Report (2) BLuQcli OFFICE COPY RECEIVED SEP272021 CITY OF TIGARD `ieeZ02/-007SI/ BUILDING DIVISION //6-0/ &az inr Jacobs Heating and Air Conditioning Inc. Submittal Packet Array Apts WO# 51320 TABLE OF CONTENTS Job Name:Array Apts Job No. 51320 Submittal Packet DESCRIPTION Section Tab Carrier High Wall Heat Pump Ductless System Outdoor Model: 38MGRQ18B- -3 HP-1 BLDG E Indoor Model: 40MAHBQ09XA3 FC-1B BLDG E/Mailroom Indoor Model: 40MAHBQ12XA3 FC-1A BLDG E/Office 1 Panasonic WhisperGreen Ventilation Fan Model: FV-0511VKS2 EF-1 Restrooms 2 Broan® FIexTM Series Fan Model: A80 EF-2 BLDG E/Office Restiin 3 BroaniD Losone Select®Ceiling Mount Ventilator Model: L200 EF-3 BUILDING A/ 1st Fl 4 Markel®Hotpod Duct Mounted Heater Model: HP8-1440120-2T SF-1 BUILDING E 5 HEATING &AIR CONDITIONING TAB 1 fa-U3 Jacobs Heating and Air Conditioning Inc r .. Outdoor Unit Multi-zone Heat Pump Ductless System Outdoor Model: 38MGRQ18B--3 Submittal Data Job Data: Location: Buyer: Buyer P.O.#: Carrier#: Unit Number: Model Number: Performance Data Certified By: Date: MULTI-ZONE STANDARD FEATURES '�, Features Outdoor: •Connect 2,multiple style indoor units c ^Sly\�a`�•• a High Wall �^`^.. `��� Cassette Ducted lf�= Console lliad} ak‘k`����~� //�f lr •Variable Speed(Inverter)Compressor �NAt •Basepan Heater factory installed �\ ./1 •Quiet operation •Aluminum Hydrophilic pre-coated fins Cooling operating range-13°-122°F(-25°-50°C) Heating operating range-22°-86°F(-30°-30°C) LIMITED WARRANTY* El •10 year limited to original purchaser on compressor and parts upon timely registration,otherwise 5 years `For residential applications.See warranty for full details. EN[RGYSTAR Compatibility Table For matched compatibility see Product Data INDOOR UNIT 40MPHAQ09XA3 619PHAQ09XA3 DHMPHAQ09XA3 PHASED OUT 40MPHAQ12XA3 619PHAQ12XA3 DHMPHAQ12XA3 INDOOR UNITS 40MAQB09B--3 619PE0009BBMA DHMSHAQ09XA3 High Wall 40MAQB12B--3 619PEQ012BBMA DHMSHAQ12XA3 40MAHBQ09XA3 619AHBQ09XA3 DHMAHBQ09XA3 40MAHBQ12XA3 619AHBQ12XA3 DHMAHBQ12XA3 40MHHQ09---3 4OMHHQ12---3 Cassette 40MBQB09C-3 619REQ009CBMA 40MBCQ09---3 40MBQB12C-3 619REQ012CBMA 40MBCQ12---3 Ducted 40MBQB09D-3 619REQ009DBMA 40MBDQ09---3 40MBQB12D-3 619REQ012DBMA 40MBDQ12---3 Console 40MBQB09F-3 619REQ009FBMA 40MBFQ09--3 40MBQB12F-3 619REQ012FBMA 40MBFQ12---3 Copyright 2021 CACIBDP•Atlanta,GA 30339 Edition Date:01/2021 Catalog No 3SMGR-18-04S6 SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces:38MGR-18-03SB Specifications Coding Outdoor DB Min- °F(°C) -13-122(-25-50) Size 18 Operating Max System Outdoor Model 38MGRQ18B--3 Range Heating Outdoor DB Min- °F(°C) -22-86(-30-30) Max Max Number of Zones 2 Total Piping Length ft(m) 131(40) Energy Star YES Piping to furthest FCU ft(m) 82(25) Cooling System Tons 1.5 Drop(OD above ID) ft(m) 49(15) Cooling Rated Capacity Btu/h 18,000 Piping Lift(OD below ID) ft(m) 49(15) Cooling Cap.Range Min-Max Btu/h 5,810-21,940 Pipe Connection Size in(mm) 1/4'2(6.35'2) Liquid SEER 22.5 Pipe Connection Size- in(mm) 3/8.2(9.52'2) Suction Performance EER 12.5 Type R410A Non-Ducted Heating Rated Capacity (47°F) Btu/h 19,000 Refrigerant Charge I lbs(kg) 4.41(2.0) Heating Maximum Capacity (5°F) Btu/h 14,400 Metering Device EEV Heating Cap.Range Min-Max Btu/h 5,760-24,480 Voltage,Phase,Cycle I V/Ph/Hz 208/230-1-60 HSPF 10.3 Power Supply Indoor unit powered Electrical from outdoor unit COP(47°F) W/W 3.6 MCA A. 18 COP(5°F) W/W 2.15 MOCP-Fuse Rating A. 25 Energy Star NO Type R410A Cooling System Tons 1.5 Model ATM150D23UFZ Cooling Rated Capadty Btu/h 18,000 Compressor Oil Type ESTER OIL VG74 Cooling Cap.Range Min-Max Btu/h 5,795-20,708 Oil Charge Fl.Oz. 17.64 Performance SEER 20.5 Rated Current RLA 10 Combination EER 12.15 Unit Width in(mm) 37.31(948) Ducted and Heating Rated Capacity (47°F) Btu/h 18,700 Unit Height in(mm) 27.64(702) Non-Ducted Heating Maximum Capacity (5°F) _ Btu/h 14,565 Outdoor Unit Depth in(mm) 14.82(376) Heating Cap.Range Min-Max Btu/h 5,650-24,365 Net Weight lbs(kg) 105.8(48) HSPF 10.15 Airflow CFM 1390 COP(47°F) W/W 3.7 Sound Pressure dB(A) 62.4 COP(5°F) WNV 2.125 Energy Star NO Cooling System Tons 1.5 Cooling Rated Capacity Btu/h 18,000 Cooling Cap.Range Min-Max Btu/h 5,780-19,476 SEER 18.5 Performance EER 11.8 Ducted Heating Rated Capacity (47°F) Btu/h 18,500 Heating Maximum Capacity (5°F) Btu/h 14,730 Heating Cap.Range Min-Max Btu/h 5,539-24,249 HSPF 10 COP(47°F) W/W 3.8 COP(5°F) WNV 2.1 Rated Combinations Two Zones 9+9 9+12 12+12 Copyright 2021 CAC/9DP•Atlanta,GA 30339 Edition Date:01/2021 Catalog No:38MGR-18-04SB SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces:38MGR-18-03S8 Construction View Outdoor Model: 38MGRQ18B--3 6 :74'.-------. 11 .n. r 1 ' • ` ' •71... ?'"7'71777::4 :.-..:»77..1, 7f2 -'- -4, „' ‘ . 1 / ',,,,i, •, ",,,,' '.....t..:',Nb. \--;-• \\ 1 ,r- \ i i • \ 7 7 7s.'`7.7'77. 7.,"7 '' 1•„:,77: '-",;7" '7/77,7 / 11 7'4'77.,7'7,, ,...7,7,7E7-„•-, ,..<5''7%77' 7 1 I - '-' ,__. t-ri —•--7 „ ' ----'1. T.1.-7IY -'7'77' 77) 1 .1,77Fs7,-/4,.. , J,1.7 7 ,1,' 33 F/(845) 8 1 , .. - • i , I V, ______ ___ ______ 4_______ § / I ,..., , ___ -• , . • in !I o •, ,. ,..„ , I _ 1 I § ,, (--, i % \ J -7, I / \*,,,,r, .r.---- ____ ____ ........ 7.7.../ '.'' - 1 ' 1 , 1 , . .-, - - :-: l ''. . .t.OPOW1-1 - LI 4/(Y; .., (E.....r., tT1),,.c . figAehrtgOINIM''.,' ' Copyright 2021 CAC/BDP•Atlanta,GA 30339 Edition Date 01/2021 Catalog No 38MGR-18-04SB SUBJECT TO CHANGE WITHOUT NOTICE Page 4 Replaces.38MGR-I 8-03SB High Wall Heat Pump Ductless System Carrier Indoor Model: 40MAHBQ09XA3 MAIL ROOM Submittal Data Job Data: Location: Buyer: Buyer P.O.#: Carrier#: Unit Number: Model Number: Performance Data Certified By: Date: STANDARD FEATURES •Modes: Cool, Heat, Dry, Fan,Auto •Turbo Mode •Four fan speeds •Sleep Mode •Relative Humidity Sensor •Intelligent Eye(Occupancy Sensor) •ECO Mode •Up-Down Louver control (fixed or swing) •Follow Me(senses temperature at handheld remote) •Heating Setback(46° F Heating Mode) •Quiet indoor operation •Aluminum Golden Hydrophilic pre-coated fins CONTROLS: •Wireless Remote Controller included with indoor unit Perk Orrnance' LIMITED WARRANTY* SERIES • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. System Size 9 Face Area Sq.Ft. 2.15 Indoor Model 40MAHBQ09XA3 No.Rows 2 Indoor Coil Voltage,Phase,Cycle V/Ph/Hz 208/230-1-60 Fins per inch 20 Electrical Power Supply Indoor unit powered by outdoor unit Circuits 3 MCA A. 0.3125 Unit Width in(mm) 31.3(795) Wireless Remote Controller(°F/°C Convertible) Standard Unit Height _in(mm) 11.61 (295) Controls Wired Remote Controller(°F/°C Convertible) Optional Unit Depth in(mm) 8.86(225) Operating Cooling Indoor DB Min-Max °F(°C) 63-90(17-32) Net Weight lbs(kg) 22.71 (10.3) Range Heating Indoor DB Min-Max °F(°C) 32-86(0-30) Number of Fan Speeds 4 Pipe Connection Size-Liquid in(mm) 1/4(6.35) Airflow(lowest to CFM 176/229/335/382 Piping Indoor highest) Pipe Connection Size-Suction in(mm) 3/8(9.52) Sound Pressure(lowest dB(A) 32/34/38/47 to highest) Air throw Data ft(m) 24.9(7.6) Moisture removal (L//h) 0.75(0.35) Field Drain Pipe Size in(mm) 0.625(16) O.D. Performance may vary based on the outdoor unit matched to.See compatible outdoor units pages for Performance Data. For Compatibility See Product Data Copyright 2021 Carrier Corporation•7310 W.Morns St Indianapolis,IN 46231 Edition Date:02/2021 Catalog No:SUB40MAHB-09302 SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces:SUB40MAHB-09-3-01 Accessories KSACN0801AAA Wired Remote Control 7 Day Programmable KSACNO101AAA Wired Remote Control with Timer Function KSAIF0601AAA WI-Fin'Kit High Wall Mid-Tier KSAIC0301230 24V Interface Kit 230V Construction View Indoor Model: 40MAHBQ09XA3 Unit Width in(mm) 31.3(795) Unit Height in(mm) 11.61 (295) Unit Depth in(mm) 8.86(225) Net Weight lbs(kg) 22.71 (10.3) CERTIFIED, c C��VAlOUS O Smen ANPo HV ere m,e�y Stand'd 210/240 Copyright 2021 Cartier Corporation•7310 W.Moms St Indianapolis,IN 46231 Edition Date:02/2021 Catalog No:SUB40MAH8-09-302 SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces:SUB40MAHB-09-3-01 a High Wall Heat Pump Ductless System Carrier Indoor Model: 40MAHBQ12XA3 OFFICE Submittal Data Job Data: Location: Buyer: Buyer P.O.#: Carrier#: Unit Number: Model Number: Performance Data Certified By: Date: STANDARD FEATURES •Modes: Cool, Heat, Dry, Fan,Auto •Turbo Mode •Four fan speeds •Sleep Mode •Relative Humidity Sensor •Intelligent Eye(Occupancy Sensor) •ECO Mode •Up-Down Louver control (fixed or swing) • Follow Me(senses temperature at handheld remote) • Heating Setback(46° F Heating Mode) 0 •Quiet indoor operation •Aluminum Golden Hydrophilic pre-coated fins _/;I CONTROLS: •Wireless Remote Controller included with indoor unit Performance LIMITED WARRANTY* SERIES • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. System Size 12 Face Area Sq.Ft. 2.15 Indoor Model 40MAHBQ12XA3 Indoor Coil No. Rows 2 Voltage,Phase,Cycle I V/Ph/Hz 208/230-1-60 Fins per inch 20 Electrical Power Supply Indoor unit powered by outdoor unit Circuits 3 MCA A. 0.3125 Unit Width in(mm) 31.3(795) Controls Wireless Remote Controller(°F/°C Convertible) Standard Unit Height in(mm) 11.61 (295) Wired Remote Controller('F/°C Convertible) Optional Unit Depth in(mm) 8.86(225) Operating Cooling Indoor DB Min-Max °F(°C) 63-90(17-32) Net Weight lbs(kg) 22.93(10.4) Range Heating Indoor DB Min-Max °F(°C) 32-86(0-30) Number of Fan Speeds 4 Pipe Connection Size-Liquid in(mm) 1/4(6.35) Airflow(lowest to CFM 176/229/335/382 Piping Indoor highest) Pipe Connection Size-Suction in(mm) 1/2(12.7) Sound Pressure(lowest dB(A) 30/32/37/47 to highest) Air throw Data ft(m) 26.2(8.0) Moisture removal Pint/h/ : 2.333(1.11) Field Drain Pipe Size n(mm) 0.625(16) O.D. Performance may vary based on the outdoor unit matched to.See compatible outdoor units pages for Performance Data. For Compatibility See Product Data Copyright 2021 Carrier Corporation•7310 W.Morns St. Indianapolis.IN 46231 Edition Date:02/2021 Catalog No:SUB40MAHB-12-3-02 SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces:SUB40MAHB-12-3-01 Accessories KSACNO801AAA Wired Remote Control 7 Day Programmable KSACN0101AAA Wired Remote Control with Timer Function KSAIF0601AAA WI-Fin'Kit High Wall Mid-Tier KSAIC0301230 24V Interface Kit 230V Construction View Indoor Model: 40MAHBQ12XA3 11: : tiii H Unit Width _ in(mm) 31.3(795) Unit Height in(mm) 11.61 (295) Unit Depth in(mm) 8.86(225) Net Weight lbs(kg) 22.93(10.4) ::'� i CERTIFIED„auacto.y.ora C is Unitary Small HP HHNI StandarH 210/240 roi�M-v•neome.M,ryma.ni.,. Copynghl 2021 Carnet Corporation•1310'W Morris St Indianapolis,IN 46231 Edition Date:02/2021 Catalog No:SUI34OMAHB-I2-3-02 SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces:SUB40MAH1312-3-01 TAB 2 • Fe% Jacobs Heating and Air Conditioning Inc , h• sper r et`�Cjeeeet'" Buin-In�fAdust FV-0511VKS2 VENTILATION FAN Arffrnv(apabi" Specification Submittal Data/Panasonic Ventilation Fan Description Customizable ceiling mount ventilating fan, low sone and rated for continuous operation. ENERGY STAR®rated and certified by the Home Ventilating Institute(HVI).Evaluated by the 4" or 6" duct Underwriters Laboratories and conforms to both UL and cUL standards. Motor/Blower" •Enclosed brushless ECM smart motor technology rated for continuous operation •Adjustable ventilation rates at 50-80-110 CFM •Power ratingof 120 volts and 60 Hz 1111(1 •UL and cUL listed for tub/shower enclosure when GFCI p rotected, •Motor equipped with thermal cutoff fuse73/8 :rrl--,„� •Removable permanently lubricated plug-in motor radi tom » Housing: •Environmentally friendly 26 gauge housing using Zinc-Aluminum-Magnesium(ZAM)coating •Integrated dual 4"or 6"diameter duct adapter 101/4" 101i4" •Built-in damper reduces back draft and helps with blower door testing •Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier,and assists with the decrease in leakage in the Building Envelope during blower door testing •Suitable for installation in ceilings insulated up to R60 •Articulating and expandable installation bracket up to 24" Grille: •Attractive design using Poly Pro material 13• • 13 •Attaches directly to housing with torsion springs • Includes a motion sensor cap for use as a cover when the motion sensor Plug 'n Play" module has not been selected Warranty: •ECM Motor:6 Years from original purchase date •ALL Parts:3 Years from original purchase date FV-0511 VKS2 Architectural Specifications: Customizable ceiling mount ventilation fan,ENERGY STAR"rated with multi-speed control(0, 30-100 CFM,in 10 CFM increments)and a built-in high/low adjustable time delay activated by a wall switch,SmartAction Motion Sensor Plug'N Play'module or Condensation Sensor Plug'N Performance Curve 4"or 6"duct Play"module.Features a built-in speed selector.Select from 50/80/110 CFM with<0.3 sone as o .70 certified by the Home Ventilating Institute(HVI)at 0.1 w.g.with 51/80/110 CFM and no more than 0.4/0.5/0.8 sons at 0.25 w.g.and 51/79/108 CFM at 0.375 wg.Power Consumption shall be no greater than 3.1/5.1/9.9 watts at 0.1 w.g.and 6.2/9.6/15.4 watts at 0.25 w.g.and 9.6/13.4/20.0 watts at 0.375 w.g.ENERGY STAR®rated with efficiency of no less than 16.2/15.7/11.1 CFM/ — mM watt at 0.1 w.g.and 8.3/8.3/7.1 CFM/watt at 0.25 w.g.and 5.3/5.9/5.4 CFM/watt at 0.375 •-••••900.4 •w.g.The motor shall be enclosed with brushless ECM motor engineered to run continuously. I o,„f __ Fa ECM motor speed shall automatically increase when the fan senses static pressure to maintain I selected CFM.Power rating shall be 120v/60Hz,Duct diameter shall be no less than 4",inclusive Y j • sa" of an integrated dual 4"or 6"duct adapter.Plug'N Play"modules provide up to two additional i i features.Select from Condensation Sensor,and SmartAction Motion Sensor.Fan shall be RoHS m °^°wl Compliant and UL and cUL listed for tub/shower enclosure when GFCI protected.Also suitable • for installation in ceilings insulated up to R60.Fan can be used to comply with ASHRAE 62.2, ol LEED,ENERGY STAR",IAP,EarthCraft,California Title-24 and WA Ventilation Code. I o.m j o 10 :o m a SO 60 70 eo w rm n" im 4 o� ECM Motor Technology: Ab"."•i NF When fan senses static pressure, its speed is automatically increased to „ro.."„Wks/w.`.ror.,.,,".1..ozo•eoa„ ensure that the desired CFM is not compromised, which allows the fan to perform as rated. Model Quantity Comments Project: Location: Architect: EF-1 Restrooms with motion sensors Engineer: Contractor: t Submitted by: Date: For complete Installation Instructions visit us.panasonic.com/ventfans Ceiling Radiation Damper:WhisperGreen Select"is UL Hated for use with the Panasonic Ceiling Radiation Damper(Model A:PC-RD05C5,sold separately). Whisper FV 0511VKS2 sGVQLV BuBt-In Self Adjusting VENTILATION FAN Airflow C,apabilrty Plug 'N PIayTM Modules Plug 'N Play'" modules provide up to two additional features (multi-speed is already built-in to FV-0511VKS2). Select from Motion Sensor and Condensation Sensor. FV-VS15VK1: Multi-Speed with Time Delay - N/A for this Fan, already built-in. 11111 Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level(0,30-100 CFM,in 10 CFM increments),then elevates to a maximum level of operation (50-80-110 CFM)when the wall switch is turned on,or when the motion sensor or Condensation Sensor module is activated. A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. I f q FV-MSVK1: Motion Sensor r etair, Automatically activates when someone enters the room.Once the settings have been applied,the fan becomes truly automatic. •fi This module also activates a 20 minute delay off timer for the fan. FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew.Sensor technology detects relative humidity and temperature °;4 to anticipate dew point,automatically turning the fan on to control humidity.Built-in Relative Humidity(RH)sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements.When the condensation sensor is used in conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor detects moisture in the room.This module also activates a 20 minute delay off timer for the fan. Fan Specifications WhisperGreen Select'":FV-0511VKS2 Static Pressure in inches w.g. 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 Air Volume(CFM) 110 110 108 100 101 101 90 90 90 80 80 79 70 71 Noise(sones) <0.3 0.8 - <0.3 0.7 - <0.3 0.6 - <0.3 0.5 - <0.3 0.5 Power Consumption(watts) 9.9 15.4 20.0 7.9 13.1 17.8 6.5 11.2 16.0 5.1 9.6 13.4 4.3 8.5 Energy Efficiency(CFM/Watt) 11.1 7.1 5,4 12.7 7.7 5.7 13.9 8.0 5.6 15.7 8.3 5.9 16.7 8.5 Speed(RPM) 920 1182 1356 889 1164 1356 839 1135 1351 795 1113 1315 760 1112 Current(amps) 0.10 0.16 0.20 0.09 0.14 0.18 0.07 0.12 0.16 0.06 0.10 0.14 0.05 0.09 MAX.Current(amps) 0.20 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes *Industry research indicates static pressure in typical installations ranges from 0.20"to 0.375" Panasonic Life Solutions Company of America Most Efficient � IAQ Division 2020 Two Riverfront Plaza Newark,NJ 07102 '"'""`""'rytl"'^ us.panasonic.com/venffans HVI cOus Panasonic IAQ19071SS r3 TAB 3 oficoBs Jacobs 1 kitting and zlir Conditioning Inc IIII 1 A BRVi N SPECIFICATION SHEET MODELSA8O � ' ' ° . Ia � �_. • la FLEXTM SERIES FANS DESCRIPTION TYPICAL SPECIFICATION BLOWER: Fan shall be Broan Model A80(A110). • Plug-in,permanently lubricated motor-engineered for Fan shall have corrosion resistant galvanized steel housing continuous operation with four-point mounting capability.It shall be ducted to a • Dynamically balanced centrifugal blower wheel for quiet, roof or wall cap using 4"round ductwork. efficient performance Blower assembly shall be removable, have a centrifugal- • Low RPM for quiet operation type blower wheel and a permanently lubricated motor HOUSING: designed for continuous operation. • Rugged,26 gauge,galvanized steel construction Non-metallic damper/duct connector shall be included. • Polymeric,4"duct connector with tapered sleeve and no Air delivery shall be no less than the airflow values and metallic clatter no greater than the sound level values listed in the HVI • 53/4"height allows for 2"x 6"ceiling installations Performance Specifications provided in this specification • Sturdy,easy,four-point mounting directly to joist (see following chart).All air and sound ratings shall be • Can be mounted in ceilings up to 7/12 pitch certified by HVI. • Can be installed in a wall if mounted 8-ft.or more above Ceiling Ventilator shall be U.L.Listed for use over bathtubs the floor and showers when connected to a GFCI protected branch GRILLE: circuit. • Polymeric construction • Innovative design-the result of extensive research with designers and consumers CONTROLS(Purchase separately): 21001, • Refer to Broan's catalog for a complete line of C UI. us HUI accessories to effectively adapt these fans to your CERTIFIED construction requirements. U.L.Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit(ceiling mount only). 1-Year Warranty Broan Hartford,Wisconsin www.broan.com 800-558-1711 Venmar Ventilation ULC Drummondville(Quebec), Canada www.broan.ca 877-896-1119 REFERENCE QTY. REMARKS Project Location EF-2 Model: A80 Architect Engineer Contractor Submitted by Date 91D 99045370D PERFORMANCE RATINGS FLEXTM SERIES FANS HVI PERFORMANCE ELECTRICAL & WEIGHT 0.1 Ps-Static Pressure(in.H20) 0.25 Ps Model Volts Hz Amps Shipping Model Airflow Sound Power Efficacy Airflow _ Weight (CFM) (Songs) (Watts) (CFM/W) (CFM) LA80 120 60 0.37 10.0 lb. A80 80 2.0 43.1 1.89 67 A110 120 60 0.40 10.0 lb. A110 110 _-T 3.0 47.3 2.36 102 ® HVI-2100 CERTIFIED RATINGS comply with new 2100 111, testing technologies and procedures prescribed by the HVIHome eentilat ble to tituteumers.the-shelf products,as they are available to consumers.Product performance s rated at 0.1 in. static pressure, based on tests CERTIFIED conducted in a state-of-the-art test laboratory.Songs AIR FLOW PERFORMANCE area measure of humanly-perceived loudness,based on laboratory measurements. Model A80 0.6 , 0.5 C UI us ig d 0.4 3 W 3 y H� n`�. a 0.3 U-C R C it 41.1. rn 0.2 0 .hi es ' 0.1 l 1 6� 0.0 �.KM4",II' ' l e 0 10 20 30 40 50 60 70 80 90 100 1141111111) �� Air Flow(CFM-Cubic Feet per Minute) 0 4 `ml 4 Model A110 �� >,, 0.6 dK. 0.5 5 0.4 .. •- O v NOTE:Dimensions shown are in inches. a a i 0.3 - - u) c i0.2 - .. 0.1 \1/4\: 0.0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Air Flow(CFM-Cubic Feet per Minute) B R A Bro Hartford, a v� Venmaran VentilationWisconsin ULC Drummondville www.bro (Quebecn.com ),Canada www.broan.ca 877-896-1119 TAB 4 aRTFB3 Jacobs I leating and Air Conditioning Inc . , E Lo5oiie - SPECI FICATION SHEET LOSONE SELECT® i:,, E itr/ r- CEILING MOUNT VENTILATORS L200, L250, L300 SERIES, L300KMG =- Incredibly reliable.Unbelievablyquiet.OfferingtheCFMchoices TYPICAL SPECIFICATION you need at the lowest sound levels in the industry. Ventilator shall be Broan Model L200, (L200MG), (L250), FEATURES (L250MG), (L300), (L300KMG). GRILLE: Ventilator shall have galvanized steel housing insulated • Conceals interior with at least 1/2" of acoustic insulation (with no insulation • Low profile styling blends with any decor - Model L300KMG). Housing to have adjustable mounting • White polymeric("MG"models-metal,finished with white brackets. painted enamel) Automatic backdraft damper to be located within duct BLOWER: connector. Duct connector, blower assembly, and wiring • Low RPM for quiet operation plate shall be adjustable for either horizontal or vertical • Resilient anti-vibration mounts installation. • Dynamically-balanced,polymeric, centrifugal blower Blower unit shall be removable from housing and will have wheel for quiet, efficient performance(Model L300KMG- a polymeric, dynamically balanced centrifugal-type blower metal wheel) wheel.Motor to be permanently lubricated and mounted with • Permanently lubricated,thermally protected motor resilient anti-vibration mounts. RPM not to exceed number • Plug-in motor rated at 120 VAC listed for each model. • Designed for continuous operation Air delivery shall be no less and sound levels no greater HOUSING: than listed for each model.All air and sound ratings shall be • Rugged,20 gauge galvanized steel certified by AMCA. Units to be UL and cUL listed. • 8"round duct connector • 1/2"acoustic insulation inside(Model L300KMG-no insulation-for kitchen applications) • May be installed in ceiling or wall (size permitting) amca "groan-NUTone LLC certifies that the models shown herein are • 8-position mounting brackets for easy installation and s licensed to bear the AMCA Seal. greater adaptability to various mounting requirements The ratings shown are based on tests and procedures performed in • Automatic backdraft damper located within duct ` accordance with AMCA Publication connector Is. 211(and AMCA Publication 311 if sound is also certified)and comply • Factory-shipped in horizontal discharge position-easily mop, with the requirements of the AMCA converted to vertical discharge KO o r'�o me Certified Ratings Program" • May be installed as an in-line ventilator with addition of "'" " " accessory kit Model 981 L(purchase separately) ACCESSORIES(purchase all separately): • Model 57V(Ivory)/57W(White)3-Amp,Electronic Variable Speed Control • Model 59V(Ivory)/59W(White)60-Minute Time Control ,k C (111) • Model 61V(Ivory)/61 W(White) 15-Minute Time Control • Model 71 V(Ivory)/71W(White) 12-Hour Time Control • 6-Amp, Electronic Variable Speed Controls Models L200, L250, and Model 72V/72W(120 VAC) L300 are UL listed for use • Model 981 L In-line Adapter Kit over bathtubs and showers • Model RD1 Radiation Damper when connected to a GFCI- • Model LAF1 Grease Filter(for Model L300KMG) protected branch circuit. • Model 80L Electronic Speed Control(Internal) Broan-NuTone LLC,926 West State Street, Hartford,Wisconsin 53027(1-800-637-1453) Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, L5T 1 H9(1-888-882-7626) REFERENCE QTY. REMARKS Project Location EF-3 Model: L200 Architect Engineer Contractor Submitted by Date 60J 99042732J PERFORMANCE RATINGS - LOSONE SELECT° CEILING MOUNT VENTILATORS L200, L250, L300 SERIES, L300KMG AMCA LICENSED PERFORMANCE CFM/SONES-AT STATIC PRESSURES (Ps-inches of H2O) MODEL NOMINAL 0.0" .10" .125" .250" .375" .50" .625" .750" .875" 1.0" NOMINAL AMPS WATTS NO. VOLTAGE Ps Ps Ps Ps Ps Ps Ps Ps Ps Ps RPM @60 Hz L200 120 VAC CFM Hor. 231 214 210 196 186 177 165 144 113 51 740 1.8 127 , . SONES Hor. 1.6 1.8 1.7 2.3 2.9 3.5 4.1 4.9 5.3 5.3 CFM Ver. 224 210 207 197 187 179 167 144 99 41 760 1.8 127 SONES Ver. 1.5 1.8 2.0 2.3 2.7 3.4 4.0 4.5 5.1 5.2 L200MG 120 VAC CFM Hor. 237 218 215 199 190 180 167 144 108 47 715 1.8 127 SONES Hor. 1.4 1.8 1.9 2.4 3.0 3.6 4.2 5.1 5.6 5.5 CFM Ver. 228 213 209 198 190 182 168 145 105 56 730 1.8 127 SONES Ver. 1.5 1.7 1.8 2.3 2.8 3.4 4.1 4.6 5.1 5.2 L250 120 VAC CFM Hor. 272 261 259 250 242 233 218 201 165 99 830 2.1 166 SONES Hor. 2.1 2.3 2.2 2.9 3.3 3.9 4.4 4.8 5.5 5.8 CFM Ver. 269 261 259 253 248 239 224 203 171 101 860 2.1 166 SONES Ver. 2.3 2.6 2.7 3.0 3.3 3.7 4.2 4.7 5.4 5.6 L250MG 120 VAC CFM Hor. 280 267 265 254 246 238 224 209 172 105 805 2.1 166 SONES Hor. 2.1 2.5 2.5 2.9 3.4 3.9 4.3 4.6 5.6 5.9 CFM Ver. 275 263 262 255 250 241 229 210 178 105 830 2.1 166 SONES Ver. 2.2 2.6 2.7 3.0 3.4 3.8 4.3 4.8 5.5 5.8 L300 120 VAC CFM Hor. 312 309 308 303 296 287 273 254 219 125 905 2.6 212 SONES Hor. 2.8 2.9 2.9 3.3 3.5 3.9 4.3 4.7 5.1 5.6 CFM Ver. 319 314 313 306 299 288 274 251 219 120 940 2.6 212 SONES Ver. 2.6 2.9 3.0 3.4 3.6 3.9 4.4 4.7 5.0 5.5 L300MG 120 VAC CFM Hor. 323 317 316 312 305 298 283 266 235 153 860 2.6 212 SONES Hor. 3.0 2.8 3.0 3.2 3.5 3.9 4.3 4.8 5.2 5.7 CFM Ver. 322 315 314 308 302 292 278 259 227 119 885 2.6 212 SONES Ver. 2.4 2.7 2.8 3.3 3.5 3.9 4.3 4.7 5.1 5.5 L300KMG 120 VAC CFM Hor. 286 279 277 272 268 261 253 241 222 173 790 2.6 212 SONES Hor. 2.8 3.0 3.1 3.4 3.8 4.4 4.8 5.1 5.5 6.1 CFM Ver. 287 280 277 273 266 259 247 231 208 164 815 2.6 212 SONES Ver. 3.3 3.6 3.7 4.1 4.7 5.2 5.6 6.3 6.8 6.9 Performance ratings include the effects of inlet grille and backdraft damper in the airstream.Speed 1.00 (RPM)shown is nominal.Performance is based on actual speed of test. The sound ratings shown ‹ ,\` .are loudness values in fan sones at 5'(1.5m)in a hemispherical tree field calculated per AMCA Std. -. 0'90 CEO 301.Values shown are for Installation Type B:Free inlet fan sone levels.Performance shown is for 0 Installation Type B:Free inlet,Ducted outlet. 1 /.944...,, s `\ (0 "Broan-NuTone AfnCA 8, ,_ OR I N' I Z I z 0.80 a�s 1 WON LLC ertifies CERTIFIED that the models shown herein RRIIRGS p LCfO /� •- 0.70 are licensed to NO ` W N bear the AMCAmono C� tr 1 CC 0.60 N Seal. The rat- RIR 0Oings shown are '6`O""""" N based on tests re n 1 0 b 0.50 movrmcm J r and procedures mocoimon. II/� associanon.mc. W W performed in ac- 0.40 u' O cordance with _, "O , AMCA Publics- La.. tion 211(and AMCA Publication y311 if YYY • U 0.30 ' sound is also certified)and comply with illoo. G)the requirements of the AMCA Certified 17 0.20 Ratings Program." 1 . Q Models L200, I� Iq Ik 14 w 0.10 L250, and L300 ✓ \ {� are UL listed for �% �� I I 0.00 use over bathtubs ,:; --,���i 0 40 80 120 160 200 240 280 320 and showers when j connected to a AIR FLOW RATE (CFM) GFCI-protected branch circuit. POLYMERIC GRILLE METAL GRILLE WEIGHT MODELS MODELS MODEL NO. SHIPPING WT. L200,L250, L200MG,L250MG, L200 23.0 lbs. eill C ell L300 L300MG,L300KMG L250. L300 23.1 lbs. L200MG 23.9 lbs. L250MG,L300MG 24.0 lbs. L300KMG 25.2 Ilbs. BRA`A N P Groan-NuTone LLC,926 West State Street, Hartford,Wisconsin 53027(1-800-637-1453) v�r Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, L5T 1 H9(1-888 882 7626) TAB 5 it @J00063 Jacobs[leafing and Air ConditioningInc. IIII R SUBMITTALOMarkel Products Company HotPod Duct Mounted Heating Standard Features • 8"and 6"sizes available I hot pod • Use to heat cold rooms or additions without upgrading central system n • Fan only operation for increased CFM output for NC cycles '"' • 6"1000/500 Watt 'a} • 8"1440/720 Watt • Two stage operation +,..A.' • 120v corded and hard wire models available • 10'Cord length on corded models • Zero clearance for all models • All models include UT8003 low voltage thermostat . ,. �•-• • Optional wireless thermostat • Silent booster option available for rigid duct applications ' ;. °, • Silent boot can only be uses with rigid ductwork 1 i Standard HotPod Models ITEM# MODEL DESCRIPTION CFM WATTS VOLTS MCA LBS NOM DIMENSIONS 290074 HP6-1000120-2T 6"O INLET-HARDWIRE 130 1000/500 120v 8.33 4.0 11"X 9"X 6" 290043 HP6-1000120-2CT 6"0 INLET-WITH CORD 130 1000/500 120v 8.33 4.0 11"X 9"X 6" 290081 HP8-1440120-2T 8"0 INLET-HARDWIRE INLET 290067 HP8 1440120 2CT 8" 210 1440/720 120v 12.6 6.0 11"X 10"X 8" !?� WITH CORD 210 1440/720 120v 12.6 6.0 11"X 10"X 8" Additional Features Premium Components • Air flow through design • Integrated furnace control board 4.445E4,re,C • Quiet operation • Conformal anti-corrosion coating " • 1 year limited warranty • Heavy duty high cycle relays '°" E•S; • 50,000 hour operation rating • 24 Volt 10VA transformer E° "°'� il ; • Easy to install with no complicated • Low voltage fused protection "' ductwork or wiring • Self contained premium blower '_; • Economical alternative to conventional • High efficient motor zoning.Saves money,lowers heating bills • High temperature ball bearings and is easy to Install.Save on energy • High temperature thermal plastic fan blades rt costs by keeping one room warmer or • Premium safety discharge air limit cooler than the rest of the house with the • 100,000 cycle rating _' • '� sigummommosi energy efficient HotPod! • Blocked airflow safety limit so • so • 70 • so • so` • High gloss powder coat paint finish • 24 Gauge galvanized spiral steel body �. • Cast aluminum internal construction UT8003 Wall Mounted Thermostat Jacobs Heating - 4474 SE Milwaukie Ave - Portland, OR 97202 - JacobsHVAC.com