Permit `1 n CITY OF TIGARD MASTER PERMIT
'"! * - COMMUNITY DEVELOPMENT Permit#: MST2021 00395
Date Issued: 10/19/2021
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S103BD07100
Jurisdiction: Tigard
Site address: 12455 SW 115TH AVE
Subdivision: HUNTER'S GLEN Lot: 27
Project: Eide Solar
Project Description: 11.02 kW rooftop solar with 29 panels
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $6,019.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value 0
Bckflw Prevntr: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System N Garage Opener: N All
Roof TopSolar PV System 11.02 kW N
Other Y Other Description: Y Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
EIDE,ERIC&BRITTANY TML INTERNATIONAL LLC Required Items and Reports(Conditions)
12455 SW 115TH AVE 6405 E MILL PLAIN BLVD
TIGARD,OR 97223 VANCOUVER,WA 98661
PHONE: PHONE: 800-364-0470
FAX:
Total Fees: $358.19
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
oc9-nnl-nM(1 rhrni'nil r)AR QS9-nnl-nnQn vnii',Ink/nhfnin a rnn„of the ndoe nr,lirorr ni todinno In ni iMC by rnllinn chin 911 10R7 nr 1 Ann 779 9'Ydd
Issued B Ho-U,y Va.w De Wegi: 0IA/A�Y: Permittee Signature:
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Applicati(; EC IVE a i\ \,3 2-k
Residential �"i !�J FOR OFFICE USE ONLY
City of Tigard SEP 1 3 021 Received q,\(o\Z\ mSC2.OZ1-CO 35 S
Permit No.:
13125 SW Hall Blvd.,Tigard,OR 97231TY OF TIGARD Plan Review A
. o Phone: 503.718.2439 Fax: 503.59 ¢ Date/By:nR /f iv Aik, Other Permit:
T l G A R D Inspection Line: 503.639.4175 I DING DIVISION Date Ready/By: ! ® See Page 2 for
Internet: www.tigard-or.gov No• /Method:+ Supplemental Information
TYPE OF WORK REQUIRED D TA:1-AND 2-FAMILY DWELLING
❑New construction 0 Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement ❑■ Other:Solar equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
Valuation: $6,019.00
❑■ 1-and 2-family dwelling 0 Commercial/industrial
` 0 Accessory building 0 Multi-family Number of bedrooms:
0 Master builder El Other:
Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address:12455 Sw 115th Ave New dwelling area: square feet
City/State/ZIP:Tigard, OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name:Solar Install-EEide Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installation of 29 solar panels in 6 array(s) on a roof mounted 11.02kW PV System Valuation: $
Existing building area: square feet
New building area: square feet
0 PROPERTY OWNER ❑ TENANT Number of stories:
Name:Eric Eide Type of construction:
Address:12455 Sw 115th Ave Occupancy groups:
1 City/State/ZIP:Tigard, OR 97223 Existing:
l Phone:( )(503) 341-3388 Fax:( ) New:
❑ APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES*
(Please refer to fee schedule)
Business name:TML International LLC
Structural plan review fee(or deposit):
Contact name:Maggie Ludden
FLS plan review fee(if applicable):
Address:6405 E Mill Plain Blvd
Total fees due upon application:
City/State/ZIP:Vancouver,WA 98661
Amount received:
Phone:( )(360)836-1729 Fax::( )
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
E-mail:permit@infinityd2d.com
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name:TML International LLC Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:6405 E Mill Plain Blvd Solar Installation Specialty Code checklist.
City/State/ZIP:Vancouver, WA 98661 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( )(800) 818-0598 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.:22360 Total fee due upon application: $201.60
Authorized signature: This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
*Fee methodology set by Tri-County Building Industry
Print name:Maggie Ludden Date:9.13.21 Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Electrical Permit Application COVE FOR OFFICE i SE ONLY ,
City of Tigard Date/B
Permit#:
W13125 SW Hall Blvd.,Tigard,OR 97223 ,,1 Plan Review
s Phone: 503.718.2439 Fax: 503.598.1966j'EP I- zur DateB : Related Permit#:
. Inspection Line: 503.639.4175 [[ �±p p Ready Date/By: Juris: Ed See Page 2 for
T i G A R D Internet: www.tigard-or.gov `�' 01r,1�1r11�r�� Notified/Method: Supplemental Information
TYPE OF •`TCi� ��� DWtS1®� PLAN REVIEW
O New construction ❑ Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked):
O Service or feeder 400 amps or more ❑Building over three stories.
❑Demolition ❑■ Other:Solar where the available fault current ❑Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
Q 1-and 2-family dwelling ❑Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for all other installations. buildings.
❑ Multi-family ❑ Master builder 0 Other: ❑Fire pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#: Job site address:12455 Sw 115th Ave 100HP or more. ❑"A","E","l-2","1-3",
O Six or more residential units. occupancy.
City/State/ZIP:Tigard, OR 97223 0 Health-care facilities. IDRecreational vehicle parks.
❑Hazardous locations. 0 Supply voltage for more than
Suite/bldg./apt.#: Project name:Solar Install-EEide ❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
Description I Qty. I Each I Total
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1
DESCRIPTION OF WORK Limited energy,residential 75.00 2
Installation of 29 solar panels in 6 array(s) on a roof mounted 11.02kW PV System (with above sq.ft.)
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
Renewable Energy ❑ See Page 2
0 PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation
Name:Eric Eide
200 amps or less 100.70 2
Address:12455 Sw 115th Ave 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard, OR 97223 601 amps to 1,000 amps 301.04 2
Phone:( )(503) 341-3388 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:ericeide26@gmail.com relocation
Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 I
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
APPLICANT 0 CONTACT PERSON Branch circuits—new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name:TML International LLC above service or feeder fee, 7.42 2
each branch circuit
Contact name:Maggie Ludden B.Fee for branch circuits without
service or feeder fee,first 56.18 2
Address:6405 E Mill Plain Blvd branch circuit
City/State/ZIP:Vancouver, WA 98661 Each add'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:( )(360)836-1729 Fax: :( ) Each manufactured or modular 67.84 2
dwelling,service and/or feeder
Email:permit@infinityd2d.com Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:TML International LLC Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy ❑ See Page 2 2
Address:6405 E Mill Plain Blvd panel,alteration,or extension.
Each additional inspection over allowable in any of the above
City/State/ZIP:Vancouver, WA 98661 Additional inspection(I hr min) 66.25/hr
Phone:( )(800)818-0598 Fax:( ) Investigation(1 hr min) 90.00/hr
Industrial plant(1 hr min) 78.18/hr
Email:permit@infinityd2d.com inspections for which no fee is
CCB Lie.:223690 Electrical Lie.:C1556 Suprv.Lie.:6210S
specifically listed CYO hr min) 90.00/hr
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required:S cott LeDuc Subtotal:
Print name:Scott LeDuc
Date:9.13.21 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name:Maggie Ludden Date:9.13.21 days after it has been accepted as complete.
* Number of inspections allowed per pennit.
I:\Building\Permits\ELC_PermitApp_ELR_ERE.doe Rev 06/17/2015 440-4615T(11/05/COM/WEB
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Fee for all residential systems combined: $75.00 n Description `e��• I EachI Total
Renewable Renewwable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 01 133.56 2
n A• udio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
n G• arage Door Opener* >100 kva(fee in accordance
with OAR 918-309-0040) 552.26 2
Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is
charged at an hourly(1 hr min) 66.25/hr 1
Inspections for which no fee is 90.00/hr
specifically listed('/hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
$75.00 Subtotal(Enter on Page I):
Fee for each commercial system: Number of inspections allowed per pennil.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
n Audio and Stereo Systems
❑ Boiler Controls
n Clock Systems
❑ Data Telecommunication Installation
fl Fire Alarm Installation
n HVAC
n Instrumentation
❑ Intercom and Paging Systems
n Landscape Irrigation Control*
• Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
n Protective Signaling
n Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
(:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015