Loading...
Report (3) 4C20 se:Z7 C?? // 7?9 6? •11-7 rseresc , rj,eh°mIcilf*" SUBMITTAL 17751.10 E VFD AUG 1 3 2019 CITY OF TIGARD 31JILDING 011SISION crb 2- OFFICE COPY OFFICE COPY OFFICE COpy . , Fl) U vintarrit* I ,eh seresco i Advanced Dehumidifiers i WebSentry+Technology SUBMITTAL 17751.10 . ... 0, =r--,,,, L.,....,e Project Name: Hampton Inn - Tigard AUG 1 3 2019 Prepared For: Doug Giese CITY OF fiCiARD BtilLDING DIVISION Applied Systems Northwest ' ' '' Seresco Model #: NE-004-PS-I-G3NH1202E5E2ANO OAFC Model #: NG-V-01-EUC-V 4.'4 '''',46414,f)e, , '..• .. . - # .."'Pe4,..g.,...,', tr,,, .,",*- 1 ,,,.1..=''.'•''',,,„'..,.' ' '' , f , 4 seresco WortSttntry' . ,;.,,, ,,,:•;::, .. ' , , , , ' '' ' 1 •;*,,,,,,;,r:'.Noit),,,,-'''''''''''41°- 't'''''';',"?..M''. i'.'..."''''... ',,,,, 40, /. ,:,,/,''.., ' :,.., >,', ,;.',:,,:4-,,v, " .. ,. ' ,.., . *I . .33; . .3 .3 ' ' 'i :' 1 —','":344:Lr 341'''' ' ''''' al . , t'l 1 ,, *1 i 4 *-, ...,-.,`"r,:=, .,,t'"•.,,. . v i < . , , < . , ,.. +, 'Va ,p https://serescodehurnidifiers.corn ,„„. ' 1 .,, 1071 Ages Dr , , _ ..,„ • Ottawa, Ontario K1G 6L3 , . 1-770-457-3392 A , _ ,, ..... , . . . - , ... August 2, 2019 seresco s wldYa,nec y oe,„::CAIflEtS webS�nAry*Tcchno�ogy Table of Contents Unit Summary 3 Design and Unit Performance 4 Fluid Cooler Dimension Drawing 6 Features Summary 7 Field Wiring Diagram 10 Pool Water Piping 11 General Specification 12 Warranty 21 Submittal 17751.10 Aug 2.2010 Page 2 of 22 J / e 4 Advanced Nthutnidifiecs webSenrry.,Technology Unit Summary Hampton Inn - Tigard N E-004-PS-I-G 3N H 1202 E5 E2AN0 Model 4 Ton compressor dehumidifier Unit Subseries Pool Water Heater Unit Location Indoor Cabinet NE(compact)Next Generation R3 Expansion Module No Supply Voltage 460V-480V/3PH Unit Control CommandCenter Refrigerant R410A Disconnect No Disconnect Main Blower Discharge 1.0 inch Outdoor Air OA Inlet Motorized Damper&Filter Exhaust Fan None Space Heating Unit mounted electric heater-Single point power connection Heat Control Modulating-factory wired electric heating control Air Conditioning Glycol Cooled A/C by a Fluid Cooler OAFC Voltage 460V-480V/3PH Warranty Standard-2 years on driveline,2 years on compressor,2 years on coils Supply Air CFM 2050 Outdoor Air CFM 460 Supply Air Orientation Horizontal(Supply End) Outdoor Air Orientation Left Pool Water Connection Side Condensate Drain Bottom Heating Capacity 15.0 kW Submittal 17751.10 Aug 2,2019 Page 3 of 22 . , 4r- , Advanced Dehumidifiers seresco i websentry.Technology Design and Unit Performance Hampton Inn - Tigard NE-004-PS-I-G3NH1202E5E2ANO Design Data Reheat Coil Outdoor Air(CFM) 460 Total Heat Rejection(MBH) 67.5 Room Conditions(°FDB/%RH) 83/60 Unit Total Airflow(CFM) 2050 Pool Heating Type Cupro-nickel Co-axial Electrical Data Capacity(MBH) 36 Unit Voltage(V/Ph/Hz) 460V-480V/3PH/60 Water Flow Rate(GPM) 7 Unit Full Load Amps-FLA(A). . . . . . . . . . . , . . . . . . 30.7 Water Pressure Drop(PSI) 3 Unit MCA(A)(min circuit ampacity) 38 Connection Size(in) 3/4 Unit MOP(A)(max overcurrent protect) 40 Connection Type FTP Connection Stub Material PVC Supply Air Blower Maximum Circuit Pressure Rating(PSI) 60.0 Airflow(CFM) 2050 Type Plenum Auxiliary Heat Unit ESP(in WC) 1 0 Location Unit Mounted Number of Motors 1 Type Electric Heater Motor HP 2.4 Capacity(kW) 15 0 Motor FLA(A) 2 3 FLA(A) 18.8 Motor Drive Direct Drive, Control Modulated Compressor Fluid Cooled A/C Type Scroll Fluid Flow Rate(GPM) 25.0 Number of compressors 1 Fluid Pressure Drop(PSI) 3 4 Refrigerant R410A Connection Size,in/out(in ID) 3/4 Motor RLA/LRA(A) 9 6/62.0 Connection Type Stub Recom'd Field Line Size(in,ID),Option A 1-1/4 Evaporator Coil Max Total Equivalent Length(ft),Option A 600 Total Cooling Capacity(MBH) 54 0 Recom'd Field Line Size(in,ID),Option B 1-1/2 Sensible Capacity(MBH) 27 7 Max Total Equivalent Length(ft),Option B 1300 Max AC Sensible Capacity(MBH) 32 8 Max AC Total Capacity(MBH) 50.4 Latent Capacity(Lbs/h) 24.4 Circuits 1 Submittal 17751 10 Aug 2,2019 Page 4 of 22 Jer1 es4W ' Athaeieu�,D1r lifers v��rse,z retn�olvv Design and Unit Performance Remote Outdoor Air Fluid Cooler Model NG-V-01 Design Air On Temp(°F) 100 F Capcity(MBH) 67.5 Connection Size,in/out(in OD) 1-1/4 Connection Type Flange Number of Pumps 1 Pump Motor HP 0 75 Pump Motor FLA(A) 1.8 Voltage(V/Ph/Hz) 460V-480V/3PH/60 Number of Motors 1 Motor HP 1.5 Motor FLA(A) 1 8 MCA(A) 5 MOP(A) 15 Submittal 17751 10 Aug 2,2019 Page 5 of 22 4 I 3 + 2 I 1 ��11 CAD FILE f P-0-0-0-SREO yyyrrr,�n�, �w NFSLOS F7HC0-FBHHr-FbLD s e r S C O DATE -- REV g [279] �^ z01s-oa-3o DRAWN BY SHEET [204] 11/4E.Hatin loft [30] d ll (im.----min _ �DESCRIPTIOND Cab SL D *Refer To Unit Summary Sheet For Options Selected. Unit Operating Weight 870 Lbs. 36% [918] I— y }6t/z _ 63/a } [163] 2 �-5 �] [171] [97] 1 2874 8/8 9 [128] c [28] [224] ._�3%2 c o� i�0 [93] 1 '10. _m t . __ lir 4 n 27 N + 19} [686] o �552] O/A [552] 314 R/A = 10 __ [796] N- ,[250] 0 } If 11 0J 1__� y� I 3% 5 51/a 93A 7 [132] [132] 7 [246] [177] [81] Removable Legs B [177] S/A 30"Required For Service B j All Around Unit 5 Drain pipe Connection red j/i:A�l///// /�/// [125] P-Trap Required) l jir . O o, O/A �l��c� 81/2 - O / c - .. - [220] • • O b 0 e A qk 9... 0 . 4 561/4 2 %� � / .� A [102] [1426] [51] R/A 4 I 3 11 2 I 1 4 1 3 s_.... d} z , 1 9,,,,;0- /IMAM i/�/''M� (/"�(�"�J CAD FILE N$LDS F3HQp F8HHT FO DP-0-0 -5RW s e! 'V c Y 9A4E - REV 2016.11A-30 IoRAwN By E.Hatln SHE'T 2 of 2 D Cab SI, D 3" b { --4,;',',,, 1., Pool Water �"' Connections c ��i �. ,. I ," —Water Cooled A/C ( rig AConnections i c r Cooled A/C *OA Damper Connections . '" Water Coiled A/C connections R/A \Return Air Air Cooled A/C connections 410 Pool Water Connections $ \--Removable Legs B omI . ' T . e3 ',,,, Electric Heater Drain Pipe Connection 1 e iA (P-Trap Required) A S/A 0/A 4 I 3 ,Ip 2 1 1 rn°ric Noise level at 30'(may vary due to installation): / NG V-01 CW Pump Kit rev02 Low speed,40 dBA '.if °�, ". 01/04/19 High speed,50 dBA AIR':,:..., Of' dslater 1 OF 1 orscnivrw NG-V VERTICAL AIR FLOW,PUMP KIT 46— „I -- Airflow clearance a can be reduced to 6" ,��A, on this side only y liel!/rtr6A\V \1 47112 �����r�\U���=J'�,u/,1 45 t • • Q µ 1 _ 11 •,0 Outlet 1 114"Flange ;� ,�'F 96"of clearance required. --I ' , Non-Fused Discmnect(Optional) `- Inlet 1 1/4"Flange 631/2 .11. Pump and ElecNical Panel �' 41 Important note: c, Q� q� ;hL," 27 Minimum 36"of clearance all the l �`'+�` way around for proper air flow. —__________ • _ ( J _.� 8 UNIT OPERATING WEIGHT:450 LBS i secs AeEvaratad[7ehumEdifuers *j � try*Technology Features Summary WEBSENTRY®TECHNOLOGY—REMOTE INTERNET CONTROL, DIAGNOSTICS AND REPORTING There's only one way we could provide superb,factory-engineered performance after a dehumidifier leaves our plant. It's called WebSentry Technology. WebSentry Technology provides a powerful array of capabilities designed to ensure peak operating performance,a minimum of down time and the absolute lowest cost of ownership in the industry. Like an umbilical cord back to the factory,with WebSentry, literally every aspect of the dehumidifier's performance can be monitored, recorded, analyzed and tweaked for its entire V1 t, :. a ' s 1 +:4;; ,... 3 iir�,�'I4, �R,,{d lifetime. Our recording servers are r equipped with sophisticated monitoring ��� � , .d •, � :, . 443efeSto websentry algorithms designed to detect and ,� � � _� protect each and every dehumidifier with literally minute by minute monitoring, 24 hours a day 7 days a week. From regular service issues to1 -- potentially serious matters, if any kind trouble indicator is identified, instant alerts are sent to predetermined contacts including designated service • i technicians via email alerts. Upon notification, authorized service technicians can instantly login to the system live, to observe,adjust and control important parameters via WebSentry's web or smart phone interface. WebSentry brilliantly solves the most challenging issues of dehumidifier industry to guarantee your client has the very best dehumidifier performance,with fewer service calls and minimum down time while enjoying the best lifetime service and value of any dehumidifier in the industry. r€F°< WebSentry®Advantages •: s rest nr rs ,g • Premium extended 1st year warranty—parts and labor ►*"�4' • Fully monitored remote factory start-up capability 44:6* 04rxt f* • Comprehensive installing contractor support • WebSentry smart phone interface $2;„ 4B : .400040,44,6000 WebSentry®Capabilities r` 'geetrif • Remote monitoring for lifetime of dehumidifier • Real time monitoring and alarm service *' o' "°" • Secure online access to real time data 4 • Secure remote access for set point adjustments • Remote access with smart phone application Web Submittal 17751.10 Aug 2,2019 Page 7 of 22 SereSCO Advbas,:dt}ehurzfoizs 1, 1�! w� s•�:�yTscr,�orA9 Features Summary COMMANDCENTER® CONTROLLER—FOR PEAK PERFORMANCE Seresco's CommandCenter Controller,provides unmatched space control,operating efficiency and equipment protection. CommandCenter®Capabilities • Automated,programmable, remote controllable system control • Utilizes built-in pressure transducers • Measures, monitors and controls hundreds of operating parameters • Real time clock with battery back-up and on-board memory for data logging • Easy to use programming interface with alternate web and smart phone control capability • Optional remote operator panel unit can be located up to 1,000 ft.away from unit • Allows live 24-7 monitoring, performance logging,computer analysis,and secure remote control via the Internet or smart phone with Seresco's WebSentry Technology CommandCenter®Specifications • Both staged and modulated control for space heating,cooling and dehumidification. • 20 unit mounted sensors including space/pool conditions and refrigerant pressures. • 16 digital inputs(dry contacts)used for monitoring fault conditions and external control of the unit • 24 digital outputs and 4 analog outputs used for controlling internal and external components. • 2 RS-485 serial ports and 1 RS-232 serial port • 1 Ethernet port(RJ45) • LON, Modbus, BACnet building automation option available. Sensor Information • Refrigerant high pressure • Refrigerant suction pressure • Outside air temperature • Outside air humidity • Air temperature leaving the evaporator • Supply air temperature • Compressor superheat temperature • Compressor compartment temperature Service Technician Mode • History log of sensor data with date/time • History log of alarms and status • History log of operation • Force modes of operation • Adjust damper • Calibrate damper • Test Internal and External Contacts Submittal 17751.10 Aug 2,2019 Page 8 of 22 Seresco r Advaated pchumidtficr* ` WebSsntryr'Techn°���'� Features Summary Alarms • Communication fault, Sensor fault, Dirty filter, High refrigerant pressure fault, Low refrigerant pressure fault, No airflow, Blower overload, Firestat, High supply air temperature INDUSTRY LEADING FEATURES Seresco dehumidifiers match or exceed the specifications of every other competitor in the marketplace. Seresco Exclusive Features Built-in Refrigerant Pressure Transducers • Allow 24-7 Monitoring of critical suction and discharge pressures to ensure optimal system performance Superior Compressor Protection • Advanced monitoring and control technologies to protect compressors including sight glasses on receivers Fully Dipped Coils • Provide 100%protection against corrosion (not just the fins) Direct Driven, Backward Inclined Airfoil Plenum Fans • Provide powerful,quiet,efficient, reliable performance with no belts to adjust,wear out or replace • These fans also allow factory installed auxiliary air heating while providing maximum flexibility for supply air duct options Service Vestibule Outside Air Stream • Protects critical components from chlorinated air stream,maximizes AC efficiency,and allows unit servicing while in operation Ultra Compact Designs • allow twice the capacity in half the footprint(200 Series)with up to 14 tons of dehumidification fitting through a 30 inch door Submittal 17751.10 Aug 2,2019 Page 9 of 22