Loading...
Report RECEIVED City of Tigard Allb 3 2021 1,11 Building Division ul Y OF TIGARD 13125 SW Hall Blvd,Tigard,OR 97223 iJII.DIRIG DIVISION' Phone: 503.718.2439 Fax: 503.598.1960 T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 17476 SW Clementine St City: Beaverton, OR Zip: 97007 Owner's Name: Robert Van Der Hoest Date: 8/3/2021 Contractor's Name: Conduit Electric CCB #: 109669 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ElYes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 ps r less? structures other than If"Yes", qualifies for Yes the prescriptive path. above ❑ No 1 I:/Building/Fors/PhotoVoltaic-Checklist02-01-11.docx Is the construction material wood and does Yes Type of If"Yes", qualifies for the construction qualify No the prescriptivepath. Construction as "conventional light ❑ frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. 6,Z If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max.two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly If the solar assembly connected to roof No the prescriptive qptifies for to the roof framing or blocking ❑ the path. directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist02-0I-I I.docx ® Yes If"Yes", qualifie• for Is 'e gauge 26 or less? ❑ No the prescriptive Bath. 115 lbs for 60 inch spacing or less? If"Yes' , qualifies for ® Yes the prscriptive path. ❑ No Minimum Uplift .ting of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Attachment of roof mounted Mini I um 4 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to 48 inches Maxi 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or -ss is less than 18 inches, 18 inches qualifies for the prescriptive path. Minimum #10 at 24 inches o/c? Size and spacin: of If"Yes", qualifies for ��r fastener? ® Yes . e prescriptive path. p\' �u ❑ No Is the roo'decking of WSP mi %"thickness, ® Yes decki _ connected to If"Yes", q ifies for ing members ❑ No the prescripti e path. min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 1:/Building/Forms/PhotoVoltaic-ChecklistO2-01-I I docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:ZNSHI NE Model Number:ZXM6-NH 120-360/M Listing Agency:61730 4 I:/Building/Fomts/PhotoV oltaic-Checklist02-01-I I docx