDSEC W U j Sm SAINTARIf SEWER cl� Of STORM DRAW ( J CULVERT POLEpNC�/�GUY-p� HATCH PATTERNS Z 0 0 IN STEAM N —{ POLE ANCHOR/DOWN GUY-PROPOSED m a zo a WWI wu UNKNOWN UINIY BRIDGE - DOWN GUY TO EIOSTNG ANCHOR-PROPOSED O OIL > I- O PENCE �� SPLICE POINT-FUSING U U)U¢ Z W RN?Rf a WAY STREET SIGN CONCRETE SDEWALU A�LLL m ►� SPLICE PONT-PROPOSED Q m LL I.L. ------------ K w .. EDGE Of PAVEMENT FACE OF CURB ;' ADA RAIIP TERLIPA71M-EXSRNG TE _ ~ W CENTER LIF F® PJLLBO%- DUSTING POLE -EKISTING C' TERNRUTION- PROPOSED In 1- PB T�S/YE4TATION VINN U O AB R IATI NS ® UIRMY POLE -PROPOSED ❑ L) ASW ASPHALT SIDEWALK .9 ARNCIIOH BOX PUILROX - PROPOSED Q BIP BUCK RON PIPE YH MANHOLE TRVFC RATED VAULT-EXISTNS _ BSP BLACK STEEL PIPE MP WE POST (SIZE AND LRIUTY TYPE WY VARY) O CONSTRUCTION NOTE/RESTORATION LALLOUT CSW CONCRETE SIDEWALK 0/S OFFSET CTL CENTURY LINK P/S PARER STRIP �: TRArFX RATED VAULT-PROPOSED #� PHOTO-MARKER D/W DRIVEWAY PR POWER BSER (SIZE WAY VARY) ENGINEER:MB,X MAD ELECT. ELECTRIC PK POLY Y►M CHLORIDE NIZE AND-EXSIwO DRAY N BY:A KWO EDP EDGE OF PAVE" RGS RNID GALVANIZED STEEL CONDUIT (�E'�UlRlfi'TYPE W7 VARY) NDRIFI APRON SCALE: Ns EOTW EDGE OF TRAVEL 1M7 ROW RW or WAYFiH HANDHOIE-PROPOSED REVISION: - (SIZE WY VARY SHEET OF Ao FOC FACE OF CNB SEW SAMPARY SEWER 1 21" MN SPAIN vHEET—_Z—r�rwx F/O FHR OPTIC SO STORY CUM PEDESTAL - EXISUTILITY TGceNAxnc.+AArsreRnwranro (SIZE APE UTRTII'TYPE WT VAR!) c.rmaauAA PeN�w TSA NOPE NIGH DENSITY POlYE1HYLElE STA STATION PED SKNIL eEl�r,b�o, PEDESTAL-PROPOSED oANOEnwawn.A N�.• hN HAND1HOlE SN SIFAW P (SIZE WAY VAN) nirrnco aeo�aPnxv rovrsrta�A-.mincN TEL TELECOM WET UTILITY YAN10T -EXISTING VAR (SIZE AM UTILITY RreVARY) E wr V( .._ BORE PO -PROPOSED BORE wr VARM UTILITY POTHOLE <A�WAI•WI , BORE wow-PROPOSED (SIZE LMr VWY) FILE A.AAONsniemm.wmAe GENERAL NOTES GENERAL NOTES THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE.HENKELS AND MCCOY.INC.HEREBY DISCLAIMS ANY RESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREA COVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THE LOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION. COUNTY: WASHINGTON 1. ALL MATERIALS,WORKMANSHIP,AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTION REGULATIONS AND APPLICABLE CITY: TWFD STATE AND FEDERAL REGULATIONS,WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS.OR ANY APPLICABLE STANDARDS,THE HIGHER QUALITY STANDARD SHALL APPLY.ALL WORK WITHIN PUBLIC R.O.W.OR EASEMENTS CONST.WNOS WIPP-11X MAY REQUIRE INSPECTED AND APPROVED BY THE LOCAL JURISDICTION INSPECTOR.INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER. SITE NAME ooA"8 2. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES,AS SHOWN ON THESE PLANS,IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND.WHERE POSSIBLE,MEASUREMENTS CRAWRING THOABo TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE.THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST lI HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES.THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS,ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIAL UTILITY CONFLICTS.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES.THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST{S HOURS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED. (n W <.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL OF SERVICE. AND ALL IRIUTO COMPANIES WITH REGARD TO RELOCATIONS ALL ADJUSTMENTS TE EXISTING My UTILITIES DURING Y UTIUTY SERVICE TO ASSURE THAT THE WORK (� IS ACCOMPLISHED IN A TIMELY FASHION.AND NRH A MINIMUM DISRUPTION OF SERVICE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF AVIV UTILITY SERVICE Z W 5. THE CONTRACTOR SHALL HAVE ONE(1)SIGNED COPY OF THE APPROVED PLANS.ONE(1)COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS.AND ONE(1)COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB W OU ~ ON-SITE AT ALL TIMES (n 0 Z Z a 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING,BUT NOT LIMITED TO.EXCAVATION,TRENCHING,SHORING.TRAFFIC CONTROL,AND SECURITY. O O In V _ Z ]. IF.DURING THE CONSTRUCTION PROCESS,CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR,HIS SUBCONTRACTORS.OR OTHER AFFECTED PARTIES WHICH GOULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR ID (L O D. SPECIFICATIONS,THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY. O; L) 0 e. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE. Z V Q g W m gED D LL 9. FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION,THE CONTRACTOR SHALL SUBMIT TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D.FOR APPROVAL.PRIOR TO ANY CONSTRUCTION W LLL ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAV,THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDINGANY AND ALL TRAFFIC CONTROL DEVICES AS MAYBE REQUIRED BY SAID PLANS,PRIOR TO INSTALLATION A PRE-CONSTRUCTION O J CONFERENCE SHALL SE HELD WITH LOCAL JURISDICTION FOt H 10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS 6HONN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED,INSTALLED,CONSTRUCTED. Lu REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE. L) O 11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING Q RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALL TUES. 12.DIMENS IONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING.FOR ADDITIONAL INFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS. 13.ALL EROSION AND SEDIMENT CONTROL(E.S.C.)MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY.ALL E.S.C.MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING. ENGINEER:NKUSTAD 14 ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTION ENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS. DRAWN BY:NIKI4T p SCALE: m 15,ALL CONSTRUCTION OPERATIONS,INCLUDING THE WARMING UP.REPAIR,ARRIVAL,DEPARTURE OR RUNNING OF TRUCKS,EARTH MOVING EQUIPMENT,CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE REVISION: LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION. SHEET OF i0 vavr w wv N oMRwE Pmriooen rccnnPcr,nwovwwewo murorwwwL Euw�rre a uamuuLPr rue ne mm Eweaeou fM Erf£YBNWLrME GRO.MI®KN BIr wlFWre6lPCNer>B� BfGi A FILE.wives xeiooe A+srrrnA MCI OUTSIDE PLANT FOCUS MCI. FIBER OPTIC CABLE UNCOVERING SYSTEM MCI OUTSIDE PLANT CONSTRUCTION GENERAL REQUIREMENTS CWNTY- MSHNGTM CRY. TGARD CONST.WHO. WlFP-IIM SITE NAME 1. THE TITLE OF THIS PROGRAM,F.0C DS,ANACRONYM FOR'FIBER OPTIC GABLE UNCOVERING SYSTEM,-WAS SELECTED •ALL FEDERAL STATE AND LOCAL SAFETY REGULATIONS MUST BE FOLLONED WTHOUT EXCEPTION. CRAMPING TG/.RD TO REMIND EVERYONE INVOLVED W TH VARKING NEAR MCPS ACTIVE FIBER OPTIC SYSTEMS TO FOCUS ON PROTECTING THEFACIUMES.IF,WRING THE COURSE OF THE PROJECT,YOU NOMCEANY ACTIVITYVkHlCH WYJEOPMDIZETHE • PERSONAL PROTECTIVE EQUIPMENT APPROPRIATE FOR THE SPECIFIC WORK SITE SHALL BE USED AT ALL TIMES. MCI OSP FACIUTES,IT IS YW R DUTY TO STOP THE WORK ANDRE{O L U.S. ATA MINIMUM,HMD HAT.SAFETY SHOEMTEEL-TOED BOOTS,AND FLORESCENT ORANGE OR GREEN WORK VEST ARE REQUIRED UPON 9WERING ANY MCI WORN(SITE. 1 F.0C.U.6 RULES MUST BE FOLLOWED ON ALL MCI MO.ECTS INVOLVING MORK ON OR NEM MCI OSP FACILITES. SAFETY IS MG'S NUMBER ONE PRIORITY.EVERYONE MUST REFRAIN FROM UNSAFE AND IMPROPER PRACTICES. • USE OF INTOA VMS,DRUGS,IHULAfTS OR ANY OTHER SUBSTANCES THAT MAY IMPAIR ALERTNESS ARE STRICTLY PROHIBITED. U) 3 REVIEWOFF.00.U.S.ISNMNDATORYATEV WARE-BID,PRE-OON3RUCTTONSITEMEETNGANDCLULYTALC•ATE uJ MEETING.F.0C.U.S.DISCUSSION MUST INCLUDESITESPEGFIC HISTORY,UNIQUE PROBLEMS,FACILITY • CONTRACTORSME NOT ALCYYED TO CUTANY CABLE.CABLESSCHEODUEDFORREMOVALWU.BECUTWMCI CONFIGURATIONS THAT MAY BE ENCOUNTERED,AND PAST ERRORS'TOSS VMO DO NOT LEAN FROM HISTORY ARE OPERATIONS PERSONNEL,AND ONLY AFTER VERIFICATION THAT ALL TRAFFIC HAS BEEN OFFLOADED. V Z DOOMEDTOREPEATR.-DONOTLETTIISNAPPENTOYW > O • EXTREME CAUTION MUST BE USEDATALLTIMESVNIENVAMKINHON ORNEMACTIVE CARIES.MMCIEMPLCVEE X p: W A ANY MORK NEM OR REQUIRING HANDING OF MCI OUTSIDE PLANT FACIUTMS CM ONLY BE PERFORMED VBITH M MO OR CONTRACT REPRESENTATIVE MUST APPROVE AND BE PRESENT PRIM TO AND WRI NG ALL CABLE HANDLING W VH- EMPLOYEEORCONTRACTREPRESENTATIVEPRESENT-THE MEANS OUT OF HS OR HER VEHICLE AND DIRECTLY ACTIVITIES. 7 MONITTORI TING CABLE LOCATOR CHECIIMD FOR Z) n A CURACNEVERYDAVPRIORTOCOMMENCEWWOFNORK(C MIEM THE EPRESENTATIVE MST HAVE A SONOFULY RNEMDDEPTHR NWMACTUAI . TOOLS ANDEWIPMENT 9FECIFlCALLY DESNGNED FOR TIE JDB ATFWND ME REWIRED.USE THE PROPER TOW Z Z Icr UNE ANA OEPTI OF THECMlE7. FORTIEJOB. O O O U 5 LOCATEANDPOTHOLEREWIREMENS '•Fn N •COMMIIVOLVINTVECAREOUIRESSPMALZEDTOOSSFEGFICAI.YDESGTOACCESS Q' O2 d MMACTES • PRIOR TO ANY EXCAVATION,THE MCI EMPLOYEE OR CONTRACT REPRESENTATIVE MUST VERIFY THE INITIAL cNc LOCATE MAAI(S COMPLETED RY NAG OPERATONB.DONOTTRUSTLMATERESULTSWMP MDBYOMMS! G O> ~ 2• TIE MCONTRACTWMESENTAVWMMTLOCATETHECABLERU WUWBYMAGNOATLEAST • TEMCTING Ma IMPORTANT IES IS EXTRATR EEMELECTPoRTANT,HOV&lE SAFETY REGARDING YOURSELF AND CTERS IS V U)0 Q ZQ W ONEPASSINEACHDRECTION.LOCATE RESULTS MUSTTIEN BE COMPARED WTH PRENCUS MARKS AND Z J m TIE SLBUILTS m d LL • IF THE PROPOSED WORK INVOLVES DIGGING OR EXCAVATING WTHIN 3 FEET OF THE CABLE,THE CABLE F J ROUTE W LL BE MARKED CONTINUALLY W TH ORANGE PAM AND SUPPEMENTED BY MAR ER FLAGS PLACED F EVERY 10 FT.THE EXCAVATION CONTRACTOR MUST POTHOLE(ALL POTHOLES MUST BE COMPLETED BY HAND DIGGING OR VACUUM EXCAVATION)A MINIMUM OF EVERY 15 FT..THEN EXPOSE THE ENTIRE LENGTH OF THE V) H H CABLE BY WAND DIGGING OR VACUUM EXCAVATION W 0 • IF THE PROPOSEDW INVOLVES DIGGING OR EXCAVATING WTHN S FEET(BUT NOT CLOSER THAN 3 FEET V OFT£CABLE,THE CABLE ROUTEHALLBE MARKED CONTINUALLY HATH ORANGE PANTAND SUPPLEMENTED O BYMMIERFlACaS RAGED EVERY IO FT.TEEXGIVATONCONTRACTOR FOTDLETHECMLEA Q MINUMNM OF EVERY 15 FT. • IF THE PROPOSED VARK INVOLVES DIGGING OR EXCAVATING YYITIHN 15 FEET(BUT NOT CLOSER THAN S FEET) OF THE CABLE,THE CABLE ROUTE HALL BE MARKED CONTINUALLY HATH ORANGE PANT AND SUPPLEMENTED BY MMIER FLAGS PLACED EVERY 10 FT.THE EXCAVATOR CONTRACTOR MUST POTHOLE THE CABLE A MI MMUM OF EVERY W FT. • THE CABLE W LL ALSO BE POTHOLEDATMY CHANGE IN THE RUNMNG UNE CA MORE THAN 1 FT.IN MY ENGINEER.463-STAD DIRECTION.AIYTME TE ACCURACY OF THE ELECTRONIC LOCATE IS QUESTIONED,OR THE MARKED RUNNING DRAWN BY.MSCISTAD LINE DOES NOT MATCH THE AS-GUILTS. SCALE: 6. EXPOSING REQUIREMENTS. REVISION: • N WCHUNFXEXCAVATIONWTHNSFT.WOSPFACIUTIESWLLBEALLONEDUMEWS EFAGUMM SHEET�_ OF to HAVE FIRST BEEN PROPERLY LOCATED,POT OUEQ POSITIVELY IDENTIFIED.CONTINUOUSLY EXPOSED BY FUND DIGGING OR VACUUM EXCAVATON,AND THE FACILITES ME CLEARLY VISIBLEEl _ •IN ADDITION,MECHANICAL EXCAVATION WTIN 3 FT.OF OSP FACILITIES REQUIRES NS IRES OITE PRIOR APPROVAL s�i<Bs.eo�BE-11 E�. FROM MCAS EMPLOYEE OR CONTRACT REPRESIENTATIVE ETFBLfIFoFA" T. PLEASE REFER TO THE LATEST EDRI0IN OF THE MCI OSP HANDBOOK FOR ADDITIONAL DETAILS.)NOW IT AND c ui Tiwncnriri".vm rtry FOLLOW R. H�V1 AF�YF/vF cu FILE N,Bnam xiu�a un•snx.e MCI UNDERGROUND CONSTRUCTION DETAILS COUNTY: WASHINGTON CITY: TIGARD CONST.WON WIFP-11. SITE NAME MO OAKI CRMMING TIGARC TYPICAL DETAIL RX TYPICAL DETAIL"B" TRENCH PLACEMENT SIDEWALK CROSS SECTION CONDUIT(S).HDPE(S)OR DIRECT BURIED CABLE. (p I W A'MN. , O d r W1 ' OPAVEUSAM sm EASE WVFIMARKER TAPE B' FOR LEVEUNG GRADE (� O -BURIEDCABLE Z Z � COVER, MARKER TAPE O C) Al MIN TMIN COMPACT BACKFILL O N Z COVER, INTIAYERS CO a Q. O a NNERWCT(5) T o W V O I MIN. F- AS 9 ORM�I cUc U Q QZQ LU CONWIT,ASSPECRIED TMIN. — - CIFAH BACKFILL C Z m J m FIBER CABLE —COMMIT AS SPEGFIED Q R LL 17 MN W W F � J j H NOTE BACKFILL MST BE MADE WITH ROCK FREE MATERIAL � O U Q TYPICAL DETAIL"C" TYPICAL DETAIL"D" CORE BORE PLACE HDPE ENGINEER:MBOI NOTE: EPOIIY GROUT ISUSEDAT BOTH ENDS OF DRAM BY:4801 CORE BORE M SEAL SLEEVE AND NPE -EUSTIW GRADE SCALE. INF REVISION: SHEET��a�a Ie I -I Of �cn�vsH N«i - CONCRETE MANMOFE,WALLETC.— 4.11E� 1 Oc .. WALL CORE BORE - µH111 EM C4VE SIO WP.GRC SLEEVE—L EPoAIED INTO CORE BORE CO ASSFECIFIED MAN!NUMBER OF © INNERMCTANDIOR HWEI.AS SPECIFIED L FIBER OPTIC CABLE ppY� Co^ FIF NAv HIOLVOMpznH.- PAD MOUNTED FIBER DISTRIBUTION HUB DETAIL MCI COUNTY'. YAl9NINOTDN CITY- nWgD CONST.WIOt K6v-nx UTENAME DETAILW CRANIRING HOARD DIPLODW ISOMETRIC DETAIL DETAIL"B' DETAIL'C' LOCKING DEVICE .LUSM MOUNT CROZIS,RECTION COVER DETAIL In LLI 9 Z WNK O w =O Z K ao N Z C m�aiE O \ 20> = 2to z0m g m m w LL O o w ww o � Fr� T - ENGINEER.MaAD ORAWN BY'NeasTno i. �MpE�lq � uo...nv SCALE. REVISION. F SHEET l Om ..r eEowcr o ev cc+�m�+.n[eE Ea..+v'+.e.nr. cFGRUTp{W.LL PEMnr..E 'rK AI EFD eB..6*�J IN gfiW..I di — JI �w.'Euo Brwl w.ee A )EA 0 xENKCUCEO.CAE0.M1l&Or(IR I.M secrom MOM" .y�N•p dpi PoSE'MTWf YCGMM41nEN Ob W ia�'MRCw WA& MlQNlMLT TO CdNTAI1. • 1'! � n�ww c. T nl 11 IObIQ. : RI as o••a•0.T IIn MT M9l9NEK � vvew wwv owFRs rD mAv� ', I:QR►11CKAWK i BILE....awE.,No�of....m.. PLAN VIEW FDH DETAIL I"ORT" ® MCI. OptiTect Local Convergence Cabinet coorvrr: wnsrlRc.or� CITY TIC RO CONST.MpOS MFF-11M SITE NAME CRANIRING nWD U) LU tis' U z w > z D O 13 a' 00 U rn U as'� meow ° a M%O> 00 w UNUa zw Mz m a in LL us w W F 0 J les rn D F rn D U O U a ° ° I I ° ENGINEER:NNM M ORANM BY:MBOtSTb SCALE' rvav H REVISION: SHEET OF IQ N WT NOnE WRWST 11EBE W/.'.xnG6 u0� T4B9WL4£ OflNift�YUYI 91RC�M.IIMRNO Q t= O Q Q FERxICIC.CCTSOPURp�r�'��' 432 FDH 288 FDH 144 FDH 41wY/m/C✓o C 'ILE eextiows nioioa�eewine PROJECT SUMMARY SHEET MCI PROJECT CLARIFICATION SUMMARY COUNTY: wABRINcroN CITY'. FGAR DESCRIPTION QUANTITY UNIT coesr.woos rr,BF-nx SITE NAME R,mo-pAKa CRAN/RING nGARo NEW 288 PAD MOUNTED FDH 1 EA 14'HDPE 45 LF 48 FIBER(TAIL FROM HUB) 1 EA 288 FIBER(TAIL FROM HUB) 1 EA V Z > O GEN 111 288 FDH WI10Y TAILS 1 EA ly w U w o PG4848Z539VM48X48X38 HH MOUNTING PAD 1 EA Z Z M 00 0 N U OPEN TRENCH 45 LF a ZO d U O> r W U(AUQ Z w 2z g m m a a O w w � � J F w Z) F w p U U Q ENGINEER.NBMSM DRAWN BY:MSLI_ M SCALE: REVISION: - SHEET OF m MCEP7M�W�T���fl I1KSEptiPnvss SGECiFlV TOX99wLL PEuiN THE PNCpEPM1 OF xp COxxV 6ERNCES INC.90tH PF 0.gPo5EW__ U7NISPECIFICNAInE H�V1 AI�NLWGrou Com n FILE.euEmsNteeeu�ssx.e.g PLAN VIEW A NORTH -t- 224 T MCI PLACE EXISTING(4)2BB CT CORNING GEN FIBER CABLES 111 P 288 FOH -yy,Q Wt W1100'TAILS COUNTv wAsrviRaTOH E CITY: TIGARO % CONST-WIG% rtl Fc-n ao 48 FIBER COREII@ DRILL I Parking Garage SITE NAME K4 (TAILFROM INTO EXISTING f 10300 SW Greenburg Rd CRANMING I LARD HUB) MANHOLE -� PLACE 288 FIBER - PG4848Z539VM (TAIL FROM _ (n 48X4BX38HH NUB) -�� - w MOUNTING PAD '� / a �����/ V Z > O Sir of LLI T —R OPE tl M't Mid N.N M:',.. AND PLACE _.. DM I'.... w (n Z 7 O AND PLACE(1) M=M 4"HDPE®42" - t aM'QII%row— bP 6'� AF M5 M MI 7— u) MATCH TO PROJECT _a iIT „ 7 —4 — m(n a-2 o HE -- — FIB:BUR: 54117308 �_R M g- w o FIB:BUR::54117307 �wAy �. -- k --�------ - b —y -_ �ZOa g m FIB:BUR::54117004 „_ � . m D_ LL FIB:BUR::54117194 M�—M _ SWOa Sr � g o � „ (Asphalt) S Fn F- RPN Varies j ~ „ „ M • aLu O e slaaa, a x a x 0Rii C10mm D/W $ ENGINEER.N9USI/D Location Looking Northwest DRAWN BY NSOLSTPD JSCALE: -. _ REVISION:wa Parkn9 Wt SHEET OF io NEW HUS IM ICTH u- PpMYp Lol eWEMETw Le u r.Po'�c.ICI.oa LJ.1.rose TMN scearc y.11TeR SMIIMLIo%�IIIr�l01a a s' Ia Is' ra UNDERGROUND UTILITIES HAVE SEEN PLOTTED FROM AVAILABLE RAND FIELD cwL se. 1'-2D' OBSERVATIONS BUT ARERE NOT NOT NECESSARILY EXACT. IT IS THE CONTRACTORS nlrM�mrcro mm RESPONSIBILITY TO FIELD LOCATE ALL UNDERGROUND OBSTRUCTIONS AND UTILITIES CA„ WkEyp,M PRIOR TO CONSTRUCTION.COMPLETE REPAIR FILE„weawzxmio-ouessm.a..R zassss OF ANY AND ALL DAMAGES INCURRED SHALL BE /° °9 NOT�REO41� AT THE EXPENSE OF THE CONTRACTOR.