Specifications ' - --~ ~_~ _ ����. ��K �~�� o ~� 9/21/2021 &Ur 9 91 9o4 AM �TY(]F T�GARD BUILDING Structural Engineering Calculations for: Spa Logic Hot Tubs l42865VV Pacific Hwy Tigard, OR Raceway Letters � Index Title 1 Basis for Design Z Wind Loads 3 Faotener[a|cs 4 Section Sketch S Digitally vg,ed by Carl ' Carl Meyers '°*5°=" 09/21/2021 .~ K~° ~' ; 4: . Prepared by: Dave Knight OREGON Reviewed by: Carl Meyers RENEWS: 12/31C2022 YESCO. i 1605 South Gramercy Road Salt Lake City, UT84104 Pkone: OU1.487.8481 9/21/2021 9:34 AM BASIS FOR DESIGN Project: Spa Logic Hot Tubs Descript: Raceway Letters Ref: BUILDING CODE: 2019 OSSC 2019 EDITION OF THE OREGON STRUCTURAL SPECIALTY CODE OSSC LIVE/SNOW LOADS: NA GRAVITY/DEAD LOADS: RACEWAY LETTERS= 5 PSF LATERAL LOAD PARAMETERS: RISK CATEGORY= II Use 2019 OSSC OSSC Wind Speed Map Figure1609A WIND: WIND SPEED,V ult= 97 MPH,3-SECOND GUST WIND EXPOSURE = C WIND LOAD ON SOLID SIGNS ATTACHED TO BUILDINGS Project: Spa Logic Hot Tubs Descript: Raceway Letters Ref: ASCE 7- 16, Section 29.3.2 &Chapter 26 &30 ASCE 7-16,Section 29.3.2 checks: https://hazards.atcouncil.org/ If the sign meets the following criteria then the wind pressure is calculated using Chapter 30,with (Gcp,) equal to 0: -The plane of The sign must be parallel to the plane of The wall. -Any gap between the wall and the sign can be no greater than 3 ft. -Signs can not extend beyond the side or top edges of the wall. -If there is a gap between the sign and wall,the edge of the sign must be at least 3ft from all free edges of the wall. Building,Sign and Terrain Info. Building Mean Roof Height,h= 20.00 ft Length of wall (least horz.dim.)= 64.00 ft Building risk category: II Region of zone 5:a = 6.40 ft Height of Sign Above ground,z= 20.00 ft Basic Wind Speed,V„it= 97 mph (3-second gust) Trib.Wall sign height: 2.64 ft Exposure Category: B Trib.Wall sign length: 30.00 ft Ground Elevation: 276 ft Effective Area: 79.06 f t 2 Sign Located in Zone: 5 ASCE 7-16 Section 26.10.2 Velocity Pressure qh=0.00256 KZ KZt Kd Ke V2(Ib/ftz) (26.10) Velocity pressure coefficient for sign height, KZ= 0.70 (Table 26.10-1) Velocity pressure coefficient for mean roof height, KZ=Kh= 0.70 (Table 26.10-1) Topographic factor, KZt= 1.00 (Sec.26.8.2) Directionality factor, Kd= 0.85 (Table 26.6-1) Ground elevation factor, Ke= 0.99 (Table 26.9-1) Basic wind speed,V= 97 mph (Sec.26.5) qh= 14.2 lb/ft 2 qZ= NA Ib/ft2 ASCE 7-10 Section 30.4.2 Design Wind Pressure(Buildings with h<=60 ft) p=gh[(GCP-(GCP;)] (Ib/ftz) (30.3-1) Where: Mean roof height velocity pressure,q h = 14 Ib/ft^2 (26.10) External,combined gust effect factor&Pressure coefficient,GCP= 0.84 -1.08 (Fig.30.3-1) Internal,combined gust effect factor&Pressure coefficient,GCP;= 0 0 (Sec.29.3.2) p = 11.9 lb/ft2 (Into sign) <16 psf,use 16 psf p = -15.4 lb/ft2 (Away from sign) <-16 psf, use-16 psf 9/21/2021 WALL MOUNTED SIGNS 9:34AM Project: Spa Logic Hot Tubs Descript: Raceway Letters Ref: 2019 OSSC Wind = 97 mph Exposure= B Note Concerning Sign: Raceway Centered Vertically on Letters Type of Sign: Raceway and Letters Height of Raceway and Letters:(H) 2.64 ft Overall Length of Raceway and Letters:(L) 30.00 ft Depth of Raceway and Letters:(t) 9.38 in Area of Raceway and Letters:(A) 59.30 sf,(75%of H*L for Letters) Vert. Dist. between Top and Bottom Fastener Lines(d): 10.00 in Vert. Dist. From Centroid to Furthest Fastener Line(y): 5.00 in Wind Pressure(p): 16.00 psf(From Wind Sheet) 0.6p: 9.60 psf(ASD Load Combination) Wind Force(W): 569.25 lbs Moment From Wind: (Mw) 2846.25 lb-in Pullout at Top Line from Wind: (TW) 284.63 lbs Dead Load: 5.00 psf Dead Force(D): 296.48 lbs Moment from Dead:(MD) 1389.77 lb-in Pullout at Top Line from Dead(TD) 138.98 lbs Total Pullout at Top Line: (T) 423.60 lbs Total Shear at Top Line:(V) 148.24 lbs } � e /- RACEWAY LETTERS �, Wall Type: EIFS or Stucco with Backing Fastener Type: Powers Strap Toggle(1/4") Assumes Composite Wall=50%CMU Values Allowable Shear: 142 lbs per fastener Allowable Tension: 135 lbs per fastener Min.No.of Fasteners Per Line(for Tension) 4 fasteners per Line Min. No.of Fasteners Per Line(for Shear) 3 fasteners per Line Actual Number of Fasteners used per Line 8 Approx. 48 in o.c.(max) - CSR: 0.52 O.K. Use 8 fasteners(min)per line,Top and Bottom 9/21/2021 WALL MOUNTED SIGNS 9:34AM Project: Spa Logic Hot Tubs Descript: Raceway Letters Ref: 2019 OSSC Wind = 97 mph Exposure = B Vi iffit Fit•14.S1(W+til Md IT01 04 tInattC 95+(st184C?,,PlS§a:t4.am, uP xx,n..t.rIfrr,' 1*.r.-1,PRSt C iY T.8418..Intkt4VIfrtf.IIWYMOW t EIFS OR STUCCO WALL W/PLYWOOD BACKING PAIGE WALL BUSTER I' FOR SECONDARY ;t a f' :4, p WIRING IIII��III , ,13*'.!;0 II CONDUIT FOR ------- WIRING • t3 a SILICONE AROUND IIIIIIIIIIII It 1111.111111 II ItsPer, h • CONDUIT w PAN CHANNEL I • F LETTER i 999 RACEWAY 1 e11 1 SILICONE AROUND FASTENER(SHOWN AS FASTENER HOLE REFERENCE ONLY, IN RACEWAY CLIP(TYP.) ACTUAL FASTENER MAY VARY) C) RACEWAY LETTER AT EIFS/ STUCCO WALL• 1 ,SSise..,,1 .11F..ai.tN.........%##T..l...........t.110#.. 1,014 ck:i: ,It#€..-:ktMES.V.T../. ,#1,o5#S tiaMF.ISitliftYY,MI•If#R:444•4i4l4444m1.-141,810 fNb MVil Ibi4O..... • 4