Report P-SERIES Sul`TAL DATA: PKA-Al2HA7 & PUY Al2NKA7(-BS) MITSUBISHI 12,000 BTUIH WALL-MOUNTED AIR-CONDITIONING SYSTEM ELECTRIC Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PKA-Al2HA7 ❑ PUY-Al2NKA7 ❑ PUY-Al2NKA7-BS r r,"* ,is I ,{ vt • INDOOR UNIT FEATURES • Sleek,compact design • Simple installation • Vane setting for air flow direction control • Auto fan speed mode • Ideal for spaces such as server rooms.daycare centers,classrooms,churches,small offices,and more OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • • Power receiver pre-charged with refrigerant volume for piping length up to 100 ft(70 ft.for Al2/18/24/30) • Low ambient cooling down to-40°F providing 100%capacity(only for PUY models with wind baffles installed) • 24-hour continuous operation(cooling mode) • High pressure protection • Fast restarts in cooling mode(15 seconds for 12/18/36/42,50 seconds for 24/30) • Superior energy and operational efficiency 1 Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: PKA-Al2HA7 & PUY-Al2NKA7(-BS) Maximum Capacity BTU/H 12,000 Rated Capacity BTU/H 12,000 Minimum Capacity BTU/H 5,800 Maximum Power Input W 1,000 Cooling1 — ( Rated Power Input W 1,000 Moisture Removal Pints/h 2.0 ) Sensible Heat Factor 0.81 Power Factor % 94.5 SEER 20.8 Efficiency EER1 12.0 Voltage,Phase,Frequency 208/230V, 1-phase,60 Hz I . Guaranteed Voltage Range V AC 198—253 Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) kA 12 Recommended Fuse/Breaker Size(Outdoor) A 15 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 Fan Motor Full Load Amperage A 0.33 Fan Motor Output W 30 Airflow Rate,Dry CFM 320-370-425 Airflow Rate,Wet CFM 290-335-380 External Static Pressure in.WG n/a Sound Pressure Level dB(A) 36-40-43 Drain Pipe Size In.(mm) 5/8(16) Condensate Lift Mechanism,Max.Distance In.(mm) n/a Indoor Unit Heat Exchanger Type Plate fin coil External Finish Color White Munsell 1.0Y 9.2/0.2 W:In.(mm) 35-3/8(898) Unit Dimensions D:In.(mm) 9-13/16(249) H:In.(mm) 11-5/8(295) W:In. 39-6/16 Package Dimensions D:In. 15-12/16 H:In. 13-6/16 Unit Weight Lbs.(kg) 29(13) Package Weight Lbs. 33 Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 90 DB,73 WB/66 DB,59 WB Temperature range MCA A 11 Outdoor Unit MOCP A 28 Fan Motor Full Load Amperage A 0.50 Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: PKA-Al2HA7& PUY-Al2NKA7(-BS) Fan Motor Output W 46 Airflow Rate CFM 1,590 Refrigerant Control Electronic Expansion Valve Heat Exchanger Type Cross fin Sound Pressure Level,Cooling1 dB(A) 44 Compressor Type INVERTER-driven twin rotary Compressor Model SNB092FNCM Compressor Rated Load Amps A 7 • Compressor Locked Rotor Amps A 12 Compressor Oil Type//Charge oz. FV5OS//12 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a W:In.(mm) 31-13/16+7/16(809+62) Unit Dimensions D:In.(mm) 11-3/16(300) H:In.(mm) 24-13/16(630) W:In. 37-1/16 Package Dimensions D:In. 16-3/16 H:In. 27-7/16 Unit Weight Lbs.(kg) 92(41) Package Weight Lbs.(kg) 104(47) Outdoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 115 DB/-40*DB Temperature Range Type R410A Refrigerant Charge Lbs,oz 4 lbs,7 oz Gas Pipe Size O.D.(Flared) In.(mm) 1/2(12.7) Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Piping Maximum Piping Length Ft.(m) 165(50) Maximum Height Difference Ft.(m) 100(30) Maximum Number of Bends 15 Notes AHRI Rated Conditions(Rated data is 1Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB determined at a fixed compressor speed) 'Wind baffles required to operate below 23°F DB in cooling mode.For PUY models,wind baffles can be utilized to extend the cooling operation range to -40F. Please refer to the wind baffle submittals to determine which baffles are required to meet the desired operation range. "System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION • External Outer Panel: Phosphate coating+Acrylic-Enamel coating • Fan Motor Support:Epoxy resin coating(at edge face) • Separator Assembly;Valve Bed: Epoxy resin coating(at edge face) • "Blue Fin"treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. p 7 ACCESSORIES: PKA-AI2HA7 Wireless Remote Receiver ❑PAR-FA32MA-W i Wireless Remote Receiver a PAR-FA32MA-E kumo touchma RedLINKTM Wireless Controller ❑MHK2 { Deluxe MA Remote Controller ❑PAR-40MAAU ] Simple MA Controller o PAC-YT53CRAU-J Touch MA Controller o PAR-CTO1 MAU-SB Wired Remote Sensor ❑PAC-SE41TS-E s Lockdown Bracket for Wireless,Hand-held,Remote Controller o RCMKP1CB 1 Wireless Temperature and Humidity Sensor o PAC-USWHS003-TH-1 Flush Mount Remote Temperature Sensor ❑PAC-USSEN001-FM-1 � Wireless Interface 2 ❑PAC-USWHS002-WF-2 Thermostat Interface ❑PAC-US444CN-1 kumo station® ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01UP-E IT Extender a PAC-WHS011E-E BACnet®and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Connector for CN32(remote on/off) ❑PAC-SE55RA-E External Drain Pump o PAC-KEO7DM-E External Drain Pump ❑PAC-SH75DM-E Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Mini Condensate Pump-230V application o SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor a X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)up to 48,000 BTU/H o X87-721 -208/230V [recommended] MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 Btu/h o X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 Drain Pan Sensor ❑SS610E 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-Black ❑TAZ-MS303 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-White ❑TAZ-MS303W Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: PUY-Al2NKA7(-BS) i .. Air Outlet Guide o PAC-SJ07SG-E '; Front Wind Baffle o WB-PA4 Side Advanced Wind Baffle o WB-SD4 Rear Advanced Wind Baffle a WB-RE4 Drain Socket o PAC-SJO8DS-E E - Centralized Drain Pan ❑PAC-SG63DP-E I M-NET Converter o PAC-SJ19MA-E M-NET Converter ❑PAC-SJ96MA-E Control/Service Tool o PAC-SK52ST Hail Guard a HG-A5 Condensing Unit Mounting Pad 16"x 36"x 3" o ULTRILITE1 E Outdoor Unit Stand-12"High a QSMS1201M 1 Outdoor Unit Stand-18"High o QSMS1801 M 1 Outdoor Unit Stand-24"High o QSMS2401M Heavy Duty Wall Mounting Bracket for Outdoor Units—Coated Steel o QSWB2000M-1 } Heavy Duty Wall Mounting Bracket for Outdoor Units-316 Series Stainless Steel o QSWBSS 1/4"x 1/2"x 15'/1/2"Lineset(Twin-Tube Insulation) a MLS141212T-15 1/4"x 1/2"x 30'/1/2"Lineset(Twin-Tube Insulation) o MLS141212T-30 1/4"x 1/2"x 50'/1/2"Lineset(Twin-Tube Insulation) ❑MLS141212T-50 1/4"x 1/2"x 65'/1/2"Lineset(Twin-Tube Insulation) ❑MLS141212T-65 1/4"x 1/2"x 100'/1/2"Lineset(Twin-Tube Insulation) ❑MLS141212T 100 Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: PKA•Al2HA7 Unit inch(mm) 1,31,6',367 IIIIIII MOM 766 sole iitf - =11=-1 illii���iin�ir1��=I la Ell asaa boo. 23.9/161599, Frhni vat RMh1,.e --mot 11 ) J - C ----.--■l 6 6a....._ . rill c 0 Lenude 5�pie. r_L 688) 6-1/16)155) 9-13116(R59) . 3315(5 \tralMMk t--y [non F3Mtt61YM(891 Knock hut oak Br� rorM NR.9 .N KM Sleeve 19431ee 161 )m nn ay .e _�I 626/233-611R .2-t2�.r1m ( - . 1p616o) (065-00) , + r L. II; 3enrrnl0 lw upxrbUbw� ,j .,.. ►I, '. ilik„ „___..).e.,.ma.,,r...,,,) o�innw./ 17.I6516N52)G..cro. 669116u) , En*. m.Nmn..een 21dn16(5366,0 p 3/1 7e -66(166) \(.054):.4r.) )y16(16Q Unceeauo nab •.Wm Yn. 06FR06)1516am 6,5 _ 25-11,6(612) 1111111.111111111111.11 Flew49Lqu6ppe 11aF(66. I'mormallolallailliallanallanl Mill piping c66�. Ii2F(612.7) a,l holeRan MN Oa(616)0D ie, wm .� �MN Effective Mplk lS.Y.Id00) lower manual r Kneelt eu We Reeves C Ow Poem l0•N B Center measurement Iv*r/32 .5 .05I,6(¢9) a. a ..r. Boll Wok P�—g is la >? ___ nag P—i 6Mnnr�Mo1�5. .,.i.. + dry J 303 G � :d1� Ya 16)) _-���I61_ a=_ ��ee—= i 0 (8.5) 'lint-l:dim pip 3,4(20 �uilp- .€112 mum ryittsj .411P �j .1 �9An61231.5) 6-1B,612G' R ram- vela F$�^ 1 grT. eSe I &k"iaa w t.' CL+ E & .Nby 5 f`, dada ij,p.- Mad ou hole la 97009 MINI► Rewme..n.e.M6ew.4 Irbil �lJ�E1 t Imml +q t.NM )116305)l — 0 31— ! .1.11I16pe3) I a a 16 3.3,7 .!t 1.66.1J1)53150) Be WW1 2 M&SIB M..6)/8050) — r2ID) 6-11/16(h) ■- 1 alin giaal B • i Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. i DIMENSIONS: PUY Al2NKA7(-BS) Unit: mm<in> 404.5<15-15/16> drain hole °0 Air intake a 42 1-U Sha.ed notched holes `' Installation.olt pitch (Foundation Bolt M10<W 3/8>) 500<19- 1/16> .ram ' M o � -- Air intake "' M Air discharge I ,"'�, 40<1-19/321 m 2-10.21 oval hole >' 23.2<15/16> 22.3<29/32> oumahon:o r 0 M Service panel II <W 318') 22<718, Terminal connection for charge plug Left. Power supply wiring ) Right Indoor/Outdoor wiring Handle for movin lll� Vii 1 T� Connection for p IIIIIIIdII�II�IIIII IIIiIIiIIIIIIIIIIIII� , i^�I r liquid pipe FLARE 06.35(1/4Fi I `° 1!,dIIIIIIII911 IIIIIIIIIIIIIIIIILI Earth terminal N IIIIIIIIIIIIIII'IIIII IIIIIIIIi nm(ll I $ Service panel ;.IIIIII IIIIbdIII IIIIb1IIIIIIIIIIIi1 Un wr CO A 0,-, ,..:_• ;____,_ I„, _.... IIIIIIIIIIIIIII'I!II IIIIIIIIIi!IIIIII!il . , . IIIIIIiiIIIliilillllllllllll►!!!;Iiilllll Kg. _ _ 2-022.2<7/8> c i3-L - —r =' 1/2 conduit hole a .,' - °./k Connection for gas pipe FLARE e12.7(12F) 154.5<6-3/32> - Service port 185.5<7-5/16> v 310<12-7/32> o m 809<31-718> 62<2-15/32> Free space around the outdoor unit FOUNDATION BOLTS (basic example) Please secure the unit firmly with 4 foundation(M10<W3/8>)bolts. (Bolts,washers and nut must g 100mm<3-15/16>or more as long as be purchased locally). no obstade is placed on the rear and right-and-left sides Vof the unit <Foundation bolt height> tlllll'liililllhll,,l°'Illill _':_J fiiliIIIIlJIIIflI'lllllll)IIIlh'l Ir ,. r M15nem IIIIII,iliilipy;iloli6!, Min.35nrmm FOUNDATION j Inlllilib;ii kiiii Illi l!liliil IlllliZISIIIIIIIIIilltilllllll g i 1�\ H ram\ PIPING-WIRING DIRECTION C►11/1f> / CM3-i5i10> / ✓ ✓ Piping and wiring connection can be made from the rear direction only. 2 sides should be open in the right,left and rear side. 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com Airs CERTIFIED' caus FORM#PKA-Al2HA7/PUY-Al2NKA7(-BS)-202003 Intertek Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. I