Report CT ENGINEERING
INC ✓ 0o0b0 180 Nickerson St.
U) 00 Suite 302
a' Seattle,WA 98109
(206)285-4512(V)
(206)285-0618(F)
asolonion@ctengineering.com
BULLETIN
Date: June 21, 2021 Number: CT-102 Project#: 15238
Project Name: River Terrace SF Attached: CT-102.1
Subject: Plans 222300G (L 155 & 3410B (Lot 241)—Foundation for Braced Wall
Panel @ Garage
Drawings Affected: Detail 19/S1.2 (Braced Wall Panel Adjacent to Garage Door)
Description/Action: '
This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River
Terrace SF' project located in Tigard, Oregon.
Per our discussion with Taylor Morrison, it's our understanding that for the two lots/plan types noted
above, the concrete stem walls for the garage braced wall panels were poured 1'-4"+/-too low. See
attached detail CT-102.1 for an appropriate fix.
SlRUCT(IR,44
Ep PROF
�\G I NF
tz
0 ONy )
q/c •F12, 'R)\-
06/21/2021
CALL WITH ANY QUESTIONS
Issued by: Arnold R. Solomon Date: June 21, 2021
Distribution:
Contact Information:
Dennis Gaudreault Taylor Morrison
Frank Sandoval Taylor Morrison
Sam Scott Taylor Morrison
Amy Russell Taylor Morrison
Elizabeth Erlandson Milbrandt Architects
R:115238 River Terrace SF\Bulletins\15238_2021.06.21_CT102_Plans 222300G(Lot 155)&3410B(Lot 241)_Foundation for Braced Wall
Panel @ Garage.doc
Structural Engineers
C T ENGINEERING 180 Nickerson St.
Suite 302
RIVER TERRACE srC Seattle,INA
Project: 06/21/2021 98109
Date:
TAYLOR MORRISON (206)285-4512
Client CT-102.1 FAX:
Page Number: (206)285-0618
CT-102 BULLETIN
D (7.141 ° 1a,t,),
I � i
FOR EVERY #4 VERT BAR, Cb
ADD (1) #4 VERT (DRILL & t
EPDXY USING 'SIMPSON ` ,
STRONG-TIE SET-3G' P —`
ANCHORING ADHESIVE I
SYSTEM OR APPROVED I I
EQUAL -- MIN. EMBED I F OF ,YrR
DEPTH = 4-1/2")
ST 11,Elf\F
Perk 190.2,
ho sT C4rs,
Ia ot,
Structural Engineers