Report
4 FPS20,2(-D0/f2 7sz0 ?ter 0nj)2 6 OFFICE COPY DIVED FMM-1 (A), FMM-101 (A), N OT I F I E R ` b 202� FZM-1 (A) & FDM-1 (A) wl I Y OF TIGARD Monitor Modules with FlashScan® by Honeywell ;UILDING DIVISION Intelligent/Addressable Devices General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors '", ' •. (FZM-1(A)). ,,,, ,......� FMM-1(A) is a standard sized module (typically mounts to a PRMAItt t'` 4" [10.16 cm] square box) that supervises either a Style D 1, ::; (Class A) or Style B (Class B) circuit of dry-contact inputlas,M,," "°- • devices. ..a"' °:A^ W FMM-101(A) is a miniature monitor module a mere 1.3" "." � rw (3.302 cm)H x 2.75"(6.985 cm)W x 0.65"(1.651 cm)D that '". ;gyi supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single gang box behind the device it monitors. 40 FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. FMM-1(A)(Type H) FDM-1(A)is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B(Class open dry-contact alarm activation devices. May also be used B)dry-contact initiating device circuits(IDCs)at two separate, to monitor normally-open supervisory devices with special consecutive addresses in intelligent,two-wire systems. supervisory indication at the control panel. Monitored circuit FlashScan® (U.S. Patent 5,539,389) is a communication may be wired as an NFPA Style B(Class B)or Style D(Class protocol developed by NOTIFIER that greatly increases the A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor speed of communication between analog intelligent devices. (provided) terminates the Style B circuit. No resistor is Intelligent devices communicate in a grouped fashion. If one required for supervision of the Style D circuit. of the devices within the group has new information, the FMM-1(A)OPERATION panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five Each FMM-1(A)uses one of the available module addresses times that of other communication protocols. on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/normal/short) FMM-1(A) Monitor Module of its Initiating Device Circuit(IDC).A flashing LED indicates that the module is in communication with the control panel. • Built-in type identification automatically identifies this The LED latches steady on alarm (subject to current limita- device as a monitor module to the control panel. tions on the loop). • Powered directly by two-wire SLC loop. No additional FMM-1(A)SPECIFICATIONS power required. Nominal operating voltage: 15 to 32 VDC. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. Maximum current draw: 5.0 mA(LED on). • Direct-dial entry of address:01 —159 on FlashScan loops; Average operating current: 375 pA(LED flashing), 1 com- 01 —99 on CLIP loops. munication every 5 seconds,47k EOL. • LED flashes green during normal operation (programma- Maximum IDC wiring resistance: 1500 Ohms. ble option)and latches on steady red to indicate alarm. Maximum IDC Voltage: 11 Volts. The FMM-1(A) Monitor Module is intended for use in intelli- gent,two-wire systems,where the individual address of each EOL resistance:47K Ohms. module is selected using the built-in rotary switches. It pro- Temperature range: 32°F to 120°F(0°C to 49°C). vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit(IDC)for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. supervisory devices.The module has a panel-controlled LED Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x indicator. The FMM-1(A) can be used to replace MMX-1(A) 1,25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x modules in existing systems. 2.125"(5.398 cm)deep box. FMM-1(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations,waterflow devices, or other normally- DN-6720:E•07/30/2015-Page 1 of 4 .. FMM-101(A) Mini Monitor Module Temperature range: 32°F to 120°F(0°C to 49°C). • Built-in type identification automatically identifies this Humidity range: 10%to 93%noncondensing. device as a monitor module to the panel. Dimensions: 1.3"(3.302 cm)high x 2.75"(6.985 cm)wide x • Powered directly by two-wire SLC loop. No additional 0.65"(1.651 cm)deep. power required. Wire length: 6"(15.24 cm)minimum. • High noise(EMF/RFI)immunity. • Tinned,stripped leads for ease of wiring. FZM-1(A) Interface Module • Direct-dial entry of address:01 —159 on FlashScan loops; . Supports compatible two-wire smoke detectors. 01 —99 on CLIP loops. • Supervises IDC wiring and connection of external power source. 3 1415 0 1 ADDRESS 0 1 • High noise(EMF/RFI)immunity. g 13 2 2 12 3 DI 3 • SEMS screws with clamping plates for ease of wiring. 11 �� 4 LOOP4 • • Direct-dial entry entry of address: 01 —159 on FlashScan 10 5 5 loops,01 —99 on CLIP loops. 9 8 7 6 9 8 7 6 • LED flashes during normal operation; this is a program- TENS ONES n mable option. • LED latches steady to indicate alarm on command from control panel. i— Y The FZM-1(A) Interface Module is intended for use in intelli- O W 0'` U gent, addressable systems, where the individual address of --..1-...1 -..1O_ o ;' . each module is selected using built-in rotary switches. This m module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors I I I I being monitored must be UL compatible with the module. The FMM-101(A) Mini Monitor Module can be installed in a The FZM-1(A)can be used to replace MMX-2(A)modules in single-gang junction directly behind the monitored unit. Its existing systems. small size and light weight allow it to be installed without rigid FZM-1(A) APPLICATIONS mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- Use the FZM-1(A) to monitor a zone of two-wire smoke ule is selected using rotary switches. It provides a two-wire detectors. The monitored circuit may be wired as an NFPA initiating device circuit for normally-open-contact fire alarm Style B (Class B) or Style D (Class A) Initiating Device Cir- and security devices. The FMM-101(A) can be used to cuit.A 3.9 K Ohm End-of-Line Resistor(provided)terminates replace MMX-101(A)modules in existing systems. the end of the Style B or D (class B or A)circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- FMM-101(A)APPLICATIONS nals 8 and 9 for Style D application. Use to monitor a single device or a zone of four-wire smoke FZM-1(A)OPERATION detectors, manual fire alarm pull stations,waterflow devices, or other normally-open dry-contact devices. May also be Each FZM-1(A)uses one of the available module addresses used to monitor normally-open supervisory devices with spe- on an SLC loop. It responds to regular polls from the control cial supervisory indication at the control panel. Monitored cir- panel and reports its type and the status(open/normal/short) cuit/device is wired as an NFPA Style B (Class B) Initiating of its Initiating Device Circuit(IDC).A flashing LED indicates Device Circuit. A 47K Ohm End-of-Line Resistor (provided) that the module is in communication with the control panel. terminates the circuit. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-101(A)OPERATION Each FMM-101(A) uses one of the available module FZM-1(A)SPECIFICATIONS addresses on an SLC loop. It responds to regular polls from Nominal operating voltage: 15 to 32 VDC. the control panel and reports its type and the status (open/ Maximum current draw: 5.1 mA(LED on). normal/short)of its Initiating Device Circuit(IDC). Maximum IDC wiring resistance: 25 Ohms. FMM-101(A)SPECIFICATIONS Average operating current: 270 pA, 1 communication and Nominal operating voltage: 15 to 32 VDC. 1 LED flash every 5 seconds,3.9k eol. Average operating current: 350 pA, 1 communication EOL resistance:3.9K Ohms. every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). External supply voltage (between Terminals T10 and T11): Maximum IDC wiring resistance: 1500 Ohms. • DC voltage:24 volts power limited. Maximum IDC Voltage: 11 Volts. • Ripple voltage:0.1 Vrms maximum. Maximum IDC Current:450 pA. • Current:90 mA per module maximum. EOL resistance:47K Ohms. Temperature range: 32°F to 120°F(0°C to 49°C). Page 2 of 4—DN-6720:E•07/30/2015 Humidity range: 10%to 93%noncondensing. Agency Listings and Approvals Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x In some cases, certain modules may not be listed by certain 1.25" (3.175 cm)deep. Mounts to a 4" (10.16 cm)square x approval agencies, or listing may be in process. Consult fac- 2.125"(5.398 cm)deep box. tory for latest listing status. FDM-1(A) Dual Monitor Module • UL:S635. • ULC: S635. The FDM-1(A)Dual Monitor Module is intended for use in intelli- • FM Approved. gent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive • CSFM:7300-0028:0219,7165-0028:0224, addresses.It is capable of monitoring normally open contact fire 7165-0028:0243. alarm and supervisory devices; or either normally open or nor- • MEA:457-99-E. mally closed security devices. The module has a single panel- controlled LED. • U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NOTE: The FDM-1(A)provides two Style B(Class B)IDC circuits NFS2-3030). ONLY. Style D (Class A) IDC circuits are NOT supported in any • Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, application. NFS2-3030). FDM-1(A)SPECIFICATIONS • Fire Dept. of New York: COA #6121 (NFS2-640, NFS- Normal operating voltage range: 15 to 32 VDC. 320), COA#6114(NFS2-3030). Maximum current draw:6.4 mA(LED on). Product Line Information Average operating current: 750 pA(LED flashing). NOTE:"A"suffix indicates ULC-listed model. Maximum IDC wiring resistance: 1,500 Ohms. FMM-1(A): Monitor module. Maximum IDC Voltage: 11 Volts. FMM-101(A): Monitor module, miniature. Maximum IDC Current:240 pA FZM-1(A): Monitor module,two-wire detectors. EOL resistance:47K Ohms. FDM-1(A): Monitor module, dual, two independent Class B Temperature range: 32°to 120°F(0°to 49°C). circuits. 0 93% SMB500: Optional surface-mount backbox. Humidity range: 10%to (non-condensing). NOTE: See installation instructions and refer to the SLC Wiring Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Manual,PN 51253. 1.25" (3.175 cm)deep. Mounts to a 4" (10.16 cm)square x 2.125"(5.398 cm)deep box. FDM-1(A)AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points,starting with the original address. For example, if the FDM-1(A)is set to address"26",then it will automatically assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the FDM-1(A)are 0,2,4,6,or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. ACAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A)modules mount directly to a standard 4"(10.16 cm)square, 2.125"(5.398 cm)deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances,and regulations. DN-6720:E•07/30/2015—Page 3 of 4 FlashScan®and NOTIFIER®are registered trademarks and FireWatchT"is a trademark of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F I E We cannot cover all specific applications or anticipate all requirements. EMIIEHIMi S MNMFiUTIMM& All specifications are subject to change without notice. SYAIITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6720:E•07/30/2015 dn-60383:A2 NC-100R(A) NOTI FI E R° Relay Module for FireWarden Series Panels by Honeywell Addressable General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices,such as fans,dampers,door hold- ers, control equipment, etc. Addressability allows the dry con- .. `� tact to be activated, either manually or through panel . -... programming,on a select basis. so *' Features '" "° ";„ n.a, �•60.,.. """ • Built-in type identification automatically identifies these •*«66«." •Ya it . z s wrkfr�rM* devices to the control panel. • Internal circuitry and relay powered directly by two-wire "" `' SLC loop. « '. r�k • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when • activated. p • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. NC-100R(A) • Direct Decade entry of address: 01 -99 with the FireWar- den-100-2(C)and 01 -50 with the FireWarden-50(C). Applications The NC-100R(A)may be programmed to operate dry contacts Specifications for door holders,Air Handling Unit shutdown,etc.,and to reset Normal operating voltage: 15 to 32 VDC. four-wire smoke detector power. Maximum SLC current draw: 6.5 mA(LED). Construction Average operating current: 230 pA direct poll (CLIP mode), • The face plate is made of off-white heat-resistant plastic. 255 pA group poll with LED flashing. • Controls include two rotary switches for direct-dial entry of EOL resistance: not used. address setting. Temperature range: 32°F to 120°F(0°C to 49°C). • The NC-100R(A) provides two Form-C dry contacts that Humidity range: 10%to 93%non-condensing. switch together. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Operation 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 mm)deep box. Each NC-100R(A)uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its Relay Contact Ratings type and status. The LED blinks with each poll received. On command,it activates its internal relay. Maximum Current Load Description Application Voltage Rating Rotary switches set a unique address for each module. The 9 g address may be set before or after mounting. The built-in Resistive Non-Coded 30 VDC 3.0 A TYPE CODE(not settable)will identify the module to the con- trol panel. Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive(UR=5ms) Coded 30 VDC 0.5 A Inductive(L/R=2ms) Coded 30 VDC 1.0 A Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2•06/17/10—Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UUULC Listed:S635. • CSFM approved:file 7300-0028:230. • FM approved. • MEA approved:file 72-01-E,Vol.2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual,document 52304. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.C E T I F I E D NRIME i MAIUFALi1CNi All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-60383:A2.06/17/10 VESDA-E VEP xtralis® VEP-A00-1P, VEP-AOO-P. VED-A10-P The VESDA-E VEP series of smoke detectors bring the latest l '! r, and most advanced detection technology to provide very early c ' warning and the best nuisance alarm rejection to a wide range of applications. Built on the Flair detection technology and years of application experience,VEP detectors achieve consistent performance over their lifetime via absolute calibration.In addition, the VEP delivers a range of revolutionary features that provide user value. Flair Detection Technology Flair is the revolutionary detection chamber that forms the core of the VESDA-E VEP, providing higher stability and increased longevity. Direct imaging of the sampled particles using a CMOS imager combined with multiple photo- diodes allows better detection and fewer nuisance alarms. Installation, Commissioning and Operation VESDA-E VEP is equipped with a powerful aspirator that enables use of a total of 130m(427ft)of sampling pipe in the one pipe model and 560m(1,837ft)of pipe in the four pipe model.Out of box operation is made possible with AutoConfig which allows airflow normalisation and AutoLearn Smoke and Flow to be initiated from within the detector.VEP is fully supported by the ASPIRE and Xtralis VSC software applications which facilitate ease of pipe network design,system commissioning and maintenance. VESDAnetTM VESDA devices communicate on VESDAnet which provides a robust bi-directional communication network allowing continued redundant operation even during single point wiring failures.VESDAnet enables primary reporting, centralized configuration.control,maintenance and monitoring. Ethernet connectivity VESDA-E detectors offer connectivity to corporate networks via Ethernet,allowing for devices installed with Xtralis monitoring and configuration software to connect to the detector. Backward Compatibility VESDA-E VEP is compatible with existing VESDA installations.The detector occupies the same mounting footprint, pipe,conduit and electrical connector positioning as VESDA VLP.VEP is also compatible with existing VESDAnet installations allowing monitoring of both VESDA-E and legacy detectors via the latest iVESDA application. Features suck • Suitable for Class 1 Division 2 applications-Groups A,B,C&D • Two programmable GPIs(1 monitored)for flexible remote control • One and four pipe models for different applications • Field replaceable sub-assemblies enable faster service and • Flair detection technology delivers reliable very early warning in a maximum uptime wide range of environments with minimal nuisance alarms Listings /Approvals • Multi stage filtration and optical protection with clean air barriers UL ensures lifetime detection performance • ULC • Four alarm levels and a wide sensitivity range deliver optimum • CSFM protection for the widest range of applications • FM • Intuitive LCD icon display provides instant status information for VdS immediate response • NF-SSI(www.marque-nfcom) • Flow fault thresholds per port accommodate varying airflow • VNIIPO conditions • CE • Smart on-board filter retains dust count and remaining filter life ActivFire for predictable maintenance • CCC • Extensive event log(20,000 events)for event analysis and system • EN 54-20.ISO 7240-20 diagnostics Four Pipe VEP • AutoLearn'smoke and flow for reliable and rapid commissioning EN 54-20,ISO 7240-20 • Referencing to accommodate external environmental conditions - Class A(40 holes/Fire 1-0.0280/0obs/m) to minimise nuisance alarms - Class B(80 holes/Fire 1-0.0270/0obs/m) • Backward compatible with VLP and VESDAnet - Class C(100 holes/Fire 1-0.056%obs/m) • Remote monitoring with iVESDA for system review and proactive Classification of any configuration is determined using ASPIRE. maintenance • Ethernet for connectivity with Xtralis software for configuration, Regional approvals listings and regulatory compliance vary between product secondary monitoring and maintenance models.Refer to www.xtralis.com for the latest product approvals matrix. • USB for PC configuration and firmware upgrade using a memory ,..„ VESDA-E VEP so xtraHs TECHNICAL SPECIFICATIONS Specifications 3.5" Display One Pipe VEP Four Pipe VEP Supply Voltage 18-30 VDC(24 V Nominal) el VEP A1°uOAeNini°°'T' Zm Nm fal Power Consumption @ gl VEP-A00-1P VEP-A00-P VEP-A10-P -a" � �'� 24VDC A � 14 Aspirator Setting Fixed 1 5 1 5 ® 4- ISO Power(Quiescent) 8.8 W 7.0 W 8.8 W 8.2 W 10 0 W .✓- „x,MIt Power(In Alarm) 9.6 W 7.8W 9.6W 104W 116W I Dimensions(WHD) 350 mm x 225 mm x 135 mm(13.8 in x 8.9 in x 5.3 in) Weight 4.4 kg(9.7 Ibs) 4.4 kg(9.7 Ibs) 4.5 kg(9.9 Ibs) LED Description Ambient:0°C to 39°C(32°F to 102°F) w Sampled Air-20°C to 60''i,(-4°F to 140°F) a Fire 2 Operating Conditions Tested to-20°C to 55°C(-4°F to 131°F) UL-20°C to 50°C(-4°F to 122°F) di Fire 1 Humidity.5%to 950/0 RH,non-condensing 1,000 m2 A Action Area Coverage 10.760 sq.ft) 2,000 mz(21,520 sq.ft) Q Alert Min.airflow per pipe 15 l/m 0 Disabled Pipe Length(Linear) 100 m(328 ft) 280 m(919 ft) Pipe Length(Branched) 130 m(427 ft) 560 m(1,837 ft) I Fault 1 Pipe 1 Pipe 2 Pipe 3 Pipe 4 Pipe ' Power Pipe lengths depending on number of pipes in use 100 m (328 ft) 110 m 100 m 80 m 70 m • (361 ft) (328 ft) (262 ft) (230 ft) StaX PSU PSU,Auto Pipe Clean Home Page No.of holes(A/B/C) 30/40/45 40/80/100 Icon on Display Description Computer design tool ASPIRE r Smoke and Alarm Threshold Levels Inlet.External diameter 25 mm or 1.05 in(3/4 in IPS) Pipe Exhaust:External diameter 25 mm or 1.05 in(3/4 in IPS)via Q Detector OK adaptor 7 programmable relays(latching or non-latching states) a Detector Fault Relays Contacts rated 2 A i 30 VDC(Resistive) 43 Aspirator Fault IP rating IP40 Cable access 4 x 26 mm(1 02 in)cable entries ti Airflow Fault Cable termination Screw Terminal blocks 0.2-2 5 sq mm(24-14 AWG) Power Fault Dynamic Range 0.0000/0/m to 320/0/m(0.0000%/ft to 10%/ft) Sensitivity Range 0.005to20%obs/m(0.00160/0to6.25%obs/ft) 1. Filter Fault Alert:0.0058/0 to 2.0%obs/m(0.0016%to 0.625%obs/ft) AO Smoke Chamber Fault Threshold settin range Action:0.005%to 2.0%obs/m(0.0016%to 0.625%obs/ft) li g g Frei:0.010%to2.0%obs/m(0.0031%to0.625%obs/ft) Fire2.0.020%to 20.0°Jo obs/m(0.00630/0to 6.250/0obs/ft) ago VESDAnet Fault Event log:Up to 20,000 events StaX Module Fault Smoke level,user actions.alarms and faults with time and Software features date stamp AutoLearn.Detector learns Alarm Thresholds and Flow Fault thresholds by monitoring the environment. Ordering Information Ordering Code Description Spare Parts VEP-A00-1P VE DA-E VEP with LED: 1 p pe.Plastic Enc Wawa VSP-960 VE?DA-E hlcu'ting Bracket VSP-964-03 `CEDA-CE mot e Dctccacm Chamber VEP-A00-P A FA-F\FP with I Ens 4 pip-Plasmic Fri l<, iim -MK3 VEP-AIO-P VESDA-EVEP with 3_E'Die fay.4 pipe -1awic VSP-961 VESDA-E Exhaust adap-i,•U4 VSP-965 \ESDA-E Ea-pfi-e V.id..le Enclosure VSP-962 vF. GA-E Filter VSP-968 \ESDA-E\'EP-AiCO-P IP Font -wer Plastic(LEDs) Approvals Compliance VSP-962-20 VECDA-E Fitter-20 Piece:, VSP-969 A tbUAt\EP-AliI-P Frei il Cuper Plastic(3.5•Display) Please refer to the Product Guide for details regarding compliant design,installation and VSP-963 VE_Ui-L Aspirator VKT-850 A tt-UA-t\tP Urni. Kit __- commissioning. VSP-964 'C FP4A-F`mese r'etei thin(,hnrnhar www.xtralis.com All lechrlcal data s,,direct tillhe f mo of publ ccl.on ono is suL ei.t to changes w thout not cc.All Intellectual Property including but not Gmtted to trademarks,copyrights,patent are hereby acknowledges Doc.No.72063_.l you agree not to copy,comrer,nicate to the publ c,adapt,distr-bole,transfer,sell,modify or publish any kartNv 0U.10)!6-+._n)0 contents of this documentwithocttheexpresspriorwrtttenconsentofXtral',s.Installationinlorrnabon:In September 2020 order to cnsuro hill lit,nct'nnnity,refer to the netcllation r slrnelens as si,ebbed t 01l s • Power Supply VESDA Accessories VPS-100US & VPS-300US The VESDA Power Supply is capable of Features ass.. ,;'k�iarr t providing operating power including battery n, „ • backup for the entire VESDA Laser Smoke Input 120VAC/60Hz • 1.5 ampcontinuous supply current at Detector product line.The VESDA Power PP Y Supply has been designed to power a single 27.6VDC unit to multiple units depending on application ; • Filtered and electronically regulated needs. It provides 24 volt operating power 4 # • output to the VESDA system as well as a battery ', 40 y. • AC fail supervision charger function which supervises and a.Ax ,416,,, • Low AC(brown out)supervision maintains the standby batteries. Consult "Power Supply Capabilities"for details. • Battery supervision • Built-in charger for sealed lead acid Installation or gel-type batteries The VESDA Power Supply models VPS-100US and VPS300US are power-limited • Automatic switch over to standby power supplies.They convert 120VAC/60Hz input into 24 VDC power-limited battery when AC fails outputs.The VPS units are intended for use in applications requiring UL, ULC and • AC input LED indicator CSFM listing for fire protection signalling. The VPS-100US or VPS-300US shall be installed in accordance with the National Electric Code(NFPA 70)and in accordance with any local regulations.See wiring Listings/Approvals diagrams for proper assembly. • UL 1481 listed Fault Reporting • ULC A Power Supply Fault indicator is provided via a dry relay contact(Form C),which • FM (for VPS-100US) changes state due to the following conditions: • CSFM • AC input loss • Low AC input voltage(Brown-out) • Loss of battery voltage • A short circuit of the battery leads • A short circuit of any of the DC power outputs Power Supply Capabilities VESDA VLP or LaserSCANNER* VPS-1000S-XXX provides power for: 1 VESDA VLP or LaserSCANNER,or up to 5 remote(single box)units,or 1 subrack assembly. Battery requirements:(2) 12 volt/12 Amp-hour batteries. VPS-300US-XXX provides power for: up to 3 VESDA VLP or LaserSCANNER detectors,or up to 15 remote(single box)units,or up to 3 subrack assemblies. Battery requirements: • 2 detectors or 2 subracks or 10 remotes require(4)12volt/12 Amp-hour batteries • 3 detectors or 3 subracks or 15 remotes require(6) 12volt/12 Amp-hour batteries VESDA VLC* VPS-100US-XXX provides power for: up to 2 VESDA VLC detectors,or up to 5 remote(single box)units,or 1 subrack assembly. Battery requirements:(2) 12volt/12 Amphour batteries. VPS-300US-XXX provides power for:up to 6 VESDA VLC detectors,or up to 'Must be confirmed with a battery c nd compliant with local fire protection coo desesa and 15 Remote(single box)units,or up to 3 subrack assemblies. Battery requirements: standards. • 4 detectors or 2 subracks or 10 remotes require(4)12volt/12 Amp-hour To facilitate the calculation of the back up battery batteries size,refer to the Battery Calculator(Document 21062),available from Xtralis Partner Extranet • 6 detectors or 3 subracks or 15 remotes require(6) 12volt/12 Amp-hour (www.xtralis.com) batteries VESDA by•>xtralis M11 �,.. Power Supply VE DA essorie vPs-ioous & VPS-3oous VESDA VLF-250* Specifications VPS-100US-XXX provides power for 2 VESDA VLF-250 detectors,or up to Components 5 remote(single box)units,or 1 sub rack assembly. The VPS-100US consists of three main components: Battery requirements:(2)12 volt/12 Amp-hour batteries. the mounting enclosure,the transformer and the main VPS-300US-XXX provides power for 6 VESDA VLF-250 detectors, or up to circuit board.It uses two backup batteries(supplied separately). 15 remote(single box)units,or 3 sub rack assemblies. Battery requirements: The vPs300us consists of one VPS-100US Power • 4 detectors or 2 sub racks or 10 remotes require(4) 12 Volt/12 Amp-hour Supply and one VBC-001 Battery Cabinet.Together batteries the two units can hold up to 6 batteries(supplied • 6 detectors or 3 sub racks or 15 remotes require(6) 12 Volt/ 12 Amp-hour separately). Note:The VESDA Power Supply uses sealed acid, batteries 12VDC,12 Amp/hour batteries.To order,use part VESDA VLF-500* number VBT-012(minimum 2). VPS-100US-XXX provides power for 1 VESDA VLF-500 detector,or up to 5 remote Input (single box)units,or 1 sub rack assembly. 120 vac(+10%/-15%); 60Hz;1.4 amp max. Battery requirements:(2) 12 volt/12 Amp-hour batteries. Output 27.6 VDC(Nominal)1.5 Amps(Max.) VPS-300US-XXX provides power for 3 VESDA VLF-500 detectors,or up to Max.output Current when a single 24 VDC output is 15 remote(single box)units,or 3 sub rack assemblies. Battery requirements: used: • 2 detectors or 2 sub racks or 10 remotes require(4) 12 Volt/ 12 Amp-hour 1.2 amps batteries Max.output when the three 24 VDC outputs are used: 0.500 • 3 detectors or 3 sub racks or 15 remotes require(6) 12 Volt/ 12 Amp-hour mensionAmps per output batteries Dimensions(WHD) 13.9 in.x 9 in.x 4.5 in. Weight d POWER SUPPLY 1 � VPS-100 US 10Ibs.without batteries ^^ VBC-001 61bs.without batteries r l'I M w II Transformertilt Power E .°O OO Operating Temperature limited ou: O 0 �riIIIL� Power supply ambient:32°to 120°F outputs ca3 O az 111 • .. p. ' -I To 120VAC/60HZ Humidity:10-95%RH,non-condensing —� I ar, I Connect to dedicated Humidity 6 • branch circuit for fire I alarm use 10-95%RH,non-condensing Trouble Relay Common trouble relay rated 2A @ 30VDC Qp Battey 0l Battery (Form C:NO/NC) 12 V/12 AH 12 V/12 AH During normal operation,the power supply Fault Reporting Relay is energed. illI® j Cable Access 3/4"knockouts in various positions VPS-100 us Cable Termination Screw terminal blocks 30-12 AWG _►sJ Battery Battery Ordering Information 12V/12 AH 12 V/12 AH �P > P/N Description Requirements CM— VPS-100US-XXX Power Supply Use XXX field to specify input voltage:120 or 220 VAC VPS-3000S-XXX Power Supply Use XXX field BatteryBatt ery Model VPS- to specify input 12 V/12 AH 12 V/12 AH 100US-XXX voltage:120 or and Battery 220 VAC I 13 C=1 Cabinet model VBC-001 vac-oo1 VBT-012 Battery, Minimum of 2 sealed lead required acid,12 VDC, 12 Amp/hr www.xtralis.com UK and Europe+44 1442 242 330 Tdhe Americas+1 800 229 4434 Middle East+962 6 588 5622 Asia+86 21 5240 0077 Australia and New Zealand+61 3 9936 7000 VESDA The contents of this document are provided on an"as is'basis.No representation or warranty(either express or implied)is made as to the completeness, accuracy or reunite n of the contents of this document.The manufacturer reserves the light to change designs or specifications without obligation and without further notice.Except art otherwise provided,all warranties,express or implied,including without limitation any implied warranties of merchantability and fitness for a particular purpose ere sN excluded. Xtralis,the Xtralis logo,The Sooner You Know,VESDA-E,-E,VES ICAM,ECO,OSID,HeiTel,ADPRO,IntrusionTrace,tradeTrace,of XtrTrace, SmokeTrace,XOa,XOh,iTrace,iCommand,iRespond,iCommission,iPIR,and FMST are trademarks and/or registered trademarks of Xtralis and/or its d/or tra ll subsidiaries in the United states and/or other countries.Other brand names mentioned herein are for identification purposes only and may demark and/be trademarks by•x t ra I i s of their respective holder(s).Your use of this document does not constitute or creaie a licence or any other right to use the name an abel. This document is subject to copyright owned by Xtralis.You agree not to copy,communicate to the public,adapt,distribute,transfer,sell,modify or { publish any contents of this document without the express prior written consent of Xtralis. Doc.13988_03 Part 18624