Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
i OFFICE COPY ' 4e'zoz f-oo7c9 718444-YTG-H-0414 � � YORK® 1s�, bu R 1VED SEr 15 2021 IDrMSRD iHeating and Air Conditioning BUILDING DIVISION TECHNICAL GUIDE Description R-410A These York®Affinity TPA packaged cooling/heating air conditioners are designed for outdoor installation. Only utility AF F I N ITY TM SERIES and duct connections are required at the point of installation. D N Z/D N Q/D N X MODELS The single or two stage gas-fired heaters have aluminized steel tubular heat exchangers and spark to pilot ignition.They are 2 - 5 TO N available in natural gas with field conversion to propane. 60 Hertz "- !III ill f, i - ' "« 1 t''I a - nf ill A �1��� f ., `I �., , @ 1 1 li ' j 1 4 ' 70�;�0 ate`" o'm. xI1 P , ' k i ,1Mook I I l i I € , �1 EE 1I 11,' 1 a ,-u- 4"4x �p spa y� ri- 'n`""r I ` I ,• +tf +ws" .:ate"" ^ ' """ a '€ i`. - ",� I i ' e (' $I `' ' 'oa it ,, d '"' Nr' I i 9' � _. k.,.. ��ar,Y. laaa Tested in accordance with: pE5l6p EFFICIENCY RATING ;�K__4411%.1) aCERIIfama IEU �'Fnrtft'�° C �.� --- r,, I Tr CEl TIFtED:jimirals, \'1 �' S� w,at+r1Qtra tory.arq - �� Vita REG]SCV I50 90l)1 Maim "nffflta ssiamomitiosav BBIwo»1Y�: �.k'ftlfe()C)41allty Management System FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 7 1 8444-YTG-H-0414 Table of Contents Description 1 Table of Contents 2 Component Location 2 Nomenclature 3 Features and Benefits 3 Guide Specifications 5 Physical Data 7 Capacity Performance 14 Airflow Performance 42 Sound Performance 54 Electrical Data 56 Typical Wiring Diagrams 58 Weights and Dimensions 78 Component Location Cooling/Gas Unit Direct Drive Blow-Through Design With �e="'��%�3, Condenser Fan Motor Reliable Aluminized Steel �� Tubular Heat Exchangers Highly Efficient Enhanced Copper %� Tube/Aluminurn Fin Evaporator Coil � Highly Efficient Enhanced Copper Tube/Enhanced Aluminum Fin LongLasting Powder Ij Ili OR Micro-Channel Aluminum Tube/Aluminum Fin Condenser Paint Finish Decorative Protective Coil Guard , ,, ' 11 V., i \ 4 �� (See"Features"for Details) Rear and Bottom Return Air J+ 40 High Efficiency and Supply Airduct Openings 1,,,, k . ♦ Pe) Compressor Rigidly -. i` ` I Mounted zi11 kiip t,i r let,(:� Pilot Assembly Heavy Gauge ,. / /' High Grade Aluminized In-Shot Burners Removable Base Rails �,a e Ili Low Voltage Terminal Block 0 0 Self-Diagnostic Controls Direct Drive Blower Motor With Slide-Out Blower Assembly Power Draft Motor Automatic Gas Valve(1/2"-NPTF) High Voltage Terminal Block # / 2 Johnson Controls Unitary Products I } l i It 718444-YTG-H-0414 Nomenclature li Cooling/Gas Unit IDt7INZ1036INI036I061 Product Category Voltage Code 0=Single Package Air Conditioner 06=208/230-1-60 25=208/230-3-60 Product Generation - 46=460-3-60 6=6th Generation1 Nominal Gas Heating Output Capacity 7=7th Generation (Nominal Low Gas Heat Output Capacity) Factory Installed Gas Heat Product Identifier N=Sile Stage 036.36,000 BTUH ng NZ=R-410A 13 SEER 0=Two Stage 065=56.000 BTUH(36,400 BTUH) 065=65.000 BTUH Gas Heat/Electric 072=72,000 BTUH(46,800 BTUH) NO=R-410A 14 SEER,12 EER Nominal Cooling Capacity(MBH) 090=90.000 BTIJH(56,160 BTUH) NX=R-410A 15 SEER 024=24,000 BTUH 04l.=42,000 BTUH 110=110.000 BTUH(70.200 BTUH) 1.All NZ Models,NO and NX 3 Phase Models 030=30.000 BTUH 048=48000 BTUH 036=36,000 BTUH 060=60,000 BTUH Features and Benefits with a minimum amount of field labor.A field supplied and field installed electrical disconnect switch must be installed. Standard Features • Convertible Airflow Design-The bottom duct openings are covered when they leave the factory ready to be used • Operating Efficiency-DNZ model gas units provide a for a side supply/side return application. If a bottom minimum AFUE of 80 and SEERS of 13.0. DNQ Model supply/bottom return application is desired,you simply gas units provide a minimum AFUE of 81 and 14 SEER/ remove the two panels from the bottom of the unit and 12 EERs. DNX model gas units provide a minimum AFUE place them in the side supply/side return duct openings. of 81 and SEERS of 15.0 to 16.5.All efficiencies exceed No panel cutting is required and no accessory panel is legislated minimum levels. necessary. Convertible airflow design allows maximum • On Site Flexibility-All model sizes share a common, field flexibility and minimum inventory. compact design cabinet in a single footprint.The installer • Condensate Pan-A non-corrosive, long-lasting,water- has the flexibility of setting one curb and placing the tight pan is positioned below the evaporator coil to collect proper tonnage unit on that curb after the internal load has and drain all condensate. Less collection of stagnate been determined. Field convertible duct connections from condensate will build-up.The condensate pan conforms side shot to down shot allows the installer to have greater to ASHRAE 62-89 standards(Ventilation for Acceptable flexibility with less inventory. Indoor Air Quality). • Lower Installation Cost-Installation time and costs are • Condensate Drain-The 3/4 inch NPTF connection is reduced by easy power and control wiring connections. rigidly mounted to assure proper fit and leak tight seal. The small base dimension means less space is required on the ground or roof, plus,the installer can fit this unit • Durable Finish-The cabinet is made of pre painted between the wheel wells of full size pick-up truck. steel.The pre-treated galvanized steel provides a better paint to steel bond,which resists corrosion and rust creep. All units are completely wired,charged with R-410A and Special primer formulas and matted-textured finish insure tested prior to shipment. Unique test stations using a new less fading when exposed to sunlight. state of the art computerized process system are used to • Full Perimeter Base Rails The easily removable base insure product quality. Refrigerant charge and component rails provide a solid foundation for the entire unit and part numbers are verified via computers at assembly.Vital protects the unit during shipment.The rails provide fork lift run test statistics such as system pressure, motor currents, air velocity and temperature,unit vibration,and access from all sides,and rigging holes are also provided gas system safeties are monitored and recorded by the so that an overhead crane can be used to place the units system to insure unit performance. on a roof.On applications where the unit is placed on a pad,the base will keep the unit off the pad to deter Equal size, side supply and return duct connections corrosion.On applications where height is limited,the inch allows easy hook-up of ducts to match low crawl spaces high base rails may be removed on location. without transition pieces. • More Attractive Appearance-A single piece Water ii • Utility Connections Made Easy-Gas and electric utility Shed top cover containing a top discharge condenser fan knockouts are provided through the bottom as well as the arrangement requires less square footage on installation side of the unit.Utility connections can be made quickly and and provides a wider variety of installations.The one piece design adds greater water integrity. Rounded Johnson Controls Unitary Products 3 7 j 8444-YTG-H-0414 corners with water drip edges add to the attractive transfer for maximum efficiency and durability or Micro- appearance.The cabinet panels have a non-fibrous Channel aluminum tube,aluminum fin for long lasting insulation that will not release insulation fibers into durability and efficient operation. conditioned area. • Heat Exchangers-Are corrosion-resistant,aluminized- • Top Discharge-The top discharge condenser fan does steel tubular construction to provide long-life, trouble-free not disrupt neighboring areas or dry-out vegetation operation.The unique blow-through design also assures surrounding the unit.The warm air from the top mounted fan that condensate does not collect in humid areas when in is blown up away from the structure and any landscaping. the cooling cycle.This adds to longer heat exchanger life This allows compact location on multi-unit applications. and higher long term efficiencies. • Condenser Coil Grille-All DNZ024 thru 060 and • Post Purge Induced Draft Combustion -Exhausts DNQ060 models utilize a decorative"Wire Form"coil combustion products from the heat exchanger upon guard to provide impact protection against large objects. completion of the heating cycle to prolong the heat DNQ024 thru 04,and DNX024 thru 048 models utilize a exchanger life. stamped"Louvered"design which provides superior • Self Diagnostic Fan Control Module-Due to this self impact protection against smaller objects during transit diagnostic control, less on site time is required to trouble and after installation. shoot these units. • Low Operating Sound Level The upward air flow • Spark To Pilot Ignition-Provides faster heat delivery. carries the normal operating noise up and away from the This ignition is highly reliable, durable and eliminates living area.The rigid top panel effectively isolates any nuisance lockouts. motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan • Multi Port In-shot Burners-No field adjustment is motor and compressor operating sounds.The unique required to mix the air and gas.These burners are formed base pan also aids in sound alterations with it's constructed of high-grade corrosion-resistant, aluminized- Super-Structure design.This design strategically places steel. embossments in the pan for optimum strength and rigidity. • Low Maintenance-Long life, permanently lubricated • Fan System-All models operate over a wide range of condenser and evaporator fan motor bearings need no design conditions with an electrically commutated fan annual maintenance adding greater reliability to the unit. motor.These units easily match all types of applications Blower assembly can be easily cleaned by the unique and provide greater on site flexibility to match comfort Slip-Track slide-out blower assembly. requirement.The cooling speed is factory set and can be • Secured Service Access Ports-Protected,externally field adjusted to a second speed.The heating speed is mounted, re-usable service access ports are provided on factory set to maintain mid point rise at the units heating both the high and low lines for ease of evacuating and input, but can be field adjusted. This allows maximum charging the system. No final field mounting required. comfort conditions. • Easy Service Access-A large, single panel covers the • Simple Control Circuit-A low voltage printed circuit electrical and gas controls makes servicing easy. The board contains a diagnostic indicator light and a low blower compartment has an additional large panel with a voltage terminal strip.An additional set of pin connectors built-in handle tab. Removing this panel will allow the is also provided to simplify the field interface of external blower assembly to slide-out for easy removal for controls. Mate-n-lock plug connectors are used.The maintenance and ease of trouble shooting. electrical control box is not located in the compressor compartment.The controls are mounted on a Control-Tilt • Replacement Parts-The installer requires no special control panel to allow the access cover to be removed for training to replace any of the components of these units trouble shooting and maintenance without affecting the and does not need to maintain an inventory of unique parts. normal system operating pressures.All wiring internal to • System Integration-Each unit has the internal ability to the unit is color/number coded. integrate an electronic air cleaner or humidifier to work in • Protected Compressor-The compressor is internally conjunction with the base unit. protected against high pressure and temperature.This is Field Installed Accessories accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect • Low NOx Kit-Kit includes all the necessary hardware the compressor if undesirable operating conditions occur. and instructions to field convert units to reduce emissions • Pressure Switches-High pressure and low pressure/ to less than 40 nanogram per Joule. California loss of charge switches standard in all units.When requirement on single phase models only. abnormal conditions are sensed through the pressure • Propane Conversion Kit-Kit includes burner orifices, switches,the unit will lock out preventing any further gas valve conversion and installation instructions operation until reset or problem is corrected. necessary to field convert unit from natural gas to propane. • Exclusive Coil Design-Grooved copper tubes and • High Altitude Conversion Kit(Natural Gas/Propane)-Kit enhanced aluminum fin construction improves heat includes all necessary labels and instructions to field alter I 4 Johnson Controls Unitary Products 718444-YTG-H-0414 units with natural gas/propane for installations above 2000 units can operate with single stage heat/single stage cool feet.Burner orifices must be obtained from Source 1 Parts. thermostats-with or without the economizer. Propane Conversion Kit must be obtained separately. • Low Ambient Kit-Kit provides necessary hardware to • Economizer Down Discharge/Supply Kit-Modulating convert unit to operate in cooling cycle down to 0°F. integrated economizer provides simultaneous operation Standard unit operation 45°F. between the mechanical cooling and economizer • Transformer Kit-Kit provides necessary hardware to operation. Independent blade design insures proper provide single phase models from factory furnished 40 VA control and less than 1%leak rate. Includes hood and transformer capability to 75 VA transformer capability. mesh bird screen filter integrated into the hood, dry bulb (Required on installations with economizer or motorized sensor and relief damper. Separate field accessories of damper.) single enthalpy and dual enthalpy are also available.A built-in barometric relief of 25%is provided. Guide Specifications • Single Enthalpy Sensor-Sensor replaces dry bulb sensor standard in economizer kit. Provides improved General economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of Units shall be manufactured by Unitary Products in an ISO the outdoor air. 9001 certified facility.YORK's Affinity TM package units give you • Dual Enthalpy Sensor-Additional sensor to single the flexibility and choices you need in today's market.These enthalpy sensor. Sensor senses both the return air packaged cooling/heating air conditioners are designed for temperature dry bulb and humidity in conjunction with the outdoor installation.Only utility and duct connections are single enthalpy to determine the most economical mix. required at the point of installation. The single or two stage gas Single Enthalpy sensor also required. fired heaters have aluminized steel tubular heat exchangers • Hail Guard Kit Kit contains protective grilles made of and spark to pilot ignition.They are available in natural gas with expanded aluminum with full perimeter frame. Sloped field conversion to propane. hoods are also included to assure maximum protection. Description • Anti Short Cycle Timer(DNZ Units Only)-Automatically prevents the compressor from restarting for 5 minutes after Units shall be factory-assembled, single packaged, Electric cycled off.Not required if Thermostat 2ET07700224 and Cooling/Gas Heating units,designed for outdoor mounted 2ET04700224 are used. installation. For SEER ratings,refer to technical literature.They • Filter/Frame Kit(Single Phase Only)-Kit contains the shall have built in,equal size,field convertible duct connections necessary hardware to field install return air filters into the for down discharge supply/return or horizontal discharge base unit. Pre-cut filter racks and appropriate cleanable supply/return.The units shall be factory wired, piped, charged standard size filters are shipped in one kit.The filter rack with R-410A Refrigerant and factory tested prior to shipment.All is suitable for either 1"or 2"filters.(1"filter is supplied) unit wiring shall be both numbered and color coded.All units This kit is available for single phase horizontal or vertical shall be manufactured in a facility certified to ISO 9001 duct application only. Standard in all 3 Phase models. standards, and the cooling performance shall be rated in accordance with DOE and AHRI test procedures.The heating • Motorized Fresh Air Damper-Designed for duct performance shall be rated to DOE and GAMA test procedures. mounted side supply/return and unit mounted down Units shall be CSA listed and classified to ANSI Z21.47/CAN/ supply/return applications. Damper capable of providing CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 0%through 50%of outdoor air(field supplied).Closes on conditions. power loss, includes hood and screen assembly. • Rectangle To Round Adapters-Kit includes one supply Unit Cabinet and one return air rectangle to round duct adapter. Unit cabinet shall be constructed of G-90,pre-paint textured Adapters are preformed and designed to fit over current duct openings on the base unit.Transition is from side steel, certified at 500 hours salt spray test per ASTM-B117 square duct opening to 14"round duct opening. standards.The unit top shall be a single piece"Water Shed" design,with drip edges and no-seam corners to provide • Roof Curbs NRCA approved curbs provide proper fit to optimum water integrity. Unit shall have a rigidly mounted base unit for rooftop installations. Curbs are designed to condenser coil guard to provide protection from objects and be assembled through hinge pins in each corner. Kit also personnel after installation. Indoor blower section shall be provides seal strip to assure a water tight seal. 8 and 14 insulated with up to 3/4"thick, aluminum,foil faced insulation, inch high roof curbs are available. fastened to prevent insulation from entering the air stream. • Manual Outdoor Damper-Provides 0%through 50% Cabinet panels shall be"large"size, easily removable for outdoor air capability(field adjustable). Designed for duct servicing and maintenance,with built-in lift handles. Unit shall mounted side supply/return applications. Includes hood be built on a formed, "Super-Structure"design base pan,with and screen assembly. embossments at critical points to add strength,rigidity and aid • Wall Thermostat-The units are designed to operate with in minimizing sound. Full perimeter base rails shall be provided 24-volt electronic and electro-mechanical thermostats.All to assure reliable transit of equipment,overhead rigging,for Johnson Controls Unitary Products 718444-YTG-H-0414 truck access and proper sealing on roof curb applications.Base Coils: rails shall be removable,when required,to lower unit height. a. Evaporator coils shall have aluminum plate fins Filters shall be furnished and be accessible through a mechanically bonded to seamless internally enhanced removable access door,sealed airtight. Units vertical discharge copper tubes with all joints brazed. and return duct configuration shall be designed to fit between standard 24"O.C. beams without modification to building b. Evaporator coil shall be of the direct expansion, blow structure,duct work and base unit. Condensate pan shall be through design. internally sloped and conform to ASHRAE 62-89 self-draining c. Condenser coils shall have aluminum plate fins standards,with 3/4" NPTF ridged mount connection. mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Mircro-Channel Indoor(Evaporator)Fan Assembly aluminum tube,aluminum fins. Fan shall be direct drive design.Fan wheel shall be double-inlet d. Condenser coil shall be draw through design. type with forward-curved blades,dynamically balanced to operate smoothly throughout the entire range of operation. Refrigerant Circuit and Refrigerant Safety Components shall Airflow design shall be constant air volume. Bearings shall be include: sealed and permanently lubricated for longer life and no a. Independent fixed orifice expansion devices. maintenance. Fan assembly shall be"Slip Track"(slide-out) b. Filter/strainer to eliminate any foreign matter. design for easy removal and cleaning. Outdoor(Condenser) Fan Assembly Gas Heating Section (If Equipped) The outdoor fan shall be of the direct driven propeller type, Heat exchanger and exhaust system shall be constructed of discharge air vertically, have aluminum blades riveted to aluminized steel and shall be designed with induced draft corrosion resistant steel spider bracket and shall be statically combustion with post purge logic and redundant main gas valve.The heat exchanger shall be of the tubular type, balanced for smooth operation. The outdoor fan motor shall be constructed of T1-40 aluminized steel for corrosion resistance totally enclosed with permanently lubricated bearings and and allowing minimum mixed air entering temperature of 40°F. internally protected against overload conditions. Burners shall be of the in-shot type,constructed of aluminum- Refrigerant Components coated steel.All gas piping shall enter the unit cabinet at a single location through either the side or bottom,without any Compressors: field modifications.An integrated control board shall provide a. Shall be fully hermetic type, direct drive, internally timed control of evaporator fan functioning and burner ignition. protected with internal high-pressure relief and over Heating section shall be provided with the following minimum temperature protection. The hermetic motor shall be protection: suction gas cooled and have a voltage range of+/- 10% a. Primary and auxiliary high-temperature limit switches. of the unit nameplate voltage. b. Induced draft pressure sensor. b. Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally isolated c. Flame roll out switch(manual reset). on a dedicated, independent mounting. d. Flame proving controls. 6 Johnson Controls Unitary Products V 718444-YTG-H-0414 1. Physical Data DNZ Single Stage Physical Data Component Models DNZ024 DNZ030 DNZ036 DNZ042 DNZ048 DNZ060 Nominal Tonnage 2.0 2.5 3.0 3.5 4.0 5.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point 24.7 30.8 35.6 43.0 48.8 59.5 (MBH) AHRI net capacity(MBH) 24.0 30.0 34.2 41.5 46.0 56.0 EER 11.6 11.5 11.1 11.6 11.00 11.00 SEER 13.2 13.2 13.2 13.4 13.0 13.0 Nominal CFM 850 940 1200 1300 1550 1600 System power(KW) 2.1 2.7 3.2 3.6 4.2 5.1 Refrigerant type R-410A R-410A R-410A R-410A R410A R410A Refrigerant charge(lb-oz) 3-10 4-0 4-0 4-14 4-8 5-2 AHRI HEATING PERFORMANCE Heating model N036 N056 N036 N056 N036 N056 N072 N065 N090 N065 N090 N110 N065 N090 N110 Heat input(K Btu) 45 70 45 70 45 70 90 80 108 80 108 135 80 108 135 Heat output(K Btu) 36 56 36 56 36 56 72 64 87 64 87 107 64 87 107 AFUE1 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Steady state efficiency(%) 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 No.burners 2 3 2 3 2 3 4 3 4 3 4 5 3 4 5 No.stages 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Temperature Rise Range(°F) 25-55 30-60 25-55 30-60 25-55 25-55 30-60 25-55 45-75 25-55 35-65 45-75 25-55 35-65 45-75 Gas Limit Setting(°F) 140 160 140 160 140 160 160 150 175 150 175 160 150 175 160 Gas piping connection(in.) 1/2 1/2 1/2 1/2 1/2 1/2 DIMENSIONS(inches) Length 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 Width 471/4 471/4 471/4 471/4 471/4 471/4 Height 331/2 331/2 331/2 411/2 411/2 41 1/2 OPERATING WT.(lbs.) Unit Weight(lbs.) 378 398 402 460 465 480 COMPRESSOR Type Recip 1-spd Recip 1-spd Recip 1-spd Recip 1-spd Scroll 1-spd I Scroll 1-spd CONDENSER COIL DATA Face area(Sq.Ft.) 11.9 11.9 11.9 15 15 15 Rows 1 1 1 1 1 1 Fins per inch 23 23 23 23 23 23 Tube diameter(in.) 0.71/18 0.71/18 0.71/18 0.71 /18 0.71/18 0.71 /18 Circuitry Type 2-pass Micro-Channel EVAPORATOR COIL DATA Face area(Sq.Ft.) 3.4 3.4 3.4 4.4 4.4 4.4 Rows 2 3 3 3 3 4 Fins per inch 15 13 13 16 16 13 Tube diameter 3/8 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced Refrigerant control Orifice Orifice Orifice Orifice TXV TXV CONDENSER FAN DATA Fan diameter(Inch) 22 22 22 22 22 22 Type Prop Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct Direct No.speeds 1 1 1 1 1 1 Motor HP 1/4 1/4 1/4 1/3 1/3 1/2 RPM 1100 1100 1100 1120 1120 1090 Nominal total CFM 2400 2400 2400 3200 3200 3200 DIRECT DRIVE EVAP FAN DATA Fan Size(Inch) 10 x 8 10 x 8 11 x 10 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Motor HP 1/2 3/4 3/4 3/4 1 1 RPM Variable Variable Variable Variable Variable Variable Frame size 48 48 48 48 48 48 FILTERS Quantity-Size 1 -20x20x1 11 -20x20x1I 1 -20x20x1 I2-20x12x1I 2-20x12x1 I 2-20x12x1 1 1. 208/230 volt single phase only. I .w_._.._ -.._- 7 Johnson Controls Unitary Products 718444-YTG-H-0414 DNZ Two Stage Physical Data Models Component DNZ024 DNZ030 DNZ036 DNZ042 DNZ048 DNZ060 Nominal Tonnage 2.0 2.5 3.0 3.5 4.0 5.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point 24.7 30.8 35.6 43.0 48.8 59.5 (MBH) AHRI net capacity(MBH) 24.0 30.0 34.2 41.5 46.0 56.0 EER 11.6 11.5 11.1 11.6 11.00 11.00 SEER 13.2 13.2 13.2 13.4 13.0 13.0 Nominal CFM 850 940 1200 1300 1550 1600 System power(KW) 2.1 2.7 3.2 3.6 4.2 5.1 Refrigerant type R-410A R-410A R-410A R-410A R410A R410A Refrigerant charge(Ib-oz) 3-10 4-0 4-0 4-14 4-8 5-2 AHRI HEATING PERFORMANCE Heating model D056 D056 D056 D072 D090 D090 D110 D090 D110 Heat input(K Btu) 70/45.5 70/45.5 70/45.5 90/58.5 108/70.2 108/70.2 135/87.8 108/70.2 135/87.8 Heat output(K Btu) 56/36.4 56/36.4 56/36.4 72/46.8 87/56.2 87/56.2 108/70.2 87/56.2 108/70.2 AFUE1 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Steady state efficiency(%) 80 80 80 80 80 80 80 80 80 No.burners 3 3 3 4 4 4 5 4 5 No.stages 2 2 2 2 2 2 2 2 2 Temperature Rise Range(°F) 30-60 30-60 25-55 30-60 45-75 35-65 45-75 35-65 45-75 Gas Limit Setting(°F) 160 160 160 160 175 175 170 175 170 Gas piping connection(in.) 1/2 1/2 1/2 1/2 1/2 1/2 DIMENSIONS(inches) Length 491/8 491/8 491/8 491/8 491/8 491/8 Width 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 Height 331/2 331/2 331/2 411/2 411/2 411/2 OPERATING WT.(lbs.) Unit Weight(lbs.) 378 398 402 460 465 480 COMPRESSOR Type Recip 1-spd I Recip 1-spd I Recip 1-spd I Recip 1-spd I Scroll 1-spd I Scroll 1-spd CONDENSER COIL DATA Face area(Sq.Ft.) 11.9 11.9 11.9 15 15 15 Rows 1 1 1 1 1 1 Fins per inch 23 23 23 23 23 23 Tube diameter(in.) 0.71/18 0.71/18 0.71/18 0.71/18 0.71/18 0.71/18 Circuitry Type 2-pass Micro-Channel EVAPORATOR COIL DATA Face area(Sq.Ft.) 3.4 3.4 3.4 4.4 4.4 4.4 Rows 2 3 3 3 3 4 Fins per inch 15 13 13 16 16 13 Tube diameter 3/8 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced Refrigerant control Orifice Orifice Orifice Orifice TXV TXV CONDENSER FAN DATA Fan diameter(Inch) 22 22 22 22 22 22 Type Prop Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct Direct No.speeds 1 1 1 1 1 1 Motor HP 1/4 1/4 1/4 1/3 1/3 1/2 RPM 1100 1100 1100 1100 1100 1090 Nominal total CFM 2400 2400 2400 3200 3200 3200 DIRECT DRIVE EVAP FAN DATA Fan Size(Inch) 10x8 10x8 11x10 11x10 11 x10 11 x10 , Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Motor HP 1/2 3/4 3/4 3/4 1 1 RPM Variable Variable Variable Variable Variable Variable Frame size 48 48 48 48 48 48 FILTERS Quantity-Size 1 -20x20x1 11 -20x20x1 11-20x20x1 12-20x12x1 12-20x1251 12-20x12x1 1. 208/230 volt single phase only. I8 Johnson Controls Unitary Products 718444-YTG-H-0414 DNQ Single Stage Physical Data Component Models DNQ024 DNQ030 DNQ036 DNQ042 DNQ048 DNQ060 Nominal Tonnage 2.0 2.5 3.0 3.5 4.0 5.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point 24.0 29.8 35.7 41.5 49.6 56.8* (MBH) AHRI net capacity(MBH) 23.6 29.0 34.4 40.0 48.0 55.0* EER 12.0 12.0 12.0 12.0 12.0 12.0* SEER 14.0 14.0 14.0 14.0 14.0 14.0* Nominal CFM 800 900 1100 1400 1500 1550 System power(KW) 2.0 2.4 2.9 3.3 4.0 4.6 Refrigerant type R-410A R-410A R-410A R410A R-410A R-410A Refrigerant charge(lb-oz) 3-8 3-2 3-10 4-9 4-6 5-15 AHRI HEATING PERFORMANCE Heating model N036 N056 N036 N056 N036 N056 N072 N065 N090 N065 N090 N110 N065 N090 N110 Heat input(K Btu) 45 70 45 70 45 70 90 80 108 80 108 135 80 108 135 Heat output(K Btu) 36 56 36 56 36 56 72 64 87 64 87 107 64 87 107 AFDC' 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 Steady state efficiency(%) 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 No.burners 2 3 2 3 2 3 4 3 4 3 4 5 3 4 5 No.stages 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Temperature Rise Range(°F) 25-55 30-60 25-55 30-60 25-55 25-55 30-60 25-55 45-75 25-55 35-65 45-75 25-55 35-65 45-75 Max.Outlet Air Temp.(°F) 165 175 165 175 165 175 175 175 175 175 175 175 175 175 175 Gas Limit Setting(°F) 140 160 140 160 140 160 160 140 160 150 175 160 150 175 160 Gas piping connection(in.) 1/2 1/2 1/2 1/2 1/2 1/2 DIMENSIONS(inches) Length 491/8 491/8 491/8 491/8 491/8 491/8 Width 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 Height 331/2 331/2 331/2 411/2 411/2 41 1/2 OPERATING WT.(lbs.) Unit Weight(lbs.) 390 425 430 485 490 I 530 COMPRESSOR Type Recip 1-spd I Scroll 1-spd Scroll 1-spd Scroll 1-spd Scroll 1-spd Scroll 1-spd CONDENSER COIL DATA Face area(Sq.Ft.) 7.9 11.9 11.9 15 15 15 Rows 1 1 1 1 1 1 Fins per inch 23 23 23 23 23 23 Tube diameter(in.) 0.71/18 0.71 /18 0.71/18 0.71 /18 0.71/18 0.98/25 Circuitry Type 2-pass Micro-Channel EVAPORATOR COIL DATA Face area(Sq.Ft.) 3.4 3.4 3.4 4.4 4.4 4.4 Rows 2 3 3 3 3 4 Fins per inch 15 13 13 16 16 13 Tube diameter 3/8 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced Refrigerant control TXV TXV TXV TXV TXV TXV CONDENSER FAN DATA Fan diameter(Inch) 22 22 22 22 22 22 Type Prop Prop Prop Prop Prop Prop - Drive type Direct _ Direct Direct Direct Direct Direct No.speeds 1 1 1 1 1 1 Motor HP 1/4 1/4 1/4 1/3 1/3 1/3 RPM 1100 1100 1100 1100 1100 1100 Nominal total CFM 2400 2400 2400 3200 3200 3200 DIRECT DRIVE EVAP FAN DATA Fan Size(Inch) 10x8 10x8 11x10 12x11 12x11 12x11 Type Centrifugal Centrifugal Centrifugal Centrifugal . Centrifugal Centrifugal Motor HP 1/2 3/4 3/4 3/4 1 1 RPM Variable Variable Variable Variable Variable Variable Frame size 48 48 48 48 48 48 FILTERS Quantity-Size 1-20x20x1 I1 -20x20x1I 1 -20x20x1 12-20x12x1I 2-20x12x1 I 2-20x12x1 1. 208/230 volt single phase only. I Johnson Controls Unitary Products 9 i iUlitiiitlfiH4iiiii44nt311kiri.iiiliil!ii.031ilMiifIttliiei .A k1.31 r. t itli f.,..,teef{i{HiditiiHieu“MittYl/MAi1,41.1 r«.,yA.w ..44-- - yr4,., i i41 . ,u:su.e us.. 7,1 8444-YTG-H-0414 DNQ Two Stage Physical Data Component Models DNQ024 DNQ030 DNQ036 DNQ042 DNQ048 DNQ060 Nominal Tonnage 2.0 2.5 3.0 3.5 4.0 5.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point(MBH) 24.0 29.8 35.7 41.5 49.6 56.8* AHRI net capacity(MBH) 23.6 29.0 34.4 40.0 48.0 55.0* EER 12.0 12.0 12.0 12.0 12.0 12.0* SEER 14.0 14.0 14.0 14.0 14.0 14.0" Nominal CFM 800 900 1100 1400 1500 1550 System power(KW) 2.0 2.4 2.9 3.3 4.0 4.6 Refrigerant type R-410A R-410A R-410A R410A R-410A R-410A Refrigerant charge(lb-oz) 3-8 3-2 3-10 4-9 4-6 5-15 AHRI HEATING PERFORMANCE Heating model D056 D056 D056 D072 D090 D090 D110 D090 D110 Heat input(K Btu) 70/45.5 70/45.5 70/45.5 90/58.5 108/70.2 108/70.2 135/87.8 108/70.2 135/87.8 Heat output(K Btu) 56/36.4 56/36.4 56/36.4 - 72/46.8 87/56.2 87/56.2 108/70.2 87/56.2 108/70.2 AFUE' 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 Steady state efficiency(%) 80 80 80 80 80 80 80 80 80 No.burners 3 3 3 4 4 4 5 4 5 No.stages 2 2 2 2 2 2 2 2 2 Temperature Rise Range(°F) 30-60 30-60 25-55 30-60 45-75 35-65 45-75 35-65 45-75 Max.Outlet Air Temp.(°F) 175 175 175 175 175 175 175 175 175 Gas Limit Setting(°F) 160 160 160 160 175 175 170 175 170 Gas piping connection(in.) 1/2 1/2 1/2 1/2 1/2 1/2 DIMENSIONS(inches) Length 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 Width 471/4 471/4 471/4 471/4 471/4 471/4 Height 331/2 331/2 331/2 411/2 411/2 411/2 OPERATING WT.(lbs.) Unit Weight(lbs.) 390 I 425 430 485 490 530 COMPRESSOR Type Recip 1-spd I Scroll 1-spd Scroll 1-spd I Scroll 1-spd I Scroll 1-spd Scroll 1-spd CONDENSER COIL DATA Face area(Sq.Ft.) 7.9 11.9 11.9 15 15 15 Rows 1 1 1 1 1 1 Fins per inch 23 23 23 23 23 23 Tube diameter(in.) 0.71 /18 0.71/18 0.71/18 0.71/18 0.71/18 0.98/25 Circuitry Type 2-pass Micro-Channel EVAPORATOR COIL DATA Face area(Sq.Ft.) 3.4 3.4 3.4 4.4 4.4 4.4 Rows 2 3 3 3 3 - 4 Fins per inch 15 13 13 16 16 13 Tube diameter 3/8 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced Refrigerant control TXV TXV TXV TXV TXV TXV CONDENSER FAN DATA Fan diameter(Inch) 22 22 22 22 22 22 Type Prop Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct Direct No.speeds 1 1 1 1 1 1 Motor HP 1/4 1/4 1/4 1/3 1/3 1/3 RPM 1100 1100 1100 1100 1100 1100 Nominal total CFM 2400 2400 2400 3200 3200 3200 DIRECT DRIVE EVAP FAN DATA FanSize(Inch) 10x8 10x8 11x10 12x11 12x11 12x11 Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Motor HP 1/2 3/4 3/4 3/4 1 1 RPM Variable Variable Variable Variable Variable Variable Frame size 48 48 48 48 48 48 FILTERS Quantity-Size 1-20x20x1 11 -20x20x1 11-20x20x1 12-20x12x1 I 2-20x12x1 I 2-20x12x1 1. 208/230 volt single phase only. I 10 Johnson Controls Unitary Products • 718444-YTG-H-0414 • DNX Single Stage Gas Heat Models Component DNX024 DNX036 DNX048 Nominal Tonnage 2.0 3.0 4.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point(MBH) 24.6 38.4 50.0 AHRI net capacity(MBH) 24.0 37.0 48.0 EER 11.5 12.3 11.2 SEER 15.0 16.5 15.0 Nominal CFM 800 1275 1550 System power(KW) 2.1 3.0 4.3 Refrigerant type R-410A R-410A R-410A Refrigerant charge(lb-oz) 7-8 9-12 9-8 AHRI HEATING PERFORMANCE Heating model N036 N056 N065 N090 N065 N090 N110 Heat input(K Btu) 45 70 80 108 80 108 135 Heat output(K Btu) 36 56 64 87 64 87 108 AFUE1 81.0 81.0 81.0 81.0 81.0 81.0 81.0 Steady state efficiency(%) 80 80 80 80 80 80 80 No.burners 2 3 3 4 3 4 5 No.stages 1 1 1 1 1 1 1 Temperature Rise Range(°F) 25-55 30-60 25-55 45-75 25-55 35-65 45-75 Max.Outlet Air Temp.(°F) 165 175 165 175 165 175 175 Gas Limit Setting(°F) 140 160 140 160 150 170 160 Gas piping connection(in.) 1/2 1/2 1/2 DIMENSIONS(inches) Length 49 1/8 49 1/8 49 1/8 Width 47 1/4 47 1/4 47 1/4 Height 331/2 411/2 411/2 OPERATING WT.(lbs.) Unit Weight(lbs.) 440 480 I 500 COMPRESSOR Type Scroll 2-spd Scroll 2-spd Scroll 2-spd CONDENSER COIL DATA Face area(Sq.Ft.) 11.7 14.7 14.7 Rows 2 2 2 Fins per inch 20 20 20 Tube diameter(in.) 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced EVAPORATOR COIL DATA Face area(Sq.Ft.) 3.4 4.4 4.4 Rows 2 3 3 Fins per inch 15 16 16 r Tube diameter 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Refrigerant control TXV TXV TXV CONDENSER FAN DATA Fan diameter(Inch) 22 22 22 Type Prop Prop Prop Drive type Direct Direct Direct No.speeds 1 2 2 Motor HP 1/4 1/3 1/3 RPM 1100 900/1100 900/1100 Nominal total CFM 2400 2400 3000 DIRECT DRIVE EVAP FAN DATA Fan Size(Inch) 10 x 8 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor HP 1/2 1 1 RPM Variable Variable Variable Frame size 48 48 48 FILTERS Quantity-Size 1 -20 x 20 x 1 ( 2-20 x 12 x 1 I 2-20 x 12 x 1 1. 208/230 volt single phase only. Johnson Controls Unitary Products 11 718444-YTG-H-0414 i DNX Two Stage Gas Heat Models Component DNX024 DNX036 DNX048 Nominal Tonnage 2.0 3.0 4.0 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point(MBH) 24.6 38.4 50.0 AHRI net capacity(MBH) 24.0 37.0 48.0 EER 11.5 12.3 11.2 SEER 15.0 16.5 15.0 Nominal CFM 800 1275 1550 System power(KW) 2.1 3.0 4.3 Refrigerant type R-410A R-410A R-410A Refrigerant charge(lb-oz) 7-8 9-12 9-8 AHRI HEATING PERFORMANCE Heating model D056 D090 D090 D110 Heat input(K Btu) 70/45.5 108/70.2 108/70.2 135/87.8 Heat output(K Btu) 56/36.4 87/56.2 87/56.2 108/70.2 AFUEI 81.0 81.0 81.0 81.0 Steady state efficiency(%) 80 80 80 80 No.burners 3 4 4 5 No.stages 2 2 2 2 Temperature Rise Range(°F) 30-60 45-75 35-65 45-75 Max.Outlet Air Temp(°F) 175 175 175 175 Gas Limit Setting(°F) 160 175 170 160 Gas piping connection(in.) 1/2 1/2 1/2 DIMENSIONS(inches) Length 491/8 491/8 491/8 Width 471/4 471/4 471/4 Height 331/2 411/2 411/2 OPERATING WT.(lbs.) Unit Weight(lbs.) 440 480 500 COMPRESSOR Type Scroll 2-spd Scroll 2-spd Scroll 2-spd CONDENSER COIL DATA Face area(Sq.Ft.) 11.7 14.7 14.7 Rows 2 2 2 Fins per inch 20 20 20 Tube diameter(in.) 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced EVAPORATOR COIL DATA Face area(Sq.Ft.) 3.4 4.4 4.4 Rows 2 3 3 Fins per inch 15 16 16 Tube diameter 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Refrigerant control TXV TXV TXV CONDENSER FAN DATA Fan diameter(Inch) 22 22 22 Type Prop Prop Prop Drive type Direct Direct Direct No.speeds 1 2 1 Motor HP 1/4 1/3 1/3 RPM 1100 900/1100 900/1100 jr Nominal total CFM 2400 2400 3000 DIRECT DRIVE EVAP FAN DATA Fan Size(Inch) 10 x 8 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Motor HP 1/2 1 1 RPM Variable Variable Variable Frame size 48 48 48 FILTERS I Quantity-Size 1 -20x20x1 2-20x12x1 12-20x12x1 1. 208/230 volt single phase only. 12 Johnson Controls Unitary Products z, 718444-YTG-H-0414 DNZ Unit Limitations Model Unit Limitations (Tons) Unit Voltage Applied Voltage Outdoor DB Temp Min Max Max(°F) DNZ024 208/230-1-60 187 252 125 (2.0) DNZ030 208/230-1-60 187 252 125 (2.5) 208/230-3-60 187 252 125 460-3-60 432 504 125 DNZ036 208/230-1-60 187 252 125 (3.0) 208/230-3-60 187 252 125 460-3-60 432 504 125 DNZ042 208/230-1-60 187 252 125 (3.5) 208/230-3-60 187 252 125 460-3-60 432 504 125 DNZ048 208/230-1-60 187 252 115 (4.0) 208/230-3-60 187 252 115 460-3-60 432 504 115 DNZ060 208/230-1-60 187 252 115 (5.0) 208/230-3-60 187 252 115 460-3-60 432 504 115 DNQ Unit Limitations Unit Limitations Model Unit Voltage Applied Voltage Outdoor DB Temp (Tons) Min Max Max(°F) DNQ024 208/230-1-60 187 252 125 (2.0) 208/230-1-60 187 252 115 DNQ030 208/230-3-60 187 252 115 (2.5) 460-3-60 432 504 115 208/230-1-60 187 252 115 DNQ036 208/230-3-60 187 252 115 (3.0) 460-3-60 432 504 115 208/230-1-60 187 252 125 DNQ042 208/230-3-60 187 252 125 (3.5) 460-3-60 432 504 125 • 208/230-1-60 187 252 115 DNQ048 208/230-3-60 187 252 115 (4.0) 460-3-60 432 504 115 208/230-1-60 187 252 125 DNQ060 • 208/230-3-60 187 252 125 (5.0) 460-3-60 432 504 125 DNX Unit Limitations Unit Limitations Model Unit Voltage Applied Voltage Outdoor DB Temp (Tons) Min Max Max(°F) DNX024 1 208/230-1-60 187 252 115 (2.0) f 208/230-1-60 187 252 115 DNX036 208/230-3-60 187 252 115 1 (3.0) 460-3-60 432 504 115 208/230 1-60 187 252 115 DNX048 208/230-3-60 187 252 115 (4.0) 460-3-60 432 504 115 l Johnson Controls Unitary Products 13 718444-YTG-H-0414 Capacity Performance DNZ024-060 Cooling Capacities DNZ024(2.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 1 65 75°F 85°F 77 29.9 1.6 4.7 4.0 2.1 - - - 26.9 1.8 9.1 7.4 5.3 - - - 500 72 28.3 1.6 11.7 9.7 7.7 5.8 - - 25.4 1.8 13.6 11.6 9.5 7.5 - - 67 26.6 1.6 17.9 15.4 13.4 11.4 9.5 - 23.8 1.7 18.0 15.7 13.7 11.7 9.7 - 62 25.0 1.6 23.8 16.8 12.3 10.3 8.3 6.3 21.7 1.7 21.1 17.6 14.8 12.8 10.8 8.7 77 30.2 1.6 7.8 5.5 3.2 - - - 27.7 1.8 10.9 8.6 6.2 - - - 72 28.5 1.6 14.7 12.4 10.1 7.9 - - 26.1 1.8 15.8 13.5 11.2 8.8 - - 600 67 26.9 1.6 21.6 19.3 17.0 14.8 12.5 - 24.6 1.8 20.7 18.4 16.1 13.7 11.4 - 62 25.3 1.6 24.5 19.9 16.0 13.8 11.5 9.2 22.4 1.7 22.0 19.7 17.4 15.0 12.7 10.4 57 26.4 1.6 26.4 22.0 18.2 15.9 13.7 11.4 23.7 1.7 23.7 21.5 19.2 16.8 14.5 12.2 77 30.5 1.6 10.8 7.0 4.4 - - - 28.5 1.8 12.6 9.8 7.2 - - - 72 28.8 1.6 17.6 15.1 12.5 10.0 - - 26.9 1.8 18.0 15.4 12.8 10.2 - - 700 67 27.2 1.6 25.2 23.2 20.7 18.1 15.6 - 25.3 1.8 23.3 21.0 18.4 15.8 13.2 - 62 25.6 1.6 25.2 22.9 19.8 17.2 14.7 12.1 23.1 1.7 22.9 21.7 19.9 17.3 14.7 12.1 57 26.7 1.6 26.7 24.5 22.4 19.8 17.3 14.7 24.4 1.7 24.4 23.3 21.9 19.3 16.7 14.1 77 30.8 1.6 13.8 8.4 5.6 - - - 29.3 1.8 14.4 11.0 8.1 - - - 72 29.1 1.6 20.6 17.8 14.9 12.1 - - 27.7 1.8 20.2 17.3 14.4 11.5 - - 800 67 27.4 1.6 27.4 27.1 24.3 21.5 18.6 - 26.0 1.8 26.0 23.6 20.8 17.9 15.0 - 62 25.9 1.6 25.9 25.9 23.5 20.7 17.9 15.0 23.7 1.7 23.7 23.7 22.4 19.5 16.6 13.7 57 27.0 1.6 27.0 27.0 26.6 23.7 20.9 18.1 25.1 1.8 25.1 25.1 24.7 21.8 19.0 16.1 72 30.0 1.6 20.4 17.1 13.8 10.5 - - 28.0 1.8 20.9 17.7 14.4 11.2 - - 900 67 28.2 1.6 28.2 26.2 22.9 19.5 16.2 - 26.4 1.8 26.4 24.0 20.8 17.5 14.2 - 62 26.6 1.6 26.6 26.6 23.5 20.2 16.9 13.6 24.0 1.7 24.0 24.0 22.4 19.2 15.9 12.7 57 27.8 1.6 27.8 27.8 26.5 23.2 19.9 16.6 25.4 1.8 25.4 25.4 24.7 21.5 18.2 15.0 72 30.8 1.6 20.1 16.4 12.6 8.8 - - 28.4 1.8 21.6 18.0 14.4 10.8 - - 1000 67 29.0 1.6 29.0 25.2 21.4 17.6 13.9 - 26.7 1.8 26.7 24.4 20.8 17.1 13.5 - 62 27.3 1.6 27.3 27.3 23.4 19.6 15.9 12.1 24.4 1.7 24.4 24.4 22.4 18.8 15.2 11.6 57 28.5 1.6 28.5 28.5 26.4 22.7 18.9 15.1 25.8 1.8 25.8 25.8 24.7 21.1 17.5 13.9 • 3 14 Johnson Controls Unitary Products 718444-YTG-H-0414 DNZ024(2.0 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW? 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 80 I 75 I 70 I 65 95°F 105°F 77 23.9 2.0 12.8 10.7 8.6 - - - 22.8 2.1 11.4 9.3 7.4 - - - 500 72 22.5 1.9 15.5 13.4 11.3 9.2 - - 20.8 2.1 14.3 12.2 10.2 8.1 - - 67 21.1 1.9 18.2 16.1 14.0 11.9 9.9 - 18.7 2.0 17.3 15.2 12.9 10.8 8.7 - 62 18.5 1.9 18.5 18.5 17.4 15.3 13.2 11.1 17.0 2.0 17.0 17.0 15.1 13.0 11.0 8.9 77 25.2 2.0 14.0 11.6 9.3 - - - 24.0 2.1 13.5 10.5 8.1 - - - 72 23.7 1.9 16.9 14.5 12.2 9.8 - - 21.8 2.1 16.0 13.5 11.1 8.7 - - 600 67 22.3 1.9 19.8 17.5 15.1 12.7 10.3 - 19.7 2.0 18.4 16.5 14.1 11.7 9.3 - 62 19.5 1.9 19.5 19.5 18.7 16.3 13.9 11.6 17.8 2.0 17.8 17.8 16.6 14.1 11.7 9.3 57 21.0 1.9 21.0 21.0 20.1 17.7 15.4 13.0 19.1 2.0 19.1 19.1 17.7 15.2 12.8 10.4 77 26.5 2.0 15.2 12.6 9.9 - - - 25.1 2.1 15.6 11.8 8.8 - - - 72 24.9 1.9 18.3 15.7 13.0 10.4 - - 22.9 2.1 17.6 14.8 12.1 9.4 - - 700 67 23.4 1.9 21.5 18.8 16.1 13.5 10.8 - 20.6 2.0 19.6 17.9 15.4 12.6 9.9 - 62 20.5 1.9 20.5 20.5 20.0 17.3 14.7 12.0 18.7 2.0 18.7 18.7 18.0 15.2 12.5 9.8 57 22.1 1.9 22.1 22.1 21.5 18.8 16.2 13.5 20.0 2.0 20.0 20.0 19.2 16.4 13.7 10.9 77 27.8 2.0 16.4 13.5 10.6 - - - 26.3 2.1 17.7 13.0 9.5 - - - 72 26.2 1.9 19.8 16.8 13.9 10.9 - - 23.9 2.1 19.2 16.2 13.1 10.0 - - 800 67 24.6 1.9 23.1 20.1 17.2 14.3 11.3 - 21.5 2.1 20.8 19.3 16.6 13.5 10.5 - 62 21.5 1.9 21.5 21.5 21.3 18.4 15.4 12.5 19.5 2.0 19.5 19.5 19.4 16.4 13.3 10.2 57 23.2 1.9 23.2 23.2 22.9 20.0 17.0 14.1 21.0 2.0 21.0 21.0 20.7 17.6 14.5 11.5 72 26.1 2.0 21.5 18.3 15.0 11.8 - - 24.0 2.1 20.7 17.4 14.0 10.7 - - 900 67 24.5 1.9 23.8 21.9 18.7 15.4 12.2 - 21.7 2.1 21.3 20.3 17.8 14.5 11.2 - 62 21.5 1.9 21.5 21.5 21.4 18.2 14.9 11.7 19.7 2.0 19.7 19.7 19.6 16.3 12.9 9.6 57 23.1 1.9 23.1 23.1 23.0 19.8 16.6 13.4 21.1 2.1 21.1 21.1 21.0 17.6 14.3 11.0 72 26.1 2.0 23.2 19.7 16.2 12.8 - - 24.2 2.1 22.2 18.6 15.0 11.4 - - 1000 67 24.5 1.9 24.5 23.6 20.1 16.6 13.2 - 21.8 2.1 21.8 21.3 19.1 15.5 11.9 - 62 21.4 1.9 21.4 21.4 21.4 18.0 14.5 11.0 19.8 2.1 19.8 19.8 19.8 16.2 12.6 9.0 57 23.1 1.9 23.1 23.1 23.1 19.6 16.1 12.7 21.2 2.1 21.2 21.2 21.2 17.6 14.0 10.4 Johnson Controls Unitary Products 15 7.18444-YTG-H-0414 DNZ024(2.0 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW? 90 I 85 I 80 I 75 I 70 I 65 ' (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 115°F 125°F 77 21.8 2.3 10.0 7.9 6.2 - - - 20.8 2.4 10.0 5.9 5.1 - - - 72 19.1 2.2 13.2 11.1 9.0 6.9 - - 17.4 2.4 12.0 9.9 7.8 5.8 - - 500 67 16.3 2.2 16.3 14.2 11.8 9.7 7.6 - 14.0 2.3 14.0 14.0 10.6 8.5 6.5 - 62 15.5 2.2 15.5 15.5 12.9 10.8 8.7 6.6 14.0 2.3 14.0 14.0 10.6 8.5 6.5 4.4 77 22.8 2.3 13.0 9.5 7.0 - - - 21.6 2.4 13.7 8.6 5.9 - - - 72 19.9 2.2 15.0 12.5 10.1 7.6 - - 18.0 2.4 14.1 11.6 9.1 6.5 - - 600 67 17.1 2.2 17.1 15.6 13.2 10.7 8.3 - 14.5 2.3 14.5 14.5 12.2 9.7 7.2 - 62 16.2 2.2 16.2 16.2 14.4 12.0 9.5 7.1 14.6 2.3 14.6 14.6 12.3 9.8 7.3 4.8 57 17.3 2.2 17.3 17.3 15.2 12.8 10.3 7.8 15.5 2.3 15.5 15.5 12.8 10.3 7.8 5.3 77 23.8 2.3 15.9 11.0 7.8 - - - 22.4 2.5 17.3 11.4 6.7 - - - 72 20.8 2.2 16.9 14.0 11.2 8.3 - - 18.7 2.4 16.1 13.2 10.3 7.3 - - 700 67 17.8 2.2 17.8 17.1 14.6 11.8 8.9 - 15.0 2.3 15.0 15.0 13.8 10.9 8.0 - 62 16.9 2.2 16.9 16.9 16.0 13.2 10.3 7.5 15.1 2.3 15.1 15.1 14.0 11.1 8.2 5.2 57 18.0 2.2 18.0 18.0 16.9 14.0 11.2 8.4 16.0 2.3 16.0 16.0 14.5 11.6 8.7 5.8 77 24.7 2.3 18.9 12.5 8.5 - - - 23.2 2.5 20.9 14.2 7.5 - - - 72 21.6 2.3 18.7 15.5 12.3 9.1 - - 19.3 2.4 18.2 14.8 11.5 8.1 - - 800 67 18.5 2.2 18.5 18.5 16.0 12.8 9.6 - 15.5 2.3 15.5 15.5 15.5 12.1 8.8 - 62 17.6 2.2 17.6 17.6 17.6 14.3 11.1 7.9 15.6 2.3 15.6 15.6 15.6 12.3 9.0 5.6 57 18.8 2.2 18.8 18.8 18.5 15.3 12.1 8.9 16.5 2.4 16.5 16.5 16.3 13.0 9.6 6.3 72 22.0 2.3 20.0 16.5 13.0 9.6 - - 19.9 2.4 19.2 15.6 12.0 8.4 - - 67 18.8 2.2 18.8 18.8 17.0 13.6 10.1 - 15.9 2.4 15.9 15.9 15.9 12.6 9.0 - 900 62 17.8 2.2 17.8 17.8 17.8 14.4 10.9 7.5 16.0 2.3 16.0 16.0 16.0 12.5 8.9 5.3 57 19.1 2.2 19.1 19.1 18.9 15.5 12.0 8.5 17.0 2.4 17.0 17.0 16.9 13.3 9.7 6.1 72 22.3 2.3 21.2 17.5 13.8 10.1 - - 20.4 2.4 20.3 16.4 12.6 8.8 - - 67 19.1 2.2 19.1 19.1 18.0 14.3 10.6 - 16.4 2.4 16.4 16.4 16.4 13.2 9.3 - 1000 62 18.1 2.2 18.1 18.1 18.1 14.4 10.7 7.0 16.5 2.4 16.5 16.5 16.5 12.7 8.8 5.0 57 19.4 2.2 19.4 19.4 19.4 15.7 11.9 8.2 17.5 2.4 17.5 17.5 17.5 13.7 9.9 6.0 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. I tl f, fl f 16 Johnson Controls Unitary Products 718444-YTG-H-0414 . DNZ030(2.5 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) _ Net Total Sensible Capacity(MBh) CFM WB Capacity Input Return Dry Bulb(°F) Capacity Inputt Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 35.3 2.1 15.9 12.6 9.3 - - - 33.9 2.3 16.5 13.1 9.7 - - - 850 72 33.5 2.1 20.8 17.5 14.2 10.8 - - 31.7 2.3 20.8 17.5 14.1 10.7 - - 67 31.6 2.1 25.7 22.4 19.0 15.7 12.4 - 29.6 2.3 25.2 21.8 18.4 15.0 11.6 - 62 29.7 2.0 29.7 27.6 22.8 19.5 16.1 12.8 27.4 2.2 27.4 26.3 22.4 19.0 15.6 12.2 57 37.1 2.1 17.0 13.7 10.4 - - - 35.6 2.4 17.6 14.2 10.7 - - - 77 35.1 2.1 22.4 19.1 15.8 12.4 - - 33.3 2.3 22.4 18.9 15.5 12.0 - - 900 72 33.2 2.1 27.8 24.5 21.2 17.8 14.5 - 31.1 2.3 27.2 23.7 20.3 16.8 13.3 - 67 31.2 2.0 31.2 29.8 25.3 22.0 18.7 15.4 28.8 2.2 28.8 28.1 24.6 21.2 17.7 14.3 62 29.9 2.0 29.9 29.9 27.1 23.8 20.5 17.2 28.0 2.2 28.0 28.0 25.8 22.4 18.9 15.5 57 38.8 2.1 18.0 14.7 11.4 - - - 37.3 2.4 18.8 15.2 11.7 - - - 77 36.8 2.1 24.0 20.7 17.3 14.0 - - 34.9 2.3 24.0 20.4 16.9 13.4 - - 950 72 34.8 2.1 29.9 26.6 23.3 20.0 16.7 - 32.5 2.3 29.1 25.6 22.1 18.6 15.1 - 67 32.7 2.1 32.7 32.0 27.9 24.6 21.3 17.9 30.2 2.3 30.2 29.8 26.9 23.4 19.8 16.3 62 31.3 2.1 31.3 31.3 29.9 26.6 23.2 19.9 29.4 2.3 29.4 29.4 28.2 24.7 21.2 17.6 57 40.6 2.2 19.1 15.8 12.5 - - - 39.0 2.4 19.9 16.3 12.7 - - - 72 38.5 2.1 25.6 22.2 18.9 15.6 - - 36.5 2.3 25.5 21.9 18.3 14.7 - - 1000 67 36.4 2.1 32.0 28.7 25.4 22.1 18.8 - 34.0 2.3 31.1 27.6 24.0 20.4 16.8 - 62 34.2 2.1 34.2 34.2 30.4 27.1 23.8 20.5 31.5 2.3 31.5 31.5 29.1 25.6 22.0 18.4 57 32.8 2.1 32.8 32.8 32.6 29.3 26.0 22.7 30.7 2.3 30.7 30.7 30.6 27.0 23.4 19.8 72 39.1 2.1 26.5 22.9 19.4 15.8 - - 37.1 2.4 26.9 23.0 19.2 15.3 - - 67 37.0 2.1 34.1 29.6 26.0 22.4 18.9 - 34.6 2.3 32.8 28.9 25.1 21.2 17.4 - 1125 62 34.7 2.1 34.7 34.7 32.1 28.6 25.0 21.5 32.0 2.3 32.0 32.0 30.5 26.6 22.8 18.9 57 33.3 2.1 33.3 33.3 33.2 29.7 26.1 22.5 31.2 2.3 31.2 31.2 31.1 27.3 23.4 19.6 72 39.8 2.2 27.4 23.6 19.8 16.0 - - 37.7 2.4 28.2 24.1 20.0 15.9 - - 1250 67 37.6 2.1 36.1 30.4 26.6 22.8 19.0 - 35.1 2.3 34.4 30.3 26.2 22.0 17.9 - 62 35.3 2.1 35.3 35.3 33.8 30.0 26.2 22.4 32.5 2.3 32.5 32.5 31.8 27.7 23.6 19.5 57 33.8 2.1 33.8 33.8 33.8 30.0 26.2 22.4 31.7 2.3 31.7 31.7 31.7 27.6 23.5 19.4 95°F 105°F 77 32.4 2.6 17.1 13.7 10.2 - - - 30.7 2.8 17.4 13.0 9.4 - - - 850 72 30.0 2.5 20.9 17.4 14.0 10.5 - - 27.8 2.7 20.4 16.8 13.1 9.5 - - 67 27.5 2.5 24.7 21.2 17.8 14.3 10.8 - 24.9 2.6 23.5 20.6 16.9 13.2 9.6 - 62 25.1 2.4 25.1 25.1 21.9 18.5 15.0 11.6 23.0 2.6 23.0 23.0 20.1 16.4 12.8 9.1 57 34.1 2.6 18.3 14.7 11.1 - - - 32.1 2.8 18.8 14.0 10.2 - - - 77 31.5 2.5 22.4 18.8 15.2 11.6 29.1 2.7 21.8 18.1 14.3 10.6 900 72 28.9 2.5 26.5 22.9 19.3 15.8 12.2 26.1 2.7 24.9 22.2 18.4 14.7 10.9 - 67 26.4 2.4 26.4 26.4 23.9 20.3 16.7 13.1 24.1 2.6 24.1 24.1 21.9 18.2 14.4 10.7 62 26.2 2.4 26.2 26.2 24.5 20.9 17.3 13.8 24.0 2.6 24.0 24.0 22.2 18.4 14.7 10.9 57 35.7 2.6 19.5 15.8 12.0 - - - 33.4 2.8 20.2 14.9 11.1 - - - 77 33.0 2.5 23.9 20.2 16.5 12.8 - - 30.3 2.7 23.2 19.4 15.5 11.7 - - 950 72 30.3 2.5 28.4 24.7 20.9 17.2 13.5 - 27.2 2.7 26.2 23.8 20.0 16.2 12.3 - 67 27.6 2.4 27.6 27.6 25.9 22.1 18.4 14.7 25.1 2.6 25.1 25.1 23.7 19.9 16.1 12.2 62 27.4 2.4 27.4 27.4 26.5 22.8 19.1 15.4 25.0 2.6 25.0 25.0 24.0 20.2 16.3 12.5 57 37.4 2.6 20.7 16.8 12.9 - - - 34.8 2.8 21.6 15.9 11.9 - - - 72 34.6 2.6 25.5 21.6 17.7 13.9 - - 31.6 2.8 24.6 20.7 16.7 12.8 - - 1000 67 31.7 2.5 30.3 26.4 22.5 18.7 14.8 - 28.3 2.7 27.6 25.5 21.5 17.6 13.7 - 62 28.9 2.5 28.9 28.9 27.8 24.0 20.1 16.2 26.1 2.6 26.1 26.1 25.6 21.7 17.7 13.8 57 28.7 2.5 28.7 28.7 28.6 24.7 20.8 17.0 26.0 2.6 26.0 26.0 25.9 21.9 18.0 14.1 72 35.1 2.6 27.3 23.1 19.0 14.8 - - 32.1 2.8 26.4 22.1 17.9 13.6 - - 67 32.2 2.5 31.5 28.3 24.1 20.0 15.8 - 28.8 2.7 28.4 26.7 23.0 18.8 14.5 - 1125 62 29.3 2.5 29.3 29.3 28.8 24.7 20.5 16.4 26.5 2.7 26.5 26.5 26.3 22.0 17.8 13.5 57 29.1 2.5 29.1 29.1 29.1 24.9 20.8 16.6 26.5 2.7 26.5 26.5 26.4 22.1 17.9 13.6 72 35.6 2.6 29.1 24.7 20.2 15.8 - - 32.6 2.8 28.2 23.6 19.0 14.5 - - 1250 67 32.7 2.5 32.7 30.1 25.7 21.3 16.9 - 29.2 2.7 29.2 28.0 24.5 19.9 15.4 - 62 29.8 2.5 29.8 29.8 29.8 25.4 21.0 16.5 27.0 2.7 27.0 27.0 27.0 22.4 17.8 13.2 57 29.6 2.5 29.6 29.6 29.6 25.2 20.7 16.3 26.9 2.7 26.9 26.9 26.9 22.3 17.7 13.1 Johnson Controls Unitary Products 17 7.18444-YTG-H-0414 , DNZ030(2.5 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 115°F 125°F 77 29.0 3.0 17.6 12.4 8.5 - - - 27.2 3.3 19.3 11.2 7.7 - - - 850 72 25.7 2.9 20.0 16.1 12.3 8.4 - - 23.5 3.1 19.6 15.5 11.4 7.4 - - 67 22.4 2.8 22.4 19.9 16.0 12.2 8.3 - 19.8 3.0 19.8 19.8 15.2 11.1 7.1 - 62 21.0 2.8 21.0 21.0 18.2 14.3 10.5 6.6 18.9 3.0 18.9 18.9 16.3 12.3 8.2 4.1 57 30.0 3.0 19.3 13.2 9.3 - - - 28.0 3.3 21.0 12.8 8.4 - - - 77 26.6 2.9 21.2 17.3 13.4 9.5 - - 24.2 3.1 20.7 16.6 12.5 8.5 - - 900 72 23.2 2.8 23.2 21.5 17.6 13.6 9.7 - 20.4 3.0 20.4 20.4 16.7 12.6 8.5 - 67 21.8 2.8 21.8 21.8 19.9 16.0 12.1 8.2 19.5 3.0 19.5 19.5 17.9 13.8 9.8 5.7 62 21.8 2.8 21.8 21.8 19.8 15.9 12.0 8.1 19.6 3.0 19.6 19.6 17.4 13.3 9.3 5.2 57 31.1 3.0 20.9 14.1 10.1 - - - 28.8 3.3 22.6 14.5 9.1 - - - 77 27.6 2.9 22.5 18.5 14.6 10.6 - - 24.9 3.2 21.8 17.7 13.6 9.6 - - I 950 72 24.1 2.9 24.1 23.0 19.1 15.1 11.2 - 20.9 3.0 20.9 20.9 18.1 14.1 10.0 - 67 22.5 2.8 22.5 22.5 21.6 17.7 13.7 9.8 20.0 3.0 20.0 20.0 19.5 15.4 11.4 7.3 62 22.6 2.8 22.6 22.6 21.5 17.5 13.6 9.6 20.1 3.0 20.1 20.1 18.9 14.9 10.8 6.7 57 32.2 3.1 22.6 14.9 10.9 - - - 29.6 3.3 24.2 16.1 9.9 - - - 72 28.6 3.0 23.7 19.7 15.7 11.7 - - 25.5 3.2 22.9 18.8 14.7 10.7 - - 1000 67 24.9 2.9 24.9 24.6 20.6 16.6 12.6 - 21.5 3.0 21.5 21.5 19.6 15.5 11.5 - 62 23.3 2.8 23.3 23.3 23.3 19.3 15.3 11.3 20.5 3.0 20.5 20.5 20.5 17.0 12.9 8.9 57 23.4 2.8 23.4 23.4 23.2 19.2 15.2 11.2 20.7 3.0 20.7 20.7 20.5 16.4 12.4 8.3 72 29.1 3.0 25.5 21.2 16.8 12.4 - - 26.1 3.2 24.7 20.2 15.7 11.2 - - 67 25.3 2.9 25.3 25.2 21.9 17.6 13.2 - 21.9 3.1 21.9 21.9 20.9 16.4 11.9 - 1125 62 23.7 2.8 23.7 23.7 23.7 19.4 15.0 10.6 21.0 3.0 21.0 21.0 21.0 16.7 12.2 7.7 57 23.8 2.9 23.8 23.8 23.7 19.3 14.9 10.6 21.1 3.0 21.1 21.1 21.0 16.5 12.0 7.5 72 29.6 3.0 27.4 22.6 17.8 13.1 - - 26.6 3.2 26.5 21.6 16.6 11.7 - - 1250 67 25.8 2.9 25.8 25.8 23.3 18.6 13.8 - 22.4 3.1 22.4 22.4 22.1 17.2 12.3 - 62 24.2 2.9 24.2 24.2 24.2 19.4 14.7 9.9 21.4 3.1 21.4 21.4 21.4 16.4 11.5 6.6 57 24.2 2.9 24.2 24.2 24.2 19.5 14.7 9.9 21.5 3.1 21.5 21.5 21.5 16.6 11.7 6.7 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 18 Johnson Controls Unitary Products • 718444-YTG-H-0414 DNZ036(3.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 36.9 1.9 18.9 15.2 12.1 - - - 40.3 2.5 18.3 15.2 12.1 - - - 750 72 34.7 2.0 22.9 19.8 16.7 13.6 - - 37.1 2.5 23.2 20.0 16.8 13.7 - - 67 32.6 2.1 26.9 24.4 21.3 18.2 15.1 - 33.9 2.5 28.1 24.8 21.6 18.4 15.2 - 62 30.7 2.0 30.7 30.7 26.4 23.3 20.2 17.1 31.3 2.5 31.3 30.7 25.7 22.5 19.3 16.2 77 39.2 1.9 20.6 17.0 13.4 - - - 41.4 2.4 20.5 16.8 13.2 - - - 72 36.8 2.0 25.6 22.0 18.5 14.9 - - 38.1 2.5 25.7 22.1 18.4 14.7 - - 900 67 34.5 2.2 30.7 27.1 23.5 19.9 16.3 - 34.8 2.5 30.9 27.3 23.6 19.9 16.2 - 62 32.4 2.0 32.4 32.4 29.2 25.6 22.0 18.4 32.1 2.5 32.1 31.7 28.0 24.4 20.7 17.0 57 32.7 2.1 32.7 32.7 29.7 26.1 22.5 19.0 32.7 2.5 32.7 32.3 28.7 25.0 21.3 17.6 li 77 41.4 2.0 22.2 18.8 14.7 - - - 42.4 2.4 22.8 18.5 14.3 - - - 72 38.9 2.1 28.4 24.3 20.2 16.1 - - 39.1 2.5 28.3 24.1 19.9 15.7 - - 1050 67 36.4 2.2 34.5 29.8 25.7 21.7 17.6 - 35.7 2.5 33.7 29.7 25.6 21.4 17.2 - 62 34.2 2.1 34.2 34.2 31.9 27.8 23.7 19.7 32.9 2.5 32.9 32.7 30.4 26.2 22.0 17.9 57 34.5 2.1 34.5 34.5 32.5 28.4 24.4 20.3 33.5 2.5 33.5 33.3 31.1 26.9 22.7 18.5 77 43.7 2.0 23.8 20.5 15.9 43.5 2.4 25.1 20.1 15.4 72 41.0 2.1 31.1 26.5 22.0 17.4 - - 40.0 2.5 30.8 26.1 21.5 16.8 - - 1200 67 38.4 2.2 38.4 32.6 28.0 23.4 18.8 - 36.6 2.5 36.6 32.2 27.5 22.9 18.2 - 62 36.0 2.1 36.0 36.0 34.6 30.1 25.5 20.9 33.8 2.5 33.8 33.8 32.7 28.1 23.4 18.7 57 36.3 2.1 36.3 36.3 35.3 30.7 26.2 21.6 34.3 2.5 34.3 34.3 33.5 28.8 24.1 19.4 72 41.7 2.1 33.3 28.1 22.8 17.6 - - 40.2 2.5 32.5 27.2 22.0 16.7 - - u 1350 67 39.0 2.2 39.0 34.3 29.1 23.9 18.7 - 36.8 2.5 36.8 33.4 28.2 22.9 17.7 - 62 36.5 2.0 36.5 36.5 35.9 30.7 25.4 20.2 33.9 2.5 33.9 33.9 33.4 28.2 22.9 17.7 57 36.9 2.1 36.9 36.9 36.4 31.2 25.9 20.7 34.5 2.5 34.5 34.5 34.1 28.8 23.6 18.3 72 42.4 2.0 35.5 29.6 23.7 17.9 - - 40.5 2.5 34.1 28.3 22.5 16.7 - - 1500 67 39.6 2.1 39.6 36.1 30.2 24.4 18.5 - 37.0 2.5 37.0 34.7 28.9 23.0 17.2 - 62 37.1 2.0 37.1 37.1 37.1 31.3 25.4 19.5 34.1 2.5 34.1 34.1 34.1 28.3 22.5 16.6 57 37.4 2.0 37.4 37.4 37.4 31.6 25.7 19.8 34.7 2.5 34.7 34.7 34.7 28.9 23.1 17.2 95°F 105°F 77 43.7 3.0 17.6 15.2 12.0 40.0 3.3 16.0 14.3 11.1 - 750 72 39.4 2.9 23.5 20.2 16.9 13.7 36.2 3.3 22.5 19.2 15.9 12.7 - 67 35.1 2.9 29.4 25.2 21.9 18.6 15.4 32.5 3.3 29.0 24.1 20.7 17.5 14.2 - 62 31.9 3.0 31.9 30.2 24.9 21.7 18.4 15.2 30.0 3.4 30.0 28.9 23.4 20.1 16.8 13.6 77 43.6 3.0 20.5 16.7 12.9 - - 39.7 3.3 19.5 15.7 12.0 - _ 72 39.3 2.9 25.8 22.1 18.3 14.5 36.0 3.3 24.7 20.9 17.2 13.4 900 67 35.0 2.8 31.2 27.4 23.6 19.9 16.1 32.2 3.3 29.9 26.2 22.4 18.6 14.9 62 31.8 3.0 31.8 30.7 26.9 23.1 19.4 15.6 29.8 3.4 29.8 29.0 25.3 21.5 17.7 14.0 57 32.6 3.0 32.6 31.4 27.6 23.9 20.1 16.3 30.6 3.4 30.6 29.5 25.8 22.0 18.3 14.5 77 43.4 2.9 23.4 18.2 13.9 39.4 3.3 23.0 17.2 12.9 - - - 72 39.2 2.9 28.2 23.9 19.6 15.3 - - 35.7 3.3 26.9 22.7 18.5 14.2 - - 1050 67 34.9 2.8 33.0 29.6 25.4 21.1 16.8 - 32.0 3.3 30.8 28.2 24.0 19.8 15.6 - 62 31.6 3.0 31.6 31.1 28.9 24.6 20.3 16.1 29.5 3.4 29.5 29.2 27.1 22.9 18.6 14.4 57 32.5 2.9 32.5 31.9 29.6 25.4 21.1 16.8 30.4 3.4 30.4 29.8 27.7 23.4 19.2 15.0 77 43.3 2.9 26.3 19.6 14.8 39.1 3.3 26.6 18.6 13.8 - 72 39.0 2.8 30.5 25.7 21.0 16.2 - - 35.4 3.3 29.2 24.4 19.7 15.0 - - 1200 67 34.8 2.7 34.8 31.9 27.1 22.3 17.5 - 31.8 3.3 31.8 30.3 25.7 21.0 16.3 - 62 31.5 2.9 31.5 31.5 30.8 26.1 21.3 16.5 29.3 3.4 29.3 29.3 29.0 24.3 19.5 14.8 57 32.4 2.9 32.4 32.4 31.7 26.9 22.1 17.3 30.1 3.4 30.1 30.1 29.6 24.8 20.1 15.4 72 38.8 2.9 31.7 26.4 21.1 15.8 - - 35.3 3.3 30.5 25.3 20.0 14.8 - - 67 34.5 2.8 34.5 32.6 27.3 22.0 16.7 - 31.6 3.3 31.6 30.7 26.1 20.8 15.6 - 1350 62 31.3 3.0 31.3 31.3 31.0 25.7 20.4 15.1 29.2 3.4 29.2 29.2 29.1 23.8 18.6 13.3 57 32.2 2.9 32.2 32.2 31.8 26.5 21.3 16.0 30.0 3.4 30.0 30.0 29.7 24.5 19.3 14.0 72 38.5 2.9 32.8 27.0 21.3 15.5 - - 35.2 3.3 31.9 26.1 20.3 14.5 - - 67 34.3 2.9 34.3 33.3 27.5 21.7 15.9 - 31.5 3.3 31.5 31.0 26.5 20.7 14.9 - 1500 62 31.1 3.0 31.1 31.1 31.1 25.3 19.6 13.8 29.1 3.5 29.1 29.1 29.1 23.4 17.6 11.8 57 32.0 3.0 32.0 32.0 32.0 26.2 20.4 14.6 29.9 3.4 29.9 29.9 29.9 24.2 18.4 12.6 Johnson Controls Unitary Products 19 it ,, 718444-YTG-H-0414 DNZ036(3.0 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) _ Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 115°F 125°F 77 36.2 3.6 14.4 13.4 10.2 - - - 32.4 3.9 13.9 11.7 9.3 - - - 750 72 33.0 3.7 21.5 18.2 14.9 11.6 - - 29.8 4.1 20.5 17.2 13.9 10.6 - - 67 29.8 3.8 28.6 23.0 19.6 16.3 13.0 - 27.1 4.2 27.1 21.9 18.4 15.1 11.8 - 62 28.1 3.8 28.1 27.5 21.8 18.6 15.3 12.0 26.2 4.3 26.2 26.1 20.3 17.0 13.7 10.4 77 35.8 3.6 18.5 14.8 11.0 - - - 31.9 4.0 18.3 13.8 10.1 - - - 72 32.6 3.7 23.6 19.8 16.1 12.4 - - 29.3 4.1 22.5 18.7 15.0 11.3 - - 900 67 29.4 3.8 28.6 24.9 21.2 17.4 13.7 - 26.6 4.3 26.6 23.7 19.9 16.2 12.5 - 62 27.8 3.9 27.8 27.3 23.6 19.9 16.1 12.4 25.8 4.3 25.8 25.7 21.9 18.2 14.5 10.8 57 28.5 3.8 28.5 27.6 23.9 20.2 16.4 12.7 26.5 4.2 26.5 25.8 22.0 18.3 14.6 10.9 77 35.4 3.7 22.7 16.2 11.9 - - - 31.3 4.1 22.7 15.9 10.9 - - - 72 32.2 3.8 25.7 21.5 17.3 13.1 - - 28.7 4.2 24.4 20.3 16.1 12.0 - - 1050 67 29.1 3.8 28.7 26.8 22.7 18.5 14.3 - 26.2 4.4 26.2 25.4 21.4 17.3 13.1 - 62 27.4 3.9 27.4 27.2 25.4 21.2 17.0 12.8 25.3 4.4 25.3 25.3 23.6 19.4 15.3 11.1 57 28.2 3.8 28.2 27.7 25.7 21.5 17.3 13.1 26.0 4.3 26.0 25.7 23.7 19.5 15.4 11.2 77 34.9 3.7 26.9 17.6 12.7 - - - 30.8 4.1 27.1 18.0 11.6 - - - 72 31.8 3.8 27.8 23.1 18.5 13.8 - - 28.2 4.3 26.4 21.8 17.3 12.7 - - 1200 67 28.7 3.9 28.7 28.7 24.3 19.7 15.0 - 25.7 4.4 25.7 25.7 22.9 18.3 13.8 - 62 27.1 3.9 27.1 27.1 27.1 22.5 17.8 13.2 24.9 4.4 24.9 24.9 24.9 20.7 16.1 11.5 57 27.8 3.9 27.8 27.8 27.5 22.8 18.2 13.5 25.6 4.4 25.6 25.6 25.4 20.8 16.2 11.6 72 31.9 3.8 29.3 24.1 18.9 13.7 - - 28.4 4.2 28.2 23.0 17.8 12.7 - - 67 28.8 3.9 28.8 28.8 24.9 19.7 14.5 - 25.9 4.4 25.9 25.9 23.7 18.5 13.3 - 1350 62 27.1 3.9 27.1 27.1 27.1 21.9 16.7 11.5 25.0 4.4 25.0 25.0 25.0 20.0 14.9 9.7 57 27.9 3.8 27.9 27.9 27.7 22.5 17.3 12.0 25.7 4.3 25.7 25.7 25.6 20.4 15.3 10.1 72 31.9 3.7 30.9 25.1 19.4 13.6 - - 28.6 4.2 28.6 24.2 18.4 12.6 - - 1500 67 28.8 3.8 28.8 28.8 25.4 19.7 13.9 - 26.0 4.3 26.0 26.0 24.4 18.6 12.9 - 62 27.1 3.9 27.1 27.1 27.1 21.4 15.6 9.8 25.2 4.3 25.2 25.2 25.2 19.4 13.6 7.9 57 27.9 3.8 27.9 27.9 27.9 22.1 16.3 10.6 25.8 4.3 25.8 25.8 25.8 20.1 14.3 8.5 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 20 Johnson Controls Unitary Products 718444-YTG-H-0414 DNZ042(3.5 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 46.4 2.7 21.7 16.7 12.9 - - - 45.8 2.9 20.8 16.8 12.9 - - - 875 72 44.6 2.6 27.5 23.6 19.8 15.9 - - 42.9 2.9 27.0 23.1 19.1 15.2 - - 67 42.8 2.6 33.3 30.5 26.7 22.8 18.9 - 39.9 2.9 33.2 29.3 25.4 21.5 17.5 - 62 39.1 2.5 39.1 39.1 32.1 28.2 24.4 20.5 36.5 2.8 36.5 36.5 30.4 26.4 22.5 18.6 57 48.9 2.7 23.1 18.7 14.3 - - - 48.1 3.0 23.4 18.9 14.4 - - - 77 47.0 2.7 30.8 26.4 22.0 17.6 - - 45.0 2.9 30.4 25.9 21.4 16.8 - - 1050 72 45.0 2.6 38.5 34.1 29.7 25.3 20.9 - 41.9 2.9 37.3 32.8 28.3 23.8 19.3 - 67 41.2 2.6 41.2 41.2 35.8 31.4 27.0 22.6 38.4 2.8 38.4 38.4 33.9 29.4 24.8 20.3 62 40.1 2.5 40.1 40.1 36.4 32.0 27.6 23.2 37.5 2.8 37.5 37.5 33.7 29.2 24.7 20.2 57 51.4 2.7 24.5 20.7 15.8 - - - 50.4 3.0 26.1 21.0 15.9 - - - 77 49.3 2.7 34.1 29.2 24.3 19.4 - - 47.2 2.9 33.8 28.7 23.6 18.5 - - 1225 72 47.3 2.6 43.6 37.6 32.7 27.8 22.9 - 43.9 2.9 41.4 36.4 31.3 26.2 21.1 - 67 43.3 2.6 43.3 43.3 39.4 34.5 29.6 24.7 40.2 2.8 40.2 40.2 37.4 32.3 27.2 22.1 62 42.1 2.6 42.1 42.1 40.1 35.2 30.3 25.4 39.3 2.8 39.3 39.3 37.2 32.2 27.1 22.0 57 53.8 2.7 25.9 22.7 17.3 - - - 52.7 3.0 28.7 23.1 17.4 - - - 72 51.7 2.7 37.3 31.9 26.5 21.1 - - 49.3 2.9 37.1 31.5 25.8 20.1 - - 1400 67 49.5 2.7 48.8 41.2 35.8 30.4 24.9 - 45.9 2.9 45.5 39.9 34.2 28.5 22.9 - 62 45.3 2.6 45.3 45.3 43.1 37.7 32.3 26.8 42.0 2.8 42.0 42.0 40.9 35.2 29.5 23.9 57 44.2 2.6 44.2 44.2 43.8 38.4 33.0 27.6 41.1 2.8 41.1 41.1 40.7 35.1 29.4 23.7 72 51.7 2.7 38.5 32.8 27.1 21.4 - - 49.5 3.0 38.7 32.7 26.7 20.6 - - 67 49.5 2.7 49.2 42.3 36.6 30.8 25.1 - 46.1 2.9 45.9 41.4 35.4 29.3 23.3 - 1515 62 45.4 2.6 45.4 45.4 44.2 38.5 32.8 27.0 42.2 2.9 42.2 42.2 41.6 35.6 29.6 23.5 57 44.2 2.6 44.2 44.2 44.0 38.3 32.5 26.8 41.2 2.8 41.2 41.2 41.0 35.0 29.0 23.0 72 51.7 2.7 39.7 33.7 27.7 21.6 - - 49.6 3.0 40.3 33.9 27.5 21.2 - - 1630 67 49.6 2.7 49.6 43.4 37.4 31.3 25.3 - 46.2 2.9 46.2 42.9 36.5 30.1 23.8 - 62 45.4 2.6 45.4 45.4 45.4 39.3 33.3 27.3 42.3 2.9 42.3 42.3 42.3 35.9 29.6 23.2 57 44.2 2.6 44.2 44.2 44.2 38.1 32.1 26.1 41.3 2.8 41.3 41.3 41.3 35.0 28.6 22.2 95°F 105°F 77 45.2 3.2 19.8 16.9 12.9 - - - 42.2 3.5 19.4 15.4 11.9 - - - 875 72 41.1 3.1 26.5 22.5 18.5 14.5 - - 37.7 3.4 25.4 21.3 17.2 13.1 - - 67 37.0 3.1 33.2 28.1 24.1 20.1 16.1 - 33.3 3.3 31.4 27.2 22.5 18.4 14.4 - 62 33.9 3.0 33.9 33.9 28.6 24.6 20.6 16.6 32.4 3.3 32.4 32.4 26.7 22.6 18.5 14.4 57 47.3 3.2 23.7 19.1 14.4 - - - 44.0 3.5 24.2 18.1 13.4 - - - 77 43.1 3.2 30.0 25.3 20.7 16.1 - - 39.4 3.4 28.9 24.1 19.4 14.7 - - 1050 72 38.8 3.1 36.2 31.6 26.9 22.3 17.7 - 34.8 3.3 33.5 30.1 25.4 20.6 15.9 - 67 35.5 3.1 35.5 35.5 32.0 27.3 22.7 18.0 33.9 3.3 33.9 33.9 30.0 25.3 20.6 15.8 62 34.9 3.1 34.9 34.9 31.1 26.5 21.8 17.2 32.2 3.3 32.2 32.2 28.3 23.5 18.8 14.1 57 49.5 3.2 27.7 21.3 16.0 - - - 45.9 3.5 29.1 20.9 14.9 - - - 77 45.0 3.2 33.5 28.2 22.9 17.6 - - 41.1 3.4 32.3 27.0 21.6 16.2 - - 1225 72 40.5 3.1 39.3 35.1 29.8 24.5 19.2 - 36.3 3.4 35.6 33.0 28.2 22.8 17.4 - 67 37.1 3.1 37.1 37.1 35.3 30.0 24.8 19.5 35.3 3.3 35.3 35.3 33.4 28.0 22.6 17.2 62 36.4 3.1 36.4 36.4 34.4 29.1 23.8 18.6 33.6 3.3 33.6 33.6 31.4 26.0 20.6 15.2 57 51.6 3.3 31.6 23.4 17.5 - - - 47.8 3.5 33.9 23.7 16.4 - - - 72 46.9 3.2 36.9 31.0 25.1 19.1 - - 42.8 3.5 35.8 29.8 23.7 17.7 - - 1400 67 42.3 3.1 42.3 38.6 32.6 26.7 20.8 - 37.8 3.4 37.8 35.9 31.0 25.0 18.9 - 62 38.7 3.1 38.7 38.7 38.7 32.8 26.8 20.9 36.8 3.3 36.8 36.8 36.8 30.7 24.7 18.6 57 38.0 3.1 38.0 38.0 37.7 31.8 25.8 19.9 34.9 3.3 34.9 34.9 34.6 28.5 22.5 16.4 - 72 47.3 3.2 38.9 32.5 26.2 19.9 - - 43.1 3.5 37.7 31.3 24.8 18.3 - - 67 42.6 3.2 42.6 40.5 34.1 27.8 21.5 - 38.0 3.4 38.0 37.0 32.4 26.0 19.5 - 1515 62 39.0 3.1 39.0 39.0 39.0 32.7 26.3 20.0 37.0 3.3 37.0 37.0 37.0 30.6 24.1 17.7 57 38.3 3.1 38.3 38.3 38.1 31.8 25.5 19.2 35.2 3.3 35.2 35.2 35.0 28.6 22.1 15.6 72 47.6 3.2 40.8 34.1 27.4 20.7 - - 43.4 3.5 39.6 32.8 25.9 19.0 - - 1630 67 42.9 3.2 42.9 42.4 35.7 29.0 22.3 - 38.3 3.4 38.3 38.1 33.8 27.0 20.1 - 62 39.2 3.1 39.2 39.2 39.2 32.5 25.8 19.1 37.3 3.4 37.3 37.3 37.3 30.4 23.6 16.7 57 38.5 3.1 38.5 38.5 38.5 31.8 25.1 18.4 35.5 3.4 35.5 35.5 35.5 28.6 21.7 14.8 Johnson Controls Unitary Products 21 1. limiloommoinft 718444-YTG-H-0414 DNZ042(3.5 Ton)(Continued) Air on Temperature of Air on Condenser Coil ry Evaporator Coil Net Total Sensible Capacity(MBh) _ Net Total Sensible Capacity(MBh) ry CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) 11 (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 115°F 125°F i1 77 39.1 3.8 18.9 13.9 10.9 - - - 36.1 4.1 20.4 11.9 9.9 72 34.3 3.7 24.2 20.1 15.9 11.8 - - 31.0 3.9 23.1 18.9 14.6 10.4 I' 875 67 29.6 3.6 29.6 26.3 20.9 16.8 12.6 - 25.8 3.8 25.8 25.8 19.3 15.1 10.9 62 31.0 3.5 31.0 31.0 24.8 20.6 16.4 12.3 29.5 3.8 29.5 29.5 22.9 18.6 14.4 10.1 57 40.7 3.8 24.7 17.2 12.4 - - - 37.5 4.1 26.4 16.6 11.4 - - - 1 77 35.8 3.7 27.7 22.9 18.1 13.2 - - 32.1 3.9 26.6 21.7 16.8 11.8 1050 72 30.8 3.6 30.8 28.6 23.8 18.9 14.1 - 26.8 3.8 26.8 26.8 22.2 17.3 12.3 - 67 32.3 3.5 32.3 32.3 28.1 23.3 18.5 13.6 30.7 3.8 30.7 30.7 26.2 21.3 16.4 11.4 62 29.5 3.6 29.5 29.5 25.4 20.6 15.7 10.9 26.9 3.8 26.9 26.9 22.5 17.6 12.7 7.8 57 42.4 3.8 30.5 20.6 13.9 38.8 4.1 32.5 21.3 12.8 - 77 37.2 3.7 31.2 25.7 20.2 14.7 33.3 4.0 30.1 24.5 18.9 13.3 - 1225 72 32.0 3.6 32.0 30.9 26.6 21.1 15.6 - 27.7 3.8 27.7 27.7 25.0 19.4 13.8 - 67 33.6 3.6 33.6 33.6 31.5 26.0 20.5 15.0 31.8 3.8 31.8 31.8 29.6 24.0 18.3 12.7 62 30.7 3.6 30.7 30.7 28.4 22.9 17.4 11.9 27.8 3.8 27.8 27.8 25.4 19.8 14.2 8.6 57 44.0 3.8 36.2 23.9 15.3 - - - 40.2 4.1 38.5 26.0 14.3 - - - 72 38.6 3.7 34.7 28.6 22.4 16.2 - - 34.4 4.0 33.6 27.3 21.1 14.8 - - 1400 67 33.2 3.6 33.2 33.2 29.4 23.3 17.1 - 28.7 3.8 28.7 28.7 27.8 21.6 15.3 - 62 34.8 3.6 34.8 34.8 34.8 28.7 22.5 16.3 32.9 3.8 32.9 32.9 32.9 26.6 20.3 14.1 57 31.9 3.6 31.9 31.9 31.5 25.3 19.1 13.0 28.8 3.8 28.8 28.8 28.3 22.1 15.8 9.5 72 38.9 3.7 36.6 30.0 23.4 16.8 - - 34.7 4.0 34.7 28.7 22.0 15.2 - - 1515 67 33.5 3.6 33.5 33.5 30.7 24.1 17.5 - 29.0 3.9 29.0 29.0 29.0 22.3 15.5 - 62 35.1 3.6 35.1 35.1 35.1 28.5 21.9 15.3 33.2 3.8 33.2 33.2 33.2 26.4 19.7 12.9 57 32.1 3.6 32.1 32.1 31.9 25.3 18.7 12.1 29.1 3.8 29.1 29.1 28.8 22.1 15.3 8.5 72 39.2 3.7 38.5 31.4 24.4 17.3 - - 35.0 4.0 35.0 30.1 22.9 15.6 - - 1630 67 33.8 3.6 33.8 33.8 32.0 25.0 17.9 - 29.2 3.9 29.2 29.2 29.2 23.0 15.8 - 62 35.4 3.6 35.4 35.4 35.4 28.3 21.3 14.2 33.5 3.9 33.5 33.5 33.5 26.2 19.0 11.8 57 32.4 3.6 32.4 32.4 32.4 25.3 18.3 11.2 29.3 3.9 29.3 29.3 29.3 22.1 14.8 7.6 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 22 Johnson Controls Unitary Products 718444-YTG-H-0414 DNZ048(4.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW? 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 53.0 2.7 26.5 21.2 16.8 - - - 52.6 3.1 24.9 20.8 16.3 - - - 1000 72 50.4 2.7 32.3 27.9 23.5 19.1 - - 49.3 3.1 31.8 27.4 22.9 18.4 - - 67 47.8 2.7 38.1 34.6 30.2 25.8 21.4 - 46.0 3.1 38.8 33.9 29.5 25.0 20.5 - 62 43.4 2.7 43.4 40.9 34.6 30.2 25.8 21.4 41.8 3.1 41.8 40.5 33.7 29.3 24.8 20.3 77 55.6 2.7 28.7 23.6 18.6 - - - 54.5 3.2 28.3 23.2 18.0 - - - 72 52.8 2.7 36.2 31.1 26.0 20.9 - - 51.0 3.1 35.6 30.4 25.3 20.1 - - 1200 67 50.1 2.7 43.6 38.5 33.4 28.4 23.3 - 47.6 3.1 42.9 37.7 32.5 27.4 22.2 - 62 45.5 2.7 45.5 43.8 38.3 33.2 28.1 23.0 43.3 3.1 43.3 42.4 37.3 32.1 26.9 21.8 57 44.1 2.7 44.1 44.1 40.0 34.9 29.9 24.8 42.6 3.1 42.6 42.6 38.1 33.0 27.8 22.7 77 58.1 2.8 30.9 26.1 20.3 - - - 56.4 3.2 31.8 25.5 19.7 - - - 72 55.3 2.8 40.0 34.3 28.5 22.7 - - 52.8 3.2 39.3 33.5 27.6 21.8 - - 1400 67 52.4 2.7 49.1 42.4 36.7 30.9 25.1 - 49.3 3.1 46.9 41.4 35.6 29.7 23.9 - 62 47.6 2.8 47.6 46.7 42.0 36.2 30.4 24.7 44.8 3.1 44.8 44.4 40.8 34.9 29.1 23.2 57 46.1 2.7 46.1 46.1 43.9 38.1 32.4 26.6 44.0 3.1 44.0 44.0 41.7 35.9 30.0 24.2 77 60.7 2.8 33.1 28.6 22.1 - - - 58.3 3.2 35.2 27.9 21.4 - - - 72 57.7 2.8 43.9 37.4 31.0 24.6 - - 54.6 3.2 43.1 36.6 30.0 23.5 - - 1600 67 54.7 2.8 54.7 46.3 39.9 33.4 27.0 - 50.9 3.2 50.9 45.2 38.7 32.1 25.6 - 62 49.6 2.8 49.6 49.6 45.7 39.2 32.8 26.3 46.3 3.2 46.3 46.3 44.3 37.8 31.2 24.7 57 48.1 2.7 48.1 48.1 47.7 41.3 34.9 28.4 45.5 3.1 45.5 45.5 45.3 38.8 32.3 25.7 72 56.9 2.8 45.7 38.8 32.0 25.1 - - 54.1 3.2 45.0 38.0 30.9 23.9 - - 1750 67 53.9 2.8 53.9 48.2 41.1 34.2 27.3 - 50.5 3.1 50.5 46.9 39.8 32.8 25.8 - 62 49.0 2.8 49.0 49.0 47.0 40.1 33.2 26.3 45.9 3.2 45.9 45.9 44.9 37.9 30.9 23.9 57 47.5 2.7 47.5 47.5 47.3 40.4 33.5 26.6 45.1 3.1 45.1 45.1 45.1 38.1 31.0 24.0 72 56.1 2.8 47.6 40.2 32.9 25.6 - - 53.7 3.2 46.8 39.3 31.9 24.4 - - 67 53.2 2.7 53.2 50.0 42.3 35.0 27.7 - 50.1 3.1 50.1 48.5 41.0 33.6 26.1 - 1900 62 48.3 2.8 48.3 48.3 48.3 41.0 33.7 26.3 45.5 3.1 45.5 45.5 45.5 38.0 30.6 23.1 57 46.8 2.7 46.8 46.8 46.8 39.5 32.2 24.8 44.8 3.1 44.8 44.8 44.8 37.3 29.8 22.3 95°F 105°F 77 52.1 3.6 23.2 20.4 15.8 - - - 49.1 4.1 21.6 19.7 15.2 - - - 1000 72 48.1 3.5 31.3 26.8 22.3 17.7 - - 45.2 4.1 30.3 25.8 21.4 16.9 - - 67 44.1 3.5 39.5 33.2 28.7 24.2 19.6 - 41.4 4.1 39.0 32.0 27.5 23.1 18.6 - 62 40.1 3.5 40.1 40.1 32.9 28.3 23.8 19.3 38.1 4.1 38.1 38.1 31.2 26.8 22.3 17.8 77 53.4 3.6 27.9 22.7 17.4 - - - 50.1 4.1 27.1 21.9 16.7 - - - 72 49.3 3.5 35.0 29.8 24.5 19.3 - - 46.2 4.1 33.9 28.7 23.5 18.3 - - 1200 67 45.2 3.5 42.1 36.9 31.6 26.4 21.1 - 42.3 4.1 40.7 35.5 30.3 25.1 19.9 - 62 41.0 3.5 41.0 41.0 36.2 31.0 25.8 20.5 38.9 4.1 38.9 38.9 34.3 29.1 23.9 18.7 57 41.1 3.5 41.1 41.1 36.3 31.0 25.8 20.5 39.3 4.1 39.3 39.3 34.5 29.3 24.1 18.9 77 54.6 3.6 32.6 25.0 19.0 - - - 51.1 4.1 32.6 24.1 18.2 - - - 72 50.4 3.6 38.6 32.7 26.8 20.9 - - 47.2 4.1 37.5 31.5 25.6 19.7 - - 1400 67 46.2 3.5 44.7 40.5 34.5 28.6 22.7 - 43.2 4.1 42.4 38.9 33.0 27.1 21.1 - 62 42.0 3.5 42.0 42.0 39.6 33.7 27.7 21.8 39.7 4.1 39.7 39.7 37.4 31.5 25.6 19.6 57 42.0 3.5 42.0 42.0 39.6 33.7 27.7 21.8 40.1 4.1 40.1 40.1 37.6 31.6 25.7 19.8 77 55.8 3.6 37.4 27.3 20.7 - - - 52.2 4.1 38.1 26.4 19.7 - - - 72 51.5 3.6 42.3 35.7 29.1 22.4 - - 48.1 4.1 41.1 34.4 27.7 21.1 - - 1600 67 47.2 3.5 47.2 44.1 37.5 30.8 24.2 - 44.1 4.1 44.1 42.4 35.7 29.1 22.4 - 62 42.9 3.5 42.9 42.9 42.9 36.3 29.7 23.1 40.5 4.1 40.5 40.5 40.5 33.8 27.2 20.5 57 42.9 3.5 42.9 42.9 42.9 36.3 29.7 23.1 40.9 4.1 40.9 40.9 40.7 34.0 27.4 20.7 72 51.4 3.6 44.2 37.1 29.9 22.8 - - 48.0 4.1 43.1 36.0 28.8 21.7 - - 1750 67 47.1 3.5 47.1 45.5 38.6 31.5 24.4 - 43.9 4.1 43.9 43.1 37.2 30.0 22.8 - 62 42.8 3.5 42.8 42.8 42.8 35.7 28.6 21.4 40.4 4.0 40.4 40.4 40.4 33.2 26.0 18.9 57 42.8 3.5 42.8 42.8 42.8 35.7 28.6 21.5 40.8 4.1 40.8 40.8 40.7 33.5 26.3 19.1 72 51.2 3.6 46.1 38.4 30.8 23.2 - - 47.8 4.1 45.2 37.6 30.0 22.3 - - 1900 67 47.0 3.5 47.0 47.0 39.7 32.1 24.5 - 43.8 4.1 43.8 43.8 38.6 30.9 23.3 - 62 42.7 3.5 42.7 42.7 42.7 35.1 27.5 19.8 40.2 4.0 40.2 40.2 40.2 32.6 24.9 17.2 57 42.7 3.5 42.7 42.7 42.7 35.1 27.5 19.9 40.6 4.1 40.6 40.6 40.6 32.9 25.3 17.6 Johnson Controls Unitary Products 23 7.18444-YTG-H-0414 a DNZ048(4.0 Ton)(Continued) r •' Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Capacity(MBh ) Ca y( ) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) j CFM (°F) (MBh) (kW? 90 85 80 I 75 I 70 65 (MBh) (kW)2 90 I 85 I 80 75 I 70 I 65 115°F 125°F 77 46.0 4.7 20.1 19.0 14.6 - - - 42.9 5.3 20.4 17.6 13.9 - - - 1000 72 42.3 4.7 29.2 24.9 20.5 16.1 - - 39.4 5.3 28.2 23.9 19.6 15.3 - - 67 38.7 4.6 38.4 30.8 26.4 22.0 17.6 - 36.0 5.2 36.0 29.5 25.2 20.9 16.6 - 62 36.1 4.6 36.1 36.1 29.6 25.2 20.8 16.4 34.0 5.2 34.0 34.0 27.9 23.6 19.3 15.0 77 46.8 4.7 26.3 21.1 16.0 - - - 43.6 5.3 26.8 20.4 15.2 - - - 72 43.1 4.7 32.8 27.6 22.4 17.3 - - 40.1 5.2 31.7 26.5 21.4 16.3 - - 1200 67 39.4 4.6 39.2 34.1 28.9 23.8 18.6 - 36.5 5.2 36.5 32.7 27.6 22.5 17.3 - 62 36.7 4.6 36.7 36.7 32.4 27.2 22.1 16.9 34.6 5.2 34.6 34.6 30.5 25.4 20.2 15.1 57 37.4 4.6 37.4 37.4 32.7 27.5 22.4 17.2 35.6 5.2 35.6 35.6 30.9 25.8 20.7 15.5 77 47.7 4.7 32.5 23.3 17.4 - - - 44.3 5.3 33.1 23.1 16.5 - - - 72 43.9 4.7 36.3 30.4 24.4 18.5 - - 40.7 5.2 35.1 29.2 23.2 17.3 - 1400 67 40.1 4.6 40.1 37.4 31.5 25.5 19.6 37.1 5.2 37.1 35.9 29.9 24.0 18.1 62 37.4 4.6 37.4 37.4 35.3 29.3 23.4 17.4 35.1 5.1 35.1 35.1 33.1 27.2 21.2 15.3 57 38.1 4.6 38.1 38.1 35.6 29.6 23.7 17.8 36.2 5.1 36.2 36.2 33.5 27.6 21.7 15.7 77 48.6 4.7 38.8 25.5 18.8 - - - 45.0 5.2 39.4 25.9 17.8 - - - 72 44.7 4.7 39.8 33.1 26.4 19.7 - - 41.3 5.2 38.6 31.8 25.1 18.3 - - i 1600 67 40.9 4.6 40.9 40.7 34.0 27.3 20.6 - 37.7 5.1 37.7 37.7 32.3 25.5 18.8 - 62 38.1 4.6 38.1 38.1 38.1 31.4 24.7 18.0 35.7 5.1 35.7 35.7 35.7 28.9 22.2 15.4 57 38.8 4.6 38.8 38.8 38.4 31.7 25.0 18.3 36.8 5.1 36.8 36.8 36.2 29.4 22.7 15.9 72 44.5 4.7 42.1 35.0 27.7 20.5 - - 41.1 5.2 41.0 33.9 26.6 19.4 - - 67 40.7 4.6 40.7 40.6 35.7 28.5 21.3 - 37.5 5.1 37.5 37.5 34.3 27.0 19.8 - 1750 62 38.0 4.6 38.0 38.0 38.0 30.7 23.5 16.3 35.5 5.1 35.5 35.5 35.5 28.3 21.0 13.7 57 38.7 4.6 38.7 38.7 38.5 31.3 24.0 16.8 36.6 5.1 36.6 36.6 36.3 29.0 21.8 14.5 72 44.4 4.6 44.4 36.8 29.1 21.3 - - 40.9 5.2 40.9 36.0 28.2 20.4 - - 1900 67 40.6 4.6 40.6 40.6 37.5 29.7 22.0 - 37.3 5.1 37.3 37.3 36.3 28.6 20.8 - 62 37.8 4.6 37.8 37.8 37.8 30.1 22.3 14.6 35.4 5.1 35.4 35.4 35.4 27.6 19.8 12.0 57 38.5 4.6 38.5 38.5 38.5 30.8 23.1 15.3 36.4 5.1 36.4 36.4 36.4 28.6 20.9 13.1 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 24 Johnson Controls Unitary Products • 718444-YTG-H-0414 DNZ060(5.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 67.6 3.6 34.0 27.8 22.5 - - - 65.0 4.0 32.3 26.7 21.1 - - - 1375 72 62.2 3.5 40.4 35.1 29.8 24.6 - - 60.3 4.0 40.1 34.5 28.9 23.3 - - 67 56.9 3.4 46.7 42.4 37.1 31.8 26.6 - 55.6 3.9 47.9 42.3 36.7 31.1 25.5 - 62 52.9 3.4 52.9 52.9 44.9 39.6 34.4 29.1 51.5 3.9 51.5 51.5 43.9 38.3 32.7 27.1 77 70.0 3.5 36.3 30.4 24.5 - - - 66.5 4.0 34.9 28.8 22.7 - - - 72 64.5 3.5 44.2 38.3 32.4 26.6 - - 61.7 4.0 43.3 37.2 31.2 25.1 - - 1500 67 59.0 3.4 52.2 46.3 40.4 34.5 28.6 - 56.9 3.9 51.7 45.7 39.6 33.5 27.4 - 62 54.8 3.4 54.8 54.8 48.9 43.0 37.1 31.2 52.7 3.9 52.7 52.7 47.3 41.2 35.1 29.1 57 53.6 3.4 53.6 53.6 49.3 43.5 37.6 31.7 52.6 3.9 52.6 52.6 47.5 41.4 35.3 29.2 77 72.5 3.5 38.5 32.9 26.5 - - - 68.0 4.0 37.5 30.9 24.4 - - - 72 66.8 3.5 48.0 41.6 35.1 28.6 - - 63.1 3.9 46.5 40.0 33.4 26.9 - - 1625 67 61.1 3.4 57.6 50.2 43.7 37.2 30.7 - 58.2 3.9 55.6 49.0 42.4 35.9 29.3 - 62 56.8 3.4 56.8 56.8 52.8 46.3 39.8 33.3 53.9 3.9 53.9 53.9 50.7 44.1 37.6 31.0 57 55.5 3.4 55.5 55.5 53.3 46.8 40.4 33.9 53.8 3.9 53.8 53.8 50.9 44.3 37.8 31.2 77 75.0 3.5 40.7 35.5 28.4 - - - 69.5 4.0 40.1 33.1 26.0 - - - 72 69.1 3.5 51.9 44.8 37.7 30.6 - - 64.5 3.9 49.7 42.7 35.7 28.6 - - 1750 67 63.2 3.4 63.1 54.1 47.0 39.9 32.8 - 59.4 3.9 59.4 52.3 45.3 38.3 31.2 - 62 58.8 3.4 58.8 58.8 56.8 49.7 42.6 35.5 55.1 3.9 55.1 55.1 54.1 47.1 40.0 33.0 57 57.5 3.4 57.5 57.5 57.3 50.2 43.1 36.0 55.0 3.9 55.0 55.0 54.3 47.3 40.2 33.2 72 68.5 3.5 52.6 45.0 37.3 29.7 - - 64.5 3.9 50.7 43.2 35.7 28.1 - - 1875 67 62.7 3.4 62.6 54.1 46.5 38.9 31.3 - 59.4 3.9 59.4 52.8 45.3 37.8 30.2 - 62 58.2 3.4 58.2 58.2 56.2 48.6 41.0 33.4 55.1 3.9 55.1 55.1 54.1 46.6 39.0 31.5 57 57.0 3.4 57.0 57.0 56.8 49.2 41.6 34.0 55.0 3.9 55.0 55.0 54.3 46.8 39.2 31.7 72 67.9 3.5 53.2 45.1 37.0 28.9 - - 64.5 3.9 51.7 43.7 35.7 27.6 - - 2000 67 62.1 3.4 62.1 54.2 46.1 38.0 29.8 - 59.4 3.9 59.4 53.3 45.3 37.3 29.2 - 62 57.7 3.4 57.7 57.7 55.7 47.6 39.5 31.4 55.1 3.9 55.1 55.1 54.1 46.1 38.0 30.0 57 56.4 3.4 56.4 56.4 56.3 48.2 40.0 31.9 55.0 3.9 55.0 55.0 54.3 46.3 38.2 30.2 95°F 105°F 77 62.5 4.4 30.6 25.6 19.7 - - - 59.6 5.2 29.3 24.8 18.8 - - - 1375 72 58.4 4.4 39.8 33.9 28.0 22.1 - - 55.2 5.1 38.7 32.8 26.8 20.8 - - 67 54.3 4.4 49.1 42.3 36.3 30.4 24.5 - 50.8 5.1 48.2 40.8 34.8 28.8 22.9 - 62 50.2 4.4 50.2 50.2 42.8 36.9 31.0 25.1 47.8 5.1 47.8 47.8 40.5 34.5 28.5 22.5 77 63.0 4.4 33.5 27.3 21.0 - - - 60.1 5.1 33.4 26.5 20.1 - - - 72 58.9 4.4 42.4 36.2 29.9 23.6 - - 55.7 5.1 41.5 35.1 28.7 22.3 - - 1500 67 54.8 4.4 51.3 45.0 38.8 32.5 26.2 - 51.2 5.1 49.5 43.7 37.3 30.9 24.5 - 62 50.6 4.4 50.6 50.6 45.7 39.4 33.2 26.9 48.2 5.1 48.2 48.2 43.3 37.0 30.6 24.2 57 51.6 4.3 51.6 51.6 45.6 39.3 33.0 26.8 48.9 5.0 48.9 48.9 43.1 36.7 30.3 24.0 77 63.5 4.4 36.5 28.9 22.3 - - - 60.7 5.1 37.5 28.3 21.5 - - - 72 59.4 4.4 45.0 38.4 31.8 25.1 - - 56.2 5.1 44.2 37.4 30.6 23.8 - - 1625 67 55.2 4.4 53.5 47.8 41.2 34.6 28.0 - 51.7 5.1 50.8 46.5 39.8 33.0 26.2 - 62 51.0 4.4 51.0 51.0 48.6 41.9 35.3 28.7 48.6 5.1 48.6 48.6 46.2 39.4 32.6 25.9 57 52.0 4.4 52.0 52.0 48.4 41.8 35.2 28.6 49.4 5.0 49.4 49.4 45.9 39.2 32.4 25.6 77 64.0 4.4 39.5 30.6 23.6 - - - 61.2 5.1 41.6 30.0 22.8 - - - 72 59.8 4.4 47.6 40.6 33.6 26.7 - - 56.6 5.1 46.9 39.7 32.5 25.4 - - 1750 67 55.7 4.4 55.7 50.6 43.6 36.7 29.7 - 52.1 5.0 52.1 49.4 42.2 35.1 27.9 - 62 51.4 4.4 51.4 51.4 51.4 44.4 37.5 30.5 49.1 5.0 49.1 49.1 49.1 41.9 34.7 27.5 57 52.5 4.4 52.5 52.5 51.3 44.3 37.4 30.4 49.8 5.0 49.8 49.8 48.8 41.6 34.4 27.3 72 60.4 4.4 48.9 41.4 34.0 26.5 - - 56.9 5.1 48.1 40.4 32.7 25.0 - - 1875 67 56.2 4.4 56.2 51.6 44.1 36.6 29.1 - 52.4 5.0 52.4 50.0 42.5 34.8 27.1 - 62 51.9 4.4 51.9 51.9 51.9 44.5 37.0 29.5 49.3 5.0 49.3 49.3 49.3 41.6 34.0 26.3 57 53.0 4.4 53.0 53.0 51.8 44.4 36.9 29.4 50.1 5.0 50.1 50.1 49.1 41.4 33.7 26.0 72 61.1 4.4 50.3 42.3 34.3 26.3 - - 57.3 5.1 49.3 41.1 32.9 24.7 - - 2000 67 56.8 4.4 56.8 52.5 44.5 36.6 28.6 - 52.7 5.0 52.7 50.5 42.7 34.5 26.3 - 62 52.5 4.4 52.5 52.5 52.5 44.5 36.5 28.6 49.6 5.0 49.6 49.6 49.6 41.4 33.2 25.0 57 53.5 4.4 53.5 53.5 52.3 44.4 36.4 28.4 50.3 5.0 50.3 50.3 49.3 41.1 32.9 24.7 Johnson Controls Unitary Products 25 vrimilemirwm+ 718444-YTG-H-0414 . DNZ060(5.0 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total_ Capacity(MBh)Sensible CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I B0 I 75 I 70 I 65 115°F 125°F 77 56.7 5.9 28.1 24.0 17.9 - - - 53.9 6.6 29.4 22.1 17.1 - - - 1375 72 52.0 5.8 37.6 31.6 25.6 19.6 - - 48.8 6.5 36.5 30.5 24.4 18.3 - - 67 47.2 5.7 47.2 39.3 33.3 27.3 21.2 - 43.7 6.4 43.7 37.8 31.7 25.7 19.6 - 62 45.4 5.8 45.4 45.4 38.1 32.1 26.0 20.0 43.1 6.5 43.1 43.1 35.7 29.6 23.6 17.5 77 57.3 5.9 33.3 25.8 19.3 - - - 54.4 6.6 34.9 25.0 18.5 - - - 72 52.5 5.8 40.5 34.0 27.5 21.1 - - 49.3 6.5 39.5 33.0 26.4 19.8 - - 1500 67 47.7 5.7 47.7 42.3 35.8 29.3 22.9 - 44.1 6.4 44.1 40.9 34.3 27.7 21.2 - 62 45.9 5.8 45.9 45.9 41.0 34.5 28.0 21.5 43.5 6.5 43.5 43.5 38.6 32.0 25.4 18.9 57 46.3 5.7 46.3 46.3 40.6 34.1 27.6 21.2 43.6 6.4 43.6 43.6 38.1 31.5 24.9 18.4 77 57.8 5.8 38.6 27.6 20.7 - - - 55.0 6.5 40.4 27.9 19.8 - - - 72 53.0 5.8 43.3 36.4 29.5 22.6 - - 49.8 6.4 42.5 35.4 28.4 21.3 - - 1625 67 48.1 5.7 48.1 45.2 38.3 31.4 24.5 - 44.6 6.3 44.6 43.9 36.9 29.8 22.7 - 62 46.3 5.7 46.3 46.3 43.8 36.9 30.0 23.1 43.9 6.4 43.9 43.9 41.5 34.4 27.3 20.2 57 46.7 5.7 46.7 46.7 43.4 36.5 29.6 22.7 44.0 6.4 44.0 44.0 40.9 33.9 26.8 19.7 77 58.3 5.8 43.8 29.4 22.0 - - - 55.5 6.5 46.0 30.8 21.2 - - - 72 53.4 5.7 46.2 38.8 31.4 24.0 - - 50.2 6.4 45.5 37.9 30.3 22.7 - 1750 67 48.6 5.7 48.6 48.2 40.8 33.5 26.1 - 45.0 6.3 45.0 45.0 39.4 31.9 24.3 - 62 46.7 5.7 46.7 46.7 46.7 39.3 32.0 24.6 44.4 6.4 44.4 44.4 44.4 36.8 29.2 21.6 57 47.1 5.7 47.1 47.1 46.3 38.9 31.5 24.2 44.5 6.3 44.5 44.5 43.8 36.2 28.6 21.0 72 53.4 5.7 47.2 39.3 31.4 23.5 - - 49.9 6.4 46.4 38.3 30.2 22.0 - - 1875 67 48.6 5.7 48.6 48.4 40.8 32.9 25.0 - 44.7 6.3 44.7 44.7 39.2 31.1 23.0 - 62 46.7 5.7 46.7 46.7 46.7 38.8 30.9 23.0 44.1 6.4 44.1 44.1 44.1 36.0 27.9 19.7 57 47.1 5.7 47.1 47.1 46.3 38.4 30.5 22.6 44.2 6.3 44.2 44.2 43.5 35.4 27.3 19.2 72 53.4 5.7 48.3 39.9 31.4 23.0 - - 49.6 6.4 47.3 38.6 30.0 21.3 - - 67 48.6 5.7 48.6 48.6 40.8 32.4 24.0 - 44.4 6.3 44.4 44.4 39.0 30.3 21.7 - 2000 62 46.7 5.7 46.7 46.7 46.7 38.3 29.9 21.4 43.8 6.4 43.8 43.8 43.8 35.2 26.5 17.9 57 47.1 5.7 47.1 47.1 46.3 37.9 29.4 21.0 43.9 6.3 43.9 43.9 43.3 34.6 25.9 17.3 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 26 Johnson Controls Unitary Products f 718444-YTG-H-0414 DNQ024-060 Cooling Capacities DNQ024(2.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil p Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 75 I 70 65 (MBh) (kW)2 90 I 85 80 I 75 I 70 1 65 75°F 85°F 77 34.0 1.5 10.5 8.0 5.6 - - - 30.5 1.7 11.9 9.4 6.9 - - - 72 30.5 1.5 16.4 14.0 11.5 9.1 - - 27.7 1.7 16.7 14.2 11.7 9.3 - - 600 67 27.0 1.6 22.3 19.9 17.5 15.0 12.6 - 25.0 1.7 21.5 19.0 16.5 14.1 11.6 - 62 24.4 1.6 24.4 19.7 17.0 14.5 12.1 9.7 22.6 1.7 22.6 20.3 17.8 15.3 12.8 10.4 57 25.1 1.6 25.1 21.5 18.8 16.4 13.9 11.5 22.9 1.7 22.9 21.2 18.7 16.2 13.7 11.3 77 35.0 1.5 12.7 9.5 6.8 - - - 31.5 1.7 13.8 10.7 7.9 - - - 72 31.4 1.5 19.1 16.4 13.8 11.1 - - 28.6 1.7 18.9 16.2 13.4 10.7 - - 700 67 27.8 1.6 25.4 23.4 20.8 18.1 15.5 - 25.7 1.7 24.0 21.7 18.9 16.2 13.4 - 62 25.0 1.6 25.0 22.7 20.3 17.7 15.1 12.4 23.3 1.7 23.3 22.1 20.3 17.6 14.8 12.1 57 25.8 1.6 25.8 24.0 22.4 19.8 17.1 14.5 23.7 1.7 23.7 22.8 21.4 18.6 15.9 13.1 77 35.9 1.5 15.0 10.9 8.0 - - - 32.4 1.7 15.8 11.9 8.9 - - - 72 32.2 1.6 21.8 18.9 16.0 13.2 - - 29.5 1.7 21.1 18.1 15.1 12.1 - - 800 67 28.5 1.6 28.5 26.9 24.1 21.2 18.3 - 26.5 1.7 26.5 24.3 21.3 18.3 15.3 - 62 25.7 1.6 25.7 25.7 23.7 20.9 18.0 15.2 24.0 1.7 24.0 24.0 22.9 19.9 16.9 13.8 57 26.4 1.6 26.4 26.4 26.1 23.2 20.4 17.5 24.4 1.7 24.4 24.4 24.1 21.1 18.0 15.0 72 33.0 1.5 22.3 18.9 15.5 12.1 - - 29.8 1.7 21.9 18.5 15.1 11.7 - - 900 67 29.2 1.6 29.2 26.7 23.4 20.0 16.6 - 26.8 1.7 26.8 24.7 21.3 17.9 14.5 - 62 26.3 1.6 26.3 26.3 23.7 20.3 16.9 13.6 24.3 1.7 24.3 24.3 22.9 19.5 16.1 12.7 57 27.1 1.6 27.1 27.1 26.1 22.7 19.3 15.9 24.6 1.7 24.6 24.6 24.1 20.7 17.3 13.9 95°F 105°F 77 27.0 1.9 13.3 10.8 8.3 - - - 25.1 2.0 13.3 10.4 7.9 - - - 72 25.0 1.9 17.0 14.5 12.0 9.4 - - 22.7 2.0 16.3 13.7 11.2 8.7 - - 600 67 22.9 1.9 20.7 18.2 15.6 13.1 10.6 - 20.4 2.0 19.2 17.1 14.6 12.1 9.6 - 62 20.8 1.8 20.8 20.8 18.6 16.1 13.6 11.0 19.0 2.0 19.0 19.0 16.9 14.4 11.9 9.4 57 20.8 1.8 20.8 20.8 18.6 16.1 13.6 11.1 19.1 2.0 19.1 19.1 17.0 14.5 12.0 9.4 77 27.9 1.9 14.9 11.9 9.0 - - - 25.8 2.0 15.4 11.5 8.6 - - - 72 25.8 1.9 18.8 15.9 13.1 10.2 - - 23.3 2.0 17.9 15.0 12.2 9.4 - - 800 67 23.7 1.9 22.6 19.9 17.1 14.3 11.4 - 20.9 2.0 20.3 18.6 15.9 13.1 10.3 - 62 21.6 1.8 21.6 21.6 20.3 17.5 14.6 11.8 19.6 2.0 19.6 19.6 18.4 15.6 12.8 10.0 57 21.6 1.8 21.6 21.6 20.3 17.5 14.6 11.8 19.6 2.0 19.6 19.6 18.5 15.7 12.9 10.0 77 28.9 1.9 16.5 13.0 9.8 - - - 26.4 2.1 17.4 12.6 9.2 - - - 72 26.7 1.9 20.5 17.3 14.2 11.0 - - 23.9 2.0 19.4 16.3 13.2 10.1 - - 800 67 24.5 1.9 24.5 21.7 18.6 15.4 12.2 - 21.4 2.0 21.4 20.1 17.2 14.1 11.0 - 62 22.3 1.8 22.3 22.3 22.0 18.9 15.7 12.5 20.1 2.0 20.1 20.1 19.9 16.8 13.7 10.6 57 22.3 1.8 22.3 22.3 22.1 18.9 15.7 12.5 20.1 2.0 20.1 20.1 20.0 16.9 13.8 10.6 72 26.6 1.9 21.5 18.1 14.7 11.3 - - 24.0 2.0 20.4 17.0 13.7 10.4 - - 900 67 24.4 1.9 24.4 22.7 19.3 15.8 12.4 - 21.5 2.0 21.5 20.6 17.8 14.5 11.2 - 62 22.2 1.8 22.2 22.2 22.1 18.7 15.3 11.9 20.1 2.0 20.1 20.1 20.0 16.7 13.3 10.0 57 22.2 1.8 22.2 22.2 22.1 18.7 15.3 11.9 20.2 2.0 20.2 20.2 20.1 16.7 13.4 10.1 Johnson Controls Unitary Products 27 7 718444-YTG-H-0414 r . DNQ024(2.0 Ton)(Continued) 1 Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) 1 CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 I 75 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 70 I 65 115°F 125°F 77 23.2 2.2 13.2 10.0 7.5 21.3 2.4 14.3 9.5 7.0 - - - 72 20.5 2.2 15.5 13.0 10.5 8.0 - - 18.3 2.3 14.8 12.3 9.8 7.3 - - 600 67 17.8 2.1 17.8 16.1 13.6 11.1 8.6 - 15.3 2.3 15.3 15.0 12.5 10.1 7.6 - 62 17.3 2.1 17.3 17.3 15.3 12.8 10.3 7.8 15.5 2.2 15.5 15.5 13.6 11.1 8.6 6.1 57 17.4 2.1 17.4 17.4 15.3 12.8 10.3 7.8 15.7 2.2 15.7 15.7 13.7 11.2 8.7 6.2 77 23.6 2.2 15.8 11.1 8.1 - - - 21.4 2.4 16.8 11.4 7.6 - - - 72 20.9 2.2 16.9 14.2 11.4 8.6 - - 18.4 2.3 16.0 13.3 10.6 7.8 - - 700 67 18.1 2.1 18.1 17.2 14.7 11.9 9.1 - 15.3 2.3 15.3 15.3 13.5 10.8 8.0 - 62 17.5 2.1 17.5 17.5 16.5 13.8 11.0 8.2 15.5 2.3 15.5 15.5 14.7 11.9 9.2 6.4 57 17.7 2.1 17.7 17.7 16.6 13.8 11.1 8.3 15.7 2.2 15.7 15.7 14.8 12.0 9.3 6.5 77 24.0 2.2 18.4 12.2 8.7 - - - 21.5 2.4 19.3 13.3 8.1 - - - 72 21.2 2.2 18.4 15.3 12.3 9.2 - - 18.4 2.3 17.3 14.3 11.3 8.3 - - 800 67 18.4 2.1 18.4 18.4 15.8 12.8 9.7 - 15.3 2.3 15.3 15.3 14.5 11.5 8.5 - 62 17.8 2.1 17.8 17.8 17.8 14.8 11.7 8.6 15.6 2.3 15.6 15.6 15.6 12.7 9.7 6.7 57 18.0 2.1 18.0 18.0 17.9 14.8 11.8 8.7 15.8 2.3 15.8 15.8 15.8 12.8 9.8 6.8 72 21.3 2.2 19.2 16.0 12.7 9.4 - - 18.7 2.3 18.1 14.9 11.7 8.5 - - 900 67 18.5 2.2 18.5 18.5 16.4 13.1 9.9 - 15.6 2.3 15.6 15.6 15.0 11.8 8.6 - 62 17.9 2.1 17.9 17.9 17.9 14.7 11.4 8.2 15.8 2.3 15.8 15.8 15.8 12.7 9.5 6.3 57 18.1 2.1 18.1 18.1 18.1 14.8 11.5 8.3 16.1 2.3 16.1 16.1 16.1 12.9 9.7 6.5 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 28 Johnson Controls Unitary Products r 718444-YTG-H-0414 • DNQ030(2.5 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) _ Net Total Sensible Capacity(MBh) CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 37.7 1.7 19.0 15.4 11.9 - - - 36.6 1.9 18.7 15.1 11.5 - - - r 72 35.1 1.7 24.4 20.9 17.3 13.8 - - 33.7 1.9 24.0 20.4 16.8 13.2 - - 900 67 32.5 1.7 29.9 26.3 22.8 19.2 15.7 - 30.9 1.9 29.3 25.7 22.1 18.5 14.9 - 62 30.4 1.7 30.4 30.4 27.9 24.3 20.8 17.2 29.1 1.9 29.1 29.1 26.8 23.2 19.6 16.0 57 30.0 1.7 30.0 30.0 27.7 24.2 20.6 17.1 29.1 1.9 29.1 29.1 27.0 23.4 19.8 16.2 77 39.8 1.7 19.6 17.1 13.3 - - - 38.1 1.9 20.5 16.6 12.8 - - - 72 37.0 1.7 26.9 23.2 19.4 15.6 - - 35.2 1.9 26.4 22.5 18.7 14.8 - - 1000 67 34.3 1.7 34.3 29.3 25.5 21.7 17.9 - 32.3 1.9 32.3 28.4 24.6 20.7 16.9 - 62 32.0 1.7 32.0 32.0 31.2 27.4 23.7 19.9 30.3 1.9 30.3 30.3 29.8 26.0 22.2 18.3 57 31.6 1.7 31.6 31.6 31.0 27.2 23.5 19.7 30.3 1.9 30.3 30.3 30.0 26.2 22.4 18.5 72 37.3 1.7 28.7 24.5 20.3 16.1 - - 35.5 1.9 28.1 23.9 19.6 15.3 - - I, 1125 67 34.6 1.7 34.6 30.9 26.7 22.5 18.2 - 32.6 1.9 32.6 30.1 25.8 21.5 17.2 - 62 32.2 1.7 32.2 32.2 31.9 27.6 23.4 19.2 30.6 1.9 30.6 30.6 30.4 26.1 21.8 17.6 57 31.9 1.7 31.9 31.9 31.6 27.3 23.1 18.9 30.6 1.9 30.6 30.6 30.5 26.2 21.9 17.7 72 37.6 1.7 30.5 25.8 21.2 16.5 - - 35.9 1.9 29.9 25.2 20.5 15.8 1250 67 34.8 1.7 34.8 32.5 27.8 23.2 18.5 - 32.9 1.9 32.9 31.7 27.0 22.3 17.5 - 62 32.5 1.7 32.5 32.5 32.5 27.8 23.2 18.5 30.9 1.9 30.9 30.9 30.9 26.2 21.5 16.8 57 32.1 1.7 32.1 32.1 32.1 27.5 22.8 18.1 30.9 1.9 30.9 30.9 30.9 26.2 21.5 16.8 95°F 105°F 77 35.4 2.1 18.4 14.8 11.1 - - - 33.0 2.4 18.5 14.0 10.3 - - - 72 32.3 2.1 23.6 19.9 16.3 12.7 - - 30.2 2.4 22.8 19.1 15.5 11.9 - - 900 67 29.3 2.1 28.8 25.1 21.5 17.8 14.2 - 27.3 2.4 27.0 24.3 20.7 17.0 13.4 - 62 27.8 2.1 27.8 27.8 25.8 22.1 18.5 14.9 26.1 2.4 26.1 26.1 24.1 20.4 16.8 13.2 57 28.2 2.1 28.2 28.2 26.4 22.7 19.1 15.4 26.7 2.4 26.7 26.7 24.8 21.2 17.6 13.9 77 36.4 2.1 21.3 16.2 12.3 - - - 34.0 2.4 21.9 15.4 11.4 - - - 72 33.3 2.1 25.8 21.9 18.0 14.1 - - 31.0 2.4 25.0 21.1 17.1 13.2 - - 1000 67 30.2 2.1 30.2 27.6 23.7 19.8 15.9 - 28.1 2.4 28.1 26.7 22.9 18.9 15.0 - 62 28.7 2.1 28.7 28.7 28.4 24.5 20.6 16.7 26.8 2.4 26.8 26.8 26.6 22.7 18.8 14.9 57 29.1 2.1 29.1 29.1 29.1 25.2 21.3 17.4 27.5 2.4 27.5 27.5 27.5 23.5 19.6 15.7 72 33.7 2.1 27.6 23.2 18.9 14.6 - - 31.3 2.4 26.8 22.4 18.0 13.7 - - 1125 67 30.6 2.1 30.6 29.2 24.9 20.6 16.2 - 28.4 2.4 28.4 27.7 24.1 19.7 15.3 - 62 29.0 2.1 29.0 29.0 28.9 24.6 20.2 15.9 27.1 2.4 27.1 27.1 27.0 22.6 18.2 13.9 57 29.4 2.1 29.4 29.4 29.4 25.1 20.7 16.4 27.7 2.4 27.7 27.7 27.7 23.4 19.0 14.6 72 34.1 2.1 29.4 24.6 19.8 15.0 - - 31.7 2.4 28.7 23.8 19.0 14.1 - - 1250 67 31.0 2.1 31.0 30.9 26.1 21.3 16.6 - 28.7 2.4 28.7 28.6 25.3 20.4 15.6 - 62 29.4 2.1 29.4 29.4 29.4 24.6 19.8 15.1 27.4 2.4 27.4 27.4 27.4 22.5 17.7 12.8 57 29.8 2.1 29.8 29.8 29.8 25.0 20.2 15.4 28.0 2.4 28.0 28.0 28.0 23.2 18.3 13.5 Johnson Controls Unitary Products 29 Numith ,718444-YTG-H-0414 DNQ030(2.5 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 115°F 125°F 77 30.7 2.7 18.6 13.1 9.5 - - - 28.4 3.0 19.0 12.3 8.7 - - - 72 28.0 2.7 21.9 18.3 14.7 11.1 - - 25.8 3.0 21.1 17.5 13.9 10.3 - - 900 67 25.2 2.7 25.2 23.5 19.8 16.2 12.6 - 23.1 3.0 23.1 22.6 19.0 15.4 11.8 - 62 24.3 2.7 24.3 24.3 22.4 18.7 15.1 11.5 22.5 3.0 22.5 22.5 20.6 17.0 13.4 9.8 57 25.2 2.7 25.2 25.2 23.3 19.7 16.1 12.4 23.7 3.0 23.7 23.7 21.7 18.1 14.5 10.9 77 31.5 2.7 22.5 14.6 10.6 - - - 29.1 3.0 23.0 15.1 9.7 - - - 72 28.7 2.7 24.2 20.2 16.3 12.4 - - 26.4 3.0 23.4 19.4 15.5 11.5 - - 1000 67 25.9 2.7 25.9 25.9 22.0 18.1 14.2 - 23.7 3.0 23.7 23.7 21.2 17.3 13.3 - 62 25.0 2.7 25.0 25.0 24.8 20.9 17.0 13.0 23.1 3.0 23.1 23.1 23.0 19.1 15.1 11.2 57 25.9 2.7 25.9 25.9 25.9 21.9 18.0 14.1 24.3 3.0 24.3 24.3 24.3 20.3 16.3 12.4 72 29.0 2.7 26.1 21.6 17.2 12.8 - - 26.6 3.0 25.3 20.8 16.4 11.9 - - 67 26.1 2.7 26.1 26.1 23.3 18.8 14.4 - 23.9 3.0 23.9 23.9 22.4 18.0 13.5 - 1125 62 25.2 2.7 25.2 25.2 25.1 20.7 16.2 11.8 23.2 3.0 23.2 23.2 23.2 18.7 14.2 9.8 57 26.1 2.7 26.1 26.1 26.1 21.7 17.2 12.8 24.4 3.0 24.4 24.4 24.4 19.9 15.5 11.0 72 29.2 2.7 28.0 23.0 18.1 13.2 - - 26.7 3.0 26.7 22.3 17.3 12.3 - - 1250 67 26.3 2.7 26.3 26.3 24.5 19.5 14.6 - 24.0 3.0 24.0 24.0 23.7 18.7 13.6 - 62 25.4 2.7 25.4 25.4 25.4 20.5 15.5 10.6 23.4 3.0 23.4 23.4 23.4 18.4 13.4 8.4 57 26.3 2.7 26.3 26.3 26.3 21.4 16.5 11.5 24.6 3.0 24.6 24.6 24.6 19.6 14.6 9.6 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 30 Johnson Controls Unitary Products i 718444-YTG-H-0414 DNQ036(3.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) CFM WB Capacity Inputt Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 47.5 1.5 23.1 18.9 14.7 - - - 44.6 2.4 23.4 19.0 14.7 - - - 72 43.7 1.9 29.7 25.5 21.3 17.1 - - 41.0 2.5 29.0 24.8 20.6 16.3 - - 1050 67 39.9 2.3 36.3 32.1 27.9 23.6 19.4 - 37.5 2.5 34.7 30.6 26.4 22.1 17.9 - 62 37.1 1.9 37.1 35.4 32.8 28.6 24.4 20.2 34.6 2.5 34.6 33.8 31.4 27.1 22.9 18.7 57 37.4 2.0 37.4 36.6 34.4 30.2 26.0 21.8 35.2 2.5 35.2 34.8 32.9 28.7 24.4 20.2 r 77 47.0 1.6 23.6 19.3 15.0 - - - 44.2 2.4 23.9 19.3 15.0 - - - 72 43.2 2.0 30.4 26.0 21.7 17.3 - - 40.7 2.5 29.6 25.2 20.9 16.5 - - 1100 67 39.5 2.3 37.1 32.7 28.4 24.0 19.7 - 37.2 2.5 35.3 31.1 26.8 22.4 18.0 - 62 36.7 2.0 36.7 35.6 33.4 29.1 24.7 20.4 34.3 2.5 34.3 33.8 31.8 27.4 23.1 18.7 57 37.0 2.0 37.0 36.5 35.0 30.7 26.3 22.0 34.9 2.5 34.9 34.6 33.4 29.0 24.6 20.2 77 46.1 1.7 24.7 20.2 15.5 - - - 43.5 2.4 25.1 20.1 15.4 - - - I 72 42.4 2.1 31.7 27.1 22.5 17.8 - - 40.0 2.5 30.8 26.1 21.5 16.8 - - 1200 67 38.7 2.4 38.7 34.0 29.4 24.7 20.1 - 36.6 2.5 36.6 32.2 27.5 22.9 18.2 - 62 36.0 2.1 36.0 36.0 34.6 30.0 25.4 20.8 33.8 2.5 33.8 33.8 32.7 28.1 23.4 18.7 57 36.3 2.1 36.3 36.3 36.3 31.6 27.0 22.4 34.3 2.5 34.3 34.3 34.3 29.7 25.0 20.3 j 72 43.4 1.7 33.7 28.4 23.1 17.8 - - 40.5 2.5 33.0 27.7 22.5 17.3 - - 1350 67 39.6 2.1 39.6 35.5 30.2 25.0 19.7 - 37.0 2.5 37.0 34.1 28.9 23.6 18.4 - 62 36.8 1.7 36.8 36.8 36.8 31.5 26.3 21.0 34.1 2.5 34.1 34.1 34.1 28.9 23.6 18.4 57 37.1 1.8 37.1 37.1 37.1 31.9 26.6 21.3 34.7 2.5 34.7 34.7 34.7 29.5 24.2 19.0 95°F 105°F 77 41.7 3.3 23.6 19.0 14.8 - - - 38.7 3.5 23.2 17.7 13.4 - - - 72 38.4 3.0 28.3 24.1 19.8 15.6 - - 35.5 3.4 27.1 22.9 18.7 14.4 - - 1050 67 35.1 2.7 33.0 29.1 24.9 20.6 16.4 - 32.2 3.3 31.0 28.1 23.9 19.7 15.5 - 62 32.1 3.1 32.1 32.1 29.9 25.6 21.4 17.1 29.9 3.5 29.9 29.7 27.6 23.4 19.1 14.9 57 33.0 3.0 33.0 33.0 31.4 27.1 22.9 18.7 30.8 3.4 30.8 30.6 28.9 24.6 20.4 16.2 77 41.4 3.3 24.2 19.3 14.9 - - - 38.5 3.5 24.2 18.0 13.6 - - - 72 38.1 2.9 28.9 24.4 20.0 15.6 - - 35.2 3.4 27.7 23.3 18.9 14.6 - - 1100 67 34.9 2.6 33.5 29.6 25.2 20.8 16.3 - 32.0 3.2 31.2 28.6 24.3 19.9 15.5 - 62 31.9 3.0 31.9 31.9 30.2 25.8 21.4 17.0 29.7 3.5 29.7 29.6 28.0 23.6 19.2 14.8 57 32.8 3.0 32.8 32.8 31.7 27.3 22.9 18.5 30.5 3.4 30.5 30.4 29.3 24.9 20.5 16.2 77 40.9 3.1 25.4 20.0 15.2 - - - 37.9 3.4 26.1 18.8 14.0 - - - 72 37.7 2.8 29.9 25.2 20.5 15.7 - - 34.8 3.3 28.9 24.2 19.5 14.8 - - 1200 67 34.5 2.5 34.5 30.4 25.7 21.0 16.2 - 31.6 3.2 31.6 29.6 25.0 20.3 15.6 - 62 31.5 2.9 31.5 31.5 30.8 26.1 21.4 16.7 29.3 3.4 29.3 29.3 28.8 24.1 19.4 14.7 57 32.4 2.9 32.4 32.4 32.4 27.7 23.0 18.2 30.1 3.4 30.1 30.1 30.1 25.4 20.8 16.1 72 37.5 3.2 32.3 27.1 21.9 16.7 - - 34.7 3.5 31.0 25.8 20.6 15.4 - - 67 34.3 2.9 34.3 32.7 27.5 22.3 17.1 - 31.5 3.3 31.5 30.7 26.5 21.3 16.1 - 1350 62 31.4 3.3 31.4 31.4 31.4 26.2 21.0 15.8 29.3 3.6 29.3 29.3 29.3 24.1 18.9 13.7 57 32.3 3.2 32.3 32.3 32.3 27.1 21.9 16.7 30.1 3.5 30.1 30.1 30.1 24.9 19.7 14.5 Johnson Controls Unitary Products 31 i 7.18444-YTG-H-0414 r a DNQ036(3.0 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) _ Net Total Sensible Capacity(MBh) CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW) 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 115°F 125°F 77 35.8 3.7 22.8 16.3 12.0 - - - 32.8 3.8 22.7 15.9 10.6 - - - 72 32.6 3.8 25.9 21.7 17.5 13.3 - - 29.7 4.1 24.6 20.5 16.3 12.1 - - 1050 67 29.4 3.8 28.9 27.1 23.0 18.8 14.6 - 26.6 4.4 26.6 26.0 22.0 17.8 13.7 - 62 27.8 3.9 27.8 27.3 25.3 21.1 16.9 12.7 25.6 4.3 25.6 24.9 23.0 18.8 14.6 10.4 57 28.5 3.8 28.5 28.2 26.3 22.1 17.9 13.7 26.3 4.2 26.3 25.8 23.8 19.6 15.4 11.3 77 35.5 3.7 24.2 16.7 12.2 - - - 32.5 3.9 24.3 16.8 10.9 - - - 72 32.3 3.8 26.5 22.2 17.8 13.5 - - 29.4 4.2 25.3 21.0 16.7 12.4 - - 1100 67 29.2 3.9 28.9 27.6 23.4 19.1 14.7 - 26.4 4.5 26.4 26.0 22.5 18.2 13.9 - 62 27.5 3.9 27.5 27.3 25.8 21.4 17.1 12.7 25.3 4.4 25.3 24.9 23.5 19.2 14.9 10.6 57 28.3 3.8 28.3 28.1 26.8 22.5 18.1 13.8 26.0 4.3 26.0 25.7 24.4 20.1 15.7 11.4. 77 34.9 3.7 26.9 17.6 12.7 - - - 31.9 4.0 27.6 18.4 11.4 - - - 72 31.8 3.8 27.8 23.1 18.5 13.8 - - 28.9 4.3 26.7 22.1 17.5 12.9 - - 1200 67 28.7 3.9 28.7 28.7 24.3 19.7 15.0 - 25.9 4.5 25.9 25.9 23.6 19.0 14.4 - 62 27.1 3.9 27.1 27.1 26.7 22.1 17.4 12.8 24.9 4.4 24.9 24.9 24.7 20.1 15.5 10.8 57 27.8 3.9 27.8 27.8 27.8 23.2 18.6 13.9 25.6 4.4 25.6 25.6 25.6 21.0 16.3 11.7 72 31.9 3.7 29.7 24.5 19.4 14.2 - - 29.0 4.0 28.5 23.3 18.1 12.9 - - I 1350 67 28.8 3.8 28.8 28.8 25.4 20.2 15.0 - 26.0 4.3 26.0 26.0 24.4 19.2 14.0 - 62 27.1 3.9 27.1 27.1 27.1 21.9 16.8 11.6 25.0 4.2 25.0 25.0 25.0 19.8 14.6 9.4 57 27.9 3.8 27.9 27.9 27.9 22.7 17.5 12.3 25.7 4.1 25.7 25.7 25.7 20.5 15.3 10.1 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 32 Johnson Controls Unitary Products • 718444-YTG-H-0414 ....._._......._._.__............._.... DNQ042(3.5 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity' Input Return Dry Bulb(°F) Capacity.' Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 56.1 2.4 29.5 24.5 19.3 - - - 51.8 2.7 28.3 22.6 17.4 - - - 72 51.6 2.4 36.9 31.7 26.4 21.2 - - 48.1 2.7 35.3 30.1 24.8 19.6 - - 1225 67 47.2 2.4 44.3 38.9 33.6 28.4 23.1 - 44.4 2.7 42.4 37.5 32.3 27.0 21.8 - 62 42.1 2.3 42.1 41.8 36.7 31.4 26.2 20.9 40.5 2.7 40.5 40.3 36.9 31.7 26.4 21.2 57 42.9 2.4 42.9 42.9 39.8 34.5 29.3 24.1 40.0 2.7 40.0 40.0 37.5 32.3 27.0 21.8 77 56.2 2.4 31.6 26.1 20.2 - - - 52.9 2.7 31.1 24.4 18.5 - - - 72 51.8 2.4 39.5 33.6 27.7 21.9 - - 49.1 2.7 38.2 32.3 26.4 20.4 - - 1400 67 47.4 2.4 47.4 41.1 35.2 29.4 23.5 - 45.3 2.7 45.3 40.2 34.2 28.3 22.4 - 62 42.2 2.4 42.2 42.2 38.4 32.5 26.6 20.7 41.3 2.7 41.3 41.3 39.2 33.3 27.3 21.4 57 43.0 2.4 43.0 43.0 41.7 35.8 30.0 24.1 40.9 2.7 40.9 40.9 39.8 33.9 28.0 22.0 72 51.4 2.4 42.3 35.9 29.5 23.1 - - 48.9 2.7 41.0 34.6 28.1 21.6 - - 1575 67 46.9 2.4 46.9 43.8 37.5 31.1 24.7 - 45.1 2.7 45.1 42.5 36.5 30.1 23.6 - 62 41.8 2.4 41.8 41.8 39.9 33.5 27.1 20.7 41.1 2.7 41.1 41.1 40.1 33.6 27.1 20.7 57 42.6 2.4 42.6 42.6 42.0 35.6 29.2 22.8 40.7 2.7 40.7 40.7 40.2 33.7 27.2 20.8 72 50.9 2.4 45.1 38.2 31.3 24.4 - - 48.7 2.7 43.9 36.9 29.9 22.9 - - 1750 67 46.5 2.4 46.5 46.5 39.7 32.9 26.0 - 44.9 2.7 44.9 44.9 38.8 31.8 24.8 - 62 41.4 2.4 41.4 41.4 41.4 34.5 27.6 20.8 41.0 2.7 41.0 41.0 41.0 34.0 27.0 20.0 57 42.2 2.4 42.2 42.2 42.2 35.4 28.5 21.6 40.5 2.7 40.5 40.5 40.5 33.5 26.5 19.5 95°F 105°F 77 47.6 3.0 27.1 20.8 15.5 - - - 46.1 3.4 28.7 21.2 15.7 - - - 72 44.6 3.0 33.8 28.5 23.2 17.9 - - 42.6 3.4 33.6 28.2 22.9 17.5 - - 1225 67 41.5 3.0 40.4 36.2 30.9 25.6 20.4 - 39.0 3.3 38.5 35.2 30.0 24.6 19.3 - 62 38.8 3.0 38.8 38.8 37.2 31.9 26.7 21.4 37.4 3.3 37.4 37.0 34.4 29.1 23.7 18.4 57 37.2 3.0 37.2 37.2 35.3 30.0 24.7 19.4 35.4 3.3 35.4 35.4 33.5 28.1 22.8 17.4 77 49.6 3.0 30.7 22.7 16.7 - - - 47.2 3.4 33.2 23.1 16.8 - - - 72 46.4 3.0 36.9 31.0 25.0 19.0 - - 43.5 3.3 36.6 30.5 24.4 18.4 - - 1400 67 43.2 3.0 43.2 39.2 33.3 27.3 21.3 - 39.9 3.3 39.9 37.9 32.0 26.0 19.9 - 62 40.4 3.0 40.4 40.4 40.0 34.0 28.1 22.1 38.3 3.3 38.3 38.3 36.8 30.8 24.7 18.6 57 38.7 3.0 38.7 38.7 37.9 32.0 26.0 20.0 36.1 3.3 36.1 36.1 35.8 29.7 23.6 17.6 72 46.5 3.0 39.8 33.3 26.7 20.2 - - 43.9 3.4 39.3 32.7 26.1 19.5 - - 1575 67 43.3 3.0 43.3 41.3 35.6 29.0 22.5 - 40.3 3.3 40.3 39.3 34.2 27.6 20.9 - 62 40.5 3.0 40.5 40.5 40.3 33.7 27.2 20.6 38.6 3.3 38.6 38.6 37.9 31.3 24.7 18.1 57 38.8 3.0 38.8 38.8 38.4 31.8 25.3 18.7 36.5 3.3 36.5 36.5 36.3 29.7 23.1 16.4 72 46.5 3.0 42.7 35.6 28.4 21.3 - - 44.4 3.4 42.1 34.9 27.7 20.5 - - 1750 67 43.3 3.0 43.3 43.3 37.9 30.8 23.7 - 40.6 3.3 40.6 40.6 36.3 29.2 22.0 - 62 40.5 3.0 40.5 40.5 40.5 33.4 26.3 19.2 39.0 3.3 39.0 39.0 39.0 31.8 24.6 17.5 57 38.8 3.0 38.8 38.8 38.8 31.7 24.6 17.5 36.9 3.3 36.9 36.9 36.9 29.7 22.5 15.3 Johnson Controls Unitary Products 33 ) 718444-YTG-H-0414 ° , DNQ042(3.5 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) CFM WB Capacity/ Input Return Dry Bulb(°F) Capacity/ Input Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 115°F 125°F 77 44.7 3.7 30.2 21.6 16.0 - - - 43.2 4.1 32.3 23.0 16.2 - - - 72 40.6 3.7 33.4 27.9 22.5 17.1 - - 38.6 4.0 33.2 27.7 22.2 16.7 1225 67 36.5 3.7 36.5 34.3 29.0 23.6 18.2 - 34.0 4.0 34.0 33.3 28.1 22.6 17.1 - 62 36.1 3.7 36.1 35.3 31.7 26.3 20.8 15.4 34.7 4.0 34.7 33.5 28.9 23.4 17.9 12.4 57 33.6 3.7 33.6 33.6 31.7 26.2 20.8 15.4 31.8 4.0 31.8 31.8 29.8 24.3 18.8 13.3 77 44.7 3.7 35.8 23.5 17.0 - - - 42.2 4.1 38.4 25.9 17.1 - - - ¢ 72 40.6 3.7 36.2 30.0 23.9 17.8 - - 37.7 4.1 35.8 29.6 23.4 17.1 - - 1400 67 36.5 3.7 36.5 36.5 30.8 24.7 18.6 - 33.2 4.1 33.2 33.2 29.6 23.4 17.2 - 62 36.1 3.7 36.1 36.1 33.6 27.5 21.3 15.2 33.9 4.0 33.9 33.9 30.4 24.2 18.0 11.8 57 33.6 3.7 33.6 33.6 33.6 27.5 21.3 15.2 31.0 4.0 31.0 31.0 31.0 25.2 19.0 12.8 72 41.4 3.7 38.8 32.1 25.4 18.7 - - 38.9 4.1 38.3 31.6 24.8 18.0 - - 1575 67 37.3 3.7 37.3 37.3 32.8 26.1 19.4 - 34.2 4.1 34.2 34.2 31.4 24.7 17.9 - 62 36.8 3.7 36.8 36.8 35.6 28.9 22.2 15.5 35.0 4.0 35.0 35.0 33.2 26.5 19.7 12.9 57 34.2 3.7 34.2 34.2 34.2 27.6 20.9 14.2 32.0 4.0 32.0 32.0 32.0 25.4 18.7 11.9 72 42.2 3.7 41.5 34.2 27.0 19.7 - - 40.1 4.1 40.1 33.6 26.2 18.9 - - 1750 67 38.0 3.7 38.0 38.0 34.8 27.6 20.3 - 35.3 4.1 35.3 35.3 33.3 25.9 18.6 - 62 37.5 3.7 37.5 37.5 37.5 30.3 23.0 15.8 36.0 4.0 36.0 36.0 36.0 28.7 21.4 14.1 57 34.9 3.7 34.9 34.9 34.9 27.7 20.4 13.2 33.0 4.0 33.0 33.0 33.0 25.6 18.3 11.0 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 34 Johnson Controls Unitary Products y 718444-YTG-H-0414 DNQ048(4.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F - 77 58.8 2.6 31.6 26.4 20.6 -- - 2.6 40.1 34.3 28.5 22.7 52.2 3.0 31.9 25.9 20.1 72 55.0 5 .6 - - 3.0 39.6 33.8 27.9 22.0 - 1400 67 51.2 2.6 48.6 42.2 36.4 30.6 24.8 - 49.0 3.0 47.3 41.6 35.7 29.8 24.0 - 62 45.7 2.6 45.7 45.7 44.3 38.6 32.8 27.0 45.7 2.9 45.7 45.7 43.2 37.3 31.5 25.6 57 45.6 2.5 45.6 45.6 41.7 35.9 30.2 24.4 44.2 2.9 44.2 44.2 40.7 34.8 29.0 23.1 77 58.8 2.6 32.5 27.5 21.2 - - - 56.0 3.0 33.2 26.8 20.5 - - - 72 55.0 2.6 41.9 35.6 29.4 23.2 - - 52.4 3.0 41.0 34.8 28.5 22.3 - - 1500 67 51.2 2.6 51.2 43.8 37.6 31.4 25.2 - 48.8 3.0 48.8 42.8 36.5 30.3 24.0 - 1 62 45.7 2.6 45.7 45.7 45.7 39.6 33.4 27.2 45.5 3.0 45.5 45.5 44.2 38.0 31.7 25.5 57 45.6 2.5 45.6 45.6 43.1 36.9 30.7 24.5 44.1 2.9 44.1 44.1 41.6 35.4 29.1 22.9 1 72 55.0 2.6 44.3 37.6 30.9 24.2 - - 52.0 3.0 43.4 36.7 29.9 23.2 - - 1650 67 51.2 2.6 51.2 46.7 39.5 32.8 26.1 - 48.5 3.0 48.5 45.1 38.3 31.6 24.8 - 62 45.7 2.6 45.7 45.7 45.7 39.1 32.4 25.7 45.2 3.0 45.2 45.2 44.5 37.8 31.0 24.2 57 45.6 2.5 45.6 45.6 44.3 37.6 30.9 24.2 43.8 2.9 43.8 43.8 42.5 35.8 29.0 22.2 72 54.9 2.6 46.7 39.6 32.4 25.2 - - 51.6 3.0 45.9 38.6 31.3 24.0 - - 1800 67 51.1 2.6 51.1 49.7 41.4 34.2 27.0 - 48.1 3.0 48.1 47.4 40.1 32.8 25.6 - 62 45.7 2.6 45.7 45.7 45.7 38.5 31.4 24.2 44.8 2.9 44.8 44.8 44.8 37.6 30.3 23.0 57 45.6 2.5 45.6 45.6 45.6 38.4 31.2 24.0 43.4 2.9 43.4 43.4 43.4 36.2 28.9 21.6 95°F 105°F 77 53.5 3.4 32.2 25.5 19.6 - - - 50.4 3.8 32.6 24.5 18.5 - - - 72 50.2 3.3 39.2 33.2 27.3 21.4 - - 47.3 3.8 38.3 32.2 26.2 20.2 - - 1400 67 46.8 3.3 46.1 41.0 35.0 29.1 23.1 - 44.3 3.8 43.9 40.0 34.0 27.9 21.9 - 62 45.6 3.3 45.6 45.6 42.1 36.1 30.2 24.3 43.6 3.7 43.6 43.2 39.0 33.0 27.0 20.9 57 42.9 3.3 42.9 42.9 39.6 33.7 27.8 21.8 42.5 3.7 42.5 42.1 38.0 32.0 26.0 20.0 77 53.1 3.4 33.9 26.1 19.8 - - - 49.9 3.8 35.2 25.2 18.8 - - - i 72 49.8 3.3 40.2 33.9 27.6 21.4 - - 46.8 3.8 39.5 33.1 26.7 20.3 - - 1500 67 46.4 3.3 46.4 41.7 35.5 29.2 22.9 - 43.8 3.7 43.8 41.0 34.6 28.2 21.8 - 62 45.2 3.3 45.2 45.2 42.6 36.3 30.1 23.8 43.1 3.7 43.1 43.1 39.7 33.3 26.9 20.5 57 42.5 3.3 42.5 42.5 40.1 33.9 27.6 21.3 42.0 3.7 42.0 42.0 38.7 32.3 25.9 19.5 72 49.1 3.3 42.6 35.8 28.9 22.1 - - 45.8 3.8 41.3 34.7 27.8 20.9 - - 1650 67 45.7 3.3 45.7 43.4 37.1 30.3 23.5 - 42.8 3.7 42.8 41.4 36.0 29.1 22.1 - 62 44.6 3.3 44.6 44.6 43.3 36.5 29.6 22.8 42.2 3.7 42.2 42.2 40.4 33.5 26.6 19.6 57 41.9 3.3 41.9 41.9 40.7 33.9 27.1 20.3 41.1 3.7 41.1 41.1 39.4 32.5 25.5 18.6 72 48.3 3.3 45.0 37.6 30.2 22.9 - - 44.8 3.8 43.1 36.4 28.9 21.5 - - 1800 67 45.1 3.3 45.1 45.1 38.8 31.5 24.1 - 41.9 3.7 41.9 41.9 37.5 30.0 22.5 - 62 44.0 3.3 44.0 44.0 44.0 36.6 29.2 21.8 41.2 3.7 41.2 41.2 41.2 33.7 26.3 18.8 57 41.3 3.3 41.3 41.3 41.3 33.9 26.6 19.2 40.1 3.7 40.1 40.1 40.1 32.6 25.2 17.7 Johnson Controls Unitary Products 35 718444-YTG-H-0414 ` DNQ048(4.0 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 115°F 125°F 77 47.2 4.2 32.9 23.5 17.4 - - - 44.1 4.6 33.6 23.0 16.4 - - - 72 44.5 4.2 37.4 31.3 25.2 19.1 - - 41.7 4.6 36.4 30.3 24.1 17.9 - - 1400 67 41.8 4.2 41.8 39.0 32.9 26.8 20.7 - 39.3 4.6 39.3 38.0 31.8 25.6 19.5 - 62 41.5 4.2 41.5 40.8 35.9 29.8 23.7 17.6 39.5 4.6 39.5 38.5 32.8 26.6 20.5 14.3 57 42.0 4.2 42.0 41.4 36.4 30.3 24.2 18.1 41.6 4.6 41.6 40.6 34.8 28.6 22.5 16.3 77 46.6 4.2 36.4 24.4 17.9 - - - 43.4 4.6 37.7 24.3 16.9 - 72 43.9 4.2 38.8 32.3 25.8 19.2 - - 41.0 4.6 38.2 31.5 24.8 18.2 1500 67 41.2 4.2 41.2 40.2 33.7 27.1 20.6 - 38.6 4.6 38.6 38.6 32.8 26.1 19.4 - 62 41.0 4.1 41.0 41.0 36.8 30.2 23.7 17.2 38.8 4.6 38.8 38.8 33.8 27.2 20.5 13.8 57 41.5 4.1 41.5 41.5 37.3 30.8 24.2 17.7 41.0 4.6 41.0 41.0 35.9 29.2 22.5 15.9 72 42.6 4.2 40.0 33.7 26.7 19.6 - - 39.3 4.6 38.7 32.7 25.6 18.4 - - 1650 67 39.9 4.2 39.9 39.4 34.9 27.8 20.8 - 37.0 4.6 37.0 37.0 33.7 26.6 19.4 62 39.7 4.2 39.7 39.7 37.6 30.5 23.5 16.4 37.3 4.6 37.3 37.3 34.8 27.6 20.4 13.3 57 40.2 4.1 40.2 40.2 38.1 31.1 24.0 17.0 39.3 4.6 39.3 39.3 36.8 29.6 22.5 15.3 72 41.2 4.2 41.2 35.2 27.6 20.1 - - 37.6 4.6 37.6 34.0 26.3 18.6 - - 67 38.7 4.2 38.7 38.7 36.1 28.5 21.0 - 35.4 4.6 35.4 35.4 34.7 27.1 19.4 - 1800 62 38.4 4.2 38.4 38.4 38.4 30.9 23.3 15.7 35.7 4.6 35.7 35.7 35.7 28.0 20.4 12.7 57 38.9 4.2 38.9 38.9 38.9 31.4 23.8 16.2 37.7 4.6 37.7 37.7 37.7 30.1 22.4 14.7 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 36 Johnson Controls Unitary Products -40 718444-YTG-H-0414 . DNQ060(5.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (SF) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 i 75°F 85°F 77 66.9 3.3 34.4 28.0 21.6 - - - 65.1 3.7 32.9 26.6 20.2 - - - 72 61.6 3.2 43.2 36.8 30.4 24.0 - - 60.4 3.7 42.3 36.0 29.6 23.3 - - 1550 67 56.2 3.2 52.1 45.7 39.3 32.9 26.5 - 55.7 3.6 51.7 45.4 39.0 32.7 26.3 - 62 51.9 3.2 51.9 51.9 47.1 40.7 34.3 27.8 51.4 3.6 51.4 51.4 45.6 39.3 32.9 26.6 57 51.4 3.2 51.4 51.4 47.5 41.1 34.7 28.3 50.8 3.6 50.8 50.8 45.7 39.4 33.0 26.7 77 71.0 3.3 36.0 30.4 23.8 67.6 3.7 35.5 28.8 22.1 ( 72 65.4 3.2 46.8 40.1 33.5 26.8 - - 62.7 3.7 45.7 39.0 32.4 25.7 - - 1650 67 59.7 3.2 57.6 49.8 43.2 36.5 29.8 - 57.9 3.6 55.9 49.3 42.6 36.0 29.3 - 62 55.1 3.2 55.1 55.1 51.7 45.0 38.4 31.7 53.3 3.6 53.3 53.3 49.9 43.2 36.6 29.9 I 57 54.5 3.2 54.5 54.5 52.2 45.6 38.9 32.2 52.7 3.6 52.7 52.7 50.0 43.3 36.7 30.0 ' 77 75.1 3.3 37.6 32.8 25.9 - - - 70.1 3.7 38.0 30.9 24.0 - - - 72 69.1 3.2 50.4 43.4 36.5 29.5 - - 65.0 3.7 49.0 42.1 35.1 28.2 - - 1 1750 67 63.2 3.2 63.2 54.0 47.1 40.1 33.1 - 60.0 3.6 60.0 53.2 46.3 39.3 32.4 - 62 58.3 3.2 58.3 58.3 56.4 49.4 42.5 35.5 55.3 3.6 55.3 55.3 54.1 47.2 40.2 33.3 57 57.7 3.2 57.7 57.7 57.0 50.0 43.0 36.1 54.7 3.6 54.7 54.7 54.2 47.3 40.3 33.4 1 72 69.3 3.2 51.8 44.2 36.7 29.1 - - 65.0 3.7 50.3 42.6 34.8 27.0 - - r 2000 67 63.4 3.2 63.4 54.9 47.3 39.8 32.2 - 59.9 3.6 59.9 53.6 45.8 38.0 30.2 - 62 58.5 3.2 58.5 58.5 56.7 49.1 41.6 34.0 55.2 3.6 55.2 55.2 53.6 45.8 38.0 30.2 d 57 57.9 3.2 57.9 57.9 57.2 49.7 42.1 34.6 54.6 3.6 54.6 54.6 53.7 45.9 38.1 30.3 f 95°F 105°F 77 63.3 4.1 31.4 25.1 18.8 - - - 59.3 4.4 36.6 29.5 23.1 - - - 72 59.2 4.1 41.4 35.1 28.8 22.5 - - 55.2 4.5 42.9 36.5 30.1 23.7 - - 1550 67 55.2 4.1 51.4 45.1 38.8 32.4 26.1 - 51.1 4.6 49.1 43.5 37.1 30.7 24.3 - 62 50.8 4.0 50.8 50.5 44.2 37.9 31.6 25.3 47.4 4.5 47.4 47.3 44.2 37.7 31.3 24.9 57 50.2 4.0 50.2 50.2 43.9 37.6 31.3 25.0 47.3 4.4 47.3 47.3 44.1 37.7 31.3 24.9 77 64.2 4.1 34.9 27.1 20.5 - - - 60.1 4.5 39.1 30.7 23.8 - - - 72 60.1 4.1 44.5 37.9 31.3 24.7 - - 55.9 4.6 45.0 38.1 31.2 24.4 - - 1650 67 56.0 4.1 54.1 48.7 42.1 35.5 28.9 - 51.8 4.6 50.8 45.5 38.6 31.8 24.9 - 62 51.5 4.0 51.5 51.4 48.1 41.4 34.8 28.2 48.1 4.5 48.1 48.0 46.4 39.5 32.6 25.8 57 50.9 4.0 50.9 50.9 47.7 41.1 34.5 27.8 47.9 4.5 47.9 47.9 46.3 39.5 32.6 25.8 77 65.1 4.1 38.4 29.0 22.1 - - - 60.9 4.6 41.5 31.9 24.6 - - - 72 60.9 4.1 47.6 40.7 33.8 26.8 - - 56.7 4.6 47.0 39.7 32.4 25.1 - - 1750 67 56.8 4.1 56.8 52.4 45.4 38.5 31.6 - 52.5 4.7 52.5 47.5 40.2 32.9 25.6 - 62 52.2 4.0 52.2 52.2 51.9 44.9 38.0 31.1 48.8 4.6 48.8 48.8 48.6 41.3 34.0 26.7 57 51.6 4.0 51.6 51.6 51.5 44.6 37.6 30.7 48.6 4.5 48.6 48.6 48.5 41.2 33.9 26.6 72 60.6 4.1 48.9 40.9 32.9 24.8 - - 56.5 4.5 50.6 42.6 34.6 26.6 - - 2000 67 56.5 4.0 56.5 52.2 44.2 36.2 28.2 - 52.3 4.6 52.3 50.2 42.6 34.6 26.6 - 62 52.0 4.0 52.0 52.0 50.5 42.5 34.5 26.4 48.6 4.4 48.6 48.6 47.8 39.8 31.8 23.8 57 51.4 4.0 51.4 51.4 50.1 42.1 34.1 26.1 48.4 4.4 48.4 48.4 47.8 39.8 31.8 23.7 j 1 ) s Johnson Controls Unitary Products 37 718444-YTG-H-0414 I DNQ060(5.0 Ton)(Continued) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) CFM (°F) (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 115°F 125°F 77 55.3 4.8 41.8 33.9 27.3 - - - 51.3 5.1 49.0 38.2 31.6 - - - 72 51.1 5.0 44.4 37.9 31.4 24.9 - - 47.0 5.4 45.9 39.3 32.6 26.0 - - 1550 67 46.9 5.1 46.9 41.9 35.4 28.9 22.4 - 42.8 5.7 42.8 40.3 33.7 27.1 20.5 - 62 44.1 4.9 44.1 44.1 44.1 37.6 31.0 24.5 40.7 5.3 40.7 40.7 40.7 37.4 30.7 24.1 57 44.4 4.8 44.4 44.4 44.4 37.8 31.3 24.8 41.4 5.1 41.4 41.4 41.4 38.0 31.4 24.7 77 56.0 4.9 43.2 34.3 27.2 - - - 52.0 5.3 48.3 37.9 30.6 - - - 72 51.8 5.1 45.4 38.3 31.2 24.1 - - 47.7 5.5 45.9 38.5 31.2 23.8 - - 1650 67 47.6 5.2 47.6 42.3 35.2 28.1 21.0 - 43.4 5.8 43.4 39.1 31.8 24.4 17.1 - 62 44.7 5.0 44.7 44.7 44.7 37.6 30.5 23.4 41.3 5.5 41.3 41.3 41.3 35.6 28.3 21.0 57 45.0 4.9 45.0 45.0 45.0 37.9 30.8 23.7 42.0 5.3 42.0 42.0 42.0 36.3 28.9 21.6 77 56.8 5.0 44.6 34.8 27.1 - - - 52.7 5.4 47.7 37.6 29.6 - - - 72 52.5 5.2 46.4 38.7 31.0 23.3 - - 48.3 5.7 45.8 37.8 29.7 21.6 - - 1750 67 48.2 5.3 48.2 42.7 35.0 27.3 19.6 - 43.9 6.0 43.9 37.9 29.8 21.7 13.7 - 62 45.3 5.1 45.3 45.3 45.3 37.6 29.9 22.2 41.8 5.7 41.8 41.8 41.8 33.9 25.8 17.8 57 45.6 5.0 45.6 45.6 45.6 37.9 30.2 22.5 42.6 5.4 42.6 42.6 42.6 34.6 26.5 18.4 72 52.4 4.9 52.4 44.4 36.3 28.3 - - 48.3 5.3 48.3 46.1 38.1 30.1 - - 2000 67 48.1 5.1 48.1 48.1 41.0 33.0 25.0 - 44.0 5.6 44.0 44.0 39.4 31.4 23.3 - 62 45.2 4.9 45.2 45.2 45.2 37.2 29.2 21.1 41.8 5.3 41.8 41.8 41.8 34.5 26.5 18.5 57 45.5 4.7 45.5 45.5 45.5 37.5 29.5 21.4 42.6 5.1 42.6 42.6 42.6 35.2 27.1 19.1 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 38 Johnson Controls Unitary Products 718444-YTG-H-0414 DNX024-048 Cooling Capacities DNX024(2.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) Net Total Sensible Capacity(MBh) CFM WB Capacity1 Input Return Dry Bulb(°F) - Capacity1 Input Return Dry Bulb(°F) (°F) (MBh) (kW) 90 1 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 1 75 I 70 I 65 75°F 85°F 77 24.9 1.2 11.4 8.7 9.0 23.6 1.3 11.9 10.1 8.3 - - 72 22.8 1.1 16.1 13.0 11.8 9.7 - - 21.4 1.3 15.6 13.4 11.2 9.0 - - 600 67 20.8 1.1 20.8 17.3 14.7 12.1 9.5 - 19.2 1.3 19.2 16.7 14.0 11.4 8.7 - 62 18.3 1.1 18.3 18.3 17.7 13.7 9.8 5.8 17.2 1.3 17.2 17.2 16.9 12.8 8.8 4.7 57 19.5 1.0 19.5 19.5 19.4 15.1 10.9 6.6 17.8 1.2 17.8 17.8 17.7 13.5 9.3 5.1 77 32.1 1.8 15.1 13.3 10.8 - - - 30.6 2.0 15.6 12.9 10.3 - - - 72 29.8 1.8 21.1 18.2 15.3 12.4 - - 28.2 1.9 20.6 17.6 14.6 11.6 - - 800 67 27.4 1.7 27.1 23.0 19.7 16.5 13.2 - 25.7 1.9 25.5 22.2 18.9 15.7 12.4 - 62 25.0 1.7 25.0 25.0 24.2 20.8 17.4 14.0 23.6 1.8 23.6 23.6 23.1 19.7 16.2 12.8 57 25.6 1.7 25.6 25.6 25.6 21.9 18.1 14.3 23.9 1.9 23.9 23.9 23.7 20.1 16.5 12.9 95°F 105°F 77 22.3 1.5 12.5 11.4 7.6 - - - 20.1 1.7 13.0 8.7 6.8 - - - 72 19.9 1.5 15.1 13.7 10.5 8.2 - - 18.0 1.7 14.5 11.4 9.8 7.4 - - 600 67 17.6 1.4 17.6 16.0 13.4 10.7 8.0 - 15.9 1.6 15.9 14.1 12.7 9.1 5.6 - 62 16.1 1.4 16.1 16.1 16.1 11.9 7.7 3.6 14.6 1.6 14.6 14.6 15.1 10.8 5.9 2.3 57 16.1 1.4 16.1 16.1 15.9 11.8 7.7 3.6 14.9 1.6 14.9 14.7 14.6 11.2 7.8 4.3 77 29.2 2.1 16.1 12.5 9.8 - - - 26.9 2.4 17.0 11.9 9.0 - - - 72 26.6 2.1 20.1 17.0 14.0 10.9 - - 24.4 2.3 19.4 16.3 13.2 10.0 - - 800 67 24.0 2.1 24.0 21.5 18.2 14.8 11.5 - 21.9 2.3 21.9 20.7 17.3 13.9 10.5 - 62 22.2 2.0 22.2 22.2 22.1 18.6 15.1 11.5 20.3 2.3 20.3 20.3 21.0 17.4 13.8 10.1 57 22.2 2.0 22.2 22.2 21.7 18.3 14.9 11.5 20.7 2.3 20.7 20.7 20.1 16.6 13.1 9.6 115°F 77 18.0 1.9 13.5 6.0 6.0 - - - 72 16.1 1.9 13.9 9.0 9.0 6.6 - - 600 67 14.3 1.8 14.3 12.1 12.1 7.6 3.1 - 62 13.1 1.8 13.1 13.1 14.1 9.7 4.1 1.0 57 13.8 1.8 13.8 13.3 13.3 10.5 7.8 5.1 77 24.5 2.6 17.8 11.4 8.3 - - - 72 22.2 2.6 18.8 15.6 12.4 9.1 - - 800 67 19.8 2.5 19.8 19.8 16.5 13.0 9.4 - 62 18.5 2.5 18.5 18.5 19.9 16.2 12.5 8.7 57 19.2 2.5 19.2 19.2 18.5 14.9 11.3 7.6 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. Johnson Controls Unitary Products 39 V! 718444-YTG-H-0414 • DNX036(3.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) _ Net Total Sensible Capacity(MBh) CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) (kW)2 90 I 85 I 80 1 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 35.2 1.5 20.9 13.3 11.6 - - - 33.3 1.7 21.2 15.1 11.3 - - - 72 32.3 1.5 25.2 20.0 17.0 12.9 - - 30.4 1.7 24.4 20.3 16.3 12.3 - - 925 67 29.5 1.5 29.5 26.8 22.4 18.1 13.8 - 27.5 1.7 27.5 25.5 21.4 17.2 13.0 - 62 26.8 1.5 26.8 26.8 27.2 22.5 17.8 13.2 25.1 1.7 25.1 25.1 25.1 20.8 16.5 12.2 57 28.2 1.6 28.2 28.2 25.4 21.2 17.0 12.8 25.9 1.8 25.9 25.9 24.2 20.0 15.9 11.7 77 48.7 2.8 23.8 19.3 14.7 - - - 46.5 3.0 25.5 19.4 14.7 - - - 72 45.7 2.6 33.3 28.3 23.2 18.2 - - 43.2 2.9 32.7 27.6 22.5 17.3 - - 1275 67 42.8 2.5 42.8 37.2 31.7 26.1 20.6 - 39.9 2.8 39.9 35.8 30.2 24.6 19.0 - 62 38.0 2.3 38.0 38.0 34.6 29.8 24.9 20.0 36.7 2.6 36.7 36.7 34.0 28.7 23.5 18.3 57 38.4 2.5 38.4 38.4 35.9 30.3 24.7 19.1 36.7 2.8 36.7 36.7 34.4 28.8 23.1 17.5 95°F 105°F 77 31.5 1.9 21.5 17.0 11.0 - - - 29.0 2.2 21.9 13.1 10.1 - - - 72 28.5 1.9 23.6 20.7 15.6 11.7 - - 26.2 2.2 22.7 17.3 14.8 10.9 - - 925 67 25.6 1.9 25.6 24.3 20.3 16.2 12.2 - 23.4 2.2 23.4 21.5 19.5 15.4 11.3 - 62 23.4 1.9 23.4 23.4 23.0 19.1 15.1 11.2 21.5 2.2 21.5 21.5 21.3 17.3 12.3 9.4 57 23.6 1.9 23.6 23.6 22.9 18.8 14.8 10.7 22.3 2.2 22.3 21.6 21.3 17.2 13.2 9.2 77 44.4 3.2 27.2 19.4 14.7 - - - 41.3 3.5 27.9 18.8 13.7 - - - 72 40.7 3.1 32.1 26.9 21.7 16.5 - - 37.8 3.4 31.1 25.9 20.7 15.4 - - 1275 67 37.0 3.1 37.0 34.3 28.7 23.1 17.4 - 34.3 3.4 34.3 33.0 27.6 22.0 16.3 - 62 35.4 2.9 35.4 35.4 33.3 27.7 22.1 16.5 32.4 3.3 32.4 32.4 31.4 25.6 19.8 14.1 57 35.0 3.0 35.0 35.0 32.9 27.2 21.6 15.9 33.0 3.3 33.0 33.0 31.1 25.4 19.6 13.9 115°F 77 26.5 2.4 22.3 9.2 9.2 - - - 72 23.9 2.4 21.8 14.0 14.0 10.1 - - 925 67 21.3 2.4 21.3 18.7 18.7 14.6 10.4 - 62 19.6 2.4 19.6 19.6 19.6 15.6 9.6 7.7 57 21.0 2.4 21.0 19.7 19.7 15.7 11.7 7.6 77 38.3 3.8 28.6 18.1 12.8 - - - 72 35.0 3.8 30.2 24.9 19.6 14.4 - - 1275 67 31.7 3.7 31.7 31.7 26.5 20.8 15.2 - 62 29.5 3.6 29.5 29.5 29.5 23.5 17.6 11.6 57 30.9 3.6 30.9 30.9 29.4 23.5 17.7 11.8 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. 40 Johnson Controls Unitary Products 718444-YTG-H-0414 DNX048(4.0 Ton) Air on Temperature of Air on Condenser Coil Evaporator Coil Net Total Sensible Capacity(MBh) _ Net Total Sensible Capacity(MBh) CFM WB Capacity Input Return Dry Bulb(°F) Capacity Input Return Dry Bulb(°F) (°F) (MBh) fkW/2 90 I 85 I 80 I 75 I 70 I 65 (MBh) (kW)2 90 I 85 I 80 I 75 I 70 I 65 75°F 85°F 77 45.3 2.2 23.2 17.3 14.8 - - - 42.8 2.5 22.7 18.4 14.2 - - - 72 42.0 2.2 29.7 24.2 20.6 16.0 - - 39.6 2.5 28.9 24.3 19.8 15.2 - - 1000 67 38.8 2.2 36.3 31.1 26.3 21.5 16.7 - 36.4 2.5 35.1 30.2 25.3 20.5 15.6 62 34.4 2.2 34.4 34.4 31.7 27.3 22.8 18.4 32.4 2.5 32.4 32.4 30.7 26.2 21.7 17.2 57 33.6 2.2 33.6 33.6 33.0 28.4 23.8 19.2 31.7 2.4 31.7 31.7 31.2 26.6 21.9 17.3 77 64.7 3.9 31.1 26.6 20.8 60.7 4.2 31.0 25.2 19.4 72 59.6 3.8 42.0 35.7 29.4 23.2 - - 56.0 4.1 40.7 34.4 28.1 21.7 - - 'p 1550 67 54.5 3.7 52.9 44.9 38.1 31.2 24.4 - 51.2 4.0 50.4 43.6 36.8 29.9 23.1 - 62 50.3 3.5 50.3 50.3 46.3 39.4 32.4 25.5 47.6 3.8 47.6 47.6 44.4 37.5 30.5 23.6 57 48.8 3.5 48.8 48.8 48.3 41.5 34.7 27.9 46.5 3.7 46.5 46.5 46.3 39.3 32.3 25.4 t 95°F 105°F ) 77 40.4 2.8 22.2 19.6 13.5 - - - 37.5 3.1 23.2 15.4 12.4 - 1 72 37.2 2.8 28.1 24.4 18.9 14.4 - - 34.3 3.1 27.2 20.6 17.9 13.2 1000 67 34.0 2.8 34.0 29.3 24.4 19.4 14.4 - 31.1 3.1 31.1 25.8 23.3 18.6 13.8 - ) 62 30.5 2.7 30.5 30.5 29.6 25.0 20.5 15.9 28.0 3.1 28.0 28.0 27.7 23.1 18.1 13.8 1 57 29.8 2.7 29.8 29.8 29.4 24.7 20.0 15.4 28.0 3.0 28.0 27.9 27.7 22.8 17.9 13.0 77 56.8 4.5 30.9 23.8 17.9 - - - 52.1 4.9 32.0 22.7 16.7 - - - 72 52.4 4.4 39.4 33.1 26.7 20.3 - - 48.4 4.7 38.4 31.9 25.5 19.0 - - 1550 67 48.0 4.3 48.0 42.3 35.5 28.6 21.8 - 44.8 4.6 44.8 41.2 34.2 27.2 20.2 - 62 44.8 4.1 44.8 44.8 42.6 35.6 28.6 21.6 42.0 4.4 42.0 42.0 40.4 33.4 26.4 19.3 57 44.3 4.0 44.3 44.3 44.3 37.1 30.0 22.8 41.9 4.4 41.9 41.9 41.0 33.9 26.7 19.6 115°F 77 34.7 3.5 24.2 11.2 11.2 - - - 72 31.5 3.5 26.2 16.8 16.8 12.0 - - 1000 67 28.2 3.4 28.2 22.3 22.3 17.8 13.3 - 1 62 25.4 3.4 25.4 25.4 25.8 21.1 15.8 11.7 57 26.3 3.4 26.3 25.9 25.9 20.9 15.8 10.7 77 47.4 5.3 33.2 21.6 15.5 - - - 72 44.5 5.1 37.4 30.8 24.2 17.6 - - 1550 67 41.6 5.0 41.6 40.0 32.9 25.8 18.7 - 62 39.2 4.8 39.2 39.2 38.2 31.2 24.1 17.0 57 39.4 4.8 39.4 39.4 37.8 30.6 23.5 16.3 1. These capacities are Net Capacities. 2. These ratings include the compressor,condenser fan and supply air blower motors. Johnson Controls Unitary Products 41 t3, 718444-YTG-H-0414 Airflow Performance DNZ Side Duct Application External Static Pressure(Inch Water Gauge) Model Unit Speed 0.2 0.4 0.6 0.8 1.0 (Tons) SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM Low(1) 719 115 752 617 130 858 - - - - - - - - - DNZ024 Low/Medium(2) 781 137 789 691 155 891 - - - - - - - - - (2.0) Medium(3) 902 187 858 824 207 949 734 223 1037 622 230 1116 - - - Medium/High(4) - - - 937 258 998 845 270 1075 722 271 1146 - - - High(5) - - - - - - 933 316 1104 796 307 1162 - - - Low(1) 827 163 825 759 187 919 - - - - - - - - - DNZ030 Low/Medium(2) 988 251 914 916 269 992 831 282 1067 - - - - - - (2.5) Medium(3) 1113 322 984 1035 333 1047 941 337 1108 818 329 1162 - - - Medium/High(4) 1233 394 1050 1145 394 1099 1040 388 1145 901 367 1184 - - - High(5) - - - - - - 1078 425 1164 867 353 1173 - - - Low(1) 1032 236 789 921 258 853 - - - - - - - - - DNZ036 Low/Medium(2) 1185 317 859 1089 347 924 985 373 991 - - - - - - (3.0) Medium(3) 1304 395 913 1214 424 978 1114 448 1040 994 462 1098 - - - Medium/High(4) 1445 515 976 1357 532 1041 1252 542 1097 1117 537 1140 - - - High(5) - - - 1498 708 1108 1363 665 1157 1179 599 1178 - - - Low(1) 1114 176 642 - - - - - - - - - - - - DNZ042 Low/Medium(2) 1223 230 679 1056 264 773 - - - - - - - - - (3.5) Medium(3) 1641 404 751 1418 460 872 1288 492 942 1187 518 997 1101 540 1044 Medium/High(4) - - - 1535 547 904 1398 582 976 1292 606 1030 1203 624 1074 High(5) - - - 1665 664 940 1514 701 1015 1399 720 1067 1304 729 1106 Low(1) 1378 310 749 1209 343 840 - - - - - - - - - DNZ048 Low/Medium(2) 1414 331 763 1253 366 851 - - - - - - - - - (4.0) Medium(3) 1713 544 872 1604 587 940 1484 624 1005 1343 653 1067 - - - Medium/High(4) 1882 703 931 1786 740 987 1671 769 1044 1522 783 1099 1231 717 1142 High(5) - - - 1972 946 1037 1851 949 1078 1689 927 1118 1306 759 1142 Low(1) 1556 416 802 - - - - - - - - - - - - DNZ060 Low/Medium(2) 1648 489 843 1522 529 917 - - - - - - - - - (5.0) Medium(3) 1767 595 892 1664 633 954 1546 668 1015 - - - - - - Medium/High(4) 1913 739 946 1819 769 996 1702 791 1049 1550 800 1102 - - - High(5) 2103 952 1007 1990 957 1047 1855 948 1086 1674 912 1122 - - - DNZ Bottom Duct Application Model External Static Pressure(Inch Water Gauge) (Tons) Unit Speed 0.2 0.4 0.6 0.8 1.0 SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM Low(1) 719 115 752 617 130 858 - - - - - - - - - DNZ024 Low/Medium(2) 781 137 789 691 155 891 - - - - - - - - - (2.0) Medium(3) 902 187 858 824 207 949 734 223 1037 622 230 1116 - - - Medium/High(4) - - - 937 258 998 . 845 270 1075 722 271 1146 - - - High(5) - - - - - - 933 316 1104 796 307 1162 - - - Low(1) 827 163 825 759 187 919 - - - - - - - - - DNZ030 Low/Medium(2) 988 251 914 916 269 992 831 282 1067 - - - - - - (2."5) Medium(3) 1113 322 984 1035 333 1047 941 337 1108 818 329 1162 - - - Medium/High(4) 1233 394 1050 1145 394 1099 1040 388 1145 901 367 1184 - - - High(5) - - - - - - 1078 425 1164 867 353 1173 - - - Low(1) 1032 236 789 921 258 853 - - - - - - - - - DNZ036 Low/Medium(2) 1185 317 859 1089 347 924 985 373 991 - - - - - - (3.0) Medium(3) 1304 395 913 1214 424 978 1114 448 1040 994 462 1098 - - - Medium/High(4) 1445 515 976 1357 532 1041 1252 542 1097 1117 537 1140 - - - High(5) - - - 1498 708 1108 1363 665 1157 1179 599 1178 - - - Low(1) 1114 176 642 - - - - - - - - - - - - DNZ042 Low/Medium(2) 1223 230 679 1056 264 773 - - - - - - - - - (3.5) Medium(3) 1641 404 751 1418 460 872 1288 492 942 1187 518 997 1101 540 1044 Medium/High(4) - - - 1535 547 904 1398 582 976 1292 606 1030 1203 624 1074 High(5) - - - 1665 664 940 1514 701 1015 1399 720 1067 1304 729 1106 Low(1) 1378 310 749 1209 343 840 - - - - - - - - - DNZ048 Low/Medium(2) 1414 331 763 1253 366 851 - - - - - - - - - (4.0) Medium(3) 1713 544 872 1604 587 940 1484 624 1005 1343 653 1067 - - - Medium/High(4) 1882 703 931 1786 740 987 1671 769 1044 1522 783 1099 1231 717 1142 High(5) - - - 1972 946 1037 1851 949 1078 1689 927 1118 1306 759 1142 Low(1) 1556 416 802 - - - - - - - - - - - - DNZ060 Low/Medium(2) 1648 489 843 1522 529 917 - - - - - - - - - (5.0) Medium(3) 1767 595 892 1664 633 954 1546 668 1015 - - - - - - Medium/High(4) 1913 739 946 1819 769 996 1702 791 1049 1550 800 1102 - - - High(5) 2103 952 1007 1990 957 1047 1855 948 1086 1674 912 1122 - - - 42 Johnson Controls Unitary Products 718444-YTG-H-0414 DNQ Side Duct Application Model Thermostat Speed External Static Pressure(Inch Water Gauge) (Tons) Mode Input Tap CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 800 177 204 232 261 290 320 350 382 414 Cool High Y1 COOL-B 600 100 122 145 169 194 221 249 279 310 Y1 COOL-C 700 134 159 184 211 238 265 293 323 352 Y1 COOL-D 900 229 258 288 319 351 385 420 457 494 W1 HEAT-A 670 123 147 172 197 224 251 - - - N036 W1 HEAT-B 730 146 172 198 225 252 280 - - - W1 HEAT-C 790 173 199 227 255 284 314 - - - W1 HEAT-D 850 202 230 259 289 319 351 - - - W1 HEAT-A 940 253 281 312 344 378 - - - - DNQ024 N056 W1 HEAT-B 975 274 303 334 368 403 - - - - (2.0) W1 HEAT-C 1000 290 319 351 385 422 - - - - Heat W1 HEAT-D 1050 324 353 386 422 461 - - - - W1 HEAT-A 670 123 147 172 197 224 - - - - W1 HEAT-B 690 130 155 180 206 233 - - - - W1 HEAT-C 710 138 163 189 215 242 - - - - D056 W1 HEAT-D 750 155 181 207 235 262 - - - - W1+W2 HEAT-A 940 253 281 312 344 378 - - - - W1+W2 HEAT-B 970 271 300 331 364 400 - - - - W1+W2 HEAT-C 1000 290 319 351 385 422 - - - - W1+W2 HEAT-D 1050 324 353 386 422 461 - - - - Y1 COOL-A 900 222 254 291 323 340 381 431 462 516 Cool High Y1 COOL-B 1000 271 306 360 397 433 469 508 554 571 Y1 COOL-C 1125 367 411 445 500 533 588 625 647 665 Y1 COOL-D 1250 472 522 587 628 660 686 701 720 736 W1 HEAT-A 670 121 152 180 205 228 257 - - - N036 W1 HEAT-B 730 143 180 204 225 260 286 - - - W1 HEAT-C 790 172 205 237 267 296 329 - - - W1 HEAT-0 850 195 235 263 310 324 366 - - - W1 HEAT-A 1050 297 341 385 427 469 - - - - DNQ030 N056 W1 HEAT-B 1135 379 417 455 496 536 - - - - (2.5) W1 HEAT-C 1220 448 493 537 586 635 - - - - Heat W1 HEAT-D 1300 514 562 610 655 700 - - - - W1 HEAT-A 680 130 161 189 214 237 - - - - W1 HEAT-B 735 150 185 212 229 269 - - - - W1 HEAT-C 790 172 205 237 267 296 - - - - D056 W1 HEAT-D 840 204 244 272 319 333 - - - - W1+W2 HEAT-A 1050 297 341 385 427 469 - - - - W1+W2 HEAT-B 1135 379 417 455 496 536 - - - - W1+W2 HEAT-C 1220 448 493 537 586 635 - - - - W1+W2 HEAT-D 1300 514 562 610 655 700 - - - - Johnson Controls Unitary Products 43 718444-YTG-H-0414 DNQ Side Duct Application (Continued) Model Thermostat Speed External Static Pressure(Inch Water Gauge) (Tons) Mode Input Tap CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 1100 363 410 459 509 559 611 664 719 773 Cool High Y1 COOL-B 1050 328 375 424 474 524 576 629 684 738 Y1 COOL-C 1200 439 489 541 595 652 710 771 835 900 Y1 COOL-D 1350 576 626 680 737 798 863 932 1005 - W1 HEAT-A 670 162 194 227 258 289 320 - - - N036 W1 HEAT-B 730 177 213 248 283 318 352 - - - W1 HEAT-C 790 196 235 274 312 350 388 - - - W1 HEAT-D 850 220 261 303 344 385 426 - - - W1 HEAT-A 1050 328 375 424 474 524 - - - - N056 W1 HEAT-B 1135 388 437 488 540 594 - - - - W1 HEAT-C 1220 456 506 558 613 670 - - - - W1 HEAT-D 1300 528 578 631 687 747 - - - - W1 HEAT-A 680 164 197 230 262 294 - - - - W1 HEAT-B 735 178 215 250 286 321 - - - - W1 HEAT-C 790 196 235 274 312 350 - - - - DNQ036 D056 W1 HEAT-D 840 216 257 297 338 379 - - - - (3.0) W1+W2 HEAT-A 1050 328 375 424 474 524 - - - - Heat W1+W2 HEAT-B 1140 392 441 491 544 598 - - - - W1+W2 HEAT-C 1220 456 506 558 613 670 - - - - W1+W2 HEAT-D 1300 528 578 631 687 747 - - - - W1 HEAT-A 1200 439 489 541 595 - - - - - N072 W1 HEAT-B 1300 528 578 631 687 - - - - - W1 HEAT-C 1400 628 677 731 789 - - - - - W1 HEAT-D 1475 710 759 812 871 - - - - - W1 HEAT-A 790 196 235 274 312 - - - - - W1 HEAT-B 855 222 264 305 347 - - - - - W1 HEAT-C 920 252 296 341 385 - - - - - D072 W1 HEAT-D 975 282 328 374 421 - - - - - W1+W2 HEAT-A 1200 439 489 541 595 - - - - - W1+W2 HEAT-B 1300 528 578 631 687 - - - - - W1+W2 HEAT-C 1400 628 677 731 789 - - - - - W1+W2 HEAT-D 1480 716 764 818 877 - - - - - Y1 COOL-A 1400 466 513 561 611 663 715 770 826 882 Cool High Y1 COOL-B 1350 430 476 523 571 621 672 718 766 815 Y1 COOL-C 1500 544 596 648 702 758 815 867 921 975 Y1 COOL-D 1600 630 687 745 804 864 926 988 1052 1116 W1 HEAT-A 1200 330 373 416 461 507 554 - - - N065 W1 HEAT-B 1300 394 439 484 531 579 629 - - - W1 HEAT-C 1400 466 513 561 611 663 715 - - - W1 HEAT-D 1500 544 596 648 702 758 815 - - - W1 HEAT-A 1325 412 456 503 550 599 649 - - - DNQ042 N090 W1 HEAT-B 1400 466 513 561 611 663 715 - - - (3.5) W1 HEAT-C 1500 544 596 648 702 758 815 - - - Heat W1 HEAT-D 1600 630 687 745 804 864 926 - - - W1 HEAT-A 870 168 215 261 306 350 393 - - - W1 HEAT-B 920 188 233 278 322 366 409 - - - W1 HEAT-C 985 216 260 303 347 391 434 - - - D090 W1 HEAT-D 1050 247 290 333 376 420 464 - - - W1+W2 HEAT-A 1330 415 460 506 554 603 653 - - - W1+W2 HEAT-B 1400 466 513 561 611 663 715 - - - W1+W2 HEAT-C 1500 544 596 648 702 758 815 - - - W1+W2 HEAT-D 1600 630 687 745 804 864 926 - - - 44 Johnson Controls Unitary Products 718444-YTG-H-0414 DNQ Side Duct Application (Continued) External Static Pressure(Inch Water Gauge) Model Mode Thermostat Speed CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (Tons) Input Tap Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 1500 544 596 648 702 758 815 867 921 975 Cool High Y1 COOL-B 1400 466 513 561 611 663 715 770 826 882 Y1 COOL-C 1600 630 687 745 804 864 926 988 1052 1116 Y1 COOL-D 1700 723 787 851 916 982 1049 1116 1185 1247 W1 HEAT-A 1200 330 373 416 461 507 554 - - - N065 W1 HEAT-B 1300 394 439 484 531 579 629 - - - W1 HEAT-C 1400 466 513 561 611 663 715 - - - W1 HEAT-D 1500 544 596 648 702 758 815 - - - W1 HEAT-A 1325 412 456 503 550 599 649 - - - N090 W1 HEAT-B 1400 466 513 561 611 663 715 - - - W1 HEAT-C 1500 544 596 648 702 758 815 - - - W1 HEAT-D 1600 630 687 745 804 864 926 - - - W1 HEAT-A 870 168 215 261 306 350 393 - - - W1 HEAT-B 920 188 233 278 322 366 409 - - - W1 HEAT-C 985 216 260 303 347 391 434 - - - DNQ048 D090 W1 HEAT-D 1050 247 290 333 376 420 464 - - - (4.0) W1+W2 HEAT-A 1330' 415 460 506 554 603 653 - - - Heat W1+W2 HEAT-B 1400 466 513 561 611 663 715 - - - W1+W2 HEAT-C 1500 544 596 648 702 758 815 - - - W1+W2 HEAT-D 1600 630 687 745 804 864 926 - - - W1 HEAT-A 1450 504 553 604 656 - - - - N110 W1 HEAT-B 1500 544 596 648 702 - - - - W1 HEAT-C 1600 630 687 745 804 - - - - W1 HEAT-D 1700 723 787 851 916 - - - - W1 HEAT-A 940 196 241 285 329 - - - - - W1 HEAT-B 970 209 253 297 341 - - - - - W1 HEAT-C 1050 247 290 333 376 - - - - - D110 W1 HEAT-D 1100 273 315 358 402 - - - - - W1+W2 HEAT-A 1450 504 553 604 656 - - - - - W1+W2 HEAT-B 1500 544 596 648 702 - - - - - W1+W2 HEAT-C 1600 630 687 745 804 - - - - - W1+W2 HEAT-D 1700 723 787 851 916 - - - - - Y1 COOL-A 1550 438 480 522 609 696 736 803 866 930 Cool High Y1 COOL-B 1650 510 554 598 690 782 826 896 963 1031 Y1 COOL-C 1750 589 635 682 778 873 924 995 1066 1137 Y1 COOL-D 2000 822 875 927 1027 1128 1198 - - - W1 HEAT-A 1200 251 285 319 382 445 475 - - - N065 W1 HEAT-B 1300 295 331 367 438 509 541 - - - W1 HEAT-C 1400 346 385 423 501 579 613 - - - W1 HEAT-D 1500 405 446 487 572 656 693 - - - W1 HEAT-A 1325 307 344 381 453 526 558 - - - N090 W1 HEAT-B 1400 346 385 423 501 579 613 - - - W1 HEAT-C 1500 405 446 487 572 656 693 - - - W1 HEAT-D 1600 473 516 559 649 738 780 - - - W1 HEAT-A 870 165 191 218 246 275 307 - - - W1 HEAT-B 920 172 200 228 262 296 328 - - - W1 HEAT-C 985 185 214 243 285 326 357 - - - DNQ060 D090 W1 HEAT-D 1050 201 232 263 311 359 389 - - - (5.0) W1+W2 HEAT-A 1330 309 346 383 456 530 562 - - - Heat W1+W2 HEAT-B 1400 346 385 423 501 579 613 - - - W1+W2 HEAT-C 1500 405 446 487 572 656 693 - - - W1+W2 HEAT-D 1600 473 516 559 649 738 780 - - - W1 HEAT-A 1450 375 414 454 536 617 652 - - - N110 W1 HEAT-B 1500 405 446 487 572 656 693 - - - W1 HEAT-C 1600 473 516 559 649 738 780 - - - W1 HEAT-D 1700 548 594 639 733 827 874 - - - W1 HEAT-A 940 176 204 232 269 305 336 - - - W1 HEAT-B 985 185 214 243 285 326 357 - - - W1 HEAT-C 1035 197 227 258 305 351 381 - - - D110 W1 HEAT-D 1100 216 248 279 333 386 416 - - - W1+W2 HEAT-A 1450 375 414 454 536 617 652 - - - W1+W2 HEAT-B 1500 405 446 487 572 656 693 - - - W1+W2 HEAT-C 1600 473 516 559 649 738 780 - - - W1+W2 HEAT-D 1700 548 594 639 733 827 874 - - - Johnson Controls Unitary Products 45 WW 718444-YTG-H-0414 DNQ Bottom Duct Application Model Thermostat Speed External Static Pressure(Inch Water Gauge) (Tons) Mode Input Tap CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 800 177 204 232 261 290 320 350 382 414 -) Y1 COOL-B 600 100 122 145 169 194 221 249 279 310 Cool High Y1 COOL-C 700 134 159 184 211 238 265 293 323 352 Y1 COOL-D 900 229 258 288 319 351 385 420 457 494 ,i W1 HEAT-A 670 123 147 172 197 224 251 - - - N036 W1 HEAT-B 730 146 172 198 225 252 280 - - - W1 HEAT-C 790 173 199 227 255 284 314 - - - W1 HEAT-D 850 202 230 259 289 319 351 - - - W1 HEAT-A 940 253 281 312 344 378 - - - - y DNQ024 N056 W1 HEAT-B 975 274 303 334 368 403 - - - - (2.0) W1 HEAT-C 1000 290 319 351 385 422 - - - - Heat W1 HEAT-D 1050 324 353 386 422 461 - - - - W1 HEAT-A 670 123 147 172 197 224 - - - - W1 HEAT-B 690 130 155 180 206 233 - - - W1 HEAT-C 710 138 163 189 215 242 - - - - D056 W1 HEAT-D 750 155 181 207 235 262 - - - - W1+W2 HEAT-A 940 253 281 312 344 378 - - - - '$ W1+W2 HEAT-B 970 271 300 331 364 400 - - - - W1+W2 HEAT-C 1000 290 319 351 385 422 - - - - W1+W2 HEAT-D 1050 324 353 386 422 461 - - - - Y1 COOL-A 900 222 254 291 323 340 381 431 462 516 Y1 COOL-B 1000 271 306 360 397 433 469 508 554 571 Cool High Y1 COOL-C 1125 367 411 445 500 533 588 625 647 665 Y1 COOL-D 1250 472 522 587 628 660 686 701 720 736 W1 HEAT-A 670 121 152 180 205 228 257 - - - N036 W1 HEAT-B 730 143 180 204 225 260 286 - - - W1 HEAT-C 790 172 205 237 267 296 329 - - - W1 HEAT-D 850 195 235 263 310 324 366 - W1 HEAT-A 1050 297 341 385 427 469 - - - - DNQ030 N056 W1 HEAT-B 1135 379 417 455 496 536 - - - - (2.5) W1 HEAT-C 1220 448 493 537 586 635 - - - - Heat W1 HEAT-D 1300 514 562 610 655 700 - - - - W1 HEAT-A 680 130 161 189 214 237 - - - - W1 HEAT-B 735 150 185 212 229 269 - - - - W1 HEAT-C 790 172 205 237 267 296 - - - - D056 W1 HEAT-D 840 204 244 272 319 333 - - - - W1+W2 HEAT-A 1050 297 341 385 427 469 - - - - W1+W2 HEAT-B 1135 379 417 455 496 536 - - - - W1+W2 HEAT-C 1220 448 493 537 586 635 - - - - W1+W2 HEAT-D 1300 514 562 610 655 700 - - - - 46 Johnson Controls Unitary Products • 718444-YTG-H-0414 DNQ Bottom Duct Application (Continued) Model Thermostat Speed External Static Pressure(Inch Water Gauge) (Tons) Mode Input Tap CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 1100 363 410 459 509 559 611 664 719 773 Cool High Y1 COOL-B 1050 328 375 424 474 524 576 629 684 738 Y1 COOL-C 1200 439 489 541 595 652 710 771 835 900 Y1 COOL-D 1350 576 626 680 737 798 863 932 1005 - W1 HEAT-A 670 162 194 227 258 289 320 - - - N036 W1 HEAT-B 730 177 213 248 283 318 352 - - - W1 HEAT-C 790 196 235 274 312 350 388 - - - W1 HEAT-D 850 220 261 303 344 385 426 - - - W1 HEAT-A 1050 328 375 424 474 524 - - - - N056 W1 HEAT-B 1135 388 437 488 540 594 - - - - W1 HEAT-C 1220 456 506 558 613 670 - - - - W1 HEAT-D 1300 528 578 631 687 747 - - - - W1 HEAT-A 680 164 197 230 262 294 - - - - W1 HEAT-B 735 178 215 250 286 321 - - - - W1 HEAT-C 790 196 235 274 312 350 - - - - DNQ036 D056 W1 HEAT-D 840 216 257 297 338 379 - - - - (3.0) W1+W2 HEAT-A 1050 328 375 424 474 524 - - - - Heat W1+W2 HEAT-B 1140 392 441 491 544 598 - - - - W1+W2 HEAT-C 1220 456 506 558 613 670 - - - - W1+W2 HEAT-D 1300 528 578 631 687 747 - - - - W1 HEAT-A 1200 439 489 541 595 - - - - - N072 W1 HEAT-B 1300 528 578 631 687 - - - - - W1 HEAT-C 1400 628 677 731 789 - - - - - W1 HEAT-D 1475 710 759 812 871 - - - - - W1 HEAT-A 790 196 235 274 312 - - - - - W1 HEAT-B 855 222 264 305 347 - - - - - W1 HEAT-C 920 252 296 341 385 - - - - - D072 W1 HEAT-D 975 282 328 374 421 - - - - - W1+W2 HEAT-A 1200 439 489 541 595 - - - - - W1+W2 HEAT-B 1300 528 578 631 687 - - - - - W1+W2 HEAT-C 1400 628 677 731 789 - - - - - W1+W2 HEAT-D 1480 716 764 818 877 - - - - - Y1 COOL-A 1400 466 513 561 611 663 715 770 826 882 Cool High Y1 COOL-B 1350 430 476 523 571 621 672 718 766 815 Y1 COOL-C 1500 544 596 648 702 758 815 867 921 975 Y1 COOL-D 1600 630 687 745 804 864 926 988 1052 1116 W1 HEAT-A 1200 330 373 416 461 507 554 - - - N065 W1 HEAT-B 1300 394 439 484 531 579 629 - - - W1 HEAT-C 1400 466 513 561 611 663 715 - - - W1 HEAT-0 1500 544 596 648 702 758 815 - - - W1 HEAT-A 1325 412 456 503 550 599 649 - - - DNQ042 N090 W1 HEAT-B 1400 466 513 561 611 663 715 - - - (3.5) W1 HEAT-C 1500 544 596 648 702 758 815 - - - Heat W1 HEAT-D 1600 630 687 745 804 864 926 - - - W1 HEAT-A 870 168 215 261 306 350 393 - - - W1 HEAT-B 920 188 233 278 322 366 409 - - - W1 HEAT-C 985 216 260 303 347 391 434 - - - D090 W1 HEAT-D 1050 247 290 333 376 420 464 - - - W1+W2 HEAT-A 1330 415 460 506 554 603 653 - - - W1+W2 HEAT-B 1400 466 513 561 611 663 715 - - - W1+W2 HEAT-C 1500 544 596 648 702 758 815 - - - W1+W2 HEAT-D 1600 630 687 745 804 864 926 - - - Johnson Controls Unitary Products 47 718444-YTG-H-0414 DNQ Bottom Duct Application (Continued) Model Thermostat Speed External Static Pressure(Inch Water Gauge) (Tons) Mode Input Tap CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 1500 544 596 648 702 758 815 867 921 975 Cool High Y1 COOL-B 1400 466 513 561 611 663 715 770 826 882 Y1 COOL-C 1600 630 687 745 804 864 926 988 1052 1116 Y1 COOL-0 1700 723 787 851 916 982 1049 1116 1185 1247 W1 HEAT-A ' 1200 330 373 416 461 507 554 - - - N065 W1 HEAT-B 1300 394 439 484 531 579 629 - - - W1 HEAT-C 1400 466 513 561 611 663 715 - - - W1 HEAT-D 1500 544 596 648 702 758 815 - - - W1 HEAT-A 1325 412 456 503 550 599 649 - - - N090 W1 HEAT-B 1400 466 513 561 611 663 715 - - - W1 HEAT-C 1500 544 596 648 702 758 815 - - - W1 HEAT-D 1600 630 687 745 804 864 926 - - - W1 HEAT-A 870 168 215 261 306 350 393 - - - W1 HEAT-B 920 188 233 278 322 366 409 - - - W1 HEAT-C 985 216 260 303 347 391 434 - - - DNQ048 D090 W1 HEAT-D 1050 247 290 333 376 420 464 - - - (4.0) W1+W2 HEAT-A 1330 415 460 506 554 603 653 - - - Heat W1+W2 HEAT-B 1400 466 513 561 611 663 715 - - - W1+W2 HEAT-C 1500 544 596 648 702 758 815 - - - W1+W2 HEAT-D 1600 630 687 745 804 864 926 - - - W1 HEAT-A 1450 504 553 604 656 - - - - N110 W1 HEAT-B 1500 544 596 648 702 - - - - W1 HEAT-C 1600 630 687 745 804 - - - - W1 HEAT-D 1700 723 787 851 916 - - - - W1 HEAT-A 940 196 241 285 329 - - - - - W1 HEAT-B 970 209 253 297 341 - - - - - W1 HEAT-C 1050 247 290 333 376 - - - - - D110 W1 HEAT-D 1100 273 315 358 402 - - - - - W1+W2 HEAT-A 1450 504 553 604 656 - - - - - W1+W2 HEAT-B 1500 544 596 648 702 - - - - - W1+W2 HEAT-C 1600 630 687 745 804 - - - - - W1+W2 HEAT-D 1700 723 787 851 916 - - - - - Y1 COOL-A 1550 438 480 522 609 696 736 803 866 930 Cool High Y1 COOL-B 1650 510 554 598 690 782 826 896 963 1031 Y1 COOL-C 1750 589 635 682 778 873 924 995 1066 1137 Y1 COOL-D 2000 822 875 927 1027 1128 1198 - - - W1 HEAT-A ' 1200 251 285 319 382 445 475 - - - N065 W1 HEAT-B 1300 295 331 367 438 509 541 - - - W1 HEAT-C 1400 346 385 423 501 579 613 - - - W1 HEAT-D 1500 405 446 487 572 656 693 - - - W1 HEAT-A 1325 307 344 381 453 526 558 - - - N090 W1 HEAT-B 1400 346 385 423 501 579 613 - - - W1 HEAT-C 1500 405 446 487 572 656 693 - - - W1 HEAT-D 1600 473 516 559 649 738 780 - - - W1 HEAT-A 870 165 191 218 246 275 307 - - - W1 HEAT-B 920 172 200 228 262 296 328 - - - W1 HEAT-C 985 185 214 243 285 326 357 - - - DNQ060 D090 W1 HEAT-D 1050 201 232 263 311 359 389 - - - (5.0) W1+W2 HEAT-A 1330 309 346 383 456 530 562 - - - Heat W1+W2 HEAT-B 1400 346 385 423 501 579 613 - - - W1+W2 HEAT-C 1500 405 446 487 572 656 693 - - - W1+W2 HEAT-D 1600 473 516 559 649 738 780 - - - W1 HEAT-A 1450 375 414 454 536 617 652 - - - N110 W1 HEAT-B 1500 405 446 487 572 656 693 - - - W1 HEAT-C 1600 473 516 559 649 738 780 - - - W1 HEAT-D 1700 548 594 639 733 827 874 - - - W1 HEAT-A 940 176 204 232 269 305 336 - - - W1 HEAT-B 985 185 214 243 285 326 357 - - - W1 HEAT-C 1035 197 227 258 305 351 381 - - - D110 W1 HEAT-D 1100 216 248 279 333 386 416 - - - W1+W2 HEAT-A 1450 375 414 454 536 617 652 - - - W1+W2 HEAT-B 1500 405 446 487 572 656 693 - - - W1+W2 HEAT-C 1600 473 516 559 649 738 780 - - - W1+W2 HEAT-D 1700 548 594 639 733 827 874 - - 48 Johnson Controls Unitary Products Y 718444-YTG-H-0414 DNX Side Duct Application External Static Pressure(Inch Water Gauge) Size (Tons) Mode Thermos Input tat Speed CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Tap Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 600 100 122 145 169 194 221 249 279 310 Y1 COOL-B 450 65 81 100 122 147 176 208 243 281 Low Y1 COOL-C 530 81 100 121 145 170 197 226 258 291 Cool Y1 COOL-D 680 127 151 176 202 228 256 284 313 342 Y1+Y2 COOL-A 800 177 204 232 261 290 320 350 382 414 Y1+Y2 COOL-B 600 100 122 145 169 194 221 249 279 310 High Y1+Y2 COOL-C 700 134 159 184 211 238 265 293 323 352 Y1+Y2 COOL-D 900 229 258 288 319 351 385 420 457 494 W1 HEAT-A 670 123 147 172 197 224 251 - - - I N036 W1 HEAT-B 730 146 172 198 225 252 280 - - - W1 HEAT-C 790 173 199 227 255 284 314 - - - DNX024 W1 HEAT-D 850 202 230 259 289 319 351 - - - (2.0) W1 HEAT-A 940 253 281 312 344 378 - - - - N056 W1 HEAT-B 975 274 303 334 368 403 - - - - W1 HEAT-C 1000 290 319 351 385 422 - - - - Heat W1 HEAT-D 1050 324 353 386 422 461 - - - - W1 HEAT-A 670 123 147 172 197 224 - - - - W1 HEAT-B 690 130 155 180 206 233 W1 HEAT-C 710 138 163 189 215 242 D056 W1 HEAT-D 750 155 181 207 235 262 - - - - W1+W2 HEAT-A 940 253 281 312 344 378 - - - - ' W1+W2 HEAT-B 970 271 300 331 364 400 - - - - W1+W2 HEAT-C 1000 290 319 351 385 422 - - - - W1+W2 HEAT-D 1050 324 353 386 422 461 - - - - Y1 COOL-A 900 198 233 272 313 358 406 458 512 569 Low Y1 COOL-B 760 166 190 222 262 310 366 431 503 584 Y1 COOL-C 830 180 210 245 286 332 384 441 503 571 Cool Y1 COOL-D 970 221 260 302 344 388 434 481 530 579 Y1+Y2 COOL-A 1250 361 408 454 501 548 594 640 687 733 High Y1+Y2 COOL-B 1050 253 296 340 384 428 472 516 561 605 Y1+Y2 COOL-C 1150 302 348 394 439 484 528 571 615 657 Y1+Y2 COOL-D 1350 429 475 522 570 620 671 723 777 831 W1 HEAT-A 1200 330 377 423 469 515 560 - - - N065 W1 HEAT-B 1300 394 440 487 535 583 631 - - - W1 HEAT-C 1400 467 511 558 607 659 713 - - - DNX036 W1 HEAT-D 1500 550 590 635 686 743 804 - - - (3.0) W1 HEAT-A 1150 302 348 394 439 484 528 N090 W1 HEAT-B 1225 345 392 439 485 531 577 - - - W1 HEAT-C 1275 377 424 471 518 565 612 - - - Heat W1 HEAT-D 1350 429 475 522 570 620 671 - - - W1 HEAT-A 740 163 185 216 255 304 362 - - - W1 HEAT-B 785 170 196 230 270 317 372 - - - W1 HEAT-C 825 178 208 243 284 330 382 - - - D090 W1 HEAT-D 870 189 223 260 301 347 396 - - - W1+W2 HEAT-A 1150 302 348 394 439 484 528 - - - W1+W2 HEAT-B 1220 342 389 436 482 528 573 - - - W1+W2 HEAT-C 1280 380 427 474 521 568 616 - - - W1+W2 HEAT-D 1350 429 475 522 570 620 671 - - - Johnson Controls Unitary Products 49 1 718444-YTG-H-0414 • DNX Side Duct Application (Continued) Size Thermostat Speed External Static Pressure(Inch Water Gauge) (Tons) Mode Input Tap CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 1030 237 280 323 367 411 455 499 543 588 Low Y1 COOL-B 930 192 237 282 326 369 413 455 497 539 Y1 COOL-C 1070 257 300 343 386 430 475 520 565 611 Cool Y1 COOL-D 1130 289 332 375 419 463 509 555 602 649 Y1+Y2 COOL-A 1550 586 640 696 752 810 869 929 991 1053 Y1+Y2 COOL-B 1400 466 513 561 611 663 715 770 826 882 High Y1+Y2 COOL-C 1600 630 687 745 804 864 926 988 1052 1116 Y1+Y2 COOL-D 1700 723 787 851 916 982 1049 1116 1185 - W1 HEAT-A 1200 330 373 416 461 507 554 - - - II W1 HEAT-B 1300 394 439 484 531 579 629 N065 W1 HEAT-C 1400 466 513 561 611 663 715 W1 HEAT-D 1500 544 596 648 702 758 815 - - - W1 HEAT-A 1325 412 456 503 550 599 649 - - - N090 W1 HEAT-B 1400 466 513 561 611 663 715 - - - W1 HEAT-C 1500 544 596 648 702 758 815 - - - W1 HEAT-D 1600 630 687 745 804 864 926 - - - W1 HEAT-A 870 168 215 261 306 350 393 - - - DNX048 W1 HEAT-B 920 188 233 278 322 366 409 - - - (4.0) W1 HEAT-C 985 216 260 303 347 391 434 - - - D090 W1 HEAT-D 1050 247 290 333 376 420 464 - - - W1+W2 HEAT-A 1330 415 460 506 554 603 653 - - - Heat W1+W2 HEAT-B 1400 466 513 561 611 663 715 - - - W1+W2 HEAT-C 1500 544 596 648 702 758 815 - - - W1+W2 HEAT-D 1600 630 687 745 804 864 926 - - - W1 HEAT-A 1450 504 553 604 656 - - - - - N110 W1 HEAT-B 1500 544 596 648 702 - - - - - W1 HEAT-C 1600 630 687 745 804 - - - - - W1 HEAT-D 1700 723 787 851 916 - - - - - W1 HEAT-A 940 196 241 285 329 - - - - - W1 HEAT-B 970 209 253 297 341 - - - - - W1 HEAT-C 1050 247 290 333 376 - - - - - D110 W1 HEAT-D 1100 273 315 358 402 - - - - - W1+W2 HEAT-A 1450 504 553 604 656 - - - - - W1+W2 HEAT-B 1500 544 596 648 702 - - - - - W1+W2 HEAT-C 1600 630 687 745 804 - - - - - W1+W2 HEAT-D 1700 723 787 851 916 - - - - - 50 Johnson Controls Unitary Products A 718444-YTG-H-0414 . DNX Bottom Duct Application External Static Pressure(Inch Water Gauge) Model Mode Thermostat Speed CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (Tons) Input Tap Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 600 100 122 145 169 194 221 249 279 310 Low Y1 COOL-B 450 65 81 100 122 147 176 208 243 281 Y1 COOL-C 530 81 100 121 145 170 197 226 258 291 Cool Y1 COOL-D 680 127 151 176 202 228 256 284 313 342 Y1+Y2 COOL-A 800 177 204 232 261 290 320 350 382 414 Y1+Y2 COOL-B 600 100 122 145 169 194 221 249 279 310 High Y1+Y2 COOL-C 700 134 159 184 211 238 265 293 323 352 Y1+Y2 COOL-D 900 229 258 288 319 351 385 420 457 494 W1 HEAT-A 670 123 147 172 197 224 251 - - - N036 W1 HEAT-B 730 146 172 198 225 252 280 - - - W1 HEAT-C 790 173 199 227 255 284 314 - - - DNX024 W1 HEAT-D 850 202 230 259 289 319 351 - - - (2.0) W1 HEAT-A 940 253 281 312 344 378 - - - - N056 W1 HEAT-B 975 274 303 334 368 403 - - - - W1 HEAT-C 1000 290 319 351 385 422 - - - - Heat W1 HEAT-D 1050 324 353 386 422 461 - - - - W1 HEAT-A 670 123 147 172 197 224 - - - - W1 HEAT-B 690 130 155 180 206 233 - - - - W1 HEAT-C 710 138 163 189 215 242 - - - - D056 W1 HEAT-D 750 155 181 207 235 262 - - - - W1+W2 HEAT-A 940 253 281 312 344 378 - - - - W1+W2 HEAT-B 970 271 300 331 364 400 - - - - W1+W2 HEAT-C 1000 290 319 351 385 422 - - - - W1+W2 HEAT-D 1050 324 353 386 422 461 - - - - Y1 COOL-A 900 198 233 272 313 358 406 458 512 569 Y1 COOL-B 760 166 190 222 262 310 366 431 503 584 Low Y1 COOL-C 830 180 210 245 286 332 384 441 503 571 Cool Y1 COOL-D 970 221 260 302 344 388 434 481 530 579 Y1+Y2 COOL-A 1250 361 408 454 501 548 594 640 687 733 Y1+Y2 COOL-B 1050 253 296 340 384 428 472 516 561 605 High Y1+Y2 COOL-C 1150 302 348 394 439 484 528 571 615 657 Y1+Y2 COOL-D 1350 429 475 522 570 620 671 723 777 831 W1 HEAT-A 1200 330 377 423 469 515 560 - - - N065 W1 HEAT-B 1300 394 440 487 535 583 631 - - - W1 HEAT-C 1400 467 511 558 607 659 713 - - - DNX036 W1 HEAT-D 1500 550 590 635 686 743 804 - - - (3.0) W1 HEAT-A 1150 302 348 394 439 484 528 - - - N090 W1 HEAT-B 1225 345 392 439 485 531 577 - - - W1 HEAT-C 1275 377 424 471 518 565 612 - - - Heat W1 HEAT-0 1350 429 475 522 570 620 671 - - - W1 HEAT-A 740 163 185 216 255 304 362 - - - W1 HEAT-B 785 170 196 230 270 317 372 - - - W1 HEAT-C 825 178 208 243 284 330 382 - - - D090 W1 HEAT-D 870 189 223 260 301 347 396 - - - W1+W2 HEAT-A 1150 302 348 394 439 484 528 - - - W1+W2 HEAT-B 1220 342 389 436 482 528 573 - - - W1+W2 HEAT-C 1280 380 427 474 521 568 616 - - - W1+W2 HEAT-D 1350 429 475 522 570 620 671 - - - Johnson Controls Unitary Products 51 3 . 718444-YTG-H-0414 . DNX Bottom Duct Application (Continued) External Static Pressure(Inch Water Gauge) Model Mode Thermostat Speed CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (Tons) Input Tap Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 1030 237 280 323 367 411 455 499 543 588 Low Y1 COOL-B 930 192 237 282 326 369 413 455 497 539 Y1 COOL-C 1070 257 300 343 386 430 475 520 565 611 Cool Y1 COOL-D 1130 289 332 375 419 463 509 555 602 649 Y1+Y2 COOL-A 1550 586 640 696 752 810 869 929 991 1053 Y1+Y2 COOL-B 1400 466 513 561 611 663 715 770 826 882 High Y1+Y2 COOL-C 1600 630 687 745 804 864 926 988 1052 1116 Y1+Y2 COOL-D 1700 723 787 851 916 982 1049 1116 1185 W1 HEAT-A 1200 330 373 416 461 507 554 - - - N065 W1 HEAT-B 1300 394 439 484 531 579 629 - - - W1 HEAT-C 1400 466 513 561 611 663 715 - - - W1 HEAT-D 1500 544 596 648 702 758 815 - - - i W1 HEAT-A 1325 412 456 503 550 599 649 - - - N090 W1 HEAT-B 1400 466 513 561 611 663 715 - - - W1 HEAT-C 1500 544 596 648 702 758 815 - - - W1 HEAT-D 1600 630 687 745 804 864 926 - - - W1 HEAT-A 870 168 215 261 306 350 393 - - - DNX048 W1 HEAT-B 920 188 233 278 322 366 409 - - - (4.0) W1 HEAT-C 985 216 260 303 347 391 434 - - - D090 W1 HEAT-D 1050 247 290 333 376 420 464 - - - W1+W2 HEAT-A 1330 415 460 506 554 603 653 - - - Heat W1+W2 HEAT-B 1400 466 513 561 611 663 715 - - - W1+W2 HEAT-C 1500 544 596 648 702 758 815 - - - W1+W2 HEAT-D 1600 630 687 745 804 864 926 W1 HEAT-A 1450 504 553 604 656 - - - - - N110 W1 HEAT-B 1500 544 596 648 702 - - - - - W1 HEAT-C 1600 630 687 745 804 - - - - - W1 HEAT-D 1700 723 787 851 916 - - - - - W1 HEAT-A 940 196 241 285 329 - - - - - W1 HEAT-B 970 209 253 297 341 - - - - - W1 HEAT-C 1050 247 290 333 376 - - - - - D110 W1 HEAT-D 1100 273 315 358 402 - - - - - W1+W2 HEAT-A 1450 504 553 604 656 - - - - - W1+W2 HEAT-B 1500 544 596 648 702 - - - - - W1+W2 HEAT-C 1600 630 687 745 804 - - - - - W1+W2 HEAT-D 1700 723 787 851 916 - - - - - 52 Johnson Controls Unitary Products I ( 718444-YTG-H-0414 DNZ Gas Heat Minimum Supply Air « Supply Air(CFM) Model Heat Size Cooling Heating (Tons) Min Max Min Max DNZ024 N036 600 1000 610 1330 (2.0) D056 600 1000 860 1730 DNZ030 N036 750 1250 610 1330 (2.5) N056 750 1250 860 1730 D056 750 1250 860 1730 N036 1200 1500 610 1330 DNZ036 N056 1200 1500 940 2070 (3.0) D056 1200 1500 940 2070 N072 1200 1500 1110 2220 D072 1200 1500 1110 2220 DNZ042 N065 1050 1750 1080 2370 (3.5) N090 1050 1750 1070 1780 D090 1050 1750 1070 1780 N065 1200 2000 1080 2370 DNZ048 N090 1200 2000 1230 2290 (4.0) D090 1200 2000 1230 2290 i N110 1200 2000 1330 2220 D110 1200 2000 1330 2220 N065 1500 2100 1080 2370 DNZ060 N090 1500 2100 1230 2290 (5.0) D090 1500 2100 1230 2290 N110 1500 2100 1330 2220 D110 1500 2100 1330 2220 DNQ Gas Heat Minimum Supply Air Model Supply Air(CFM) (Tons) Heat Size Cooling Heating Min Max Min Max DN Q024 N036 450 900 610 1330 (2.0) N056 450 900 860 1730 D056 450 900 860 1730 DN Q030 N036 750 1250 610 1330 (2.5) N056 750 1250 860 1730 D056 750 1250 860 1730 N036 700 1350 610 1330 DNQ036 N056 700 1350 940 2070 (3.0) D056 700 1350 940 2070 N072 700 1350 1110 2220 D072 700 1350 1110 2220 DN Q042 N065 1050 1750 1080 2370 (3.5) N090 1050 1750 1070 1780 D090 1050 1750 1070 1780 N065 930 1700 1080 2370 DNQ048 N090 930 1700 1230 2290 (4.0) D090 930 1700 1230 2290 N110 930 1700 1330 2220 1 D110 930 1700 1330 2220 N065 1060 1800 1080 2370 DN Q060 N090 1060 1800 1230 2290 (5.0) D090 1060 1800 1230 2290 N110 1060 1800 1330 2220 D110 1060 1800 1330 2220 ' DNX Gas Heat Minimum Supply Air Model Supply Air(CFM) (Tons) Heat Size Cooling Heating Min Max Min Max DNX024 N036 450 900 610 1330 (2.0) N056 450 900 860 1730 D056 450 900 860 1730 DNX036 N065 685 1350 1080 2370 (3.0) DNX N090 685 1350 1070 1780 D090 685 1350 1070 1780 N065 930 1700 1080 2370 DNX048 N090 930 1700 1230 2290 (4.0) DNX D090 930 1700 1230 2290 N110 930 1700 1330 2220 D110 930 1700 1330 2220 Johnson Controls Unitary Products 53 718444-YTG-H-0414 DNZ/DNQ Indoor Blower Specifications DNX Indoor Blower Specifications Model Motor (Tons) HP RPM Eff. SF Frame Model Motor DNZ/DNQ 024 1/2 Variable 0.8 1.0 48 (Tons) HP RPM Eff. SF Frame (2.0) DNX024 1/2 Variable 0.8 1.0 48 DNZ/DNQ 030 (2.0) (2 5) 3/4 Variable 0.8 1.0 48 DNX036 DNZ/DNQ 036 (3.0) 1 Variable 0.8 1.0 48 (3.0) 3/4 Variable 0.8 1.0 48 DNX048 DNZ/DNQ 042 (4.0) 1 Variable 0.8 1.0 48 (3.5) 3/4 Variable 0.8 1.0 48 DNZ/DNQ 048 1 Variable 0.8 1.0 48 (4.0) DNZ/DNQ 060 1 Variable 0.8 1.0 48 (5.0) Sound Performance DNZ Outdoor Sound Power Levels Model Sound Rating Octave Band Centerline Frequency(Hz) (Tons) dB(A) 125 250 500 1000 2000 4000 8000 DNZ024 (2.0) 77 64 65.5 68 72.5 64.5 60.5 48.5 DNZ030 74 63.5 64.5 66.5 67 63 57.5 51.5 (2.5) DNZ036 74 66.5 66.5 69.5 68 63 59 49.5 (3.0) DNZ042 79 70 70.5 73.5 73 69.5 67 66 (3.5) DNZ048 79 70.5 71 73.5 73 70 66 66 (4.0) DNZ060 (5.0) 80 73 71.5 74.5 75 70.5 67 62.5 1. Rated in accordance with AHRI 270 standard. DNQ Outdoor Sound Power Levels Model Sound Rating Octave Band Centerline Frequency(Hz) (Tons) dB(A) 125 250 500 1000 2000 4000 8000 DNQ024 80 66 70.5 74 74.5 72.5 67.5 64.5 (2.0) DNQ030 74 63.5 64.5 66.5 67 63 57.5 51.5 (2.5) DNQ036 79.5 69 71.5 74 74 70.5 67 61 (3.0) DNQ042 79 70 70.5 73.5 73 69.5 67 66 (3.5) DNQ048 80 71.5 71.5 73.5 74 69.5 65 63.5 (4.0) DNQ060 81 73.5 73 76 75.5 71 66.5 61.5 (5.0) 1. Rated in accordance with AHRI 270 standard. 54 Johnson Controls Unitary Products 718444-YTG-H-0414 DNX Outdoor Sound Power Levels Model Sound Rating Octave Band Centerline Frequency(Hz) 1 (Tons) dB(A) 125 250 500 1000 2000 4000 8000 DNX024 80 66 70.5 74 74.5 72.5 67.5 64.5 (2.0) DNX036 (3.0) 80 70.5 71 74.5 74 71 67.5 64 DNX048 (4.0) 81 72.5 73 76 75.5 71 67.5 65 1. Rated in accordance with AHRI 270 standard. Johnson Controls Unitary Products 55 -718444-YTG-H-0414 Electrical Data DNZ Electrical Data OD Fan Supply Max Model Compressor Motor Blower MCAI Fusee/ (Tons) Volt Motor (Amps) Breaker3 Size LRA MCC FLA FLA Size (Amps) D 024 (2.0) 208/230-1-60 9.3 43 15 1.4 4.1 17.1 25 208/230-1-60 13.1 74 21 1.3 6.0 23.7 30 DNZ030 208/230-3-60 8.6 68 14 1.3 6.0 18.1 25 (2.5) 460-3-60 4.5 34 7 0.75 3.0 8.6 15 1 208/230-1-60 14.7 74 23 1.3 6.0 25.7 35 DNZ036 208/230-3-60 9.1 68 14 1.3 6.0 18.7 25 (3.0) 460-3-60 4.5 34 7 0.8 3.0 9.4 15 208/230-1-60 15.7 88 25 1.7 6.0 27.3 35 DNZ042 208/230-3-60 9.3 68 15 1.7 6.0 19.3 25 (3.5) 460-3-60 5.1 34 8 1.0 3.0 10.4 15 208/230-1-60 21.8 117 34 1.7 7.6 36.6 45 DNZ 00j 8 208/230-3-60 13.7 83 21 1.7 7.6 26.4 35 460-3-60 6.2 41 10 1.0 3.8 12.6 15 208/230-1-60 26.4 134 41 2.3 7.6 42.9 60 . D(5Z00)0 208/230-3-60 15.9 110 25 2.3 7.6 29.8 40 J 460-3-60 7.7 52 12 1.3 3.8 14.7 20 1. Minimum Circuit Ampacity. r) 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. DNQ Electrical Data OD Fan Supply Max Compressor Blower 1 Fuse21 F Model Volt Motor Motor MCA Breaker3 (Tons) (Amps) Size r RLA LRA MCC FLA FLA (Amps) DNQ024 208/230-1-60 8.3 43 13 1.4 4.3 16.1 20 (2.0) DNQ030 208/230-1-60 14.1 73 22 1.4 6.8 25.8 35 (2 5) 208/230-3-60 8.9 58 14 1.4 6.8 19.3 25 460-3-60 4.2 28 7 0.8 3.4 9.5 15 v 208/230-1-60 14.1 77 22 1.4 6.8 25.8 35 DNQ036 208/230-3-60 9.0 71 14 1.4 6.8 19.5 25 (3.0) 460-3-60 5.6 38 9 0.8 3.4 11.2 15 208/230-1-60 17.9 112 28 1.7 9.1 33.2 40 DNQ042 208/230-3-60 13.2 88 21 1.7 9.1 27.3 35 460-3-60 6.0 44 9 0.9 4.6 13 15 208/230-1-60 20.5 115 32 1.7 9.1 36.4 45 DNQ048 (4.0) 208/230-3-60 16.0 120 25 1.7 9.1 30.8 40 460-3-60 7.7 50 12 0.9 4.6 15.1 20 I1 DNQ060 208/230-1-60 25.0 134 39 2.8 9.1 43.2 60 f (5.0) 208/230-3-60 15.9 110 25 2.8 9.1 31.8 40 460-3-60 7.7 52 12 1.4 4.6 15.6 20 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 1 3. Fuse or HACR circuit breaker size installed at factory or field installed. i) i 1 1 56 Johnson Controls Unitary Products 718444-YTG-H-0414 DNX Electrical Data OD Fan Supply Max Compressor Blower MCA1 Fusezl Modelns Volt Motor Motor (Amps) Breaker Tons Size RLA LRA MCC FLA FLA (Amps) DNX024 208/230-1-60 10.2 52 16 1.4 4.3 18.1 25 (2.0) 208/230-1-60 16.6 82 26 0.9 9.1 30.7 40 DNX036 (3.0) 208/230-3-60 11.1 58 17 0.9 9.1 23.8 30 460-3-60 4.5 29 7 0.5 4.6 10.7 15 DNX048 208/230-1-60 21.1 96 33 1.8 9.1 36.3 45 (4.0) 208/230-3-60 13.4 88 21 1.8 9.1 26.7 35 460-3-60 6.4 41 10 0.9 4.6 13.0 15 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. Johnson Controls Unitary Products 57 al co Q I ? 61 0' ` .A N *IV • jc_ COOLING UNIT WITH GAS HEAT ELEMENTARY DIAGRAM A =.to _ o OPTIONAL CCH OPTIONAL C. '--XAND .WERR SURR USE COPPER CONDUCTORS ONLY co CONNECTION DIAGRAM GND CONTROL BO% DIP CONFIGURATION SIP CONFIGURATION e i Lv v I LUG ZfilBL.801,BL C°`t ,% CCH Mt 10C 1 (SEE nio 6,B o-�K-�, e ��BLK = 2 BV j B,BR o o AGST I(SEE NOTE 61 BLK ® BLK� • I F�1031 ©23000MM 60 �I/�� B O SONBR � _� J IO2IY F�1�' �• \ii MO- _ — — — — Citltni� LR(SEE NOTE eI r-- -L �siaK 2eiren BR ■ �(n z�--1 AOOBO —2aer0_O z, • m PR O �2� omo — •_• ( v2Iv LS A S• R•RS• s I a „ ? BK C 10002 L—_—_—_----I I 1 — I9 aH Ux INv 2 EMCB B 3 ,OVB'`� , Oa,R 226� — crop °OV`T REwr �• SC, N I I Iona O 230 t fi0 C• B JUl mBR B o I Ax v v © 1 — i I P ��� C� B a a RWT ,NPpr �I PRNERFa, °LYE« ����,,,,,, 0 /gyp :_ °PpEw.-o-.M L..—..—.--23,m--.—..—. BOBR�R 2lL "'reL WIRING /� —-—_ -— V DOLT 203 0 ALTERNATE CAPACITOR WIRING ROOM THERMOSTAT co 5 1.1 J-1 DNPR-O-,�� O. e. 0 a z0„BR ANT FAN CD Cn Iw,BK ,m,PR ,PR U q rcz sv © —-———2�- �n2 "T r-- it= B O r O—O pc.--Aws._ -—-J • �� O ALrrc °o-' v---am COOL .1 ANT t�3 Cr I L'1-11 120/BK O7 Q Iry m R r 0--• .2 ANT PS u/PR{v` I Fs I ` ORB( (LOW)U.MOSS 1 ID FN1 N Q 25 ® ILOWIMEDI 2 N t� no,-0 e rRwsFOAxERO 2nlY— (MEO) <�G 3)--�GRN--T 1 ? • e 0 I L sIs 24S,PR tB v1—�`I q m., 7). ,nLor 2R,W— (MEDMIGH) c � C O f, J1(�a[pm 1 ( J�—^BLK (HIGH) !� ' ro PREWAR � • o P s o " r • I h—MAC • • I H2B6P GAS VALVE NA 2m,BR F—I I %z Zii PR BID BLKD. TEBLU 1.ALL FIELD WIRING TO BE ATYCCAL A NATIONAL COD6IN EFFECT f OF INSTALLATION OF THIS UNIT. CONTROL BOARD SETTINGSCOMBUSTION BLOWER POSTPURGE.30 SEC O 0 NTTS WBMI F=LIPC'rcZI EIP=ER rID ENSERNCNG , • BLOWER HEAT ON DELAY.30 SEC c WN GU GxGEROUS 7 • INDOOR BLOWER COOL OFF DELAY 30 SEC R RTIOttIFANY T WIRE AS SUPPLIED WITH THE UNIT MUST BE • ® K NDOOR BLOWER HEAT OFF DELAY.FIELD SELECT O 0 REV tfRALENT CLEARLY ONUMBE Wini RE FO05 R CERTIFICATION. VOLT TEMPERA-RAE CONTROLS UNIT E °- na uNr S. ....TE K STRAIGHT LNE INDICATES SWITCH PoSITON WI �WIVALENT CLEARLY RENUMBERED FOR IOENTFlCATIOtt VERIF'V O . PROPER OPERATION AFTER SERVICING. EIOEpE RE I0E8F 0 29,8E ISEE NOTE 61 3. MOTORS.INHERENTLY PROTECTED - cA°iOSE _ _,- 'F'''H-OSIBL L L,�1-2RIBKBOIBK.BBCIBK I ,E�xo I AMTgPONTYNSED FgtMERTOR 208V OPERATION.MOVE VARE 107,PR TO m.aTs _ _ wswo _ _ c O 22B,BKBO4BK.BOiIBK ILOWI ID FAN //s�� ,_ _ 11 �2ZIIBN (LO RSmI 2 N LI AZ MNMUM CN IIIT FLIT MUM FUSf ND,OR CMCLIT BREAKER SIZE oo.o X. - d B02/BK �1Z7Nq -30 _ _ N ,OtrBK IOYBR WIMED) 3 V G .3 GRN CONTROL SORB' �iE '� '_- _ ^M'tt^ �_ _ 0 O © IMED,HIGH) A 1^" L )IN/BI! aersysrc�a. 1 TSU ITar w - - w°u0 - _ a (HIGH) 5 C )2BVBRS. vmcHovENRW7vsq USED WI HCRANKUBE o ® B 00 FAD OM"ANER`°OdAO�yO M. w M e°:o us w w ,7N " SELECTIND°DRBLOWERBPEEDTOREMMNWITHINTIETEMPERATURE CAUTION-OPEN ALL DISCONNECTS 0 1 B [AN' a'oo°a`^Na°N` „°° �RBERAN°E°N HEN^^EPAEINHE^TING^NDT°�T^INAPPR°% BEFORE SERVICING THIS UNIT J00 GRIST..IN COOLING. (n — —FIELD WIRING r� rnrw0000SNa INC zwv R WIRING AND C FACTORY WIRING AND DEICES 48766-UWD-A-0312C 7 CD sT V .. 1 o Q C 0 � ' � , M a O 0) o D N 0 0 N `i) COOLING UNIT WITH GAS HEAT ELEMENTARY DIAGRAM c c OPTIONAL CON NT OPTIONAL.CCH '— GND WER SUPPLY USE COPPER CONDUCTORS ONLY 71 74: CONNECTION DIAGRAM GND CONTROL BOX DIP CONFIGURATION SP CONFIGURATION Po208230.1E0 O x +WIPR t06RK LUG f—_��_��.... 2 Q ,BT/PR- I M, 122 13t8 55�8L (y LL1L'L�lL/�BLK � I ( HEM g I ACST I(SEE NOTE 6) I eBLN� 30V• �• 1 taoreK I I Po, 1avBK •��R I • • Q ) REM _ °°+ r------------- 29VSEC \—"—I"— tavY n� IALENpLES.). Cla M 215R 81 ER BR �. ■ I ®-,-�/BK (N�Mt B I r2iMO 205/R-�1-"r71�215/R g r Y I"—.I c I ___ I I v av aR. +wm t' PRE I®� J zmn easraL p I ifs man uMr MP1,T EMcsF 18 I L..—..—..I ri 11 i tot I� ��.qR 180SRI BK_ 8/BL I BN/BW—�—_____—1 6 croK ows n[ur �('T.O E/'�23!/Y 0 0 © I _ (—I `ttt/R /JPT Q it2/BNJ 7�roYU.F ' v"v I xY I 1O383R�_ ��Nvx 1-'oeCBWOxs ¢e I I RC2 230.1e0 ID B tBSR oW Kuv-48w •^ A. I 203/BR NRL ALTERNATE CAPACITOR WRING ROOM THERMOSTAT bON —_ _—_— r �. , -- J �,�p. 1 v O 'n ,16/BL H 1 on 281/BR y l , - rc1 _ BK Rc, ,&----_��,— HMI im/.. tDT?R wNr `/ `�`o oµ P'�Ili © ____�, i co I 0 0 How EAT Q�oTC2 ® r— rN-LJ 1.Bm 'APT—Rm- ^1 0 uoce �CERT 0 0...3 �'go-AL•9443._ 0____ I I —BLK / 4f o-_T,K o—o L�` THtrwT _ _ �,Y, I x zaeK yoo+O�w'. O O O— CD TH2 ANT PS reRtc` ( Fs i F SENSE 110/BIt IIDWI ' 10_FAN Q O ® Ilow/Mm) 2 N 1 2I W L a e T1/Y (Mm) 230V 2 G+N-� N • 2G/PR�--"IKI T 230/BL— (MEDBNGHI 5 '^A C 3 = co ©0 +uwu� QwFv O fJ11 (MGM) nH 4 BLK - I w Nv��� 0 �o !°�3y us[v xri� I�� rYEL O Mt"— CI)p\ 28tlBR \VJ I 3I rir �2BS/R GAS VALVE 20.4/BR I 2rBLU ] :; RS ] W R BN O 205/R E 9DRAF BK zM�O MO OR 3 /PR al • —OPTOWY WRING AND DEVICES TEMPERATURE caNTPOLS LC 23TAGE UnrtS TURF coxTaIXS D'N22-STAGE vrvITs �2A5/PR FACTORY WIRING AND DEVICES NOTES. I.ALL FELD WRING TO BE ACCOMPLLSHED FOLLOWING CITY.LOCAL AND/OR uMr NEE vEv EI°�_° uwT SUi c 'vEb° CONTROL BOARD SETTINGS' NATK)NAL CODES IN EFFECT AT THE OF INSTA.LUTN#+OF THS VNrt. - '- ""' y CxOMMIST10N BLOWER POSTPURGE.30 SEC SB UIlirLAW w GL RROR9/FNCTA15pISCONNBCTION WHEN SERVICING pa , - ,- - S. DOCK BLOWER HEAT ON DELAY.30 SEC - ENFPPOPEft AND DANGEROUS - -- °N - - v C �(C�CH�� MOOCH BLOWER COOL OFF DELAY.300EC O ANY OF THE WIRE.AS SUPPLIED WITH THE UNIT MUST BE - - K LI-BK INOOCR BLOWER HEAT OFF DELAY.FIELD SELECT RERMOVEDSIT MUST BE REPEALED WITH TYPE t05 DEGREE C.600 VOLT °xv STixAIGHTLNE INDICATES SWITCH POSITION. O 120 WREOREOUIVALENT CLEARLY RENUMBERED FOR IDENTIFICATION.VERIFY SU 3i2cg:(SEE NOTE 81 O 1BB PROPER OPERATOR AFTER SERVICING. - -_ gggggp �2�BKBBYBK800/BK 1 LEGEND 3.MOTORS INHERENTLY PROTECTED I. ' Nc S BKBBYBK.eBKIBK (LOW) ID_FMI &FAC _ ASe I��1 FOR MOVE PARE 10TTR TO �}-2P/BK (LOWIMED) 2 N l 10°c^'^v V TAP ON OR/A 208V OPERATOR.M 1- _ q • BG2/BK �12xRR n• QS SSE UNIT NAMEPLATEFOR Mp;MLM FUSE ARDOR CIRCUIT BREAKER SEE _ 101IBI( t00/00 (Mml „Tv G ')GRN MICR ELEC.MoTOR coxrna eo 625993.5 AR AND MINIMUM Mx - w - Hs0e15Psalw�wl•>o &REMOVEDU 1 ^/ L � R,f, - Q®© (AEOMIGN) IA., MOTOR vnrcnoov Fµ rPOS CFI ,SO USED WITH CRANKCASE °Ie as ILLS Izo ¢ 1_ I LOW PRESSURE /^+` UNT COMACTA ONAL) • (HIGH) 8 C )281IBRE7LAYtOP EATER.IOPTONALI &�ERI erg 94.0WER rEEDSATE TO REMAINATING ITHN THE TEMPERATURE Rs Pv °v s sruBE Rs >v 'sx ,° 01PAN OUTDOOR FAN MOTOR ON IN vs vvessune macs [700 fiat START G OBTB°�,FANRUSU,P,CYCR RAW pDPTDNA SCTRR,GRP.�MAY E005EE„DO NOT USE�HTGGEHERI. �CAUTION6-OPEN ALL DISCONNECTS J �� RS ROLLOUT WATCH BEFORE SERVICING THIS UNIT B IBA.«x99, CO 851727-UWD-A-0312 A A 0 I O tD 1 - i 3 - .....m...-K.6.66LK,.... • • CO -1 0 -O. 1 CI 41. CO - 411. 0 1 -< Z ' -I N 0 Co 1 . ta 2 C. 1 COOLING UNIT WITH GAS HEAT ELEMENTARY DIAGRAM 6. 4c) 1 -P• POWER SUPPLY 01 i ...1 COPPER CONDUCTORS ONLY OPTICNAL CCH ...TONAL CCH .-6, 10TPR 40 1 4DS DiA CONFIGURATION GP CONFIGURATION CONNECTION DIAGRAM ,.0 CONTROL BOX I CCH_ CCN Z":4.TLI I M!- 101PR 1 TISK LUG 0 I Ten "Igi 2 1, „ ,v,,,,, _AEI. 0 0=tntzrzt 4C. I LSEE NOTE SI ii)-0411:0:0--BLK 00 LK 0 LK 0 2,sE., 10\1 05.BL 1211IL e 411+1 r 0 = 0- °---5-CD*R' OR 12SLY e Z g a a leR LIEENOTE_IL. I I 212/R e•T. K ire --r„: OCINO , , , LALK1480-<>5.440-20. -1::'')-il:::/--.----I C MR I 0 1 = 1 2 • •• ,... '.. -,,,,, I PRA I L SAL:-....,,,,,„ CB ........ 228. C)--"' -0-, °°C(4-.444' 2.28. PL.04 Li LI kli 801. L._ - - 0 0 0 - Inme 1-°OrZ:r -ewno = . cn .1 A------- oy = .® e,,0 ROOM TRERMOSTAT C.CI . I 4; Ft Ft IF1 ,-, A R 1-i _ •„_0_,_ TCL ,Iee -125N COC.7.73. SDI SDK RC2 , a, -nese ANT FAN Tir$141 _,,,,, -r cn 203. 0 0.-LIN 0-0H.,_.,I ._ . ....LIVLBL i ‘...K., • D... .,.... 11...°' ATI191 A Eg co , ••.0c C:=V7i. HEAT AUT° if ki= o .o'12 - 0-0 0-- Tri1 ANT A er L---1- ) 1 D.SIN COOL 0.-BitALAA- 1 CA IG ps. iLANT AcisT .. LILLE-4'4 0 0 0- au.,, .C,-...._ I LL I ILOW1 G_FAN • • , . CD TOW-0 44ArToimLi 0 ' TTTLT - MEM 4 O ,3_._,. 1 e 0 0 0 _ 0._„o = IMEDITIONI 4 IN) Go , i e ' -j- .1 -.. 03 ; I 0 0-BLK . L.... ! . , _., SST-CH.0w Ki CLA) I---- D 28143R 1 e ',Sal • C...2 II EEL CI OAS VALVE GM VAL. BK I 35.0 T-0- I 05/li -.-0-AI RP . L ,MPLR .-.0-C 1.ALL FELD WM,.TO BE ACCOMPLISHED FOLLOW.CRY.LOCAL ANDOR I EE45/PR KU-LiGIVIALV CONTROL BOA.SET/U.5: 0 LUTON./CODES Pi EFFECT AT TIME OP INSTALL/ILAN OF IRIS UNIT COMETSTION SLOWER ROSTPURGE 30 SEC .LI. INDOOR SLOWER HEAT ON DELAY:30 SEC g Z.CAUTION:LABEL ALL WIRES AMOR TO DISCONNECTON WIEN SERVICING L WDOOR SLOW.COOL OFF DELAY:30 SEC COMROLS WIRING ERRORS OM CAUSE IMERCATER AND DANGEROUS = L INDOOR BLOW.HEAT OFF DELAY:FIELD SELECT OPERLIONIE ANY OF TIE PARE.PS SURPUEDWITI TILE UNIT MUST BE I STRAIGHT L WE INDICATES SWITCH PC.T. 0 20 REMOVED.IT MUST BE REPLACED WIGI TYRE/05 DEGREE O MO mar (i20 , CM 7 e, ea r%TUN SLEW!SLEZ.:PESSZESSED FOR IDEPTIFICATION.VERICI IDVims.T.SECOSTDEOLS D.'..': ''''..: 7DSZT Tt''''''6:D'ST -.... '....... D.'D.D -.="!:'-'1•1'.;:,," .,:' . • ,CELIS 3.MOTORS INHERENTLY PROTECIED ••••a) - 901,Mm SSW SNIT. ' V-L1-278'.171.03ISKTOPSK 941 9411.SISOMS CVO,MIES ADMSOSAL, CS CIRCA?.SM,ASES AP 7,0,.7.71 7 E4,ZA IX IL 71 I i 208V OPERATOR MOVE TiRE LOTRIS TO ..4 6,1 •p .2 - - '4.4.4 ALs -KL '3 - - 0 M ' Cpm. I I EF2BASK.80,301,804/BIL MISR SOW) ' PIL_FAX COS, SCSIMM,SSOM)2'.1' DM DV,SODOM 47LUZ,Nuttp,Lcti,Er=NZ gillii FLI.MLYON CIRCUIT BREAKER S. .3,1:: ,,L Go 6 -E 4 AM L' ' '" -1 CO I 802. ,..B DIDC.SIDICSI COSIDIOS SOMA] MS 270 .2 .- - M2 200 2 - -. 'D.t. . .10 S •DD S :Z.: LS 'SO :3 A , 3 cri 4 I21/BK 121131- ... ' ' .3''''' ciu CROpiu AEMOVED. I 0 !; IMEITI.H1 4 7 ,4 ' .)'24.K L4L.' =7:,,...,,,,,,c 'Z' ,. '. '' - - •,t1-"'e -, - ,= - Ls Lima won-r, TS TV 3 - - i . ,S'E.EL7G:TAIIN.TDOE.41,EILHOWEN.RESLEETDETZ,REMATNIII.PAZI,N01110.EJEAXPERAToll,pE 0 A t;' ,...., 5 = )Nrrna . LOOS 041 ME.S.mSOWAs °sit CSSAMDI'''''CrES:SID:7771•7.17:::011.1,SYDSC!FOS '17 L. '‘. D D. LD SI= D. .. . •. S , 0 I AL,, = r' /,'• D. : IC CAUTION-OPEN ALL DISCONNECTS ... MOSSO,SWITCH 400 CFMTON IN COOLING BEFORE SERVICING THIS UNIT 0 , r,„s,,,,,,_„.,,,,,, co i - -- -FIELD WIPING --•-••-OPTONAL WIRWG AND DEVICES FACTORY WRING AND DEVICES 851400-UWD-C-0312 C i 7 •i' : • al i • i . 71 1 i -•, 0 0_ 1 c 0 , i co 1. i CI 7 a 7E a� I o i z 7 N 0 o w CAI COOLING UNIT WITH GAS HEAT ELEMENTARY DIAGRAM c 7 - G1,1TT 1eVISE COPPER CONDUCTORS ONLYCD $ CONNECTION DIAGRAM GND CONTROL BOX 2 LUG /W,��v ���� OPTIONAL CCH OPTIONAL CCH ,0)/PR Im/526 _ tO_ 2 I 70=2m/S a.,,BL DCCHONFIGURATgN SmCCH NFIGUMTION , NO Im/SIS Mt_ 11 (`� /�A�T IISEE NO1E el BLK-0 �{Tm}(}-BLII-0 iBK ,21/BK O 3 •: ' I e�/BL �J BmIBR BLN Q T - ® _ OMPR 0B 1 7 Q { II - r�-2mrtt _ _ _ _ _—_ - 2 S VA SEC 1 ,OS/BL Sr�.J co 1 C ,2.: ENOiESI r— _'� �l+fL MAR .n-. z'65om ze,/en o—�em/elKc 21. .. 'l`• 2 bln- - CA I Iry l I 9®O 2AM0 "' a s 2m al6 R(Q B 7 1 ,m. 10.A 1 �202/v _ _ ��� M IIr C 1 2261134 20 —,LAmR 'bK0 O 3b I - 2229; Il EMCB tmIPR - C U. 1�1 It'll n $q$p sTsv BB,(BL I ewiew I -L-1 rrwH TINT mvuT .mvi _ �a ,za;BK ..' m m e paK — — — — � — — — ro DAf . (}' III N i p'��0�ll PR .R p —_—-—_— �' TT CD I �y-------Y/' it. �-- P� zmreR T2 Q 4 An 7 i SOT/BL I I ,TIIPR -�.P. �� —-—=262"=, YI rvswT I PRP CO 23/BL ,05,8E t38,8K3„PR ,3tmR TB, w 70 TC2 ��'01 CD 11 O �O O oeBe O` EAT°� ANY ® — B K G� I I= _RNwAUTC o TX,o-�'�- d—-—- „a/BK �— nit ANT t ®v.` I ,,,, y O IH'ir�--dK l o-NMWL = 1 p o— 7 TMz .AmR{3 Es I ^mN 2 ® ILDWI ID FAN € "� e - CU 0 1 q® r rRwswANePO 1�1� 2nn—iILDWnIEDI 2 N � A i V L 24.134 -K, 'i 'B ... 2]BNJ (NEON a LTV G J R _ O i t2 O �(�REO \ ' (MED/lxGX) 0 /-�J L ® ,..,,,",,,,2 ®zsw G ,�" ,�BLK 5 (ROW }1 o i �Z NvY \ R�- a.o C^_ USED xoT I�� 2B,/BR C O i 1�1-2'f6/RR j�GAS VALVE GAS VALVE 20t/BR\0 I z t O 1 E III-2"R I RE• 2m/BR {c l 2 BL ii . 2278/0 NOTES:RfLD WIRING TO BE ACCOMPLISHED FOLLOWING CITY LOCAL AN3/CRBLU CONTROL BOND SETTIGS: p NATIONAL CODES IN EFFECT AT TIME OF INSTALLATION Of THIS UNrt. CCOMBUSTOR BLOWER POSTPURGE'.3U SEC m INDOOR BLOWER HEAT ON DELAY'mSEC O AUUTIO S I3fL ALL WRES PRIOR TO DISCONNECTION WNfN SERVICMG INDOOR BLOWER COOL OFF DELAY'.30 SEC p m RING ERPORS CON GUSE IMPROPER ANp OANGEPOUS INDOOR BLOWER HEAT OFF DELAY FIELD SELECT ERTpNIF ANV OF TIE WRE.AS SUPPUEO WRH THE UNT MUST BE• TRNGXT LINE NDICATES SWITCX POSITION O ,ID RfMOVEO,R MUST BE RE0.ACED WITH TYPE Nos OEGRfEC.em VOLTp ,m E OREOUIVOLENT CLEARLY RENUMBERED FOR OENTIRCATION.VERIFY EGEND PROPER OPERATION AFTER SERVICNG. uNT vli o K °EGr uNO SRR oRvicRN _ oEd_F NRP OP*�arva 3. TORS NNEREMLY RtOTECTEO 3 2.1 Z4FD.,f6,,TOSTSVTAFPofNyr,.SFOP ETT23V TAP ON TRANSFORMER T2 oxame MR.ao//�� RM 5�5EE uNIT NAMfP,ATE FOR MAxIMUM FUSE ATO/OR CRCOT RREAKfR sliEN )tnmR R�DPro«.LI ND MwMLw cxcwT AMPACIiv. °"OJ8 N' �- ._ • CONTROL ROARD - - - -G ,)GRN xsM su3roiB.�rv.I�.tmvsiG�szzi REMOVED DY -- _ vs _ _Loss svnicip C .),35IBK Rci RCS COMPRESS. WT.S"n"'A+sn«Aury cnnxnov REMOVED 4 As _ 511.6 7 so • • - (XIGXI 5 )2M,BR �P EC RANGE ON THE NAMEPLATE NHEAT GAG TO OBTAIN APPROX. [ vs .o TVFP Rs Aso to m CFI..N COOLING. 9 �UFTDOO" TRANSPOSE.. E. _ — -OIPTION.ELD WIRING CAUTION-OPEN ALL DISCONNECTS I1 2fiN AN FACTORYORAL WIR,NG AND DEVICES WIRING AND DEVICES To NBEFORE SERVICING THIS UNIT 3 CO { 848982-UWD-A-0312 A A i I 0 CA 1 I _, , - - • 0) —4 -.4• NJ ...< 'CI , CO —. 0 zu -A— CI Z I —I 0 i G) 0 i i f` 0 COOLING UNIT WITH GAS HEAT dNIT .90 R 3119933. zoarzao-I-so ELEMENTARY DIAGRAM a 3 6. CONDUCTORS I CO MI I 66,, CONAN I ALS AUMILART UNIT SNATCH TEMPERATURE CONTROLS ONG o IIGIIBN.= 00. 0 uNrr 0E,‘E OPER0AIINNC LE 5IIIERATURE,1,00E,7 ....I ISO MkAIIIIIIS ,,,,,,, MI I DM DRAFT MOTOR aza-me = i Ilk\ GPO GROUND MP NIGH PRESSURE SWITION OPENS 0,626 PS. 3 TUBE ,: 150 '2 O CO FII CIO, I I▪ "''L. 22BAIN = I ec .R N 40.F.:r 5 616 I. DEAN INDOOR FA N.TOR NCB INDOOR MOTOR CONTROL B.. L,3 Low AN6ssuN6 swg,op6,,.,,pA,G LS LIMP SWITCR 02,1-S. . '55 6 '25 9 ALS RS I TUBE 66 OM 27.0 , I, 6 120 9 C 0 ...• MI CONTACTOR COMER AND 00 FAN ALS I. 201All 'ai. SNAIL C .RE I ODFAN OUTDOOR,ri MOTOR PS PRESSURE SVATCN 3 TUBE 7 o42.11 ' 190 .6 120 9 * El MASK 7 • • RC I COMPRESSOR RUN CAPACITOR ALS 'P' 1' N - .1170: RS i RC2 OUTDOOR FAN RUN CAPACITOR = HP i 0 .1 T UBE 15./32 IPFP• % 71' '715°9„'SFUORT'17E7 I'OV„6/ WOW 5S ... Cn . Ei . . , ...E FTCR START A.IST 5 TUBE as = cue- LP P9 S4 SA kice 0 Cn S3 ''' . .••. -••-.OPIIONAL MMHG AND DEVICES 11) .., : P I-5 MII 3)PHCOOLNIL ( • 0 NOWISE 22.26 OPTIONAL rol SW CONFIGURATION FACTORY WIRING AND DEVICES (.0 tD OFP13 0 = • • CD • • 0 ''''CC'C'' ''''BET"'N,......, '/T116 IFF:Itrl=TCC191:::11CICEFCrEC='T ITTLII7rSTX.I.ELL'ACQAONL a) • • 2) Hm2 C.F.LFVF.Sas.33/ OOF T HIG OPT 0.1/ • A 1.. .... 1... C NCO 0.1"40,& 27;=.7,..MITTEGZtr,74°,,TrZt.".1,"Ei. 0 — I ,3 ,0_,...„,,,T,„ —,3 ... .,,,,„_. 600 VOLT WIRE OR EQUIVALENT CLEW,RENPABERED FOR CERTIFICATION CO Ao, 4 - ...,..-.^.', VERIFY PROPER OPERATION AFTER SERVICING HAN.. POP. ,w,, . /0,..N II II = TIAIX= ,. 3 MOTORS CIE INHERENTLY PROTECTED ' f....1 I -,,J 4)--..-^'," (, A 4331=OVIOTITEV:LTOVIT''''''''"'"LT''''''"'" , 0 —3 , - 3 DELAY I 7 NMI 7) A0.11,1,9 E '''' ''' OF1';'L A"GRAF.° , THUNT CONTACT ALSO USED mnrri CRANKCASE NEATER 110FAIONAL I i A 1,...„ , .,,, -,6 fte 6 SEE UNIT NAMEPLATE FOR.XIMUM FUSE ANDOR CPC.BREMER SCE i C J .,!'. PHD Me..CIRCUIT AMPACITY 0 . 4'3 4111 H= 0 FOR NEAT I O. . “ I I 4k CONTROL BOW.SETTINGS 0 ,,,, -I')-'"7 t: H3 15.. -. COM BUSTION BLONERPOSTPURGE 30 SEC CDOOR BLOC.BEAT.DELAY CO SEC g ao INDOOR BLOWER COOL OFF DELAY GO SEC - INDOOR BLOWER HEAT OFF DELAY MELD SELECT f STRAIGHT LINE INDICATES SWITCH POSITION 0 120 0 . = "PR •E r i... F 1., RED...ACV Rm• BLK H.,.UM SELECTOR BOARD SETTINGS .N604.1,1 S'A'" 7,0,_ 0 COOLING W ARI RATED CFM = El C SEE TECH L RATURE N 2.1 = ' 0 FOR A 1301111gAL FIFORMATION f.D : T'''SP .' I 00, 0,00., HEATING A•NOMINAL HEAGNG CFM Z I C SEE TECH L.ZAERATURE 0•FOR ADD. W WFORIACIION '''S.S. '-.......1 -')1_,: 0 1 6111 A 3 601606,COOLING CFI/ LK E __0_50_ r_o_50__ 0 : ..NOMINAL C00.6 CPA X 110, C•NOMINAL.0.6 CPA X 90, S"T'1".' 1 /I . 9 = 1 0 NIA OW. : CAUTION-OPEN ALL DISCONNECTS DELAV A 3 31630,06019 i—i BEFORE SERVICING THIS UNIT 0 I B•MAIM CONNIE 0 3 0116'CLIMATE ''' 6)-7 I 0 3 0 l'EMPERATE COMM, r—r4c 8550713-UWD-A-0512 c 1 201.R = : ••=f: 1 CU 1 1 -0 0 0_ C 1 0 0. cn —I 0 i .<4 ! • 3 ': —. (.3 :! 0 0 :• CO ; 1=1 ! o !: Z 3 ! C) 0 !: • c=, IV CA C .! COOLING UNIT WITH GAS HEAT tOIND POWER SU., 20.30-1. ELEMENTARY DIAGRAM ct = ! U.COPPER CONDUCTORS • ' 415 CD =! CrOMPR TEMPERATURE CONTROLS TNC.VSTAGE UNITS ' I 0 S' ' ��© 1_ 0,.. 004. ',Da< , ,.„ 1 '''''''s-7—'''''ci';'2' ..-' 0 1 = 1 0 or, • 41 I0\ 3 1 0. 1 I ' ,,,!= C i css.ss sco,Alls ,, oiolm LI OCEAN 0 /: r. / CORO CO !. = I s, <!, !, -- - 3 i 0 1 104/R . 9I1V-se X N I FL ' 7511: , 33L/BE .. .,. I= NM 32765 et I.0 : LEGEND 711 :ALS AUXILARV OMIT SWITCH 1 --, L..--67,0--•-i CFM. CFNI SEL ROTOR BOARO ..1.1 : 1 M • 513 COM. COMPRESSOR DM DRAFT MOTOR * - CD —, -9 I'IRRII• PACS ELEC BLOWER MOTOR CTRL.BOARD I I=1 fv3 nom'e)—cm OUTS.BN ;4I a. soca ,9 ,1 GNI, GROUND 011. HiGH PRESSURE SWITCH oPENG o 525 P5iG 0) e OFAN /NOOOR FAN MOTOR 0 1:::I „...1)—HEATO9 ( .11 PIO 11 NCB INCOOR MOTOR CONTROL BOARD CIO I 1" 1 ss " s,c sz!, , „,,„„,„s„,„0,,./••.s, CD LS 'LIMIT SWITCH MI CONTACTOR.COMPR ANO 00 PAN 0 :. :. I I ' I 5)—C151115 (' R 0 90CHR ODFAN OUTDOOR FAH MOTOR RC1 COMPRESSOR RUN CAPACITOR CA OFAN R. OUTDOOR FAN ROI CAPACITOR = . COOL 6)—E1N RS ROLLOUT SWITCH I" A ; OPTIC:NAL G. T1 TRANSFORMER 24V 230V 01.1 "e . C I I "r2 I ID-'111 (, ,, ,. ., FOCR START ASSIST •, D_. S/P CONFIGURATION , A I 14 I„),„„ (• •,, „, . ' 40 CO c 24,o IR;C;FIRI.LI;NrICIN 1 ALL FIELD WIRING TO BE A.OMPLISNED FOLLOWING OTY.LOC.I I 13 1,)-.1.1.111.2 1 e .3 ,, DLL. ,;;Io„.„•1, 0 MOOR HATIO.L CODES IN EFFECT AT THE TYE OF SISTALLAGON .THIS UNIT. Co3 i I A ' 15 15)—ORR 6 .19 5-1°-135 .--Q ::: Ealsr"..::= ..„. L.. ,..,,,..0 1.CAUTION:LABEL ALL WIRES PRIOR TO viscorixecnox voisN SERVICNG CD ; ! c I 4 NMI 1)—DELAVili E, 4..4 CONTROLS.W..ERRORS CAN CAUSE IMPROPER ASO OANG.OUS ma• : .ERATION.IF ANY OF THE WIRING.AS SUPPLIED W.THE UNIT, --°—2° 'ICI6).& rr"11=01°E=ErrrATZT:4174=MENE4icAnoN. Cr) ,. ADELAV I 7 NMI 7)--ALGUSTGR ( ''''' 01.75.1ZAv .85 MEM,PR..aPERA-Dos AFTER.RVICING. .• 01. e • sa.Ecr ,3,MOTORS ARE INHERENT,PROTECTED. : I' D—. • --- Es • 1 1)-331. HINGSW1 '41).. rIf MI 41AIRT17101=TTEVISIINAT1IT17"AT1°15:'II'"15°5T:I'11''''.11 0 . .— II REMOVE ''' •0-225. ., ,HUNT CONTACT Al.U.D WITH GRANIFC.E HEATER•OPRONALI 1 FOR HEAT I -r 6.SEE UNIT NAMEPLATE F.M.IMUM FUSE ANCFOR CIRCUIT BREAKER SZE * : • PUMP 4 ,,),,,,, e• AND MINIMUM CIRCUIT.PACITV I : • ' • • 6.III 6)-235/W Ct- „ I--- — —FIELD WIRING 0 —••—••—OPTION.V.I.AND DEVICES ' Cf3 Fr41-11—F—i— • e FACTORY W/RING AND DEVICES LIA^ 0 ' ,• 0,-„,„ -e551 — — 11- —: f— 251711."1II->•5. ;1 CONTROL BOARD SETTINGS: 0 „ am, - I FORE O. H } 1.„. INDOOR...HEAT ON DELA,30 SEC INDOOR BLOWER COOL OFF DE..30 SEC g BO I 0 C.SELECTOR BOA/.SETTR.5 '5 :NIP. "("-- 3,- INDOOR BLOWER HEAT OFF OELAV:GELD SELECT 0 129 ,'COOLING:A-MIRATED CFM STRAIGHT LINE INDICATES WATCH POSIGON i'55• 215AR .I II.TING.A..NOMINAL H.TING CFM FRNIN .(1"--1 I 7)1,, 3., : 1 r0:1 TgO15114=11FIIIIRMA SON .zosort "RC1-15L 1)1: A,LS e • I ADJ: A•NOWA.COOLING GRA B•140141.L COOLING MI X 1105 ,.r.5'; :35:9F5'11 r - , C-NOW.COOLING CFA.X 9. (15 CAUTION-OPEN ALL DISCONNECTS :• , El-NUISID CLIMATE ,,r-- BEFORE SERVICING THIS UNIT --.1 c•DRY CLIWie I 0.TEMPERATE CLIMATE •' 858752-11WD-A-0512 i 301'BR I I ' RON : vOII 1 H G) ' 1 C I : v4II CIF) I : ..1 CO I ; 43. • 0) A r y n A d A 0 3 -I 0 1 0 0 2 0 0 COOLING UNIT WITH GAS HEAT c� 20812301.60 P0���SUPPLY "° LNYDPP�3 ELEMENTARY DIAGRAM c 1 A COMPR - MI LEGEND • TEMPERATURE CONTROLS-ONO O ALS AUX.. MIT SWITCH Q 101/BK �i 11�1a KJ RC1MIME CFM SELECTOR SOPAD UNITSI2E DEVICE OPERATING TEMPERANRE(DECBF 3 © 1IXf/BB Ay COMP COMPRESSOR OPE - OSE 02 BUJ , Q t@/v v' I ®M I DM EM[8R DRAFT SLCY.ERMOTOR CTfd.BOARD OR RS 30fi0ELs p ;E OMCB BLK HPD MG HUPRS�SURE SWITCH OPENS@S PSIG ;60 - I FMCS A B�_ rCk OR MOTOR CONTROL SOPRD O Z)0 Ls LP©®� ODFAN P13 I/�� 3 OROS OUTDOOR MOTOR CONTROL BOARD yi 22I/BK PRESSURE SWITCH COMPRESSOR RUN CAPACITOR I HP ® ® 0.0lLOVT BwITtltT1 TRANSFOIMER.20V.230V ''ww L 229/BL1-6RRI}-cm.OOTMTAK C ',RAGS m I�t1.1r MMTM3K E'. .1 -..—..�A`OIIX RING AND DEVICES /\5. s)-com N. �G s� 2.,.., RING rWD DEVICES Y�d i 3 1 3}C2AR t �Tf 4� 2a0v/PR OPPONKCCH N CD ElII-+ 0-CUB. CI .1 3.3 222R CCM SP(CO OIRAIKION COO . 16 I rYtrY C6 WANy"'lQ L. -L.K ry ME3 .19 T I 11 I1 -AIR (2.512 ® O/P��PCCC��-H��_F...I��MG---U....00 ALL FIE)WIRNG TO BE ACCOMPLISHED FOLLOWING orV.LOCAL N 2 0 2� CC�J---�KQ t OF TXS UNTTOIgL CODES IN EFFECT AT THE THE OF IN3TAW110N Cl °HUT I 2. N:LABERL ALL WIRES PRIOR TO DISCOXTRCTION NHEN SERVICING CO 9 I I. I1}V2/O �< 236/O ��K_� GONTROlS. PAGERRORSCANCAUSEIMP�PERANpDANGEROOS N < q OPERATION IF ANY OF THE WRING.AS SUPPLIED WITH THE UNIT. (a 13�BLU.WHT/W2 3 FJ4.0.6, MUST BE REMOVED IT MUST BE REPLACED WITH TYPE 1050EGREEC. Q Imo( 800 vOIT WRE Oft EW IVALENT CLEARLv RENUMBERED FOR IDENRFlCARON. • 1$ I age-GF t5 \9 xgHUMiixwT EM®�-5o EPoFV PR°PEA OPERATION AFTER SERVICING PDJ -6M TORS ARE INHERENTLY PROTECTED. < 1}DE sewers _< • — B ow'�AEur OI R IRED FOR 30 VO TOPERAT ON FO 200 OLT.MOVE10]FR CO ° IuvMc F. o TTS T0208V0.T1ERMINPL ON Tt. Q DELAY ]�I)r ODJUSTP .] B oRAAr4-n ,&SHUNT CONTACT ALSO USED WITH CRANKCASE HEATER(CPT1ONL( CH x=1 6 (�CFM OOT/Y-BK �'6 ®x —• SELECT 6.SEE UNIT NAMEPLATE FOR M FUSE AND/OR ORCUIT BREAKER 512E 0 0 r-- D MINIMUM CIRCUIT AMPACITV. 1rP6 221/BR r'TAY/Wt a M CED REMOVE Ie2 2)-225IPIi �, , OR HEAT PUMP - I A }23. 0 a I xuT}— 10)/P.— NTR4p MDSETTNGS'P MG p B0 e-I}226M' �A DOOR BLOWER HEAT OF DELAYFDEELA E 30 S 30 EC o v L 230V 0'®RI INDOOR BLOWER COOL OFF DELAY 30 sEc b BO }233?i QINDCOR BLOWER HEAT OFF DELAY--FIELD SELECT S . I ( 0 STRAIGHT LINE INDICATES SWRCH POSITION O iro [--0-g..a .1 I-1 Ca F 5E 2MM11]r 1�> 1 ALT 0 _ COO LING:AORBRATED TANGS 0u99O ---n . Q COOT A-PRO TEL CFM Txw sF ._r : • C- H rc -SEE TEC LITERATURE RI/ LOT R 2O5R :::7 D-F ADD ORAL INFORMATION 2a5/PR(c`�11 )OHEATS G.A.NOgINOL HEATING CFMI ,, cr- i�K= C_ `g_C TECX LITERATURE _I'-ly'7 JrWe (0_ FOR PDDIRONAL NFORMATK)N 205/RAL 0 A-NOMINAL COOLING CFM ns E r `� v `� av • o:w"""COOLING CFM"'"°" <- I I1 ') CAUTION-OPEN ALL DISCONNECTS • DELAY A-STANDARD B BEFORE SERVICING THIS UNIT O B•HUMID CLIMATE D-TDRY EMPEMAT OJMAIE I tc I -2� I 857169-UWD-A-0512 • C 01 iBR • E • T� V • ...0 0 ,x Q _2 Cl a • c_ —4 . . ..< g_. c, 0 OD . 7 — 0 . 0 Z • 7 0 • CD CD cn C COOLING UNIT WITH GAS HEAT „...1......2,X0 pOwER SUPELE 20.30/ASO ELEMENTARY DIAGRAM 0 ,' = USE COpPER 0 = I CONDUCTORS , 0 .• :• = :•• "...‘ Z 0 irojle /GI En C 0 102rr 0 1 0 I ESZ\ rEL =CL :i i i °PEED -n = • * :•• (7) 1 COED ".?•: U xavaL .e2ESK = ) /SLei Y,I4, 1 M LEGEND &CI) La -- - 22SAL p, 1 . . PECS CFMCB CPA,'s ELEcToR BoARD CD . {=1 1--,-1 0.-CFH OUVWT.Bn 6 _. COLA PR COmPRESSoR . . , GI .• Om ORA,MOTOR . • El. D,„.,,,.., ( ...' Sul i EPEES ELEC BLOWER MOTOR CTRL Bona° .I' I -,_,, SS '''' ONO GRouND M. 5M, 5.2-.200LEIL HP LPGR PRESSURE S.,.OPE.4 035 5/SIG °FAX INDooR FAN moToR X . El •I ' I 3)-C2. L'"P'C' :I':c'PR'E'S'S.Tu'R'E's.w7T7 p'op'ETN's7,7 PSI° CD :•• El.-71,1—• D—.1** ,,,,,,, Ls Limn.SWITCH ELL cONTACTOR.COMER AND oo FAN . IN MIA , 1 6 I b)--r1pr ....° 4., . ,,,,, OCEAN oUTDOOR FAN MOTOR KJ 0 ORTIONAL COL °MOB oulDOOR mOTOR CONTROL_FIGARO . CD CO ..... IRC, ComPREssoR RUN CAPACITOR .,...AT 2.• 2) 2 ...2 — VP CONFIGUMTION „s ,...,,sw..., NJ CD :•. 2.0 ---ji"'-0 N.Te. . i• :••• • ''55'CC.I'....5'.. I ALL FIELD AIRNIG TO BE ACCOMPLI.ED FOLLOWING CIT,LOCAL : • All . ' ,9.-.°,,, 5• 15 iii,,,,,,,c,;,,,,,, 0 :INvIl../.041,1;14011/1L CODES IN EFFECT AT THE INIE OF INSTALLATION 0)c I a J 4)-01ELAWR A —., L.. ...1,i..0 2 CAUTION:LABEL ALL WIRES PRIOR TO DISCONNECTION 3.1EN SERVICXYG < . :• yo ; CONTROLS.WRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS . I.v•.I—at=4* L 0 :• •DELA, .•,—. A . B ,ti..10-CFM OUT/r-BE A.PIS er VERIFY PROPER OPERATION AFTER SERVICING : C , 0_. 3.MOTORS ARE INHERENT,PROTECTED. a Ld Erwrwl 0.0. ....- FOR I —.441,,,H1 IFY5 I Z.VININT CONTACT ALSO USED WITH GRAMICASE HEATER NIPRONALI co : „EAT pump i 4 4)-,..' e is4 --1-- ND. — :• • S LErE,112.7.=cE.R.LE.FA,D,I=MIGA FUSE AND/OR CRCUITSR..R SVE 0 . .., ir•. —•:—•=••=4'5r1f0=r1RING.AND DEVICES CO ,••• •• t 1--/')-'''' PRI , FACTORY VYMING AND DEVICES : 11 CRA SELECTOR BOARD SETTINGT ')-'3"'L COOLING,A•ARI RATED CFR 0, e- s... e _....., ;,..... ,,,,, CONTROL BOARD SETTINGS. C.BlISTION BLOWER POSTRJRGE 10 SEC INDOOR BLOWER HEAT ON DEINV 30 SEC INDOOR BLOWER COOL OFF DELA,Eo SEC NOOOR BLOWER HEAT OFF DELAV FIELD SELECT STRAIGHT LINE INDICATES SWITCH P5.110N 0 . g 00 0 120 5'5 IFF , . 0) 3 . :• • :•• =... 6--II :•• N.D.A-NORMAL REAR.CRA L4 '7 ;-1)-1-RED ADP A•NOMI.L COOLING C. B•NOMINAL COOLING C.X 1 IVA I 1--- D—rEL C-WPM.COOLING CFM X 90, CAUTION—OPEN ALL DISCONNECTS 0 Hi . :• , OELAT: A•STANDAFO BEFORE SERVICING THIS UNIT i B-HUMID CLIMATE I. C-DRY CLIMATE I I IC 5)- D•TEMPERATE CURATE 858753-UWD-A-0512 zol aR .•' i 1 ; ..<H i . ,..., ll J ll 1 0 c9) i , I • Cb • Al _, 1 - A 01 A € G Z 0p 2 A COOLING UNIT WITH GAS HEAT �D POWER SUPRV20M2%-160 ELEMENTARY DIAGRAM �'" USE COPPER CONDUCTORS ONLY CO A Cps it: I I LEGEND TEMPERATURE CONTROIS.ONO�� i fe CO• CULT BREAKEP Y LIMIT ITCH UONIi SIZE OE SSCE F© tyt/0L • CF MPEE560RR 80ARD 3�� 2 270 (J .%ry�y • DRAFT MOTOR %-039 ELEC.BLOWER MOORCTRL.BOARD MS -- �♦9- • GROUND CFMCB A IB,�,II��yy'�. ODFAN ' CO HP HIGH P E SURE SWITCH OPENS[g 625 PS I G 40%B 270RLS ' COMP I COM LO- 2%/� NP BLN DaIR !DEAN FAN MOTORALS 1Ea 30 COND IMCB INDOOR MOTOR CONTROL BOARD Z00 C • M1 L BRN O I W PRESSURE SWITCH OPENS 03 50 PSIG 3 TUgeLs '. 120 LS EMIT SWITCH .4.5 IK1 M,C 232/BL /J®Q 23t:8L• �' PRPDM OR.COMPR.AND OD FAN RS 2]O _. _ �P4 CONTACTOR, FAN MOTOR 042-OSB L4 TUBE S '75•60 t45 22!/BK LB RESSOURE SWITCH ALS 4y' HP OLLOUT FANRUN CPPACIOq RS 2T0 - /vF2-1 • ROLLOUT SWITCH 50�. LS t% • ® f L T1 TRANSFORMER.24V.230V MS 180 2 --- - • El LPP 22918E El T-I}-CFM OUTMR9N Q me CD AND DEVICES 4.8 € C� IPS SDI 5)-COOUBL -51 5S 0 -S 0 240V43N —FFACTORY WgNNG AND DEVICES d • • ( I=' /I 3 I)-C2/BR ( --3 4- 0 240`//PR WIRI CD ( 1 --1 H ,r C,/EO ( -1 3- 3}C COOL I 6 14) V"IY 0 �_ IDFAN • t2 M NOTES'. T :. t2�--Rrtt (2�2 O 1 ALL FIELD WIRING O BE ACCOMPLISHED FOLLOWING CITY LOCAL CD O • X-T I 2-I 1YWtIN� -2 OFwi110RIS UNIT CREED IN EFFECT AT THE TIME OF INSTALLATION rr 2.CAUTION.LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING g I �4 I10-v210 —(a-la23e/O ONT�gOp FNARVOFBTHEWPNGASSUINAROPER AND FPUEDWRXiXANNROUS NC C. D ]� 1 -BLU-WNThY2 (J-13 2 GOO V' MUST LT WIRE OR EWNALEN REMOV.IT MUST T CLEARLY RENUMBEREDFFOR DENWITH TYPE 1. T FCATO. 00 b ADJ I 15 15r CJPR L� — I�r+:LMi P.P. EMCO�- VERIFYROPER OPERATION AFTER SERVICING. A —ems—ts P. Bo oNi swO.I„rui ���° ,mmn N li 4 )-DEANA / E.F.TousB6uv �' 33..MOTORS ARE INHERENTLY PROTECTED. �4 /4 µACTIXtY W IgED F00.2%VOLT OPEPATION.FOR 208 VOLT.MOVEt O)PR a) 11 rt I )_I .JUST/PR _, —1N,,,P}-2.BNw,> �.o • I° wE o oe oLr ERMmLoffn °R SELECTr---w 2� Q 5-REMOVED I C I 1 J 1 CFM OUTAKBN (6-,6 e / 1 200Ri 12✓4V SEC ^do- S-AND MINIMUM NA NACIRMEPLATE FOR IMA VMUM FUSE AND/OR CIRCUIT BREAKER SEE CBI D 1.8 1 11)-221/BR n.Fo ® _2 TSIA < i ® - IPS 2 2�225/PR0 1 HEAT PUMP I 4 I 23MY A6601I R 2,5R CONTROL BOARD SETTINGS'COMBUSrON . O 60 J-I Er 226W I INDOOR BLOWER HET ON MAY' 30 ECC 90 • 'l D. QNS�0- ---0-50-26R RBIOVIERHEAT OFFDELA'FIELOSELECT O 0 S_ a v " " 120 STRA OTL NE ND FATES SMTCN WITION O 180 CO 24MPR{3 n— I cs I c sE 0 CU C- ? c,.,. . • . ,. CFM SELECTOR BOARD SETTINGS COOLING.A.ART RATED cFM • a .,...Re C-SEETEC ITERAORE 0 ' D-FOR AODtCNALI 1,..TIO 0 ! HEATING.A-NO NAL HEATING CFM 245IPR{�4f �� vt ) GAS VALVE O.FOR TEC T I IONARL INFORMATION L.E. RE•II n ' A.NOMINAL COOLING CFM BLK �N CAUTION -OPEN ALL DISCONNECTS o B.NOMINAL COOLING GPM XSOK '' N41 F:'I BEFORE SERVICING THIS UNIT • D N/A NOMINAL COOLING CFM 90% c6 i�== I) ODEIAV. A.STANDARD I �BL BLU HUMID • DOA E • - CLIMATE I PITq W D.TEMPERATE CLIMATE I 'T :. C I 2p1 855354 UD-A-0412 O i 7 1 0 aI • c , • • 0I (n IL -I • 0 1 .4( , • •7' r • = -0 ....• . . . cn .i: 0 . 0 1 co = 0 .1 0 o i, Z = . 0 ,... ,, 0 !1 01 : • • .. C 1! COOLING UNIT WITH GAS HEAT iND POWER SUPPTY 205/22.0.3.60 USE COPPER CONDUCTORS ONLY ELEMENTARY DIAGRAM o o • 74: ;• o I ....- I I :EGET., ,,,,,,„,,,„,,,,,,,,,..,,,,, = ALS ALOULARY LIMIT SWITCH CBI CURCUIT BREAKER ,„..„1,srm 0E,,,c, OPERATING TEMPERATURE ID.B. •) = . . . 13 1 i Ir.°12/ST CH I.11,0_ I 0 C..)110BIT --H--. M1 [FMCS CFM SELECTOR BOARD COMPR COMPRESSOR RS CL =3 'Or LS 'SG 5 120 9 MI c I . _I M DRAFT MOTOR FMCS ELEC BLOWER MOTOR CTRL BOARD ALS ,N O• RS YEL ONO GROUND CFMCB A IS 1 i :" COPAN, HP HIGH PRESSURE SWITCH OPENS g 625 PSIG !DEAN INDOOR FAN MOTOR NCB INDOOR MOTOR CONTROL BOARD LP LOW PRESSURE SWITCH OPENS'-g 60 PSIG a TUBE BS. ' ALS „, , ... ... ImIL*. 0 i COMP NI COM LO RS 270 CO 1 CORD a 5 TUBE 0 DM LS LIND SWrTCH ALS = MI CONTACTOR.COMPR ANO OD FAN °DEAN OUTDOOR FAN MOTOR CO OMCB COTDOOR MOTOR CCNTROT BOARD =0 PS PRESSURE SWITCH I• La RS ROLLOUT SWITCH T1. TRANSFORMER.WV.230V CD:. ID __1' r LE Cin . i1:::1 —'- -. ... 1,` •0 7,-1 ID.CFM OUTAW-. 0 CO . '• CD C —11 ----• ••1---1---FO'Al'O'N'AinlING MO DEMOS :.• P5 ,. I' I l_, . FACTORY VB..AND DEVICES •. CU :.• 1! CI' I a 1 —`'1"1' 0 —4 4—4) 2aMPIR C• . 1 . ai MEAN CD i; COOL NOTES. (2, 2 C)ii PI. Is.1 1 ALL FIELD WRONG TO BE ACCOMPLISHED FOLLOWPG GITY.LOCAL ;MICR NATIONAL CODES IN EFFECT AT ME TIME OF INSTALLATION 0 OF THIS UNIT 0 2 , ,i CO I '44101 1.)—Y2/0 a..la 222/R 2.CAUTION:LABEL ALL WIRES PRIOR TO DISCONNECTION WN..IRVICI. .....„. CONTROLS.MTN.ERRoRs cAN cAUSE IMPROPER AND DANGER.. D43 OPE.TION.IF ANY OF THEM.,AS SUPPLIED WITH THE UNIT. CA) . "".1 a'"1'111T11' 3 m.13 ...„ ,.mc..2,30:,.40. MLIST BE REMOVED IT MUST BE REM/KED.,TYPE/06 D.REEC. 600 VOLT PRE OR FOUNAL.T OL.RLY RENUMBERED FOR 1001TIRCATION. CI • A...2i. , 4 NIGNINIT war • VER,PROPER OPERATION AFTER SERVICWO.,. C.43 A .M 1 .,CT/PR 5 mm,15 ''''''R 3.1.10TORS ARE INHERENTLY PROTECTED. , . I D—OELAYR •=24V SE'C' ' CRY WPEO FOR MO VOLT OPE.T0N.FOR DM VOLT.I...VE.107/PR CD •CD : .AICE-rTO 208 VOLT TERM AL ON TI. .. ,. r.FRV •PRI ,,i, '' 5 REMOVED < . ,• : A CE11 6 6 —40— 6 SEE UMT NAMEPLATE FOR M.B.A.FUSE ARDOR CRGIAT BEI.NER SI. 0 • --(: 1,,-..7>:::'''''43-rX.17172.'143- AM MINIM.CROW....roAcrry o • — ., AMP 71:7 1•11 1)-22WEIR MtWoW1— A = E: = * — - —.I 4 • . R..,... i. 4 a)--•234, ' a __„„ ,, 1 N CONTROL BOARD SETTPGS• . CO , S.11 6)-22F. I (t—.. COMB.VON ROWER POSIPURGE 30 SEC INDOOR BLOW.HEAT ON DELAY 30 SEC CI • INDOOR BLOWER HEAT Ofr DELAY MELD SELECT STRAIGHT LINE INDICATES SWITCH POSITION 03 CO „..„„.,CFR SELECTOR EI.R0 SETTINGS 3 , • 1 COOLING.A•.1RATEOCFM ..........FR ,..../ _...,n, . • .TING: , ---r--q-• asty• •C,.m...---1 1 ALT GAS VALVE A-NOMINAL R.,.CFM i C• r TECN LITE.ILRE •0• FOR ADDITIONAL NFORMATION ...PR.,. LH...L1 s.. ), fl AD, A-NOMINAL COMING CFM 0-NOMINAL COOLING CFR%110, 0 I 1.----.... 0 CAUTION-OPEN ALL DISCONNECTS I •. .•NOMINAL COOLNG CPA X 90, :. 45 D•ILA BLU.,.....1V BEFORE SERVICING THIS UNIT .•• . nBLU, DELA, A-STANDARD 1--I mm , ...1 . B-HUMID CLIMATE C•DRY CLIMATE O.TEMPERATE CLUATE 1--1' 858751-UVVD-A-0512 ] CO 201. 41. , , •DA •• 43. C) ! 1 , 0 i .r.. aI �, (31 .4. Z -I p G) c w 2 COOLING UNIT WITH GAS HEAT n^G D FOMER SUPPLY CONDUCTORS6036BUSE ELEMENTARY DIAGRAM A —.''COPPER CONDUCTORS OILY • CO NPR Ill—YI Mt I I AU%ILARV LIMIT SWITCHND TEMPERATURE CONTROLS-DNO /1 Intro • t21�BN FQ—t00/BI(J `5 GROUT BREAKER UN 'PS 'a0 r1NG iEMPERANOE 1DELiF- \O/ t7J el \ IT SIZE DEVICE CFMCB GPM MER COMPRESSOR BOARD CLOSE 0 VII I I O ,an��F-p Mi Q DM DRAFT BOARD x0 Be j CFMCB A I ' HP GROUND H PRESSURE SWITCH OPENS•625 PSG 030-0B36 is 0 LO :• BLNODFAN ODOR FAN MOTOROR MOTOR CON ALS COAW KI 41 x2B/BN •—• • BRN OCOND R( ,p5i8t LOIMCB W PRESSURE SWITCH OPENS;ol50 PSI AO38BE LS 3. LS LIMIT SWITCH ]u IM • x32/BL O®O 231BL ®-y-Y PRP °M I CONTACTOR.COMER AND mFAN3 TUBE C Po i y OD OUTDOOR FAN MOTOR �dAg RLS -PO 120 C ED 2P/BK MiP ^ ,�^� PS PRESSURE SWITCH V W CAPACITOR R9 ZIO 1,,e•- HP O RS2� ROLLOUT SWITCH 04 TUBE 02MB _• -_ I�Iww • INAL BLOCK CI LP TB 1RANRMSFORMER.2AV.ably5 TUBE 210 _ - VI �a9 2E2 p�TB,DI T2' TRANSFORMER NOV.a60v Op6 ALS '.SO 2 - O I] �6_�)-cmourAYr.BK 5 IM B `\I '-;.1 CO a— — ,} HEATBK 1 60 m,w �� x — —FIELD WIRING VI IP9 e I 55 5 m —••—-•—OPTIONAL WIRING AND DEVICES Ele - �cpauBL 5— —2Aw/BK— I_ _ a q FACTORY WIRING AND DEVICES CD' , 16 1}G2,BR c _3 ?—2.w/BK CD ©---11--6 1)—C1GR ( _, 3 )-,L I,. a)coal I 6 y-Y,n ( — IDFAn O©QO OO O NOTES. Cl) 12 I,�—NR biz�z O 9 R A s tn`LFE WIRING TO BE CODTCCO'IN FEci ACCOMPLISHED FOLLOWING PALE aF INSTALLATION DHEAT OF TNS UNITIN 444. g^ I ,n I,rv2/O a 222/R 2.CAUTION'.LABEL ALI WIRES PRIOR TO DISCONNECTION WHEN SERVICING € 0 3 2C8/O 236/0 CONTROLS.WIPNv ERRORS CAN CAUSE IMPROPER ANDTHT DANGEROUS A OPERATION.IF E WIRING AS SUPPLIED WITH THE UNIT ;�I,9}BLUWNTM2 , 13 EMCB OO MUST BE REMOVED IT MUST BE REPLACED WITH TYPE SOS DEGREE C. E ADJ L.0 = ti.4.41.AP, VOLT WIRE OR EQUIVALENT CLEARLY RENUMBERED FOR IDENTIFICATION C VERIFY PRCPER OPERATION AFTER SERVICING. ET EA . - ,�—G,pR 5 w € I 4�I)-DELAV/N �A ..a/ rws RRwr °NPR— <.MOTORS ARE INHERENTLY PROTECTED D —�.AC}-0, REMOVED DEUY �-SM Nam" 5.REMOVED I )=I Z]—AOTUSTN �6 B �,y-A'' T 6. EUNIT NAMEPIATE FOB MAXIMUM USE AIO/OR GRCUITBRFAKERS20E < D t CFM OTTY.BK . i ^ ^ 2��R n�. AND MINIMUM CIRCUIT AMPACITv 0 D r121/BR WHi/WAN �6 1 *1 —Y= EC/Vt VI.T =� I FOR REMOVE I�2_ }225/PR �� —II AT e HEAT I PUMP I A r 229fI ®r ry 2t5/R CONTROL BOARD SETTINGCOMBUSTS a I�228'W n RBIOWER HEAT ON N BLOWER DELAYE3USECC 60 4 - 3 R R�� pIs NOOOR BLOWER C00.CFF DELAY:32 GEC gp r 23y �Ty\j (tiT(1205/ly INDOOR BLOWERHEAT OFF OEL1Y fElD SELECT O yp _G fir I - .+ I STRAIGHT LINE INDICATES SWITCH POSITION • 5— 0 fi :. 1 STM O ,60 SENSEPS 2N/PR�rO1s1 1 CFMSELECTOR BOARD SETTINGS • O COOLING A•• ARI RATED CFM yAORNEI S C.G FEE TE TERATURE I— 0 OR ADDITIONAL INFORMATION ��IwT 1_ y 246�Pft� --� i AL O MFATMG A-H HEATING C M I s OAS VA E i 0-FEE TEC TERAIURE REE REE A� -OR ADDI NAL INFORMATION �BLK BlN " 1 Al. A.NOMINAL COOLING CFM Orr 0 ` D-NOMINAL COOLING OEM X 901A ,5 n.s uE0 1M1� D 4 DELAY A.BTAnDPAD BL BLD CAUTION-OPEN ALL DISCONNECTS o ? B.HRYCLIMCLIMATE 1 ) = BEFORE SERVICING THIS UNIT CO DRY CLIMATE (A -TEMPERATE CLIMATE 857271-UWD-A-0512 C e 6i/BR • i • 0. 1 C () is Cn o ., � 0 0 7 — C) . v o z 7 • Q o CD co .` O COOLING UNIT WITH GAS HEAT COPE CONDUCB618OM.Y ELEMENTARY DIAGRAM n COPPER OILY Q �F A ' COMPR — I Q M I � LEGEND TEMPERATURE CONTROLS ONO 0 IIil ,21/BI( E{� ALS YOAT SWTCH ,00/ CB1 CIRCUIT BREAKER UNIT OPERATING TEMPERATURE(DEfRF T1 ®© ,23� COMP COMPRESSOR BOARD T512E DEVICE ppEN .r CLOSE CO I V i MI I I PRESSOR OBILL 1 G) '10/�Y DM DRAFTBOARD 3TUBE fEE(( OMCB , n t28rr�� ©MI W EMCBR ELEC.BLOV.ER MOTOR CTPL.O 0� Q ` 1 ',EL �K GNO GROUND dT�UBE n ` CFMCO A 'B C 1] R OOp� MOTOR SWIITCH OPENS 0 625 PSG ARSU 03 COMP an La BL _ ® :NCB FIDOOR MOTOR CONTROL BOARD saeo / K,ro� 228/BK 331 — SVRE SWITCH OPENS @50PSISLS LIMIT ,SO 2 -� 7 ��CC__,,mmuu--iiww._TT1�I� DM MI �S M C. 232,0E CONTACTOR, AND OD FAN 'w OUTDOOR OR CON V I El:, 29,BI( PRP O ODFAN MOTOR PS • • NROLLOVi SWITORCH CONTROL BOARD RS • TB TERMINAL BLOCK C TI e El �ARSFORMER.24V.450V LP R TRANSFORMER,240V.480V ,,,wx p= 2 {1 1:3 fx_I y-.�FM«,T/WT-BK @71 II FEBn q I�5 ID—HFAT9N � Q, —„ n l` ----- oNWALMIV/�RING AND DEVICES / I _ )-COOL/BL t 5�5�--2,GVIHK— L— $ m R R — FACTORY V VWIRING AND DEVICES / 2,1 QO p2 = I a)--C2.BR 0a 4-0—240V0K y Ei coa I 6 I}Ym @ ...., 4 IDFAN I AO 12 ,1 —RR LS2— R-- NOTES: I NN RR j 2— O 1 ALL FELD WIRING TO BE ACCOMPLISHED FOLLOWING CITY.LOCAL S( p D/OR NATIONAL CODES IN EFFECT AT THE TILE OF INSTALLATION S UNIT O .08 I 9 I �V2l d I tO d 23610 CAUTION.LABEL ALL WIRES PRIOR TO OISCOMNECTION WHEN SERVICING CONTROLS.WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS W 24M0 2OPERATON.F ANY 6 THE WRING.AS SUPPLIED WITH THE VNIT. D 3 1 BLU-NMTNrz 3—,3 EM® 9 BE REMOVED IT MUST BE REPLACED WITH TYPE 105 DEGREE C. O VOLT WIRE OR EQUIVALENT CLEARLY RENUMBERED FOR IDENTIFICATION. q,,, ' I 15 I, 5 — xK:KLIUTIxwT �- VEPo PROPER OPERATION AFTER SERVICING. O GN ,0703. C I ,- �DELAYR —, --6 — Z, usneurrj, 3. OR ARE INHERENTLY PROTECTED. 0 i D a.REMOVED ORAV I T_ T�--ADJUST —T —{�•p•0~- gf �Ap a�v s.REMOVED m CBI 6 SEE UNIT NAMEPLATE FOR MA%MUM FUSE AND/OR CIRCUIT BREAKER SIZE -. I D — ,P CFM OUTV-BK a—f5 ®° u, 200R 11 fT AND MINIMUM CIRCUIT M,PACITY. I ^ I ,)--2211BR WHTANIWI N ^ �r.1132 Mt�P r 1 F © l IREMOVE �P6 a 225� �' co MX i EAT PNNE FOR 14 �2„ ® . T1— z,sR o CONTROL BOARD SErt • £ 57 r2TeAN INDOOR BLOWER NEAT ON COSIBUSTION BLOWER �IAY.E.HI SEC 30 C OQ O RS LS ALS DOOR BLOWER CO ELAN.30 SEC C 30 I J�—233Iq - '(}_ r-(-}-�(L 205,R TRAKRHBT�L NE INDICATES O�N.F�IDp SELECT O 180 Q' • I 71.11' 2MNR{ I r-s I sE CFM SELECTOR BOARD SETTINGS MEn� '�Jn ', COOLING.A-ARIRUTETCFR tv sw C- aT� O-gOU ory LITERATURE HL ORAL HEATING CRSW 2d5iPR�B�I•i — 7}� ALi i HEATING.A-NOA$INAL HEATING GFM IL OAS VALVE C• �FORTECH LITERATURE L� — S�RE• RE. 4 D. �F ADDITIONAL INFORMATION �Trr BLK ill ' { ALM A-NOMINAL COOLING CFM 5 usEP TTI Bl [ 0-NOMINAL COOLING CFM%1 tPF PPESSURE CD_NOMINAL COOLING CFR X BOX ��-'� CAUTION-OPEN ALL DISCONNECTS DELAY A-STANDARD B K BEFORE SERVICING THIS UNIT -NJ I -HUMID CLIMATE L.INRV CLIMATEIG LU I - 2QS �R i D-TEMPERATE CLIMATEI 857170-U WD-A-0512 • CO 201,BR f H r\ L. i 2 O (0 I —• V •2 3 Co 0 ? CDz 0 KJ 1 I B I C I D I E I 2' G 1 H I .1I N 1 L I A O OOL I NG UN I T W I TH GAS HEAT GAD 20dE230uPPe� ELEMENTARY D I AGRAM ,CON DUOPOER I Q 1 .4. COMPR _ MI ONLY LEGEND TEMPERATURE CONTROLS O ' Eil101/BN IOOIBN ALS AUXILARY LIMIT SWITCH BL o® NCI / CFMCB CGS SELECTOR BOARD UNIT SIZE DEVICE OPERATING TEMPERATURE(DEG FPI 3 0 INN/BP--O-{ I10 Bk COMPS COMPRESSOR OPEN / CLOSE H 1 DM DRAFT MOTOR RS 200 Al2 BL , 0 102/Y MI(� EMCB ELEC. PLOWER MOTOR CTRL. BOARD NEM UB38 LS I40 6 I10 `\ GND GROUND ALS 160 12 HP HIGH PRESSURE SWITCH OPENS 0 625 PSIS 3 TUBE RS --- CFMCB 1,,, IDFAN INDOOR FAN MOTOR 02N-Ole LS 155 6 125 9 .� M I I ODFAN IMCB INDOOR MOTOR CONTROL BOARD ALS e0 2 COMP �I COM LO =LX --- _-_ I COMD RC2 LP LOW PRESSURE SWITCH OPENS 0 l PSIS A TUBE RS 210 4E I LA 23I/et O®O E2,F4 0, :RX 0 104/R LS LIMIT SWITCH 038 S !0 c 20 9 W.; NI MI CONTACTOR. COMPR. AND OD FAN ALS Id0 12 - .= L 232/BL R DM DOFAN OUTDOOR FAN MOTOR RYHP Z M PS PRESSURE SWITCH 45 060 LS 150 6 120 II N M RCI COMPRESSOR FA RUN CAPACITOR ALS Ie0 12 YI 227/5N41 ...1421 1�l RC2 OUTDOOR FAN RUN CAPACITOR AS 2l0 12 �'/Y2 f--Y Hp 22B IBk RS ROLLOUT SWITCH 0 E-000 ALL': ITS 6 '99 9 (13 6 LP TI tPAN3FORMER. 2AV, 230V ca 5 TUBE 15 210 12 --- --- (Ipw LP 0{e-Dc0 ALS I80 IQ --- --- £ o ' — 229/5L OP I TN OUT/WT-AN @ S� IXCB n al r�� ® III I I}-NEAT/BN El mmII ___ —FIELD MIR IRO CD p! 35 PS —OPTONAL WIRING AND DEVICES //�.N CM Am S}COOL/9L <5 �S *5� 2M0V/BX iACTORT YIRIHO AXO DEVICES CU \ ( OP2 -1—'—I D--C2/BR �3 —o a—Al 210V/RR OPTIONAL CCH rn II~ P� ID-C1/BR C .N1 3— 3 222/R S/P'C-C-n.,F!II11GBLNTIOM 77 COOL 2 dN..l eI>01/T �B 1OFAN Q••-v--O N v • 1� A _BLk�,N NOTES: •"' C �_R 1) - - EZ�2 D/P CONFIGURATTIIION I ALL FIELD NIP LNG TO BE ACCOMPL ISHFD FOLLOWING CITY, LOCAL N _ ���,,�,,,,�,,,,,,,,//F���_B LX AND/OR NATIONAL CODES IN EFFECT AT THE TINE OF INSTALLATION ,HEAT I _I 2 2 CV,+-'•v--� OF THIS UNIT. IN_ Y2/ �1A 236/0 �- -.I_A��B.�L�N -A Z CAUTION: ONTROLS.LAWERIX6ALL ERROPS C PRIOR N CAUYE DISCONNECTION AXD OAWHEN GEPUl SERVICING N I C I A 2Md10 �--Aiy MYSTABEOPEMOVEpOOT MIFISiMBENREPLAC EOSWSTHPTYPE 105xDE6PEENCT cm..) 1 1N I)--BLU-WNTIW J�IJ FMCB ® WON VOLT WIRE OR FW IVALENT CLEARLY RENUNBERED FOR IOENTIF:CATION. 0 A0L I 19I I�--6/P 5�15 s :I?NAN LIAIT INPUT -0-, VERIFY PROPER OPERATION AFTER 9FRVICIN6. 3. MOTORS ARE INHERENTLY PROTECTED. 0 W� }-DELAI R A H.M 6 ROLLOUTI 06A.AElATT Q FACTORY WIRED FOR 230 VOLt OPERATION. FOR 20d VOLT.MOVE10>/PP en [ D WIRE TO 20d VOLT TERMINAL Ox TI O DELAY IT�I T)-ADJUST/P T �T 12.VA0 1—(Lp�RNN'«f A— 52Elk -CH,A. - © SHUNT CONTACT ALSO USED WITH CRANXCASE HEATER:OPTIONAL: it O L Id J It--CPM OUT/T-BN q ale Ng Me NIMUMNCPRCITIETFANP^CNTYUN FUSE AND/OR CIRCUIT BREAKER SIZE MUT cc r 7 1 }22115R HT/N/WI li P m.T l CC AT REMOVE P6 2 2-2231PR e?. /�I--�I cm/1 —• HEAT PUMP a_l 4-23A/T ®I I-1--I NEAT I-- I CONTROL BOARD SETTINGS: p S.. 6}2261N I� CNDOOR TION SLOWER BLOWER HEN TPON DELAY 3JO SEC SEC o 6D (Q �II r� INDOOR BLOWER COOL OFF DELAY: J0 SEC % 90 v 230V 06V L 3 J 3�-23]IR f--2 I RI DOOR TPLOWERLINE NEAT OFF DELAY:FIELD SELECT O 120 �y9 `A 0 TI STRAIGHT LINE INDICATES SNITCH POSITION 0 ISO MI SNP !s VJ 1PS ANE Wm 2A SEC GAVV VALVE 1. CFM SELECTOR BOARD SETTINGS 7)-344/PR-Q ER O ` BLA MV 3 Q COOLIR6: A _NOMINAL COOLING CFN T9{Y9FOAN C-SEE TECH LITERATURE AN - i D-FOR ADDITIONAL NFORMATION a! 11-< /11,7 n 2X5/PR-@�-11 �}I H., 215/ BLU PV/MV (A HEATING: A-NOMINAL HEATING CFM PI LR. I 0 -SEE AE<X LITERATURE '4{f AA}T E D-(FOP DOITIpXAL XFOR NATION cm, - L--9 RS LS LS LX 1--(}t�_203/ I (•-) ADJ' B-NOMINAL COOLINA CFF'M X I101 rl-S usNiEoOroT I _ J- MUNK C-NOMINAL COOLING CPA%90i �5 IPA— I DELAY: 0-N/ANDARD @5 BL CAUTION - OPEN ALL DISCONNECT, I p 8:HUMID CLIMATE k I� PAN BEFORE SERVICING THIS UN I T D-TENPERRTE CLIMATE G 2 7 6 3 9 I A REV D C 201/BR 2 sv q m I CI 0 is C 1 '0 cn U I C- o 0 d ZO EE 0 o N 1 fn i. I A I B I c I_ D I E I F I G L X I J .I X I L I 1 POWER SUPPLY 0-1-60 ELEMENTARY DIAGRAM o COOLING UNIT WITH G A S HEAT DND USE/COPPER D COMPR CONDUCTORSO TEMPERATURE CONTROLS DANT Z STAGE UNITS TEMPERATURE CONTROLS DANM 2-STAGE UNITS O l CI) 11S I 0 IDI/BN MTAZ . N 100/BN UNIT 512E DEVICE��y EMIE11=IDES C1 NN IT SIZE.,,,cE onsE7 NB TEMPERATURE sUN Cf E M. l� RC , o2A EI59 NO�12 OS EZA oP[x i. •._ ' I N © 103/B se 12o tT0 .i BL ` xI 73 Q © 102IY 4 L. INN 25 NeLs i 40 . = ne • e.g ALB lao lR e4 F CAM FON [J ' 0 CORD ODFAN L 4______I •L is `a Ito 11 0 40 se R�B i 3e ,:: —_F 231/BL 0®0 ELF! LRNCDI 0!/ DM 0 Ae `i 232/BL Z A IMI IT/rz�F—. ue/0n r� • 10///�N I N P ' r L� LEGEND 3 VI 229/BL ALS AUXILARY LIMIT SNITCH ( 3 �P3 7,-o 9}-c Fu out/NT-DK 0 Sy NCB z m CoomCR. CFMP SELECTOR BOARD CD EH— p9 ICI I)--NEAT/BX QI III as PS EMCB ESSOR OM LEC?EBLO ER MOTOR CTRL.BOARD (D j MOTOR 0 I © 5n S)--COOL/BL 05 —S 240V/BN HP D HIGH MPRESSURE SWITCH OPENS N 025 PSIG y ] !DEAN INDOOR FAN MOTOR = 1 QO P2 3.m 13}-02IBR 03 —3 0—A) 290V/PR IMCB INDOOR MOTOR CONTROL BOARD CD 1� 1�1/Bp /' LP LOW PRESSURE SNITCH OPENS W i PSIG I 1 y 11 3�3 222/R LS LIMIT SWITCH M ' 2 �g IDEAS I CONTACTOR.COMPR. AND OD FAN E COOL �Y1/V C ODFAN OUTDOOR FAN MOTOR N 12 \\ /R FZ^2 41 ® OPTIONAL<CH PRCI PCOMPRESSORWRUNHCAPACI TOR 0 MEAT 2� 12l 'l S/(P)NCKC�ME-(I'yGB_LTION R32 OUTDOOR SW/I TCXN CAPACITOR W I C 12 I I)—T 2/ !awl 236/O I` BLX�cA TI TRANSFORMER.21V. 230V 0 248/0 --- —may NOTES: I D_ 1S 1)--BLU-WHT/W 3 mm13 = EBB D/P CONFIGURATION ALL FIELD MAINS TO BE ACCOMPLISHED FOLLOWING CI TV. LOCAL AD! HISS LINT,SPOT n„�.,,/-tiG LX0 o`DTDRSNUNf$NL CODES IX Ef FECT AT THE TIME OF INSTALLATION C IS_I I�--N/P 5 CIS ' 'LNi0 YMc9ELrY VI-._NL� 2. CAUTION:LABELALL MIRES PRIOR TO DNNECTION WREN SERVICING D Mn ,D--BELAY/ / �! CONTROLS. W.I.ERRORS CAN CAUSE IMPROPER AND DANGEROUS $UN2N I_ TIRUUX OPERATION IF AN/OF THE MIRING. AS SUPPLIED WITH THE UNIT. 0 I ® BOO TVOI TRWNOEEOA EOUII VAL ENTRCIEAOIY WITH MBERED IFOR IDENTIFICATION. 0 I € ADELAr 7..1 1.)—AD.IUST/PR i �i VERIFY PROPER OPERATION AFTER SERVICING. M LOR F ..,. eF E D L IB J I P�---CFM OUTIT-BA g..10 �f1,,2ELNET 3. MOTORS ARE INHERENTLY PROTECTED. G I -221/BR NT/N/WI— n �� 4L WAKE TO 20 BEVDOLTATEAMINAIToMATION. FOR 208 VOLT. MOVEIET/PR '. REMOVE E Pat 2--225/PR —ppff H.tcmU I QS SHUNT CONTACT ALSO USED WITH CRANKCASE HEATER IOPTIONALI = i PUMP 2 —23!/T ®T y2 IIWA1�—�S HEAT g. SEE UNIT NAMEPLATE FOR UOSINUM FUSE AND/OR CIRCUIT BREAKER SIZE (0 j AND MINIMUM CIRCUIT AMP AC ITY, v a Bey ID--OUR/W �I INN I — —FIEIO WIR11W ( t 3 ,3}-233/R L �y p }IRO{ 2�V�2PT O —.._-.—OPCTONYLV RING AND DC/ICESS co 1 Mn 5}-235/BL -CO �-I-' ILI - TI t!V SEC CONTROL BOARD NETTPINGT d 7,, I = iSVA CWBUSTIOX BI OWEA OSTFU RGE: 30 NEC O 50 e 2!!/PR{311� FF L.MM sOnC INDOOR BLOWER NEAT OFF DELAY- 30 SEC 8 DOOR BLOWER COOL F DELAY: 30 SEC CFM SELECTOR BOARD SETTINGS ER O INDOOR BLOWER HEAT OFF DELAY:FIELD SELECT SD STRAIGHT E INDICATES SWITCH POSITION O -- 1 + COOL I NO: A-NOMINAL COOL IMG CFM ru.11 ', \ O ISO I3 j C-],SEE ADDI LI AL V/RE AI r+--��1 .72 - D-fOR ADDITIONAL INFORMATION 2M5/PR�B`1R 2 spit:}— r 213/ HEATING: A-NOMINAL HEATING CFM 11 - C �S5EE^ECH LITERATNRE �� t- LS AL D-FOR DDITIOXAL FORMATION AM IAAwxT�T� III RS ADJ: A-NOMINAL COOLING CFM USS roA X 203/p ()---I I B-NOMINAL COOLING CFM X 1101 uF I C-NOXIXAL COOLING CFM X 901 CS PI NI 1 —YEL j D-N/A DELAY: A-STANDARD LU CAUTION - OPEN ALL DISCONNECTS B-HUMIDCLIMATE _ �f BEFORE SERVICING THIS UNIT C-DRY CLIMATE lc 201,BR 2J G 2 6 8 5 I 7 A R E V D co 1 0-TEMPERATE CLIMATE Ul 2 v CD .A i N AG V - 75 A n 41. 'y A Z i —I ( O E_ I A I a I C 1 D I E I F I 0 I H 1 J 1 N I L 1 cr) l 0 COOLING UN!T WITH GAS HEAT POWER SUPPLY © I A X° 208/230-1-60 ELEMENTARY DIAGRAM USE COPPER CONDUCTORS ^ CDMPR - MI ''ONLY LEGEND TEMPERATURE CONTROLS l/ p I01/GX ®I1 10p/GK� Als nU%LEANT LIMIT SWITCH YL qCl CFMCB CF.M SELECTOR BOARD UNIT SIZE DEVICE OPERATING TEMPERATURE IDFG 0": 0 BL l�© 103/BP Q I106/R� IIOIBMr COMPR COMPRESSOR OPEN /- CLOSE I- Q DM DRAFT MOTOR RS PE T12 MT , 2 TUBE LS It0 6 Ilp T9 0 IO2/Y ©II(� EMCB ELEC.BLOWER MOTOR CTRL.00ARD Oia-03e ALS L-----I YEL I(JI[\ 6Xp GROUVIM/I D P j�—�L'�B OMCB ;LqHP NIGH PRESSURE SNITCN OPENS W 62S PSIG }{UBERS �QCFMCB AK F L I IDFAN INDOOR FAN MOTOR 024-036 LS IGO 6 130 9 COMP HI CAM LO ;pp NCB INDOOR MOTOR CONTROL BOARD ALS UTS 12 --- --- C CONS LLP LOW P LIMIT SWITCH OPENS W T PRIG 10 UNE LS 2t0O 12 130 9 3 333 I' IL 23I/BL 0®o E2,F1 36 16 6 ti XI OOFAX DM MI CONTACTOR, COMPR,AND 00 FAX ALS I60 12 --. --- 7iiii 232/BL ODFAN OUTDOOR FAX MOTOR J TUBE RN ISO 12 G CEO NP q OMCB OUTDOOR MOTOR CONTROL BOARD OtB-O60 LB I50 e 120 9 C, l'� PS PPES SURE SNITCH M YI NP- 22]/BX v 'RI COMPRESSOR RUN CAPACITOR t TUBE RN 2]0 I2I --- - S /12 22 ® AS ROLLOUT SWITCH OIB-D60 ASS Iga tX It5 9-71 ,^ TI TRANSFORMER, 21V, 230V 127 -- -- V, R El: ' 77 Q LP 229/BL LP 0UO BEO ALS ?ES SO I�2+ i39 -9- www L C:PSI I- 0.0 B�--CPS OUT/rT-BX 0 S� IMCD . QI I IP91_ I�--NEAT/BX (I�1I SS PB - TiON�LRW�RIRS AND DEVICES SU 5W. .}COOL/BL / 5 5.4 5D 2d0V/BX FACTORY VIRIHG SAD DEVICES (Q CD QO P2 } 13�--CAIRN 0 *N t*D 240V/PR OPTIONAL CCN Et NC I1--C1/BR Q �1 ). 39 222/R S/P CONFIGURATION N r,� _ IDFAN VV-"��++ BCOOL 12��6�Y1/I �6 _ L--_BLN� NOTES: D I -A/R (2.12 ® 0/P CONFIGURUTION ALL FIELD WI RIN6 TO BE ACCONPLISXED FOLLOrING CITY.LOCAL BLN AND/OR NATIONAL CORES IN EFFECT AT TXE TIME OF INSTALLATION d x EAr z� z� z Q"C/`v✓d � of rHls ux rt. ,..' A Its TSI �1M ANN/0 ---BL 2. CAUTION:LABEL ALL WIRES PRIOR TO DISCONNECTION DANGEROUS SEPVIC IN6 N C I� d CONTROLS. FOR ERRORS CAN CAUSE IMPROPER AHD DANGEROUS 218/0 .-._NI y-. OPERATION. II RT OF THE RI XG. AS SUPPLIED WITH TXE UNIT, o D— I3� I}-OLU-WHT/W2 3..13177' EMCB k �^ZD© ION OOLTRRIPEEOP EOUIIVALENTRCLEARLY RE/COWERED FOR IDENTIFICATION. I S ADJ I3 9 RIDS 11011 INPUT VETIFY PROPER OPERATION AFtER SERVICING. I N - S U— <� dn]--O CLAY/ d *< _�G I1 wrvi(iYiPiu 00 AY Q MOTORS ACTORYARE RCDNFORN2R VOLi PROTECTED OPFRATION. FOR 20G VOLT, MOVE101/PR 0 DELAY 1_I i�—AOJUST/PR ] �T I.'.~�4E� IWR20 MIRE TO CONTACT VOLT TERMINAL OM TI. [ SHUNT CONTACT ALSO USED WITH CRANKCASE NEATER IOPTIONALI I�]I)--CFM OUT/Y-ER 6*6 ttT Y 6. AXE UN„TMUAMEPLAYE FAN AA0INUM FUSE AND/OR CIRCUIT BREAKER SIZE o D r P6 D N N CIRCUIT P CITY. I I t }221/11R xT/W/NI YI IcaT 1 < e REMOVE P6 2 2�223/PR ®i f�-IJ�1tH� 00L O I *. ;� NEAT P �R }23t/T - 4) `j�-�MEAT I LOT/PR 5 CONTROL BOARD SETTINGS: 6� 6}226/W f7tf—I I. I COMBUSTION BLOWER POSTPURGE: 30 SECINDOOR qELAY. 30 SEC O 80 I `^ L ',..1 J Wf ^ 230V 20 GV NDOOR BLOWER CWER OOL OFFT ON DDELA: 30 SEC 0 90 ]�233/R Ir{, Y-�7 Ty C INDOOR BLOWER NEAT OFF DELAT: FIELD SELECT O 120 = 1 5.. S, ®p IL Q TI STRAIGHT LINE INDICATES SWITCH POSITION O IGO t4V SEC PS 2tUPRLJI- F )_ 1 PG I FUME MU a ]]VA _0 L CFO SELECTOR BOARD SETTINGS .q ALT O = COOLING: A-NOMINAL COOLING CFM iiilAi3POIDR e ,R GAS VALVE CC S B- RED PV C-)DEC TECH LITERATURE 1I5/R SUP NV N -FOR ADDITIONAL IRPATNOTIOX 215/PR4—4I P ] « O HEATING: -NOMINAL HEATING CFM �R1 M1 A ,RED -SEE TECx LITERATURE 0 ttf A1� ll n 3 D-�F OR ADDITIONAL IXFORNATIOX WN�gI1�XTr `-ELK - R9- -LgU OB/N AL BL PVIMY " 2 ADJ: -NOMINAL COOLING CFM P1) KtOT �"Y�J�(`�- —(`Y�eA i"}-2 ° p_NOMINAL€OOLIN€CFMX90.3 c6 000'NN I) CAUTION - OPEN ALL DISCONNECTS DELAY: -STANDARD BEFORE SERVICING THIS UNIT LO `_opal"�""rErE �� L2 G276395A REV D D-TEMPERATE CLIMATE I C 201/BR D a c 0 W 0 AG -o. o o m v o X p 0 EA I A I B 1 C D I E 1 F I 6 1 H I J I X 1 L I O) C COOLING UNIT WITH GAS HEAT POWER SUPPLY o tW1230-1-6D n "° .USE COPPER ELEMENTARY DIAGRAM CO CONDUCTORS ITEMPERATURE CONTROLS DxNY 2-STAGE uN TS TEMPERATURE CONTROLS DANK 2-STAGE uN TS ^ _ ONLY 0E MPFRAT x TExPE110=IOFN F-I ux T ENT TERPERATURE I0E0 r.I C') COMPR Q 101/5K ®III(� 100/BX xx lT 3 iE 0[ OPEN / i iC OFV ICE OP oP[x"R �.� L �� NCI I10/BA� 021 ZNX •Ii Alx ... -. 0 Q 103/BA 101/ BL , O I(� R� NI 0 WXT O 10211 I ©II eJ1 n. 7 OMCB :LN \ - (O 0 CFNCB ...Tr aP PIR r�-h COMP CON LO ... .-- N COND "" ale aP OIa 0 I II �- 231/BL 0®Q EP.FI ![ --- -_-- A[3 I1, IR --- --- RI K1L - ODFAN OM Oie NPie %3 M 1 232/BL IIR --- - I cC Ali li -f m. CINP 22T/Bn- y-P��J�II M /\J 3 ,, �H " _ ME 22y/gRJ -1 A r-- lP P NI R3 2E9/BL LEGEND 0 ALS AURILARY LIMIT SWITCH eel U-CFM OUT/WT-BX @ ss 8 1MCB :T.; cFAKe cFM sEL EctDR BOARD � W COMPR COMPRESSOR IIWx �--NEAT/BX (I..11 DM DRAFT MOTOR PI 1 11 SS PS GEmCB ELEC.ND GROUND LOWER MOTOR CTRL. BOARD E Ea5=5 3D-COOL/BL (3_3 5 V 2A0VIBX I F 0 L 'J HP HIGH PRESSURE SWITCH OPENS 0 825 PRIG ^ j aP2 3 �2/BR (J S 1�) 210V/PR I°FAN INDOOR FAN MOTOR V, 2 � IMCB INDOOR MOTOR CONTROL BOARD 0 I ems II I L .. '-Cl/BR ( .m1 3�Di LP LOW PRESSURE SWITCH OPENS!)P510 (/�. ID K2 LS LIMIT SWITCH T g coa IDFAN CONTACTOR.CONPR. AND OD FAN 1 1 A I ! 18�-YIIY �B �I = N ODFAN OUTDOOR FAN MOTOR CD 3 A 12 I R/R (2..2 I� ONCB PRESSURE RWITCN [� D HEAT 2� 2� 2 S/P COMGIGURATIOX :CS' COMPRESSOR RUX CAPACITOR N ! p I)-12/ 1 CIA — I Cwio--"(�I TI TRANSFORMER. 21V, 230Y 0'38/O D_ 13� C)-BLU-MNT/W 3�13 2A6/0 `--_BL"-0 MOTES: CO � ADJ IB `{! III.LIMIT Ixn E"CB D//PP CONFIGURATION ALL FIELD MIRING TO BE ACCOMPLISXED FOLLOWING CITY. LOCAL 0 9 1�}--,,6'P $ 15 '',. y[N[LAI 9,V3/'QBL"�I OI°THI"5"UNI AL CODES 1X EFFECT AT THE TINE OF INSTALLATION U_ 1- >'OELAY/R mm1 LWronl ttx BLX 2. CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING Ivu—CaTI RISSS at OPERATION IF ANY IRING ERRORS CAA, HR"SUPPLIED"MIDA"THE°UNIT. Q) DELAY T..1 1>—A5JUST/P A mml a[lFOi w® 6UOTVOLT"MMPEEORIEOUIIVRLCNTRELEARLDl REXUMTOREO FOR IDENTIFICATION. Q A C L 11,ly--..FM OUTIY—BA G SIB VERIFY PROPER OPERATION AFTER SERVICING. D 'T PB F` 3- MOTORS ARE INHERENTIi PROTECTED. ® I I`i }221IBR xTIWlW1I l70Fr ER."�rt Ix 0 , FACTORYF WIRED FOR 230 VOLT OPERATION. FOR 208 VOLT.MOVE OT/PR 0 REMOVE PR s 2D-220,11 ®, IT...{0,0.� IRE TO 208 VOLT TERMINAL ON T1. P IEIMP 4.. 1}23t/T €' MO. IDIIPR N. SEEN UACTX NAMEPLATE FOROMARTMUMR FUSE AAND/OR HEATER C RIRCUIIT BREAKER SIZE I/ 8t.-228/N AND MIXINVN CIRCUIT AMPACI Ti. y J f�T,x-{�.INC 230V PBV ___„—FIELD WIRING O Y L J�-2331R W-�-M-I NR j li m RI Ti —FACTORY LWWRMXGOAMD°DEVVCESS iS SWx 5}-235/BL 0" I LI PS r [ _ 216 SEC d y 2AA/P,,13�- [F[ I - 13VA COM TAOL BOARD SETTINGS: O R} "�F R OMBu5TI0N BLOWER P09iPUR6E 30 REC 60 (� <FN SELECTOR BOARD SETTINGS LA INDOOR BLOWER NEAT ON DELAY 30 SEC 9 1 DOOR BLOWER COOL OFF DELA,: 30 SEC C 90 COOLING: A-NOMINAL COOLING CFM TX O DOOR BLOWER HEAT OFF DELAY:FIELD SELECT O 120 Rx i 100 C-SEE TECN LITERATURE AaFOAMA W 215/ STRAIGHT LINE INDICATES SWITCH POSITION O -- e- N D-FOR AD0ITIDNAL INFORMAroN - HEATING: -NOMINAL HEATING CFM 2A5/P R+;!�I P 1 G-)BEE TECN LITERATURE N2 P1[ IDE, a D-(FOR ADDITIONAL INFORMATIONMMM[[ _'-1t ��RR AOJ: -NOMINAL OOIIXG CFM jjlFlSW�T LX AS LS 0S/ AL B-NOMINAL COOLING CFM IIOR PI-5 ) -NOMINAL COOLING CFM%90i OAR {NI----.. I —YEL "'" CAUTION - OPEN ALL DISCONNECTS i DELAY: A-STANDARD eS _ L BEFORE SERVICING THIS UNIT B-HUMID CLIMATE , C:DRY CLIMATE FI O TEMPERATE CLIMATE r�0 I 2-I 2D[,BR G268908A REV D I co A 4. v o i CA) - A' t I 11 !. v -< X 0 { 0 _ a Ca EI A B C D f POWER SUPPLY 206/230-3-60 F G H J IIL Q COOLING UNIT WITH GAS HEAT 4" USE COPPER CIONDUCTORSONLY ELEMENTARY DIAGRAM A A COMPR MI LEGEND TEMPERATURE CONTROLS Q 121/SX I CT"1 100/SN I ALS AUMILARY LIMIT SWITCH /� l/ BL �� CB CIRCUIT SELECTOR BP UxIT 512E DEVICE OPERATING TEMPERATURE EDEG F') O III BL , Q 123/BL MI 11B/Xn CFMCB cFN SELECTOR BOARD u TUBE OPEN �l- CLOSE •/- i OM. COMPRESSOR RS 20B 2 OM DRAFT MOTOR LS 1E 6 110 9 WHT Q 126/T--M-M Ft()-- 3A-OJ6 BLU EM ELEC. BLOWER M0t0A CtRL. BOARD ALS 160 I2 -- --- = { IEL Ln CB GXD GROUND 3 TYDE LS p0 I]0 C li CFMCB I. L L+ im'R HP HI6N PRESSURE SNITCH OPENS Y 925 PSIS OLI-039 1 N 5 11 CON ODF AN_�0 IVAN INDOOR FAX MOTOR ALS 160 12 (( COMP NI COMO O _ INCB INDOOR MOTOR CONTROL BOARD 1 tUBE RS �� 231/BL O®Q E2,F1 c LP LOW PRESSURE SWITCH OPENS Y i PSIG yap LS I60 6 13D 9 ((( NI ® LS LIMB SWITCH ALS 160 12 'f =� 232/Bl DM MI CONTACTOR,CMOTOR AND OD fAX 3 TUBE RS 150 12 .29 --- C. p1 P ODFAX OUTDOOR FAX MOTOR pIp-ypy LS I30 6 t20 9 C 11 VI i2T/Bn—{ l� OMCB OUTDOOR MOTOR CONTROL BOARD ALs OVA 12 py HP _ --J 1 v PS PRESSURE SWITCH E PS 210 12 3' /TY 2 228/BN RS ROLLOUT$Y IiCN 0 B O60 L3 115 9 115 9 { r�--,z�� - TI TRANSFORMER. 29V. 230V ALS I60 12 Iw 7j {[ `^ LP 3 TUBC RS- 2T0 12 N LP 016-OBO AS I60 6 130 R 1 �P3 229/BL L9 BO 1P --- --- CC 1 (= I r eel pp}CFM OUT/WT-RX �a s� IMca m C/D/V P9 0.-XEAi/BN QI-I J GIELD WIRING rY - S5 PS OPTIONAL WIRING AXD DEVICES a © - s— 5}C0OL/BL 0 �5 5—4, 21DV/BN FACTORY YIRIXG AND DEVICES P2 � .-=..I(a-cneR 0mm5 1-D240v/P" C Il , I� (a--CI IBR 0 -1 M Dia CDOL tNL t N.-I}.YI/T ( - DFAS N 9 ® NOTES C I -2 I -R/R Q2�X2 ALL FIELD HIRING TO BE NEFFECISXED FOLLOWING CITT. LOCAL (� D I I AXD/DA UT OXAI CODES IN EFFECT AT THE TIME OF INSTALLATION M x=AT 2� 0 L OF rNiS UNIT.i 222/R 2. CAUTION:LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING p 1-I I�Y2/ 1-11 236/0 CONTROLS. (RING ERRORS CAN CAUSE PROPER AND TH TI/PODS N U 246/0 OPERA TIORE IF ANY DF THE WIRING. AS SUPPLIED WItN THE UNIT, 0 I3x. 1 -BLU-WHT/W2 3-13 I GUST BE REMOVED IT MUST BE REPLACED YITN TYPE 10O pIDENT IDENTIFICATION. OD L� EMCB ANC 00 VOLT WIRE OR EQUIVALENTENT CLEARLY RENUMBERED FOR IDFMTIf ICATIOX. ADJ IS_ - nt.tI x1T Ix2RT �- VERIFY PROPER OPERATION AFTER SERVICING. El ' I 1)--G/PP 9-15 _09 - i T.Ig' " IBT/PR— 3 MOTORS ARE INHERENTLY PROTECTED. W 111 C 1- 0.-DELAY/ 1 -1 Q FACTORY WIRED FOR 230 DOLT OPERATION. FOR 200 VOLT, MOVE101/PR C TpN F,t.TCM.6 0-IEN 230V•Q AT YIRE TO z0B VOLT TERMINAL OM TI. Y I.. 3)--ADJUST/P 1 -i 2' F Ut _ RI (� p IAT��11 Q O 3. REMOVED c L__J I)--CFM OUT/Y-61 N-16 ®A SFLLtt TI 200/ C 9. SEE uXIT NAMEPLATE FOR NA2INUM FUSE AND/OR CIRCUIT BREAKER SIZE y r' _ 21V SFC 3.L ANP AXD MINIMUM CIRCUIT AMPACITY. C: 1 I)--221/13 NT/Y/YI n law I iSVA < R1OH E Pe2 z�—zzs/PR ®6 —���")' MPFI 0_ PUMP �1 1�- yz31/r ®Y I ROUT I N 21S/14 C CONTROL BOARD SETTINGS' O C BA. 6--226/w Qfil p I COMBUSTION BLOWER POSTFURGE'. 30 SEC 60 !L DOOR SLOWER HEAT ON DELAY' 30 SEC Q 3 RS LS ALs INDOOR BLOWER COOL OFF DELAY: 30 SEC a 90 L _J 3�-233/R - p� �-� !1-TT� —(1T(1-2pyl DOOR BLOWER HEAT OFF DELAY: FIELD SELECT O I2y =• 5- 3� I IL' I V v ` .7" STRAIGXT LINE XD ICATES SrITCH POSITION O IBO PS mu.NMI CI21M/PR{3 RIB In CFM SELECTOR BOARD SETTINGS CO CQ a COOLING: 9-NOMINAL COOLING CPT FUMO TOAN/DOI.0.PI'6 A '1 Y T ALT 3 N ' HEATING: A-NOMINAL HEATING CFN ~ F -1E GAS VALVE a <-SEE iECx LITERATURE ----- F .}.� RE PV D-jNDRAOD1tDXA L INFDRNATION n"N'm ^KU BLN "° CAUTION OPEN ALL D SCONNECTS O AD': A-NOMINAL COOLING CFN F15 IF lice pT B-NOMINAL COOLING CFM M 110i - 7 I „9;1NALCOOLING GFMMBB3 CS " ) BEFORE SERVICING THIS UNIT 0BL P"/NA G276394A REV D 1 0FLAY: -STANDARD 10 UI F. - O B:HUMID CLIMATE ' D-DTENRERA TEMPERATE C 201/BR - 0 1 I. Cl_ c I in E E 0 o ani n = D 0 ', z 7 X 0 O i w cn 1 I A I B I C I D J E I F I G I H J 1 K I_ L 1 C) 1, COOLING UN I T WITH GAS HEAT GNO 2D6E230u3-60 ELEMENTARY DIAGRAM A USE COPPER 7 I CONDUCTORS W ONLY I TEMPERATURE CONTROLS DO.2-STAGE UNITS TEMPERATURE CONTROLS DO.2-STAGE UNITS (U COMPR O - 11 1 UNIT 3130 YIc AiI 0 TEME6ATURF<006 PI UNIT 0ISE VIc OPE[ATIIW TEM ATUAE(0E6 iS /1 121/BN ®• 11 IOOIBN I b OPEOPExA ` floiE R6 OPEN ER<LocE O♦V eL 0 10/SL I10/eR—T— au 0.i[ IZ •-- --- OA i[ 110 iz --- O 0 , in _ AL �� 126IY ©MI-0 I 0 Y --- ■ ■ L TEL ALA oaa Ls t5 -- Jr --- - LO C CF MCS.. •RN TUBE 0aa Lb 11[a _ ez[ o COMP HI CO OM LO _ ODFAN_FO _ --- ... ( C NS 0 iII 21- 231/BL 0®0 E2,Fl ® s [lW oaP TTi K - - °la .Li I-- Iz --- .-- _• 2 - 232/BL 0M UM EEO Pl 22T/BR—(-}'��P- ALL I3a �- /Y2 HP 22q/qRJ 1 LEGEND ALS AURILARY LIMIT SNITCH R W LP CBI CIRCUIT BREAKER - 11 CFMCB CFM SELECTOR BOARD 0 LP COMPS COMPRESSOR aP3 220/Bl Cl)P9 Pl 54 INCe EMCB ELEC. BLOWER MOTOR CTRL. BOARD yI NE r ��O�--CFM OUT/NT-BA q6 ...0 GNU GROYNES PRESSURE SWITCH OPENS O 625 PSIS SD Go-- W. ID-NEATIBN EII—III OF. (INDOOR FAN MOTOR CO IP9 S5 PS IMCB INDOOR MOTOR CONTROL BOARD CD © 5� 5}{OOL/BL �5 �S 3�DLIOVIBK 1, LP LOW PRESSURE SWITCH OPENS•1 PSIG 0P2 -_�_ LS LIMIT SNITCH QO 3}-CV BR 0 210V/PR MI CONTACTOR. COMPR. AND OD FAN y ODFAN OUTDOOR FAN ROTOR Cl) ® — ID--CIlea Q I 3464 -- 0000 OUTDOOR ROTOR CONTROL BOARD COOL N2 G� _ (DFAN PS PRESSURE SWITCH 2 6}TIIY RS ROLLOUT SEEMS C 12 I�--R/A Q 12 Ti TRANSFORMER. 21V. 230V s 0_ ® CD NOTES: EAT • 2� �2 ! ALL FIELD MIRING TO BE NCCOMPLISXED FOLLOVING CITY.LOCAL N 222/R II AMDTOR NAXIONAL CODES EFFECT AT THE TIME OF NSTALLATION CD }Y3l 236l0 OF HIS UNIT. o0 DI_ 13ww M LU-WHT/W mm13 2M/O 2. CAUTION:LABEL ALL MIRES PRIOR TO DISC ONXECTION WXEX BERVIC LNG N - EMCB n CONTROLS. WIRING ERRORS CAM CAUSE IMPROPER AHD DANGEROUS 4J NM LIMIT MUT OPERATIO. F ANY OF THE WIRING. S SUPPLIED WITH THE UNIT. A / �'�--fi/P �15 IrtR xPu MUST BE REMOVED T 5T 9E REPLACED WITH TYPE 105 DEGREE C. o e 0 \ —{ A iOKUi AFLAY T 101/PR 00 VOLT WIRE OR E011 VALENT CLEARLY ENUMBERED FOR IDENTIFICATION. •.. }-0ELAY/A l �1 P i VERIFY RI S ARE OPERATION AFTER SERVICING. W D DELAY �[AYIc—`,[axiae IRa 230V pprV MOTORS INHERENTLY PROTECTED. 3 A DD mn1 D--ADJUST/PR 1 .m T girl. C Q ;;ACTOR;WIRED FOR 230 VOLT OPERATION. FOR 200 VOLT, MOVEI97/PR o FM OUT/T-BN 16 ra�Ir MKT TI CBI ;nil; 208 VOLT TERN NAL ON TI. • G, PS I _ pl r= = giiC 200/R- 4.2 AMI-0- 5. REMOVED O -i-- 1 r221/BR NUT/N/NI P I.RNT1 6. SEE n�xi uAMEPLA TE FOR MAxIMUM FUSE AND/DR CIRCUIT BREAKER SIZE I• ... Ci PO MO N CIRCUIT AMP ACI TY. REMOVE 2}-225/PR �� I--{fml l L." _ PUMP 23l/Y —'-—--—OGTIONAI.KVKRIX AND DEVICES —II—I PLAT N 215/ FACTORY NIRIXGG AXES DEVICES 6� --226/W ry 3� ^ASS P-S LS AL CONTROL BOARD SETTINGS: pLCI L_, 3.--233IR �,- i�ie � --o-T"o205/ COMBUSTION BLOWER POFTPURGE: 3D SEC 0 `• DOOR BLOWER CAT ON DELAY'. 30 SEC — 5)-233/BL r�rs DOOR BLOWER COOL OFF DELAY: 30 SEC 0 {IR .I I INDOOR BLOWER HEAT OFF DELAY: FIELD SELECT O 120 PS a PP SOU STRAIGHT LINE INDICATES SWITCH POSITIONsu CFM SELECTOR BOARD SETTINGS I 2ll/PR{3 PIS- Pi I o 160 1 COOLING: A-NOMINAL COOLING CFM uA O [� B- T D—(FOR AO pI1TONALATN{OR NATION AAwrOA HEATING: A-NOMINAL HEATING CAM 2l5/PR{0=L--JII PI; ;� D-FOR TACO IITERATNFORMATION �I — E� ADJ: A-XONINAL COOLING<FM J•a PAEar. ^—1 a B-NOMINAL COOLING CFM x IIOx AOT LK CAUTION — OPEN ALL DISCONNECTS p_NOMINAL COOLING CFM x 90X SP s Ui[0 1EL C 11— BEFORE SERVICING THIS UNIT SOLAR' A-sTAXDARO G270293A REV D B—HUMID CLIMATE --9LU C—DRY CII MATE D-TEMPERATE CLIMATE1I� --. I f 201/WA 411 , I ' , , 0 CD V O A II i rn K 1a'l 0 A O1 -1j v ^^-1 O 1 V! C.) 1 A 1 A I C ( D I E F I G I X I J X I L Ii O POWER SUPPLY Ae-3-BD USE A COOL N G U N T W T H GAS H E A TXD COPPER CONDUCTORS ONLY ELEMENTARY DIAGRAM LEGEND CORPS _ MI TEMPERATURE CONTROLS S 121IBR ®11 IOOIBN ALS AUXILARY LIMIT SWITCH ii YL �� I CBI CIRCUIT BREAKER UNIT SIZE DEVICE OPERATING TEMPERATURE'CEO r_ 0 3 II Q 123/BL CFMCB <FM SELECTOR BOARD OPEN / CLOSE ♦/ ; COMPR COMPRESSOR RS 200 R12 0 { VNT BL , Q 12NIY-�ti F-d ©XI d DN DRAFT MOTOR 024-036 L. IRO 8 IID 9 7 ALS 0 BLU EMCB GROUND ELEC.BLOWER MOTOR CTRL.BOARD 05 (0 TEL 'LR ONE GROUND 3 TUBE L9 INO N 130 t CFMCB N ,RN ODF AN HP HIGH PRESSURE SWITCH OPENS 0 625 PSIG 024-056 9 IDFA INDOOR FAN TOR COMP XI C. LO Il_ ® IMCBK INDOOR NOTOROCONTROL BOARD A TUBE ALS 160 12 130 .- 3 ML RS 2e0 12 �I-+--231/BL O®O E2.F4 LP LOW PRESSURE SNITCH OPENS 0 l PSIG O38 LS Ia0 6 130 9 LS LIMIT SWITCH ALS 12 232/BL ON MI CONTACTOR.<OMPA.AND 00 FAX 3 TUBE RS E00 12 ODFAX OUTDOOR FAN MOTOR OAB-OBO LS I!0 B 120 rY�1� -� - 22T/BX PPP ® OMEN OUTDOOR MOTOR CONTROL BOARD ALS INS 12 --5 9- I P.0 WITCH ' Np APB PRESSURE SWITCH a TUBE RS 150 12 120 /Y2H� 22BIBK TBI TERNIXALRS ROLLOUT SBLO[K OAB-O60 ALS I80 12 TS i IRS 9 '^ t _ LP TI TRANSFORMER. 24V. 660V RS 2T0 12 V' LP ,,,��{,, T2 TRANSFORMER. 2A0V. M00v :SAT ONO ALS I IBO 2 _30 -- CO t �'�t fTBi� STU6E ; 229/BL uP3 BW��RR DUT/Y PA St IMCB tD e�--CFN T-BN @ ..N . -H— III I I�-NEAT/BR QI.11 FIELD MIRING P9 95 P! -'-—-'—OPTIONAL MIRING AND DEVICES m IC�.i 5. 5�-COOL/BL 05 .3 5..5D —2t0VIBR— _ _ _ _ FACTORY MIRING AXD DEVICES CD �` 3 I --C2/BR 03 -3 A-D-2A0V/OK �'i D--Cl/BR Q .I 3.3� COOL r2 N-I B?-YI/T ..N o O©ir©lotQxpE3:C '2 I'�--RELD MIRIN6 t0 BE CCONPL ISNfD FOLONX6 CITT LOCL �D D— DOR NATIONAL CODES IN EFFECT AT THE TIME OF INSTALLATION OF THIS NIT j 2221R 5I1 A�II�Y2l A-IA E3a/0 2. CAUTION: LABEL ALL WIRES PA TO DISCONNECTION WHEN SERVICING CONTROLS. RING ERRORS CANN G CAUSE PROPER AND DANGEROUS A 1 • 24N/0 OPERATION F ANY OF TXE WIRING, S SUPPLIED WITH THE UNIT. 2 DLL J- I)--BLU-NHTIN 3.13 fMCB MUST BE REMOVED IT Mu3T BE REPLACED W TH TYPE 10!DEGREE I{ 600 VOLT MIRE OA EOUIVAL EXT CLEARLY RENUMBERED FOA IOLNTIICATIOX. ADJ ♦ R : {/PR 9 - xlsxLMIT ANT VERIFY PROPER OPERATION AFTER SERVICING. 77 5-IS II R e IOT/PP ROTORS ARE INHERENTLY PROTECTED. 1 B —{B3. U 1 a— }—pELAY/ A Ai ioNiiiN i[LVT a A. REMOVED O —1N0NAU~r . Se 5. REMOVED 1 DELAY 1 m.. -CI-ADJUST/PR t -T NLp[e AY C CBI a. AND UNIT NAMEPLATE FOR MAXIMUM FUSE AND/OR CIRCUIT BREAKER S.-- B - I --CFM OUT/i-BX 5-16 TI 200/R- jJt 0 MINIMUM CIRCUIL AYPAC ITY. 0 p = _ B 2 7 3^EC 3.2 AMP -- - �}-221/BR XT/W/WI P I t..,I ' C El 2.-225/PR ®9 — �R�--�cmL .. 1 FOR �y PUMP i -I -23A11 0r }i NEAT 1-- G- r2261W « 213/R CONTROL BOARD SETTINGS: 0 0 p] NP COMBUSTION BLOWER PON DELAE: JD SEC a0 �n �� INDOOR BLOWER NEAT OX DEIAY 30 SEC 8 • L 3 ,3.233IA f'-"'--}'FY^I -7—V y�T IZJ til�'205/R AL INDOOR BLOWER NEAT OFF DELAY:FIELD SELECT O �20 v. B. B� IL i' r STRAIGHT LIKE DILATES SWITCH POSITIOn 11) O IRO i PS 2AA/PR{;F-- b CFN SELECTOR BOARD "'000///��� 33' O COOLING -NOMINAL COOLING CFN Mira 3 C-SFE TECH LITERATURE 7 D-FOR ADDITIONAL INFOANATIOX ANn PI � HEATING A-NOMINAL HEATING CFM 2a5/PR�B N t�R SAD VALVE ? 2 O C- FE^ECX LITERATURE �t P A E RED PV .17 /7 D-(FOR DOITIONAI INFORMATION JN IXESENT�yJ - BLN MV 1 p 0 J ADJ: A-NOMINAL COOLING CFO r L-BLK B-NOMINAL COOLING CFO X IIOS j� CD-NOMINAL COOLING CFM X 901 Cl II S nEpE NNNOT 'I , -• J CAUTIONOPEN ALL DISCONNECTS DELAY: A•-STANDARD LU BUJ Dv/Nv BEFORE SERVICING THIS UNIT B-HUMID CLIMATE C-DRY CLIMATE Ecn 'g D•TEMPERATECLIMATE �—�—= G276392A REV E C20I/BR 1 I 3 CD I j 13 :s, I Q 3 C/S • • • E_ E I —i 3 m co o m I 0 v j o z m x o w co I A J B 1 c I D I E I F G I N 1 J 1 N I L I 0 I POWER SUPPLY 460-3-69 USE E L E M E N T A R Y D I A G R A M COOLING UNIT WITH G A S HEAT GxD COPPER CONDUCTORS ONLY ?_ I I A TEMPERATURE CONTROLS/MKT 2-STAGE UNITS TEMPERATURE CONTROLS DRNX 2-STAGE UNITS co i MI - OPEAATIN9 TEMPERATURE 70E6 P)UrtT X iE ORWPERATIM TEN/MAMIE MG F'I I (y BLU .... O 121/BX ®1{�J7 BOB1 /N uv ri slxc s in Is O I T1 O 123/BL • • nc Lss[ M 0 V el �� ��-9I I MI PxA ° 'LT. --- ; 1 WXT O i26/Y—N 1--! - ©1 I-°- N9! --- - = i o BLU .LN ASA 20 I TEL MI f C a [FMCS ia--II li :RN ODFAN •,,SA 120 I-- 1 r04 cro -- E r0-M COMP NI[COM ONO LO 2i0 - - --- i • co II 2S1/BL O®() ELF/ RAR o!0 ITO .-. .-- N!f i NI N11.G ® DM RN MO tip ,INj 232/BL P I Ell IY/Y2 1 -HA 22B`/-'BNJ LEGEND / \ CBI AUXILARCIRCUIT UNIT SWITCH 3 • CBI CIRCUIT BREAKER C LP QA TB!B NCB CFM SELECTOR BOARD c 229/BL I COXPP COMPRESSOR I7, 1 DM DRAFT MOTOR w r e p?-{FN OUT/WT-BX 1;ae INCB 1 : ; EMCB ELEC.BLOWER MOTOR CTRL.BOARD V! 6ND GROUND 0 ' IIA�I 1)--NEAT/BN �II III = SIP HIGH PRESSURE SWITCH OPENS W BOB PSIS F9 SS IDFAN INDOOR FAN MOTOR 3� 5\}-[COOL IBL �5 �5 5�5}-2/0V/BN INCB INDOOR MOTOR CONTROL BOARD CD :ill '� ]}-C2/BA _ _ _ _ LP LOW PRESSURE SWIRER O OPFxs•i PSIG /'Ni0�3 N� -24DV/BN m MS UNIT SWITCH V�CONTACTOR,COMPR. AND OD FAN f 1}-Cl/BR ( -I 3_ OMCBX OUTDOOR MOTOR CONTROL BOARD y 301 A COOL f�l 0-1.1/1 0 = IDFAN O©1ZO�O O PS RS ROLLOUT[SWNTC NH 0C 12 I)--R/R Q 12 lriyl TBI TERMINAL BLOCK I(� - TI TRANSFORMER. 21V, 46 D NEAT 2� T2 TRANSFORMER. 2{OY, leOV A �2 A— Is 222/R 0 i B mI 1}-Yi/ ,l! 23E/0 NOTES: 0 r C 24p/0 I ALL FIELD WIRING TO BE ACCOMPLISXED FOLLOWING CIAY, LOCAL I 0� 13A� I�--OLU-NXT/N �1] EBB DTOR NATIONAL CODES Ix EFFECT AT iXE TIME OF STALLATIOX (.J ADZ IS 9 OF HIS UNIT. A I IP *5 n x L M r APvr IOC/PR 2. CAUTION, LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING B !m 0-DELAY/R !m! !0 :,iw[i iORiiiiEL�1Yi CONTROLS. WIRING ERRORS CAN CAUSE PROPER AND DANGEROUS O OPERATION. If ANY Of THE WIRING. AS SUPPLIED WITH THE UNIT, UST BE REMOVED IT MUST BE REPLACED WITH TYPE 105 DEGREE C. IS" —ou[w°/m0 460v 600 VOLT WIRE OR EOUIVALEXT CLEARLY RENUMBERED FOR IDENTIFICATION. DELAY }RBI t�AOZUST/v i mi �yR C VERIFY PROPER OPERATION AFTER SERVICING. 0 2 L 67 I7--CFM OUT/Y-BN 6 r(J Ax lAM / 2lV SEC TI 200/ CR- — - '' MOTORS ARE INHERENTLY PROTECTED. 3Y �p(( REMOVED 1 R O_ 1 1 }-221IBR nT/M/WI y1 [Fort SVA .2 ANP 5. AENOVED $ R®VE Pp 2 0-225/PR —e 1 F�[f--cml 6. AEE UNIT NAMEPLATE FOR MAXIMUM FUSE AND/OR CIRCUIT BREAKER SIZE j 52 '[..{I [7 xD M1xI MUM uRculr ANPAU TY. r 7 PULAsv 1 sw -234/Y --®Y n I xGT I 215/ _.-_OPTIONALRB IRS ORB DEVICES v f i �L_ FACTORY WIRING APO j3 L 6A� -221/N VIJL_r_ r ry L J 3�-2]3/R FiI�— RB LB AL a2 ---( -t051 CONTROL BOARD SETTINGS: 5.. 3)-235/BL ,�M Il { - r�- COMBUSTION BLOWER POSTP URGE: 33 SEC 0 00 INDDOR BLOWER NEAT ON DELAY: 3D iCC Q 1 PS .3 FLAME SUM INDOOR!LOWER NEAT OFF DELAY' FIELD CSELECT O 50 GI 244/PR-0=— I n I STRAIGHT LIRE INDICATES SWITCH POSITION 0 120 a CFM SELECTOR BOARD SETTINGS //�� 0 Ip0 ;i3G MR O COOLING: 9:NOMINAL COOLING CFM iAAAsrOA I 0-(FOR ADDIITIONALA INfopMATIOX { 215lPR-{B�I D— _ HEATING: C:NOMINAL HEATING CFM iLI -, „1-E. IDOAHTLIOEAAiuORATON Mffrt«J III i ADZ. A-NOMINAL COOLING CFM kg 1--B Ln C•NOMINAL COOLING CFM N 90 Xf !A9 M PI-f usi0 i IN�L -TEL ( D-N/A CAUTION - OPEN ALL DISCONNECTS DELAY. A-STANDARD it TE x BEFORE SERVICING THIS UNIT ! -{ B•HUMID CLIMATE `-DRY LTE C r-4° G 2 7 0 3 7 f A R E V E o,D-TEMPERATE CLIMATE 301/BR A ' 0 I Q v vI .P f' 7'18444-YTG-H-0414 i Weights and Dimensions DNZJDNQ/DNX Unit Weights Unit 4 Point Load Location FRONT CENTER OF OF GRAVITY UNIT NNN 7 49-1/F3 X N.NNN NN, 7 Y 47-1/4 .77. DNZ Weights and Dimensions Model Weight(lbs.) Center of Gravity 4 Point Load Location(lbs.) (Tons) Shipping Operating X Y A B C D DNZ024 383 378 23.8 20 77 77 112 112 (2.0) DNZ030 403 398 24 20 81 81 119 117 (2.5) DNZ036 407 402 24 20 81 82 120 119 (3.0) DNZ042 465 460 22.7 21.3 105 95 124 137 (3.5) DNZ048 470 465 22.7 21.3 106 96 125 138 (4.0) DNZ060 485 480 23 21 106 99 132 142 (5.0) DNQ Weights and Dimensions Model Weight(lbs.) Center of Gravity 4 Point Load Location(lbs.) (Tons) Shipping Operating X Y A B C D DNQ024 395 390 20 24.5 113 81 82 114 (2.0) DNQ030 430 425 20 24.25 122 88 90 125 (2.5) DNQ036 435 430 20 24.25 123 89 91 127 (3.0) DN Q042 490 485 20 24 138 99 104 144 (3.5) DNQ048 495 490 20 24 139 100 105 146 (4.0) DNQ060 535 530 20 24 150 108 114 158 (5.0) 78 Johnson Controls Unitary Products ___ ._- _ ..-._... ._. .. a. ........... .............................................w.......n...nn..wrwn.n.nrawmve..nr.e.rna...rrarsexrr arrrr+rsaarrrwearxnrvsxaeusxesxrsrxudrwsucwrn3urNnrNdHRkANtN1)tADrN(ull dliN{Ysae,. 718444-YTG-H-0414 DNX Weights and Dimensions Model Weight(lbs.) Center of Gravity 4 Point Load Location(lbs.) (Tons) Shipping Operating X Y A B C D DNX024 445 440 20 24.5 127 93 93 127 (2.0) DNX036 445 440 20 24.25 126 91 93 129 (3.0) DNX048 505 500 20 24 142 102 107 149 (4.0) Johnson Controls Unitary Products 79 i 7 i 8444-YTG-H-0414 a Gas Unit Dimensions c, VENT AIR OUTLET HOOD GAS SUPPLY BLOWER SERVICE ACCESS 1-1/4"DIAMETER HOLE COMPARTMENT PANEL � CONDENSER COIL (1/2"NPTF CONNECTION) r R'GyT lire&Al UNIT CONDENSATE t Ilkn!�►�/)/J CONNECTION 3/4"NPTF ! ` �'Ij/ i3• (TRAP RECOMMENDED) \ � "�'—` i B ' o. Q . 2 3/8 HIGH VOLTAGE `I �� � c. CONN. 1-3/8"DIA. -3/, o \^ �CF'Q `� �i> 7 KNOCKOUT ik-Nkt4-, ^\''''' N. 0 0° ..�0. „0 `I r, `. REFRIGERANT 2-1/2' � CONNECTIONS GAS SUPPLY N COMBUSTION AIR ���^� INLET LOUVERS 1-1/4"DIA.KNOCKOUT '1/2"NPTF CONNECTION) ��,,`/► FRONT LOW VOLTAGE CONN.1-3/8"DIA. 1-1/2 1 / 5-3/8 GAS/ELECTRIC CONTROL KNOCKOUT x 7/8"HOLE 11 12-3/4 SERVICE ACCESS 47-1/4 �� 49-1/8 COMPARTMENT PANEL (OVERALL) (OVERALL) N 2-5/8 3-1/3 DNZ Unit Dimensions Front Unit Model Dimensions DNZ 024,030,036 33-1/2 18-1/4 DNZ 042,048,060 41-1/2 23-1/8 80 Johnson Controls Unitary Products r 718444-YTG-H-0414 ' DNQ Unit Dimensions Front Unit Model Dimensions „A„ „B„ DNQ 024,030,036 33-1/2 18-1/4 DNQ 042,048,060 41-1/2 23-1/8 DNX Unit Dimensions Unit Model Dimensions „A„ „B„ DNX 024 33-1/2 18-1/4 DNX 036,048 41-1/2 23-1/8 DNZ/DNQ/DNX Gas Unit Clearances1 2 Direction Distance Direction Distance (in.) (in.) Top' 36 Right 12 Front 36 Left 24 Rear 0 Bottom4 0 1. A 1"clearance must be provided between any combustible material and the supply air duct work. 2. The products of combustion must not be allowed to accumulate within a confined space and recirculate. 3. Units must be installed outdoors.Over hanging structure or shrubs should not obscure condenser air discharge outlet. 4. Units may be installed on combustable floors made from wood or class A,B or C roof covering materials. DNZ/DNQ/DNX Unit Accessory Weights Unit Accessory Model Weight(lbs.) Shipping Operating Add Economizer All 45 40 Unit Dimensions Front and Bottom 0 N N. ~ 19-1/4 HIGH VOLTAGE 8-7/8 11-7/8 CONN. 1-3/32" I / ' �/ DIA.KNOCKOUT ` FRONT GAS SUPPLY 1-5/8" f�� �� DIA.KNOCKOUT(1/2" .� �� �h NPTF CONNECTION) LOW VOLTAGE P�� .� ��� �N CONN.7/8"DIA. i �,;,�,,�� b I KNOCKOUT �.��. LOW VOLTAGE `; CONK.7/8"DIA. HIGH VOLTAGE , ``\�I KNOCKOUT CONN. 1-31/32"x 7/8" ��,�1 ON " 1 KNOCKOUT o t No. 40.00000,4°P 4-5/8 CONDENSATE i. o 07. DRAIN 3/4"NPTF r �r N -1/2 26-3/47 43-1/2NN>,7 22-1/2 N Z 'V Johnson Controls Unitary Products 81 r .718444-YTG-H-0414 r. Unit Dimensions Back and Bottom SIDE SUPPLY 14-1/2 AIR OPENING N. *CONDENSER 28-3/8 COIL BOTTOM SUPPLY ,�� 14-1/2 BACK AIR OPENING "0° I \� 111 3 3/8 :40Ai %��� , , \ SIDE RETURN e4 el �/� �jly# N.N.P7 '" ., AIR OPENING ro Ae4., \ V 0 'Cr we NV p A.�i/J 4 4-1/4 1 3/4 o •�I /' 15 �15., `o/ f 15 1-3l4 BOTTOM RETURN 28-9/16 3-1/ AIR OPENING 1-3/4 Unit Typical Duct Applications ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT f 1-4.‘' . I . . ,I ► ±---*- 1 1 j SLAB ON GROUND INSTALLATION i i 82 Johnson Controls Unitary Products 718444-YTG-H-0414 4- Unit Typical Slab on Ground Installation(Gas Model Shown) FIELD SUPPLIED TO POWER SUPPLY CONTROL WIRING TO DISCONNECT SWITCH INDOOR THERMOSTAT LOCATED TO REAR OF UNIT / /�/ RETURN AIR �? DUCT 0 SUPPLY AIR DUCT TO GAS 4.°.-41 SUPPLY LINE t 2411 MANUAL GAS \ \ ,�rigi %�// SHUT-OFF VALVE \\`d 00 w I. Unit Typical Roof Curb Installation(Gas Model Shown) MANUAL GAS SHUT-OFF VALVE ``' 1LP( FIELD DISCONNECT SLIED WITCHMOUNTED ON UNIT ',,,,,,,,,... . -Ns,470,0., )11k.:::::,. TO POWER uiSUPPLYliinaumgg4111111'ki door'i llii TO GAS ili'I' SUPPLY LINE CONTROL WIRING TO U INDOOR THERMOSTAT RETURN ..0 AIR DUCT SUPPLY AIR DUCT Johnson Controls Unitary Products 83 w a 18444-YTG-H-0414 i. Unit Accessory Dimensions Roof Curb1 RECOMMENDED DUCT SIZE 17-1/2"x 16-3/4" 42-3/4 45-1/8 40-3/4 17 518 ,0. 17-1/4 43-1/4 3-1/2 OPENING FOR 22 ' <: RETURN AIR DUCT 0. ..". 1%/0. 1410 '''' '1. ` OPENING FOR 1 SUPPLY AIR DUCT r ' RECOMMENDED % DUCT SIZE 14 r 17-1/8"x 21-1/2" I. 111 1. 8"Roof Curb also available. 84 Johnson Controls Unitary Products a, Roof Curb Cross Section 1„ 3/4"x 1"WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES UNIT BASE UNIT BASE RAIL WOOD NAILER P COUNTERFLASHING 8"MIN.ABOVE FINISHED ROOF 14" ; 1 CANT STRIP CURB FRAME . " INSULATION AND ROOFING MATERIAL INSULATION ROOF DECK AND ROOFING MATERIAL Subject to change without notice. Printed in U.S.A. 718444-YTG-H-0414 Copyright©2014 by Johnson Controls, Inc.All rights reserved. Supersedes:718444-YTG-G-0314 York International Corporation 5005 York Drive Norman,OK 73069