Loading...
Report CT ENGINEERING of IN C 1 �O 180 Nickerson St. Suite 302 Seattle,WA 98109 1 (206)285-4512(V) (206)285-0618(F) asolomon(actengineering.com BULLETIN Date: July 16,2021 Number: CT-104 Project#: 15238 Project Name: River Terrace SF Attached: CT-104.1 Subject: Plans 222100B (Lot 153) & lA (Lot 154)— Foundation for Braced Wall Panel @ Garage Drawings Affected: Detail 19/S1.2 (Braced Wall Panel Adjacent to Garage Door) Description/Action: This bulletin provides response to RFI's, design clarifications and/or variation requests for the `River Terrace SF' project located in Tigard, Oregon. Per our discussion with Taylor Morrison, it's our understanding that for the two lots/plan types noted above, the concrete stem walls for the garage braced wall panels were poured 1'-0"+/-too low. See attached detail CT-104.1 for an appropriate fix. SIF,uCTUR4, PROA, 0 g �p G0o< ) '6' F• . oc6v 07/16/2021 CALL WITH ANY QUESTIONS Issued by: Arnold R. Solomon Date: July 16, 2021 Distribution: Contact Information: Dennis Gaudreault Taylor Morrison Frank Sandoval Taylor Morrison Sam Scott Taylor Morrison Amy Russell Taylor Morrison Elizabeth Erlandson Milbrandt Architects R:\15238 River Terrace SF\Bulletins\15238_2021.07.16_CT104_Plans 222100E(Lot 153)&1A(Lot 154)_Foundation for Braced Wall Panel @ Garage.doc Structural Engineers 180 Nickerson St. CT ENGINEERING Suite 302 RIVER TERRACE srSeattle,WA Project 07/16/2021 98" Date: (206i 285-4512 Client: TAYLOR MORRISON CT-104.1 F.�k_ Page Number: 12061 285-0618 CT-104 BULLETIN ADO (.L k ° r mw, o FOR EVERY #4 VERT BAR, I ADD (1) #4 VERT (DRILL & I I o EPDXY USING 'SIMPSON STRONG-TIE SET-3G' I ANCHORING ADHESIVE P SYSTEM OR APPROVED EQUAL -- MIN. EMBED OF WA DEPTH = 4-1/2") REInF 'PM lila b.)$T Coy(, \?1 , WALL. g9` Structural Engineers