2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 12470 SW 128 Ave
City: Tigard Zip: 97223
Owner's Name: Timothy Allison Date: 04/20/2021
Contractor's Name: ION DEVELOPER LLC CCB #: 230394
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? 0 No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure 0 Yes If"Yes", qualifies for
"C"or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes x❑ Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 ps or less?
structures other than If"Yes", qualifies for
Yes the prescriptive path.
above
n No
1
I:Building/Forms/Photo Voltaic-Checklist02-01-l l.docx
• • • •. •• •• • • • • ••
• . . • • • • • • • • . • .
• • •• •. • • • • •
• •
•.. . • •. . • . .
• • . • ••
• . • • •
. • • • • • • •*
Is the construction
material wood and does Yes
Type of •• eel/ ••• • ;If" •6sllivalifies for
the construction qualify �. • • . ••• •
Construction •• Nd • • • thezres tive path.
as"conventional light • • • ••••
•frame"construction?
Is the spacing 244inais • • • •••
•
ortess?; ••• ..:`(• •
• • • • .
• ••• •• • ,
Pre-engineered trusses. ElYes If"Yes", qualifies for
the prescriptive path.
No
Roof framing
members Is the spacing 24 inches
or less?
NominalIf"Yes", qualifies for
lumber.
❑ Yes the prescriptive path.
❑ No
Is the combined weight ❑X Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance 0 Yes „
with Section 305.4(3) of If Yes , qualifies for
the 2010 Oregon Solar El No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
x❑ of composition
shingle.
Is the roof mounted 0 Yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof ❑ No
to the roof framing or blocking the prescriptive path.
directly?
2
I1Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
• • •• •• •• • • • • •••
• • • • • • • • • • ••• •• • •
• • •• •• • • •• • • •
••• • • •••
• • •• • • • •• • • •
• • • • • • • ••
❑ Yes
Is the gauge 26 or less? • ••• • • •If"Yr4",qualifies for
Po, ; . ••tl4e()resaiiptive path.
• •••
• . • • • •
•.• .•.
115 lbs for 60 inch
spacing or 9s,•1 • • •••
• ••. •I• V."Yes', qualifies for
❑ ; YCS• •• • : the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. '/"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
Ej module to the roof Yes theprescriptive ath.
solar modules p
surface. ❑ No
3
I:Bu ilding/Forms/Photo Voltaic-Checklist02-01-11.docx
•
• • . •• •• • • • • .•
• . • • . • • . • •• • • •
• . . S. • • • • .
••. • •• • • • •
• . ••• • •• • •
• • • • •
•
Submittal Documents required for Prescriptive Installations
Show the location of the PV system 1n:retation tb Duildings,si fc ures,
•property lines, and, as applicable, flood haaard areas,.••
,;; ,
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.• •• • •••
•
Attach a simple structural plan showing the rvo£framing(sager size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SILFAB
Model Number: 340NL
Listing Agency:
4
I:Building(Forms/PhotoVoltaic-Checklist02-01-11.docx