Plans Latimer HVAC CCB#220839 Outside Air Ventilation AZ RP RA VBZ EZ VOZ Natural Ventilation Room Ventilation Area Outdoor Exhaust Exhaust Area Description/n Room Area Occupant Density Factor Air Rate Breathing Zone Air Distribution Zone Outdoor Airflow Rate Airflow Yes Openings deducted Occupancy Classification Air Distribution Configuration umbers (SF) (People/1000 SF) (CFM/Person) (CFM/SF) Ventilation(CFM) Effectiveness Airflow(CFM) _ (CFM/SF) (CFM) or No (SF) (SF) Studio 1290 40 20 0.06 1109.4 0.8 0 0_ Yes 63 1290 Health club/aerobics room Ceiling supply and ceiling return office 160 5 5 0.06 13.6 0.8 17 0 No Office space Ceiling supply and ceiling return restroom 50 0 0 0 0 0.8 0 70 80 No Toilet room-public Ceiling supply and ceiling return RTU1 1500 _ OSA required 20 OSA provided 200 exh prov 80 -Le:end atimer HVAC RECEIVED M1, Eli - Supply Diffuser HEATING•VENTILATION•AIR CONDITIONING AUG 19 2021 Scope of Work 0 - Return Grill CITY OF TIGARL BUILDING DIVISION Latimer HVAC will perform the following scope of work: 0 i - Thermostat 1. Provide (1)ceiling mount exhaust fan for restroom. 2. Ducting and air distribution mods as drawn. 0 . ; Olifti 0 - Exhaust fan -C3 cc Equipment Schedule co RTU1-. Existing 4-ton gaspack. Nominal 1600 cfm. - E: cc EF1- Panasonic FV05-11-80 cfm @ 0.25sp. On switch. Ci.j - Existing 1 p .. O Neck size/ CFM CID Mechanical General Notes: '2..c)c> _ v ~ 1. All steel ducting will be 26 ga minimum galvanized. Flex per Mfg. 2. Ducting in Attic-provide all R-8 insulation. "- - Volume dampers tri 3. Heating and cooling ducting to be designed to not exceed 0.5 wc positive (supply) and 0.5 wc negativei r--1 (return). 4. Provide programmable thermostat. 5 degree deadband minimum.7 day. Microprocessor.Set program for Project Name: WILLOWBROOK B1 TI night energy savings. Project Number: 5. Seal ducting with UL listed mastic or mastic tape. Architects/Engineers Action on this Submittal: X NO EXCEPTIONS TAKEN REVISE& RESUBMIT Ventilation Requirements-based on 2019 OMSC table 403.3 EXCEPTIONS AS NOTED _ REJECTED Review is limited to checking for conformance with the information liven and the design 'i. concept expressed in the contract documents. The Contractor and/or Construction Manager remains totally responsible for all dimensions,quantities,construction methods and means,techniques,sequences in the work,and procedures. RTU1- SA= 1600 cfm V4 rf ■ OF TIGARD Signed:Melynda Retallack,Ink Built Architecture RA=1400 cfmDate_I'. 21 OSA=200 cfm Approved PLE/� VE THE OWNER REVIEW THE LAYOUT TO Contitionatly Approved ORKS PER THEIR LEASE. For only the work as descri�i PERMIT NO.rhL �t �7 `` See Letter to: Follow ea Attach M ® •O By: > Job Address: 1/s- , sa � d .v ,�, !�'Y • �'. 2 f- Date: 1' r )-I 7r�,- T 1 Latimer 1-IVAC CCB#220839 IN' . 0927 q 41 i SOO .R dm0•1•2 .. -od ---- 4 L._,..11 / 1 i 0 , .,.....1.1LA: , I 1 11 n }"fmallarjHr. a 'i I1 rn 1,04`' _., __. I 1 it IX i , CLI ..... . _ 1.-1-R1 0 ftS 0 SI = i.-_- , CI rO I // V Lan 6t d o, f.At / r-1 1r—I J ' //` / I , 1 IVAI,/ RAO 1.4 tki, 1 Ili M k i i fa 0 . Whi erCeiling•DC- ECELVEk, FV-0511VQ1 VENTILATION FAN Specification Submittal Data /Panasonic Precisit5r�Spot ve" ntilation Fan 4"or 6"Duct ,A�TTVV((}} ``.,hFl Description: Ceiling Radi idnifhihiPdH rl ,; Ventilating fan shall be Low Noise ceiling mount •WhisperCeitl � ll[ai ��l® a /+ � , 4. , I'` it�` 1 type rated for continuous run.Fan shall be with the Panasonic Ceiling Radiation Damper tee,..-- ENERGY STAR®rated and certified by the (Model#;PC-RDO5C5,sold separately). �' Home Ventilation Institute(HVI).Evaluated by �e ^� � �` Underwriters Laboratories and conform to both Grille. �.g P ,°,>q i o e UL and cUL safety standards. •Attractive design using Poly Pro material. •Attachesprings. directly to housing with torsion ��1�� Motor/Blower: springs. •Enclosed brushless ECM motor technology Warranty: rated for continuous run. •ECM Motor:6 Years from original purchase ��•� •Fan ventilation rates shall be manually date. FV-0511VQ1 adjustable for 50-80-110 CFM. •ALL Parts:3 Years from original purchase •Power rating shall be 120 volts and 60 Hz. date. •Fan shall be UL and cUL listed for tub/ run continuously.ECM motor speed shower enclosure when GFCIprotected. Architectural shall automatically increase when the Specifications: fan senses static pressure to maintain •Motor equipped with thermal-cutoff fuse. Ventilation fan shall be UL and cUL listed for selected CFM.Power rating shall be •Removable with permanently lubricated plug- ceiling mount and tub/shower enclosure when 120V/60Hz.Duct diameter shall be no in motor. GFCI protected.Fan shall also be ENERGY less than 4",inclusive of an integrated Housing: STAR®certified,with a built-in speed selector. dual 4"or 6"duct adapter.Fan can be Choose from 50-80-110 CFM and no more •26 gauge Zinc-Aluminum-Magnesium(ZAM) used to comply with ASHRAE 62.2, housing than<0.3/<0.3/<0.3 sone as certified by the LEED,ENERGY STAR®IAP,EarthCraft, •Integrated dual 4"or 6"diameter duct Home Ventilating Institute(HVI)at 0.1 static CA Title 24 and WA state code. adapter. pressure in inches water gauge(w.g.)with •Built-in damper reduces back drafting and no less than 53 83 111 CFM and no more helps with blower door testing. than 0.4/0.6/0.9 sone as certified by HVI at •Built-in metal flange provides blocking for 0.25 w.g.Power Consumption shall be no w.g. penetrations through drywall as an Air Barrier, greater than 4.0/5.9/10.6 watts at 0.1 with and assists with the decrease in leakage in the and efficiency of7.2/10.8/16.4 watts at 0.25 w.g.,with Building Envelope during blower door testing. no less than 12.5/13.6/10.6 CFM/ •Articulating and expandable installation watt at 0.1 w.g.and 7.4/7.7/6.9 CFM/watt at bracket up to 24". 0.25 w.g.The motor shall be totally enclosed with a brushless ECM motor engineered to Performance Curve 4" Duct Specifications:WhisperCeiling DC FV-0511VQ1 4° 4" 4° °° Static Pressure in inches w.g. 0.1 ® 0.1 El 0.1 ® om Air Volume(CFM) 110 111 80 83 50 53 b ,.,0511,01 Noise(sons) <0.3 0.9 <0.3 0.6 <0.3 0.4 __e0cr„ s Ventilation Fan Power Consumption(watts) 10.6 16.4 5.9 10.8 4.0 7.2 °AO Characteristics Energy Efficiency(CFMANatt) 10.6 6.9 13.6 7.7 12.5 7.4 °3D (HVI Certified Speed(RPM) 957 1239 821 1172 756 1093 I / :` F 4.40e Data) Current(amps) 0,18 0.26 0.11 0.18 007 0.13 oso 7' AMom MAX.Current(amps) 0.27 ,j / -- Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0 10 20 90 40 SO 90 70 e0 e0 100 110 120 0.25=Installed Performance Airflow PR18 For complete Installation Instructions visit us.panasonic.com/ventfans Model Quantity Comments Project: Location: Architect: .. Engineer: Contractor: Submitted by: Date: Panasonic Eco Solutions North America ,ktPµT F�o, ECM Motor Technology Eco Products Division ;.:. When the fan senses static pressure,its speed is automatically increased to ensure Two Riverfront Plaza Newark,NJ 07102 jFcN�oo� that the desired CFM is not compromised,which allows the fan to perform as rated. us.panasonic.com/ventfans �e MeeEtficient Panasonic Nvi �®ut 2017' ceenne° VF17564SS0917