Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
OFFICE COPY RECEIVED NOV 12021 CITY OF TIGARL DING DIVISION' BRIGHTWATER REDHAWK iNaLiDITY OF PERMIT APART 'PHE ISSUANCE OF A PERMIT 16106 SW 108TH 3ASED ON CONSTRUCTION DOCUMENTS AND OTHER TIGARD, OR 97224 DATA SHALL NOT PREVEI IT THE CODE OFFICIAL FROM FEOUIR!NG THE CORRECTION OF ERRORS. OSSC 105.4 FIRE ALARM DATASHEETS Prepared by Fire Systems West, Inc. Phone 360.693.9906 OFFICE COPY CITY OP TIGARDX. RE FOR CODE COMPLIANCE PLEASE PROVIDE Approved: j COMPLETED NFPA 72 OTC: [ RECORD OF Permit#: EPS eQ na. ) - I \-3 q COMPLETION AT Address: {� a Av FINAL INSPECTION Suite#: ry,►T t By: Date: I f- /O -a j .. . .. OS ...71117 t ll p y�1 f l i J ),,t;46'' t ' 1'.36 , }, a 't `B it' 41 j 3444444 1` 3 1, L v E ,7 Gi 06 00l 106th Ave; _ , t "i$s ei C eland o-,i '24 1 .' • ; iia t, i, r �} a tit s '#„ gl a�,t r 4 4t s t d � x l '11 -1t �`o to �_ S l� t oa+ td 1 34Ff,,„,,, ,,,,, iibil �q� i 1 �,..�1r..,4 J', ' '''''' �S ,A- _ • ,..twaters at Re hIll'a`rik v l s 9P,-;i i; iS' ir.at 'l +7+7 q s t t r f ''., te. "�, ` t aI f.3 l tt4,,ifk}{ D4 r�S iF lit ', .�lt{ #�, { ! ..i ( i t t f n • f �. # tt 't tit #i.,;' )4 1 l 4. t a 1, 3 o` ''' n -. ,,lj i lilt!! ,1 if,.t »fi t ry Cod �iaa r - lit' VIt , f tp , 7116 t 4tt i i P 0. s t'. 3 J t ♦ t — $i i Pt i } t . t { r 11 iO. $ , I ii 3 iki, i ,;;ir-i4. t I y .;— ' 1.4j.}g4� b n Y. '� � t>1 t" *t b , l&i i II ;„i i f ar44., {t1� f 3 ) i fi t�— SCOPE OF WORK: Emergency panel replacment of building manual fire alarm. Panel located outside apt 1. Replacing Fire-Lite MS-2 panel with a Kidde FX-5R panel. . 2c5:202/--66 13 y /6,to 4 lee -'ti Small Building Fire Alarm Solutions Kidde • ........, RECEIVED NOV 12021 Technology that saves lives CITY OF TIGARD BUILDING DIVISION Conventional FireSOSO ONO Alarm Systems Via 45 FX-10RD, FX-10R, FX-5RD, FX-5Rum ere rho iwi "'`='` FDNY a, COA 6230 Overview Standard Features Kidde brand conventional fire alarm systems consist of 5 and • Available in 5,and 10 zone(IDC)models 10 zone fire alarm control panels(FACP),an optional integrated • CleanMe®feature provides remote annunciation of a dirty upload/download DACT(dialer),intelligent/analog type detec- detector tor features,serial annunciator modules,and serial remote relay • modules. All FACPs and components are Listed to the 9th edition Automatic drift compensation with select detectors reduces false of the ANSI/UL 864 standard and CSFM/FDNY approved. alarms and extends dust life • Listed to ANSI/UL 864 9th Edition These systems incorporate features designed to simplify installation, • Models with fully integrated upload/download DACT enables operation and maintenance,including front panel programming,one PC programming person walk testing,and selectable IDC and NAC types.In addition, when used with CleanMe®-compatible smoke detectors,these con- • Zone or NAC pairs convertible to single Class A circuits trol panels provide intelligent type features such as remote mainte- • Combination Waterflow and Supervisory IDCs nance alert and automatic drift compensation that significantly reduce • NACs programmable by zone and individually selectable for the chance of a false alarm and simplify maintenance calls. notification appliances,continuous,temporal outputs,or coded Kidde systems are powerful enough to meet the demands of • Front panel programmable simplifies installation and servicing today's life safety installations while leaving plenty of room to grow • Precision synchronization with compatible notification appli- in the future.They support Class A operation by combining pairs of ances and optional audible silence over two wires on-board IDCs or NACs to provide the necessary Class A circuits. For example,the FX-10RD comes factory set to support 10 Class B • On board relays for Alarm,Supervisory and Trouble IDCs and 4 NACs. But it can be field-configured to provide 5 Class • Optional serial bus relay modules are programmable for Corn- A IDCs(no Class B IDC's),and 2 Class A NACs-or any other corn- mon,Zone,or Matrix activation bination of circuits that fall within the circuit-pairing parameters. • Optional serial bus remote annunciator family FX-10RD FX-5RD • One person walk-test(audible or silent) Class B IDCs Up to 10 Up to 5 • Optional City Tie and Reverse Polarity Modules Class A IDCs Up to 5 Up to 2 Class B NACs Up to 4 Up to 2 • Trim ring available for semi-flush mounting Class A NACs Up to 2 1 NAC Power 7.0 amps 3.5 amps Auxiliary power 0.5 amps 0.5 amps Notes:Class A operation will reduce the number of available Class B IDCs and/or NACs, depending on the panel configuration.See Specifications for details. Page 1 of 8 K85005-0126 Issue 1 Power Options Connections Off-premise communication N _— L A fully integrated upload/download dialer is available for reporting Ir— Cabinet f1 events to a monitoring facility.The DACT also supports uploading Main AC 1- / From 120 Vac,15 A,so Hz or downloadingof system configuration,status and event history. wiring block ( O 8 Dedicated branch circuit y g and fuse The DACT is programmable for either single or dual line opera- holder IL II tion. It also supports split and dual reporting for two digital alarm Fuse receivers. Dual transformer r MO'']'IIAC wiring block 1i`'"' The DACT brings additional features to the panel including a `I Nz .� _; 32 character alphanumeric LCD display,local or remote PC pro - .1.0, ii gramming and an event history log. 11�I Remote Annunciators and Relays = The serial bus standard on Kidde conventional control panels is ,o III o ® another installation time-saver.This circuit allows the connection of IA �'M Main Remote System Indicators(FSRSI),Remote Zone Indicators (FSRZI Tie wrap Main controller A,FSRZI-SA)and Remote Relay Modules(FSRRM24)over a four- mounts ;transformer board wire(data and power)circuit.Annunciator and relay modules can be hJ 'IC) 'o 9 T_; installed up to 1,000 feet from the panel on 18-gauge wire. If,, , t Modules are also available for City Tie(CTM)and Reverse Polarity 0 \ (RPM)connections. O'•AilM 1- Mounting studs ,• 0 0 O O' Plug connector Upload/Download DACT/Dialer Remote Relay Module The built-in DACT/Dialer is a multifunc- The Remote Relay Module(FSRRM24) tion module that provides communi- is one feature of the system that sets cations,modem capability,and LCD d - these systems apart from other panels display functions. Its primary function I in their class.This module has five Form ad is as a Digital Alarm Communica !a ( ' C relays rated at 1 amp each.It can be i t ! "' : s tor Transmitter(DACT).As a DACT,it a i configured to function in either a zone `' - transmits event messages to a Digital relay mode or a common system mode. The DACT/Dialer Installs be- Alarm Communicator Receiver(DACR) The Remote Relay Module When configured in the zone relay hind the front panel display. at a monitoring facility.The monitoring mounts on a plastic track 9 facility then notifies the fire department inside an MFC-A cabinet. mode,relays energize when the as- . ""ckn sociated IDC is active.The module can 0,-,, and other responsible parties of the 0 -°' event. Programmable options include be configured for activation by IDCs 1 Line, Woe .. Up to two through 5 or IDCs 6 through 10.One " „Tg split or dual reporting to two DACRs. RRM24s can be fug ra"dia,,,n. mounted in an relay is automatically associated with The DACT module can also be used FSRRM-S71 snap each IDC. track. Up to two `>"• as a modem to connect the panel to FSRRM-S71s can When configured in the common —% both local and remote computers for .- .` be mounted in an 9 uploading and downloading of con �`S^°P, M MFc-A. system mode, relays energize or de-energize when thepanel changes % figuration data(programming),panel g g o . status and event history.For security, a T„ doom state.One relay is available �n the modem can be configured to ac- Comm"";mb°"out-) for each of the following cept programming on incoming calls ""' functions:Alarm,Supervi or it can be required to call a prepro- Power„- sory,Trouble,Power Loss, grammed number before accepting Pnxe,in. Monitor. Eilli downloads and sending uploads. �Wiiw; � The FSRRM24 mounts on a Note:All panel versions The DACT module can be configured mum NB Nc N8 cT6 plastic snap track and can are available with factory to work as all of the above,or as only ,�,,�,�; , GU ,;°, be installed in an MFC-A installed DACT See order �ZZ7 ZZ7 "''' enclosure.The panel will table for orderingi an LCD display or LCD display andI©��� nforms support two RRMs of each modem.odem. Power out configuration for a total of six M"...Ace on the 10-zone panel. Page 3 of s K85005-0126 i, ioF i, i; tiur inurpvs'. Issue 1 Remote Annunciator Specifications General Agency Listings UL864(S3000),ULC,CSFM Remote Annunciators FSRSI Remote System Indicator FSRZI-A/FSRZI-SA Remote Zone Indicator Maximum per System All panels:2 _ 10 zone panel:4 5 zone panel:2 Current Requirements Standby:17 mA Alarm:56 mA Standby:8 mA Alarm 76 mA Voltage Range Minimum:18.8 Vdc;Maximum:27.3 Vdc Maximum Circuit Capacitance 0.03 pF Maximum Circuit Resistance 13 Ohms Wire Size 18-12AWG(0.75mm2-2.5mm2) Mounting ANSI/NEMA OS1-1996 1-3 gang electrical box Operating Environment Temperature:32-120°F(0-49°C);Humidity:93%RH,non-condensing Remote Relay Module-FSRRM24 Configured for Zone Mode Configured for Common Mode _ Maximum per system 10 zone panel:4; 5 zone panel:2 All panels:2 Current Requirements Standby:10 mA; Alarm:70 mA Standby:26 mA; Alarm:70 mA Voltage Range Minimum:18.8 Vdc;Maximum:27.3 Vdc Contact Rating 1 A®30 Vdc Maximum Circuit Capacitance 0.03 pF Maximum Circuit Resistance 13 Ohms Wire Size 18-12 AWG(0.75 mm2-2.5 mm2) Mounting Single FSRRM24 mounts in plastic track(included)or up to two FSRRM24s in an FSRRM-S11 11" track ordered separately.FSRRM24s should be installed in an MFC-A enclosure. Operating Environment Temperature:32-120°F(0-49°C);Humidity:93%RH,non-condensing Dimensions 2-3/4"W x 3-3/8"H x 1-1/2"D(65.9 mm W x 85.7 mm H x 38.1 mm D) F-Series Remote Annunciators FSRA10 FSRA10C Common Controls No Yes Compatibility 10-Zone Panels Only. Dimensions 5-5/8"x 81"x 1 1/2"in(14.3 cm x 21.4 cm x 3.8 cm) Mounting North American 4-inch square electrical box Power Wiring 18 to 12 AWG(0.75 to 2.50 sq mm) Data Wiring 18 to 12 AWG(0.75 to 2.50 sq mm)twisted pair(6 twists per foot minimum) — — — — — —— 18.8 to 27.3 Vdc Operating voltage Supply must be UL/ULC listed for fire protective signaling systems. Do not use FACP accessory power outputs that are interrupted when the panel is reset. _ Standby current 17 mA _Alarm current 98 mA Operating environment Temperature:32 to 120°F(0 to 49°C);Humidity:0 to 93%RH,noncondensing at 90°F(32°C) FSUIM Universal Input Module Mounting _ MFC-A enclosure Wire size 12 to 18 AWG(0.75 to 2.5 sq mm) Operating voltage 21.2 to 27.3 Vdc Circuit capacitance 0.03 pF,max. Circuit resistance 13 ohms,max. Switch inputs Quantity:5 End-of-line resistor:4.7 k ohms 12 W Relay outputs Quantity:9 Type:Common Style:Form C Contact rating 30 Vdc at 1 A(resistive load) Standby Current 53 mA Alarm Current 114 mA Operating environment Temperature:0 to 49°C(32 to 120°F);Humidity:0 to 93%RH,noncondensing at 32°C(90°F) II Page 5 of 8 K85005-0126 Issue 1 Ordering Information Part Description Ship Wt.lb. Number (kg.) • Control Panels Conventional Fire Alarm Control Panel,Red-10 Class B IDCs and 4 Class B NACs,7.0A NAC power,(Pairs of FX-10RD IDCs and NACs convertible to single Class A circuits),upload/download DACT/modem,120VAC power source, 30.5(13.8) 24VDC output Conventional Fire Alarm Control Panel,Red-5 Class B IDCs and 2 Class B NACs,3.5A NAC power,(Pairs of IDCs FX-5RD and NACs convertible to single Class A circuits),upload/download DACT/modem,120VAC power source,24VDC 24.4(11.1) output F-TRIM35R Semi-flush trim ring for FX-5RD 1.7(0.8) F-TRIM1 OR Semi-flush trim ring for FX-10RD 2.2(1.0) Note:remove D"in model number to order panel without the upload/download dialer in the panel Related Items F-XTR120 Expander Transformer,120 Vac-For FX-10 only 4.0(1.8) EOL3.6 1.1 Required UL listed End of Line Resistors-One 3.6K Ohm and one 1.1 K Ohm. 0.1(0.5) One required for each IDC configured as combination waterflow and supervisory. EOL-P1 Required ULC listed End of Line Resistor Plate-includes one 1.1K,3.6K and 4.7K Ohm resistor 1.0(0.5) Off Premises Communications _ F-DACT Upload/dowload digital Communicator/modem/LCD module(Mounts in control panel) 1.0(0.5) CTM City Tie Module(Requires 4"square or 2-gang North American electrical box) 1.0(0.5) RPM Reverse Polarity Module(Requires MFC-A or other listed fire alarm enclosure) 3.0(1.4) Remote Annunciation Remote System Indicator-Includes LEDs for display of Power,Alarm,Supervisory,Trouble and Ground Fault, FSRSI trouble sounder and silence/lamp test switch.Single gang trim plate included,multi-gang plates ordered 0.3(0.1) separately.Mounts in a single or multi-gang North American electrical box. FSRZI A Remote Zone Indicator-Includes red LEDs for five IDCs. Single gang trim plate included,multi-gang plates 0.3(0.1) ordered separately. Mounts in single or multi-gang North American electrical box. Remote Zone Indicator-Includes LEDs for five IDCs. Single gang trim plate included,multi-gang plates ordered FSRZI-SA separately. Mounts in single or multi-gang North American electrical box.Jumper selected Alarm(red)or 0.3(0.1) Supervisory(amber)indications. FSAT1 Annunciator Trim Plate,1 gang 0.1 (0.05) FSAT2 Annunciator Trim Plate,2 gang 0.1(0.05) FSAT3 Annunciator Trim Plate,3 gang 0.1(0.05) FSAT4 Annunciator Trim Plate,4 gang 0.1 (0.05) FSRA10 Single Unit 10 zone remote annunciator for FX-10 K-FSRA10C Single Unit 10 zone remote annunciator for FX-10(with common controls) K-FSUIM Common Function Graphic Driver/Interface-9 relays and 5 switch inputs for common system indicators and Controls Remote Relay Module FSRRM24 Remote Relay Module-Five Form C relays.Configurable for IDCs 1-5,or 6-10,or common system indications or 0.4(0.2) matrix mode.Requires MFC-A or other listed fire alarm enclosure. FSRRM-S11 11"Mounting track.Holds up to two FSRRM24s. 0.4(0.2) Accessories MFC-A Multi-function Cabinet(fire alarm accessory enclosure) 7.0(3.2) Page 7 of 8 K85005-0126 Issue 1 RECEIVED Appendix A:System calculations NOV 1 2021 Battery calculation worksheet CITY OF"WARD BUILDING DIVISION Use this worksheet to determine the minimum size required for the panel's standby batteries. Obtain operating current requirements for initiating devices and notification appliances from their respective installation sheets. Battery calculation worksheet Standby Alarm Current(mA) Current(mA) Base panel[1] /D t•(onA 29-LMA F-DACT1(F)(optional) (65 mA) $ (107 mA) AUX current(see Form A) $ -$- ADC detector current[3] ISMA NAC 1 load 0 .9dao NAC 2 load 0 $ NAC 3 load 0 $- NAC 4 load 0 (3 Total current[6] 19 mA laq*IA Required standby and alarm x 2,) Standby x •063 oRS Alarm time[5] time(in hours) ``(( time[4] (S,w,) mAh + 3g• -12_ mAh = geeN 1 mAh =1000 Battery amp hour total= a,e94 5 t Z Ah x 1.2 Minimum battery size[2] 3,(473 y Ah 62 PIN 3101172-EN•REV 07•ISS 11FEB17