Report CT ENGINEERING of
IN C 1 �O 180 Nickerson St.
Suite 302
Seattle,WA 98109
1 (206)285-4512(V)
(206)285-0618(F)
asolomon(actengineering.com
BULLETIN
Date: July 16,2021 Number: CT-104 Project#: 15238
Project Name: River Terrace SF Attached: CT-104.1
Subject: Plans 222100B (Lot 153) & lA (Lot 154)— Foundation for Braced Wall
Panel @ Garage
Drawings Affected: Detail 19/S1.2 (Braced Wall Panel Adjacent to Garage Door)
Description/Action:
This bulletin provides response to RFI's, design clarifications and/or variation requests for the `River
Terrace SF' project located in Tigard, Oregon.
Per our discussion with Taylor Morrison, it's our understanding that for the two lots/plan types noted
above, the concrete stem walls for the garage braced wall panels were poured 1'-0"+/-too low. See
attached detail CT-104.1 for an appropriate fix.
SIF,uCTUR4,
PROA,
0 g
�p G0o< )
'6' F• . oc6v
07/16/2021
CALL WITH ANY QUESTIONS
Issued by: Arnold R. Solomon Date: July 16, 2021
Distribution:
Contact Information:
Dennis Gaudreault Taylor Morrison
Frank Sandoval Taylor Morrison
Sam Scott Taylor Morrison
Amy Russell Taylor Morrison
Elizabeth Erlandson Milbrandt Architects
R:\15238 River Terrace SF\Bulletins\15238_2021.07.16_CT104_Plans 222100E(Lot 153)&1A(Lot 154)_Foundation for Braced Wall
Panel @ Garage.doc
Structural Engineers
180 Nickerson St.
CT ENGINEERING Suite 302
RIVER TERRACE srSeattle,WA
Project
07/16/2021 98"
Date:
(206i 285-4512
Client: TAYLOR MORRISON CT-104.1 F.�k_
Page Number: 12061 285-0618
CT-104 BULLETIN
ADO (.L k ° r mw,
o
FOR EVERY #4 VERT BAR, I
ADD (1) #4 VERT (DRILL & I I o
EPDXY USING 'SIMPSON
STRONG-TIE SET-3G' I
ANCHORING ADHESIVE P
SYSTEM OR APPROVED
EQUAL -- MIN. EMBED OF WA
DEPTH = 4-1/2")
REInF
'PM lila
b.)$T Coy(,
\?1 , WALL.
g9`
Structural Engineers