Loading...
Plans (2) I 2 "TRILLIUM HILL" LOT 12f yrS C �-r�q HUB AND TACK CERTIFICATION ��} SE 1/4 SEC. 10, T 2 S, R 1 W, W.M. 0�'7S_ 2,Z/-cV/1� CITY OF TIGARD, WASHINGTON COUNTY, OREGON SURVEYED JULY 12, 2021 I I ' I I I I I I PREPARED FOR: ( ( ( 7 6 DAVID WEEKLEY HOMES 1905 NW 169TH PLACE, SUITE 210 ( ,\\ BEAVERTON, OR. 97006 1 1 �� 1 a- I I I I PUBLIC SIDEWALK TRACT 'A' I I o I II EASEMENT I 1 w SW TIERRA TERRACE T 1 I Ico II { N89'S3'03”E 73.64' I SP +.�. _I-- A I v a N I . I PUBLIC UTILITY * 1 i ci o Q1 N 5.00'-- .- --- 8.64' a11 3 12 W I 13 a !) to ° o 0 0 0 u Z V) STORM DRAINAGE i PRIVATE WALL �( EASEMENT MAINTENANCE EASEMENT } --f N _ CD 0 (0 _O • �T Qj - - O_ - - 6i_ - CO . 1- + 1 \ E REGISTERED 1 S89'52'46"W 73.64' PROFESSIONAL P LAND SURVEYOR TRACT 'B' NI O rI co < OREGON / 1 G/ i JAN. 14, 2020 NICK A. LAFOND \, 93484PLS CD RENEWS: 12/31/2022 °' I, NICK A. LAFOND, A REGISTERED PROFESSIONAL LAND SCALE t SURVEYOR IN THE STATE OF OREGON, HEREBY CERTIFY THAT 30 0 15 30 cl I HAVE ACCURATELY SURVEYED AND STAKED THE t InIIIImisi � a FOUNDATION FOR LOT 12 OF "TRILLIUM HILL". 1 INCH = 30 FEET 0 0 s� DRAWN BY: JRH DATE: 7/14/21 PACIFIC COMMUNITY DESIGN a REVIEWED BY: T2 DATE: 7/14/21 Z 130-002 PLANNING - ENGINEERING - SURVEYING PROJECT NO.: (503) 941-9484 GEEJPRCIFIC Real-World Geotechnical Solutions Investigation • Design•Construction Support July 19, 2021 Project No. 18-5046 David Weekly Homes 1905 NW 169th Place, Suite 102 Beaverton, Oregon 97006 Phone: 503-213-4408 Email: dmillermoylanta@dwhomes.com FOUNDATION SUBGRADE REVIEW LOT 12—TRILLIUM HILL TIGARD, OREGON This letter addresses the single-family home foundation subgrade on Lot 12. We understand that the proposed building is a two-story home with a crawl space. As part of this evaluation, GeoPacific visited the site last week and today to observe the subgrade foundation preparation. At the time of our site visits, the foundation excavation was complete and extended approximately 6 to 24 inches below existing ground surface. The foundation bearing soils appeared to consist of compacted fill soils. Probing efforts with a I/2-inch soil probe resulted in 1 to 2 inches of penetration into the subgrade fill indicating medium stiff to very stiff consistency. The layout of Lot 12 has slope descending toward the rear of the lot. Footing-to-wall and footing-to-slope setbacks appeared to be adequate based on the anticipated layout. Based on observed conditions, foundation subgrades as prepared are considered suitable to support the planned allowable bearing pressure of 1,500 psf. Estimated settlement under the allowable bearing pressure is 1-inch total, and 3/4 inch differential, measured over a horizontal distance of 20 feet. Care should be taken to avoid saturation or disturbance of footing subgrade soils during and after excavation. If footing bearing soils become saturated or disturbed, any softened soil or slough should be removed and replaced with crushed aggregate or additional concrete. In general, footing excavations should be cleaned such that no more than approximately 1/2-inch of loose soils are present prior to pouring concrete. Construction should include typical measures for controlling subsurface water beneath the homes, including positive crawlspace drainage to an adequate low-point drain exiting the foundation, visqueen covering the exposed ground in the crawlspace, and crawlspace ventilation (foundation vents). The homebuyers should be informed and educated that some slow flowing water in the crawlspaces is considered normal and not necessarily detrimental to the home given these other design elements incorporated into its construction. Adequate crawlspace drainage is not something that geotechnical consultants can verify; the purpose of our visit is for observations of foundation bearing conditions only. Appropriate design professionals should be consulted regarding crawlspace ventilation, building material selection and mold prevention issues, which are outside GeoPacific's area of expertise. 14835 SW 72nd Avenue Tel(503)598-8445 Portland,Oregon 97224 Fax(503)941-9281 GEOPACIFIC Job No. 18-5046 Lot 12 Trillium Hill We have prepared this report for Stonebridge Homes, and it should not be relied upon by third parties without consulting GeoPacific. Within the limitations of scope, schedule and budget, GeoPacific attempted to execute these services in accordance with generally accepted professional principles and practices in the fields of geotechnical engineering and engineering geology at the time the report was prepared. The conclusions and interpretations presented in this report should not be construed as a warranty of the subsurface conditions. No warranty, expressed or implied, is made. The scope of our work did not include flood hazard evaluations, environmental assessments, the presence or absence of wetlands; or potential hazardous substances in the soil, surface water, or groundwater at this site. We appreciate this opportunity to be of service. Sincerely, GEOPACIFIC ENGINEERING, INC. OR°D PRO k5\y • NAG,N EF'P 0 /02 14743PE f / OREGON �9Ni•23,ig9( DES b iM0 EXPIRES:06/30120 23 James D. Imbrie, G.E. Geotechnical Engineer