Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
2:52A-Oooss ., 12zcoax)Goan-i-,R ` RECEIVE® li MAY It ?O21 ''�►' . ., r ' V ►"gk' i CITY OF TIGARD FIRE BUILDING DIVISION • 670 S. 28TH STREET • WASHOUGAL, WA 98671 PHONE (360) 953-8432 • FAX (360) 953-B394 • EXPRESSFIRESYSTEM'S.COM WA LICENSE: EXPREFSB95NF • CCB# 193272 F FIRE ALARM AND SPRINKLER INSTALLATION, INSPECTION, TESTING AND MAINTENANCE ALARM MAAIAOER: DEREK ANDERSON • CELL (36D) 553-962B EMAIL DEREK@EXPRESSFIRESYSTEMS.COM i 1 I i I FIRE ALARM SUBMITTAL Broadway Rose Theater • 12850 SW Grant Ave Tigard, OR 97223 - Th., SYSTEM.. SENSOR® $ 1/1�11 I 1 111111I • F . . . . 1 F Indoor Selectable- Output Horns, E pas 0.164 E Strobes, and r Horn Strobes for Wall Applications 1 System Sensor L-Series audible visible notification „ products are rich with features guaranteed to cut ,�,,1 +., ,,. ,�,,-'r 1 installation times and maximize profits with lower f � • current draw and modern aesthetics. - Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red i plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela 1 • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs with minimal intrusion into the back box,making installations fast 4 • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction t • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. i Agency Listings SIGNALING 0 444:)° ac• �v LISTED APPROVED I 1 S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 AVDS865-05•272272018•Page 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4t1/18 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts • FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1KTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVD5865-05•2/22/2018•Page 3 L-Series Dimensions 1.91' 3.46' a— 3.46'--.. 48.5 mm 88 mm ^ —3.57'— t65' 88 mmPill 1.25' 32 32 mm mm (9.1 cm) (8.9 cm) TTI 1,l 1�11 �f. o 5.27' ds dd•y4 .:: ' 5.38' C C 133.9 mm jiI1 (197=J n I ,11 �, `.� A0548-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL —a— a.7o^ —mm (11.94 cm) 1.91" _ (4.85 cm) 119 mm 125" -m— 4.62• - _ 32mm (1224 cm) • 1.25" / (4.69 an) �l' (3.18 mm) , - _ 1 Lin% CD it,j . d• 5.67' 1141' 5.67' :-,,, . 4.68 1an).^-- 69 O (14.4 cm) 144 144 mm �,y �,� _ I= _ A0550-00 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* ""--> P2RL 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL 2-Wire,Horn Strobe,White HWL* Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO • SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 ©2018 System Sensor. �'� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change vithout notice.Visit systemsensorcom for current product information,including the latest version of this data sheet. www.systemsensor.com AVDS865-05.2/22/2018 July 14, 2004 DF-50628• F-200 ej Fire-Li-Tee ALarms BG-8 Series Manual Fire Alarm Pull Stations www.firelite.com Section:Conventional Initiating Devices GENERAL California The Flre•Lite Alarms BG-8 Manual Fire Alarm Pull Station �` 0 State Fire provides a single-action, normally-open contact alarm ini- Marshal tiating point for use with UL listed Fire Alarm Control Pan- LISTED 7150-0075:148 els. CS115 FEATURES S711 MEA ADA 28-93-E • Complies with Americans with Disabilities Act. • Sturdy metal construction. • Simple operation. • Operation does not require replacement of parts. • Drawing of flames on cover helps communicate pur- pose of this device to people who do not read English words. • Designed to prevent false alarms when bumped,shaken, or jarred. • Listed to UL 38. PU '.1. APPLICATIONS Designed for indoor use in atmospheres which are not po- tentially explosive. Use as a means of allowing anyone on the premises to turn in a non-coded alarm quickly,without 1v chance of error. Typical uses include: 1. Schools. 2. Hospitals. 3. Retail stores. 4. Industrial plants. 5. Warehouses. Compatible with any appropriate control panel to: 1. Initiate local alarm signals. 2. Trip a municipal fire alarm box. 3. Start fire pumps. FIRE 4. Any other function that can be initiated or controlled by the closing of a switch contact. OPERATION The stations feature non-break-glass operation. They are ALARM operated by a pull on the pull cover.This causes a key latch to act against a retaining mechanism until adequate force is applied to open the station.As the station opens,a switch is released to initiate an alarm. The retainer in Model BG- F l re•L I Te®A La r m s 8 is a permanent, high-tensile,flat spring,which eliminates the need for a glass retainer.When so operated,the cover hangs down (and cannot be reset without use of a reset BG-8(shown full size) key)indicating that the station was used to initiate an alarm. OPERATED STATIONS CAN BE SEEN UP TO 100 FEET AWAY. The attractive design of the stations highlights their engi- Fire•LitelD Alarms is a Honeywell company. This document is not intended to be used for installation purposes, We try to keep ISO 9001 our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to G E R T F E O change without notice. N6INEHIN6 8 NIANUFAC1UlUll� For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, E U A L 1 T Y SYSTEMS Made in the U.S.A. Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. DF-50628•07/14/04 — Page 1 of 2 , neered simplicity and unusual dependability; bumping, PRODUCT LINE INFORMATION shaking, or jarring will not activate the switch or circuit. In- Model Description structions for operation of the station are clearly marked on the front of the pull cover. BG-8 Manual Fire Alarm Pull Station. Single-action. The BG-8 Station is die-formed from 1/8"thick satin finish Normally-open contact. aluminum, with the operating instructions in raised letters. BG-8SP SPANISH Manual Fire Alarm Pull Station, with • BG-8 contacts rated at: 1 amp., 30 VAC, and 30 VDC. FUEGO(FIRE)and JALE(PULL)in large capital Master key fits all stations used in an installation of the letters. Single-action. Normally-open contact. same series. BG-2R Surface mounting backbox for BG-8 Series sta- 1 INSTALLATION tions. One end tapped for 1/2" conduit. Color: The station mounts with two screws (supplied) to a stan- dard single-gang electrical switch box. It can also be 17003 Key. mounted to a surface mount box. 6" wire leads are pro- vided for making easy connections. ARCHITECT/ENGINEERING p, SPECIFICATIONS t Manual Fire Alarm Stations shall be non-code, non-break- A i iglass type equipment with a key operated reset, and so PU I L. designed that after actual Emergency Operation,they can- not be restored to normal except by use of a key.An oper- ated station shall be designed such that upon activation, /) it will be visually detectable at a minimum distance of one ` :2) 1 hundred feet, front or side. Manual Stations shall be con- ='' 1 structed of die-formed aluminum,with operating directions provided on the front cover in raised letters.The word FIRE shall appear on the front of the stations in raised letters, 1 ;; 4 five-eights inch high or larger. Stations shall be suitable jj for surface mounting on matching backbox, or semi-flush @ `i FUEGO mounting on a standard single-gang box or switch plate, r' and shall be installed within the limits defined by the Ameri- cans with Disabilities Act(ADA)dependent on manual sta- tion accessibility or per local requirements. Manual Sta- tions shall be Underwriters Laboratories listed. 3 ,, ^ n p�q H ARM I ( `ire uTe' aiarms ii BG-8SP 7 O C 5/8"(1.59) 1-3/8" 1-1/2" 3-1/4" />"-. '\/(3.49) (3.81 cm) 8.25) - • 4" - 40 C) (10.16) „0"L'4;'1"' ,, 3-1/4" From previous To next oa, (8.25) station or station or "L., ""' , fire alarm end-of-line I control panel. device. BG-8/BG-8SP(Rear View) BG Series Backbox Page 2 of 2 — DF-50628•07/14/04