Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
• OFFICE COPY iiec2ozi-e9ogi6-' Ws" sw,✓oau sC �--- ECEIVED C rrE tnCT 13 Na1 a r OF TIGARD UILDING DIVISION SUBMITTAL Project NPWM Date Tuesday, August 24, 2021 Table Of Contents Project: NPWM 08/24/2021 Prepared By: HPFC 3 Unit Report 4 Performance Summary 6 System Parameters 6 Electrical Data 6 Acoustic Summary 7 Certified Drawing 8 Unit Feature Sheet 11 Residential Carrier Products Bldr 1.29u Page 2 of 12 HPFC Project: NPWM 08/24/2021 Prepared By: HP FC Submittal Cover Sheet Unit Report Performance Summary Report Acoustic Summary Certified Drawings Feature Sheet Residential Carrier Products Bldr 1.29u Page 3 of 12 11111111112.... Unit Report For HP FC Project: NPWM 08/24/2021 Prepared By: frot ww, Outdoor Unit Parameters Indoor Coil Parameters Unit Model: 25HCE Unit Model. FX4D Unit Size: 2 Tons(Size 24) Unit Size: 24,000 Btuh(Size 025) Voltage: 208/230-1-60 V-Ph-Hz Cabinet Insulation:Single-piece cabinet with 1-in. super thick insulation Voltage: 208-1-60 V-Ph-Hz Refrigerant Type• Puron Heating Size. No Heat Outdoor Unit Dimensions and Weight Indoor Coil Dimensions and Weight Unit Length 25.75 in Unit Length: 22.0625 in Unit Width: 25.75 in Unit Width. 17.625 in Unit Height 35.5 in Unit Height 49.625 in Unit Shipping Weight 175. lb Unit Shipping Weight: 122. lb RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and below. The limited warranty period in years,depending on the part and the claimant,is as shown in the table below. Limited Warranty(Years) Item Original Owner Subsequent Owner Parts 10* (or 5) 5 Compressor 10* (or 5) 5 *If properly registered within 90 days of original installation,otherwise 5 years(except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration).See Warranty Conditions below. OTHER APPLICATIONS The warranty period is five(5)years on the compressor,and one(1)year on all other parts. The warranty is the original owner only and is not available for subsequent owners. Ordering Information Part Number Description Quantity Outdoor Unit 25HCE424AP03 Comfort Series Heat Pump with Puron 2 Tons Cooling 1 14 SEER A ARI Conditions Std Offering (NO High Press Switch) Indoor Coil FX4DNF025L00 FX4D Comfort Series Fan Coil with Puron 24000 BTU Cooling 1 208/230-1-60 Single-piece cabinet with 1-in. super thick insulation Aluminum Accessories KFAHD0101SLP Gasket Kit for Indoor Unit Residential Carrier Products Bldr 1.29u Page 4 of 12 Unit Report For HP FC Project: NPWM 08/24/2021 Prepared By: KFCEH2401C05 5 kW Electric Heater with Circuit Breaker for Indoor Unit The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. i1 ij Residential Carrier Products Bldr 1.29u Page 5 of 12 Performance Summary For HP FC Project: NPWM 08/24/2021 Prepared By: System Performance System: 25HCE/FX4D Actual Clg Airflow: 800.0 CFM System Quantity: 1 Standard Clg Airflow: 800.0 CFM Altitude. 0.0 ft Total Net Clg Capacity. 22.00 MBH Linear Pipe Length' 0.0 ft Net Sensible Clg Capacity' 16.72 MBH COP @ 47 F. 3.84 Htg HP Capacity. 21.80 MBH COP @ 17 F. 2.54 Htg HP Integrated Capacity' 21.80 MBH SEER @ ARI Conditions: 14.0 Heating HP Compressor Power 1.66 kW EER @ ARI Conditions. 11.5 Total System Power 1.91 kW HSPF @ ARI Conditions. 8.2 System Parameters Outdoor Unit Parameters Indoor Coil Parameters Unit Model:_ 25HCE424AP03 Unit Model. FX4DNF025L00 Unit Size(Nominal): 2 Tons(Size 24) Unit Size(Nominal). 24,000 Btuh(Size 025) Voltage: 208/230-1-60 V-Ph-Hz Voltage: 208-1-60 V-Ph-Hz Clg Ent Air DB Ambient 95.0 °F Ent Air DB• 80.00 °F Htg Ent Air DB Ambient 47.0 °F Ent Air WB. 67.00 °F Ent Enthalpy: 31.44 BTU/lb Lvg Air DB: 60.65 °F Lvg Air WB: 58.46 °F Lvg Enthalpy. 25.33 BTU/lb Htg Ent Air DB: 70.0 °F Htg Lvg Air DB: 95.2 °F Heating Size(Nominal). No Heat 1 Total External Static Pressure: 0.50 in wg Electrical Data Outdoor Electrical Data Indoor Electrical Data Unit Voltage: 208/230-1-60 V-Ph-Hz Unit Voltage: 208-1-60 V-Ph-Hz Fan Motor FLA: 0.60 Amps Motor HP: . 1/3 HP MCA: 14.2 Amps Motor FLA. 2.8 Amps Max Fuse:___ 25 Amps Operating Range Min: 197 V Accessory Electric Heater Data Operating Range Max. 253 V EH Part Number KFCEH2401C05 Compressor RLA. 10.9 Amps Electric Heater kW- 5.0 kW Compressor LRA: 62.9 Amps For 2 wire operation (single circuit): Heater Amps: 18.1 Amps Heater Capacity:__ 18.1 MBH Heater+ Motor MCA. 26.0 Amps Heater+ Motor MOCP. 30 Amps Accessory Voltage. 208-1-60 V-Ph-Hz The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29u Page 6 of 12 Acoustic Summary For HP FC Project: NPWM 08/24/2021 Prepared By: Outdoor Unit Parameters: Unit Model: 25HCE Unit Size' 2 Tons(Size 24) Variations' Standard Octave Band Center Frequency, Hz 125 250 500 1k 2k 4k 8k dBA Sound Power,dB 46.0 56.0 59.0 63.0 63.0 60.0 55.0 A-Weighted Sound Power, dBA 76.0 Indoor Coil Parameters: Unit Model. FX4D Unit Size: 24,000 Btuh(Size 025) Cabinet Insulation: Single-piece cabinet with 1-in. super thick insulation Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k Sound Power,dB 66.0 62.0 58.0 55.0 53.0 51.0 47.0 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29u Page 7 of 12 Certified Drawing For HP FC Project: NPWM 08/24/2021 Prepared By: AIR DISCHARGE ( F AIRi INMR /DI SEWAGE I 1 i i' 10;01.1.1":". _ ,I.. - 1 FIELD POWER SUPPLY COIN. . , eT1g IQS2t.21 IOIf IITHII AIR IN-.-.--.. t :� �5�� i�M•+ 1.:i xNacNa17 l gt . y~ AIR Iw F((ED{ 1AS'I022`2I{HOLE �IA 4 ' 1 ' 03,e.,0,.5, I '1 i L(OUID LINE CORN. K _ 3 114" $ fr ( 111 4'� r,=mil--, D 196.01 iBR.91 link iI 0CVAPOR LIRE CONN I-I._Fr Y so t 1 13716'--`. X SO. (46.1) I1' I NOTES. (12.11 G-� - „319'(09.51 TIEDONN IIOCIOJTS (2) PLACES 1.ALLOW 2I'009.6)CLEARANCE TO SERVICE SEE OF UNR,461 112192)ABOVE UNFT. 2 CENTER OF GRAVITY q. 2 13I T i'-- Lk IN 6(162.4)ON ONE SI3E.It(304.6)ON REMAINING G SIDE,AND 26"(6O9,6)SETWEEN I Ti 1I UNITS FOR PROPER AIRFLOW. 3.SERES DESIGNATION tS 1HE 13TH POSITION OF THE UNIT MODELNUMSER Outdoor Model Unit Model: 25HCE Shipping Dimensions and Weights Outdoor Unit Unit Size: 2 Tons(Size 24) Height 40.00 in Voltage: 208/230-1-60 V-Ph-Hz Width 27.88 in SEER_ 14 Length 27.88 in PartNumber: 25HCE424AP03 Operating Weight 144. lb Shipping Weight 175. lb Dimensions A B C D E F G H I J K 25.75 in 35.50 in 0.63 in 4.44 in 21.25 in 9.13 in 1.13 in 3.81 in 27.88 in 27.88 in 40.00 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29u Page 8 of 12 Certified Drawing For HP FC Project: NPWM 08/24/2021 Prepared By: UNIT CONNECTION SIZES NOTE: NOTE: ALLOW 21• FRON FRONT SUCTION' 018 6 074- S/B• I , SWEAT FOR SERVICE AUG 6 036- 3A• I.D. SWEAT 1. SERIES DESIGNATION IS THE LATH POSITION OF UNIT PRODUCT NUMBER 047 TNRU 060 - 7/8"I.D. SWEAT LSQUID: 3!B• I D. SWEAT 2. ALL DIMENSIONS ARE IN PINCUS. UNLESS NOTED CONDENSATE. 314• FP71-1.___� 22 1/16• _ - 10 3r16" - 1 1• ---/r8• B . 2 Ile"— —�" in OUTLET AIR 3/4" 15/16" C '1 - 2•BDIA1 A/32•S • � ,ISCONNICT 04 FPOR NIGH R WIRING I - V " CIRCUIT BREAKERIII I.a LOCATION 7IB"CIA, K.O. ill -.1101 1 T/8" FOR LOW VOLTAGE LTERNATE I, CONTROL MIRING Ttb'.f 3/32".2'OIA. A-O.'S NOTE MODULAR LOKER, CONTROL. ��3 r, FOR HIGH VOLTAGE I UNITS KILL HAVE A ELECTRIC HEATER _ ALTERNATE POWER WIRING 7 r8�DIA. A.O. OPPOSITE SIDE A TWO-PIECE ACCESS PANELIIMI CABINET 1 f5l16• 1' FOR LOW VOLTAGE I 3r8• CONTROL WIRING TOP VIEW OPTIONAL FIELD CONVERTED I RIGHT SIOE RETURN OPENING INLET AIR 1 (SLOPE COIL UNITS ONLY) PAOIL NEL ACCESS A — 1 1 t/a• A 11(IN" y ...4n111111.111111111111111 ... .t-- _ I a SiS. y1 1 E " ITTING IOUCD LINE CONNECTION INNER LINE ' • I LINE • — PANEL . CONNECTION CORRECTION ] IWO 11111SUCTION LINE CONNECTION 11111 - • I �.,r- - 1 $/16" NCR H • �.: C'i l 16' NDDUL FO FOR UNITS IA 7/16" 0 `y+D 10 3/N" SUCTION LINE l CONNECTION S• PANEL FILTER ACCESS OPENI111A•'� I- IV 1 3/16" I -2 1/a" OPENING I SLOPE COIL DETAILS SLOPE COILS RIGHT SIDE VIEW t' I D y CONNECTION LOCATIONS SHOWN ACCESS PANFL tONFTG FOR FOR UPELOW OR HORII. DOWNFLOW OR HORI2. INLET AIR LEFT APPLICATIONS RIGHT AP DICATIONS INLET AIR " COILS FRONT VIEW DONNFLOW APPLICATIONS SHOWN WITH "A• COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR HORIS APPLICATIONS Indoor Coil Unit Model: FX4D Dimensions and Weights Indoor Coil Unit Size: 24,000 Btuh(Size 025) Height 49.63 in Voltage- 208-1-60 V-Ph-Hz Width 17.63 in Cabinet Insulation:Single-piece cabinet with 1-in.super thick insulation Length 22.06 in PartNumber: FX4DNF025L00 Shipping Weight 122. lb Dimensions A B C D E F _ G H J 49.63 in 17.63 in 15.75 in 15.63 in 15.38 in 23.13 in 23.63 in -- 17.00 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29u Page 9 of 12 Certified Drawing For HP FC Project: NPWM 08/24/2021 Prepared By: NOTES. SLOPE COIL I. CONDENSATE PAN DRAIN CAPS NOT SHORN FOR CLARITY 2 ALL DIMENSIONS ARE IN 'INCHES"UNLESS NOTED. T,li'T.P. AIRFLON :2 PLACES). AMU, 2 3t16"TIP. i l i2 PLACES). - I i © L .TIP. PRIMARY DRAT' 12 PLACES)+ 3 Its' SECONDARY DRAT ril F r 1 II G PRIMARY DRAI I Its' ;:MYY DRAT PRIMARY DRAT 113,1i1 .2..SECONDARY DRAI TIP.. SECONDARY DRAI IT(\ l t AAINARt DRAIIUs' �JII ��� 12 i18" 1 5/rOr �5ni" ! t,. ) „i.., i I .. =_ram•• 112' ! 1 Its" [2!9116" 12 PLAC$1► (II illi lPLACESP► 2 It8' I Us" TYP2' 1t8' TIP.+ 1518' " ,!' 11311i' TYP.t 2 3116 3 I TI►.► F 118" 2 ue' TTP, DOWNFLOW TrP' HORI1. LEFT 5' t2 PLACES). UPFIOW (FIELD CONVERTED) NORIL. RIGHT (AS SNIPPED) (AS SHIPPED) (FIELD CONVERTED) Indoor Coil Unit Model. FX4D Unit Size. 24,000 Btuh(Size 025) Voltage. 208-1-60 V-Ph-Hz PartNumber FX4DNF025L00 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29u Page 10 of 12 i 25HCE4 ComfartT 14 Heat Pump (barrier with Puron® Refrigerant 1-112 To 5 Nominal Tons turn to the experts Product Data r. 1 Industry leading Features /Benefits ,` .�. _ Efficiency `*° 14 SEER 11.0-11-5 EER r 8.2 HSPF ® • i • Microtube Technology refngeration system • Indoor air quality accessories available ISound - • Sound level as low as 69 dBA • Sound levels as tote as 68 dBA with accessory sound blanket r _ Comfort • System supports programmable or standard thermostat controls 1, Reliability _ _. • I'oa-ozoire depleting Pusanl refrigerant .q • Scroll compressor • Interval pressure relief valve - o • Internal themial overload • Loss of charge switch ()Info rt • Filter drier t C t�l� I E S ` Raced refrigeration system for maximum reliability SERIES Durability Carrier heat pumps with Putout refrigerant provide a collection of �[�eatherArmarni protection pacl:age: features unmatched by any other family of equipment-The 25HCE4 has • Solid.durable sheet metal construction been designed utilizing Carrier's non-ozone depleub Puronrrefngerant. • Dense wire coil guuard NOTE:Ratings contained in this document are subject to change at any Baked-on pawder paint time. Always refer to the HRI directory(wzv-watrndirectory.org)for Applications the most up-to-date ratings information_ • Long-line-up to 250 feet(76.20 m)total equivalent length u4 to 200 feet(60-96 m)condenser above evaporator.or up to 80 ft.(24.38 m) evaporator above condenser (See Longline Guide for mare information.) • Low ambient(down to-20°Ff-28.9°C)with accessory Int k Residential Carrier Products Bldr 1.29u Page 11 of 12 W W FX4D Comfort Series Fan Coil Sizes 019 thru 061 ; Crier turn to the experts Product Data AIR HAND!.ER TECHNOLOGY AT ITS FINEST ,„ tt1 ��'a.;�3Y`� �.�",': f �<: � r" €" The FX4D fan coils combine the proven technology of Carrier fan coil units with Purong, the environmentally sound refrigerant. These fan coils are loaded with popular features.Factory-installed. Ff, 4 refrigerant-specific thermostatic expansion valves {Tss'V) are ¥ standard with these fan coil designs_The designs feature contoured , + a condensate pans with tugged,drain connections,ensuring that little water is left in the unit at the end of the cooling duty cycle.The lack of standing condensate and corrosion free pans improves IAQ bt } and product life,features homeowners appreciate_ Standard features include grooved tubing and louvered aluminum fins.The large face areas of the refrigerant coils provide superior t y , efficiency for high SEER and HSFF performance. Coil circuiting t � r has also been updated to make the most of all Carrier heat pumps Itt b and air conditioners.Also units come with solid state fan controls, ;tf ,t � t,, .,�,,, 1-in (25mmj thick insulation with R-value of 42. multi-speed motors,and fully-wettable coils_Units can accommodate factory- andior field-installed heaters from 3 to 30 kW. The FX4D tan coil is the?wont'refrigeration design loaded with popular features. It comes in a pre-painted (taupe metallic) galvani7ed steel casing and is shipped with a cleanable,permanent framed filter,and a factory-supplied power plug. These fan coils utilize the latest in electronic commutation motor (ECMt technology through the use of high efficiency, multi-tap ECM motors. In order to meet the California Title 24 requirement of 1.44% air leakage at 0.5' water. an accessory kit is available. (Refer to t. Accessories section.) A1000B Residential Carrier Products Bldr 1.29u Page 12 of 12